Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (8)
RECEIVED JUN l b 2016 CITY OF TIGARD ,•, ,., BUILDING DIVISION (#14?6\44, WYAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 SANDBURG CENTER 6825 SW SANDBURG STREET TIGARD, OREGON 97223 City of Tigard Ap s r.ve. Plans By PM- OFFICE pateIL OFFICE COPY FIRE PROTECTION EQUIPMENT SUBMITTAL tycciWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage 4. General NOTICE The TYCO Series TY-FRB Sprinklers f Description described herein must be installed and maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright (TY313)and Pendent (TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition tothe stan- • are quick response,standard coverage, dards of any other authorities having ' i decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair '' sprinklers designed for use in light or the performance of these devices. l ; �" ' ` ordinary hazard,commercial occupan- cies such as banks, hotels, and shop The owner is responsible for maintain- * 6 in their fire rotection system and ` ping malls. 9 P Y devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble,ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent ,.' i sprinkler uses one of the following: • A two-piece Style 15 Recessed Sprinkler M_'' ' Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm)from .. x,',, the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) 175°F(79°C) Intermediate level versions of Series AUL and C-UL Listed rovals 200°F 93°C) TY-FRB Sprinklers are described in 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psit12(80,6 LPM/barv2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I r,...... 111 1 --- / 5 =! 7/16" Y 1 R_ _ (11,1 mm) I } I�1 4 NOMINAL � 2" MAKE-IN (50,8 mm) I 2 INV . . aillimr 3 p' a 2' 1 1-3/8" 4 Iv (50,8 mm) (34,9 mm) WREN / lir CH 1 if G / 1 FLATS 1/2" NPT** DEFLECTOR* �— 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation WRENCH RECESS The glass bulb contains a fluid which The TYCO Series TY FRB,5.6 K factor, expands when exposed to heat.When Upright(TY313)and Pendent(TY323) ,....../"."-. (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air WRENCH bub- Criteria ble should be present. The diameter of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. - � 1� tion systems designed in accordance with the standard installation rules rec- ognizedAll by the applicable Listing or should be obtained by applying a min- Approval agency (such as, UL Listing imum to maximum torque of 7 to 14 - �• is based on the requirements of NFPA ft. lbs. (9,5 to 19,0 Nm). Higher levels %...., 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) — Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers 1 \ _ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" —1 I I ANI must be installed in accor- (9,5±7,9 mm) s r3 dance with the following instructions. } / Step A.After installing the Style 15 or MOUNTING WI 1/8" J I - Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread --_---— sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE - sprinkler fitting. 3/4"(19,1 mm) Step B. Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the W-Type SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) spriWITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench(Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) — Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER ____ 2-1/4"DIA. fishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" 1/2 (12,7mm) kler and push the Closure over the (7,9±6,4 mm) Mounting Plate until its flange comes in + FLUSH contact with the ceiling. j = =1 I ,,, + Care and f I ` MOUNTING j 1/8" Maintenance SURFACE - (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, -" 1 Upright(TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) - Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) y main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad cracked bulb or that has lost liquid from vertent operation may result. its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX � I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)°° 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2"NPT) TY323 4 SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F93°C for example,77-370-4-175-I ( ) "Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish,P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish, P/N(specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. tgcc TEFLON is trademark of The DuPont Corporation. '7 Fire Protection Products tqcoWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB — 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General tained when exposed to corrosive at- mospheres. Although corrosion resis- .; Descri tion tant coated sprinklers have passed the p standard corrosion tests of the appli- The Series TY-FRB, 5.6 K-factor, Hor cable approval agencies,the testing is izontal and Vertical Sidewall Sprin not representative of all possible cor- "' �, .._ • klers described in this data sheet rosive atmospheres. Consequently, it I are quick response standard cover- is recommended that the end user be age, decorative 3 mm glass bulb type consulted with respect to the suitabil- i ' A4S., spray sprinklers designed for use in ity of these coatings for any given cor- light and ordinary hazard, commer- rosive environment.The effects of am- cial occupancies such as banks, ho- bient temperature, concentration of ,/ , tels,shopping malls, etc.They are de- chemicals, and gas/chemical velocity, /, signed for installation along a wall or should be considered, as a minimum, the side of a beam and just beneath a along with the corrosive nature of the smooth ceiling.Sidewall sprinklers are chemical to which the sprinklers will commonly used instead of pendent or be exposed. upright sprinklers due to aesthetics or NOTICE building construction considerations, where piping across the ceiling is not The Series TY-FRB Sprinklers de- ' desirable. scribed herein must be installed and The recessed version of the Series maintained in compliance with this TY FRB Horizontal Sidewall Sprin document, as well as with the appli- kler is intended for use in areas with cable standards of the National Fire a finished wall. It uses a two-piece Protection Association, in addition to Style 10 Recessed Escutcheon with the standards of any other authorities havingjurisdiction. Failure to do so *^ 1/2 inch(12,7 mm)of recessed adjust- _. merit or up to 3/4 inch(19,1 mm)of to- may impair the performance of these _ tal adjustment from the flush sidewall devices. position, or a two-piece Style 20 Re- The owner is responsible for main- cessed Escutcheon with 1/4 inch (6,4 taming their fire protection system p p ro er pe a ng con ..- mm) of recessed adjustment or up to and devices in o r ti - '.' 1/2 inch (12,7 mm)of total adjustment dition. Contact the installing contrac- from the flush sidewall position. The tor or sprinkler manufacturer with any adjustment provided by the Recessed questions. Technical Escutcheon reduces the accuracy to which the fixed pipe nipples to the Sprinkler Data sprinklers must be cut. Corrosion resistant coatings, where Identification Approvals applicable, are utilized to extend the UL and C-UL Listed. life of copper alloy sprinklers beyond Numbers FM, LPCB,and NYC Approved. that which would otherwise be ob- (Refer to Table A for complete approv- TY3331 Horizontal al information including corrosion re- TY3431 Vertical sistant status.) IMPORTANT Always refer to Technical Data Maximum Working Pressure Sheet TFP700 for the "INSTALLER Refer to Table B. WARNING" that provides cau- Discharge Coefficient tions with respect to handling K-5.6 GPM/psi1/2(80,6 LPM/bar1/2) and installation of sprinkler sys- tems and components. Improp- Temperature Ratings er handling and installation can Refer to Table A. permanently damage a sprin- Finishes kler system or its components Sprinkler: Refer to Table C. and cause the sprinkler to fail Recessed Escutcheon:Signal or Pure to operate in a fire situation or cause White,Jet Black,Chrome Plated,or it to operate prematurely. Brass Plated. Page 1 of 6 FEBRUARY 2014 TFP176 TFP176 Page 2 of 6 DEFLECTOR Installation 1 - Frame 2 Button HAT 5 �AVA9A d►� The Series TY-FRB,5.6 K-factor, Hori- 3 - Sealing fit zontal and Vertical Sidewall Sprinklers Assembly must be installed in accordance with 4 Bulb / �,�� this section. 5 Compression General Instructions Screw 6 - Deflector* 6*/ 4 2 3 1 Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the 9/16" WRENCH 1/2"** sprinkler held horizontally, a small air (14,3 mm) FLATS NPT bubble should be present. The diam- 1 eter of the air bubble is approximately 1/16 inch(1,6 mm)for the 135°F(57°C) �1� / �� to 3/32 inch (2,4 mm) for the 286°F -�f =O= II� I (141°C)temperature ratings. �'+ = A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 1-13/16" 7/16" to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher (46,0 mm)— (11 1 mm) levels of torque may distort the sprin- NOMINAL `— kler and cause leakage or impairment CENTERLINE MAKE-IN of the sprinkler. OF SPRINKLER WATERWAY 1 1/2„ Do not attempt to make-up for insuf- ficient adjustment in the escutcheon `—(38,1 mm)~ plate by under-or over-tightening the *Temperature rating sprinkler. Readjust the position of the is indicated on �_ 2-3/16" sprinkler fitting to suit. Deflector. (55,6 mm) ESCUTCHEON Series TY-FRB Horizontal and ** STYLE Vertical Sidewall S rinkler Pipe thread $ 10 or 20 PLATE SEATING P connections per RECESSED SURFACE Installation ISO 7-1 can be ESCUTCHEON I • The Series TY-FRB Horizontal and provided on Vertical Sidewall Sprinklers must be special request. �� installed in accordance with the fol- _,1 lowing instructions. 2-7/8"DIA. �i��!rirlllllllllllll (73,0 ) Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal po- sition with their centerline of waterway perpendicular to the back wall and parallel to the ceiling.The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be FIGURE 1 installed in the pendent or upright po- 5.6 K-FACTOR QUICK RESPONSE sition with the arrow on the Deflector SERIES TY-FRB HORIZONTAL SIDEWALL(TY3331)SPRINKLERS pointing away from the wall. Characteristics Step 2. With pipe thread sealant ap- PhysicalDesign plied to the pipe threads, hand tighten Frame Bronze the sprinkler into the sprinkler fitting. Button Brass/Copper Criteria Sealing Assembly Beryllium Nickel w/ Step 3. Tighten the sprinkler into the TEFLON The Series TY FRB,5.6 K-factor, Hori sprinkler fitting using only the W- Type Bulb Glass zontal and Vertical Sidewall Sprinklers 6 Sprinkler Wrench (Ref. Figure 5), Compression Screw Bronzei Wth reference to Figure 1 or 2,the W- HSW Deflector Bronze are intended for fire protection sys- Type 6 Sprinkler Wrench is to be ap- VSW Deflector Copper tems designed in accordance with the plied to the wrench flats. standard installation rules recognized Operation by the applicable Listing or Approval agency (e.g., UL Listing is based on The glass bulb contains a fluid which the requirements of NFPA 13, and FM expands when exposed to heat.When Approval is based on the requirements the rated temperature is reached, the of FM's Loss Prevention Data Sheets). fluid expands sufficiently to shatter Only the Style 10 or 20 Recessed Es- the glass bulb, allowing the sprinkler cutcheon, as applicable, is to be used to activate and water to flow. for recessed horizontal installations. TFP176 Page 3 of 6 Series TY-FRB Recessed *Temperature ** Pipe thread 1 - Frame 4 - Bulb 7 - Ejection Horizontal Sidewall Sprinkler rating is connections 2 - Button 5 - Compression Spring Installation indicated on per ISO 7-1 can 3 - Sealing Screw The Series TY-FRB Recessed Hori- Deflector. be provided on Assembly 6 - Deflector* zontal Sidewall Sprinklers must be special request. installed in accordance with this section. ARROW MUST POINT AWAY Nito Step A. Recessed horizontal sidewall 7/16" FROM AND BE sprinklers are to be installed in the ESCUTCHEON (11,1 mm) PERPENDICULAR O horizontal position with their center- PLATE SEATING NOMINAL TO THE BACK 44 line of waterway perpendicular to the SURFACE 1/2"** MAKE-IN WALL SURFACE back wall and parallel to the ceiling. NPT The word "TOP"on the Deflector is to 6* " face towards the ceiling. t �tiStep B.After installing the Style 10 or Ter FLOW�, �tl_5 20 Mounting Plate over the sprinkler 1 It i threads,hand tighten the sprinkler into 2-3/16") ��liam\1111 2-3/16" I 4 the sprinkler fitting. (55,6 mm 7 -wir (55,6 mm) w Step C. Tighten the sprinkler into the 1-1/2" 1 ir 2 sprinkler fitting using only the W-Type (38,1 mm) j WRENCH/'-�7 Recessed Sprinkler Wrench (Ref. I FLATS 7 01 3 Figure 6). With reference to Figure + ��� 1, the W-Type 7 Recessed Sprinkler �'-^�'-� 1 Wrench is to be applied to the sprin SHOWN SHOWN CROSS kler wrench flats. PENDENT UPRIGHT SECTION Step D. After the ceiling has been in- FIGURE2 stalled or the finish coat has been ap 5.6 K-FACTOR QUICK RESPONSE plied, slide on the Style 10 or 20 Clo SERIES TY-FRB VERTICAL SIDEWALL(TY3431)SPRINKLERS sure over the Series TY-FRB Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- if they cannot be completely cleaned The owner is responsible for the in- tact with the ceiling. by wiping the sprinkler with a cloth or spection, testing, and maintenance by brushing it with a soft bristle brush. of their fire protection system and de- Care and Care must be exercised to avoid dam- vices in compliance with this docu- age to the sprinklers before, during, ment, as well as with the applicable Maintenance and after installation. Sprinklers dam- standards of the National Fire Pro- aged by dropping, striking, wrench tection Association (e.g., NFPA 25), in The Series TY-FRB,5.6 K-factor, Hori- twist/slippage, or the like, must be addition to the standards of any oth- zontal and Vertical Sidewall Sprinklers replaced. Also, replace any sprinkler er authorities having jurisdiction. The must be maintained and serviced in that has a cracked bulb or that has installing contractor or sprinkler man accordance with this section. lost liquid from its bulb. (Ref. Installa- ufacturer should be contacted relative tion Section to any questions. Before closing a fire protection sys )• - tem main control valve for mainte- The owner must assure that the sprin- It is recommended that automatic nance work on the fire protection sys- klers are not used for hanging any ob- sprinkler systems be inspected, test- tem that it controls,permission to shut jects and that the sprinklers are only ed, and maintained by a qualified In- down the affected fire tern must be obtained protectionom thesys- cleaned by means of gently dusting eclwith ocalti requn irements and/orrvice in accordance national prop- with a feather duster; otherwise, non- er authorities and all personnel who operation in the event of a fire or inad- codes. may be affected by this action must vertent operation may result. be notified. Frequent visual inspections are rec- Absence of an escutcheon, which is ommended to be initially performed used to cover a clearance hole, may for corrosion resistant coated sprin- delay the time to sprinkler operation in klers, after the installation has been a fire situation. completed,to verify the integrity of the Sprinklers that are found to be leaking corrosion resistant coating. Thereaf- or exhibiting visible signs of corrosion ter, annual inspections per NFPA 25 must be replaced. should suffice; however, instead of in- specting from the floor level,a random Automatic sprinklers must never be sampling of close-up visual inspec- painted, plated, coated or other- tions should be made, so as to better wise altered after leaving the factory. determine the exact sprinkler condi- Modified sprinklers must be replaced. tion and the long term integrity of the Sprinklers that have been exposed to corrosion resistant coating, as it may corrosive products of combustion, but be affected by the corrosive condi- have not operated,should be replaced tions present. TFP176 Page 4 of 6 5/8±1/4" (15,9±6,4 mm) MOUNTING FACE OF WRENCH RECESS SURFACE SPRINKLER (END"A" USED FOR FITTING 1/2" NPT MODELS) A CLOSURE AIFIGURE 5 W-TYPE 6 SPRINKLER WRENCH _ 2-7/8"DIA. SERIES I'AI (73,0 mm) TY FRB �:' IIIA (57,2 mmA. WRENCH s`■ RECESS MOUNTING PLATE IF SI y . 1/8" lft (3,2 mm) 1-1/4"(31,8 mm) 3/4"(19,1 mm) PUSH WRENCH IN TO ENSURE 3/4"(19,1 mm) 1/4"(6,4 mm) ENGAGEMENT FIGURE 3 WITH SPRINKLER SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WRENCHING AREA WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT FIGURE 6 STYLE 10 RECESSED ESCUTCHEON W-TYPE 7 RECESSED SPRINKLER WRENCH 1/2±1/8" (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING A CLOSURE A 1 �= 2-7/8"IDIA. SERIES 1 W (73,0 mm) TY-FRB ■.�_'' Alli 2-1/4"(57,2 mm) A. `I i MOUNTING PLATE 1 /. y 1/8" (3,2 mm) 1-1/4"(31,8 mm) 1/2"(12,7 mm) 1"(25,4 mm) 1/4"(6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP176 Page 5 of 6 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL CHROME POLYESTER LIQUID BRASS PLATED *** LEAD COATED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 175°F(79°C) Yellow 1,2,3,4,9,10 1,2,3,9 1,2,3,9 (TY3331) 200°F(93°C) Green 286°F(141°C) Blue 5.6 RECESSED 135°F(57°C) Orange 1/2" HORIZ. 155°F(68°C) Red NPT SIDEWALL 1,2,4,9,10 1,2,9 N/A (TY3331)* 175°F(79°C) Yellow Figure 3 200°F(93°C) . Green RECESSED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 1,2,3,4,9 N/A (TY3331)** 175°F(79°C) Yellow Figure 4 200°F(93°C) Green VERTICAL 135°F(57°C) Orange SIDEWALL 155°F(68°C) Red 5.6 (TY3431) 1/2" Installed 175°F(79°C) Yellow 5,6,7,8,9 5,6,7,9 NPT Pendent or 200°F(93°C) Green Upright 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007a104)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5. Listed by Underwriters Laboratories,Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06&007a/04)as Quick Response Sprinklers. 9. Approved by the City of New York under MEA 354-01-E. 10. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resis- tant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. *Installed with Style 10(1/2"NPT)3/4"Total Adjustment Recessed Escutcheon. **Installed with Style 20(1/2"NPT)1/2"Total Adjustment Recessed Escutcheon. —Frame and deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS TFP176 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED POLYESTER LEAD COATED HORIZONTAL SIDEWALL 250 PSI(17,2 BAR) (TY3331) or 175PSI(12,1 BAR) 5.6 RECESSED HORIZ. 1/2 SIDEWALL(TY3331) (SEE NOTE 1) NPT VERTICAL SIDEWALL PSI 175 (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE P/N 57 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F(57°C) 375 VERTICAL SIDEWALL TY3431 3 PURE WHITE(RAL9010)* 155 155°F(68°C) POLYESTER 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 5 JET BLACK(RAL9005)°° 200 200°F(93°C) POLYESTER 7 LEAD COATED 286 286°F(141°C) 9 CHROME PLATED Eastern Hemisphere sales only. "Available in 155°F(68°C)or 200°F (93°C)temperature rating only. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Ordering Sprinkler Assemblies with NPT Recessed Escutcheon Thread Connections: Specify:Style(10 or 20)Recessed Es- Procedure Specify: Series TY-FRB (specify SIN), cutcheon with (specify*) finish, P/N (specify K-factor), (specify) Horizontal (specify`). Contact your local distributor for avail- Sidewall or Vertical Sidewall Sprinkler, ability. When placing an order, indi- Standard Response, Standard Cov `Refer to Technical Data Sheet TFP770 cate the full product name and Part erage, (specify) temperature rating, Sprinkler Wrench Number(P/N). (specify) finish or coating, P/N (spec- Specify: W-Type 6 Sprinkler Wrench, ify from Table C) P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright®2013 Tyco Fire Products,LP. All rights reserved. NCO TEFLON is trademark of The DuPont Corporation. Fire Protection Products tL,CD Worldwide Fire Protection Contacts www.tyco-fire.com Products Series EC-5 — 5.6 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers - General user be consulted with respect to the suitability of these corrosion resistant Description coatings for any given corrosive envi- ronment. The effects of ambient tem- ' The Series EC 5 Extended Cover- and concentration of chemicals, and gas/chemical velocity, should be age Pendent Sprinklers are decors- considered, as a minimum, along with tive glass bulb sprinklers designed -, for use in light hazard occupancies. the corrosive nature of the chemical to 3ti. They are intended for use in automatic which the sprinklers will be exposed. z sprinkler systems designed in accor- i dance with standard installation rules NOTICE (e.g., NFPA 13)for a maximum cover- The Series EC-5 Extended Coverage age area of 400 ft2 (37,2 m2), as com- Pendent Sprinklers described here- pared to the maximum coverage area in must be installed and maintained 1. of 225 ft2 (20,6 m2) for standard cov- in compliance with this document, as erage sprinklers used in light hazard "'� 9 P g well as with the applicable standards .,, occupancies. of the National Fire Protection Asso- The recessed version of the EC-5, in- ciation, in addition to the standards of tended for use in areas with a finished any other authorities having jurisdic ceiling, uses the two-piece Style 50 tion. Failure to do so may impair the , Recessed Escutcheon. The Style 50 performance of these devices. Recessed Escutcheon provides up to The owner is responsible for maintain- 3/8 inch (9,5 mm) of total adjustment ing their fire protection system and from the flush pendent position. The devices in proper operating condition. adjustment provided by the Recessed The installing contractor or sprinkler ? iii .1;41-1 Escutcheon reduces the accuracy manufacturer should be contacted to which the fixed pipe drops to the with any questions. - sprinklers must be cut. ' Corrosion resistant coatings, where Sprinkler applicable, are utilized to extend the � K .. life of copper alloy sprinklers beyondIdentification that which would otherwise be ob- tained when exposed to corrosive at- Number Discharge Coefficients mospheres. Although corrosion resis- K=5.6 GPM/psi1/2 tant coated sprinklers have passed TY3232- Pendent,5.6K (K=80,6 LPM/bar1/2) the standard corrosion tests of the ap- TY3232 is a re-designation for C3232 Temperature Ratings plicable approval agencies, the test- ing is not representative of all possible 135°F(57°C)and 155°F(68°C) corrosive atmospheres. Consequent- Technical Finish ly, it is recommended that the end Data Sprinkler: Refer to Table A Recessed Escutcheon: Brass Plated, Approvals Signal White,or Chrome Plated UL and C-UL Listed. FM and NYC Ap physical Characteristics IMPORTANT proved.(Refer to Table A for complete Frame Bronze Always refer to Technical Data approval information including corro- Button Bronze Sheet TFP700 for the "INSTALLER sion resistant status. The approvals Sealing Assembly Beryllium WARNING" that provides cau- apply to the service conditions indi- Nickel w/TEFLON tions with respect to handling cated in the Design Criteria section.) Bulb Glass(3 mm dia.) and installation of sprinkler sys- Compression Screw Bronze tems and components. lmprop- Maximum Working Pressure Deflector Brass er handling and installation can 175 psi(12,1 bar) permanently damage a sprin- Pipe Thread Connection kler system or its components 1/2 inch NPT and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 MARCH 2014 TFP228 TFP228 Page 2 of 4 Components: 1/2" ESCUTCHEON PLATE 1 Frame NPT" SEATING SURFACE 1 2- Button \ _ 3 - Sealing Assembly j f f , 4- Bulb 2 5- Compression �� } 2-1/16° Screw 3 ��i 7/16" II f (52,4 mm) 6- Deflector* J (11,1 mm) "Temperature rating is 4 I NOMINAL 1-5/16" indicated on Deflector. MAKE-IN i (33,3 mm) l N• ■ **Pipe thread 5 !c• connections per ISO 7-1 can be provided 6* on special request. FIGURE 1 SERIES EC-5 EXTENDED COVERAGE PENDENT SPRINKLER(TY3232) SPRINKLER FINISH(See Note 4) HAZARD TYPE TEMP. BULB LIQUID NATURAL CHROME POLYESTER* BRASS PLATED LIGHT 135°F(57°C) Orange 1,2,5 PENDENT Refer to Table B for UL and C-UL 155°F(68°C) Red 1,2,3,5 Sensitivity Rating and REC.PENDENT 135°F(57°C) Orange 1,2,5 Refer to Table C for FM w/Style 50 Esc. Sensitivity Rating 155°F(68°C) Red 1,2,3,5 NOTES: 1 Listed by Underwriters Laboratories,Inc.(UL). 2 Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3.Approved by Factory Mutual Research Corporation(FM). 4.Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. 5.Approved by the City of New York under MEA 113-04-E. 'Frame and Deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Operation UL and C-UL Listing Requirements FM Approval Requirements 1. The Series EC-5 Sprinklers may be The Series EC-5 Extended Coverage The glass bulb contains a fluid that ex- used for the coverage areas shown Sprinklers are to be installed in ac- pands when exposed to heat. When in Table D, based on maintaining cordance with the applicable Factory the rated temperature is reached, the the minimum specified flow rate Mutual Loss Prevention Data Sheet. fluid expands sufficiently to shatter as a function of coverage area and Information provided in the FM Loss the glass bulb, allowing the sprinkler hazard group for all of the sprin- Prevention Data Sheets relate to, but to activate and flow water. klers in the design area. are not limited to, hydraulic design, 2. With respect to heat sensitivity, the ceiling slope and obstructions, mini- Design Series EC-5 Sprinklers are permit- mum and maximum allowable spac- g ted to be used with unobstruct- ing,and deflector-to-ceiling distance. Criteria ed construction consisting of flat, smooth ceilings with a pitch of one The Series EC-5 Extended Cover- in six as defined and permitted by NFPA 13. age Pendent Sprinklers must only be installed in accordance with the ap- 3. The minimum allowableries spacing n- plicable UL and C-UL Listing or FM between the ntScold EC-5 ingSp,is Approval requirements as indicated klers,8 feet(2,4to prevent soldering, is below. Only the Style 50 Recessed The feet em). Escutcheon is to be used for recessed 4. Seriinstalledes EC 5 Sprinklers withth installation, as applicable (Ref. Table allto bet rrequirements in accordance of NFPAce A, B,and C). other of 13 for extended coverage pendent sprinklers. TFP228 Page 3 of 4 Step 3.Wrench tighten pendent sprin- AREA STYLE 135°F(57°C) 155°F(68°C) klers using only the W-Type 6 (End A) 16 x 16 Pendent QR QR Sprinkler Wrench. Wrench tighten the recessed pendent sprinklers using 16 x 16 Style 50 Recessed QR QR only the W-Type 7 Sprinkler Wrench. 18 x 18 Pendent QR QR The wrench recess of the applicable 18 x 18 Style 50 Recessed QR QR sprinkler wrench (Ref. Figure 3 and 4) is to be applied to the sprinkler wrench 20 x 20 Pendent QR N/A flats(Ref. Figure 1). 20 x 20 Style 50 Recessed QR N/A Care and QR:Quick Response N/A:Not Applicable Maintenance - TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING The Series EC-5 Extended Coverage OF SERIES EC-5 SPRINKLERS Pendent Sprinklers must be main- - tained and serviced in accordance - with this section. AREA STYLE 135°F(57°C) 155°F(68°C) Before closing a fire protection system 16 x 16 Pendent QR QR main control valve for maintenance work on the fire protection system that 16 x 16 Style 50 Recessed QR QR it controls, permission to shut down 18 x 18 Pendent QR QR the affected fire protection systems must be obtained from the proper au- 18 x 18 Style 50 Recessed QR QR thorities and all personnel who may 20 x 20 Pendent QR QR be affected by this action must be 20 x 20 Style 50 Recessed QR QR notified. QR:Quick Response Sprinklers that are found to be leaking or exhibiting visible signs of corrosion TABLE C must be replaced. SENSITIVITY RATING FOR FM APPROVAL Automatic sprinklers must never be OF SERIES EC-5 SPRINKLERS painted, plated, coated, or other- wise altered after leaving the factory. DESCRIPTION AREA GPM PSI Modified sprinklers must be replaced. Sprinklers that have been exposed to 16 x 16 26 21.6 corrosive products of combustion, but TY3232(K=5.6) have not operated,should be replaced PENDENT 18 x 18 33 34.7 if they cannot be completely cleaned 20 x 20 40 51.0 by wiping the sprinkler with a cloth or - 1 ft=0.3048 m by brushing it with a soft bristle brush. 1 ft2=0.093 m2 1 gpm=3.785 1pm Care must be exercised to avoid dam- 1 psi=0.06895 bar age to the sprinklers before, during, 1 gpm/ft2=40.74 mm/min and after installation. Sprinklers dam- aged by dropping, striking, wrench TABLED twist/slippage, or the like, must be FLOW CRITERIA FOR UL AND C-UL LISTING replaced. Also, replace any sprinkler OF SERIES EC-5 SPRINKLERS that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- Installation Do not attempt to compensate for in- tion Section). sufficient adjustment in an Escutch- Frequent visual inspections are rec- The Series EC-5 Extended Coverage eon Plate by under-or over-tightening ommended to be initially performed Pendent Sprinklers must be installed the Sprinkler. Re-adjust the position of for corrosion resistant coated sprin- in accordance with this section. the sprinkler fitting to suit. klers, after the installation has been General Instructions Step 1. The sprinkler must be in- completed,to verify the integrity of the Do not install any bulb type sprinkler stalled with the deflector parallel to corrosion resistant coating. Thereaf- if the bulb is cracked or there is a loss the mounting surface. Pendent sprin- ter, annual inspections per NFPA 25 of liquid from the bulb. With the sprin klers must be installed in the pendent should suffice; however, instead of in- kler held horizontally, a small air bub- position. specting from the floor level,a random inspec- ble should be present.The diameter of Step 2. After installing the Style 50 sampling of close-up visual the air bubble is approximately 1/16 in. mounting plate (or other escutcheon, tions should be made,sprinklerri as to better the mm). as applicable) over the sprinkler pipe determine the exactintegrityConde threads and with pipe thread seal- tion and the long term it the A leak tight 1/2 inch NPT sprinkler joint ant applied to the pipe threads, hand corrosion resistant coating as may should be obtained with a torque of 7 the sprinkler into the sprinkler tightenbe affected by the corrosive condi- to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher tittions present. levels of torque may distort the sprin The owner is responsible onsible for the in- kier inlet with consequent leakage or section, testing, and maintenance impairment of the sprinkler. of their fire protction system and de- TFP228 Page 4 of 4 2-7/8"DIA. �\ 9/16+1/8" � (73,0 mm) 7/16"(11,1 mm) —(14,2±3,2 mm) 2-1/4"DIA. 3/16"(4,8 mm) FACE OF / (57,2 mm) WRENCH RECESS SPRINKLER 3/32" (END"A" USED FITTING (2,4 mm) FOR TY3232) 1 / • FIGURE 3 � _ W-TYPE WRENCH KLER f MOUNTING MOUNTING SURFACE 114 PLATE WRENCH RECESS CLOSURE 1-1/8"(28,6 mm rl I - 7/8"(22,2 mm) si� FIGURE 2 SERIES EC-5 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/8 INCH TOTAL ADJUSTMENT 4 STYLE 50 RECESSED ESCUTCHEON 0......., vices in compliance with this docu- PUSH WRENCH ment, as well as with the applicable Ordering INTO ENSURE ENGAGEMENT standards of the National Fire Pro- tection Association (e.g., NFPA 25), in I� addition to the standards of any oth- WRENCHINGU3AREA er authorities having jurisdiction. The Contact your local distributor for avail- FIGURE 3 er ng contractor or jusrisdiction. man- ability. When placing an order, indi- W-TYPE7RECESSED inufacturer should be contacted relative cate the full product name and Part SPRINKLER WRENCH Number(P/N). to any questions. Sprinkler Assemblies with NPT It is recommended that automatic Thread Connections sprinkler systems be inspected, test- Specify:Series EC-5(TY3232), K=5.6, ed, and maintained by a qualified In- Extended Coverage Pendent Sprin- spection Service in accordance with kler, (specify) temperature rating, local requirements and/or national (specify)finish, P/N(specify): codes. 135°F(57°C) Limited Natural Brass PSN 51-051-1-135 Signal White(RAL9003) Polyester PSN 51-051-9-135 Warranty Chrome Plated PSN 51-051-9-135 For warrantyterms and conditions, 155°F(68°C) - Natural Brass PSN 51-051-1-155 visit www.tyco-fire.com. Signal White(RAL9003) Polyester PSN 51-051-4-155 Chrome Plated PSN 51-051-9-155 Recessed Escutcheon Specify: Style 50 Recessed Escutch- eon,(specify*)finish, P/N(specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify:W-Type 7 Recessed Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS(1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright®2014 Tyco Fire Products,LP. All rights reserved. two TEFLON is trademark of The DuPont Corporation. Fire Protection Products tLicciWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB - 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjust- DescrDescri tion ment or up to 1/2 in. (12,7 mm)of total iption adjustment from the flush sidewall po- TYCO Series TY-FRB 5.6 and 8.0 K- sition. The adjustment provided by factor Extended Coverage Horizon- the Recessed Escutcheon reduces s` tal Sidewall Sprinklers Quick and the accuracy to which the fixed pipe ,x Standard Response (Light Hazard) lengths to the sprinklers must be cut. are decorative 3 mm glass bulb type Corrosion resistant coatings, where spray sprinklers designed for use in applicable, are utilized to extend the hydraulically calculated sprinkler sys- life of copper alloy sprinklers beyond tems in light hazard, commercial oc- that which would otherwise be ob- cupancies such as churches, restau- tained when exposed to corrosive at- rant seating areas, hotels, educational mospheres. Although corrosion resis- facilities,offices, etc.With their cover- tant coated sprinklers have passed theAkvii age up to 16 ft. (4,9 m) wide by 24 ft. standard corrosion tests of the appli- � (7,3 m) long, they are designed for in- cable approval agencies,the testing is ` stallation along a wall or the side of a not representative of all possible cor- ) _ Oji beam and just beneath a smooth and rosive atmospheres. Consequently, it level ceiling.Horizontal sidewall(HSW) is recommended that the end user be sprinklers are commonly used instead consulted with respect to the suitabil- of pendent or upright sprinklers due ity of these coatings for any given cor- to aesthetics or building construction rosive environment.The effects of am considerations, where piping across bient temperature, concentration of the ceiling is not desirable. chemicals, and gas/chemical velocity, Sprinkler The fast response thermal sensitiv should be considered, as a minimum, ity rating of the Series TY-FRB, 3 mm along with the corrosive nature of the Identification bulb type sprinklers provides for a chemical to which the sprinklers will quick response extended coverage be exposed. Numbers (SINS) (QREC) rating for many of the cover- NOTICE cover- age areas detailed in Tables B and C. TY3332-EC HSW,5.6K,1/2"NPT The recessed version of the Series The Series TY-FRB Sprinklers de- TY4332-EC HSW,8.0K,3/4"NPT TY-FRB Extended Coverage Horizon scribed herein must be installed and tal Sidewall Sprinkler utilizes either maintained in compliance with this a two-piece Style 10 (1/2 inch NPT) document, as well as with the appli- or Style 40 (3/4 inch NPT) Recessed cable standards of the National Fire Escutcheon with 1/2 in. (12,7 mm) of Protection Association (NFPA), in ad- recessed adjustment or up to 3/4 in. dition to the standards of any other (19,1 mm)of total adjustment from the authorities having jurisdiction. Failure flush sidewall position, or a two-piece to do so may impair the performance Style 20 (1/2 in. NPT) or Style 30 (3/4 of these devices. The owner is responsible for main- taining their fire protection system IMPORTANT and devices in proper operating con- Always refer to Technical Data dition. Contact the installing contrac- Sheet TFP700 for the "INSTALLER tor or product manufacturer with any WARNING" that provides cau- questions. tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 SEPTEMBER 2014 TFP296 TFP296 Page 2 of 8 Componen1 Frame is DEFLECTOR 4 ■echnical 2 - Button HAT �\ I rA►,grjgrpr, Data 3 - Sealing Assembly 4 - Bulb �pr, Approvals 5 - Compression Screw %; 'A,ly► UL and C-UL Listed 6 - Deflector* FM and NYC Approved 7 - Ejection Spring 6* 5 2 3 1 (Refer to Table A for complete approv- al information including corrosion re- *Temperature rating is indicated sistant status, as well as the Design on Deflector or adjacent to orifice WRENCH g seat on Frame. 7 FLATS Criteria section pertaining to special 1/2"** design considerations.) . + NPT Maximum Working Pressure °ierit,0 7/16" (11,1 mm) I Refer to Table B. s�I Y �1 ,44 — Di 5 6 gpm/ps e Coefficient 1.01 ,44 Ipm/bar1i2) ��'� / Itkl"1/"W K=8.0 gpm/psi112(115,2 Ipm/bar112) 1-9/16" CENTERLINE Temperature Ratings ~(3 OF SPRINKLER 7/16" Refer to Table A. WATERWAY (11,1 mm) NOMINAL Finishes MAKE-IN Sprinkler: Refer to Table E. **Pipe thread connections per 1.1/2„ Recessed Escutcheon: White Coated, ISO 7-1 can be provided on —(38,1 mm)----- Chrome Plated,or Brass Plated special request. Physical Characteristics 7/16" 2-3/16" Frame Bronze (11,1 mm)~ (55,6 mm)—~ Button Brass/Copper FIGURE 1 Button Brass/Copper SERIES TY-FRB(TY3332) Sealing Assembly Beryllium Nickel EXTENDED COVERAGE w/TEFLON HORIZONTAL SIDEWALL SPRINKLER Bulb Glass 5.6 K-FACTOR, 1/2 INCH NPT Compression Screw Bronze Deflector Copper Components Operation DEFLECTOR 1 - FrameuHAT 4 '��Y��i1 The glass bulb contains a fluid which R. expands when exposed to heat.When 3 - Sealing Assembly �� o. the rated temperature is reached, the 4 Bulb \��� fluid expands sufficiently to shatter 5 - Compression Screw ,;,\,, the glass bulb, allowing the sprinkler 6 Deflector* / 1 to activate and water to flow. 7 - Ejection Spring ' _ 6* 5 2 3 1 Design *Temperature rating is indicated on Deflector or adjacent to orifice WRENCH seat on Frame. 7 FLATS 3/4"** Criteria / /NPT TYCO Series TY-FRB 5.6 and 8.0 K- ___ - 1 ■ -� factor Extended Coverage Horizon- tal�= 7/16"(11,1 mm) I ' II�III� tal Sidewall Sprinklers Quick and ® 0,�� — Standard Response (Light Hazard) I'1, / must be installed and utilized in Light `. 1�� Hazard Occupancies, under smooth 1.1/2„ CENTERLINE level ceilings as outlined in the appli- ~(38,1 mm)y1/2"SPRINKLER 1/2" able installation standard recognized WATERWAY (12,7 mm) by the Approval Agencyrec- NOMINAL 9 Y(e.g.,Mro nize ognizes NFPA 13, and FM recognize MAKE-IN the FM Loss Prevention Data Sheets). **Pipe thread connections per 1-1/2" Only the Style 10, 20, 30, or 40 Re- ISO 7-1 can be provided onx(38,1 mm)~ cessed Escutcheon, as applicable, is special request. to be used for recessed installations. 9/16" 2-1/4" (14,3 mm)~ (57,2 mm)_ FIGURE 2 SERIES TY-FRB(TY4332) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER 8.0 K-FACTOR,3/4 INCH NPT TFP296 Page 3 of 8 SPRINKLER FINISH(S) K-FACTOR SPRINKLER TEMPERATURE BULB TYPE RATING LIQUID COLOR NATURAL CHROME POLYESTER*** BRASS PLATED 5.6 135°F(57°C) Orange 1/2" EC HSW 155°F(68°C) Red 1,2,3,4 NPT (TY3332) 175°F(79°C) Yellow 135°F(57°C) Orange 5.6 RECESSED EC HSW* 1/2" (TY3332) 155°F(68°C) Red 1,2,4 NPT 175°F(79°C) Yellow 135°F(57°C) Orange 1/2 RECESSED EC HSW** 155°F(68°C) Red 1,2,3,4 NPT (TY3332) 175°F(79°C) Yellow 8.0 , 135°F(57°C) Orange 3/4" EC HSW 155°F(68°C) Red 1,2,3,4 NPT (TY4332) 175°F(79°C) Yellow 135°F(57°C) Orange 8.0 RECESSED EC HSW* 1,2,4 3/4" (TY4332) 155°F(68°C) Red NPT 175°F(79°C) Yellow 1,2,3,4 135°F(57°C) Orange 8.0 RECESSED EC HSW** 3/4" (TY4332) 155°F(68°C) Red 1,2,3,4 NPT 175°F(79°C) Yellow Notes: 1. Listed by Underwriters Laboratories,Inc.(UL)per Table C 2. Listed by Underwriters Laboratories,Inc.for use in Canada per Table C 3. Approved by Factory Mutual Research Corporation(FM)per Table D 4. Approved by the City of New York under MEA 354-01-E 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed corrosion-resistant sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable ** Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable ***Frame and deflector only TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) SPRINKLER FINISH K-FACTOR SPRINKLER TYPE NATURAL CHROME POLYESTER BRASS PLATED EC HSW 5.6 (TY3332) 1/2" 250 PSI(17,2 BAR) NPT RECESSED EC HSW (TY3332) OR EC HSW 175 PSI(12,1 BAR) 8.0 3/4" (TY4332) (SEE NOTE 1) NPT RECESSED EC HSW (TY4332) Notes: 1.The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE TFP296 Page 4 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY3332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Area(1), Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), g Ft x Ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F Ft(m) Quick 16 x 16(4,9 x 4,9) 26(98) 21.6(1,48) 4 to 12(100 to 300) 135,155, 175 10(3,1) Quick 16 x 18(4,9 x 5,5) 29(110) 26.8(1,85) 4 to 12(100 to 300) 135,155,175 10(3,1) Quick 16 x 20(4.9 x 6,1) 32(121) 32.7(2,25) 4 to 6(100 to 150) 135 10(3,1) Quick 16 x 22(4,9 x 6,7) 35(133) 39.1 (2,70) 4 to 6(100 to 150) 135 10(3,1) Standard 16 x 20(4,9 x 6,1) 32(121) 32.7(2,25) 4 to 6(100 to 150) 155 10(3,1) Standard 16 x 22(4,9 x 6,7) 35(133) 39.1 (2,70) 4 to 6(100 to 150) 155,175 10(3,1) 8.0K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY4332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Area(11, Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), Ft x Ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F Ft(m) Quick 16 x 16(4,9 x 4,9) 26(98) 10.6(0,73) 4 to 12(100 to 300) 135,155,175 10(3,1)/13(4,0)(5) Quick 16 x 18(4,9 x 5,5) 29(110) 13.1 (0,90) 4 to 12(100 to 300) 135,155,175 10(3,1)/13(4,0)15) Quick 16 x 20(4.9 x 6,1) 32(121) 16.0(1,10) 4 to 6(100 to 150) 135 10(3,1)/13(4,0)(5) Quick 16 x 20(4.9 x 6,1) 33(125) 17.0(1,17) 4 to 12(100 to 300) 135 10(3,1)/13(4,0)(5) Quick 16 x 22(4,9 x 6,7) 35(133) 19.1 (1,32) 4 to 6(100 to 150) 135 10(3,1)/13(4,0)15) Quick 16 x 22(4,9 x 6,7) 36(136) 20.3(1,59) 4 to 12(100 to 300) 135 10(3,1)/13(4,0)(5) Quick 16 x 24(4,9 x 7,3) 39(148) 23.8(1,64) 4 to 6(100 to 150) 135 10(3,1)/13(4,0)15) Quick 16 x 24(4,9 x 7,3) 40(151) 25.0(1,72) 4 to 12(100 to 300) 135 10(3,1)/13(4,0)(5) Standard 16 x 20(4.9 x 6,1) 32(121) 16.0(1,10) 4 to 6(100 to 150) 155 10(3,1)/13(4,0)15) Standard 16 x 20(4.9 x 6,1) 33(125) 17.0(1,17) 4 to 12(100 to 300) 155 10(3,1)/13(4,0)15) Standard 16 x 22(4,9 x 6,7) 35(133) 19.1 (1,32) 4 to 6(100 to 150) 155,175 10(3,1)/13(4,0)(5) Standard 16 x 22(4,9 x 6,7) 36(136) 20.3(1,59) 4 to 12(100 to 300) 155,175 10(3,1)/13(4,0)15) Standard 16 x 24(4,9 x 7,3) 39(148) 23.8(1,64) 4 to 6(100 to 150) 155,175 10(3,1)/13(4,0)(5) Standard 16 x 24(4,9 x 7,3) 40(151) 25.0(1,72) 4 to 12(100 to 300) 155,175 10(3,1)/13(4,0)(5) Notes: 1.Backwall(where sprinkler is located)by sidewall(length of throw) 2.Requirement is based on minimum flow in gpm from each sprinkler.The indicted residual pressures are based on the nominal K-factor. 3.The centerline of the sprinkler waterway is located 7/16 in.(11,1 mm)below the deflector(Ref.Figures 1 and 2). 4.Minimum spacing is for lateral distance between sprinklers located along a single wall,otherwise adjacent sprinklers(i.e.,sidewall sprinklers on an adjacent wall,on an opposite wall,or pendent sprinklers)must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. 5.Minimum spacing is 13 ft.(4,0 m)when design pressure exceeds 175 psi(12,1 bar),otherwise the minimum spacing is 10 ft.(3 m). TABLE C UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA TFP296 Page 5 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY3332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Areal f, Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), Ft x Ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F Ft(m) Quick 16 x 16(4,9 x 4,9) 26(98) 22(1,51) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 18(4,9 x 5,5) 30(114) 29(2,00) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 20(4.9 x 6,1) 33(125) 35(2,41) 4 to 12(100 to 300) 135,155 10(3,1) Standard 16 x 16(4,9 x 4,9) 26(98) 22(1,51) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 20(4,9 x 6,1) 30(114) 29(2,00) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 22(4,9 x 6,7) 33(125) 35(2,41) 4 to 12(100 to 300)) 175 10(3,1) 8.0K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY4332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Areal), Flow(2), Pressurel2), Distance(3), Temperature Spacing(4), Ft x Ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F Ft(m) Quick 16 x 16(4,9 x 4,9) 32(121) 16(1,10) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 18(4,9 x 5,5) 36(136) 20(1,38) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 20(4.9 x 6,1) 40(151) 25(1,72) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 22(4,9 x 6,7) 44(167) 30(2,06) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 24(4,9 x 6,7) 48(182) 36(2,48) 4 to 12(100 to 300) 135,155 10(3,1) Standard 16 x 16(4,9 x 4,9) 32(121) 16(1,10) 4 to 12(100 to 300)) 175 10(3,1) Standard 16 x 18(4,9 x 5,5) 36(136) 20(1,38) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 20(4.9 x 6,1) 40(151) 25(1,72) 4 to 12(100 to 300)) 175 10(3,1) Standard 16 x 22(4,9 x 6,7) 44(167) 30(2,06) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 24(4,9 x 6,7) 48(182) 36(2,48) 4 to 12(100 to 300) 175 10(3,1) Notes: • 1.Backwall(where sprinkler is located)by sidewall(length of throw) 2.Requirement is based on maintaining both minimum flow and minimum residual pressure. 3.The centerline of the sprinkler waterway is located 7/16 inch(11,1 mm)below the deflector(Ref.Figures 1 and 2). 4.Minimum spacing is for lateral distance between sprinklers located along a single wall,otherwise adjacent sprinklers(i.e.,sidewall sprinklers on an adjacent wall,on an opposite wall,or pendent sprinklers)must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. TABLE D FM COVERAGE AND FLOW RATE CRITERIA TFP296 Page 6 of 8 Series TY-FRB EC the affected fire protection system Sidewall Sprinkler must be obtained from the proper au- The Series TY-FRB EC Sidewall Sprin- thorities and all personnel who may WRENCH RECESS klers must be installed in accordance be affected by this action must be (END"A" USED FOR with the following instructions: notified. 1/2" NPT MODELS) Step 1. Horizontal sidewall sprinklers The owner must assure that the sprin- \ are to be installed with their center- klers are not used for hanging of any line perpendicular to the back wall and objects; otherwise, non-operation in NCparallel to the ceiling.The word "TOP" the event of a fire or inadvertent op- (END NC H RECESS USED FOR on the deflector is to face towards the eration may result. 3/4" NPT MODELS) ceiling. Absence of an escutcheon, which is FIGURE 3 Step 2. With pipe thread sealant ap- used to cover a clearance hole, may - W-TYPE 6 plied to the pipe threads, hand tighten delay the time to sprinkler operation in SPRINKLER WRENCH the sprinkler into the sprinkler fitting. a fire situation. Step 3. Tighten the sprinkler into the Sprinklers that are found to be leaking sprinkler fitting using only the W-Type or exhibiting visible signs of corrosion - WRENCH 6 Sprinkler Wrench (Ref. Figure 3). must be replaced. RECESS With reference to Figures 1 and 2, the e W-Type 6 Sprinkler Wrench is to be Automatic sprinklerse , coated must never r- � applied to the sprinkler wrench flats. painted, plated, or other wise altered after leaving the factory. MI Series TY-FRB Recessed EC Modified sprinklers must be replaced. Sidewall Sprinkler Sprinklers that have been exposed to The Series TY-FRB Recessed EC corrosive products of combustion, but .14 Sidewall Sprinklers must be installed have not operated,should be replaced in accordance with the following if they cannot be completely cleaned instructions: by wiping the sprinkler with a cloth or PUSH WRENCH by brushing it with a soft bristle brush. INTO ENSURE Step 1. Horizontal sidewall sprinklers ENGAGEMENT are to be installed with their center- Care must be exercised to avoid WITH SPRINKLER line perpendicular to the back wall and damage to the sprinklers before, WRENCHING AREA parallel to the ceiling.The word "TOP" during, and after installation. Sprin- FIGURE 4 on the deflector is to face towards the klers damaged by dropping, strik- W-TYPE 7 RECESSED ceiling. ing, wrench twist/slippage,or the like, SPRINKLER WRENCH Step 2. After installing the Style 10, must be replaced. Also, replace any 20,30,or 40 Mounting Plate, as appli- that h sr thatliquid has a cracked bulb or t cable, over the sprinkler threads and that has lost from its bulb.(Refer Installation with pipe thread sealant applied to the to Installation Section.) TYCO Series TY-FRB 5.6 and 8.0 K- pipe threads, hand tighten the sprin- Frequent visual inspections are rec- factor Extended Coverage Horizontal kler into the sprinkler fitting. ommended to be initially performed sprin- Sidewall Sprinklers Quick and Stan- Step 3. Tighten the sprinkler into the for corrosion resistant coated dard Response (Light Hazard) must sprinkler fittingusingonlythe W-Type klers,omafter the installationifyt integrity has ofthe P ( g P yP completed,to verify the the be installed in accordance with this 7 Recessed Sprinkler Wrench (Ref. corrosion resistant coating. Thereaf- - section. Figure 4). With reference to Figure 1 ter, annual inspections per NFPA 25 Do not install any bulb type sprinkler if or 2,the W Type 7 Recessed Sprinkler should suffice; however, instead of in- the bulb is cracked or there is a loss of Wrench is to be applied to the sprin specting from the floor level,a random liquid from the bulb.With the sprinkler kler wrench flats. sampling of close-up visual inspec- held horizontally, a small air bubble Step 4. After the wall has been in- tions should be made, so as to better should be present. The diameter of stalled or the finish coat has been ap- determine the exact sprinkler condi- the air bubble is approximately 1/16 plied, slide on the Style 10, 20, 30, or tion and the long term integrity of the inch(1,6 mm). 40 Closure over the Series TY-FRB corrosion resistant coating, as it may A leak tight 1/2 inch NPT sprinkler Sprinkler and push the Closure over be affected by the corrosive condi- joint should be obtained with a torque the Mounting Plate until its flange tions present. of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A comes in contact with the wall. The owner is responsible for the in- leak tight 3/4 inch NPT sprinkler joint spection, testing, and maintenance of Care and should be obtained with a torque of 10 their fire protection system and devic- to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher es in compliance with this document, levels of torque may distort the sprin- Maintenance as well as with the applicable stan- kler inlet and cause leakage or impair- dards of the National Fire Protection ment of the sprinkler. TYCO Series TY-FRB 5.6 and 8.0 K- Association (e.g., NFPA 25), in addi- factor Extended Coverage Horizontal tion to the standards of any other au- Dont attempt em t tont in make-upefor orcheon Sidewall Sprinklers Quick and Stan- thorities having jurisdiction. Contact dard Response (Light Hazard) must the installing contractor or product plate by under- or over-tightening the be maintained and serviced in accor- manufacturer with any questions. sprinkler. Readjust the position of the dance with this section. sprinkler fitting to suit. It is recommended that automat- Before closing a fire protection system is sprinkler systems be inspected, main control valve for maintenance tested, and maintained by a qualified work on the fire protection system that Inspection Service in accordance with it controls, permission to shut down local requirements and/or national codes. TFP296 Page 7 of 8 y 5/8±1/4" 1/2±1/8" (15,916,4 mm) (12,7±3,2 mm) FACE OF FACE OF MOUNTING MOUNTING SURFACE --- SPRINKLER SURFACE ' -- -- SPRINKLER FITTING FITTING al KM CLOSURE 1 I CLOSURE 1 I 2-7/8"DIA. 2-7/8"DIA. (73,0 mm) (7 SERIES SERIES (73,0 mm) TY-FRB EC �;i,nlllll 2-1/4"DIA. TY FRB EC ����,n 2-1/4"DIA. =III: (57,2 mm) WEN (57,2 mm) lEi MOUNTING 'II �p MOUNTING Ii 1 �I➢ PLATE NA \) I`4i 1/8" I I 1/8 ---•-- (3,2 mm) (3,12/8m" 1-1/4"(31,8 mm) 3/4" (19,1 mm) 1-1/4"(31,8 mm) 1/2"(12,7 mm) 3/4"(19,1 mm) y 1/4"(6,4 mm) 1"(25,4 mm) 1/4"(6,4 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED EC SIDEWALL SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACOTR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT 5/8±1/4" 1/2±1/8" y (15,9±6,4 mm) (12,7±3,2 mm) MOUNTING FACE OF MOUNTING FACE OF SURFACE --- SPRINKLER SPRINKLER FITTING SURFACE -� FITTING al 011 • CLOSURE I CLOSURE 1 2-7/8"DIA. 2-7/8"DIA. - SERIES�A (73,0 mm) SERIES (73,0 mm) TY-FRB EC ��'I I 2-1/4"DIA. TY-FRB EC (���p, I 2-1/4"DIA. \�_-I. (57,2 mm) \ =�I (57,2 mm) �. j I Il MOUNTING I, - MOUNTING I' np PLATE 1PLATE �I`��� t 1))�H y l III 1/8" y if 1/8" (3,2 mm) (3,2 mm) 1-1/4"(31,8 mm) 3/4"(19,1 mm) 1-1/4"(31,8 mm) _ 1/2"(12,7 mm) 3/4"(19,1 mm) ~_ 1/4"(6,4 mm) 1"(25,4 mm) 1/4"(6,4 mm) FIGURE 7 FIGURE 8 SERIES TY-FRB RECESSED EC SIDEWALL SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 8.0 K FACTOR,3/4 INCH NPT TFP296 Page 8 of 8 57 - XXX - X - XXX SPRINKLER FINISH 1 NATURAL BRASS TEMPERATURE SIN 3 PURE WHITE(RAL9010) RATING POLYESTER 135 135°F(57°C) 376 5.6K EC HSW TY3332 4 SIGNAL WHITE(RAL9003) 155 155°F(68°C) 396 8.0K EC HSW TY4332 POLYESTER 175 175°F(79°C) 5 JET BLACK(RAL9005) POLYESTER 9 CHROME PLATED TABLE E SERIES TY-FRB EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS PART NUMBER SELECTION Limited Warranty For warrany terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number(P/N). Sprinkler Assembly with NPT Thread Connections Specify: Series TY-FRB, (specify SIN), Extended Coverage Horizontal Side- wall Sprinkler, K=(specify), (specify) temperature rating, (specify) finish, P/N(specify from Table E) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify') finish, P/N(specify") *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t`f co TEFLON is trademark of the DuPont Corporation Fire Protection Products Vico Worldwide www.tyco-fire.com Fire Protection Contacts Products Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage - General The owner is responsible for maintain- ing their fire protection system and Description devices in proper operating condi- tion. Contact the installing contrac- 3 TYCO Series DS-1 Dry Type Sprinklers, tor or product manufacturer with any 5.6K Pendent, Upright, and Horizontal questions. Sidewall,Quick Response(3 mm bulb) The Series DS-1 Dry-Type Sprinklers y and Standard Coverage are decora- must only be installed in fittings that tive glass bulb automatic sprinklers meet the requirements of the Design designed for commercial use.Dry-type Criteria section. ,Pt .' sprinklers are typically used where: • pendent sprinklers are required on Sprinkler r dry pipe systems that are exposed to freezing temperatures (e.g., Identification s sprinkler drops from unheated portions of buildings) Numbers (SINS) r,. ,,, • sprinklers and/or aportion of the 3/4 Inch NPT: connecting piping are exposed to TY3935 -Pendent freezing temperatures;for example, TY3735 -Horizontal Sidewall sprinkler drops from wet systems 1 Inch NPT: into freezers, sprinkler sprigs TY3235 -Pendent from wet systems into unheated TY3135 -Upright attics, or horizontal piping exten- -Horizontal Sidewall sions through a wall to protect an Technical unheated areas such as loading docks, overhangs, and building Data ,.�, exteriors • sprinklers are used on systems that Upand C UL Listed are seasonally drained to avoid FM Approved freezing (e.g.,vacation areas) NYC Approved under MEA 352-01-E NOTICE Previous New York City Approval and Finishes The Series DS-1 Dry Type Sprinklers MEA certification numbers apply to Sprinkler:Natural Brass,Chrome Plated, described herein must a installed product as shown in this data sheet. or Signal White In accordance with Section BC 3502 and maintained in compliance with this of the Construction Code,current NYC Escutcheon:Signal White,Chrome Plated, document,as well as with the applica- Approvals for use in the City of New or Brass Plated ble standards of the National Fire Pro- York apply to all products that contain Physical Characteristics tection Association(NFPA),in addition UL or FM Approvals and Listings; Inlet Copper to the standards of any authorities therefore, not all products currently Plug Copper having jurisdiction. Failure to do so Yoke Stainless Steel may impair the performance of these Approved for use in the City of New Casing Galvanized Carbon Steel York will carry an actual MEA Certifi- Insert Bronze devices. cation number. Bulb Seat Stainless Steel Refer to Tables A and B. Bulb Glass IMPORTANT y Maximum WorkingPressure CompressionoScrew Bronze Always refer to Technical Data Deflector Bronze Sheet TFP700 for the "INSTALLER 175 psi(12,1 bar) Frame Bronze WARNING" that provides cautions Inlet Thread Connections Guide Tube Stainless Steel water rube Stainless Steel with respect to handling and instal- 3/4 Inch NPT Spring Stainless Steel lation of sprinkler systems and com- 1 Inch NPT or ISO 7-R 1 Plug Spring* Stainless Steel ponents. Improper handling and Sealing Assembly. Beryllium Nickel w/TEFLON installation can permanently damage Discharge Coefficient Escutcheon Carbon Steel a sprinkler system or its compo- K=5.6 gpm/psi1/2(80,6 Ipm/barl/2) *For 3/4 inch NPT only nents and cause the sprinkler to fail Temperature Ratings to operate in a fire situation or cause Refer to Tables A and B it to operate prematurely. Page 1 of 10 June 2015 TFP510 TFP510 Page 2 of 10 PLUG WITH riW,ti INLET Operation SEALING iASSEMBLY When the TYCO Series DS-1 Dry-Type ill YOKE Sprinklers,5.6K Pendent,Upright,and � ISI i Horizontal Sidewall, Quick Response -I-II 4 (3 mm bulb) and Standard Coverage PLUG i;=(1 INLET are in service, water is prevented from SPRING t BAND A entering the assembly by the Plug with ii II ; Sealing Assembly in the Inlet of the WATER SPRING Sprinkler.See Figures 1 and 2. TUBE S I, 1 The glass bulb contains a fluid that 1, 1 CASING expands when exposed to heat.When �, the rated temperature is reached, the 1'M fluid expands sufficientlyto shatter GUIDE 11$,_7i.�� INSERT P TUBE the glass Bulb, and the Bulb Seat is t 1 released. Nlibl BULB Epi ` 0 SEAT The compressed Spring is then able FRAME , I� O> to expand and push the Water Tube as JI(' well as the Guide Tube outward. This � 3 mm BULB action simultaneously pulls inward on VENT HOLE III 1011 the Yoke, withdrawing the Plug with �` Sealing Assembly from the Inlet and DEFLECTOR .� COMPRESSION allowing the sprinkler to activate and SCREW flow water. FIGURE 1 Design SERIES DS-1,3/4 INCH NPT,DRY-TYPE SPRINKLER ASSEMBLY Criteria �,•, The TYCO Series DS-1 Dry-Type Sprin- PLUG WITH ,a INLET klers,5.6K Pendent,Upright,and Hor- SEALING 1II izontal Sidewall, Quick Response ASSEMBLY ' F (3 mm bulb) and Standard Cover- f16 YOKE age are intended for use in fire sprin- kler systems designed in accordance SPRING with the standard installation rules k s(I INLET recognized by the applicable Listing T___' k BAND � or Approval agency; for example, WATER i UL Listing is based on NFPA 13 TUBE requirements. ` 1 CASING �;, 1 Sprinkler Fittings Install the 3/4 or 1 inch NPT Series GUIDE 1 I� ► INSERT DS-1 Dry-Type Sprinklers in the 3/4 or TUBE i Ib��1 1 inch NPT outlet or run of the follow- ii6k ing fittings: 0 1 BULB • malleable or ductile iron threaded FRAME ,SIM �i SEAT • tee fittings that meet the dimen- �iRAM' sional requirements of ANSI B16.3 �, (Class 150) VENT HOLE I �I� `01il 3 mm BULB Sir l. • cast iron threaded tee fittings that meet the dimensional requirements COMPRESSION of ANSI B16.4(Class 125) DEFLECTOR SCREW Do not install the DS-1 Sprinklers FIGURE 2 into an elbow fittings. The Inlet of the SERIES DS-1, 1 INCH NPT AND ISO 7-R 1 DRY-TYPE SPRINKLER sprinkler can contact the interior of the ASSEMBLY elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP510 Page 3 of 10 3/4 Inch NPT TY3935 Pendent TY3935 Pendent TY3735 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) without Escutcheon (Figure 10) Temperature Bulb Finish Rating Color Code Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow 1,2 1,2 1*,2* 200°F(93°C) Green 286°F(141°C) Blue Notes: 1. Listed by Underwriters Laboratories,Inc.(maximum order length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada(maximum order length of 48 inches) Light and Ordinary Hazard occupancies only TABLE A 3/4 INCH NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1 Inch NPT(and ISO 7-R 1) TY3235 Pendent TY3235 Pendent TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) TY3135 Upright without Escutcheon without Escutcneont (Figure 10) (Figure 7) Temperature Bulb Finish Rating Color Code Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F(57°C) Orange 155°F(68°C) Red 1,2,3,4 1,2,4 175°F(79°C) Yellow 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 200°F(93°C) Green 286°F(141°C) Blue 1,2,4 Notes: 1. Listed by Underwriters Laboratories,Inc.(maximum order length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada(maximum order length of 48 inches) 3. Approved by Factory Mutual Research Corporation(maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352-01-E 5. The Upright Sprinkler without an Escutcheon(TY3135)is available in 1 inch NPT only Light and Ordinary Hazard occupancies only " Light Hazard occupancies only TABLE B 1 INCH NPT(AND ISO 7-R 1)SERIES DS-1 QUICK RESPONSE,STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP51O Page 4 of 10 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN CRITERIA SECTION) CRITERIA SECTION) CRITERIA SECTION) FACE OF FACE OF FACE OF SPRINKLER SPRINKLER SPRINKLER FITTING ( 1 „ FITTING FITTING L_ - _J \ L _J \ L_ __ ORDER LENGTHS: ORDER LENGTHS: ORDER LENGTHS: 3-1/2"DIA. 2-3/4"to 48" 1-3/4"DIA. 3-3/4"to 48" 1/2"to 46" —(88,9 mm)— (69,9 to 1219,2 mm) (44,5 mm) (95,3 to 1219,2 mm) (12,7 to 1168,4 mm) IN 1/4"(6,4 mm) _ IN 1/4"(6,4 mm) 2-1/4"DIA. IN 1/4"(6,4 mm) 2�1/2"DIA. INCREMENTS INCREMENTS (57,2 mm) INCREMENTS (63,5 mm) 1 f/1 ___/ I FACE OF 1 . •%- FACI E OF • CEILING FACE OFIE V CEILING %/���■� CEILING I III (108,0±3,2 mm) r 2-3/16I"±1/8" 3"DIA. 1-3/8"±1/8" 2-7/8"DIA. 1' (55,6±3,2 mm) (76,2 mm) (34,9±3,2 mm) (73,0 mm) km t/ ■ FIGURE 3 FIGURE 4 FIGURE 5 PENDENT TY3235 AND TY3935 PENDENT TY3235 AND TY3935 PENDENT TY3235 AND TY3935 WITH STANDARD WITH RECESSED WITH DEEP ESCUTCHEON ESCUTCHEON ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN TOP OF CRITERIA SECTION) DEFLECTOR FACE OF SPRINKLER FITTING L -J ORDER LENGTHS: I5"to 48" (127,0 to 1219,2 mm) ORDER LENGTHS: IN 1/4"(6,4 mm) 5"to 48" INCREMENTS (127,0 to 1219,2 mm) IN 1/4"(6,4 mm) INCREMENTS _ FACE OF 4 SPRINKLER FITTING MINIMUM l r 1-3/4"(44,5 mm) fi_ DEFLECTOR TO CEILING SPRINKLER FITTING (REFER TO DESIGN } CRITERIA SECTION) FIGURE 6 FIGURE 7 PENDENT TY3235 AND TY3935 UPRIGHT TY3135 WITHOUT WITHOUT ESCUTCHEON ESCUTCHEON 1 INCH NPT ONLY TFP510 Page 5 of 10 ORDER LENGTHS: The configuration shown in Figure 12 2-3/4"to 48"(69,9 to 1219,2 mm) is only applicable for wet pipe systems IN 1/4"(6,4 mm)INCREMENTS where the sprinkler fitting and water I _ 2-3/8"±1/8" filled pipe above the sprinkler fitting are ~' (60,3±3,2 mm) not subject to freezing and where the FACE OF FACE OF length of the Dry-Type Sprinkler has the — SPRINKLER MOUNTING— minimum exposure length depicted in FITTING SURFACE Figure 11.Refer to the Exposure Length \ }I section. II ' -1"- 1 i 3"DIA. For wet pipe system installations of Eli 1161111� J , (76,2 mm) the 1 inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, -7 3.5° I use only the following TYCO CPVC • SPRINKLER FITTING 1-3/4"DIA. fittings: (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16" • 1" x 1" NPT Female Adapter (P/N CRITERIA SECTION) OF WATERWAY (7,9 mm) 80145) FIGURE 8 • 1" x 1" x 1" NPT Sprinkler Head TY3335 AND TY3735 HORIZONAL SIDEWALL Adapter Tee(P/N 80249) WITH STANDARD ESCUTCHEON For wetY Pip i e system installations of the the 3/4 inch NPT Series DS-1 Sprin- ORDER LENGTHS: klers connected to CPVC piping, use 1/2"to 45-3/4"(12,7 to 1162,1 mm) in the 3/4"x 3/4" NPT Female Adapter IN 1/4"(6,4 mm)INCREMENTS (P/N 80142). Ik _ 4-1/4"±1/8" 2-1/2"DIA. FACE OF (108,0±3,2 mm) For dry pipe system installations, use OF MOUNTING only the side outlet of maximum 2-1/2- FACE (63,5 mm) inch reducingtee when locatingthe _ SPRINKLER TTSURFACE Series DS-1 prinklers directly elow the branch line. Otherwise, use the III` `{� I. _ + i configuration shown in Figure 13 to 'IIIIIIillllllll� 3-1/2"DIA. assure complete water drainage from I` j� (88,9 mm) above the Series DS-1 Dry-Type Sprin- -_Li ` 3.5° klers and the branch line. Failure to do l so may result in pipe freezing and water SPRINKLER FITTING damage. (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) NOTICE FIGURE 9 Do not install the Series DS-1 Dry-Type TY3335 AND TY3735 HORIZONAL SIDEWALL Sprinkler into any other type fitting WITH DEEP ESCUTCHEON without first consulting the Technical Services Department.Failure to use the ORDER LENGTHS: appropriate fitting may result in one of 5-1/2"to 48"(139,7 to 1219,2 mm) the following: IN 1/4"(6,4 mm)INCREMENTS MINIMUM • failure of the sprinkler to operate 2-1/4"(57,2 mm) properly due to formation of ice FACE OF --DEFLECTOR TO over the inlet Plug or binding of the SPRINKLER MOUNTING Inlet Plug FITTING SURFACE • insufficient engagement of the Inlet pipe threads with consequent ,-„-1,, + leakage Drainage / In accordance with the minimum -� 3.5° 5/16" requirements of the National Fire Pro- SPRINKLER FITTING (7,9 mm) tection Association for dry pipe sprin- (REFER TO CENTERLINE kler systems, branch, cross, and (REFER DESIGNION) OF WATERWAY feed-main piping connected to Dry Sprinklers and subject to freezing tern- FIGURE 10 peratures must be pitched for proper TY3335 AND TY3735 HORIZONAL SIDEWALL drainage. WITHOUT ESCUTCHEON Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use TFP510 Page 6 of 10 ---- RUN FACE OF TO WET SIDE fi r P OUTLET SPRINKLER SYSTEM OUTLET PLUGGED FITTING PLUGGED , f�SPRINKLER HEATED EXPOSURE HEATED TO DRY FITTING AREA SYSTEM (SEE DESIGN AREA LENGTH CRITERIA (SEE DESIGN SECTION) DSB-2 CRITERIA DSB-2 SPRINKLER AREA INTENDED SECTION) INTENDED FITTING SUBJECT DSB-2 FOR FREEZER FOR FREEZER (SEE DESIGN TO INTENDED STRUCTURES STRUCTURES CRITERIA FREEZING FOR FREEZER SECTION) STRUCTURES 1*1110, n:72: y3 7:: 73 .....0 ......c FIGURE 11 FIGURE 12 FIGURE 13 EXPOSURE SPRINKLER FITTING SPRINKLER FITTING LENGTH HEATED AREA UNHEATED AREA STRAP TIES 1-3/4"DIA. _ (ENDS ON (44,5 mm) OPPOSING CLEARANCE INSULATED SIDES OF HOLE FREEZER WRENCH BOOT) ADHESIVE STRUCTURE RECESS DSB-2 BOOT DSB-2 / IADHESIVE BOOT ✓�% 1-3/4"DIA. �_ WRENCH (44,5 mm) 11 FLAT (4).CLEARANCE ,III' )i INSULATED FREEZER Vim` I PUSH WRENCH J STRUCTURE INTO ENSURE • ...' STRAP TIES ENGAGEMENT DS-1 (ENDS ON DS-1 WITH SPRINKLER ru SHOWN WITH OPPOSING SS AND RHOWN IDH WRENCHING AREA STANDARD SIDES OF ESCUTCHEON - ESCUTCHEON BOOT) FIGURE 14 FIGURE 15 FIGURE 16 MODEL DSB-2 SPRINKLER MODEL DSB-2 SPRINKLER W-TYPE 7 BOOT WITH PENDENT SERIES BOOT WITH SIDEWALL SERIES SPRINKLER DS-1 DRY SPRINKLER DS-1 DRY SPRINKLER WRENCH TFP510 Page 7 of 10 meet the requirements of the Design Temperatures for Heated Areal Criteria section. Refer to the Design Criteria section for other important Ambient Temperature 40°F 50°F 60°F requirements regarding piping design Exposed to (4°C) (10°C) (16°C) and sealing of the clearance space Discharge End of Sprinkler Minimum Exposed Barrel Length2, around the Sprinkler Casing. Inches Do not install any bulb-type sprinkler (mm) if the bulb is cracked or there is a loss 40°F of liquid from the bulb. With the sprin- (4°C) 0 0 0 kler held horizontally,a small air bubble should be present.The diameter of the 30°F air bubble is approximately 1/16 inch (-1°C) 0 0 0 (1,6 mm)for the 135°F(57°C)rating to 20°F 4 1/8 inch(3,2 mm)for the 286°F(141°C) (-7°C) (100) 0 0 rating. 10°F 8 1 • A leak-tight 3/4 inch NPT sprinkler (-12°C) (200) (25) 0 joint should be obtained by applying a minimum-to-maximum torque of 0°F 12 30 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). (-18°C) (305) (75) • A leak-tight 1 inch NPT sprinkler -10°F 14 4 1 joint should be obtained by applying (-23°C) (355) (100) (25) a minimum-to-maximum torque of 20 to 30 ft.-lbs.(26,8 to 40,2 Nm). -20°F 14 6 3 Higher levels of torque can distort the (-29°C) (355) (150) (75) sprinkler Inlet with consequent leakage -30°F 16 8 4 or impairment of the sprinkler. (-34°C) (405) (200) (100) Do not attempt to compensate for -40°F 18 8 4 insufficient adjustment in an Escutch- (-40°C) (455) (200) (100) eon Plate by under or over-tightening the sprinkler. Re-adjust the position of -50°F 20 10 6 (-46°C) (510) (255) (150)(-46°C) sprinkler fitting to suit. Step 1. Install pendent sprinklers only -60°F 20 10 6 in the pendent position, and install (-51°C) (510) (255) (150) upright sprinklers only in the upright position.The deflector of a pendent or Notes: upright sprinkler must be parallel to the 1. For protected area temperatures that occur between values listed above,use the next ceiling. cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph(18,6 kph). Install horizontal sidewall sprinklers in the horizontal position with their cen- TABLE C terline of waterway perpendicular to EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS the back wall and parallel to the ceiling. .. MINIMUM RECOMMENDED LENGTHS Ensure the word"TOP"on the Deflector faces the ceiling. Table C to determine a sprinkler's can occur that might damage the dry- Step 2. With a non-hardening pipe- appropriate exposed barrel length to type sprinkler and/or prevent proper thread sealant such as TEFLON tape prevent water from freezing in the con- operation in a fire situation. applied to the Inlet threads, hand- necting pipes due to conduction. The Use of the Model DSB-2 Dry Sprin- tighten the sprinkler into the sprinkler exposed barrel length measurement kler Boot,described in Technical Data fitting. must be taken from the face of the Sheet TFP591 and shown in Figures 14 sprinkler fitting to the surface of the and 15,can provide the recommended Step 3. Wrench-tighten the sprinkler structure or insulation that is exposed seal. using either: to the heated area. Refer to Figure 11 • a pipe wrench on the Inlet Band or for an example. Installation the Casing (Ref. Figures 1 and 2) Clearance Space • the W-Type 7 Sprinkler Wrench on In accordance with Section 8.4.9.2 of The TYCO Series DS-1 Dry Type Sprin- the Wrench Flat(Ref. Figure 16) the 2010 edition of NFPA 13,when con- klers,5.6K Pendent,Upright,and Hori- necting an area subject to freezing and zontal Sidewall,Quick Response(3 mm Apply the Wrench Recess of the an area containing a wet pipe sprinkler bulb) and Standard Coverage must W-Type 7 Sprinkler Wrench to the system, the clearance space around be installed in accordance with this Wrench Flat. the sprinkler barrel of Dry-Type Sprin- section. klers must be sealed. Due to tempera- ture differences between two areas,the General Instructions potential for the formation of conden- The Series DS-1 Dry-Type Sprinklers sation in the sprinkler and subsequent must only be installed in fittings that ice build-up is increased. If this con- densation is not controlled,ice build-up TFP51O Page 8 of 10 Note: If sprinkler removal becomes if they cannot be completely cleaned Dry-Type Sprinklers, 5.6K Pendent, necessary, remove the sprinkler using by wiping the sprinkler with a cloth or Upright, and Horizontal Sidewall, the same wrenching method noted by brushing it with a soft bristle brush. Quick Response(3 mm bulb)and Stan- above.Sprinkler removal is easier when Care must be exercised to avoid dard Coverage, specify the following a non-hardening sealant was used damage to the sprinklers before, information: and torque guidelines were followed. during, and after installation. Sprin- • SIN: After removal,inspect the sprinkler for klers damaged by dropping, striking, Pendent—TY3935 or TY3235 damage. wrench twist/slippage,or the like,must Sidewall—TY3735 or TY3335 Step 4. After installing the ceiling or be replaced. Also, replace any sprin- Upright—TY3135 wall and applying a ceiling finish, slide kler that has a cracked bulb or that has • 5.6 K-factor on the outer piece of the escutcheon lost liquid from its bulb. (Ref. Installa- until it comes in contact with the ceiling tion Section.) • Deflector Style: or wall. Do not lift the ceiling panel out Upright, Pendent, or Horizontal ` of its normal position. The owner is responsible for the Sidewall inspection,testing,and maintenance of When using the Deep Escutcheon, their fire protection system and devices • Quick Response, Standard Cover- hold the outer piece in contact with the in compliance with this document, as age, Dry-Type Sprinkler - mounting surface(ceiling or wall).Then well as with the applicable standards • Order Length: rotate the inner piece approximately 1/4 of the National Fire Protection Asso- Dry-Type Sprinklers are furnished turn with respect to the outer piece, ciation (e.g., NFPA 25), in addition to based upon Order Length as to hold the Deep Escutcheon firmly the standards of any other authorities measured per Figures 3 through together. having jurisdiction.Contact the install- 10. After taking the measurement, ing contractor or product manufacturer round it to the nearest 1/4 inch Care and with any questions. increment. Automatic sprinkler systems are rec . Inlet Connections: Maintenance ommended to be inspected, tested, 3/4 Inch NPT, 1 Inch NPT, or ISO and maintained by a qualified Inspec- 7-R 1 The TYCO Series DS-1 Dry-Type Sprin- tion Service in accordance with local klers,5.6K Pendent,Upright,and Hori- requirements and/or national codes. • Temperature Rating zontal Sidewall,Quick Response(3 mm bulb)and Standard Coverage must be • Sprinkler Finish maintained and serviced in accordance Limited • Escutcheon Style and Finish, as with this section. Warranty applicable Before closing a fire protection system • Part Number(P/N)from Table D main control valve for maintenance For warranty terms and conditions,visit The Upright Sprinkler without an work on the fire protection system www.tyco-fire.com. Escutcheon(TY3135)is available in that it controls, obtain permission to shut down the affected fire protection Ordering 1 Inch NPT only. systems from the proper authorities Part Numbers are for 3/4 inch and and notify all personnel who may be Procedure 1 inch NPT standard order sprin- affected by this action. klers.Orders for all other sprinkler Absence of the outerpiece of an Contact your local distributor for avail assemblies must be accompanied ability.When placingan order, indicate by a complete description. Refer to escutcheon, which is used to cover a the Price List for a complete listing clearance hole, can delay the time to the full product name and Part Number of Part Numbers. sprinkler operation in a fire situation. (P/N). DS-1 Dry-Type S Sprinklers Sprinkler Wrench A Vent Hole is provided in the Bulbp Specify: W-Type 7 Sprinkler Wrench, Seat(Ref. Figures 1 and 2)to indicate When ordering TYCO Series DS-1 P/N 56-850-4-001 if the Dry-Type Sprinkler is remaining dry. Evidence of leakage from the Vent Sprinkler Boot Hole indicates potential leakage past Specify: Model DSB-2 Dry Sprinkler the Inlet seal and the need to remove Boot, P/N 63-000-0-002 the sprinkler to determine the cause of This Part Number includes one (1) leakage (e.g., an improper installation Boot, two (2) Strap Ties, and 1/3 oz. 1 or an ice plug). Close the fire protec- of Adhesive (a sufficient quantity for tion system control valve and drain the installing one boot). system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated,should be replaced TFP510 Page 9 of 10 P/N* 60 - XXX - X - XXX I I I SIN SPRINKLER ESCUTCHEON FINISH FINISHI 01 Pendent with Standard TY3935 SIGNAL WHITE Escutcheon(3/4" NPT) (Figure 3) 0 CHROME PLATED (RAL9003) • 02 Pendent with Deep TY3935 1 NATURAL BRASS SIGNAL WHITE Escutcheon(3/4" NPT) (Figure 5) (RAL9003) 03 Pendent with Recessed TY3935 2 NATURAL BRASS BRASS PLATED Escutcheon(3/4" NPT) (Figure 4) Pendent without TY3935 q SIGNAL WHITE SIGNAL WHITE 04 Escutcheon 3/4" NPT (RAL9003) (RAL9003) ( ) (Figure 6) 9 CHROME PLATED CHROME PLATED 05 Sidewall with Standard TY3735 Escutcheon(3/4" NPT) (Figure 8) Sidewall with DeepTY3735 06 TEMPERATURE SAMPLE Escutcheon(3/4" NPT) (Figure 9) RATINGS ORDER LENGTHS2 07 Sidewall without TY3735 0 135°F(57°C) Escutcheon(3/4" NPT) (Figure 10) 055 5.50" 1 155°F(68°C) 082 8.25" 36 Pendent with Standard TY3235 2 175°F(79°C) 180 18.00" Escutcheon(1" NPT) (Figure 3) 3 200°F(93°C) 187 18.75" 33 Pendent with Deep TY3235 Escutcheon(1" NPT) (Figure 5) 4 286°F(141°C) 372 37.25" 37 Pendent with Recessed TY3235 480 48.00" Escutcheon(1" NPT) (Figure 4) . 32 Pendent without TY3235 Escutcheon(1" NPT) (Figure 6) 34 Sidewall with Standard TY3335 Escutcheon(1" NPT) (Figure 8) Notes: 43 Sidewall with Deep TY3335 1. Escutcheon Finish applies to sprinklers provided with escutcheons. Escutcheon(1" NPT) (Figure 9) 2. Dry-Type Sprinklers are furnished based upon"Order Length"as measured per Figures 3 through 10,as applicable,and for each individual sprinkler where it is to be installed.After the measurement is taken,round it to the 44 Sidewall without TY3335 nearest 1/4 inch increment. Escutcheon(1" NPT) (Figure 10) " Use Prefix"I"for ISO 7-R 1 Connection(e.g.,I-60-010-4-055). 38 Upright without TY3135 Escutcheon(1" NPT) (Figure 7) TABLE D SERIES DS-1 DRY-TYPE SPRINKLERS PART NUMBER SELECTION TFP510 Page 10 of 10 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright m 2015 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of the DuPont Corporation Fire Protection Products Eddy Flow The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems systems with a working pressure of 300 psi or less. in commercial and residential construction, Bull Please check with appropriate sources for up-to-date Moose Tube has added Eddy Flow to its listings and approval information. ' comprehensive line of sprinkler pipe products. As an added benefit, it is more economical to use than Eddy Flow is a specially engineered replacement for schedule 10 due to reduced delivery costs and ease schedule 10, offering better flow characteristics while of handling. Furthermore, Eddy Flow's larger ID providing design flexibility. This product is FM provides an opportunity for downsizing and further approved, as well as UL listed (for U.S. and Canada) cost savings. for roll grooving and welding for use in fire protection COMPARISON INSIDE '. C.R.R.* Nominal Pipe Eddy Schedule 10 Schedule Size O.D. (in) .; t: ti ' �' � Eddy Flow Schedule SiE §' in in ,�in r �' 1 1/4 1.660 1.530 1.442 1.380 1.98 1.00 1 1/2 1.900 1.728 1.682 1.610 3.44 1.00 2 2.375 2.203 2.157 2.067 2.78 1.00 2 1/2 2.875 2.705 2.635 2.469 1.66 1.00 3 3.500 3.334 3.260 . 3.068 1.00 1.00 4 4.500 4.310 4.260 4.026 1.00 1.00 - * Corrosion Resistance Ratio BENEFITS • Dual Certified to ASTM A135 and A795. • FM Approved for roll grooved,and welded,and plain-end application in wet systems. • UL Listed(for U.S.and Canada)for joining by welding or by listed rubber gasketed fittings for use in wet,dry, preaction,and deluge type sprinkler systems. • UL Listed(for US and Canada)and FM Approved for use with Victaulic®FIT®Fittings in plain end applications. • Lightweight-saves shipping costs,and offers easier handling. • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. • Floor stock available in various lengths produced in Casa Grande(AZ),Gerald(MO),and Masury(OH).Also can be ordered in custom lengths.. • Can be used for wet and dry*systems. *Eddy Flow can be hot dipped galvanized to meet FM's requirement for dry systems. PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. i( 4 1819 Clarkson Road For additional information, c U� us Chesterfield,MO 63017 contact your salesperson today at uSTED BULL.MOOSE TuBE cCIANy (800)325-4467 (800)325-4467 or(636)537-2600 FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 ACOMOcompany e-mail:salesAbullmoosetube.com APPROVED AD information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Victaulic® Grooved End Fittings ✓ctaulia 07.01 x � u �e No.20 Tee No.10 Elbow Certifications/Listings cgs ® (' LPCB Fl VdS supplied as"hot dip galvanized"the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold+86°F/+30°C potable water service and ANSI/NSF 372:No.10 90°Elbow,No.11 45°Elbow,No.12 22 1/2° Elbow,No.13 11 1/4°Elbow,No.100 90°Long Radius Elbow,No.110 45°Long Radius Elbow,No.20 Tee,No.25 Tee with Grooved Branch,No.30 45°Lateral, No.60 Cap,No.50 Concentric Reducers,No.51 Eccentric Reducers. Note:The following Victaulic fittings are VdS approved:No.10 90°Elbow,No.11 45°Elbow,No.20 Tee and No.60 Cap. Note:The following Victaulic fittings are LPCB approved:No.10 90°Elbow, No.11 45°Elbow,No.12 22 1/2°Elbow,No.13 11 1/4°Elbow,No.30 45°Lateral, No.30-R Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Product Description • Wide range of fittings from 3/a—60'/20— 1500 mm • Fittings conform to the pressure ratings of the Style 77 coupling • Fittings are provided with grooved or shouldered ends. Note:These fittings are not intended for use with Victaulic plain end couplings. • Fittings are intended for use in grooved piping systems only Note:When connecting wafer or lug type butterfly valves directly to Victaulic fittings using Style 741 or 743 flange adapters,be sure to check disc clearance dimensions with I.D.dimension of fitting. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By I Date _IL Date victaulic.com I Fittings I Grooved End I Publication 07.01 07.01 1449 Rev Y Updated 03/2015 ©2015 Victaulic Company.All rights reserved. 1 ✓ctaulic' victaulic.com Flow Data (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/2°elbow is approximately one-half the resistance of a 45°elbow. Values of mid-sizes can be interpolated. Size Dimensions 90°Elbows 45°Elbows 1 Tees No. 100 No.110 Actual Outside No. 10 11/2 D Long No. 11 11/2 D Long Nominal Size Diameter Std.Radius Radius Std.Radius Radius Branch Run inches inches feet feet feet feet feet feet mm mm meters meters meters meters meters _ ! meters 1 1.315 1.7 _ 0.8 4.2 1.7 25 33.7 0.5 0.2 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 50 60.3 1.1 0.8 0.5 0.3 2.6 1.1 76.1 mm 3.000 4.3 - 2.1 _ 10.8 43 76.1 1.3 0.7 - I 3.3 1.3 3 3.500 5.0 3.8 2.6 1.6 13.0 ! 5.0 80 88.9 1.5 1.2 0.8 , 0.5 ! 4.0 1.5 108.0 mm 4.250 6.4 _ 3.2 - 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 100 I 114.3 L.- 2.1 1.5 1.0 1.- - 0.6 4.9 2.1 ..-_ 133.0 mm 5.250 8.1 _ j 4.1 _ 20.0 8.1 133.0 2.5 _ .. 1.2 6.2 2.5 139.7 mm I 5.50139.07 I 8.52.6 I - 4.2 - 21.0 8.5 1.3 6.4 2.6 5 1 5.563 8.5 _ 4.2 ! _ 21.0 8.5 125141.3 2.6 1.3 6.4 2.6 159.0 mm 6.250 9.4 _ 4.9 - 25.0 9.6 159.0 2.9 1.5 7.6 2.9 165.1 mm 6.500 9.6 _ 5.0 - 25.0 10.0 165.1 2.9 1 1.5 7.6 3.0 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 200 219.1 j 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 I 300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 14 14.000 24.5' 15.8 i 18.5' 11.0 70.0 23.0 F 350 355.6 t- 7.5 4.8 5.6 3.4 21.3 7.0 16 16.000 28.0' 18.0 21.0' 13.0 80.0 27.0 400 406.4 8.5 5.5 6.4 4.0 24.4 8.2 18 18.000 31.0' 20.0 23.5' 14.0 90.0 30.0 450 457.0 9.5 6.1 7.2 F 4.3 27.4 9.1 20 20.000 34.0' 22.5 25.5' 16.0 100.0 33.0 800 508.0 10.4 6.9 7.8 4.9 30.5 10.1 24 24.000 42.0' 27.0 29.5' 19.0 120.0 40.0 600 { 610.0 12.8 8.2 _1_- 9.0 5.8 36.6 L - 12.2 AGS fittings available up to 60"11500 mm.Contact Victaulic for details. AGS" 1 Fitting flow data for 14-24"/350-600 mm size No.10 and No.11 Elbows is based on fittings for Style 07 and 77 couplings.For flow data on AGS fittings(No.W10 and No.W11 Elbows),refer to puolicatlor 20.05. 07.01 1449 Rev Y Updated 03/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic victaulic.com �to CtoE---1 EtoE i~C to E l 1 ., I II i Eiss <ilt C to , ' - <, CtoE Ct E M , to E No.10 No.11 No.12 No.13 No.100 No.110 Standard and GSNK No. 100 No. 110 No. 10 No. 11 No. 12 No. 13 90°Long Radius 45°Long Radius I Size - 90°Elbow 45°Elbow l _- 221h°Elbow 111/4°Elbow Elbow Elbow Actual Approx. Approx. Approx. Approx. Approx. T Approx. Outside Wgt. Wgt. Wgt. Wgt. Wgt. Wgt. Nominal Size Diameter C to E Each C to E Each C to E Each C to E Each C to E Each C to E Each inches inches inches lbs. inches lbs. inches lbs. inches lbs. inches j lbs. inches lbs. mm mm mm kg mm kg _..mom- kgmm kg mm kg mm kg .. 6.250 6.50 18.6 3.50 10.8 i _ 159.0 mm _ _159.0 165 8.4 89 4.9 - - - 165.1 mm 6500 6.50 15.5 3.50 9.8 3.13 11.4 2.00 7.4 10.75(sw), 29.0 5.50(sw) 19.0 165.1 165 7.0 89 4.4 79 5.2 51 3.4 273 13.2 140 8.6 8 8.625 7.75 29.9 4.25 ! 20.4 7.752 20.0 2.00 10.114.25 66.0 7.25 36.0 L 200 219.1 197 ; 13.6 108 9.3 197 9.1 51 4.6 362 f 30.0 184 16.3 10 10.750 9.00 i 63.3 4.75 37.5 4.38(sw) 30.0 2.13 11.8 15.00 107.0 I 6.25 57.0 250 273.0 229 28.7 121 17.0 111 13.6 54 5.3 381 48.5 159 25.9 12 12.750 10.00 74.0 5.25 66.7 4.88(sw)I 40.0 2.25 29.3 18.00 156.0 7.50 90.0 300 323.9 254 33.6 133 30.3 124 18.1 [ 57 13.3 457 70.8 4 191 40.8 143 14.000 14.00 136.0 5.75 65.0 5.00(sw) 46.0 3.50(sw) 32.0 21.00(s)i 164.0 8.75 82.0 !, 350 a 355.6 356 61.7 146 295 127 20.9 89 14.5 533 74.4 222 37.2 14.843 14.84 149.3 6.13 82.0 377.0 mm° C 377.0 377 67.7 156 37.2 - - - - - - - - 163 16.000 16.00 171.0 6.63 88.0 5.00(sw) 58.0 4.00(sw)-k- 42.0 24.00(s) 210.0 10.00(s) 100.0 400 406.5 406 j 77.6 168 39.3 ( 127 26.3 102 19.1 610 95.3 254 [ 45.4 16.773 16.75 198.6 7.00 101.3 _ _ 426.0mm4 - _ _ 426.0 425 90.1 178 45.9 - - 18' 18.000 18.00 228.0 7.50 108.0 5.50(sw); 65.0 4.50(sw) 53.2 27.00(s) 273.0 11.25(s) 135.0 450 457.2 457 103.4 190 50.0 140 29.5 144 24.1 686 123.8 286 61.2 480.0 mm' 18.898 18.88 291.0 7.83 141.7 _ _ _ _ _ 1 480.0 480 132.0 200 64.3 - 20 20.000 20.00 298.0 8.25 138.0 6.00(sw) 78.6 5.00(sw) 65.0 30.00(s)' 343.0 12.50(s) 174.0 500 508.0 508 135.2 210 62.6 152 36.0 127 295 762 155.6 318 78.9 20.866 20.88 355.0 8.63 179.0 530.0 mm° _ _ _530.0 530 161.0 219 81.2 - - - - 24 3 24.000 24.00 438.0 10.00 221.0 7.00(sw) 140.0 6.00(sw) 60.0 36.00(s) 516.0 15.00(s) 251.0 600 609.6 610 198.7 254 100.2 178 635 152 2.7.2 914 234.1 381 1.13.9_ 630.0 mm 4 24.803 24.80 545.0 10.25 255.2 630.0 630247.2 261 115.7 -I For AGS fitting information,see publication 20.05 14-60 GS-2350-1500 AGS- -1....#- 2 Gooseneck design,end-to-end dimension fittings in this size,contact your nearest Victaulic sales representative. 3 For 147350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. 4 Chinese standard sizes General Notes Note,All fittings are ductile iron unless otherwise noted with an(sw)or(s). (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded 07.01 1449 Rev Y Updated 03/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaul.C' victaulic.com _. Tees,Crosses and True Wyes No. 20 Tee No. 35 Cross No. 33 True Wye No. 29M Tee with Threaded Branch CtoE N-CtoEl �� �oLE ^ cto GE-1 11,11 C II �1 EE Certo C to TE SE 1 No.20 No.35 No.33 No.29M No.20 i No.35 f No.33 No.29M Size Tee Cross(sw) j True Wye(sw) Tee with Threaded Branch Approx. Approx. Approx. I Approx.- Actual Outside Weight Weight Weight j Weight Nominal Size Diameter C to E Each C to E Each C to LE C to SE Each C to GE C to TE Each inches inches inches lbs. inches lbs. inches inches lbs. inches inches lbs. mm mm mm kg mm kg mm mm j kg mm mm kg 3/4 1.050 2.25 0.6 2.25 0.9 2.25 2.00 0.7 2.25 2.25(sw) 0.6 20 26.9 57 0.3 57 0.4 57 51 0.3 57 57 0.3 1 1315 2.25 1.0 2.25 1.3 2.25 2.25 1.1 2.25 2.25 1.0 25 33.7 57 0.5 57 0.6 57 57 0.5 57 57 0.5 1,/4 1.660 2.75 15 2.75 2.1 2.75 2.50 1.5 2.75 2.75 1.5 32 42.4 70 0.7 70 1.0 70 64 0.7 70 70 0.7 11/2 1.900 2.75 2.0 2.75 2.5 2.75 2.75 1.8 2.75 2.75 2.0 40 48.3 70 0.9 70 I 1.170 70 0.8 70 70 0.9 2 2.375 3.25 3.0 3.25 3.8 1 3.25 T 2.75 2.5 3.25 4.25 3.0 50 60.3 83 1.4 83 1.7 83 70 1.1 83 108 1.4 21/2 2.875 3.75 4.3 3.75 6.1 3.75 3.00 4.3 3.75 3.75 j 4.3 65 73.0 95 2.0 95 2.8 95 76 2.0 95 95 2.0 76.1 mm 3.000 3.75 5.2 - - - - - 3.75 3.75(sw) j 5.2 76.1 95 2.495 95 j 2.4 3 3.500 4.25 6.8 4.25 10.5 4.25 3.25 6.1 4.25 6.00 6.8 80 88.9 108 3.0 108 4.8 108 83 2.8 108 152 L 3.1 31/2 4.000 4.50(sw) 7.9 4.50 11.5 4.50 3.50 9.6 4.50 4.50(sw) 7.9 90 101.6 114 3.6 114 5.2 114 89 4.4 114 114 3.6 108.0 mm 4.250 5.00 15.5 _ - 5.00 5.00(sw) 15.5 108.0 127 7.0 - - - 127 127 7.0 4 4500 5.00 11.9 5.00 15.8 5.00 3.75 9.8 5.00 7.25 11.9 100 114.3 127 5.4 127 7.2 127 95 4.4 127 184 5.4 41 5.000 5.25(sw) 15.0 5.25 18.5 5.25 5.25(sw) 15.0 120 127.0 133 6.8 133 8.4 - - - 133 133 6.8 133.0 mm 5.250 5.50 17.8 - - - - _ 5.50 5.50(sw) 17.8 133.0 140 8.1 140 140 8.1 139.7 mm 5.500 5.50 17.8 _ - - _ _ 5.50 5.50(sw) 17.8 139.7 140 8.1 140 140 8.1 5 5563 5.50 17.8 5.50 20.0 550 4.00 15.0 5.50 5.50(sw) 17.8 125 141.3 140 8.1 140 9.1 140 102 6.8 140 140 8.1 6.250 6.50 27.1 _ 159.0 mm - _ - 650 6.50(sw) 27.1 - 159.0 165 12.3165 165 12.3 165.1 mm 6.500 6.50 22.0 6.50 28.0 _ 6.50 6.50(sw) 22.0 ' 165.1 165 10.0 165 12.7 - 0- L _ 165 165 10.0 6 For 14'/350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. 7 Chinese standard sizes 07.01 1449 Rev Y Updated 03/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaulic` victaulic.com Cap .t. No. 60 tr No.60 No.60 Size No.60 Cap Actual Outside rApprox.Weight No.60 r Nominal Size Diameter "T"Thickness ( Each Size Cap inches inches inches lbs. Actual Outside 'Approx.Weight( mm mm mm kg Nominal Size Diameter "T"Thickness Each 6.250 1.00 ; 6.8 inches inches 159.0 mm inches lbs. 159.0 25 3.1 mm mm mm kg -- i 165.1 mm 6.500 1.00 i 7.3 3/a 1.050 ( 0.88 0.2 165.1 25 3.3 20 26.9 22 0.1 6 6.625 1.00 6.1 1 1.315 0.88 0.3 150 168.3 j 25 2.8 25 33.7 22 0.1 8 8.625 1.19 13.1 1P/a 1.660 0.8811; 0.3 200 219.1 30 5.9 32 42.4 22 0.1 10 10.750 1.25 21.0 11/2 1.900 0.88 0.5 250 273.0 32 9.5 40 48.3 22 0.2 12 12.750 ( 1.25 35.6 2 2375 0.88 0.6 300 323.9 32 16.2 50 60.3 22 0.3 1413 14.000 9.50(s) 21/2 2.875 0.88 1.0 350 355.6 241 65 73.0 22 0.5 161' 16.000 10.00(s) 76.1 mm i 3.0001 76.1 .88 1.2 400 406.4 254 + - - 22 0.5 1813 18.000 11.00 0(5) 3 3.500 - 0.88 1.2 450 457.0 279 + 88. 80 0.5 I 2413 24.000 13.50(s) 311/z 4.00.00 0 j 0.8.8 8 2.5 500 508.0 305 90 101.6 22 1.1 4.250 1.00 2.3 600 610.0 343 + 108.0 mm �._ t---- 108.0 25 1.0 For AGS fitting information,see publication 20.05 4 4.500 1.00 2.5 14-60 w 100 114.3 25 1.1 350-1500 AGS- 133.0 mm 5.250 1.00 4.5 133.0 25 2.0 13 For 14"/350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove 5.500 1.00 4.5 139.7 mm 139.7 25 2.0 fittings in this size,contact your nearest Victaulic sales representative. 5 5563 1.00 4.6 General Notes 125 141.3 25 2.1 No.60 cap is not suitable for use in vacuum service with Style 72 or 750 13 For 14"/350 mm and larger roll grooved systems,Victaulic offers the couplings.No.61 bull plugs should be used. Advanced Groove System(AGS).For pricing and availability of cut groove Note:All fittings are ductile iron unless otherwise noted with an(sw)or(s). fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded +Contact Victaulic for details. 07.01 1449 Rev Y Updated 03/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 16 ictaulic' Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL L PIPES GI-I (lbs/ft) (in) XsuNDLE S1zE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 • 1 1/2 .2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIP SIZE(in) SCHEDULE 40 EDDYTHREAD 4 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems • :.. ,. � s, ems_ . . �� 1819 Clarkson Road For additional information, Chesterfield,MO 63017 contact your salesperson today at c (L us Ll II BULL NSE TUBE Cop,,u2 ANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED -- FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 A Cf company e-mail:salesAbullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 "fr Ductile Iron Fittings - Class 300 UL/FM crus APPROVED Fig. 35E 3- 90°Elbow LISTED A Ilk ti_e_^ ; 1 SizePart Number r "A ` packing s Weight ;`�'in , R in f° ``'Inner 44"`Master:: ib'' ___+� 1/2 35E 3004 1.13 100 200 0.2 �� i '3 .,, 3 3006 ' 1.31.. 70:' 140 M, , 0.3fi" A 1 35E 3010 1.50 40 80 0.5 i� .;1'14 35E 3012 1. 5 ` ` ... 0.8 1-1/2 35E 3014 1.94 18 36 1.1 gt ,35E 802g,, ; ,, 1.72.2 .,,,:' .4;;. 10 M 20 '' 1.8„Z 2-1/2 35E 3024 2.70 4 8 3.2 "_.. - Fig. 35RE3-900 Reducing Elbow B Sq.' artaumbe '4A , ", . B Packing Weight In °, , , . .'.t'Inner; aster yR° lb III .4\ ,,,\, 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 :�x 1/a 35RE000 ,- t, 16 11 1,;36 T .70.,, .," 140 0A- 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.44 jAint x 1.1/4 x i„,,, 3 iE3 12O , . 1.34 x.53 3 , 70 0 l-• -. 1-1/4 x'3/4 35RE3012006 1.45 1.63 j 3570 ' 0.6 1-1/4 1" - 35RE3012010 ::, X1.5 1.6 3Q , ' i.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1411,31434P6r, 01 &OG5 %1.7 5 ;. 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1 -1/4141„,,,3` a '01. 12 :82 1.88. ,...m„ x.:36 ,,. 1js '' '2x 1/2 35RE3020004 1.60 1.97 18 36 1.0 x $, , RE3 0000 , ,1( 1. a, "_ 1 36 , I, 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 lit:x--i-1111 5RE , 001 °®_41, 0 ry ", ik 24 1. ti 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 W _ _ 2517' AdAAAA r ;12 '>..1 2„ 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow .�Sizew A Packing' ;x Weight A � u s Aiii ;-' x �� �, Inner� �,. Master`s .., lb f. ls, 1/2 35F 3004 0.88 150 300 0.2 ...3j4 �F 3bg-, ' ` .0.98' 80 ''''1' _`160 '' 0 ti /- -0� 1 35F3010 1.13 40 80 0.5 �� . 4 ? 35F 301T a, 1.2k. ' 2 4"" 50 . ., : .:> 0 , kiltIA 1 1/2 35F 3014 1.44 20 40 1.0 � � ' � 3 ., 02f�'t, p 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee A:Size If,fP rt j `robe " ,. 1 P cking r; Weight a: �1�01a� i in- �� � °yin Inner Master c. r lb . `A A 1/2 35T 3004 1.13 80 160 0.3 3/ 331. , 30 „ 00 0.5.4=Y 1 35T 3010 1.50 25 50 0.7 -I� II .. .0:I �. .I 1-'1/4`' ','�" 35 30j ,i-';'. x.75 ,, 1Q, X2`0 -4 -1.1 A A 1-1/2 35T3014 1.94 10e 201.5 ilir :�2 „,.....„1.1."- 0 , 2,25 w .' �_ m ..A ..Mkt ' t':4 ,,/4T 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com ' - Ductile Iron Fittings - Class 300 UL/FM c (ID us 41101> APPROVED Fig. 35RT3-Reducing Tee LISTED Lk Sizes ` kErf Number A : h;B t ' C _ ,Packing ' Weight 1 l ...in . 1. in in in Inner ,Master .Weight x C 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 �I_ '. 1 R 100 .2&` 1.267- 111r .26 1:3 0" 1Q ` 0 lli -�_ -�- 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 , .�I 1 x31 ,, x'",35,. 01005 : ;i.,38 1-1.3_86 8 .., . 45M 25F... , 50..n 0 51 R. 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A ,, 1 x 3/4x 1 T;..1 35 73 Q06.010 11.50 . 1.45 - 1.5 r 25, f 0 0.7 - 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 11/4 x 1/2741/4'1/4'.35'E 012 401 5.,. f.'&3...4. ,.1.75,, ,f 25" 50` 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 '27/4x1 4 1-147''35W°1, 16 7x62,.....„1::',1.76=-,i, .<.s. " 4b } 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 ".,;1-114.411/?:' .A„5 1T30 ®icy; ' '{ c ' t 1 5"i v ,, .:1-7,-,r,. '®;¢: 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 :.... x"1/4 x 12 ry.,,35RT 112010010 58 0 ;89 'i,2 i Ya 947 ` 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 ":1-1/2x:44: 3 3014004 ; .1.41E 11 x, 6 7yd ,167i, 3&?' 1,0F 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 x xi- ''‘ T301`41t !i4 ,,,,,,,,11/ Tr6C7 1.414,. T2 =; 4 1..2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 c 3L4 x 1-1 -T3e 0p 1 +2 `.1: .., 1.88 ' .. 40 s"'1.1 .;: 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 ;, �<x 1 :-`6, RF ..40 s � 1` , v " . 11-!,.., t!, #, y '24: 2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 -1/2 x442 35' 1 140 10001 50, 4‘,54-14.1q1,46 ' 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 : /2 x 111/4 °35 01 oo z" F82 1 7 �:80 . 1 ,w 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 x-1/2 A,` T3* i1 v 8 i$2; .88it1 r1 7*;. 1-1/2 x 1-1/4x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 14 -1/4 /4 ; RT 4'49 e -, :II?: ~ j & 'L7TH '16 itp2 ail,.0' . n" 1-1/2 x 1-1/4x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1;a xx 1.-1/4-41/4 35R f.!140ig01 I*IL1 "= x•:88 14 ',28,...„„L.,,,, 1.3. , 1-1/2 x 1-1/4x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 4 2x1' - . . ' T3.`at04 , i.. g . .. 'w, 4. 26 „y15 I { 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 x1 '.1.- a ei.moi 1 1.737 ' 2. ' 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 i1 11/4.44... RTm* 1 f 11.90\ 240k, 5 9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 442x4/2 ' ''''.w.41 .'1 s .. ,:A2 2.1 8 :` 2x 1-1/2x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 x 1 " '3/4 3 0 1 0 " 0:601 42....-: 1,9T 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 .,v2 x 1 /2 1-1/j 3 30 e®1 2 .9 182 t'E . '' t :16,,, Ili2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35RT3-Bull Head Tee Si . Furl?timbal' 'Aft C Packing Wej fit �9��.1iP '`'€ . 41 ).: iii in..r� Inner.. Master, .,_ � �C 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 17.1/4 . 5BT3010d12fx 1.58: gilqP ialp 0„, 4 x 1 x 1 1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 - f1/2 350126t00448 0 182 d 151 3 A B 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 `}r .1-1/4 24 35E ,,,11-- 0l :2..10 .. .° u �.,_.w. 20 1.6 1-1/2 x 1-1/4, ,,,-1-1/20 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 3 T3014020 ,3116, % 06 • 2.02 t 00 ler- 1'.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 , ,: Ductile Iron Fittings - Class 300 UL/FM c (I) us 41> APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED 0 . SizeA �,•" ." Packing;o- I. Weight in .Part Number' in Inner* .0Master' lb 1/2 35CP3004 1.38 200 400 0.1 :73144 5cP3o0q- ' 16$A 1 00 ` - 0.2 1 35CP3010 1.75 60 120 0.4 1-17/11::t . ,35CP3012 :' u ,2.00 0;0 35 00 70 r0.5 1-1/2 35CP3014 2.19 25 50 0.7 ' 2:'- 5CP302 ., 2.2'''.1.' - .�0 1.2.t ': 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Jze Part Numfer A ° Packings ; Weigh Nit , in •Inner Master *,,,,.11b®1 a A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 i - 1 x 3/4 ''',:"°.:, 35RC3010006, r _ 1.69 ` ' a r 1 ' 1?2,' "."._ 0.4 t 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1(not i) 35RC30200100' ',40-2.81'°...,. : a, ,>; € `' 1:0 "- Fig. 35HB3 -Hex Bushing ��Size 4:1 i i" 11442 `, Packin,. " ., Well t B in a Y pt ber_ inner Master�t i;.,.t . 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 i1. ri , xA 35HB01or®.° 1.06 ..°,0 1Q ' 3 _ .1 fix,;IA1 1 1/4 x 1 35HB3012010 1.19 90 180 0.2 I 1-fk'1 5< 35HB 0e '•1 1.2 r 0 4 .x ""11111 1 1/2 x 1-1/4 35HB3014012 1-25 75 � 150 0.3 2x1 35H63l Dix ' "` 1.30,E 40 ,,, 4 : 80 x Y0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2"x"1-1 _ . u3 HB302014 ;' `71.38 '.. r 46*: , 8 °°00 Fig. 35SP3 -Square Head Plug Size ' "- A A '. hacking 00 A ' rt Number 41, in ,_�n :,, sinner , Masted, �, I � f'!I1 1/2 35SP3004 0.94 600 1200 0.07 AU• 35070(ill1 35SP3010 1.25 200 400 0.1 -1/4 n 3 `S„P3012 : , 7 1~,100 ' <20Qo 0,3 �.. � _ _ mom. 1-1/2 35SP3014 1.44 80 160 0.4 '441,,,,,,,, `35SP3 ,: s LSSO A. . ,00. ii `"0.6 Fig. 35U 3- Union with Brass Seat A Size ° A , 'WWPacking': eight Part Numb r : ; in tsi 4,. ins Iniiter Ma ter Ib -- 1 35U 3010 2.19 20 40 1.0 . . l if' . 00V. 1. 15 ` t03. ' 1.2 1-1/2 35U 3014 2.62 10 20 1.7 r, I I .2 ;, 3U3020 ,- 3.12 - r,;_ :,,.&)27. 4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Victaulic® FirelockTM Rigid Coupling 4tui.cr Style 009N 10.64 Patented 1.0 CERTIFICATION/LISTINGS LPCB C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Hot dipped galvanized Gasket: (specify choicer) ❑ Grade"E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • System No. Location Spec Section Paragraph Submitted By Date I Approved Date • victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. 1 jctaulic° victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 4.0 LISTINGS/APPROVAL 2 • The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM ( Vds 1 LPCB Sch.5 Sch.10 Sch.40 Sch.5 ' Sch. 10 ( Sch.40 i inches psi psi psi psi psi psi psi 1 psi mm kPa kPa kPa kPa kPa kPa kPa kPa 11/4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 1Yz 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 I 50 2502 2517 2517 1205 2502 2502 2500 2500 21/2N/A 365 365 175 363 363 363 363 65 2517 I 2517 1205 2502 2502 2500 2500 I 761 mm N/A 365 3 N/ A N/A ! 3634 363 363 • 2517 2502^ N/A { 2500 2500 3 365 365 175 363 363 363 363 80 N/A 2517 2517 I1205 2502 2502 2500 2500 4 365 365 175 363 363 363 363 100 N/A 2517 2517 1205 2502 1 2502 2500 2500 108.0 mm N/A N/A N/A 175 363 363 1205 2502 2502 N/A N/A — — --------- 5 N/A 290 365 N/A 363 363 232 125 2000 2517 2502 2502 1600 N/A ria 1 133.0 mm N/A N/A N/A N/A 290 4 N/A N/A N/A 139.7 mm N/A N/A N/A 290 65 363 4 232 2000 25024 N/A 1600363 N/A I 159.0 mm N/A N/A N/A N/A 5024 a N/A N/A N/A 290 6 165.1 mm N/A 20006 N/A N/A 363 a N/A N/A N/A 2502 6 N/A 290 365 363 363 232 150 2000 2517 N/A 2502 2502 1600 N/A -f---- 1- 363216.0mm N/A N/A N/A N/A _ 5 , N/A N/A N/A _rt 8 ppdry pipe O (>-40°F/40°C)for continuous use in 363 363 232 N/A j 200 N/A 2000 2517 N/A 2502 2502 1600 i 2 Listed/Approved for wet and systemsfreezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic Insta€iation Manual I-009N/009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic' victaulic.com_ I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe C Size Pressure Rating cULus FM cULus j FM cULus ! FM inches psi psi inches psi psi inchespsi psi kPa kPa kPa kPa kPa kPa 300 MT .._._.!_ 1/a-2 Ya-2 EZT 1 2068 5 300 365 300 365 BLT 1 2517 /a 2 2068 2517 300 365 ---t 2068 2517 300 365 365 DF 11/4-4 2068 2517 FF 1/a 4 i 2068 2517 MLT 11/4-2 N/A 2517 — 2 300 365 5 365 DT 1/a-2 2068 2517 FLF 11/4 4 N/A z 6 ST 11/4-2 N/A 2517 }- EF 1 Ya-4 175 175 FLT 11/4-2 N/A 2517 STF 1 Ya-4 N/A 365 1206 1206 2517 —F 300 365 365 L EL 11/4-2 2068 2517 FLTL 1�Ya-2 N/A 365 TF 2Ya-4 N/A 2517 2517 1.--- ET40 1�/a 2 300 365 GL 1�/a 2 300 365 300 365 2068 2517 2068 2517 WLS 11/4-2 2068 2517 300 365 EZF 3-4 2068 2517 MF 11/4 300 365 WST 1 Ya-2 j N/A 365 —_-__s 2068 2517 2517 300 365 XL 11/4-2 2068 F 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com3 ✓ctaulic` victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 5.0 DIMENSIONS • Style 009N toi �r � j** ,z, -‘___d- ' M -�� ..__. Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) i Dimensions Pre-assembled Actual Maximum Maximum Allow. (Push On Condition) Joint Assembled Approx. Nominal Outside Working End Pipe End Bolt/Nut 9 Weight Size Diameter Pressure 7 Load 7 Separation& Size X Y X Y Z Each inches inches psi lbs. inches ( I inches inches inches inches inches inches lbs. mm mm kPa N mm No. mm mm mm -mm mm mm kg - - 1 1/a 1.660 365 790 0.102 '/a x 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 1 M 10 x 2 1 79 127 70 127 51 0.6 J 11/2 1.900 365 1035 0.102 3/ex 2 r 3.38 5.13 3.00 5.13 2.00 1.5 40 48.3 2517 4604 2.54 I M10 x 2 86 130 76 130 51 0.7 2 2.375 365 1616 0.12 'x21/2 4.00 5.63 3.50 5.63 2.00 1.9 2 50 60.3 2517 7193 3.05 M10 x 21/2 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.1212 '/8 x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 M10 x 21/2 114 156 102 156 51 1.0 76.1 mm 3.000 365 2580 0.12 2 I 'A x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 1 11476 3.05 M10 x21/2 118 152 105 156 ! 51 1.0 , 3 3.500 365 3512 0.12 Na x 21 5.13 6.75 1 4.63 6.75 2.00 2.3 80 88.9 2517 15622 3.05 2 M10 x 21/2 130 171 117 171 51 I 1.0 4 4.500 365 5805 0.172 3/8x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 100 114.3 2517 25822 4.32 M10 x 21 152 200 143 191 54 1.3 108.0 mm 4.250 365 5175 0.17 2 '/e x 21/2 1 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 - 23020 4.32 M10 x 21h 152 1.87 137 187 54 1.4 5 I 5.563 365 8870 0.17 2 1h x 3 i 7.25 9.25 6.75 9.13 2.25 5.0 125 I 141.3 2000 39456 4.32 M12 x3 1 184 235 171 232 57 2.3 133.0mm 5.250 365 7897 0.17 2 1/2 x 3 I 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 M12 x 3 1 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 2 1 x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 2517 38529 4.32 M12 x 3 175 235 171 232 57 2.2 159.0 mm 6.250 365 11192 0.17 1h x 3"A 7.88 10.00 738 9.88 2.25 5.6 159.0 2517 49753 I 4.32 12 M12 x 31/4 200 254 187 251 57 2.5 165.1 mm 6.500 365 12105 0.17 1 x 3 1/a 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 'M12 x 3 1/a 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 1h x 31/a 8.38 10.38 7.88 10.13 2.25 6.0 I 150 168.3 2000 44469 432 2 M 12 x 3 1/2 213 264 200 257 57 2.7 216.0 mm 8.500 365 1 20712 0.17 2 Nix 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 I 55968 4.32 M16 x 4 270 337 260 257 67 5.2 8 8.625 365 21326 0.17 %x4 10.88 13.38 10.25 13.13 2.50 11.4 200 219.1 1620 94863 4.32 2 M16x4 276 340 260 333 64 5.2 7 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZT"'couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZTm Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTM couplings are supplied with FireLock EZTM Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-SealTm gaskets are not compatible and cannot be used with the FireLock EZTm couplings. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ✓otaulic° victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 6.0 REFERENCE MATERIALS Pub ca.on 05.01:Seal Selection Guide 1009N/009H:Installation Instructions FireLock EZT"Rigid Coupling • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safety,and warning instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice,or opinion from any Victaulic employee,shall be deemed to Installation alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions Reference should alwaysbe made 1-0')S Jil Ccy= of sale,installation guide,or this disclaimer. _ - db 7 P i cl hung I,sta1 f o• str_�ct ors for the product you are installing.Handbooks are included with Intellectual Property Rights each shipment of Victaulic products,providing complete installation and assembly data, No statement contained herein concerning a possible or suggested use of any material, and are available in PDF format on our website at www.victaulic.com. product,service,or design is intended,or should be constructed,to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design,or as a recommendation for the use of such material,product,service,or design in the infringement of any patent or other intellectual Trademarks property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic,FireLock EZT°,Flush-Seal°°,and Installation-ReadyTM are trademarks or or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or its affiliated entities,in the U.S.and/ countries. or other countries. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic Victaulic® Flexible Coupling Style 75 jctaulic° 06.05 rN 7. ; ‘-• N 0 °.. • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. VU 1 V Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure,resulting in serious personal injury and/or Exaggerated for clarity property damage. Approvals/Listings ® @ LPCB 0 O CB NOTICE • Victaulic RX grooving rolls must be ordered See Victaulic ui nhc .an 10.01 for details separately.They are identified by a silver color and See Victaulic pi o .:.or 02 06 for portable water approvals if applicable. the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77,the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes,the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner Engineer System No. Spec Section J. Location Paragraph Contractor Approved Submitted By i Date Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. 1 ✓ctaulic' victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Bolts/Nuts: Ductile iron conforming to ASTM A-536, grade 65-45-12. Heat-treated plated carbon steel,trackhead meeting the Ductile iron conforming to ASTM A-395, grade 65-45-15, physical and chemical requirements of ASTM A-449 and is available upon special request. physical requirements of ASTM A-183 Housing Coating: (specify choice) _' Standard: Orange enamel. 11 Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE:Additional gasket styles are available.Contact Victaulic for details. Ei Grade"E"EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. Ci Grade"T" Nitrile Nitrile (Orange stripe color code). Temperature range 20°F to+180°F/29°C to+82°C. May be specified for petroleum products, air with oil vapors,vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+66°C or for hot dry air over+140°F/+60°C. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Vic±aullc Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are • not compatible. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic' victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 I 9- mom o / SWI Dimensions Actual Maximum Maximum Allow. Approx. Nominal Outside Working ( End Pipe End Deflection from I Weight Size 1 Diameter Pressure 2 Load 2 Separation' Centerline3 Bolt/Nut° X Y i Z Each ! Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm ( kPa N mm Degrees mm/m (No.)size inches mm mm mm kg 1 1.315 500 680 0-0.060.57 238 i 4.27 1.77 13 - 25 33.4 3450 3025 0-1.6 2 43 48 j 2-44x 2 61 I 108 45 0.6 11/4 1.660 j 500 1080 0-0.060.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2°-10' 38 2-3/ex 2 68 117 45 0.6 11/2 1.900 500 1420 0-0.060.40 2.91 4.82 1.77 15 1°-56' 2-%x2 40 483 3450 6320 0-1.6 33 74 122 450.6 2 2375 500 2215 0-0.060.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1°-31 26 2-3/e x 2 87 133 48 0.8 21/2 2.875 500 3245 0-0.060.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 10-15' 22 2-4(s x 2 98 -144 48 0.9 3.000 I 500 3535 0-0.06 0.26 4.00 5.90 1.88 1.9 76.1 mm 1°-12' 2-3/4x 2 76.1 3450 15730 0-1.6 22 102 ! 150 48 0.9 A -3 3.500 500 4800 0-0.060.22 4.50 7.00 1.88 2.9 10-2' 2-1/2x23/4 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 3'/z 4.000 I 500 6300 0-0.0600-54' 0.19 2-'h x 2 3/a 5.00 750 1.88 2.9 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7950 0-0.130.34 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 1°-36' 2-1/2x2% 28 147 204 54 1.9 4.250 450 6380 0-0.130.35 5.55 7.79 2.13 3.7 108.0 mm 108.0 3100 28395 0-3.2 1.-41' 29 2-12 x 70 141 198 54 1.7 41/2 5.000 450 8820 0-0.130.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 ( 1°-26' 21 2-5/4x 3/a 156 240 54 2.5 5 5.563 450 10935 0-0.130.27 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 1°-18' I 23 2-1/4x 3'/a 175 j 256 54 2.6 • 5.250 450 9735 0-0.13 0.28 6.55 9.37 2.13 6.0 133.0mm 1°-21' 2-16x825 133.0 3100 43325 0-3.2 I 24 166 238 54 2.7 5.500 450 10665 0-0.130.28 6.80 9.59 2.13 6.3 139.7 mm 139.7 3100 47460 0-3.2 10-18' 2-5/e x 3�/a 24 173 244 54 2.9 6.000 450 12735 0-0.13 0.21 738 10.48 1.88 6.2 152.4mmi 1°-12' 2-5/ax31/4 152.4 3100 56670 0-3.2 I 18 187 266 48 2.8 6 6.625 450 15525 0-0.13 I0.23 8.00 11.07 2.13 7.0 10-5' 2-5/sx 31/4 150 168.3 3100 69085 0-3.2 18 203 54 3.2 L -- - - 159.0 mm 6.250 450 13800 0-0.13 10-9' 0.24 2-16 x 82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3.2 20 194 266 54 3.1 8 8.625 450 26280 0-0.1300-50' 0.18 2-3/4x41/4 10.34 13.97 2.13 12.4 200 j 219.1 3100 1 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by: 50%for 3/4-3 1/2"/20-90 mm;25%for 4"/100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3iataulilc victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Note Reference should always be made to the!ICC,V(la_Ar_T e e Iosta at on 4mUbor..for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. • 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ✓Ctaulic ARB N TEEL PIPE R VED PLIN ,5 ....06a$348 Reducing g� `y� g� 0C ` � FM VdS LPCB in Coupling E104-1a/05 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 750 'c The Style 750 Reducing Coupling permits direct reduction on the piping run.Designed, to replace two couplings and a reducing fitting,the Style 750 features a special reducing gasket for pressure responsive sealing.A steel washer which prevents telescoping of the t' smaller pipe inside the larger pipe during vertical systems assembly is available upon request. •11'iii Iital re MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Housing Coating:Orange enamel • Optional: Hot dipped galvanized and others Gasket:(Specify choice*): • Grade"E"EPDM (All other sizes) EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services.UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional:Assembly Washer:Galvanized,carbon steel Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com jctaulidVICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV .1 06.081 CARSON STEEL PIPE-GROOVED COUPLINGS 06.08 Reducing Coupling STYLE 750 .-- , DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Approx. Size Pressure' Max.End Load' End Sep.t Deflect.Fr.CLI No-Size Dimensions-Inches/mm Wgt.Each Nominal , . Per PIK' , She psi Lin. Celt bLIFL Alhadmm kPa. . N Inches/mrn Dem nunint Inches. X Y 2 kg *. 2 1 350 500 0-0.07 0„ 57, 0.20 3.38 5.28 1.88 2.7 2 3/8n2- 50 x 25 2410 2225 0-1.8 17 85 134 48 1.2 1½ 350 1000 0-0.070.20 3.38 5.28 1.88 2.0 0°-57' 2-3/8 x 2 40 2410 4450 0-1.8 17 85 134 48 1.0 21/2 2 500 2215 0-0.07 0 47 0.16 4.00 5.93 ' 1.88 3.1 x °- ' ' 2-3/8x 2 14 - 65 50 3450 9850 0-1.8 102 151 48 1.4 76.1mm x 2 350 1550 0-0.07 ,. 47, 0.16 4.38 6.63 1.88 4.6 2-V 2 3/ 50 2410 6900 0-1.8 ' 14 " 4 111 168 , 48 2.1 3 2 350 1550 0-0.07 0 39 0.13 4.75 7.13 1.88 4.9 x °- ' 2-1/2 x 2 4/4 80 50 2410 6900 0-1.8 11 121 181 48 22 21/2 500 3250 0-0.070 39' 0.13 4.75 7.13 1.88 4.3 °- 2-1/2x23/4 11 65 3450 14460 0-1.8 121 181 48 2.0 350 2475 0-0.07 0. 39, 0.13 4.75 7.13 1.88 4.2 88.9mm x 76.1mm 2410 2-1/2x23/4 11010 0-1.8 11 121 181 48 1.9 4 , 2 350 1550 0-0.13 i. , 0.28 6.25 8.90 2.25 8.1 100 - 50 2410 6900 0-3 2 ' 19 25 2-5/8 x 3 1/2 159 226 57 3.7 21/2 350 2275 0-0.13 . 0.28 i 6.25 8.90 2.25 8.6 65 1 2410 10125 0-3.2 -19' 25 2-5/8 x 3 A 159 226 57 3.9 3 1 500 ' 4810 0-0.13 0.28 6.00 8.90 2.25 ' 6.7 1°-19' 2-5/8 x 31/4 80 3450 21400 0-3.2 25 152 226 57 3.0 350 2475 0-0.13 , ., 19 0.28 6.25 8.90 2.25 , 6.9 114.3mm x 76.1mm , 1 2410 11014 0-3.2 ' '' ' ' 25 2-5i8 o 31/4 159 226 57 ' 3.1 5 4 350 5565 0-0.13 . 0.22 7.18 10.70 2.13 11.2 x 125 100 2410 24765 0-3.219 2-3/4x41/2 182 272 , 54 5.1 6 4 350 5565 0-0.13 0.18 8.63 11.90 2.25 16.7 150 100 2410 24765 0-3.2 x 0°-52' 15 1 2-3Ax 41/4 , 181 302 57 7.6 5 350 8500 0-0.130.18 8.31 ' 11.90 1 2.25 12.9 125 2410 37825 0-3.2 0'-52' 15 2-3Ax 4 A 211 302 57 5.9 165.1mm x 4 350 5565 0-0.13 ° 0.19 8.63 11.90 2.25 15.2 0 -55' 2-98n4¼ 100 2410 24765 0-3.2 16 219 302 57 6.9 8 y 6 350 12060 0-0.13 0. 38' 0.13 10.81 14.88 2.50 22.4 53645 0-32. - 200 - 150 2410 11 2-7/8 x 5 275 378 64 102 a 350 11610 0-0.13 0.13 10.75 14.88 2.50 23.2 219.1mm x 165.1 mm 0°-38' 2410 51645 0-3.2 11 2-7/8 x 5 273 378 64 10.5 10 8 350 20450 0- 0°-25 0.13 0.9 13.12 17.26 2.62 31.4 x ' i 2-1 x 5 1/2 273 219.1 2410 90970 0-3.2 ' 8 333 438 67 14.2 Style 750 Reducing couplings should not be used with end caps(#60)in systems where a vacuum may be developed.Contact Victaulic for details. *Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1½times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/4-31/2"/20-90 mm;25%for 4/100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. 4---Y ) 14-Z-*I Y ..1.,'-jahlgi III li4le Irmi \ ----- 1 ! ... www.victaulic.com \Ictaulic' VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.08,2 REV J CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Redticing Coupling STYLE 750 FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING Equiv.Pipe Equiv.Pipe Size Length Size Length 21 5.9 1 2 2.7 50 x 25 1.8 25 x 50 0.8 11/2 2.0 11/2 2 1.9 40 0.6 40 x 50 0.6 21/2 2 1.9 22'/z 1.0 65 x 50 0.6 50 x 65 0.3 76.1 mm x 50 0.6 76.1mm ' 1.0 03 3 2 5.5 3 3.5 80 x 50 ; 1.7 80 1.1 21/2 3.8 4 3.0 65 1.2 100 0.9 88.9mm x 76.1 mm 3.8 21/2 3 2.5 1.2 65 x 80 0.8 4 2 6.0 4 3.0 100 x 50 , 1.8 100 1 0.9 2'/z 6.0 76.1 mm x 88.9mm 2.5 65 1.8 0.8 3 6.0 114.3mm. 3.0 80 1.8 0.9 114.3mm x 76.1mm 6.1'' 3 4 2.5 80 x 100 0.8 5 4 30 45 3.3 125 x 100 0.9 100 x 125 1.0 • 6 4 6.0 6 4.6 150 x 100 1.8 150 1.4 5 4.5 I 165.1 mm 4.6 125 1.4 1.4 165.1mm x 4 6.0 5 6 2.3 100 1.8 125 x 150 0.7 8 6 7.3 6 .__ 8 6.0 200 x 150 2.2 150 x 200 1.8 219.1 mm x 165.1mm 7'3 165.1 mm x 219.1 mm 5.4 , 2.23 1.65 108 8.7 8 10 6.3 273 x 219.1 2.65 219.1 x 273 19.2 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jotaulic* REV_J 06.08 3 .CARPON STEEL PIPE—GR VED.CQUPLIN$S 8 a= g �. ` . ,k"-. Reducing Coupling STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV! UPDATED 08/2012 •Ctaul,CP VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.w 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.08 ZU Model 350ADA WILKINS Double Check Detector Assembly Application WILIONS Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of �-I 13 "°a 11 polluted water into the potable water supply. Model 350ADA $w{ " " A lik.arst, shall provide protection where a potential health hazard does 4. f lb' _ ; f y 1µe not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance(Horizontal&Vertical) (with OS&Y gates) ,SF ANSI'SA, (with BG valves) •ASSE®Listed 1048 Options •AWWA Compliant C510(with gates only),and C550 (Suffixes can be combined) • CSA®Certified 664.5 • UL®Classified ❑ - with flanged end OS&Y gate valves(standard) • C-UL®Classified ❑ L - less shut-off valves(grooved body connections) • FM®Approved ❑ LM - less water meter •Approved by the Foundation for Cross Connection ❑ - with remote reading meter - Control and Hydraulic Research at the University of ❑ - with gallon meter(standard) Southern California ❑ CFM - with cu ft meter • NYC MEA 221-04M-2(2 1/2" -8") ❑ CMM - with cu meter meter • NSF®Listed-Standard 61,Annex G* ❑ G - with grooved end connections 10.25% MAX.WEIGHTED AVERAGE LEAD CONTENT) ❑ FG - with flanged inlet connection and grooved By-Pass Backflow Assembly 3/4"Model 95OXLD outlet connection Materials ❑ PI - with Post Indicator Gate Valves Main valve body Ductile Iron ASTM A 536 Grade 4 ❑ BG - with grooved end butterfly valves with Access covers Ductile Iron ASTM A 536 Grade 4 integral supervisory switches Coatings FDA Approved electrostatic epoxy finish ❑ BF - with flanged end butterfly valves with Internals Stainless steel,300 Series integral supervisory NORYLTM,NSF Listed eg sup rviso switches Fasteners&springs Stainless Steel,300 Series Accessories Elastomers EPDM (FDA approved) ❑ Repair kit(rubber only) Buna Nitrile(FDA approved) ❑ Thermal expansion tank(Model XT) Polymers NORYLTM,NSF Listed ❑ OS&Y Gate valve tamper switch(OSY-40) Features Sizes: 2 1/2"* 3"* 4" 6",8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F —I= - =I= IMI Hydrostatic test pressure 350 PSI , f n End connections (Grooved for steel pipe) AWWA C606 ' '_- 1"r' "% - -�""'1 (Flanged) ANSI B16.1 r `' — '0.0-71' 1 Vr;!III it Uli r� o Class 125 i '��„��I'II O *2 1/2"&3"sizes use 4"body&reducer couplings ri o �a o F Dimensions&Weights(do not include pkg.) - . B C D MODEL WEIGHT A - G 350ADA LESS OSY GATE OSY GATE BUTTERFLY BUTTERFLY MODEL 350ADA with MY option SIZE SHUTOFF VALVES VALVES VALVES VALVES VALVES FLANGED GROOVED FLANGED GROOVED in. mm lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg — •.- 21/2 65 105 48 192 87 184 83 157 71 147 67 �� a ' %may fr 3 80 104 47 210 95 200 91 162 73 148 67IAI —Ir! li , � 1 4 100 91 41 230 104 204 93 147 66 139 63 Ili-iWll . IIWI 6 150 141 64 362 164 332 151 246 111 215 98 I ■ u G F 8 200 302 137 762 346 738 335 491 223 445 202 B—•1 _ 10 250 355 161 1024 464 902 409 628 285 570 259 A C o MODEL 350ADA with BG option MODEL DIMENSION(approximate) 350ADA AWITH B LESS E E WITH SIZE A BUTTERFLY GATE C D OS&YOPEN OS&Y BUTTERFLY F G VALVES VALVES CLOSED VALVES Attention: in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm Model 350ADA 21/2 65 351/8 892 321/8 816 201/8 511 41/2 114 9 229 173/4 451 153/8 391 81/4 210 6 152 71/4 184 (grooved body)and Model 3 80 361/8 918 33 838 20 1/8 511 41/2 114 9 229 20 1/4 514 17 432 81/2 216 6 152 71/4 184 350DA(flange body)have 4 100 381/4 972 331/4 845 197/8 505 41/2 114 9 229 221/2 572 181/4 464 9 229 6 152 8 203 different lay lengths. 6 150 471/4 1200 401/4 1022 257/8 657 51/2 140 101/2 267 301/2 775 241/4 616 101/4 260 7 178 10 254 8 200 62 1575 55 1397 38 1/2 978 10 254 12 305 37 940 28 1/2 724 12 305 8 1/2 216 11 279 10 250 645/8 1641 581/2 1486 381/2 978 10 254 12 305 455/8 1159 343/4 883 13 330 81/2 216 12 305 Zurn Industries,LLC I Wilkins Rev.D 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 Date:1/15 In Canada I Zurn Industries Limited Document No.BF-350ADA 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 Patent No.5,913,331 Product No.Model 350ADA www.zurn.comPage 1 of 2 Flow Characteristics O Rated Flow(established by approval agencies) MODEL 350ADA2 1/2",3"&4"(STANDARD&METRIC) FLOW RATES(Es) 0.0 12.6 25.2 37.9 50.5 C7 151 104" a. 2112"(65mm4 $ "(100mm 0 10 r —.milli. —3"(80mm) _ 69 to5 _ 35 to d 0 0 a. 0 200 400 600 800 FLOW RATES(GPM) MODEL 350ADA 6",8"&10" (STANDARD&METRIC) FLOW RATES Ills) _ _ 0.0 63.1 126.2 189.3 252.4 t 15 d 104 g 10 6"(150mm� 8"(200mm j"(250mm) 69 to 9• W CO' 5 ix -o---- 35 N W W a 0 ii 0 1000 2000 3000 4000 FLOW RATES(GPM) Typical Installation Capacity thru Schedule 40 Pipe(GPM) Local codes shall govern installation requirements. Unless otherwise specified,the assembly shall be mounted at a Pipe size 5 ft/sec 7.5 ft/sec 10ft/sec 15 ft/sec minimum of 12" (305mm)and a maximum of 30"(762mm) 2 112" 75 112 149 224 above adequate drains with sufficient side clearance for test 3" 115 173 230 346 ing and maintenance.The installation shall be made so that no part of the unit can be submerged. 4" 198 298 397 595 6" 450 675 900 1351 I 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 7:14 12" 1 .76,-3 2644 5288 . r Ill z =" O . PROTECTIVE w,.. w...1. Zi 'I�1�f, ENCLOSURE 11=11=11 O '- 1=11:�I:If•1= o �I� I=II=1 .�� .:juj i=iiil tLL.' -i c,...1 .761. I -I- . - III wil. MI ' • Tit_ IIU �_� � :3752415 I =c IIio 9����I' _ _ IIII• . IML:=11 MIN. L:=11 3"MAX. I=11- ■_ aTa // �is aZM n n- n-n --11=11. k,, II II=; II--11= =11::I is=u=1 ii=n. 11=:1111 DIRECTION OF FLOW 1111.111 �.II��11 a =Il =11. - -11= II: . ti 0 • MODEL 350ADABG(Vertical Installation) MODEL 350ADA(Outdoor Installation) Specifications The Double Check Detector Backflow Prevention Assembly shall be ASSE®Listed 1048,and supplied with full port gate valves.The main body and access cover shall be epoxy coated ductile iron(ASTM A 536 Grade 4),the seat ring and check valve shall be NoryITM(NSF Listed),the stem shall be stainless steel(ASTM A 276)and the seat disc elastomers shall be EPDM.The first and second check valves shall be accessible for maintenance without removing the device from the line.The Double Check Detector Backflow Prevention Assembly shall be a WILKINS Model 350ADA. Zurn Industries,LLC I Wilkins 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 www.zurn.com Page 2 of 2 FireLock® Check Valves Jctaul,ce Series 717 & 717H 10.08 Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted • to flanged (ANSI CL.150) equipment using either to Victaulic Style 741 Vic-Flange®or Style 744 FireLock flange adapters on either end. Series 717 Series 717 (211—3765—80 mm) (4—127100—300 mm) 100 k. Nie Series 717H High Pressure Check Valve (2-3"/50—80 mm) Approvals/Listings: c®U FM VdS LPCB LISTED See Victaulic Publication 10.01 for more details. The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD designed for hydrodynamic efficiency and available in 2750 mm —3780 mm (Series 717H)and 2 1/2"/65 mm— 127300 mm (Series 717)sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365 psi/2517 kPa. See chart below for approved services for the Series 717 valves. In both valve designs, the single-disc mechanism incorporates a spring-assisted feature for nonslamming operation. This spring-assisted, single-disc design achieves a leak-free seal with as little as 5ft/1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically (flow upwards only) or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date ----------Check Valve I Firelock®I Series 717 &717H I Publication 10.08 victaulic.com 1 ✓ctaul,c. Check Valve I Firelock®I Series 717 &717H I Publication 10.08 Material Specifications: Spring:All sizes Type 302/403 Stainless Steel Housing: Shaft Plug: Ductile iron conforming to ASTM A-536, grade • Series 717H (2—3750—80 mm): Type 416 Stainless 65-45-12. Ductile iron conforming to ASTM A-395, Steel grade 65-45-15, is available upon special request. • Series 717 (2 1/2 12765—300 mm): Carbon steel Body Coating: zinc plated Series 717H Body: Black Paint Pipe Plug: Series 717H Endface: Electroless Nickel Series 717 (2 1/2—3"): PPS Coating • Series 717H (2—3750—80 mm): carbon steel zinc Series 717 (4— 12"): Black Paint plated • Series 717 (4— 127100—300 mm): Carbon steel zinc Body Seat: plated Series 717H — Nitrile 0-ring installed into an electroless nickel plated endface Series 717 (2 ' —3"): PPS Coated ductile iron Series 717 (4— 12"): Electroless Nickel plated Disc Seal or Coating: (specify choice') ❑ Grade "T" nitrile (Series 717H Only) Nitrile(Orange color code).Temperature range—20°F to +180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. ❑ Grade "E" EPDM (Series 717 Only) EPDM (green color code).Temperature range-30°F to +230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. 1 Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H (2—3750—80 mm): CF8M Cast Stainless Steel • Series 717 (2 l/—3"): Aluminum bronze with elastomer seal • Series 717 (4— 127100—300 mm): Elastomer encapsulated disc with electroless nickel plated seat Shaft: • Series 717H (2—3750-80 mm): Brass • Series 717 (2 1—3"): Type 416 Stainless Steel • Series 717 (4— 127100—300 mm) Type 316 Stainless Steel • victaulic.com 2 ✓ctaulic Check Valve I Firelock!I Series 717 &717H I Publication 10.08 -------- ---------- --------- ------.-- Approval/Listing: Approval/Listing Service Pressures Series 717H Size cULus FM LPCB Vds 2/50 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 2'h"/65 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 76.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 3780 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517kPa 4"/100mm n/a n/a n/a n/a 5/125 mm n/a n/a n/a n/a 139.7 mm n/a n/a n/a n/a 6"/150 mm n/a n/a n/a n/a 165.1 mm 1 n/a n/a n/a n/a 8"/200 mm n/a n/a n/a n/a 10/250 mm n/a n/a n/a n/a 12"/300 mm n/a n/a n/a n/a Approval/Listing Service Pressures Series 717 Size — cULus FM LPCB Vds 2'/50 mm n/a n/a n/a n/a 21/2765 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa n/a 76.1 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 3"/80mm up to 250 psi/1725kPa n/a up to 365 psi/2517kPa up tol6bar/232psi 4'/100 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 5'/125 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517kPa n/a 139.7 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 6"/150 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 165.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517kPa n/a 8'/200 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 348 psi/2400 kPa up to 16bar/232 psi 107250 mm up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a 12"/300 mm up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a victaulic.com 3 ✓ctauljc° Check Valve I Firelock®I Series 717&717H I Publication 10.08 - . Dimensions-Series 717: < A R !...- A ‘i I AN + egillrldie ,t, - , t fa' Z [k II __ r--(7 P limit c _., „,, ,,„ MI D t 1 11 _7.} 1 i II all 1 E -_.* 14-A---1 *-B _r.- 6 I k--i(--0.1 .. 0 i i to tB--> ->i J IF 0 *-B -,..74-.1/2"NPT Upstream Drain 0 l/z"NPT Upstream Drain al . 0 0 ,/2"NPT Downstream Drain 0 1/2"NPT Downstream Drain 0 2"NPT(Drain Optional) Typical 2'h-3"/65-80 mm Typical 4-87100-200 mm Typical 10-127250-300 mm , Actual Dimensions i Approx. 1- 7 f I- Nominal Outside E to E I Weight Size Diameter A B C D 1 E J K P R Each inches inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm mm mm mm mm mm mm kg 2½ 2.875 3.88 4.26 3.57 _ _ _ _ _ 3.6 65 73.0 99 108 91 1.6 3.000 3.88 4.26 3.57 - 3.6 76.1 mm - - - 76.1 99 108 91 1.6 3 3.500 4.25 5.06 4.17 _ _ - 4.5 80 88.9 108 129 106 2.0 4 4.500 9.63 6.00 3.88 2.75 350 2.00 4.50 350 335 20.0 100 114.3 245 152 99 70 89 51 114 89 85 9.1 5 5.563 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 125 1413 267 173 114 106 55 149 104 101 12.3 5.500 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 139.7 mm 139.7 267 173 114 106 55 149 104 101 12.3 6 6.625 11.50 8.00 5.00 4.50 238 6.67 4.73 3.89 38.0 150 1683 292 203 127 114 61 169 120 99 17.2 1=1 _ 450 2.38 6.67 4.73 3.89 38.0 6.500 11.50 8.00 5.00 165.1 292 203 127 114 61 169 120 99 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 10.750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6.73 100.0 250 273.0 432 305 180 151 170 55 277 171 _ 45.4 12 12.750 19.50 14.00 8.06 ---1 6.91 7.64 2.51 12.81 7.73 - 140.0 300 323.9 495 356 205 176 1 194 64 925 196 63.5 Dimensions-Series 717H: 1Mill.C 11116 Ill 1111111.111 ' D ..--R ' J Typical 2/50 mm-3/80 mm Dimensions Approx. Nominal E to E Weight Size A B C D E J K P R Each inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm mm mm mm mm mm kg 2 8.66 6.46 3.23 1.48 3.02 2.80 _ 4.25 10.7 50 219.8 164.1 82.1 37.5 76.7 71.0 108.0 4.9 2½ 9.37 6.94 331 1.66 3.40 3.38 _ 4.38 13.8 65 238.0 176.3 84.1 42.2 86.4 85.9 111.3 63 937 6.94 3.31 1.66 3.40 3.38 438 13.8 76.1 mm - - 238.0 1763 84.1 42.2 86.4 85.9 111.3 6.3 3 9.62 1 7.44 3.53 1.91 3.65 3384.63 20.0 80 , - - 244.3 189.0 89.7 48.5 92.7 85.9 1 L_ 117.6 9.1 victaulic.com 4 jctaullic° Check Valve I Firelock®I Series 717 &717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. S717H/717HR 10 6 a N ' a I 10 100 1000 Flow—GPM S717H/717HR 100.00 z s ill S-gr a ;t' � I ? f \ ,^oFe I I; 0.00 \ ti p R h} ti ' . C ® N a. i .. ... .y.. ., i 3 1 1.00 _. ., ...„ •,.'.. .. _ u 10 100 1000.., 10000_ 100000 Flow Rate—Litres/min. victaulic.com 5 ✓ctaulic° Check Valve I Firelock®I Series 717&717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. 5717/717R 1::11i f 1 i s ._ 1e RF �� rya �h. I �� �I '._ nt � 8 F FF o �� 1 13 i I i I 3 + « ry 3r 10 100 1000 10000 100000 Flow—GPM S717/717R 10 s ;I -1 F F .._ I- 3 I { � F i « S 1 I ',A. ' 1y\ .y o , ,. I ' 1 ti 10 100 1000 10000 100000 Flow—GPM Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and FireLock are registered trademarks of Victaulic Company. 10.08 1479 Rev.R Updated 05/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 lictauliC Fire Department Connection 1 49 90° Pattern P P I® Description p The 90 Degree Fire Department Connection is Underwriters' Laboratories �. listed and Factory Mutual Approved. Manufactured from solid brass* components to increase service life. The single clapper design features brass* • clapper and brass seats within a cast brass body. The 21" swivels are pin lug Y ..' design for ease of use and compatibility with local fire service districts. Swivel gaskets are included. 4 j Installation Specifications Installation of the Fire Department Connection is achieved with readily available job site tools. Prior to installation make sure the proper identification sign has Size: 4"IPS Inlet been installed on the nipple. Coat male threads of 4" IPS nipple liberally with (2)21"Swivel Outlets a suitable pipe thread sealant such as Pipefit®.Tighten FDC one full turn past hand tight. Make sure FDC is aligned according to requirements. Type: 90 Degree Pattern DO NOT OVER TIGHTEN.OVERTIGHTENING MAY CAUSE SEVERE Material: STRETCHING AND POSSIBLE CRACKING OF THE OF THE FDC BODY. Brass*, Swivels: - NST 3.0686 x 7'/z T BCT 3.0000 x 8 TP CF r'2.9900 x`7'/z T CIN new �'�3.0580 x 6 TP CIN-old 3.0930 x 6 TP CLV 3.0780 x 8 TP DET 3.1250 x 71A T Dayton 3.2340 x 6 TP NovaSco 3.2300 x 5 TP NYFD 3.0300 x 8 TP ONT 3.1250x5TP PHX 3.0620 x 6 TP QST 3.0310x7TP Raleigh 3.3400 x 6 TP Richmon 3.3120 x 8 TP TEM 3.0750 x 6 TP Approvals: UL Listed 300psi FM Approved 300psi 3198 LIONSHEAD AVE CARLSBAD, CA 92010 *Contains lead.Not for use in water systems intended for human TEL+1 760 599-1168 consumption. +1 800 344-1822 FAX+1 800 344-3775 O 2012 Fire Protection Products,Inc. I _O LISTED APPROVED 11 11 11. 1 Brass Ball Drip Valve41* w Description The solid brass* ball drip is a "ball" type check valve. When properly installed, the internal ball rests in the lower most area of the valve body allowing for proper drainage of moisture accumulation. Upon system pressurization, the internal ball is "pushed" into the small end of the ball drip body i$ closing the opening. When system pressure is removed, the $peCiCatlOnS ball returns to its original position. One of the most common °Type moi= n uses is on the dry side of the Fire Department Connection Straight Pattern .: valve. This use helps keep moisture from accumulating inside riak the Fire Department Connection. Designed for horizontal VlaBody: Body Brass" installation only. k,Ball:13/ass Installation Standard finishes. Rough`Brass* . Proper installation of the hand tight. Finish tightening brass ball drip can be accom- with a pipe wrench up to one Adjustment anger plished with standard piping full turn. Do not over tighten. ''A' '/" ►NPTx installation tools. Make sure Over tightening may dam- ; FireLock® Buterfly Valve 4tauIicr Style 705 with Weatherproof Actuator 10.81 Material Specifications: ! Body: Ductile iron conforming to ASTM A-536, grade 65-45-12 End Face, 2 —6"150— 150 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer, 8— 127200—300 mm: Ductile iron ' conforming to ASTM A-536, grade 65-45-12 Approvals/Listings: Coating: Black alkyd enamel cus FM vds LPCB Disc: Ductile iron conforming to ASTM A-536, grade LISTED #G410001 1041/04 65-45-12, with electroless nickel coating conforming to See V tac t PLb ca-on 10.01 for more L-ails. ASTM B-733 Seat: Product Description: ❑ Grade "E" EPDM The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a Stems:416 stainless steel conforming to ASTM A-582 ductile iron body and disc with EPDM seats. Designed for fire protection services only.Victaulic FireLock Stem Seal Cartridge: C36000 brass Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Bearings: Stainless Steel with TFE lining Contact Victaulic for details of agency approvals. Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: ❑ 2—8750—200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing ❑ 10— 127250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing Job/Owner Engineer System No. Spec Section ----- --- — -- ----- ---_ Location Paragraph Paragraph Contractor Approved Submitted By Date Date victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Approvals and Listings: - Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2"/50 mm up to 300psi/2068kPa j n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/:"/65 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3780 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4"/100 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5'/125 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6"/150 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8"/200 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12"/300 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic* victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Dimensions: 4‘4Vl1 I �n�,-• • = I /0H in1 rrillitall'• ..,- Ai i : G F E-� A11-D NOTE:OPTIONAL' Y15MM TAP AVAILABLE. CONTACT VICTAULIC FOR DETAILS. ------ ------------ - ----- _ Dimensions Actual --- Nominal Outside E to E I Size Diameter A B C D E i F G DIA H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 _ 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 _ - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 76.1 mm 3.000 i 3.77 2.28 7.54 - - 4.00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 _ 450 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 550 4.22 4.50 2.20 - - 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 _ _ 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5.88 3.35 10.88 656 6.19 6.30 2.58 133 mm - - 133.0 149.4 85.1 276.4 166.6 157.2 j 160.0 65.5 139.7 mm 5.500 5.88 3.35 10.88 - 656 6.19 6.30 2.58 - 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 159mm 6.250 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 - 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1mm 6.500 5.88 3.84 11.38 0.41 7.52 6.19 6.30 258 - 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 1.90 168.3 1683 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 I 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 323.9 323.9 I 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. - -1 I INominal I Outside Equivalent Size Diameter j mm mm Feet/m inchesinches i of pipe 2 2375 6 5060.3 1.8 2Yz 2.8756 65 73.0 I 1.8 76.1 mm 3.000 6 76.1 1.8 3 " 3.500 7 .. L _- 80 88.9 2.1 4 4.500 8 100 114.3 2.4 i 108 mm 1108 mm 8 2.4 5 I 5.563 - 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 r - 6 6.625 i 14 i 150 168.3 4.2 159 mm 159mm 14 1 - 4.3 765.1 mm 6.500 14 165.1 4.2 8 8.625 16 200219.1 4.9 -- 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulic' victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: Cy values for flow of water at+60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for Cv values Formulas for Kv values Where: Where: 4P=Q2/Cvz — i- - FI Flow4P —Q =KQx /�P /K Factor Q=C x /AP Coefficient(Flow) GPM Q( low) m/hr AP(Pressure Drop) psi AP(Pressure) bar Valve Size Full Open Valve Size Full Open Actual Actual Nominal Outside Nominal Outside Size Diameter Flow Coefficient Size Diameter Flow Coefficient inches inches C, inches inches Kc mm mm mm mm 2 2.375 2 2375 50 60.3 170 50 ( 60.3 147 21 2.875 21/2 2.875 65 73.0 260 65 73.0 225 76.1 mm 3.000 260 76.1 .1 mm 3.000 225 .1 3 3.500 3 3.500 80 88.9 440 80 88.9 ( 380 4 4.500 4 4.500 100 114.3 820 100 114.3 710 108mm 108mm 820 108mm 108mm 710 5 5.563 5 5.563 125 141.3 1200 125 141.3 1040 133mm 133mm 1200 133mm 133mm 1040 5.50139.7 mm 5500139.7 1200 139.7mm 139.7 1040 6 6.625 6 6.625 150 168.3 1800 150 168.3 1560 159 mm 159 mm 1800 159 mm 159 mm 1560 165.1 mm 6.500 0 65 1800 165.1 mm 665 1560 8 8.625 8 8.625 200 219.1 3400 200 219.1 2940 10 10.750 10 10.750 250 273.0 5800 250 273.0 5020 12 12.750 12 12.750 —J 300 323.9 9000 300 323.9 7790 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 jctaulic° victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Switch and Wiring: UI LISTED JUNCTION BOX CONDUIT re/ 1. The supervisory switch contains two single pole, double throw, pre-wired switches. 2. Switches are rated: �DNDUNCONN CONNECTORS h WmENNTS 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC FIRE ALARM ro ENPof-LINE RESISTOR 0.25 amps @ 250 VDC CONTROL PANEL OR NEXTIN°°AroR SUPERVISORY CIRCUIT 3. Switches supervise the valve in the "OPEN" position. SWITCH CONTACTAATIN _. t� t� IOXAT125 AND r� 5. One switch has two#18 insulated wires per terminal, 3WVAC I. t� t� 05A AT 125VDC, Ol5 AT VDC which permit complete supervision of leads (refer BELL to diagrams and notes below). The second switch °R VOLTAGE SOURCE HORN has one#18 insulated wire per terminal. This double Switch',leads per terminal Switch 2,1 lead per terminal circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve NOTE: The above diagram shows a connection between is installed. the common terminal (yellow—S1 and yellow-with- orange stripe—S2)and the normally closed terminal 6. A#14 insulated ground lead (green) is provided. (blue—S1 and blue-with-orange stripe—S2). In this Switch #1 =S1 example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the For connection to the supervisory circuit of a UL indicator light and alarm will go out. Cap off any unused Listed alarm control panel wires (e.g. brown with orange stripe). Switch #2=S2 Only S1 (two leads per terminal) may be connected to Auxiliary switch that may be connected to auxiliary the fire alarm control panel. devices, per the authority having jurisdiction The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per Normally Closed: (2) Blue sl NFPA 70 (NEC). Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common:Yellow with Orange Stripe Installation Note Reference should always be made to the 1-10 b cta:i,c r e d Irstallat..r .=:,00k for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are Inc u.e.with each shipment o rictaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 jCtaUliGf P POTTER vsR VANE TYPE WATERFLOW e The Symbol of Protection ALARM SWITCH WITH RETARD UL,CUL and CSFM Listed,FM Approved,LPCBApproved,For CE Marked(EN12259-5)/VdS Approved model use VSR-EU Service Pressure: 450 PSI(31 BAR)-UL ,-.- Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)-UL Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive —1 'a�'• l0 mAmps min.at 24VDC P: V a ° Conduit Entrances: Two knockouts provided for 1/2"conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-13R Nominal Pipe Size Model Part Number National Fire Alarm Code NEPA-72 2" DN50 VSR-2 1144402 , 21/2" DN65 VSR-21/2 1144425 w ,.. a"I "r , C• � 3" DN80 VSR-3 1144403 • Installation must be performed by qualified personnel and in 3 1/2" VSR-3 1/2 1144435 accordance with all national and local codes and ordinances. • Shock hazard.Disconnect power source before servicing.Serious 4" DN100 VSR-4 1144404 injury or death could result. 5" - VSR-5 1144405 • Risk of explosion.Not for use in hazardous locations.Serious 6" DN150 VSR-6 1144406 injury or death could result. 8" DN200 VSR-8 1144408 es' ' Optional: Cover Tamper Switch Kit,stock no.0090148 ` TION Replaceable Components:Retand/SwitchAssembly,stock no. 1029030 Waterflow switches that are mon itoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF,deluge, or chemical suppression systems. Waterfow switches used for this application may result in unintended discharges caused by surges, trapped air,or short retard times. General Information Enclosure The Model VSR is a vane type watertlow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed and FM Approved for use on steel pipe; die-cast housing. The cover is held in place with two tamper resistant schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 mm).LPC screws which require a special key for removal. A field installable approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering cover tamper switch is available as an option which may be used Information chart. to indicate unauthorized removal of the cover. See bulletin number The VSR may also be used as a sectional waterflow detector on large 5401103 for installation instructions of this switch. systems.The VSR contains two single pole,double throw,snap action switches and an adjustable,instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV L PAGE 1 OF 4 3/09 VSR P POTFER VANE TYPE WATERFLOW e The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6"(15 cm)of a fitting which changes the direction of the waterfiow or within 24" (60 cm)of a valve or drain. NOTE:Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill(see Fig. I). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole.Roll the vane so that it may be inserted into the hole;do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow.Take care not to damage the non-corrosive bushing in the saddle.The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1).The vane must not rub the inside of the pipe or bind in any way. ,A CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty. Fig.1 Retard Adjustment DO NOT LEAVE COVER OFF FOR �44(7-,�P' AN EXTENDED PERIOD Oh Tam The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting(60-90 seconds).The time delay should be set at �1lifr_ the minimum required to prevent false alarms 1)11101 �;` \ I/ TIGHTEN NUTS �! I ,,c ,.bl'� "Sy. ALTERNATELY ,' " Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. go. � /` Correct Incorrect A MOUNT ON PIPE SO ARROW ON SADDLE 111 Philli ' POINTS DIRECTION �1OFWATERFLOW -4)--e d O C .u. �� \\l /l ___ ............___. 0.41 PP P u_‘, elle-iii ROLL PADDLE IN Ir SOmm11 OPPOSITE DIRECTION ADAPTER�_% ADAPTER DIRECTION OF OF WATERFLOW WATERFLOW (Flowing water activates I 20mm.2mm MAX. device in one direction only) DN50 ONLY .4.....) USE(2)5180162 ADAPTERS AS SHOWN ABOVE _`-// 011,4 1146-11 uwGd IN(IF Compatible Pipe/Installation Requirements Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-Bolt Nuts Size O.D. Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - 1,25+.125/-.062 33.0±2.0 VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - 20 27 VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 2.00±.125 50.8±2.0 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - _ - VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE:For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG.#5401146-REV L PAGE 2 OF 4 3/09 VSR P POTFER VANE TYPE WATERFLOW 0 The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping To remove knockouts:Place screwdriver at Break out thin section of cover when Plate Terminal, inside edge ofknockouts,not in the center. wiring both switches from one conduit 111 entrance. I llS, Ad l1i y ou00,0 DWG.#1146-16 1�'�� "���p An uninsulated section of a single conductor should not be looped `jr around the terminal and serve as two separate connections. The � �°'�1411,;." p iJl�w wire must be severed,thereby providing supervision of the NOTICE J/�` connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device Do not drill into the base as this creates NIIIIeli5.6.1146-13 inoperable risking severe property damage and loss of life. metal shavings which can create P. Do not strip wire beyond 3/8"of length or expose an uninsulated electrical hazards and damage the ' conductor beyond the edge of the terminal block.When using device.Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. Fig.5 Typical Electrical Connections BELL �_-01 ail Ira l Notes: I5__), POWER SOURCE I. The Model VSR has two switches,one canbeused to operate acentral i N SUITABLE FOR BELL station,proprietary or remote signaling unit,while the other contact E ' f E ,1 0 0 0) is used to operate a local audible or visual annunciator. 151- Cly =—� r 10 2. A condition of LPC Approval of this product is that the electrical = 1_ --,---' l o 0 01 entry must be sealed to exclude moisture. = �a\ 3. For supervised circuits,see"Switch Terminal Connections" _ —1—'7LO W ZONE it EOLR WATERFLOW FIRE PANEL drawing and warning note(Fig.4). ® i € TT`5 owa 11NAt • Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve shall always be used for test purposes.If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR is not recommended or advisable. A minimum flow of 10 GPM(38 LPM)is required to activate this device. NOTICE Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig.7 Mounting Dimensions 5.56 in (141.2 mm) Fig.8 3'501° 2.00 in GREEN GROUND (89.0 mm) (50.8 mm) f i SCREWS �I,-I ^2.34 in)��ii 1iii �•g1...,(59.4 mm Jam �).:1:11W L7-BOLT NUT PIPE DIA. Mill +5.25ni :�: �'�'_' U-BOLT WASHER VII/MM.■I (+133.4 mm) ;�,.t .;•`"11 1 iia irei1' 111 PCPE SADDLE ■ ,i ..' o Aid" El ��nu'irr.�7� PLASTIC PADDLE PIPE p, clic 1146-N % v= U-BOLT NOMINAL PIPE DIA.+1.75 in(+44.5 MM)FOR DN 50—DN 65 2-2.5 in —��• ENG 1146-15 W"' NOMINAL PIPE DIA.+2.125 in(+54.0 MM)FOR DN 80—DN 200 3-8 in PRINTED IN USA MFG.#5401146-REV L PAGE 3 OF 4 3/09 VSR POUuP RVANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found,replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable.In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig.6).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig.6) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe • 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell(if applicable). • 3. Identify and remove all wires from the waterflow switch. 4. Remove the(2)mounting screws holding retard/switch assembly to the base.Do not remove the(2)retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig.6 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUT THINS ECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING I CREWS RETARD/SWITCH ASSEMBLY 11.1111111I , „. ,, I1 l c� U ii (2)LOCATING PINS I I I • I I p (2)LOCATING PIN DO NOT REMOVE ( � - A '''• BOSSES IN BASE (2)RETARD HOUSING I ti d SCREWS PC 111115 1111 i111fl�!I�'b /I7 BASE 4ftlit o ��►� DWG#1146-10 Removal of Waterflow Switch • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG.#5401146-REV L PAGE 4 OF 4 3/09 Model 1000 APAN DRAIN® Sectional Floor Control Test and Drain Valve c us Ari>APPROVED' 3/4H 1 " 11/411 11 2" 21 !` d p ,' -, ' �' 4 �1 iM"i TEST wig; ' TESTANDRAIN ' MODEL USG t A µ a DRAIN FITTING-SPECxAL TYPE if)iartr►,r;X .x.+ K •0 li it '... ' A. S *a MiR let..Malvern.PA. ........k'..r.++r.:::: ,i;.., 1 - It ;:f,' t YM S 3 �sI WY ,:e+t,::' • The AGF Manufacturing Inc. Model 1000 TESTANDRAIN® MODEL 1000- FRONT VIEW,VERTICAL INSTALLATION provides both the test function and the express drain . function for a wet fire sprinkler system. • The Model 1000 complies with the requirements of i FROM BRANCH - NFPA-13, NFPA-13R, and NFPA-13D. hi ` • The Model 1000 TESTANDRAIN® is a compact single SYST'E`M ACCESS PORT handle ball valve which includes a tamper resistant test �od orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Ii • Available in a full range of sizes from 3/4"to 2" NPT and r I I[O� 1../11111 BSPT,with all specifiable orifice sizes 3/8" (2.8K),7/16" (4.2K), STREET EL Y2" (5.6K), 17/32" (8.0K), 5/s" (11.2K, ELO), 3/4" (14.0K, ESFR), CI) I and K25 as required by NFPA 13,2007 Edition(see reverse). ISM • The orifice size is noted on the indicator plate and the valve l�ll� features a tapped and plugged port for system access. STREET EL TO DRAIN •A locking kit is available and can be ordered with the valve OR PIPE 1 I to provide vandal resistance or prevent unintentional alarm activation. TO DRAIN l • Repair kits including (1) adapter gasket, (1) ball, (2)valve seats, (1)stem packing, and (1)stem washer are available for all TESTANDRAIN®valves.Valve and orifice size must RIGHT HAND/STRAIGHT INSTALLATION be specified when ordering. Reliability, Versatility, Code Compatibility TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS1000 10/09 Model 1000 k ) cCus TESTAN D RAI N APPROVED 300 PSI Bronze Ball Valve MODEL 1000 - PLAN VIEW FRONT VIEW - HORIZONTAL INSTALL A E =1 1 1 — O F j I 11 1/2"NESSYSTEM �g O �r tar `� ACCESS PORT F TO DRAIN ! . r� TO DRAIN `mi 1 , �L[ �—D---: I� H-- u � —I T to � G - ! 1LJ DIMENSIONS MATERIALS Orifice Size Available:3/a",7/16", 1/2", 11/22", ELO(5/a")", ESFR(3/4")",&K25"" Handle:Steel Stem: Rod Brass SIZE A B C D E F G H Ball:C.P. Brass 3� 51/16" 11/2" 23/46" 35/8" 31/8" 113/16" 406" 6W Body: Bronze (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) Valve Seat: Impregnated Teflon® 51/46" 11/2" 23/16" 35/8" 31/8" 113/16" 406" 6§/8" Handle Plate:Steel 1 1 (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) Handle Stop:Steel 57/16" 111/16" 2916" 41/4" 35/16" 115/16" 506" 51/2" APPROVALS 11/4 (163 mm) (43 mm) (65 mm) (108 mm) (83 mm) (51 mm) (141 mm) (192 mm) 67/16" 113/46" 31/4" 51/16" 37/8" 25/a" 81/4" 107/8" FM and ULC Listed(EX4019) 11/2" 67/16" Approved (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) NYC-BSA No.720-87-SM 67/16" 113/46" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" 2" (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) rr*r** *Available on 11/a" to 2"size units only "* rrr**• *• .r* ""Available on 11/2"and 2"size units only *r THE MODEL 1000 PROVIDES ALL OF THE FOLLOWING... MADE IN D.S.A. • From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1" Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)-shall be provided with a drain &8.16.2.4.3 connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location...downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice,to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1",at least one of which shall be brass. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: AG100 Quaker Lane,Malvern, PA 19355 Phone:610-240-4900 Architect: FFax:610-240-4906 Engineer: www.testandrain.com Contractor: Spare Sprinkler Head Storage Cabinet 1 49 F P P 1® Description Fire Protection Products, Inc.Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines.The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head.All six styles are manufactured with "knockouts" to accommodate • the most common size sprinklers.The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head • cabinet comes with a hinged door which remains closed to protect the spare sprinklers surfacesfrom the s and atures two holes on the back panel to allow or utilizing ot the appropriate fpf fasteners. Not intended for exposedfor ha harsh environments. st to most .ate ;..,, y fi' 11 5..... Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook.As per the 1989 Edition the correct Material., Painted Plain Steel number of spare sprinkler is as follows: finish: Red enamel 0-300 sprinklers, not less than 6;300-1000, not less than 12; 1000 or more, d not less than 24. Stock of spare sprinklers shall include all types and ratings Styles: installed.* 3 Spare sprinklers,1/2 or 3/4 6 Spare sprinklers,Y2 or.34` 6Spare, ESFR,Y2,3A or 1" Once the correct Spare Sprinkler Head Cabinet has been selected, installation 12 Spare sprinklers Y2 or l 3 is accomplished by inserting the correct fastener in each of the two holes inside 24 Spare sprinklers -"}` • i the cabinet, securing the cabinet securely to the wall.The insert the correct 36 Spare sprinklers - number and type of sprinklers in accordance with the"handbook". *Final determination is subject to approval by the AHJ. I j 3198 LIONSHEAD AVE ' CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. 111111, . . p ToLCO www.tolco.com NIBCO° Revision 5/27/2008 Component of State of Fig. 1000 - "Fast Clamp" Sway Brace Attachment California OSHPD Approved Seismic Restraints System Size Range — Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS." Pipe size used for bracing: 1" and 11/4" Schedule 40 IPS. 7 ,--- `�,. ,, c0 US LISTED "Additionally(UL) approved for use to brace Schedule 7 't sprinkler pipe up to 4" (maximum horizontal design load ' .r. �.., . \ 655 lbs.) Torque requirement 6 — 8 ft. lbs. Material — Carbon Steel Function — For bracing pipe against sway and seismic \t • disturbance. The pipe attachment component of a sway brace sys- 3 tem: Fig. 1000 is used in conjunction with a TOLCO 1 1 Fig. 900 Series Fitting and joined together with bracing pipe per ji ' NFPA 13*or TOLCO OSHPD Approved Seismic Manual, j � forming a complete sway brace assembly. /' I f Features — Field adjustable, making critical pre-engineering of = j f bracing pipe unnecessary. Unique design requires no threading of y,f i bracing pipe. Can be used as a component of a 4-way riser brace. 7 /, Can be used as longitudinal brace with Fig. 907. Comes assembled K. ,�< - and individually packaged with illustrated installation instructions - `.-Al/:' — sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been _ achieved. Installation — The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be Maximum Design Load combined with the "bracing pipe" and TOLCO structural attach- 1" thru 4" pipe size — 2015 lbs. ment component, Fig. 980, 910 or 909 to form a complete bracing 6" size — 1265 lbs. assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. FM Approved Design Loads" Brace pipe can be installed on top or bottom of pipe to be braced. 1" -21/2" - 600 lbs. Tighten hex nuts until leaf spring is flat. It is recommended that the 3" -4" - 700 lbs. brace angle be adjusted before hex nuts are fully tightened. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note — Position Fast Clamp and tighten two hex nuts / until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish — Plain . ) \ Note — Available in Electro-Galvanized and HDG finish or Stainless i. _.- , ` f Steel materials. \ Order By — Order first by pipe size to be braced,followed by pipe ti' ' size used for bracing, figure number and finish. Lateral Brace 4. TOLCO®brand bracing components are desgined to be compatible ONLY with other TOLCO®brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO®brand bracing components, in the instance that such TOLCO®brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH. 951.737,5599•FAX, 951.737.0330 CUSTOMER SERVICE•800 786 5266El www.tolco.com TOLCO" Seismic Bracing Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment ®TOLC.O- c UL us Size Range: 2" (50mm)through 8" (200mm)IPS. usnD Material: Steel Set Screw&Hardware �'� Function: For bracing pipe against sway and seismic disturbance. Included .7I/ --.0.0/0,‘ Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL)21/2" (65mm)through 8" (200mm)pipe.Approved by Factory Itki.Mutual Engineering(FM),2" (50mm)through 8" (200mm)pipe. Installation Instructions: Fig.4L is the "braced pipe"attachment component of a longitudinal sway brace assembly. It is intended to beA combined with the"bracing pipe"and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or ` OSHPD guidelines should be followed. tin ILI/ c - To Install: Place the Fig.4L over the pipe to be braced and tighten v bolts.Then engage"bracing pipe" into jaw opening and tighten set screw c m until head snaps off.Jaw attachment can pivot for adjustment to proper '° brace angle. �i m , Finish: Plain.Contact B-Line for alternative finishes and materials. ! Order By: Figure number,pipe size and finish. irr. •t " Y Alk ` Ey Longitudinal 4-Way Riser Brace ,�� Brace (plan view) i ; I. .1_ .1 Pipe Max.Rec.Load *Max.Design Load Approx. Part Size A C D Bolt Size (cULuc) (FM) Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kg) 4L:'" ® (50) 53/8" (136.5) 21/16" (52.4) 21/16" (52.4) 1/2"-13 2015 (8.96) -- (--) 247 (112.0) rth 21/2 67!16" (163.5) 21/2 CUM (69.8) 11120 2015 ;, (8.96) 3000 (13.34) 253 mg .. ® (80) 7 (177.8) 23/4 (69.8) 31/16" (77.8) 1/2"-13 2015 (8.96) 1550 (6.89) 268 (121.5) (100): 81/2" (215.9) 33/8" En 311/16" (93.7) 1/2"-13 2015 (8.96) 1550 (6.89 348 b® (125) 93/4" 7/8" 3 1 ) (172.3) (247.6) 3 (98.4) 4/a (111.1) /2 13 2015 (8.96) 1450 (6.45) 380 (172.3) ,. 6" (150} 111/2" (292.1) 5" (127.0) 5118" (130.2) ..112" 13 2015 (8.96) 1450 ` 640 ' ;; 8" (200) 131/4" 5 �� (290.3) (336.5) 5/8 (142.8) 55/8" (142.9) 1/2"-13 2015 (8.96) 1450 (6.45) 728 (330.2) Pipe Max.Rec.Load *Max.Design Load(FM) Part Size (cULuc) 30-44° 45-59° 60°-74° 75°-90° *The loads listed are axial loads on the No. in. (mm) lbs./(kN) lbs./(kN) lbs./(kN lbsJ(kN) lbs•!(kN) brace.The horizontal load capacity, H,of ® (50) 2015(8.96) -- -- -- -- the brace is: H=F x sin?,where?the 21/2" (65) 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) installation angle measured from the advertical. FM approved when used with 1", ® (80) 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) 11/4", 11/2"or 2"Sch.40 brace pipe. G (100) 2015(8.96); 530(2.36), 730(3.25) 890(3.96) 990(4.40) ® (125) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 4L Y,k 6' (150) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) CEA 8" (200) 2015(8.96) 490(2.18) 680(3.02) 830(3.69) 930(4.13) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that,in addition to the other exclusions from B-Line's warranty,Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 170 B-Line by E:T*N TOLCO- Seismic Bracing FiSizye Range:LOngStudn Longitudinal oo Sway Brace Attachment through ( ) ®TOLCO- .o..o„m Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Approved by Factory Mutual Engineering(FM),1"(25mm)through 12"(300mm)pipe. 0, Installation Instructions: Fig.4LA can be used as the system attachment gm • component of a longitudinal or lateral brace assembly.It is intended to be .4,.- D combined with the"bracing member"and TOLCO transitional attachment 4 A and structural attachment to form a complete bracing assembly.For fire .1 "r' sprinkler applications NFPA 13 guidelines should be followed. 2°° C ' -' i To Install: Place the Fig.4LA pipe clamp component over the pipe to be i "' '' 4 m braced and tighten down the break-off nuts until the hex head portion breaks , ' IX y 4] off to verify correct installation torque.Next engage brace member(pipe or 41A-1 thru 4LA-4 41 m strut) with jaw component and tighten break-off head bolt until the hex head breaks off to verify correct installation torque.Pivot jaw ,t for correct angle and attach to structure using TOLCO brand transitional Pattachment and structural attachment. Finish: Plain or Electro-Galvanized.Contact B-Line iet ii Y4= for alternative finishes and materials. Order By: Figure number,pipe size and finish. .' A s : -.-,*:',74;,:":%:::<- 4 C 4LA-5 thru 41A-12 Pipe Approx. Part Size A C D Bolt Size Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 'J LA-1 1" (25) 319/32" (91.2) 15/16" (33.5) 15/16" (33.5) 3/8"-16 119 (54.0) 11/4" M® 329/32" '9.3) 13/8" IMIIINZIEM 3/8"-16 ' ® 55.8 IliA:a 11/2" (40) 45/32" (105.7) 11/2" (38.5) 11/2" (38.5) 3/8"-16 127 (57.6) -:T-:7 in' " 2" (50) BEIM 21/32" (51,9) 21/16"; c 3/8"-16 ; 142 (64.4) 21/2" (65) 527/32" (148.7) 25/16" (58.5) 25/16" (58.5) 3/8"-16 173 (78.5) if;Lill NEE (80) 61/2" (164.9) um (66.6) 25/8" (66.6) 3/8"-16 187> (84.8) 41.A-3,_ 31/2' (90) 7.407" (188.1) 27/8" (73.1) 27/8" (73.1) 3/8"-16 198 (89.8) 4" (100) 713/32" (190.8) MI (79.5) 31/8" (79.5) 3/8"-16 209 (94.8) 5" (125) 83/4" (222.3) 35/8' (92.1) 35/8" (92.1) 1/2"-13 298 (135.2) 4LA„'.3 x 6 (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.9) Eisumium (236.3) 8" (200) 1213/16" (325.5) 59/16" (143.7) 521/32" (143.7) 1/2"-13 629 (285.3) -10 10" (250)` 161/2" (419.1) `71/4" Eamminiam 1/2"-13 1320` (598.7) 4 A-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"-13 1496 (678.6) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly.B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that,in addition to the other exclusions from B-Line's warranty,Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line bvETN 171 Pipe Hangers&Supports TOLCOTM Seismic Bracing Fig.4LA- Longitudinal"In-Line"Sway Brace Attachment cont. ®TOLCO` i5r "0 / Longitudinal Lateral 0 Brace V Brace d I a, c m 0 Longitudinal Loads FM Max.Design Load Max.Rec. m Part Pipe Size 30°44° 450-59° 600-74° 750-90° Load : ` No. in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) _' 1 .; 1" (25) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) mai ma® 680 (3.02)` 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 Ems riim 11/2" (40) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 141,A-2"j 7 (50) 680 (3.02) 860 Mill 1030 E 1150 (5.11) 1000 IMII KEEM 21/2" (65) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 3" (80) 680 (3.02) 970 EMI 190 (5.29) 1320 (5.87) 1000 (4.45) KM 31/2" (90) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) ElaiLi 4" 100 680 3.02 970 `IIMM 1190 5.29 1320 IrMI 1000 OM nal 5" (125) - - - a - - - - 1600 (7.11) LA-6:, 6" (150) s' ` 1620 (7.20) 2,260 (10.05) 2010 (8.94)' 2220 (9.87), 1600 (711) 8" (200) 1620 (7.20) 1,660 (7.38) 1570 (6.98) 1740 (7.74) 2015 (8.96) /4::-.-. 0 10" (250) 1620 (7.20) 1,660 (7.38) 1570 (6.98) 1740 (7.74) 2765 (12.30) LA-12,.,E 12" (300) 1620 (7.20) 1,660 (738) 1570 (6.98) 1740 (7.74) - - Lateral Loads FM Max.Design Load Max.Rec. Part Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Load No. in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN} s., FZErill 1" (25) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) Ei LA=11!, '11/4" (32) 680 "(102) 970'' (431) 1190 (5.29) 1320 IIIIM 1000 (4.45) 44LA- 11/2" (40) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (445) rntru® (50) 680 (3.02) 970 M 1190 (5.29) 1320 MI 1000 (4.45) ma 21/2" (65) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4,,:i4:3 ® 80 680 3.02) 970 N(J7 1190 529 1320 5.8 1000 II • )1' 31/2" (90) 680 (3.02) 970 (431) 1190 (5.29) 1320 (5.87) 1000 (4.45) -4•',> 4" 100 680 3.02 970 raill 1190 129 1320 5.8 1000 EMII * 76 • 5" (125) - - - - - - - 1600 (7.11) 6" (150) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) 1600 (7.11) 8" (200) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) 2015 (8.96) it - 10' (250) 1620 (7 20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) 2765 (12.30) 2;:'i 12" (300) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) - - Eaton's B-Une Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that,in addition to the other exclusions from B-Line's warranty,Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports B-Line 172 by E:T•N Seismic Bracing Fig. 909- No-Thread Swivel Sway Brace Attachment I®TOLcO Size Range: 1"(25mm)bracing pipe. For brace pipe sizes larger than g US 1"(25mm), use Fig. 980.Available with holes for 3i8"-16 thru 3/4"-10 fastener UMW attachment. Material: Steel, hardened cone point set bolt c Function: The structural component of a sway and seismic bracing system. m i Features: This product's design incorporates a concentric attachment 0 opening which is critical to the performance of structural seismic connections. H NFPA 13 indicates clearly that fastener table load values are based only on ' cn concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. of Application Note: Fig. 909 is used in conjunction with the Fig. 1000, , .� Fig. 1001, Fig.4A or Fig.4L or other approved TOLCO attachment to pipe, %• ®• and joined together with bracing pipe. Sway brace assemblies are intended to �' D be installed in accordance with NFPA 13. The required type, number and size ) l of fasteners used for the structure attachment fitting shall be in accordance .....) with NFPA 13. �^ Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada Set Bolt A (cUL). Included B Installation Instructions: Fig. 909 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to Mounting Hardware be combined with the"bracing pipe"and TOLCO"braced pipe"attachment, Is Not Included Fig. 1000, 1001, 4A, or other approved TOLCO attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 909 onto the bracing pipe.Tighten the set bolt - until the head bottoms out on surface.Attachment can pivot for adjustment to proper brace angle. ; Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and - it h materials. Order By: Figure number, fastener attachment size and finish. , . Part Mounting Hole Brace Max.Design Approx. Number D Pipe Size A B Load Wt./100 in. (mm) in. (mm) in. (nm) in. (nm) lbs. (kN) lbs. (kg) 909-1/2* 17/32" (13.5) 1" (25) 6",(152.41 15/8"(41.3) 2015 (8.961 91 (413) 909-5/8 11/16" (17.5) 1" 1251 6" (152.4) 15/8" (41.3) 2015 (8.961 90 (40.8) 909-3/4 _ 13/16" (20.6) 1" (25) 6" (152.4) 15/6",(41.3) 2015 (8.96) 89 ,(40.4) Other hole sizes are available, consult factory. * Standard size. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that,in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 63 by E.T*N Youngstown Tube rr Schedule 40 Sprinkler Pipe Youngstown Tube manufactures Schedule 40 pipe in sizes 1" thru 2"using only high quality domestic steel. This ensures a uniform superior product for threading,roll grooving, welding or plain end uses. Youngstown Tube's schedule 40 pipe is produced under ASTM A135/A795 Type E, Grade A,NH standards. Every piece is Eddy-Current tested and conforms to internal SPC testing and recording. Youngstown Tube Schedule 40 steel sprinkler pipe is coated with a black enamel coating, continuous color coded red stencil, and stored indoors ready for immediate shipment. Approvals o UL Listed o CUL Listed o FM Approved Youngstown Tube schedule 40 pipe meets the rigorous testing and certification processes of Underwriters Laboratory and Factory Mutual for steel sprinkler pipe with working pressures of 300 psi or less. It also meets the requirements of NFPA 13 and can be used in wet, dry, deluge and preaction systems. Schedule 40 , Pipe Pipe Nominal Weight per Standard Pieces? Feet Weight per UL OD Wall Foot Length Per per Bundle Threaded Bundle' Bundle CRR 1 1.315 133 1.68 21 61 1,281 2,152 FT-6o— FT- 1.660 .140 2.27 21 1-67-1172-8-1— 2,907 1.00 1 'h 1.900 1-744-79-57 .145 2.72 212,511 1.00 2 2.375 .154 I 3.65 I 21 D-7-77-7-1 2,836 1.00 Youngstown Tube Company 401 Andrews Avenue Youngstown,Ohio 44505 1-866-The-Tube www.youngstowntube.com 7ffiTT2 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 CPVC - COPPER #905 #905 STEEL i OFFSET HANGER 3100 1 1 Y MN 11111. INIMMINM SIZE-SYSTEM PIPE: 3/4"thru 2" O MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- Hanger/Restrainer US 203-EX 4231,EX 2551 PATENT-No.6,648,278. MIMI ■% FUNCTION- Support horizontal piping: CPVC,Copper or Steel. 1.1 Provides listed vertical/horizontal restraint and prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. Hanger/ �� INSTALLATION- Per these instructions Restrainer All Stabilize including NFPA 13, 13R, 13D and CPVC manufacturers instructions. ,"' _ Install on horizontal or vertical mounting surface. I_ Snap over pipe then squeeze strap back allowing pipe to slide freely. w When #905 threads are exposed in wood,install#906 backing nut. FASTENERS-UL Listed per NFPA 13 Qv WOOD- CPVC pipe-#905 screw-no pre-drill. Copper and Steel pipe-#14 SMS or 1/4"xl 1/2"lag screw- no pre-drill. Thru 5/8"gypsum board- 1/4"x 2"lag screw. STEEL-min. 18 GA.-CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw. CONCRETE:Required minimum load each fastener= 5(wt)+2501bs. o 2 4 4 FEATURES .s7- * * 1 1/2"Offset-loose fit allows pipe to slide. • o A *Common center-line for 3/4" and 1". •. •, *Offset edge eliminates abrasion. *AFCON#905 screw included-5/16"hex head. a ORDERING-Part#and pipe size. AFCON#906 backing nut sold separately. `.r Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 11/13 # Pipe Hangers Fig. 200- "Trimline"Adjustable Band Hanger (B-Line Fig. B317ONF) eTDt,f Fig. 200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) t: UL us Fig. 200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" 115mm)thru 8" 1200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. ,- _ Features: .. • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe _ � , •- types and protect CPVC plastic pipe from abrasion. Captured design ``' keeps adjusting nut from separating with hanger. Hanger is easily n - \ B ;' ` installed around pipe. A - I For hanger with non-captured nut order Fig. 200S. r ` • (21/2" (65mm)thru 8" )2oomm)) Spring tension on nut holds it securely in / _ hanger before installation.Adjusting nut is easily removed. x- ,: Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) Fig.no-1/2.no-3/4 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F 1343°C) m; Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts ,w.. 'r. in place of a knurl nut. . . • ' { . Order By: Figure number and pipe size = 1 Designed to meet or exceed requirements of FM DS 2-0. ``` ,. lb. ' Fig.200 • Fig.200C Fig.200F v Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) .4";.-- ' 200-1/? 1/2" (15) ' 3/8-16 31/8 (79.4) 25/8" (667) 11 (5.0) 200-3/4 3/4" 1201 3/8"-16 31/8" (79.4) 21/2" (63.51 11 15.01 ':: 200-1 1" (251 3/a"-16 33/8" (857) 25/8" (667) 12 15.5) 200-11/4 11/4" 1321 3/8"-16 33/4" (94.0) 21/8" (73.0) 13 (5.9) .0: 200-1't 11/2" (40) 3/8"-1637/g (98.4) 27/e" (73.0) 14 (6.4) ',..'"' '',..:.\\ 200-2 2" (501 3/8"-16 41/2" (114.3) 3' (76.31 15 (6.91 ' 200-21/2 21/2" (65) 3(8-16 55/8. (142.9) 41/e (104.7) 27 (123) 200-3 3" 1751 3/8"-16 51/8" 1149.11 4" (101.61 29 (133) Fig.200S 200-3Vz 31/2 (90) 3/8"-16 ' 73/8 (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" 11001 3/9"-16 73/8" (187.31 5" (127.0) 35 116.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (1567) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4' (171.4) 73 (33.4) 200-8 8" •(200) 1/2"-13 131/8"; (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B`Li ne 21 by EIT•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) 83205E - Threaded Rod (right&lefthand threads) rl 111 Size Range: 3/8"-16 thru 3"-4 rod Speedy Length Material: Steel Function: Recommended for wuse as a hanger support in hanger assemblies. n ��lll�ll. d on th en h Rod is thre, h t available with Deft and oright hand threadsh spechfy Fig. 63205E hen ordering.lso �1��0 A Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B Line for alternative finishes and materials. Order By: Part number,rod size,length and finish w .r Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) • " °i8 x'L 3/8" 16 21/2" (63.5) 730 (3.25) 572 (2.54) +06-1/2x'L' " 1/2" 13 21/2 (63.5) 1350 (6.00) 1057,' (4.70} +'. /sx'L` 5B.._i 1 21/2" (63.5) 2160 (9.61) 1692 (7.52) Eki.,...3,4 x'L 3/4"-10 3° (76.2) 3230 2530 (1125}„ B32i °'Lfi 7/e" 9 31/2" (88.9) 4480 (19.93) 3508 (15.60) ,13321'-;91 l' w ` 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) ,B3205-i. 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) �. °" 11/4 7 5° (127.0) 9500 (42.25) 7440 '(33.09) ', +1.", , 2 x'L' 11/2" 6 6" (152.4) 13800 (61.38) 10807 (48.07 '+05-13/4 x' !' 13/4 -5 7 (177.8) 18600 (82.73) 14566 (64.79} +i�:2x'L. 2" 41/2 8" (203.2) 24600 (109.42) 1110450686:657 9625 (87.29) (228.6) 32300117221617797.1370233)})- 25295 (112.51) B32' - 1 x'L': 21/2"-4 1 " (254.0) 39800 (177.03) 31169 (138.64) +(15=23/011-..-123/4 4 :4 11-' (279.4) 49400 (219.73X`£`. 38687 (172.08) w ,,,l1..4 x'L' .,'. 3' 4 12" (304.8) 60100 (267.32) 433781061686679 7066 (209.35) .I t ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99-All Threaded Rod Cut To Length �\\� ,$),0';'')0) �1 1� .,,v,,,,,* Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length y ��>>1�������1111 Material: Steel t -) Maximum Temperature: 750°F(399°C) rpt v o` Finish: Plain.Contact B-Line for alternative finishes and materials. � d Order By: Part number,rod diameter and finish F Part No. Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.90 Per Inch Lbs. {kN) Lbs. (kg) 1%4" i 90-1%4" 20 240 (1.07) 12 (5.44) . 20;; 99-3 le 16 ' 730 (3.24) 29 (13.15} A ' 99.1 x le 13 1350 (6.00) 53 (24.04) >� n".5"*.- 20unit11 2160 (9.60} . 89 (40.37) /4_"X 1 0 x*' 10 3230 (14.37) 123 (55.79) 0 :' ? x leng b 1 9 4480 (19.93) 170 (77.11) ATB _ix 2b '' �x "�'ili' 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised 4/28/2014 Line by E;T•N VERTICAL MOUNT m. Y SAMMYS® for Wood Not less than 2°nominal width Wood Flowing Product } (1-1/21 4 •No pre-drilling reque Not less than •Quick to installFeatures using irthed. Sammy a°nominal v. Nut Driver with an 18V cordless thickness(2-1/21 (depth or side wood Joist drill/driver. ofvedbalmember) 4 m.._ u - k- - - •Saves time from traditional Double Sheebocmethods. For vertical use- Ceiling install in center of:ower face. )' •Reduces installation cost. Minimum 2'emoedment into base ,• material for NFPA 13 compliance Composite!Truss K Consult truss manufacturer for •Made in the U.S.A. .€ recommended installation point, -'' 'Pre-drilling maybe required for GST 25-380.Tool available on page 10. Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number descriptions Pullout(lbs) sj load(lbs) Qty Qty (t'; .,a''''''''''''' 8?295- 100 114 x 1,u t r 3, "'� iii,-1:;;;;:.7.. 25 125 1/4" 8003957 GST 200 1/4 x 2" ,1�76^0^ (Fir) 25 125 •14" ` :tt wd'• _t.� 00 1/4x3. 1,1„t50-.-,-,,_to: a 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564(3/4"Py) 25 125 u .�,• „17, n fir, - r ”`3/8 i'4 t t 9 n GST 10 4 x 1 4 210'0 148 SB}:14. 300 v �25 25 v' 3/8" 8008957 GST 20 114 x 2" 1760(Fir) 850 1475 25 125 • e` 318 . t 925 GST 20-SS 114x2' �t 50 25 X25 ; 3l8 8009925 GST 25-380 3/8 x 2 1/2 2113(Fir) 1500 25 125 i•© 3/8.7x 00 t° 7 GST 30. 1/4x3 t.t{E 3 00 : r-.'25 `R 5 ' #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 V, 318 8011925 GS`TA0' x 2180(Fkj'• .s -? 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 _ 1 , 8013925 GST 2.f, X 2iiiii 1780 1'1 l2,. 8014925 GST 2.5-380 3/8 x 2-1/2" 2113(Fir) 25 125 1 . 1/2" x• 8015925 ,a , GST 3; % .,=2275 }, 25 12 1/2" 8016925 GST 4 1/4;4"4" " 2180(Fir) 25 125 sx 1 _ 8.;,$01742 E 1 J' ' yti.t dk " = 25 125 . #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Heads for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'/"x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout(lbs) Load(lbs) Load(lbs) Thickness Qty Qty ,a ink•:k= 81 GST 20 tl 2' , 2 r}µ, s. i rr. tt z 75 'r 25 125 125 .' 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installaton each time.When the faceof the driver comes into part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Instarlla0on is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information.visit www.sammysuperscrew.com 4 a tiS