Loading...
Report (28) Fire Marshal's Offices - \�1� ., IVELNorth Division- 14480 SW Jenkins Rd.,Beaverton,OR 97005•PH(503)356-4700•Fax(503)644-2214 Tualatin Valley South Division-7401 SW Washo Ct.,Ste. 101,Tualatin,OR 97062•PH(503)612-7000•Fax(503)612-7003 Fire & Rescue Z Z Z Z Z Z J J -1 J J J CC CC CC a' CC CC DDDDDD Building Survey Report m ac m m m wwwwww FMZ : (to be filled out by TVF&R) Code Edition: 98OSSC Z Z z Z z z U V U U o o Name of Facility: Canterbury Woods LP U) U) 3 Name of Building: Carriage Buildings, Buildings 1,2,3,5,6 & 7 00 0o 0o 0o 00 co N u') M ei o o o 0 o ,- o c-1 t--1 ,-1 e-1 .--1 c-1 Address: SA rn o V) CO 0 Owner: Polygon Northwest Telephone No. (360) 695-7700 0 ((--. N N N N 0 0 0 0 N Architect: Leonard j. Milbrandt Te9 0 0 0 0 0 lephone No. (425) 454-7130 0 0 0 0 0 0 0 0 0 0 0 0 Architect Address: N N N N N N a a a a a a ODDODO m m m m m m :� ;ITEM m r-1 N M Lf) LO r, "' COMM: yriSCRIETIOX:, I. Occupancy Type R1 I Use 6 unit condo Capacity None 2. Construction Type V-1 hr Year Built 3. Area(Sq.Ft.) Total 7748 Largest Floor 2 g Basement None 4. Stories No 2 Height 28'-5" High Rise DY ®N 5 a. Exterior Wall Construction WF-1 h r b. Opening Protection None 6. Interior Wall Construction GB on WF/GB on WT 7. Floor Construction Carpet-CD-Ply-WGL-GB-GB/1 hr 8. Roof Construction Class "C" RS-Roof felt-Ply-WT @ 24" o.c. 9. Attic Draft Stops No. Yes-4 1/2" GB-WT 10a. Occ. Sep. Wall Construction No. Yes-4 GB-WF-Insulation-Airspace-WF-GB b. Opening Protection None 11a. Fire Wall Construction No.None PER 98OSSC I b. Opening Protection None 12a. Smoke Barrier Wall Construction No. None b. Opening Protection None J 13a. Corridor Wall Construction None b. Opening Protection None 14a. Corridor Ceiling Construction None b. Opening Protection None 15a. Shafts No. 4 I Type Dryer vent I GB-WF 1 hr b. Opening Protection UL Fire caulk Buildinq Survey Report FMZ : (to be filled out by TVF&R) Name of Facility: Carriage Buildings, Buildings 1 ,2,3,5,6 & 7 TTElYI Comm, DESCRIPTION 16a. Stair Enclosure No. None b. Opening Protection DF 17. Stairs No. 4 18. Ramps No. None 19. Interior Finish Class Room None Exit Enclosure Corridor 20. Exits No. 6 Total WidthNone per 98OSSC 21. Exit Hardware Type Knob 22a. Exit Signs/Illumination None b. Emergency Lighting None 23. Auto Sprinkler Coverage Yes-P 24. Standpipe Class/Locations None 25. Fire Alarm Type/Coverage Yes- 26. Heating,Ventilation&Air Conditioning Type Unit heat Fuel Electric 27. Electrical Installation Romex-Circuit breaker 28. Stage/Platform None 29. Hazardous Area None 30. Other Comments: Alternate Materials&Methods TVF&R Use Only Inspected By: Date No.Attachments Reviewed By: Date Updated