Loading...
Report (24) 445 /5 00 6(.4 Ids-) ) SQ A HUTITG S3 DESIGN BUILD-ASHBURY 1-6-15 ■ 8:27am :C F 3:^M fr"{ffiti 1 CS Beam 4.11.10.7 kmBeamEngine 4.11.10.7 Materials Database 1494. NO SJAIU D I�ll�)� Member Data Q2� ' 11 d ,��� Description: Member Type: Joist Application: Floor Top Lateral Bracing: Continuous giOE 0 C &Iv Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/I Live Load: 40 PSF Deflection Criteria: L/600 live, L/360 total U3A1,303b Dead Load: 15 PSF Deck Connection: Glued &Nailed Filename: Beam1 Joist Design Includes CCMC Vibration Check Subfloor.23/32"OSB Ceiling: 1/2"gypsum Blocking:(See Requirements Below) / 16 0 0 9 1600 �/ Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 2.000" 1.500" 580# -- 2 16' 0.000" Wall DFL Plate(625psi) 2.000" 1.500" 580# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to canyi ng members Live Dead 1 422#(3160) 158#(119p1f) • 2 422#(316p1f) 158#(119plf) Design spans 15' 9.750" t Product: 11 7/8" LPI-18 16.0" O.C. PASSES DESIGN CHECKS Blocking:(None) Design assumes continuous lateral bracing along the top chord. No lateral bracing required along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2292.'# 3100.'# 73% 8' Total Load D+L Shear 580.# 1225.# 47% 0' Total Load D+L End Reaction 580.# 930.# 62% 0' Total Load D+L TL Deflection 0.3760" 0.5271" L/504 8' Total Load D+L LL Deflection 0.2734" 0.3162" L/693 8' Total Load L Vibration 0.0307" 0.0413" 74% Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% 1/1 All product names are trademarks of their respective owners Huttig Building Products-APH This calc conforms to ORS2005, Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. NDS2001 and 20050RSC ' "Passing is defined as when the member,floor joist,beam or girder shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design must be reviewed bya qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturers specifications.