Correspondence (4) Sherman Engineering, Inc. (503) 230-887& Ph 4 I Q NW Kearney#517, Portlan , OR 97209 (503) 22&-4745 fax MEMORP�NDUM /14 S7-'dC)CP " CO.,)-(Pi c13 c-2 S& Co✓'- I S7.` TO: Mr. Peter Magaro, Architect l 3s )- 10570 SW Citation Drive Beaverton, OR 97008 "/ 3(a 6 CiZ , ---L.--; DATE: June 13, 2007 / q l c FROM: Don P Sherman, PE Principal RE: Cedar Ridge plans Hillsboro, Oregon NOTE: This memo is to inform you of our recommendations for a clarification and a change to the original design. On our design we only show one holdown in corners with abutting shear walls because the design forces are required in one direction at a time and one holdown may work for both directions. Make a note that the larger of the two holdowns must be used. Also we understand a STHD14 holdown has been misplaced. We recommend using a HTT22 in a epoxy setting per our detail Rl. If you have any questions please give me a call. ,czt‘,.4:e.M Gil cat 4.;".iic N s N\ O., • i ......„..)8 CG. Dean Grey @ Comcast.net ��;11i.Fel :gi Fi le-Magaro06l 307.doc