Report (19) 64e6Afacr -00/ 73611 Sw' GJaSA , 1 1 RECEIVE"il Structural Calculations for: MAY 2 3 2015 ` 'V O.F,TIGARD Blue Nile Jewelry BUILDINGDIV DIVISION Washington Sq Mall Portland OR By: Alpesh Chavda, P.E. r; �t PRopo O. 'GIN4 R a im 828811 +, t GON .4ti�A�'1 t'12 20$ 1 !EXPIRES: nift4c.‘ I 2 Calculation modules: 1. Storefront soffit and tenant bulkhead support Design code and loading Design based on Oregon Structural Specialty Code - 2014 Dead loads: 10 PSF for tenant bulkhead framing. Live loads: 10 PSF for soffit horizontal framing. Wind loads: 5 PSF on storefront vertical faces (internal pressure Seismic loads based on the following parameters: USES-Provided Output Ss = 0,983 g SMS = 1.088 g Sas = 0.725 g SI = 0.422 g 5M1 = 0.666 g SDI = 0.444 g ap 1.0 (for storefront soffit/ceiling) Rp 2.5 (for storefront e ont soffit/ceiling) Ip 1.0 Component seismic force: 0.4apSos WI, l P Pp h 1l, Wp component weight z/h 1/2 (attachment to 2nd floor framing structure Fp = 0.23 Wp (storefront framing) Fpmin = 0.21 Wp (does not govern) Seismic weight = 10 PSF Fp = 2.3 PSF => Wind governs Storefront Framing 3 Horizontal soffit framing at 1.44' 0.C: Member span = 4' (maximum) Member UDL = (5+10)(1.33') = 20 PLF Use 3625162-43 Allowable span = 10'-4" OK Project 'Horizontal joist at soffit Section 1R2.. 15162 ,,,1717--- J Single NASPEC Fy Punched I Method I Wt. Loads and Factors Multiplier for Strength Dead Load 15 psi 1.0 Live Load 10 _7.1 PO 11.0 _J Deflection Wind Load 15 psi 11_0 J 11.0 27.1 Deflection Limit Li 1360 zi Number of Spans Web Crippling and Shear Parameters r: One Span r Require Web Stiffeners at Supports 7 Two Equal ( Two or More Equal E Consider Punched Near Supports ? —Torsion Inputs RI Include Torsion Lever Arm for Torsion to: 1Web Center 211 Allowable Ceiling Spans Spacing of Braces(in o.c.) Joist Spacing , (in o.c.) NONE j MID Pt ..1 ITHIRD Pt 112 Lr 16 zi 124 Boxed beams at front and back of soffit (2) studs boxed with (2) tracks. Consider studs for vertical loads and tracks for horizontal Beam span for vertical loads = 17' • 4 Vertical reaction from soffit framing = 30 plf Vertical load from tenant bulkhead = (10)(4) = 40 plf (front beam only) Total vertical load = 70 PLF Use (2) 10005162-68 studs in boxed beam Allowable UDL for 26' span = 201 PLF (OK) Beam span for horizontal loads = 4' (distance between diagonal braces) Wind reaction at boxed beam = (5)(16'/2)(4'/2) = 80 PLF (seismic governs) Use (2) 362T125-68 tracks in boxed beam Allowable UDL in 4' span = 738 PLF (OK) Boxed post Axial load in boxed post = (70)(17'/2) = 595 Lbs Horizontal loads transferred directly to structure via braces and does not end in posts. Post height = 19' Use (2)3625162-43 (neglect contribution of tracks in boxed post) Allowable axial load = 2993 Lbs OK End storefront framing module