PFI2016-00128 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
s COMMUNITY DEVELOPMENT Permit#: PF12016-00128
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 06/21/2016
Parcel: SEG 1145, 1217
Jurisdiction: Tigard
Site address: 12800 SW ASH
Subdivision: Lot:
Project: Ash Ave PFI
Project Description: Ash Ave Apartments relocate 3 OH spans for new development
Owner: FEES
Description Date Amount
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
LINDA OTT
10800 SW AVERY ST
TUALATIN, OR 97062
PHONE: 503-612-6093
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant Not Present
Signature:
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12016-00128
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc.,shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit. Ken Fisher 503-816-6146 or Kenny@tigard-or.gov
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2) persons who have
authority to resolve problems,take corrective action and, in general, will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard JUN 14 2016
41 PUBLIC WORKS — ENGINEERING PGE WORK ORDER# M1853526
TIGARD
Public Facility Improvement (PFI) Imf"GINEERING
DESCRIPTION OF WORK(in the right-of-way) REQUIRED SUBMITTAL
Check one: R Utilities ❑ Sidewalk/driveway approach ❑ Street improvements ELEMENTS
Detailed description: Ash Ave Apartments - relocate 3 OH ❑ Minor work in right-of-way
spans for new development- DDR (sidewalk repair,curb cut,street
s
P P opening,etc.)requires:
•Application form,completed
and signed
•Submit one(1)copy of scaled sketch
Property address/location(s): 12800 SW Ash Ave Tigard OR of the proposed work to be done
•Submit one(1)copy of traffic
97223 SCO 5 / 1 Z r 7 control plan
—OR—
Linda Ott Portland General Electric ❑ Substantial project work requires
Applicant's name: above items and professional
Address: 10800 SW Avery ST engineered plans for:
City/state: Tualatin OR Zip: 97062 •Street widening
•Subdivision infrastructure
Phone: 503-612-6093 Email: linda.ott@pgn.com •Main utility line extension:
Storm Drain,Sanitary—Tigard
Water—Tigard Water Service
Contractors name: na Area(includes Durham,King City
CCB Expiration: and a portion of unincorporated
Washington County)
Address:
City/state: Zip: DELIVER APPLICATION TO:
City of Tigard
Phone: Email: Planning/Engineering
13125 SW Hall Blvd.
Engineer's name:
Gordon Hill Portland General Electric Tigard,OR 97223
Address: 10800 SW Avery ST Applications for"minor work in right-of-way"
only may be emailed to:
City/state: Tualatin Or Zip: 97062 9wnermitsntigard-or.gov
Phone: 503-672-5477 Email: Gordon.Hill@pgn.com
Case No.: PF-T 1.01 L-
G 12
Estimated value of work (within the public right-of-way): $
Application submittal fee:
Is work related to a LAND-USE DECISION? ❑ Yes ❑ No Application accepted:
If so,please specify (MLP, SDR,SUB, etc.) case #: By: ^1 f) Date:
Is work related to a BUILDING PERMIT? ❑ Yes ❑ No Application reviewed:
If so,please specify(BUILDING PERMIT)case#: By: K 1>ti Date: L "per 1 w
Applicant notified:
`41
75 I's gw,44t-4 'lr 4 am+ N-,u By: LS Date:
e L9ZX441AU-A t� /a,PA2�OK e-.�sr S.
I:\CURPLN\Mastem\land Use Applkatlons Rev.07/16/2014
A s
City
Qof Tigard • 131125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 4
q 0
APPLICANTS
NOTE: Person specified as"Applicant" shall be designated"Permittee"and shall provide financial assurance for work.
*When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written
authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written
authorization with this application.
BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT:
• The above request does not violate any deed restrictions that may be attached to or imposed upon the subject propcLv.
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
SIGNATURES of each owner of the subject property required.
Applicant/Authorized Agent's signature Print name Date
Owner's signature Print name Date
Owners signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4
11oan 17 FJI 3032 OVERHEAD LEGEND
DAKOTA
=REMOVE FACILITIES=INSTALL FACILITIES
TIGAIID REPLACE AND RELOCATE 25'NORTH =INSTALL ADDITIONAL FACILITIES/MODIFY FACILITIES
# AND i7'EAST
y/ALTIUI a• ,/
-------- INSTAL 3-#2 R ON PRIMARY d 1-#2M2 ACSR LOW
NEUTRAL
Ss
--------
10 SITE '�$ 1-#2AA R#2 ACSR ON (MARY d
LOW NEUTRAL
MC DONALD WJE TRANSFER STREET LIGHT -------- INSTALL 1-411 AL-OX OH SECONDARY
GAARDE 9N P� S -------- INSTALL 1-k2 AL-TX ON SECONDARY
� "N"A
�p � � � TRANSFER EXISTING SERVICE
igard BG Q 16'L -------- R STLLI 3 Px MfM M PRI MRY IN ."P C CONDUIT
'9,L A3 31,106k PRONOFD a INSTALLED er CIASTOMER
S9 ------ INSTALL t-AD A(-TX SECONDARY IN I-3"PVC CONDUIT
vlclNm MAP
dJ IROVIDED a INS—C.a'/CUSTOMER
`rT G79 pRl 15,391# G19 NEUT/SEC 10.122# -------- P—t &INST SECONDARY IN St PVC CDNDUrt
Hb� PROMDED a INSIALIED BY CUSTOMER
r R3D M
SECDN r
D /ROVIDFD a INSTMlfOi RY CUSTOMER
REPLACE 55199
/ - �• 10 POLES
\ POLE CLASS(1,2,3.4,HI,112,5)
/ .'00027/
WITH ]200V 1'`'T/ w.lE HEIGHT(FEET)
PL03032 50-3 RGE To EXRDS120240V
j - ROLE AND
AND FXI NFW 4'RL'C 1 3W
FROM M TO N1CtOrN.wMs Mu wRi
Melt 03032 EW FRAMING iRAN5MIS510N 6 85111 pt (SECS BELOW)
-2003-50 snxE ToO FYIS,ING 4'coNDun 73.13.1 KW DEMAND
n.IRf>e INSTALL 4'POLE CONDUIT UNIT Dl O nI Ei aml
WITH 12'BRACKETS,3_142 GO F40T DB
ro'ME W 789 LIGHTNING ARRESTER PHI scL.DE'ratl;
INSTALL 3'PVC CONDUIT yc
C D83 l Drs rcullloNR,N.KKxa wMS MU aa3
G4 sec 2000k.� � �5� V ��. 4'• �
PS' B 0 5519 ,PF CONDUIT ANCHORS g
p., Q (LEAD 1 O g A
CONWR! R
50 29811 FRONTIER TO ON LB3 j e n
1987 5 '119' AND SELL TO PGE Ar q AS u AR
VT 00084 TOP TO COMUST
/ \ 3-142 PGE TO PULL
F40T PGE 7o OWN
PL03032 GUYING
- 0932 1
4 -2 AL-DB S § S r
'•� ,,1 A 25 94532 9329
INSrAu 120'#2 AL-TX03053 B 25 94594 r- x Gurs cx cs ce cn , x x3
1955-40 25 94589
�I r TO CONST TEMP WE TO EXPOSE x EXISTING w u REPLACE AND RELOCATE 25'SOUTH 3 GUYS G3 G6 G9 x b
µ
3-4/0 AL XLP ti.4 N NEURAL AND 17'EAST,WITH:
i 1-2 Cu BBp �ExrEND Nfw-E
AND TAEa'30ry c WR CHECKLIST
207' B 25 13195 SEIMTO INrO v ULT �x D83 To NORTH 08 To Sour. REM YES COMMENT
HDILOIGGH Y
V LOON Y
M Dp X
i PO 07118 94532 94594 94589 Tee neIKR
0 ABC 225 859 25 25 zs
C ABC 225 859
«arts
07 e
...\ 3-U2 GO SEI,FMFM X
F6 T F6 T F6 T nPGGING
]2.V RLERW x IAf-ILLf EMp/u
&� PI-3033 INSTALL w osu x Ton
PL-3034 25 A9 25 Bgr 25 c9 12020BV
REPLACE AND RELOCATE 114'SOUTH 3111 DEMAND 4W NOnni Y CN IX NARD
REPLACE AND RELOCATE 7'NORTH AND I5'EAST 1PH DEMAND 53.3K auric RAM
AND 14'EAST
18T O D1 uc O R AR
o3o`.M
AI 13,795# a a 9ENDOwN
1998-43 P A,317,'1106, G79 PR115,,H, GI9 NEUT 10,122# [USiOND
1-142
F25T 1' G16
PL03034 a PRI 5,584# Glb NEUT 4,440k REPLACE 13193 FRONTIER TO DN CONTACT RYM
15 TOP TO COMCAST
B i S 48269 PGE TO PULL M C.
1 PGE TO OWN o.n iNE
� REPLACE 48269 WITH ]200`/
'10 • 13 15 B 120240V
PD 9554 1PH,3W
7 KW DEMAND
WITH 720DV / THIN[ ASBUILTVERIFICATION d NESC VIOLATIONS CORRECTED
BAPBTY Me d«vm M o YMe P2Renn FIELD Conn,�PP.
is B 120240V I--.:-
10.4
--.: paM:
VT 105 ?PH,3W FRONTIER TO ON 10 KW DEMAND AND SELL TO PGE PIRSTI
General FDrcmon: pule;
TO v TO COMCAST S"neuro on uimd for held conomc8on chon es.
A 100 5090 INSTALL 2'POLE CONDUIT UNIT PGE TO PULL
PGE TO EXPOSE IXLSnNG b AL-ry
WITH 12'BRACKETS,1-612 CO F25T PGE TO OWN SDPI ENG REVIEW: ASBUILT BY DESIGNER
r_3'PVC CONDUIT I LIGHTNING ARRESTER COMMIT SERVICE COORDINATOR wiE,62A6 1':60' 'KCAL'10]0001 �'1000004545 "1O-MI853376
AND fxrFNo NEw 3•Pec INSTAL 3-PVC CONDUIT scuE A
FROM M 10 NFw POET rw ASH AVENUE APTS-RELOCATE 3 OH SPANS FOR NEW DEVELOPMENT-DD
PGE TO REMOVE EXISTING 40TX, r ' /` OaCui SITE
pNUP(E IXRnNG 3"PVC 10
D REINSTALL t0 Rl-T% LGE TO IXPOSF EXISTING Px K-DB 1 Y' S0}1]63/50 OR SDSIN�3.f(SNIMI TIGAIPD-13337 18+24
BEMEEN OLD AND NEW POLES .� CONWR CALL BO BEFORE YOU DIG PGE
LDu,IDN
PGE TO RE-DIRECT UP NEW PORE TRIVIIO I RB00 SW ASH AVE,TIGAFD
IR
SIIICE AS NEEDED 3.. OREGON UW RFOlRRES YOU TO TOLLOW RULES ADOIIED
CONDUIT RY TIE ORfCAN UIRI,Y NOnilGibN CENTER. Rm
THOSE MES ARE SET ROI,RN IN OAR P33-0m-OOro ASH AVENUE APTS-RELOCATE 3 ON SPANS FOR NEW DEVELOPMENT-W
FRONTIER TO ON x FroFo,ro U ry wrtt OF cm22A'
TOP TO COMCAST NOTRIGTKN.CEMN ADANMTMnON®(503-x3x-MB7) is WASH CO CIF22
PGE TO PULL n UfIUi1'LOCATES CALL TILE ORfCAN P2-rc ISO' wAwN Rr
PGE TO OWN onRGMIN CFNRA Bn AT(EAST NMR,BM's�1�' ...n�uv.o.na V"- HILL 612-54]] DUMRPU IMF
PRIOR TO EXG AiION. CaB BRIBER/RRdIi O PORTLAND GENERAL ELFC,RIC CO.-ALL RIGNR RESERVED
Page 78 2011 Edition
Work on Shoulder Diagram 210
Diagram 210 covers stationary work with work or parked equipment on the
shoulder. This diagram does not cover work on a freeway shoulder. See
Diagram 710 for Freeway Shoulder work.
1. Vehicles should be parked as far off the roadway as practical.
2. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
3. For added visibility,truck-mounted arrow boards or PCMS in caution
mode may be used.
4. Arrow panels in caution mode are recommended for work on roads
with posted speeds of 45 mph or greater and high traffic volumes,
greater than 2000 average daily traffic(ADT).
5. Requirements for signing and devices are shown in Table 5-2, below.
Table 5-2: Device and Signage Guidelines
Proximity to Edge of Traveled Way
More than 15 feet
or behind Barrier or Less than 15 feet
Guardrail'
One advance warning sign is
Advance warning required and two signs are
Work in Place signs, devices, and recommended.
More than 1 Hour flashing warning Cone taper is required. Cones
lights are optional. along the edge of traveled way
are optional.
Work in Place Advance warning signs and devices are optional.
Less than 1 Hour
Sign Spacing and Buffer Lengths(feet)
Posted S acin Between Signs Buffer
Speed A B C Space
20 50
25 100 100 100 75
30 100
4a 350 350 350 125
150
45 180
50 500 500 500 210
55 250
Chapter 5 December 2011
2011 Edition Page 79
Work on Shoulder Diagram 210
11
(Optional)
•
Protection Vehicle
• w/TMA(both Optional)
See Chapter 4
•
•
Buffer
•
•
•
U3
•
•
A
ROAD SHOULDER
WORK OR WORK
AHEAD AHEAD
Initial Warning Sign
1 t *Use as appropriate-see Table 5-2
December 2011 Chapter 5