Name of Facility: Canterbury Woods U) U) U) U) U) U)
Name of Building: Carriage Buildings, Buildings 1 ,2,3,5,6 & 7 co 0 0`00 0"o coo 000
0 0 0 0 0 0
Address: SA
rn o CO 0
Owner: Polygon Northwest N r, 00 00 00 cmTelephone No. (360) 695-7700 0 0 0 0 0 0
0 0 0 0 0 0
Architect: Leonard.). Milbrandt Telephone No. (425) 454-7130 0 0 0 0 0 0
0 0 0 0 0
Architect Address: Ni N N Ni N N
a a a a a a
DDDDOD
m m m m m
r-1 N M n
COMM OESCRIPTAON,
1. Occupancy Type R1 Use 6 unit condo Capacity None
2. Construction Type V-1 hr Year Built
3. Area(Sq.Ft.) Total 7748 Largest Floor 2 Basement None
4. Stories No 2 Height 28'-5" High Rise DY ®N
5 a. Exterior Wall Construction WF-1 hr
b. Opening Protection None
6. Interior Wall Construction GB on WF/GB on WT
7. Floor Construction Carpet-CD-Ply-WGL-GB-GB/1 hr
8. Roof Construction Class "C" RS-Roof felt-Ply-WT @ 24" o.c.
9. Attic Draft Stops No. Yes-4 1/2" GB-WT •
10a. Occ.Sep.Wall Construction No. Yes-4 GB-WF-Insulation-Airspace-WF-GB
b. Opening Protection None
l la. Fire Wall Construction No.None PER 98OSSC
b. Opening Protection None
12a. Smoke Barrier Wall Construction No. None
b. Opening Protection None
13a. Corridor Wall Construction None
b. Opening Protection None
14a. Corridor Ceiling Construction None
b. Opening Protection None
15a. Shafts No. 4 I Type Dryer vent I GB-WF 1 hr
b. Opening Protection UL Fire caulk
Building Survey Report
FMZ : (to be filled out by TVF&R)
Name of Facility: Carriage Buildings, Buildings 1 ,2,3,5,6 & 7
r . ,
ITEM- COMM. DESCRIPTION
16a. Stair Enclosure No. None
b. Opening Protection DF
17. Stairs No. 4
18. Ramps No. None
19. Interior Finish Class Room None Exit Enclosure Corridor
20. Exits No. 6 Total WidthNone
per 98OSSC
21. Exit Hardware Type Knob
22a. Exit Signs/Illumination None
b. Emergency Lighting None
23. Auto Sprinkler Coverage Yes-P
24. Standpipe Class/Locations None
25. Fire Alarm Type/Coverage Yes-
26. Heating,Ventilation&Air Conditioning Type Unit heat Fuel Electric
27. Electrical Installation Romex-Circuit breaker
28. Stage/Platform None
29. Hazardous Area None
30. Other