Loading...
Permit (84) CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT 1111 Permit#: FPS2016-00106 COMMUNITY DEVELOPMENT Date Issued: 06/23/2016 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S1260000300 Jurisdiction: Tigard Site address: 9647 SW WASHINGTON SQUARE RD FC09 Project: Charley's Philly Steaks Subdivision: None Lot: None Project Description: Alter(9)sprinkler heads for TI. Contractor: WYATT FIRE PROTECTION INC. Owner: PPR WASHINGTON SQUARE LLC 9095 SW BURNHAM PO BOX 847 TIGARD,OR 97223 CARLSBAD, CA 92018 PHONE: 503-684-2928 PHONE: FAX: 503-684-9657 FEES Description Date Amount Specifics: Permit Fee-COM 06/23/2016 $69.92 12%State Surcharge-Building 06/23/2016 $8.39 Type of Use: Plan Review-Fire Life Safety-COM 06/23/2016 $27.97 Class of Work: Type of Const: Info Process/Archiving-Sm$0.50(up to 06/23/2016 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $106.78 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: <:94, Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection ••te. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System RECEIVED FOR OFFICE USE 011.1• " CI of Ti and Received `.7 g c Date/B . .'�3 >,47 ( Permit No.:F/0�pao ,.t�CVO 13125 SW Hall Blvd.,Tigard,OR 97223 JUN 2 3 2016 Plan Review Phone: 503.718.2439. Fax: 503.59 8.1960 Date/By: Other PermitSR X 06' dd0, Inspection Line: 503.639.4175 Date Ready/By: JurisH See Page 2 for www.tigard-or.gov BUILDING- DIVISION Notified/Method: Supplemental Information` - pp ir W I i 1 2-F IL b INS ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OI CONSTRUCTION . work indicated on this application. Valuation: ❑ 1-and 2-family dwelling ®Commercial/industrial $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: O) SITE` ATI o t LU* f" Total number of floors: Job site address1,95WSW WASHINGTON SQ RD New dwelling area: square feet City/State/ZIP:PORTLAND,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.:FC09 Project name:CHARLEY'S PHILLY STEAKS Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED D: e'w USE '. Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the r x work indicated on this application. DESC ,ION OI��7JVRK � • ,� PP CHANGE HEADS AS REQUIRED*FOR TI Valuation: $$1,144.00 (9,) Existing building area: square feet New building area: 0 square feet ERS 0 TENANT., Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Ordinary 1 A- Phone:( ) Fax:( ) New: II ® APPLICANT ,• $ '14 CONTA 11 O NOTICE . Business name:Wyatt Fire Protection All contractors and subcontractors are required to be Contact name:Max Colley licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:9095 SW Burnham Rd jurisdiction in which work is being performed.If the City/State/ZIP:Tigard,OR 97223 applicant is exempt from licensing,the following reasons apply: Phone:(503)684-2928 Fax::( ) E-mail:m.colley@wyattfire.com a t ti , CONTRACTOR l IIILDI] /'P FEE 11 Business name:Wyatt Fire Protection (Please ev d`i7e �< Permit fee: Address: State surcharge(12%of permit fee): City/State/ZIP: FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application.) CCB lic.:64077 � Total permit fees: Authorized signature: _ _ Amount received: This permit application expires if a permit is not obtained Print name:Max Colley Date:6/23/16 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Pennits\FPS-PennitApp.doc Rev 01/05/2012 440.4613T(11/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: ; ' ` 1.) ❑ New 2.) Modification to sprinkler heads only: ® Addition ® 1-10 heads: No plan review required. El Alteration ❑ 11+ heads: Plan review required. El Repair Number of sprinkler heads: 9 Additional description of work: 'T a of S st m (Complete A,B,C orD s pplicabl ) .54„ rcial Sprinkler ® Wet ❑ Dry Additional Standpipes 0 Information: Hazard Group Ordinary 1 Density 0.15 Design Area 1500 K. Factor 5.6 Sprinkler Project Valuation: $ 1144 B.) ;`:Type/ Hood re Suppress on `stem �Y u k Hood Project Valuation: $ Submittal shall Battery Calculations ❑ Yes include: Individual Component El Yes Cut Sheets Fire Alarm Project Valuation: $ ;Y Y� t. D.) Residents .tinler(Stand Ali . ystent „A" Square Footage: Permit Fee: 0 to 2,000 $198.751. 2,001 to 3,600 $246.45 4111 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. :, Fire Prote q 'erm t Fees Project valuation subtotal(see A,B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. W:\Max\1112 PERMIT APPLICATIONS\Tigard App.doc Rev 01/05/2012 2 City of Tigard Permit No.: 47C7/ -- D0/06 13125 SW Hall Blvd.,Tigard,OR 97223 >s Phone: 503.718.2439 Fax: 503.598.1960 Date Received: / 1//6 T!G A R D Inspection Line: 503.639.4175 Internet: www.tigard-or.gov By: FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONIRECEIVED OR TENANT IMPROVEMENTS JUN 2 3 2016 (1 to 10 SPRINKLER HEADS WITHOUT PLANS))Y OF TIGARD BUILDING DIVISION Project Name: Charley's Philly Steaks Occupancy: Ordinary 1 Job Address: 9585 SW Washington Sq Rd Type of Construction: Suite: Contractor: Wyatt Fire Protection Phone: 503-684-2928 Number of Proposed or Altered Heads: 9 Type: SSP Hazard: Ordinary 1 Density: 0.15 I, Max Colley, Wyatt Fire Protection Oregon Construction Contractors Board No. 64077 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams, partitions,walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads (see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: __ — Date: 6/23/2016 Print Name: ax Colley I:\Building\Forms\FireSprinklerAffidavit_071514.docx Page 1 of 1