Report (7) tt 400
/0F3 Sw e,/*Cbf
• ?� Diioin�n4i��°411u�Q��1 ( ° ;
September 28, 2005
CITY OF TIGARD
Canterbury Place LLC OREGON
Dana Hunt
109E 13th St.
Vancouver, WA 98660
RE: TWO STORY 3-PLEX CONDOMINIUM —BUILDING PLAN VIEW-H,G1,H
Tenant Name: Canterbury Crest Occupancy Type: Rt
Construction Type: V-N, Sprinklered Stories: 2
Building Permit: See Below Area: 5259 Sq. Ft.
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire &Rescue Ordinance 99-01 (TVFR99-01) 1999
edition. The submitted plans are approved. The following permits are approved for
construction subject to the following conditions.
Building- 4 10765 Canterbury Lane Permit Number BUP2005-00282
CONDITIONS
1. Special inspection is required for Concrete and reinforcement placement. The special
inspection agency shall furnish inspection reports to the Engineer of Record, CT
Engineering, the General contractor, and the City of Tigard Building Division(attn.
Hap Watkins). All discrepancies shall be brought to the attention of the general
contractor for correction. The special inspector shall submit a final signed report stating
whether the work requiring special inspection was, to the best of the inspector's
knowledge, is in conformance with the approved plans and specifications and the
applicable workmanship provisions of the code 1701.3 OSSC
2. The City of Tigard,Building Division, is requiring Structural Observations per section
1709 Oregon Structural Specialty Code (OSSC). The owner shall employ a registered
design professional to perform structural observations as defined in Section 1702, OS SC.
The structural observations shall take place after the framing of each floor level
prior to the installation of floor joist or roof trusses above the structural framing.
Deficiencies shall be reported in writing to the owner and to the City of Tigard, Building
Division, attention Hap Watkins. FYI The structural observations do not waive the
framing inspection required by code.
2. Shearwall Sheathing and Gypsum Sheathing shall be attached and inspected in stairwells
prior to the construction of stairs or landings.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639-4171 TDD (503) 684-2772
t
3. Safety glazing including but not limited to: the following locations: Each unit of
glazing shall be permanently identified by the manufacturer. Sec. 2406. Some of these
locations are as follows:
a. Glazing in ingress and means of egress doors.
b. Glazing in storm doors.
c. Glazing in an individual fixed or operable panel adjacent to a door where the
nearest vertical edge is within a 24" arc of the door in a closed position and
whose bottom edge is less than 60" above the floor or walking surface except
when there is an intervening wall or other permanent barrier between the door and
the glazing.
4. Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc,
will be charged a deferred submittal fee based on the valuation of the portion of the work
being deferred. The minimum fee shall be $200.00. Deferred items;
• Fire Sprinklers
• Truss Design
• Fire-Stopping Details •
American with Disabilities Act(ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the structure. The City of Tigard reviews the plans and inspects the structure
only for compliance with Chapter 11 of the OSSC which may not include all of the
requirements of the ADA.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall
be maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the
Building Official has issued a certificate of occupancy 109.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully,
G i �
Val Henzel,
Senior Plans Examiner