Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (12)
fi f f DWGS. No. CONVENTION HVAC SYMBOLS HVAC SYMBOLS REMODEL SYMBOL GENERAL PROVISIONS MECHANICAL DESIGN CRITERIA RKEIVED �pFROF O BUILDING LEVEL SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRPTION 1. FURNISH AND INSTALL ALL ITEMS, INCLUDING EVERY ARTICLE, DEVICE, OR ACCESSORY MECHANICAL DESIGN CONDITIONS: �'�CGNI E DRAWING 1, 2, & 3 NEW DUCTWORK INDICATED BOLD DUCT r-W NEW OR RLOCATED DUCTWORK SHOWN WITH REASONABLY NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTIONING AS INDICATED JUN 8 2015 L'� � 89617FE yy/p DIMENSIONS ARE INDICATED IN INCHES, S-CHWS--S CHILLED WATER SUPPLY BOLD LINES. BY THE DESIGN AND THE EQUIPMENT SPECIFIED. ELEMENTS OF THE WORK SHALL SUMMER MZ.Z INSIDE CLEAR, FIRST IS SIDE SHOWN �CHWR� CHILLED WATER RETURN yy/p EXISTING DUCTWORK TO REMAIN IN PLACE INCLUDE, BUT ARE NOT LIMITED TO, MATERIALS, LABOR, SUPERVISION, SUPPLIES, l;lI '�3h 'IUAIti1 ` -40 OREGON o DUCTWORK WITH ACOUSTIC LINING. INSIDES INDICATED WITH FINE LINES EQUIPMENT, TRANSPORTATION, HOISTING/RIGGING, STORAGE, UTILITIES, AND ALL OUTDOOR DESIGN: 93• F DB / 75• F WB L CLEAR DIMENSION, INCLUDING ACOUSTICAL BCH i SECONDARY CHILLED WATER - - EXISTING DUCTWORK TO BE REMOVED REQUIRED PERMITS AND LICENSES. INDOOR DESIGN: 75• F DB / 50% RH BUILDING DIVISION "O FMeER�$' P`� INDICATED DASHED. 9i1�. S 1� DISCIPLINE w LINING. SUPPLY - - CONDENSER DESIGN: 105' F DB OUTDOOR MECHANICAL DRAWING TYPE DUCTWORK WITH ACOUSTIC LINING AND SECONDARY CHILLED WATER EXISTING DUCTWORK TO BE RELOCATED 2. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE PORTIONS OF AMBIENT KA C 1.08.2015 s-scHwR� INDICATED DASHED AND CROSS HATCHED, 1 - DEMOLITION PLAN EXISTING DUCTWORK NEW LOCATION ALL NATIONAL, STATE, AND LOCAL CODES AND STANDARDS. WHERE THE CONTRACT WINTER: EXPIRES 06/30/2015 0- GENERAL LAGGING, INSIDE CLEAR DIM. INCLUDING RETURN ACOUSTICAL LINING. 2- DUCTWORK PLANS CWS CONDENSER WATER SUPPLY INDICATED BOLD DOCUMENTS ARE IN EXCESS OF CODE REQUIREMENTS, THE CONTRACT DOCUMENTS 3- EQUIPMENT SCHEDULES ROUND DUCTWORK. D = DIAMETER EXISTING DUCTWORK WITH EXISTING SPIN-IN SHALL GOVERN. IN THE EVENT OF A CONFLICT BETWEEN THE CONTRACT DOCUMENTS OUTDOOR DESIGN: -8' F DB 4- MECHANICAL DETAILS S-CWR CONDENSER WATER RETURN CONNECTION, EXISTING FLEX DUCT AND AND APPLICABLE CODES, THE LATTER SHALL GOVERN. INDOOR DESIGN: 75' F DB FLAT OVAL DUCTWORK EXISTING PLENUM SLOT DIFFUSER INDICATE i WITH FINE UNE. 5--HWS-i HOT WATER SUPPLY3. FIELD VERIFICATION OF EXISTING CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONCENTRIC DUCTWORK TRANSITION 15' RELOCA s EXISTING DUCTWORK WITH EXISTING SPIN-IN DESIGNATION TAGS IMAXIMUM S-HWI2-I HOT WATER RETURN Q CONNECTION, NEW FLEX DUCT (REUSE CONTRACTOR. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY ECCENTRIC DUCTWORK TRANSITION 15' EXISTING FLEX DUCT WHEN EVER POSSIBLE) DISCREPANCIES FOUND PRIOR TO SUBMISSION OF BID. THE CONTRACTOR SHALL MAXIMUM S-HTHHWS _jHIGH TEMPERATURE HEATING HOT WATER - S AND EXISTING PLENUM SLOT DIFFUSER. IF TAKE NOTE THAT THE DRAWINGS ARE SCHEMATIC IN NATURE AND INDICATE THE ""�""� " SUPPLY r CONFLICT EXITS BETWEEN EXISTING PLENUM APPROXIMATE LOCATIONS OF THE HVAC AND PLUMBING SYSTEMS. LOCATE ALL AIR DEVICE AIR QUANTITY f-i FLEXIBLE CONNECTION AT EQUIPMENT HIGH TEMPERATURE HEATING HOT WATER SLOT DIFFUSER AND NEW PARTITION ITEMS BY ON-THE-JOB MEASUREMENTS. COOPERATE WITH OTHER TRADES TO SrHTHHWR -5 RELOCATE PLENUM SLOT DIFFUSER AS DESIGNATION REFER TO PLANS ® RETURN `:' REQUIRE. ENSURE PROPER FIT AND ACCESS TO ALL ITEMS. A C SUPPLY OR POSITIVE PRESSURE DUCT MECHANICAL GENERAL NOTES (- SECTION VIEW INTO DUCT S-s--S STEAM SUPPLY EXISTING DUCTWORK WITH NEW SPIN-IN 4. CONSIDERATION SHALL NOT BE GRANTED FOR MISUNDERSTANDING OF THE SCOPE OR LAIR DEVICE RETURN / EXHAUST OR NEGATIVE CONNECTION, NEW FLEX DUCT AND NEW w CONNECTION SIZE ® PRESSURE DUCT SECTION VIEW INTO DUCT S-SYS-S 5 PSIG STEAM SUPPLY PLENUM SLOT DIFFUSER. AMOUNT OF WORK TO BE PERFORMED. TENDER OF A PROPOSAL CONVEYS FULL cn NEW EQUIPMENT _ EXISTING DUCTWORK HATH NEW SPIN-IN CONTRACTOR AGREEMENT OF THE ITEMS AND CONDITIONS SPECIFIED AND/OR 1. REFER TO DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS z DESIGNATION UNIT NUMBER �I SUPPLY OR POSITIVE PRESSURE DUCT S-50s 50 PSIG STEAM SUPPLY 1� �1 INDICATED, SCHEDULED, OR IMPLIED ON THE CONTRACT DOCUMENTS, AND/OR AND SCOPE OF WORK. O r �Lll�l SECTION AWAY FROM VIEWER 1��,'�I CONNECTION, NEW FLEX DUCT AND NEW / -xXX-x RETURN / EXHAUST OR NEGATIVE S-25o s-S 250 PSIG STEAM SQUARE CEILING OUTLET. REQUIRED BY THE NATURE OF THIS WORK. 2. VERIFY DIMENSIONS FROM ARCHITECTURAL DRAWINGS AND FROM ACTUAL LU 1- PRESSURE DUCT SECTION AWAY FROM 6UPPLY EXISTING DUCTWORK WITH EXISTING SPIN-IN MEASUREMENTS AT JOBSITE. to U LEVEL LOCATION VIEWER S-HCR�S HIGH PRESSURE CONDENSATE RETURN5 CONNECTION, NEW FLEX DUCT (REUSE 5. ALL WORK SHALL BE ARRANGED IN A NEAT, WELL ORGANIZED MANNER. ALL 3. INSTALL DUCTWORK AS HIGH AS POSSIBLE UNLESS NOTED OTHERWISE. z � RISER TYPE---i SUPPLY OR POSITIVE PRESSURE EXISTING FLEX DUCT WHEN EVER POSSIBLE) SERVICES SHALL BE ROUTED PARALLEL AND PERPENDICULAR TO THE PRIMARY DUCT UP S-PCR� PUMPED STEAM CONDENSATE RETURN AND EXISTING SQUARE CEILING DIFFUSER 4. COORDINATE AIR DEVICES WITH LIGHTING LAYOUT AND ARCHITECTURAL REFLECTED V) xx LINES OF THE BUILDING. LOCATE ALL OPERATING AND CONTROL EQUIPMENT RETURN / EXHAUST OR NEGATIVE RELOCATED. CEILING PLANS. I_ z 1 CLEARANCES. U Q PRESSURE DUCT UP EXISTING DUCTWORK WITH EXISTING CAPPED / RISER NUMBER PROPERLY TO PROVIDE CODE AND/OR MANUFACTURERS S-CR-i STEAM CONDENSATE RETURN I� SPIN-IN CONNECTION, AIR DEVICE SHOWN 5. ALL DUCT SIZES INDICATED ARE CLEAR INSIDE DIMENSIONS. ROUND DUCTWORK SLOPPED U J DASHED AND CROSS HATCHED TO BE Z U uDwr,-.- ❑ 6. AFTER COMPLETION OF INSTALLATION, BUT PRIOR TO SUBSTANTIAL COMPLETION, o GRAPHIC SYMBOLS -�� INCLINED RISE (R) OR DROP (D) RELATIVE -D� DRAIN LINE STOCK.REMOVED AND RETURN TO OWNERS CONTRACTOR SHALL CERTIFY IN WRITING THAT PRODUCTS AND MATERIALS INSTALLED 6. COORDINATE WORK COMPLETELY WITH ALL OTHER TRADES. F- 1.- LU TI DIRECTION OF AIR FLOW �Dw-i DOMESTIC WATER AND PROCESSES USED DO NOT CONTAIN ASBESTOS OR POLYCHLORINATED 7. WHERE THERMOSTATS ARE LOCATED ADJACENT TO LIGHTING FIXTURE SWITCHES, u O INTERNALLY UNEN RETURN AIR BOOT WITH 1�I�J MANUAL BALANCING DAMPER OPPOSED OPENINGS LOCATED ON BOTroN of Boor. BIPHENYL (PCB). THE THERMOSTAT SHALL BE ALIGNED WITH THE LIGHT SWITCH. MOUNT ALL SECTION OR DETAIL �7 BLADE TYPE THERMOSTATS AT 48" AFF, UNLESS NOTED OTHERWISE. REFER TO DEVICE LU U w NUMBER 5-►---� DIRECTION OF FLOW INTERNALLY LINEN RETURN AIR BOOT WITH p �C AUTOMATIC DAMPER (A.D.) OPENINGS LOCATED ON TOP OF BOOT. 7. IN THE EVENT THAT MATERIALS, PRODUCTS, AND/OR PROCESSES BEING PROPOSED COORDINATION DETAIL FOR ADDITIONAL INFORMATION. F DRAWING TITLE CURTAIN DAMPER f-O PIPE RISING INTERNALLY UNEN RETURN AIR ELBOW FOR THIS PROJECT CONTAIN, OR MAY EMIT, ANY VOLATILE ORGANIC COMPOUNDS WITHOUT TURNING BANES. (VOC), FORMALDEHYDE FORMULATIONS, OR HAZARDOUS OUT-GASSING, AS 8. OUTSIDE AIR INTAKES SHALL BE LOCATED A MINIMUM OF WINGS. HORIZONTALLY "' XX DRAWING TITLE � � LINK - STYLE " A" (FRAME AND BLADES PIPE TURNING DOWN AWAY FROM EXHAUST AND SANITARY VENT DISCHARGE OPENINGS. IN AIR STREAM DETERMINED BY THE MANUFACTURER, A MATERIALS SAFETY DATA SHEET SHALL BE w o 0 SCALE:XIX" I'-0` SUBMITTED AS PART OF THE SHIP DRAWING PROCESS FOR REVIEW BY THE ~ ���- LINK - STYLE " B" (BLADES OUT OF AIR �� VENTED "P` TRAP NEW EQUIPMENT SHOWN BOILS AND 9. CONTROL WIRING OUTSIDE BUILDING SHALL BE IN CONDUIT (SEAL-TITE). Q DRAWING SCALE T STREAM FOR REDUCED AIR FLOW Y s HATCHED. ARCHITECT/ENGINEER/OWNER. RESTRICTION �I` VALVE ON RISER SECTION NO. CURTAIN TYPE FIRE DAMPER FUSIBLE f- 8. ALL EQUIPMENT AND MATERIAL TO BE FURNISHED AND INSTALLED ON THIS PROJECT o 0 DIRECTION OF LU I`IL�U LINK - STYLE " B" IN HORIZONTAL S--L�-i CONCENTRIC REDUCER EXISTING EQUIPMENT RELOCATED SHOWN SHALL BE UL OR ETL LISTED, IN ACCORDANCE WITH THE AUTHORITY HAVING 1 r CUTTING PLANE POSITION. I BOILS AND No HATCH. JURISDICTION, AND SUITABLE FOR ITS INTENDED USE ON THIS PROJECT. S--CI--S ECCENTRIC REDUCER Y 6.01 ® BACK DRAFT DAMPER € Q r rV LB N-JEXISTING EUIPMENT TO ION 2004 FS FLOW SWITCH SHOWN W/°FINE LINES. REMAIN IN PLACE 9' F RMTAT. COPIERONIC S OF RTHE ELECTTHE RONIC C JECT I MEDIA( WILL BE AVAILABLE E VIAIN AUTOCAD SE AIL OR OUTSIDE AIR CALCULATION SHEET NO. OF THE RECTANGULAR ELBOW WIHTOUT TURNING PITCH COMPACT DISK (CD-ROM). THE ELECTRONIC MEDIA IS FOR THE INTENDED USE PACKAGE ON WHICH �;= VANES �� PITCH PIPE DOWN IN DIRECTION OF ARROW AIR FLOW DIRECTIONAL INDICATOR. ( ) SECTION DRAWN. SUPPLY OF THIS PROJECT ONLY AND SHALL NOT BE USED BY ANY PARTY, IN WHOLE OUTSIDE AIR SHALL BE PROVIDED IN ACCORDANCE WITH ASHRAE 62.1-2010. THE REQUIRED AIR FLOW DIRECTIONAL INDICATOR. (RETUR OR IN PART, FOR ANY OTHER PROJECT. CONTRACTOR SHALL HAVE AN ACCEPTANCE RECTANGULAR ELBOW WIHT TURNING VANES THERMOMETER AND WELL -a OUTSIDE AIR VENTILATION WAS CALCULATED AS FOLLOWS: DRAWN: ML EXAMPLE: ASSUME A SECTION IS CUT ON OR EXHAUST PERIOD OF 10-WORKING DAYS TO REVIEW AND ACCEPT ELECTRONIC MEDIA FILES DRAWING M2.01 WITH A TAG OF 1/M6.01 DELIVERED.THE SECTION No. 1 IS ON DRAWING No.M6.01. S-(J--� THERMOMETER WELL �� NEW PIPING INDICATED IN BOLD LINES RADIUS ELBOW WITHOUT TURNING VANES CHECKED: CB LiSET- (90• RADIUS ELBOW R=1.0 xW) -� EXISTING PIPING INDICATED WITH FlNE UNE THE ELECTRONIC MEDIA IS INTENDED TO ASSIST THE CONTRACTOR IN THE RECEPTION 5 30 0.06 1000 PRESSURE/TEMPERATURE TEST PLUG PREPARATION OF SHOP DRAWINGS FOR THIS PROJECT AND IS TO BE CONSIDERED CORRIDORS 0 0.06 1000 EXISTING PIPING TO BE REMOVED INDICATE AS GUIDE ONLY. THE ELECTRONIC MEDIA AS PROVIDED DOES NOT RELIEVE THE JOB No: 1314 DETAIL NO. RADIUS ELBOW WITH TURNING VANES (90' PRESSURE GAGE WITH GAGE COCK - WITH DASHED AND CROSS HATCHED. OFFICE 5 5 0.06 1000 w CONTRACTOR OF ANY CONTRACT RESPONSIBILITIES. R RADIUS ELBOW R=1.0 xW) _ STORAGE - - 0.12 1000 X \ r SQUARE TO ROUND DUCT TRANSITION GAGE COCK CAPD-f EXISTING PIPING INDICATED WITH FINE LINES, EXITING PIPING TO BE REMOVED THE CONTRACTOR AGREES TO PROVIDE THE OWNER AND ARCHITECT/ENGINEER BREAK ROOMS 5 50 0.12 1000 / INDICATED DASHED AND CROSS HATCED. AN ELECTRONIC MEDIA COPY OF THE "RECORD DRAWINGS" IN THE SAME SHEET NO. ON WHICH I 1 ® I NEW OR RELOCATED ZONE THERMOSTAT FORMAT AS INDICATED ABOVE. CLASSROOMS 10 35 0.12 1000 THE ENLARGED DETAIL-] AIR EXTRACTOR WITH ADJUSTABLE 5-X PIPE ANCHOR NQ. (_-_- SHOWN BOLD. WAITING 7.5 50 0.06 1000 IS DRAWN. / OPERATOR --- AREA OF DETAIL AIR EXTRACTOR WITHOUT ADJUSTABLE i)( X PLENUM RATED TUBING E T EXISTING ZONE THERMOSTAT SHOWN W/ THE CONTRACTOR SHALL SUBMIT ALL REQUESTS IN WRITING TO THE ENGINEER ENLARGED OPERATOR --.T •-- FINE LINES, TO REMAIN IN PLACE. FOR ELECTRONIC MEDIA. STANDARD SMACNA PRESSURE TAP WITH �-AJ--f UNION Vbz = RpPz+RaAz SCOOP TYPE SPLITTER DAMPER SUPPLY 10. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL COORDINATE THE ( j� EXISTING ZONE THERMOSTAT SHOWN Voz = Vbz/Ez (WHERE Ez = 0.8) AIR ONLY) DASHED AND CROSS HATCHED TO BE INSTALLATION OF DUCTWORK, CONDUIT, CABLE, ECT., INSTALLATION WITH LIGHTING (9-KEYED NOTE STANDARD SMACNA PRESSURE TAP W/o FLANGED JOINT T RELOCATED. FIXTURES, SPECIAL CEILING CONSTRUCTION, AIR DISTRIBUTION EQUIPMENT, AND SCOOP TYPE SPUTTER DAMPER (RETURN _m_._--___-_. THE STRUCTURE. PROVIDE ADDITIONAL RISES AND OFFSETS AS REQUIRED. IF, OA REQ'D OR EXHAUST AIR ONLY) WELDED JOINT AFTER INSTALLED, NEW DUCTWORK, CONDUIT, OR CABLE IS FOUND TO BE IN ROUND SPIN-IN TAP WITH BALANCING CONFLICT WITH THE ARCHITECTURE, STRUCTURE, OR OTHER TRADE WORK, WHICH Ra Az Vbz Voz Jensen / Fey DAMPER AND RIGID ROUND. SCREWED JOINT IS EITHER EXISITNG OR SHOWN ON THE CONTRACT DOCUMENTS, THE DUCTWORK, RECEPTION 5 13.4 0.06 447 93.8 117.3 DEFAULT GROOVED END JOINT CONDUIT, OR CABLE SHALL BE RELOCATED WITHOUT ADDITIONAL COST TO PIPING DESIGNATION ROUND SPIN-IN TAP W/0 BALANCING OFFICE AREAS 5 6.9 0.06 1,378 117.1 146.4 DEFAULT 7730 LEARY WAY NE Architecture and Planning DAMPER AND RIGID ROUND. THE OWNER. CORRIDORS - - 0.06 1,196 71.8 89.7 DEFAULT REDMOND, WA 98052 EXAMPLE: T SPUTER DAMPER AUTOMATIC AIR VENT WITH DRAIN LINE 11. MATERIALS AND EQUIPMENT SHALL BE NEW AND IN GOOD CONDITION. THE STORAGE - - 0.12 127 15.2 19.1 DEFAULT TEL:425.216.0318 FAX:425.216.0329 SYSTEM SERVICE - COMMERCIALLY STANDARD ITEMS OF EQUIPMENT AND THE SPECIFIC NAMES BREAK ROOM 5 8.4 0.12 168 62.2 77.7 DEFAULT rABBREVIATION INDICATED ARE INTENDED TO IDENTIFY STANDARDS OF QUALITY AND PERFORMANCE CHWsqP "Y" TYPE STRAINER WITH DRAIN SUPPLY SIDEWALL REGISTER WITH VOLUME VALVE AND CAP NECESSARY FOR THE PROPER FUNCTIONING OF THE WORK. MATERIALS AND CLASSROOMS 10 17.3 0.12 493 231.7 289.6 DEFAULT NOMINAL PIPE SIZE AIR EXTRCTOR. EQUIPMENT, WHICH ARE FOUND TO HAVE FACTORY DEFECTS SHALL BE REPLACED WAITING 7.5 15 0.06 1,637 210.7 263.4 ACTUAL (SIZE IN INCHES) ® F.D. FLOOR DRAIN. REFER TO OR REPAIRED IN A MANNER ACCEPTABLE TO THE OWNER AND ENGINEER AT NO RETURN OR EXHAUST SIDEWALL REGISTER PLUMBING DRAWINGS ADDITIONAL COST TO THE OWNER. f--Da� STOP VALVE MISCELLANEOUS ROUND SPIN-IN TAP WITH BALANCING F 12. THE CONTRACTOR SHALL PROTECT THE WORK, EQUIPMENT, AND MATERIALS FROM TOTAL REQ'D 1,004 DAMPER AND FLEXIBLE DUCT. � "F" AND `T" TRAP DAMAGE BY HIS WORK OR HIS PERSONNEL, AND SHALL CORRECT ALL DAMAGE PROVIDED 1,055 THUS CAUSED WITHOUT ADDITIONAL COST TO THE OWNER. THE CONTRACTOR f-- PIPE BREAK ROUND SPIN-IN TAP W/O BALANCING BASKET TYPE STRAINER WITH DRAIN SHALL BE RESPONSIBLE FOR ALL WORK, MATERIALS, AND EQUIPMENT UNTIL FLOW ARROW DAMPER AND FLEXIBLE DUCT. - VALVE FINAL ACCEPTANCE BY THE OWNER_ PROTECT ALL WORK AGAINST THEFT, - -- R DAMAGE AND CAREFULLY STORE MATERIAL AND EQUIPMENT RECEIVED 1,004 .CFM OF OUTSIDE AIR IS REQUIRED, 1,055 CFM 0 UTSIDE AIR IS PROVIDED BY SQUARE TO ROUND TAP FITTING WITHOUT � Q � STRAIGHT THROUGH CONTROL ON SITE WHICH IS NOT IMMEDIATELY INSTALLED. THE CONTRACTOR SHALL DUCT BREAK BALANCING DAMPER. f--D�4-� VALVE ABBREVIATIONS CLOSE OPEN ENDS OF WORK WITH TEMPORARY COVERS OR PLUGS DURING THE" ABU'S, THEREFORE THE OUTSIDE AIR REQUIREME .S AR SATISFIED. POINT OF CONNECTION SQUARE TO ROUND TAP FITTING WITH® CONSTRUCTION TO PREVENT THE ENTRY OF DUST, DIRT, AND OBSTRUCTING(NEW TO EXISTING) BALANCING DAMPER. 3-WAY CONTROL VALVE ACCU AIR COOLED CONDENSING UNIT. MATERIAL. THE CONTRACTOR SHALL PROTECT ALL EQUIPMENT AND MATERIALS FROM ® \ / f--I�r-f CRAHU COMPUTER ROOM AIR HANDLING UNIT. DAMAGE DUE TO WATER, SPRAY-ON FIREPROOFING, CONSTRUCTION DEBRIS, POINT OF DISCONNECTION SWING CHECK VALVE OAHU OUTSIDE AIR- AIR HANDLING UNIT. ETC. IN A MANNER ACCEPTABLE TO THE ENGINEER AND/OR OWNER. PIPE SECTION OO ROUND SUPPLY AHU AIR HANDLER UNIT. A, DIFFUSER NON-SLAM SPRING OPERATED FCU FAN COIL UNIT. (N) NOTATION - NEW ITEM -- 24"x24" (4)-WAY THROW PATTERN SQUARE CHECK VALVE 13. MECHANICAL EQUIPMENT SHALL BE IDENTIFIED BY MEANS OF NAMEPLATES FPTU FAN POWERED TERMINAL UNIT. PERMANENTLY ATTACHED TO THE EQUIPMENT. NAMEPLATES SHALL BE BLACK (NOTATION SHOWN AS NECCESARY FOR ® CEING OUTLET t--IIF-� FLOWMETER, ORIFICE VAV VARIABLE AIR VOLUME UNIT. SURFACE, WHITE CORE LAMINATED BAKELITE WITH ENGRAVED LETTERS. PLATES SHALL _ _ _ MY OF�TIGARD CLARIFICATION) EDH ELECTRO DUCT HEATER. BE A MINIMUM OF 3" LONG BY 1" WIDE WITH WHITE LETTERS 1 4" HIGH. f � ' 24"x24" (3)-WAY THROW PATTERN SQUARE f--BiEI� PLUG VALVE HM HOT WATER HEATER. / r}]� T ��✓t-/ r\ (E) NOTATION - EXISTING ITEM TO REMAIN. CEING OUTLET GUH GAS UNIT HEATER. [\tkj l J ` REVIE D POR CODE COMPLYANCE (NDTATION SHOWN AS NECCESARY FOR F--I� BUTTERFLY VALVE EUH ELECTRIC UNIT HEATER. A row d: CLARIFICATION) 24`x24" (2)-WAY THROW PATTERN SQUARE RTU ROOF TOP UNIL r��Cs, PP (L( 'iiii (R) NOTATION - EXISTING ITEM TO BE RELOCATED ®� CEING OUTLET CHWP CHILLED WATER PUMP. OTCs 1� J f--1110--f BALANCING VALVE M PCHWP PRIMARY CHILLED WATER PUMP. f (NOTATION SHOWN AS NECCESARY FOR �J 24"x24" (2)-WAY THROW PATTERN SQUARE GLOVE VALVE SCHWP SECONDARY CHILLED WATER PUMP. PermitM. Address: b�' CSU N CLARIFICATION) CEING OUTLET CWP CONDENSER WATER PUMP. (D) NOTATION - EXISTING ITEM TO BE DEMOLISHED AP ACCESS PANEL I� FLOWMETER, VENTURI o (NOTATION SHOWN AS NECCESARY FOR ® 24`x24" (2)-WAY THROW PATTERN SQUARE ASD ACCESS SERVICE DOOR Suite#• CEING OUTLET AD AREA DRAIN PRESSURE RELIEF VALVE . CLARIFICATION) PLENUM SLOT DIFFUSER - REFER TO SA SUPPLY AIR �� Date: 1 ' AIR DEVICE SCHEDULE FOR PRV RA RETURN AIRAlu O ADDITIONAL INFORMATION. PRESSURE REDUCING STATION OA OUTSIDE AIR EXISTING PIPE TO EXISTNG PIPING SHOW SUPPLY AIR DEVIVICE W/ INSULATED SHEET ROA RAW OR UNTREATED OUTSIDE AIR REMAIN IN PLACE DASHED AND CROSS METAL PLENUM IN LOW CLEARANCE. INVERTED BUCKET TRAP BTU BRITISH THERMALL UNIT -6 HATCHED TO BE y. RETURN OR EXHAUST AIR DEVIVICE W/ B BTUHR BRITISH THERMAL UNIT PER HOUR rz REMOVED. -� INSULATED SHEET METAL PLENUM IN LOW CFM CUBIT FEET PER MINUTE OFFICE COPY CLEARANCE. T TEMPERATURE SENSOR A COMPRESS AIR LINE LIMITS OF EXISTING FOB FLAT ON BOTTOM TRANSITION ,� a ITEM TO BE REMOVED. FOT FLAT ON TOP TRANSITION I �-J d _ SLIP-IN TYPE ELECTRIC DUCT HEATER W/ FM PRV PRESSURE RELIEF VALVE ( t C; 42" MINIMUM NATIONAL ELECTRIC CODE FLOW METER I L d SERVICE CLEARANCES PRS PRESSURE RELIEF STATION l rnrn Q " P PRESSURE SENSOR V' Q a HEATING HOT WATER COIL WITH SERVICE O c ACCESS DOOR DP DIFFERENTIAL PRESSURE d \ � 1 CHILLED WATER RISER �/ STEAM HUMIDIFIER INDEX OF DRAWINGS > LLL���lll CONDENSER WATER RISERLf) O +- UCD 1" UNDERCUT DOOR (UNDERCUT HIEGHT 0�1 SHOWN NO. DESCRIPTION CM m u 1 HEATING HOT WATER RISER / ^ FLEXIBLE DUCTWORK v , LLJ a T THERMOSTAT OR TEMPERATURE SENSOR CR CONDENSATE RETURN RISER MO.O MECHANICAL COVER SHEET W U v O MOUNTED AT +48` A.F.F. rfoo _j •` v TS STEAM RISER M2.1 MECHANICAL LEVEL 1 PLAN 0 o V ELECTRONIC TEMPERATURE 1 V „ E.S. RENSOR M2.2 MECHANICAL LEVEL 2 PLAN O oM o H HUMIDISTAT SENSOR OR HUMIDITY CONTROL E N �, O TOILET EXHAUST RISER M2.3 MECHANICAL LEVEL 3 PLAN E 1 M2.4 MECHANICAL ATTIC EQUIPMENT PLATFORM LEVEL PLAN Ln o � R FREEZE THERMOSTAT - LOW LIMIT ro O SE 1 SMOKE EXHAUST RISER c U X N m © CARBON DIOXIDE SENSOR M3.1 MECHANICAL CHILLED WATER PIPING SCHEMATIC L.(1 a v ~ ,;, V ® K' KITCHEN EXHAUST RISER M3.2 WIND TUNNEL HEAT EXCHANGER DETAILS >` CO o E v ;, TEMPERATURE SENSOR U •• ® S' SUPPLY AIR RISER mechanical electrical plumbing o FLOW SENSOR M4.1 MECHANICAL SCHEDULES n to Q a LL RA M4.2 MECHANICAL SCHEDULES . SD SMOKE DETECTOR 1 RETURN AIR RISER DIFERENSIAL PRESSURE SENSOR 1 STAIR PRESSURIZATION RISER M5.2 MECHANICAL DETAILS 1 OUTSIDE AIR RISER . SHEET: © STATIC PRESSURE SENSOR OA M5.3 MECHANICAL DETAILS p SP M5.1 MECHANICAL DETAILS ssoc�a OF FIRESTAT OA es 1 RAW OUTSIDE AIR RISER CONTROL TUBING OR WIRING BRA BUILDING RELIEF AIR RISER C O ns u Iti n g Engineers 1 GENERAL. NOTES 8217 Shoal Creek Blvd THIS IS A STANDARD LEGEND SHEET. SOME INFORMATION ON THIS SHEET MAY NOT NECESSARY APPLY TO THIS PROJECT. Suite 100 momo Austin, Texas 78757 512-407-9011 512-407-8287 (fax) F:. N 2 �Ip PRwo O �� C,INE s, 17 ELECTRICAL EQUIPMENT lz w 89617PE _P 9 PROVIDE ISOLATION BUTTERFLY SHOWN FOR COORDINATION I ;j Ir VALVES WITH A BLIND FLANGE �_ _. _ -.-,��-__.� _ --- -,,- >.� -- -� -- T�----� 1 ONLY a -- x_ - _=__,s-a�7-� -_,�_ � �-�_:=_ -mss ^ ___-_. :ter. :-.<=____::_- __� -.-= ? - _._._-w z, �_�-z r .� :Y fir- ___ __�..- __— .sac- FOR FUTURE CONNECTION OF --- -- - - , OREGON ROLL UP CHILLER - r1 ---._--.- -. " ..-______._...._ _ ____,_________. _.._.,__._ _ .__-- _-___. ..... ._ _ .._ .... . -_.._ CHWP-1 I. GOLF �$ ��� O11,,z I � McER 1 S: �� '° EKA`l.11 C1.Ci8.2C�15 I 4:1k_I EXPIRES 06/30/2015 : I1 I 1 ! ! r_.___-. _- _- _.__.. ..._1-I- _ " ._. __._ ? - j l i I 17 � i CH-1 t \ I - 23 11 I 14,721 LBS. REFER TO CHILLED WATER __ 1 I - PIPING SCHEMATIC 1/M301 I /r �� ! ; -- -- FOR ADDITIONAL INFORMATION • 17 '� i REGARDING CHILLED WATER i - - ',�__-_", z---- '°ty�\4 ,r -_�, ' ' qY^�}.g(� I �)11 - / ] , �gy ,`} �' Ply � PIPING AND SIZES:, j tfy\ 1 r'--,� r•9^_"y�� I t i- ( 6 fj i 4 1' ' .k% t s } i / I ��/// 1 � - rr'+..°�a�� t ,:.�S' � 3! � .-...�t� � � S.a\ ! .O 6 i ' � [/� \.__;_/ _rf' __ I `f`'` 21 21 '_, i �--,f\ '--1. �'�--ter `` '1 Z _,- 4�4 r __ �� I ± 1.L , ! L_' \ i O - 9 __.____- 1 i i I ! : ___-__.._- ; �n : ! _____ ___ f i I i I ( 4 rirl ^ Z � I 2 I 16 t-,1= - -- _- _- _-_-_-_ -_-CHWS� - -- -- -- -- -- --_-_-_- - - -- -- --' - -- I O .V) —�— N �_ - --_! ;_ - - - - - - -- -- -- - --- - - - pCH�-1!IS - -- - - -- - - -- - - - - -, !:1 - -- - - -- - - --t�-CHWR - - - -- -- -------- ^` - - - - -_ - --- x H i Uz i - - - - - --- -- - -- - -- -- - - - - --- - - - - - - ---- - - - - I - - - - T-- ! Z � � I � - - - -- -- �- - - - - - -- -- - - - - - - - - - - - - - - ---- - --- - - II i _ � ' .- -,,- . CA-IWR �` N I I o �� , -r_ - I I - Z r i ,' !C, �w 16 = I I , LINK SEAL PROVIDE ISOLATION BUTTERFLY i I • ` i `. ' I ! N AT WALL I I I I ' i I I i 1 VA i ,� j Riser Rm 1 1 11 i w w LYES AT CHILLER CONNECTION PENETRATION I t ! j 1 ! i ' i I I 1 1 i o ce TO ISOLATE CHILLER DURING i __�.- _ __ __. _._ _ _- ___ _.._ . L. .L. I. L . _.__1_ ; _I I ? i REMOTE CHILLER OPERATION ! i - ; O . } I I 1 1 N SEAL } 115 LI K i iAT WALL ! _ .. - - -.... -- - - - -- _ -- -- -- - a _ - i - i _ *___4+...__ i i I i - _ _..--- --- ---- ,- -__ .--T.-_,._ __� _- -__, i I r'`• �� PENETRATION EUH 3 }t: I- 0 I i`` , 14 Q I �"_ I I 1 , is I i 00 N --_.: __ ._...._ ._._. __ _._ _____ .. __.__.--_.--_._-_-_ --- _ - _ _._.__-.__ _ __.____._. -__ P`` !' - ! I I i i- i I 1- i I "Pr _ 2� \ _ t+} ! .._.___-.__..._ 1 \_._.,_..% ' ; , I i1 I 1 I t _i 1. ! T- ---_, i i i �� i ! ± _ , i —— I ! ! �c�--''' O _ - _ _ _ _ -_ _ _ _____ _ _ - _ _ _ — i _-_.-___ __..- ------._...__-----'----._.....--'--'- -I-H _.. ..... *-t---. ',,.r ,a,.>s,.,,...,� w�.,...r �...,...,r�„<..,,..,�,,,. ..,.�.,.q,rw.twn.+M.�.. . "....•'•_',`_ w..� _.--'---, _.'--'-a_ ,.�.-r. _ J: 1. . ._.__ .... ._". .. .___________._.___._....-- _ \ \ \ __ -.. ji -- - ----- - - - r T - _ - - t _ _ -- — - ._------_-, -,_.-.-• __ _. W,.z . _ x..4 w n x a_ w. ten,5.R.ue.w �, �. .,y, ter.- 3I`�x _u <a�. !} I.. .,. . . . . a .� .,, t.n.r� Y r _ .-�.. - _ _ . I} -- 1- i }- . !.. , n ! Ali Ii , t,, - N I � , � INSTALL D � I �� _ _ Q t::"::a - 6 -,.. . s ,I„ , I i I I ! ! 1 I i ! i' PROVIDE T STAT WITH Ad I I i ! 1 - - - - - -_.__-_.._._._ _._ _ 'i 2 I !,:.:::I .a 13 ,.. . 1 HIGH AS I - SCHEDULE 40^PVC INSIDE ii `�� ! 13 i ! I ! " , I ( ADDITIONAL CONTROLS WIRING - } i I i - I = ! ?� _ I i€ `` \. i ; i _ ; i ' `'� , POSSIBLE 1 i U� I \I \ ' i ;` TURN POCKET. 13 t I I� 1 i! i ` TO ALLOW FLEXIBLE LOCATIONSI i , ! :l it 1 1 - I 1 i ii i - f ! i L 3 i ti ;` ! i;::; t , - _ . � 1 ± a�` i iIfi ! r ± » » " ! i i s - i i DRAWN: ML 1 14 a>.{ \ti SCHEDULE 40 PVC INSIDE 1.1 } I 1 ? I I - I ! ;Ili ` I ! ,! j -� �i 60 X60 DRAINABLE LOUVER WITI� 4 1 j EDH1-3 i I I I 1. ' ! " / \ -' { :.;'3 TURN POCKET. ,';, _ - -- _. _-. _ I ! . a 1w, I I .,, / �— 1 : _ t �__�--_ _ DEEP-FARR_30 30 FILTER__RACK. i _- _ - + __.�_._. ,. -,u,.�..,_.Y_._�{..,_�_,�,.,�� c ili ; i } i. I 1 �' {!I� / - __ _ -- -;- ,, I j II CHECKED: �B (;:�:� ` t i ; E u i Rotim 1 - r = ;'i / \ t air 2 q p 1111 it i St o, �f) R " ;:iii /4n_ { ,<`r i> 1 9 � } 3 � \ I' 1 i !`:i \ 113 114 EUH-1 2 S' AHU -3"' ! Stair 3 ` '',i 1 Ii og No: 1314 I 1 ;I ,', \ ��1 Wim muu 1 i4 & l-4 iY e 1�....% \ / I!. !I II i \ ECH-1 u ;} \\� mnn imm 10 11 ECH-2 105 II -1 If ; �3c [; !t / Ii , I I 'i I q. 1 . ;1 :J I u r. i ,. . � _ �. x. I r J> �` i r -P �',�:,, �<. _ .,._.,r :.,. ,t�>.:t>_c �,, �,v _ : r E<t � .rN,,..�,rS,. .. � ._.,t ,z,,_.� , i+,rr.T h ' l 7 1 ` y } ' STUB FULL E RETURN AIR 0 ��ITS ° i / (} {! 11 ! i > s1z i AHu1 3 10 ; A, Rece ,,t } , II. ii 1 - I..::. u i f 1 i , I AHU1 4 0 i p �, �� f , ('•#;; i I f l r A DUCT THROUGH SOFT PARTITION v a S \ ii 1i :: \ - e�..__ n_.. \ __:____,. STACKED ,; Vestibule j` r l I ;: r MA FXi u�:_--s-----___- __ _ _..._. .. ,i : a. A 140 �f 1:I ! .i -; BY OTHERS i 1 I 11 ' ; /'' i ±i f I I ...7 ! ' DUCT HEATER ONLY s; h r 1 u { 20 20 - 1- - td i r'f '_ 11 11 ;'� \ !!: I , 109 ' I �� 2 0 _ s>t 104 / _ , 'I' / { 111 I i s [ I `SI/ ._..\ .,, PPLIES H 1 ;i ' ; , --MVD AHU1 1 I ;:':.. , I �... �.. '` u pati-... ._� !± \ / ,. ,1 ;. A TOA 3 �u l 3 i' !1 ; 1 `\ 1 I:.. 111 X. _. -- -_ - :., SFD N a ! l I! j +{ jA �, I. ,il x AHu1-2 %` i \.I } /� ; ;1. 8"0 i Cash Rm I f 1` y 1t4 i , + a , 1! ,e i `' i 11. I 1 4 I ` j l� i;; f.-._-'__ _-.__. _______ __ --f.-=-. -__._ 1 ._ 5 f 14 ( �y } } .;.'1 \ / ': i'' <<, I ,\ ,{4I D i 103 i; j _ _ -_.. _. __. _ __ i .} r �.. . 1 � , k sF , / , Architecture and Planning I :, lit A 300 \ J c I, l TORI-1 Ii �' ? , I` 9 ou f l.: \ <I I 7730 LEAKY WAY NE 1 I I I I _ u - -- _ 1. - -- - ' _. ! }, ?,, ! I r- r REDMOND,WA 98052 1 } i -- ,i 1 i i i _ - TYP. 2 i, ( i I _ — -: �- - I- ,a I ::y 1 ` -rT� I i 1I , , I,: O , 1 F:. s, i ii I ! TEL:425 .216.0318 FAX:425.216.0329 i t / i t i I I , 1 i ! i' i 1i ±I 7 i / i' i ! { J"_ it II I `! . ! , .� ` I;..::..1' _-._.-.___...�.Y,£ - ._.,_ .. , it , .. .. .. 6 II :1 �} +r {, r• 11 - 1i�i s - \ .i i 2 16 J I (` \ j ; ,. „ t. _ I r N 1 '._ i7 s \ . , 11 {I ! i'•. 11 i .:\ `lam N I r .. �, x4 } Jj' I \` / I r --- ..k ,i t is ' (i !' # 1 ;;�I, ! ! r ' r' t f: 1 i ,� - _ �T i- ------- INSTALL T'STAT BEHIND �\ w.__. __._. _ _.. i ! ,:, �` i. i i ..� 1._ i - > . } 1 - '--_ a ; RECEPTION COUNTER I i I i I ; '1 % } ! r i -_ .__, - - - :-'.-- '---_.-._ - . --- -7-'-"---,__-- -' -'-- - I ,.:4.I \.1. . J I± } I . i - � i t r----,I $ i I II ;.i t � t! : i, ( I ..T O __ I $ ! I I--- i i i I -,.. .. 7 -- __ �_ - __ - f ;,'-,'i s ,:..-; :' ti I ! rs� 1 C7 �ri i I} 1 j: i' j ' , I ,J _..- ;r % f !': :. , ; ! I _ EKHT<=M 1-�-- EKH1-2 4 .I I! 1 u I i h• .:i:� i I f - -t) C'___y I r I( 1 i / X ( R E r .-. 1 H `RAT D4 j \ . ..., I , . .. �t, � ! I 75 I i{. , D, ± i I ( , \. DUCT ENCLOSURE ! / .f i \ 6„� - 1 I ,.. � ; ! ! 1 I 1 COt�RDINATE LOCATION OF ! ( } r i; i - �` \ '. (, I '` i , ' I 1 KICKSPACE HEATERS WITHIN i -.':I /' iI . II i I ! I 1 „ .i ` % I I 1--l'i"'i,li, RECEPTION DESK MILLWORK WITH / if .. 11 11 / 'i� Toilet 1 t 3 TENANT i . NE / E 310 '\ \ }! f r- 1 !r �I __ ,! ,( ,t !4 I I/ 1 I `� } \ ;1 �\ ;t it 11 ! >j / I i t, r 111 G 125 1 I 14/14 I I 1 I } # 1 \ .I I i 1 % L - - --�-- ,� I_ ( I `� i Reception I i 'L ij /� 1 I % , ,.._. _-,... .-._yam_ —_. ..-_.__. —._._..__—._._._—_—._. ._,._.....,.,. __.__.__._-__..____. ___..__—_,- __._-_._ ..._._._.._...---_.__.__-...._...._____—___.,_._.._..______.___—._. _-.--_._ _ _ ...-.....-. .__.... ..__ ..- __..__.__._._-__ _._-__".____.__._...._____.___.__—___...___..__._.________.,...-_-___-__._--__,_._.. -_—___._--_—____ ___.___.__._.__.__.--_____--_,__.__ _-_____ . ; ,I ::{, UP-T0 ( _, -w 8 4i -0il. f __ L- -- ------ ='I---7 -- r-� rr- tw `T_ i - li- - ,, it ; / LVL 2` 11 } 1 ;t 8' I �.:::: I; I I : % _ ii I 1 I::a 1/ ;rl,. r 3 _I I-. i 1 C' C1 ii ? , :} �r l ! 102 1 `yyy' .i I t, _ , ; ' 1 I i, i. E 310 q j I �\.IF I ii N I� ,I...' :� — 5', Ny '..._'vi. -1 j Wit` ,f I I ! 1 I I I I ';i ,� "'• � y ' :.,F, !e .t _ _ n .__: J{ - . .. I 3I r 4 - ,L 4 I• I X y� ► i 1 y t, ,�. � r r > 8 t SS s 1 -,.. t 'x' C.1 -,.. i .i _.: , ! ... - __ I____ � ,e. � ,i , � Sat €t k ----'rY:- ,S. } .\��'e h.�.{ t_. { 'r`,m♦ 1 -s ,r:(,i t i , � ,If, "•-t I —.-_-_-- ._.__ _._ _ -- __._- - _.,-_t---�+, P':” n . �__L_ .. .:I - -• i`. ur c,a•` •,, ,,,k M. � , .Y 1, hi, v 8: iv l.n.b .b+ Tom' .may., .'. .. .. .. .. . ^1 _tl F .' ,. - hM SY/, u ,t .,• 1, tY,> 734. Y_ Y ) n>C:A<• Y< Sny- F. », y,, n.1!,i ,g „S .}. t i vn,„ yT"SJ f RN..Nrt , h A '.aA x, t 1 ± 1 iL, . .4: \ V _ m ? , l k. d � . .. .. s >s � ._ a9k, i"fit � ,,,.. tiulf�4ka.,, ,{ ds�J",S m`.,ttF �. ,, .s �,?;, .; I ..`� ,. ��. 1><ttr,„�rA,.u.\�t,,� roti} ., .,,. a. � s ", la, , I ... .,.-_________-.-_________-______.__._..___---.___..__.__..__._.-..___..______.._.__.____�_____-.a , . . .�, ,, : '�1'`.'u�ii�4f��tx�"~sar��,��M�;u�����sFc�.��,zn>;, rl, �l��.x „r�,;��c��w��r�;t�'ef��'.'�� ,y>��s .� k�.;��� �,� �. � '�, y���� �� ,��r. � '��� >�t�4,��.�.i�' � � >��.��;�<1 � _-.._ 1 % ` i i , - i, n - - r UP TO - , _ r i o 11 \ \ \ / \ i \, i \ \ \` + i i i i; vq�L# ` °' ;t VL 2 i i y I i L 1 I { C I I ♦.il - i1.-.---.,.-____C_ ________.___.U_ { �� _ _ r a es a ! i - I ! I I ; ,; } I .- - _._. __-. ..,_ __._ I E 3�/0 Ei 310 E 310: = l/�'/1 i i \ ; , ! ' Elevator 1 ' i , }_i II , i { 1 l ( ! } 106 I i i I ! , i! I ( I �>`/ t ` ; i ( I i 1 :1 ! i W ... - ._.__.. 1 I - S- 1 I I ! ___— _ __- __- ! I • - ,-_-�_-z.. _-���-'----:._.--_zr=�-�.�_,-.�,�r:-.ter-��-�: ..,..;--. ! I .,\, I i; 112 ,;. ., ; I S i J ! ii r � ____ _.__.__ _ - _,________ __ .._-.________-___.. _ _ ____________ _ ___ __ __- __��__� ____. .._._._.____________-.._ ___.___.__._-__ _ -_� ,_.JF�_.l 11 a I I' : t 11 t' a.. i 8 1 I I r=�__.-.__-.._ - ��'-.•-"'- _-_� -_-'__-w._—___.---; ' __ --_,.—. _-___..._...__ -+e-_-�.-.».,...-< ---_ .-._-""--_.-,._._. ^_ -` 1 r , ! . �. I _. P ! I 1 ,f —Imo. r---__--__'.__-____ I - 4 .i:- - < . I - I . } . i 8 i J i F O I TY P. "-,._ __.._______. -_ __ _ _ _ _ --_., _. _____ ��.-�, ;-1 I I } i! t . - { , i Ity�+ ( l I "�.?__'- 1 li .--- ,_.'_.`j( I f i I } iI 1 i tl k ' Q iI \ } j1 i�� ��•� AkiU2 'r,$ ! i i -`^--.- ,�,__` _ I ..'_`.�`_ I, i ! ', i 1 I ' 11 i , ` .--- 3 (� n \ (� i ! \1-- 1 1 II � `� ti %i i f I _-....y"�- -...c._--- _--_.'.. ±I 1 t I 1 i , 1 V I V 11 I }� i �../ [ !¢5 C I i I 11:JJ- - - �.-� }; I 1 ! - '__ - _E1 i i ! i i i i 1 ! !. i I ;I Q (� ___ i -• _ ; , �! ! _ ± I O ----�, 11 i i ! 1 , ` CY- CL } I 3 °L � ,� I i i I /-` 1 , -.." - __ { t..-_-_.._........_._....,W.....-..-_-,.,...-,_..:._.._.: --"'°-----c`-•--___'-- - -. .- ---- --- may.,-'-•___ "•,•--- .1--'- -,r-• ,: 'i-� -„ ., a --��^ -. i'— -i^•_-� S , i, I ♦ - ! I i i G 160 G 165 1 I! 1 I I i, ! I I 'j _ _ _ '.. , I \_._ • O i ( 8"� 8-aI ! 11 %I i ' I 1 {; '�J- Ii I i ! ! ; ■ i . » i 4'-0"L. 4 -0 L. i ! l 1 I �4; I i I s 1 i i i ( ,i I > L, O 1 1 ! m rn 1 I I ' ! i a ii ; l I ;i i1 t i j I '} z - o . U_. i �I MECHANICAL PLAN - LEVEL 1 "f , ! _ ;wr L`' — i 1 i i I I ! I ! , , Ln 01 . ; = i 1 : i ,I (, ! L w 1 I I 1 Scale: 1/4"= 1'-0" i p= ; « ( i I r 'L> t !k O ' as } i' , ! I i i i t 1 ;, i i 1 ,,0 V I ; ± 11 }'I 1 1 i i 1 i t-o o ■� S i 1 1 ! f i ; 1 1 ._"_!-_ t, N ,10 ON In " !_ _-- ---_ _"__-_�_.__--__- ____ _—_--- _- __ _.____ ___.. - _-- _ - --_.- ___ - -____ _ b _ -- --- - E 61 lfl ... __ I :L_ __________________ _._____-.________.._.._ __.-___-_____-____________.____......__ __......_______._ ______..____ _ __.----- ---______..__..__ ---- Y O o M II i I , i'-._....... .:..:. ......—._..__ ____.___.-._,_•___._ .._�'--._-_-:.....:,. -_-_. _._-'.._.-. ^.c.•- ."l_ __ ____ '_ _ _- _ _ _^M - .+ • ", O — � = _ � 4s KEYED NOTES: - �, - N Q v V T Q0 °` > C U1 t!; Urns ` .. 1O SEAL DUCT PENETRATION THROUGH WALL AIR TIGHT. gO PROVIDE REMOTE DAMPER OPERATORS FOR ALL DAMPERS LOCATED ABOVE INACCESSIBLE CEILINGS. 15 CHILLED WATER PIPING BELOW GRADE SHOWN DASHED. ROUTE BELOW GRADE CHILLED WATER PIPING AT >1 =5 ° x mechanical - electrical - plumbing -Y o •� M 2O SMOKE DEFECTOR SHOWN FOR REFERENCE ONLY AND PROVIDED BY ELECTRICAL CONTRACTOR, REFER TO OPERATORS SHALL BE ROTO-TWIST (OR APPROVED EQUAL) CABLE-TYPE OPERATOR. 4'-0" BELOW GRADE. .- r- In 1.0 d a ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 9O HANG AHU ALONG MEZZANINE CATWALK. AHU SHALL BE ACCESSIBLE FROM CATWALK. 16 DROP CHILLED WATER PIPING BELOW GRADE. 3O ROUTE 3/4" CONDENSATE DRAIN PIPE TO SINK TAILPIECE OF TOILET ROOM 1. PROVIDE Y-FITTING & 10 ROUTE 0/A SUPPLY DUCTWORK HIGH ABOVE AHU, COORDINATE DUCT ROUTING WITH WINDTUNNEL 17 CHILLED WATER PIPE SUPPORTS BY PHP OR APPROVED EQUAL, MANUFACTURER TO PROVIDE STRUCTURAL INSULATE HORIZONTAL DRAIN PIPING, SLOPE DRAIN PIPE DN AT 1/ 8" PER FOOT. REQUIREMENTS. ENGINEERING. • SHEET: 0 ALL EXHAUST DUCTWORK ON THE POSITIVE PRESSURE SIDE SHALL BE OF DOUBLE WALL CONSTRUCTION. 11 ROUTE REFRIGERANT PIPING TO ASSOCIATED AHU'S, REFRIGERANT PIPING SHALL NOT BE ROUTED OVER 18 COORDINATE LOCATION OF LOUVER WITHIN METAL PANELS OF BUILDING ENVELOPE TO AVOID CUTTING THE AREAS WITH EXPOSED CEILINGS. WHERE NECESSARY, REFRIGERANT PIPING SHALL BE ROUTED ON RIBS OF PANELS. ssoc�a es 5O PROVIDE CONDENSATE PUMP AS INDICATED ON SPLIT SYSTEM SCHEDULE (RE: M401) FOR FCU. WINDTUNNEL SIDE OF DIVIDING PARTITION, COORDINATE WITH WINDTUNNEL REQUIREMENTS. 19 3-WAY CONTROL VALVE, REFER TO CHILLED WATER PIPING SCHEMATIC FOR ADDITIONAL INFORMATION. AUTOMATIC DAMPER IS INTERNAL WITH LOUVER, REFER TO SCHEDULE. 12 REFRIGERANT PIPING UP TO LEVEL 2, REFER TO M202 FOR CONTINUATION. COI'1SUOting Engineers 20 ROUTE CONDENSATE DRAIN TO FLOOR SINK IN FIRE RISER RM, RE: P201 FOR FLOOR SINK LOCATION. 22 7O ROUTE 3/4" PUMPED CONDENSATE DRAIN PIPE TO SINK TAILPIECE OF TOILET ROOM 2. PROVIDE Y-FITTING 13 CONNECT TO OWNER INSTALLED HEAT EXCHANGER, VERIFY EXACT CONNECTION LOCATION WITH OWNER. 21 INSTALL CHILLED WATER PIPE HIGH TO ALLOW FOR CHILLER MAINTENANCE. 8217 Shoal Creek Blvd & INSULATE HORIZONTAL DRAIN PIPING. ROUTE PIPING TIGHT TO WINDTUNNEL SIDE OF DIVIDING PARTITION. 14 RETURN AIR TOWER OUTLINE BELOW GRADE. THERMOSTAT SHALL BE EQUAL TO HONEYWELL VISION PRO 8000, RE: SPLIT SYSTEM SCHEDULE NOTES FOR Suite 100 a M 2 m I ADDITIONAL INFORMATION. Austin, Texas 78757 23 PROVIDE SPOOL PIECE SUITABLE TO REPLACE WITH FUTURE AIR SEPARATOR, TACO 4900 SERIES OR 512-407-9011 EQUAL' 512-407-8287 (fax) . : .N . i . d ? i2.08 8 , .9 4. a6 T '4 f a G O �OR0 89617FE 9 % OREGON AMBER FKA4 08.2015 EXPIRES 06/30/2015 ; • r j � t t { ♦ mow.,.,-. � _I i ` ugam-rp a , f/~ ~~\ , jz_1 ._____^c^•, i'"_"_St� �,�>- .a.r .-.,.,a.-.....,m.....,-.mz .... ._.-.....:_...:+ ��_ i ., - ..�,,..�.... - - �r.. - 7 1 ... ;.._...-----•'----�.�___,-._,.._..__. -:! - tr » cam- _ --_ _ - - -- �;�,,;, ! .i t P'm O e_:._ ._ ______._—.____�..:.-_--'-_.--__...----._...._.__._.__.__..____r!'I.:•::.1�.a.�, iz.s f ti it -3AHU2 t1f i1i Ii t Ii I, Stair 3 f ...�- - _ i iI a,r WF-- •I i I �%1---- , 3 I itt, i j i j i f 1 � 1 i f t f I a 1 1 i f , � f ♦.. .•:,1^ I _ _ _ ! i _ V) I 1 � �: _ .__-'_-____..__._.___.—__-____ .._.._..._ �__._-1 i _ i,i 1 , ! I � I' a t j { I i { I i - �s ; i I !� �j. :;:!: ...-_-.-_.._--'--------_.___-.-'-__ :r•�-__ t.'.(.. !:j t' � 1r `l♦� +; i I:�: �� `,. —�I ;�..i; ;:�" l.!; E ! ± i I � €; i M ! j 1 ! 4 i .,f ; i ; I f f \: ;.: .:, .• ,/'� I..r.-;i.:• � ! ! r � Z — } I , �::' :�1 ; �'� _ �.§'y i i \ �3; j .t, —�— I i] J } "�- i:;'�.;:.•J .�:,i--�—...�._...._._....__.__._._-...--.1 �x { O i Lu un U , § !.. ) , y ,x :.. }.i -•-'�_ _ ---�17 �. '1 i _ _ `�'-+-sem--...._ �� i f:�r+..-•--•---..-•• - g t:::::; 7 t "_-_, ll : .. Stair 2 �....�..,:.. _�.,.,.�,�.�._. .: , . ; � s ..._ I ! ��'<-. 1 a 1 �� a'— - - — j ; j— ,. 33 I �.,' '4. Social Media ', I i ! ; �_ 1 ! :i I'� i ' O I- ! ' — • ! :�, ; it , ( j � ,tl I + ;: ( , � N 41 i '�\ t ! ! i f 1 a ; ! I i a t t ( ! t_! f i a < I- j e R A is 1 I Flight Controls i ; ; ! ��, ! i + ij ! i ! i i ' I I f u zE ! O 1 I , i ! •:.. , ' i ; ! 122"X22" { ' `` (� ! t ! �:` i i _• i( i ! ! I i i t:i':'. j Z = u , tt , F 1 1 I I 1 P. :sr'. M r Itandsi. _ _..._.._...�_ _. ,` Ii ! i i ? €::::_, i o `� 'ilN � �.:...._.—.----------a. - - - \• ! i i � f s € _ I— � , y �I V � I �[ ( I ! 219 _ ! �. � ( i. I ba I ><' t I a r ; ; CU 05 FII ht ha bei i —.—— ! a 1 1 I /� `. i mow.^_. t� \ i i € I i f 9 ! ,.,�.-.'.v.! y::�•.: ,: : - n: ! f� 'Y, ...^' a}d: ,'�s1C'. "aa \ t + {{ �f } Ln � 1 W E 405 , Staging � "s ./`� .' +brn. � t t::::;, ; ::.:•:;t) :: ! 12"!D ! y a! 1 E 400 k x 1 + ':•}:::•:!fi i§, i i. _ ..... .. . ,;1 � j I / J,- { ♦i1�y _ , � \ `12 i %1 1 1 i .` i „ i j :.:;:::;:a• 1 !::..•., -'- ---_- __.._._.._..... AHU2 3 _ _._.._.._-_ ___ "..___ + I \� 1 Ln ! €:;j;.::i:.l I f;}:is• - - , , : LLI i O o 1 t.t t t ,'i gxg T� �_ _ t r j aw .. ...•....`'__.M__% j —__"'� ; } •.a AD i I:t S T € �S t i f ` •1 k.r, �E^_1 ! - +" ; i is i t r i ra 1� a t ,; E 12651f 12„� i ; ;F { t i> ij”i ------. i ! ! ! I a f ♦\ i 1 i k G 1 N Q , Flight Chamber ; I; >:+ � +: t;' j �} !! :1 � p r I t ;!i I! •` I i', i ! + I 3/'4- I j i i i M L ! r'.1.'.'r� 1 + I>= :! i t•""'``. —f,F_ DRAWN: ,��:•: ( {: !� a , t f � i _.__._� "� •, + �`. if �'-�-. '---3 ( E 280 - - .. .. : ,ii '��) a ��'..i,' i ; � i 1` z•. j ( €s:j \ \..-...J` j �it ! { ! } + lti � e :;r l / �3 Gear U !!! t I:. >:i CHECKED: ( p ;i; I 'r, a 1 f p i l..B ! I •�\ r'S,: I ,'>; rr r ! ;! i i I!i #I �i;-1 E 265 € `. ,b a. , i '_ ;1 \,•.{, f/ I , _ ;a, ! ! :I 1 .,i:-'d':i } f i i � / 204 t :S '� ! t f�•. JOB NO: 1 3 1 4 1 i !':.1:::j•'1 { €.:<::::1 :+ r"' 12 0 �5- /' �± '\ !// / tu '(i I'.•:.. j S:.i:.::;, 1 1 ( I ''':f.:i ; ! j ! • . �+s s \\ r iIN, i ;l i i ;1 l ! f:.i• i j �.s.::s.1 i j'•` ,� i' i i f � i '` la ..�.,~r �I � ! � N I� !i a t jj ! i - -- ; , , I 1 4 ( 00 �r• I >f� , J1 'i 1 F i ..j:::.i !.� '.I 1 i i ;�' -rE d{'�.� � / ( 1 I'..:- '! I l:.;.•:': ) i t '.:1: I 1 i 1 :�.. I ! •:1 I I i € �.. r,.hl: .i� ,fFy i ///�.JJ t h i l i f ! 1 l':' + 1 : s. I !-t;.:t;1 i a -_.•._ t y. ! � 3 ;�..._.._.... ! -;-^,-- i _._. .� ! , (€; f; j s;.t•;.,;:, ! i ,�rx A 1256 1 00 r _._ TYP.(4) TYP. ( I i 12 i ! .. i ! 12Q UP TO LVL 3 1� J AD VIP TYP. "�Q ...I i a• ! i !. I I I ! ! G; 1 :'i [ I: { a ! ! RE: M203 � � 210 t oo -...0. 12"0 _.,_......_ � __�.�. _3_..T � - - f -�- --- _ `T__"'_''_. .?_tet_.'-i' , - �___._.... .___jJensen / Fey ;+ ;:jam--_.•-#-- .��.�.._ �>�� :7;! i `'i�.. 8 ♦ t 1 i 1 n. — 1 F Architecture and Planning , t f i f i f ! ! g , ! i t t , ! i , i 4 i i i b , 7730 LEARY WAY NE , r• ,y , a,..,.'! .. � ,; .�___ ,. •>.',,.� € s { ! t ! �"�^ `is -f ':I• -- -- - - _ _ ice ! j I i r _. v...-- � REDMOND WA 98052 , , AHU-2' : _ ,` TEL:425.216.0318 FAX:425 �, + .__.__.____-_--- - :--a3 - -- -,- - ---- - - - - --=•r,` - "_ . __-_ - =. i--'s�• --�+--� - - .216.0329 16/16 UP 0 LVL 3 ...., . t ,,. ,. ! 'l- •l. •>,.�:.. i" ,:.......1�U2.-2! --_� � `-a +- ♦ ,” •_EF -3 FROM LVL 1 i.;,.. t 9 : ,. - - _ -- __ -__ Laundry 3 MVD f r j RE: M201 M203 A 81D 0t. Stair 1 „_ I ! - DN TO ryn i ; 8" t _ GV� ` . 1 � LVL_1 ; ♦ '�,\ J '- - 8 � ,. ' 0 Elevator - _� ., I, „I♦, �, .♦ :; , ` __._ � � �__� ! ' - Lobb .• .�_---------'---- _ -�-- - ----- - _:-�.- - i;- 1 - 215 : l 2� 1.• _ , { , + ;-- r— -r—_—4—_ 14 14 a , TS AHU 12/12 +j i 14/14 A 550 i 4 14/14 , , i ! z , 1 s , a - - t , t : i AHU2- 5 i� ♦ 1 , — s' P �. a ,f : ,. .. �_..__..",_----- ---- --� i'-,'---•'�' � ,. ..-�, C -C''-, . ... r-' 'C--� ., _�--s- -tt---♦—c_,..[--r�..�.. ,...F_. �r..,���r.-..st.. �.F'�=»-�.c---•=...�— �__t..r _ _�..-- _ _ �.,s._ _ r �r € '..,...,.....•......-_.__.:..:_,•.-�.,..,.»...._.....dw.. _..,.,.. ._..t3 `t -c'--r---��'#''c.,_ �. .T .--'t �""'T` � -'� ` � '.t' _C" \ --=T--•c-=r•...--c---•'- - � "`�- - - �C-'�'- --"'=Y-- -in— i•3-r^-- '__'1 i G._ 135— ~-- G 135 G X35 1 G 135 G 135 — I Classroom + _ 4 ! „ f ! Toilet 2B Toilet 2A AHu2-� i jI �- i ) i 8"0 X80 i 80 z 4'-0"L. 4 -0"L. 4-0 L. 4'-0"L. 4'-0'L. 227 214 f i � 11 l ! '• I ! ! 1 if M rIJ I f i m S 3 J a , 1 1 F I 1 H r �.f O �{ MECHANICAL PLAN - LEVEL 2 O 1 Scale: 1/4"= 1'-0" - I— I KEYED NOTES: O DRYER EXHAUST CAP, MODEL SHALL BE SEIHO SFX OR EQUAL. � 0 rCS 2O SLOPE 3/4" CONDENSATE DRAIN DN AT 1/8" PER FOOT TO MOP SINK IN LAUNDRY ROOM, PROVIDE 1" AIRGAP AT SINK. > 3O ROUTE 0/A SUPPLY DUCTWORK HIGH AND TIGHT TO STRUCTURE SO THAT IT DOES NOT INTERFERE WITH V EQUIPMENT SERVICE CLEARANCE. m O ^ 0 SMOKE DETECTOR SHOWN FOR REFERENCE ONLY AND PROVIDED BY ELECTRICAL CONTRACTOR, REFER TO m ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. z U O ALL EXHAUST DUCTWORK ON THE POSITIVE PRESSURE SIDE SHALL BE OF DOUBLE WALL CONSTRUCTION. V) W 0 PROVIDE REMOTE DAMPER OPERATORS FOR ALL DAMPERS LOCATED ABOVE INACCESSIBLE CEILINGS. l.. > C� OPERATORS SHALL BE ROTO-TWIST (OR APPROVED EQUAL) CABLE-TYPE OPERATOR. O w V � � u CD o 7O ROUTE 3/4" CONDENSATE DRAIN PIPE TO SINK TAILPIECE OF VIP ROOM. PROVIDE Y-FITTING & INSULATE O b CD o r HORIZONTAL DRAIN PIPING, SLOPE DRAIN PIPE DN AT 1/ 8" PER FOOT. E °O O ROUTE REFRIGERANT PIPING TO ASSOCIATED AHU'S, REFRIGERANT PIPING SHALL NOT BE ROUTED OVER Lf1 U - AREAS WITH EXPOSED CEILINGS. " v t^ Lr) , ami h- i; N V 0 REFRIGERANT PIPING DOWN TO LEVEL 1 AND UP TO LEVEL 2 THROUGH REFRIGERANT PIPE CHASE AS (� >_ " SHOWN. O a m ^ o x mechanical - electrical - plumbing _k0 3 = 10 COORDINATE LOCATION OF LOUVER WITHIN METAL PANELS OF BUILDING ENVELOPE TO AVOID CUTTING THE •- �- In 1° Q a w RIBS OF PANELS. WHERE CUTTING INTO THE RIBS IS REQUIRED, THE CONTRACTOR SHALL CENTER THE . LOUVER BETWEEN THE TWO PANELS. — 11 REMOTE TEMPERATURE SENSOR EQUAL TO HONEYWELL TR21, RE: SPLIT SYSTEM SCHEDULE NOTES FOR . SHEET: ADDITIONAL INFORMATION. 12 REFER TO ARCHITECTURAL ELEVATION FOR LOCATION OF NOZZLE DIFFUSERS WITH TECTUM PANELS. ssoc es Consulting Engineers 8217 Shoal Creek Blvd Suite 100 M202 Austin, Texas 78757 512-407-9011 512-407-8287 (fax) ! 0 N 4 ;4 9 ( 4.2 �4:1 \` (3.5 ) , .4j ;: 12.5 ) � 2.1 ) 2.0a. . 896 7 E II �.i✓ OREGON .7 \ t rO ' ¢ ? 1 ! f i �' v0 GENRES O Q� t + < < 1 i ; 1 ; _ KAY 01.08.2015 EXPIRES 06/30/2015 Lw s /l , i i ' r'I - --- { 1 I° t i LU1 I g i fFF , r 14/12 :. :,.—_.,-;_...___�..�..._�._._ _ I , 1 y I... . Ln A... ._ . .... . .. . . , 9 ,L•... : :: I : MVD AHU3 3 - - - ....._ - ----.. _ _.. _ . ... .:... ..... TYP ! Stair 3 41 1~ t W I— ¢ i _ , :.r 306 =— — -- I'n � .�; t ::D 32"114 _ --_ _ - - i f I .y f. S 0 4� P EDH3 3 1 { ji ¢ { / ! i 1 s ! i I // ¢i �• �- zSl — j� 1 v ! ! i ,� ' .i i ! I— Z R , I1 Z U 61 j !, I I:F:?• 1 ' ,:-.�.: , :; ; ' t i i i } F,.....,,,d i 1`' t i } '3 1 V) W V) Z 9 I -. � _ U W L i � t l't I' -i i ! \ I - '•i 1 i , i i ��. ,. i �j�h`t t A 50 j i ..,�� t I "I '�t � � ! ,` `----•-_..__..._.__-7.- -., �. \\� '.:r� y, ' { I '#�'i_-�I � 1. .� Server Rm .\ � 3 1 - Ln r:? ¢ t f, ¢ \ 308 { / 'i �._.__ __. \ iso _ `. i ; , �! } { o 0 i i ., i� t 12/10 n- w , < I I c 1 1 Men EF 2 I ! r — I , ( —) — �� �41iU3-4 �\ ; i z d 1 / TYP. A 1= k A i I \ ! , t 1 I \ I w 31 6 I :; ` � - -- r 1 # `, 3 4 -= ' mil i s — TYP. `5 t i i ¢ :; i o 0 4 / -- —._ ¢ ,/Team Rm 1 _ `,� T A ,400 'IT.� a ¢ --- _. C0 .. :: � tl \ { ��'r �� _ _. .___._._. .._..__._ _ __,i i_ gg�,-*� _.-...._.._..____..__-___-._'____..._.-. ..-_•_-___•__._...__-_.__..._—_ ._.._..f.._..�_.___t....-,...___^j_.. ..._..__.______•__.._..._...«........__ C i _....�...� ...�� ..,� ' f.. _�- j ._' G 100 1 i �..., , ( \ ♦., \ Hall 2 i 1 I 12/;1 , I I• i t 1 ; ¢ fy "=,Q 1± 310 M —.• DRAWN- L t 4 ¢ � s ! 1 + ; a i 5 I i I I ¢ l : 1 ¢ \� _ Break Rm _.. , A i i �� i f 1 w ! f I .� ¢ , CHECKED: CB Flex Rm 2 j I ,I i<: : SSI I : ..:� , �' , , � �( ( , Women { �D /TYP. JOB NO: 1 314 2 i' » f I, , _�:.., i •' 317 t� ;, , � ,i �_s ,; _ 1 i i j I. t�_��i i ,' ' ♦ t � 312 ,.-]1 �� #!' A 100 A 100 s - ; t m <- ¢,± y 1 1 . : __. ..�! ... - .♦� C. �� ,3.. , _ . i. ` \0 w✓ i .. 1 I Z; ,<� 'r , �: �` � J 1 ; \..-.s+• L,�-:.:� I l i ' � i _ 4 , ! ±td 11 j %� ¢ j 1 �5 I {{ I } I a ria x C , { 'I t `€-' % '. '.a ± \. ;,( �- ♦ �•• ^rye,. , I :0yL G} 1 fJ ! $ 1 is 1^ I Office , ( } _ t 1' ! ( , n'R Sr 'I 8 � � I i : 6 I ± . ► ' i !` - _____ _ __ _._— 319 i ; I I I t t t 1 I I T 14 1 ¢ ! ' I i — t i 1:' ,! i ! f-- '� __.y _ / -- — — I i i I P: art' 17 i-- .�.}— ... s•�� Y' P -i- '_'... � ..-. -, ..._ ... _ .. _ _... 1..({,. .__.,.._. ', ._._. _ ._.._. _ ._._._._ _._— __.._. .._..__,-. - C@S.m,smm53-- _._ — ._.-._...— ..t._ __.._....._'— --_— ___._._.._. .__.._....._.__.�_ - _ - __ _— - ^Y:I.':-:.".vl�f:-.:....�:�rm-,:^.�__.--=-3a.� — __—'__-'_ —�. _ : t. ... --.2-,-, ..•...•-,-}--:-,s,-.-..->.-"--,-..,..-. r.. .— `i -. .._.._._.. , r : „a„��m:.:�,,. ...�,�.,.�.�_.,..,-..,.... ,..,a.... _ ...A.e.,...�,.A,.�.m,...mm * Jensen / Fey i 1 ! 7 k :ir'� �3._2 � _- - ”' � •' � , Architecture and Planning i .-:`=�• <�..________�— _.. __. �—•-�—! !A�'_______,.. i _ _ ll , ;r._.... __._____ —.--•-------------��'r—�•--=�. t 7730 LEARY WAY NE RE --__ : 1M2202 1 A ' :_.__... _ _ I ' REDMOND WA 2 � t ni ti, 'i_.... �. �. ���_ !. i�-"r..� 9805 / d 4 D1t TEL:42 5.216.0318 FAX:425.216.0329 8"0 , ;; I IN Al -8!0 AD s .. 4 .. _._-... i .,.._.__. .... .. _.. .. .__.,. .... .- I' ; •--j----tet_ ` ? i N B 1 EDH3-1•iiIk.- _.. - .:^r ,,.,...,..<. ....a.,R,:.,*..r...u..,e., ,; ., .a.m ._.t_ 1 _P._k..s_-'=--_ ___ -- ___- —___ -__ __ •t— — - N. — 2/1 Lobb !I -Manager .Elevator 303 I i '.320 Aliu3-1 ¢ _ , CEO i E i titU4 I I1 302 r A 2fi0 TYP.(5) Patio ¢ I - ) j ¢ I rte----a•^��Vit�"�... \ SYS. �, I it II _ - - _ ',i�1 I { E t } Y 313 1 . -,_.____--- ,_—_.— _—_—__`_"__ _-„-T -c, _r......•—,�_-_, "t.- -._—_._. _ -.__-.___.-`"__ .2- _„�:_-i_..,....^ -..._:._�;__:...`mac: _ -___-____-- _ _ _—__-- __— _ _ . :.- ._...__ -_.-___• ,_._. ___-'--_'- `__ _... :cr:..._ter_._ mss•-._..... ._..�._.... J _ ��,�,�i.•j:.p,�,»���„i �i�,s•aA�*:.,:�::Q>:•+�•,a. __-3•— ,-'- -'^___'e --et__'�•c—:.t�:,a'>g�,,.,...�:.<,t-,.r�rv�;K:7v�,,,._,u•R,....,,��.,-> _ ,_'�, _ _t—' \ � � •� .. —�- --=-= ,a�"�=_=:-�-_—� G 175 1 G 1175 ¢ i ¢ M ' ! t a� m oC O KEYED NOTES: _0 N O MECHANICAL PLAN - LEVEL 3 O SMOKE DETECTOR SHOWN FOR REFERENCE ONLY AND PROVIDED BY ELECTRICAL CONTRACTOR, REFER TO J c Scale: 1/4"= 1'-0” ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. - 2O ALL EXHAUST DUCTWORK ON THE POSITIVE PRESSURE SIDE SHALL BE OF DOUBLE WALL CONSTRUCTION. w 3O ROUTE 3/4" CONDENSATE DRAIN PIPE TO SINK TAILPIECE OF CEO 302. PROVIDE Y-FITTING & INSULATE 0 HORIZONTAL DRAIN PIPING, SLOPE DRAIN PIPE DN AT 1/ 8" PER FOOT. 4O ROUTE 3/4" CONDENSATE DRAIN PIPE TO SINK TAILPIECE OF BREAK ROOM. PROVIDE Y-FITTING & 0 INSULATE HORIZONTAL DRAIN PIPING, SLOPE DRAIN PIPE DN AT 1/ 8" PER FOOT. ■— 0� IZ O 3/4" CONDENSATE DRAIN FROM AHU4-1 ON SERVICE DECK. ROUTE TO SINK TAILPIECE OF TOILET 4. .> U L PROVIDE Y-FITTING & INSULATE HORIZONTAL DRAIN PIPING, SLOPE DRAIN PIPE DN AT 1/ 8" PER FOOT. p[ O ` 0 AIR DEVICES WITH SPIN-IN DAMPERS LOCATED ABOVE IN-ACCESSIBLE CEILINGS SMALL BE PROVIDED WITH 0CABLE TYPE REMOTE DAMPER OPERATORS. m rn w 7O REFRIGERANT PIPING UP TO SERVICE LEVEL, REFER TO M204 FOR CONTINUATION. Un z v W v, _ 8O ROUTE REFRIGERANT PIPING TO ASSOCIATED AHU'S, REFRIGERANT PIPING SHALL NOT BE ROUTED OVER L_ W U v AREAS WITH EXPOSED CEILINGS. O � N o V O ROUTE REFRIGERANT PIPING DOWN TO LEVEL 2 IN PIPE CHASE AS SHOWN. O u -2 oM o ■� �w rtf w r,4 to 10 ROUTE REFRIGERANT PIPING DOWN TO LEVEL 2 THROUGH REFRIGERANT PIPE CHASE AS NOTED BY KEYED > >,� (n 110 NOTE 9. REFRIGERANT PIPING SHALL NOT BE ROUTED OVER AREAS WITH EXPOSED CEILINGS. V) o � 4 IS 11 ROUTE 3/4" CONDENSATE DRAIN PIPE TO SINK TAILPIECE IN RESTROOM. PROVIDE Y-FITTING & INSULATE a, "' V HORIZONTAL DRAIN PIPING, SLOPE DRAIN PIPE DN AT 1/8" PER FOOT. rL.r1 v ~ `^ N 12 CONDENSATE DRAIN PIPING FROM AHU3-4 SHALL BE CONNECTED TO THE TOP OF THE SLOPED DRAIN O u `'• LINE TO PREVENT BACKFLOW. mechanical - electrical - plumbing Lj- Y o = r r— v} to d o- LL 13 COORDINATE LOCATION OF LOUVER WITHIN METAL PANELS OF BUILDING ENVELOPE TO AVOID CUTTING THE RIBS OF PANELS. WHERE CUTTING INTO THE RIBS IS REQUIRED, THE CONTRACTOR SHALL CENTER THE — LOUVER BETWEEN THE TWO PANELS. SHEET: 14 22"02" INTERNALLY LINED RETURN AIR ELBOW (1", 3# DENSITY ACOUSTICAL INSULATION.) ssoca es Consulting Engineers 8217 Shoal Creek Blvd Suite 100 M2m3 Austin, Texas 78757 512-407-9011 512-407-8287 (fax) i d' 04.0 ; 0 D PROFFs O 2 ALARM SIGNAL TO TRANE MECHANICAL GENERAL NOTES: �c•�w�c,T Ne 6„ / CHW SYSTEM L 89617FE IP 1. CHILLED WATER SYSTEM WORKING PRESSURE = 125 PSIG. 2 OR, );GON , 2. HEAT TRACE AND INSULATE ALL CHILLED WATER PIPING EXPOSED TO THE OUTDOORS v OLF >g?� INCLUDING PUMPS, VALVES, STRAINERS, FITTINGS. HEAT TRACE SHALL BE 208V/1 P. Oq 8ER �P T - KAY ;,C}8.2015 1 CH-1 \11� 4-20mA COMMUNICATION SIGNAL TO FS 2 EXPIRES 06/30/2015KEYED NOTES: TRANE CHW SYSTEM 1-1/2" MAKE-UP 6" 2 ___ RE: PLUMBING T11 1-1/2" 6�>TYP• O1 BASKET TYPE STRAINER. (� COMMUNICATION SIGNAL TO 10 sSI RV O2 AUTOMATIC AIR VENT, SEE DETAIL. CHWP-1 - ' OWNER'S WIND TUNNEL PLC 5 4 CONTROL SYSTEM. HMS AND Inu)M O3 NON-SLAM SPRING OPERATED CHECK VALVE. TYP. TYP. I / CHILLER SYSTEMS MUST BE 4O PRESSSURE GAUGE WITH GAGE COOK. >,(D ABLE TO UPLOAD SELECTED CT-1 S 8 � / _ TYP. DATA POINTS TO A SQL SERVER O5 BUTTERFLY VALVE 1 PROVIDED BY SKYVENTURE WITH 6 FLOW METER w AT LEAST A 3 DAY BUFFER O N ERIOD. COMPRESSION 7 1-1/2" MANUAL DRAIN VALVE z TANK O 0 \ 3 / SEE DETAIL O FLOW SWITCH w F- un U �� O9 CURRENT TRANSFORMER ON ELECTRICAL POWER CONNECTION TO VFD. z Z CHILLER 1 10 INSTALL WATERPROOF LINK-SEAL WALL PENETRATION AS HIGH AS POSSIBLE. O N PROVIDE BLIND FLANGE AT CONTROL COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. U z FUTURE CONNECTION TO PANEL ROLL UP CHILLER 11 TRANSITION FROM UNDERGROUND STEEL TO SCHEDULE 40 PVC PIPE. o Z) OU I- 0 12 Uj FLANGED CONNECTION FOR TRANSITION FROM ABOVE GRADE TO UNDERGROUND PIPING. Z N 6" u O > 13 THERMOWELL WITH OMEGA #PR-18-2-100-1/4-4-E TEMPERATURE SENSOR AND w U w OMEGA #TX92A-1-L TRANSMITTER. 6" 14 6" 12-1200 GPM OMEGA #FTB760 INLINE FLOWMETER WITH OMEGA #FTB700-T Ln TRANSMITTER. Uj 0 0 15 CONNECT TO OWNER FURNISHED AND INSTALLED HEAT EXCHANGER. N N Q 00 N 1" 3-WAY CONTROL 16 VALVE NOT USED. r 17 ISOLATION VALVES SHALL BE LOCATED WITHIN CHILLER YARD. 0 0 CHEMICAL 18 0-100 PSI PRESSURE SENSOR, OMEGA #PX309-100GI. POT FEEDER Q r N T 6" 4-20mA C UNICA N SIG TO M DRAWN: J M L TRANE CHW SYSTEM CHECKED: Cg 2 I SOB NO: 1314 2 4-2OmA COMMUNICATION SIGNAL TO TRANE CHW SYSTEM 2 6" 6" 6" .Jensen / Fey pip Architecture and Planning 7730 LEARY WAY NE 1 1 REDMOND, WA 98052 11 TEL:425.216.0318 FAX:425.216.0329 10 1O 18 18 1212 13 ������%�������,\\/ CHILLED WATER PIPING SCHEMATIC �'� ,�'/%�'� ~ 13 14 SCALE: NOT TO SCALE 14 SCHEDULE 40 PVC SCHEDULE 40 PVC ` WITHIN TURN POCKET WITHIN TURN POCKET/= 4-2OmA COMMUNICATION SIGNAL TO 4-2OmA COMMUNICATION SIGNAL TO - .; CONTROL OWNER'S - _ - - -� —5 OWNER'S WIND TUNNEL PLC WIND TUNNEL PLC CONTROL � -•--�'""- �- SYSTEM (TYPICAL OF EACH SYSTEM (TYPICAL OF EACH O TEMPERATURE/PRESSURE SENSOR AND TEMPERATURE/PRESSURE SENSOR AND - - - —'` ig .V OWNER FURNISHED AND INSTALLED 15 3/4" FULL PORT - —�' FLOWMETER) ) FLOWMETER OWNER FURNISHED AND INSTALLED RAT HEAT EXCHANGER AND PIPING BALL VALVE RAT HEAT EXCHANGER AND PIPING E COMPRESSION TANK SCHEDULE SCHEDULE OF AIR COOLED WATER CHILLING UNITS M N V EXPANDED COOLING CAPACITIES N Ln TANK LENGTH WATER CAPACITY 9 UNIT DESIGNATION EVAPORATOR AMBIENT AIR MARK LOCATION SERVICE POSITION TYPE DIAMETER (IN) MANUFACTURER AND MODEL NUMBER GALLONS }-� MINIMUM TOTAL CHILLED CHILLED WATER TEMPERATURE CHILLED WATER TEMPERATURE EVAPORATOR MAXIMUM MCA MAXIMUM FUSE SIZE MIN. v f GALLONS WATER FLOW- ' MAXIMUM PRESSURE TEMPERATURE REFRIGERANT NOTES / REMARKS (IN) 2 CAPACITIES TONS G ENTERING EACH EVAPORATOR - 'F LEAVING EACH EVAPORATOR - F FOULING FACTOR OP MAX •F 460 V A 4fi0 V EER/NPLV 0� CT-1 CHILLER YARD CHILLED WATER VERTICAL DIAPHRAGM 24 43.875 34.0 68.0 BELL & GOSSETT D-120V (OR EQUAL) CH-1 163.5 875 44 40 .00010 39.6 95/0 HFC-134a 358.0 450.0 TRANE RTAC170 10.6/15.1 �_ •Q L_ NOTES: 1. RELIEF VALVE SETTING SHALL BE 100 PSIG, PRV SETTING SHALL BE 10 PSIG NOTES: � 1. PROVIDE THE FOLLOWING OPTIONS: PARTIAL HEAT RECOVERY WITH FAN CONTROL, ADAPTIVE CONTROL MICROPROCESSOR, Y-DELTA CLOSED TRANSITION STARTER, LOW AMBIENT CONDENSER FAN SPEED CONTROL, EVAPORATOR FREEZE PROTECTION, REMOTE DISPLAY PANEL, CONDENSER COIL HAIL GUARDS, CONTROL POWER TRANSFORMER, NON-FUSED <C DISCONNECT SWITCH, 15 AMP GFCI OUTLET CHILLER SEQUENCING CONTROLLER, CHILLER ALARM OUTPUT CONTACTOR, POWER FACOTR CORRECTION CAPACITOR. VFD SCHEDULE 2. CHILLERS SHALL HAVE MINIMUM COMPRESSOR TIMERS THAT ALLOW 5 MINUTES BETWEEN STARTS, AND 3 MINUTES BETWEEN STOP TO START. a '> UNIT 3. WHERE SPECIFICATIONS ARE MET, ALTERNATE MANUFACTURERS ARE: CARRIER, MCQUAY, YORK. U SERVED SERVICE MOTOR VOLTS / PH / HZ 2 SEP CHWP-1 SECONDARY CHILLED WATER PUMP 30.0 460/3/60 U PUMP SCHEDULE o r°C, i M O r-,-,. 1,. rN to ELECTRICAL DATA t� 61 0 FLOW T.D.H. RPM EFF. Ln ^ I NOTES: MARK LOCATION SERVICE TYPE, SIZE GPM FT WG (y.) MAX MANUFACTURER AND MODEL NUMBER u'1 U HP -VOLTS H 2 a- Ltl N to N V 1. VARIABLE FREQUENCY DRIVES SHALL BE PROVIDED AND INSTALLED v BY DIVISION 15. CHWP-1 CHILLER YARD CHILLED WATER END SUCTION, FLEXIBLE COUPLED 875 90 1750 84 30.0 460 3 BELL & GOSSETT e-1510, SIZE 5EB , M o x mechanical - electrical - plumbing LL C 3 -= r v» Qdu- SHEET: NOTES: ssocia es 1, MOTORS FOR OUTDOOR PUMPS SHALL BE TEFC RATED. Consulting Engineers 8217 Shoal Creek Blvd M 31 Suite 100 ° Austin, Texas 78757 512-407-9011 512-407-8287 (fax) i N 'QPRO O �G I N F.61 { � 8961i7VE�� ]� 14 V OREGONL `Lo FMeEIS�a'�P� �E 11 EXPIRES 06/30/2015 2 14 6" X 1" i 1 SADDLE 12 6" SOC X SOC SCHED. 6" SOC X SOC SCHED. w 40 PVC COUPLING 60" 30" 40 PVC COUPLING LU � v LU 6" SCHED. 40 1" SCHED. 40 —� 6" SCHED. 40 13 15 z � PVC PIPE PVC PIPE F1PVC PIPE 0 F- 1" SOC X 1" U 0 THREAD CONNECTION Z U 3 g ♦- p 1" FULL PORT ---- 1 y ,t, \ -� z V) BALL VALVE \\ 4 ) � U w 10 u o U 3 ONICON F-1210 W O O FLOW METERQ N N 0 00 N 5 �( 6 ) 00 < N a 1 FLOWMETER ASSEMBLY Scale: NONE U DRAWN: JIVIL (� CHECKED: CB JOB NO: 1 314 15 1 TRANSMITTER,RTD,-40C-60C (OMEGA#TX92A-1-L) 14 2 COUPLING,SOC X SOC,6"SCHED.40(SPEARS#429-060) PVC 13 1 RTD PROBE(OMEGA#PR-18-2-100-1/4-4-E) SS 304 12 1 THERMOWELL, 114"DIA.ELEMENT,4"STEM, 1/2"NPT(OMEGA#1/2-260S-U21/2-304SS) SS 304 1 1 1 SADDLE,6"X 1/2"(SINGLE-SRF-EPDM-SS,SPEARS#467SE-523SR) PVC,EPDM,SS 10 1 RESSURE TRANSDUCER,0-100 PSI,CABLE CONNECTION(OMEGA 1iPX309-100G1) SS 304 9 1 REDUCER,3/4 SPIG X 1/4 FIPT SCHED.40(SPEARS#438-098) PVC 8 1 IOSE,3/4"ID,ECONOMY GARDEN X 50' (MCMASTER-CARR#7454T22) VINYL 7 1 ADAPTER,MALE PIPE THREAD TO MALE HOSE(MCMASTER-CARR#73605T92) BRIGHT BRASS Jensen / Fey KEYED NOTES: 6 1 ADAPTER,3/4 SPIG TO 3/4 FIPT SCHED.40(SPEARS#478-007) PVC 5 2 VALVE,BALL,COMPACT 2000 SOC-VITON (SPEARS#6632-007) PVC Architecture and Planning 8 FLOWMETER ASSEMBLY, SEE DETAIL 4 1 TEE,SOC X SOC X SOC,3/4"SCHED.40(SPEARS#401-007) PVC 7730 LEARY WAY NE 9 TEMPERATURE—PRESSURE SENSOR ASSEMBLY, SEE DETAIL 3 A/R PIPE,3/4"SCHED.40 PVC REDMOND, WA 98052 2 1 SADDLE,6"X 3/4"(SINGLE-SOC-EPDM-SS,SPEARS#466SE-524) PVC,EPDM,SS TEL:42 5.216.0318 FAX:425.216.0329 f- OWNER PROVIDED AND 1 A/RIPE,6"SCHED.40 PVC INSTALLED HEAT EXCHANGER ITEM NO. QTY. PART NUMBER DESCRIPTION MATERIAL GRADE BILL OF MATERIALS CONTRACTOR PROVIDED AND INSTALLED PVC PIPING TEMPERATURE-PRESSURE SENSOR ASSEMBLY _......._.___._..._..._.............. ._.--_............... ........................------- Scale: ._.Scale: NONE s M 4—J� -� 9 rn (3) O - o u p w -- -� o� tU CO W 3 Y O OWNER PROVIDED HEAT EXCHANGER (VANE BANK) INSTALLATION w u Scale: NONE -- i U V �M o -200 m O N rtf (� N tf1 I➢ V) > 0 v > � l.rl U X x ni m _0 O Lm 0 mechanical - electrical - plumbing V-- -Y o =5 -� viLDadu_ l� • • SHEET: seeds es IS Consulting Engineers 8217 Shoal Creek Blvd Suite 100 M3m2 Austin, Texas 78757 512-407-9011 512-407-8287 (fax) 0 N � F o w L� 89617PE r� r ��aZ OREGON a OL 20 �O ER�$' P= KA`l 1.08.2015 EXPIRES 06/30/2015 SPLIT SYSTEM UNIT SCHEDULE (R-410a ONLY) F7 LU EVAPORATOR TOTAL OUTSIDE EXT. S.P. GROSS COOLING CAPACITY DATA ELECTRIC HEAT DATA EVAPORATOR ELECTRICAL DATA EVAPORATOR MANUFACTURER AIR COOLED OUTDOOR CONDENSER ELECTRICAL DATA MINIMUM v)SERVES POSITION AIRFLOW AIRFLOW ENTERING AIR MIN MIN HEATING MINIMUM RECOMMENDED WEIGHT CONDENSER AMBIENT MINIMUM CONDENSER MANUFACTURER S(EER) WEIGHT zBRANCH PROTECTION REFRIGERANT O MARK CFM CFM DROP IN. SENSIBLE TOTAL CAPACITY STAGES VOLTS PH HP VOLTS PH CIRCUIT OVERCURRENT AND MODEL NUMBER LBS. VOLTS PH AND MODEL NUMBER RATING LBS. MBH MBH MARK TEMP. 'F CIRCUIT RATING A ARI `W V F DB 'F WB KW AMPACITY PROTECTION AMPACRY AHU1-1 SEE PLANS HORIZONTAL 2000 175 0.5 78.0 65.0 37.8 43.6 --- --- --- --- 1 208 1 10 15 TRANE TAM4AOC60 159 CU1-1 105 208 3 21 35 R410A TRANE 4TTA3060 (NOMINAL 5T) 13.0 226 ZO H AHU1-2 SEE PLANS HORIZONTAL 800 75 0.5 78.0 65.0 15.4 23.2 5.76 1 208 1 1/4 208 1 36 40 TRANE TAM4AOA24 116 CU1-2 105 208 1 12 20 R410A TRANE 4TTB3024 (NOMINAL 2T) 13.0 169 U z AHU1-3 SEE PLANS HORIZONTAL 2000 --- 0.5 80.0 67.0 43.3 57.4 --- --- --- --- 1 208 1 26.4 30 TRANE TAM4AOC60 159 CU1-3 105 208 3 21 35 R410A TRANE 4TTA3060 (NOMINAL 5T) 13.0 226 Z Z) O 0 AHU1-4 SEE PLANS HORIZONTAL 2000 --- 0.5 80.0 67.0 43.3 57.4 --- --- --- --- 1 208 1 10 15 TRANE TAM4AOC60 159 CU1-4 105 208 3 21 35 R410A TRANE 4TTA3060 (NOMINAL 5T) 13.0 226 ,) LU Z v) O > N uW LU AHU2-1 SEE PLANS HORIZONTAL 800 85 0.5 78.0 65.0 14.8 24.3 5.76 1 208 1 1/4 208 1 36 40 TRANE TAM4AOA24 116 CU2-1 105 208 1 12 20 R410A TRANE 4TTB3024 (NOMINAL 2T) 13.0 169 0 ce AHU2-2 SEE PLANS HORIZONTAL 1200 130 0.5 78.0 65.0 24.4 32.2 5.76 1 208 1 1/2 208 1 38 40 TRANE TAM4AOA36 120 CU2-2 105 208 1 18 30 R410A TRANE 4TTB3036 (NOMINAL 3T) 13.0 190 L^ r- AHU2-3 SEE PLANS HORIZONTAL 1200 130 0.5 78.0 65.0 24.4 32.2 5.76 1 208 1 1/2 208 1 38 40 TRANE TAM4A0A36 120 CU2-3 105 208 1 18 30 R410A TRANE 4TTB3036 (NOMINAL 3T) 13.0 190 0 0 w N N Q AHU2-4 SEE PLANS HORIZONTAL 1000 120 0.5 78.0 65.0 18.9 27.8 5.76 1 208 1 1/3 208 1 37 40 TRANE TAM4AOA30 117 CU2-4 105 208 1 15 25 R410A TRANE 4TTB303O (NOMINAL 2.5T) 13.0 173 0 00 N 00 AHU2-5 SEE PLANS HORIZONTAL 1000 --- 0.5 78.0 65.0 19.6 24.5 7.2 1 208 1 1/3 208 1 45 45 TRANE TAM4A0A30 117 CU2-5 105 208 1 15 25 R410A TRANE 4TTB3030 (NOMINAL 2.5T) 13.0 173 CD 0 AHU3-1 SEE PLANS HORIZONTAL 1300 120 0.5 78.0 65.0 27.5 35.9 --- --- --- --- 1/2 208 1 3 15 TRANE TAM4AOB42 133 CU3-1 105 208 3 18 30 R410A TRANE 4TTB3042 (NOMINAL 3.5T) 13.0 196 < N AHU3-2 SEE PLANS HORIZONTAL 720 50 0.5 78.0 65.0 13.7 16.1 7.2 1 208 1 1/4 208 1 45 45 TRANE TAM4AOA24 116 CU3-2 105 208 1 12 20 R410A TRANE 4TTB3024 (NOMINAL 2T) 13.0 169 AHU3-3 SEE PLANS HORIZONTAL 1600 170 0.5 78.0 65.0 32.5 38.7 10.8 1 208 3 1/2 208 3 41 45 TRANE TAM4AOC48 159 CU3-3 105 208 3 18 30 R410A TRANE 4TTA3048 (NOMINAL 4T) 13.0 226 DRAWN: JML NOTES: CHECKED: CB 1. FAN COIL UNITS SHALL BE VERTICAL CONFIGURATION, FLEXIBLE INLET & OUTLET DUCT CONNECTIONS, VIBRATION ISOLATION KIT, SINGLE POINT ELECTRICAL CONNECTION, FREEZE STAT, AUXILIARY DRAIN PAN WITH FLOAT SWITCH WIRED TO DE-ENERGIZE UNIT UPON RISE OF WATER IN PAN, AND 1- THICK PLEATED MEDIA (MERV 7 MINIMUM) FILTERS. 10B NO: 1314 2. CONDENSING UNITS SHALL BE PROVIDED WITH LOW-AMBIENT CONTROLS AND EVAPORATOR DEFROST CONTROL AS REQUIRED TO ALLOW OPERATION DOWN TO -10'F AMBIENT, ANTI-SHORT CYCLE RELAY, TIMED-OFF CONTROL, HAIL GUARDS, AND 5-YEAR COMPRESSOR WARRANTY. THE CONTRACTOR SHALL DETERMINE EXACT LENGTHS OF REFRIGERANT LINES REQUIRED AND SUBMIT TO MANUFACTURER FOR SIZING OF REFRIGERANT PIPE SIZING. PROVIDE ADDITIONAL COMPONENTS AS RECOMMENDED BY UNIT MANUFACTURER FOR PROPER OPERATION OF UNITS. THE CONTRACTOR SHALL INSTALL THE UNITS AND THE REFRIGERANT PIPING PER THE MANUFACTURER'S RECOMMEND INSTALLATION INSTRUCTIONS. 3. PROVIDE 7-DAY PROGRAMMABLE THERMOSTAT WITH AUTOMATIC CHANGE-OVER, HONEYWELL VISION PRO-8000 ELECTRONIC PROGRAMMABLE THERMOSTAT OR EQUAL. THERMOSTAT SHALL HAVE LARGE BACKLIT TOUCHSCREEN, BATTERY BACKUP TO RETAIN PROGRAMMING DURING POWER OUTAGE. THERMOSTAT SHALL AUTOMATICALLY RESET TIME SCHEDULES FOR DAYLIGHT SAVINGS TIME. SUPPORT FOR MULTIPLE STAGE HEATING/COOLING (AS REQUIRED), ADJUSTABLE PARTIAL OR FULL KEYPAD LOCKOUT, 5-YEAR WARRANTY. 4. DISCONNECT SWITCH SHALL NOT BE UNIT MOUNTED AND SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 5. BASIS OF DESIGN IS TRANE. IF THE ABOVE PERFORMANCE AND SPECIFICATIONS ARE MET, THEN ALTERNATE MANUFACTURERS (SUBMITTAL REQUIRED) ARE: AMERICAN STANDARD, CARRIER, AND LENNOX. 6. PROVIDE A CONDENSATE PUMP FOR AHU'S AS NOTED ON THE DRAWINGS: LITTLE GIANT VCC-20ULS OR EQUAL, 120V-1PH. COORDINATE WITH ELECTRICAL. 7, PROVIDE AHU2-5 WITH THERMOSTAT EQUAL TO HONEYWELL VISION PRO 8000 WITH A REMOTE TEMPERATURE SENSOR EQUAL TO HONEYWELL TR21. THERMOSTAT AND REMOTE SENSOR SHALL PROVIDE TEMPERATURE AVERAGING OR WEIGHTED AVERAGE BY SENSOR LOCATION AND PROGRAM TIME. THERMOSTAT AND REMOTE SENSOR IN EACH VESTIBULE SHALL BE WEIGHTED 50%. Jensen / Fey Architecture and Planning 7730 LEARY WAY NE SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE (R-410a ONLY) REDMOND, WA 98052 TEL:425.216.0318 FAX:425.216.0329 EVAPORATOR COOLING CAPACITY DATA EVAPORATOR ELECTRICAL DATA EVAPORATOR MANUFACTURER EVAPORATOR OUTDOOR CONDENSER ELECTRICAL DATA CONDENSER MANUFACTURER TOTAL OUTSIDE EXT. S.P. MINIMUM MINIMUM MINIMUM WEIGHT SERVES POSITION AIRFLOW AIRFLOW ENTERING AIR MINIMUM RECOMMENDED HEAT PUMP AMBIENT MINIMUM CONDENSER S(EER) BRANCH PROTECTION MARK CFM CFM DROP IN. TOTAL SENSIBLE HP VOLTS PH CIRCUIT OVERCURRENT AND MODEL NUMBER (LBS,) MARK TEMP. 'F VOLTS PH CIRCUIT RATING AND MODEL NUMBER WEIGHT ®TING ARI F DB 'F WB MBH MBH AMPACITY PROTECTION AMPACITY (LBS.) AHU4-1 SEE PLANS VERTICAL 1 3000 --- 0.50 85.0 1 70.7 78.9 78.9 1 5 460 3 3.1 15 TRANE TWE09OD4 325 HP4-1 105 460 3 17.9 25 TRANE TWA090D4 340 11.0 NOTES: 1• ALL FAN COIL UNITS SHALL BE HORIZONTAL CONFIGURATION PROVIDED WITH SINGLE POINT ELECTRICAL CONNECTION, AUXILIARY DRAIN PAN WITH FLOAT SWITCH WIRED TO DE-ENERGIZE UNIT UPON RISE OF WATER IN PAN, AND 1" THICK PLEATED MEDIA (MERV 7 MINIMUM) FILTERS. 2. ALL CONDENSING UNITS SHALL BE PROVIDED WITH LOW-AMBIENT CONTROLS AND EVAPORATOR DEFROST CONTROL AS REQUIRED TO ALLOW OPERATION DOWN TO -10-F AMBIENT, ANTI-SHORT CYCLE RELAY, REVERSING VALVE, TIMED-OFF CONTROL, HAIL GUARDS, AND A MINIMUM 5-YEAR COMPRESSOR WARRANTY. THE CONTRACTOR SHALL DETERMINE EXACT LENGTHS OF REFRIGERANT LINES REQUIRED AND SUBMIT TO MANUFACTURER FOR CERTIFICATION OF REFRIGERANT PIPE SIZING. INSTALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS. PROVIDE ADDITIONAL COMPONENTS AS RECOMMENDED BY UNIT MANUFACTURER FOR PROPER OPERATION OF UNITS. THE CONTRACTOR SHALL INSTALL THE UNITS AND THE REFRIGERANT PIPING PER THE MANUFACTURER'S RECOMMEND INSTALLATION INSTRUCTIONS. 3. PROVIDE 7-DAY PROGRAMMABLE THERMOSTAT WITH AUTOMATIC CHANGE-OVER, HONEYWELL VISION PRO-8000 ELECTRONIC PROGRAMMABLE THERMOSTAT OR EQUAL. THERMOSTAT SHALL HAVE LARGE BACKLIT TOUCHSCREEN, BATTERY BACKUP TO RETAIN PROGRAMMING DURING POWER OUTAGE. THERMOSTAT SHALL AUTOMATICALLY RESET TIME SCHEDULES FOR DAYLIGHT SAVINGS TIME. SUPPORT FOR MULTIPLE STAGE HEATING/COOLING (AS REQUIRED), ADJUSTABLE PARTIAL OR FULL KEYPAD LOCKOUT, 5-YEAR WARRANTY. 4. WHERE SPECIFICATIONS & PERFORMANCE ARE MET, ALTERNATE MANUFACTURERS (BY APPROVAL) ARE: CARRIER, AMERICAN STANDARD, LENNOX, MCQUAY. 5. DISCONNECT SWITCH SHALL NOT BE UNIT MOUNTED AND SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. DUCTLESS SPLIT SYSTEM SCHEDULE COOLING CAPACITY DATA EVAPORATOR ELECTRICAL DATA CONDENSER ELECTRICALMINIMUM DATA M TOTAL OUTSIDE UNIT AIR COOLED OUTDOOR UNIT N EVAPORATOR EXT. S.P. EVAPORATOR MANUFACTURER WEIGHT MINIMUM MANUFACTURER SEER WEIGHT SERVES POSITION AIRFLOW AIRFLOW ENTERING AIR MINIMUM MINIMUM MINIMUM RECOMMENDED CONDENSING UNIT AMBIENT fV MARK DROP IN. (LBS)AND MODEL NUMBER VOLTS PH BRANCH PROTECTION REFRIGERANT AND MODEL NUMBER RATING (LBS) CFM CFM TOTAL SENSIBLE HP VOLTS PH CIRCUIT OVERCURRENT MARK TEMP. 'F CIRCUIT RATING BASIS OF DESIGN) 0 ARI 'F DB 'F WB MBH MBH AMPACITY PROTECTION (BASIS OF DESIGN) AMPACITY AHU3-4 SEE PLANS WALL MOUNTED 810-920 --- --- 75' 62.5' 26.0 24.2 - 208 1 1 --- MITSUBISHI 50 CU3-4 105' 208 1 25 40 R410A MITSUBISHI SPLIT DUCTLESS MODEL PKA-A36KA4 MODEL PUY-A36NHA4 14.0 150 Q i $ r a NOTES: f- 1. CONDENSING UNIT SHALL BE PROVIDED WITH LOW-AMBIENT CONTROLS AS REQUIRED TO ALLOW OPERATION DOWN TO -10'F AMBIENT, HAIL GUARDS, AND 5-YEAR COMPRESSOR WARRANTY. THE CONTRACTOR SHALL DETERMINE EXACT LENGTHS OF REFRIGERANT LINES REQUIRED AND SUBMIT TO 0 V) MANUFACTURER FOR SIZING OF REFRIGERANT PIPE SIZING. PROVIDE ADDITIONAL COMPONENTS AS RECOMMENDED BY UNIT MANUFACTURER FOR PROPER OPERATION OF UNITS. THE CONTRACTOR SHALL INSTALL THE UNITS AND THE REFRIGERANT PIPING PER THE MANUFACTURER'S RECOMMEND INSTALLATION Q Q) 2 Wjj� JTIRP&RAMMABLE THERMOSTAT. 0 3. BASIS OF DESIGN IS MITSUBISHI. IF THE ABOVE PERFORMANCE SPECIFICATION IS MET, THEN ALTERNATE MANUFACTURERS (SUBMITTAL REQUIRED) ARE: DAIKIN, LG. �_ V 4. DISCONNECT SWITCH SHALL NOT BE UNIT MOUNTED AND SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. pC 5. PROVIDE CONDENSATE PUMP FOR EACH INDOOR UNIT EQUAL TO REFCO GOBI MODEL GOBI-115-UL. 3.2 GPH CAPACITY, 115-VOLT, COMPLETE WITH INTEGRAL CHECK VALVE, ELECTRONIC NOISE CONTROL, AQUA-SENSOR, BUILT-IN ALARM CIRCUIT, AND FILTER. MOUNT DIRECTLY BELOW DUCTLESS SPLIT SYSTEM UNIT. WIRE ALARM TO PROVIDE AUTOMATIC SHUT-DOWN OF DUCTLESS SPLIT SYSTEM UNIT. N/ m r) V / � Z t/1 V / LL.i cuN L Ce 0 uv J > OV Y-Epo .0 WE r � � � C o^orno I� ^ as > U � � � s Lr) ave- u, N V 2:_ (.0 O U d c M mechanical - electrical - plumbing -Y o L. inLoQ0.au. I3c SHEET: sso �aPei �,ai' Consulting Engineers 8217 Shoal Creek Blvd M4m I Suite 100 Austin, Texas 78757 512-407-9011 512-407-8287 (fax) I 0 N 7- PROFFs O �����I N E �2 AIR DISTRIBUTION DEVICE SCHEDULE FAN SCHEDULE 89617E 6 I�r - ORECrON NECK FACE TOTAL TOTAL FAN TYPE ELECTRICAL DATA OL p MARK SERVICE TYPE FINISH INCHES MANUFACTURER AND MODEL NUMBER MARK LOCATION SERVICE S.P. FRPM MANUFACTURER AND MODEL NUMBER "0 FMaER k INCHES CFM ARRANGEMENT SQUARE IN. WG HP WATTS VOLTS PH SONES NNEKgY ,_?1.08.2015 A SUPPLY SQUARE CEILING OFF-WHITE SEE PLANS 24"x24" TITUS MODEL OMNI EF-1 CEILING SEE PLANS 75 0.5 950 CEILING FAN --- 80 120 1 2 GREENHECK SP-1311110 EXPIRES 06/30/2015 B RETURN PERFORATED OFF-WHITE 22"x22" 24"x24" TITUS MODEL PAR, LAY-IN EF-2 CEILING SEE PLANS 150 0.5 1050 CEILING FAN --- 128 120 1 3.5 GREENHECK SP-B150 C SUPPLY VAV DIFFUSER OFF-WHITE SEE PLANS 24"x24" ACUTHERM MODEL TF-HC-R EF-3 CEILING SEE PLANS 100 1 0.5 950 CEILING FAN --- 80 120 1 2 GREENHECK SP-B110 D SUPPLY SQUARE CEILING OFF-WHITE SEE PLANS 12"X12" TITUS MODEL OMNI OAF-1 LEVEL 3 OUTSIDE AIR 635 1 0.5 --- INLINE FAN 1/4 --- 120 1 6.6 GREENHECK SQ-100-VG E SUPPLY ALUMINUM SPOT DIFFUSER ALUMINUM SEE PLANS N/A SEIHO MODEL PK 10 NOTES: 1. PROVIDE EF-1 THROUGH EF-3, WITH THE FOLLOWING: RETURN GRILLE, ISOLATION KIT, MOTOR W/ THERMAL OVERLOADS, DIRECT DRIVE, AND F RETURN HEAVY DUTY BAR RETURN REFER TO ARCH SEE PLANS NECK + 2" TITUS MODEL 63FL INTEGRAL SPRING LOADED BACKDRAFT DAMPER. H G SUPPLY LINEAR SLOT DIFFUSER OFF-WHITE SEE PLANS SEE PLANS TITUS MODEL ML-38 (2)-3/4" SLOTS WITH MPI-38 INSULATED PLENUM. 2. PROVIDE EF-1 AND EF-2 WITH AN ALUMINUM GRILLE. N 3. IF PERFORMANCE AND SPECIFICATIONS ARE MET ALTERNATE MANUFACTURER BY SUBMITTAL SHALL BE: COOK. z H SUPPLY SIDEWALL GRILLE REFER TO ARCH SEE PLANS NECK + 2" TITUS MODEL 272FS O 4- PROVIDE AF-1 WITH THE FOLLOWING: HANGING VIBRATION ISOLATION KIT, FILTER BOX W/ 2" ALUMINUM FILTERS, MOTOR W/ THERMAL OVERLOADS, w H I SUPPLY SIDEWALL GRILLE REFER TO ARCH 18"X12" NECK + 2" TITUS MODEL 30OFS AND INTEGRAL SPRING LOADED BACKDRAFT DAMPER. OAF-1 SHALL CONTROL BY CONSTANT STATIC PRESSURE. Ln V ZD Z ce 0 (- NOTES: Z 1• SUPPLY AIR DEVICES SHALL BE FOUR-WAY THROW UNLESS INDICATED OTHERWISE BY ARROWS ON PLANS. FOR 3-WAY, 2-WAY AND 1-WAY THROW PROVIDE OPTIONAL BLOW CLIPS MODEL "BP". ELECTRIC DUCT HEATER SCHEDULE Z � O 2. FLEXIBLE DUCT RUN-OUTS SHALL BE LIMITED TO 96-IN TOTAL LENGTH PER RUN-OUT. PROVIDE RIGID ROUND EXTERNALLY INSULATED DUCT FOR RUN-OUTS IN EXCESS OF 96-IN TOTAL LENGTH. SUPPORT o N LLJ FLEXIBLE DUCT WITH GALVANIZED STRAP HANGERS SPACED 3-FEET ON CENTER. ELECTRICAL DATA � Z V) MAX NO. OF ENTERING LEAVING U 0 5 ILLJ 3. DUCT RUN-OUTS TO AIR DEVICES SHALL BE EQUAL TO THE DIAMETER OF THE NECK SIZE INDICATED ABOVE, UNLESS ANOTHER SIZE IS NOTED ON PLANS. PROVIDE TRANSITION TO NECK SIZE DOWNSTREAM OF MARK SERVICE TYPE F.V. AIR AIR MANUFACTURER AND MODEL NUMBER w V TAP AND BRANCH DUCTWORK. FLEX DUCT SIZE SHALL BE EQUAL TO NECK SIZE, TYP. KW VOLTS PH FPM STAGES .F 'F 4. PROVIDE AIR DEVICES WITH FRAMES COMPATIBLE WITH CEILING TYPE. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE AND CONSTRUCTION DETAILS FOR PROPER CEILING MOUNTING FRAME. Ln 5. PROVIDE ALL TYPE "C" AIR DEVICES WITH 24V TRANSFORMER, WALL-MOUNTED TEMPERATURE ADJUST, AND PRESSURE RELIEF RINGS. EDH1-1 AHU1-1 SLIP-IN 15.0 480 3 --- 1 68 93.3 INDEECO QUA w o 0 ry r�3 HU -1 SLIP-IN 10.0 480 3 --- 1 68 96.2 INDEECO QUA ¢ 6. CONTRACTOR SHALL VERIFY AND COORDINATE ALL FINISHES WITH THE ARCHITECT. EDH3-1 Ao � N 7. CONTRACTOR SHALL COORDINATE EXACT LOCATION AND ELEVATION WITH THE ARCHITECT. EDH3-3 AHU3-3 SLIP-IN 3.5 480 3 --- 1 55 84.1 INDEECO QUA EDH1-3 AHU1-3 SLIP-IN 1 15.0 480 3 --- 1 55 78.7 INDEECO QUA o 0 LOWER SCHEDULE NOTES: - N 1• PROVIDE AIRFLOW SWITCH (SAIL TYPE), INSULATED CABINET, AND MAGNETIC CONTACTORS. TOTAL TOTAL TOTAL 2• ALTERNATE MANUFACTURERS (BY APPROVAL): MARKEL, REDD-I. DRAWN: JML MARK SERVICE LOCATION CFM S.P. AREA (FPM)FREE VELOCITY MANUFACTURER AND MODEL NUMBER IN. WG F2 CHECKED: Cg L-1 OUTSIDE AIR INTAKE SEE PLANS <200 <0.05" 0.35 <500 GREENHECK EDJ-401 - (18"W X12"H) JOB NO: 1314 L-2 EXHAUST AIR SEE PLANS <300 <0.05" 0.43 <750 GREENHECK EDJ-401 - (12"W X12-H) MATRIX OF RESPONSIBILITY L-3 OUTSIDE AIR MAKEUP SEE PLANS --- --- 11.95 <500 GREENHECK ECD-401 - (60"W X60-H) Ifly L-4 OUTSIDE AIR INTAKE SEE PLANS 400 <0.05" 0.74 <500 GREENHECK EDJ-401 - (18"W X18-H) EQUIPMENT LOW VOLTAGE WIRING Final L-5 OUTSIDE AIR INTAKE SEE PLANS <200 <0.05" 0.35 <500 GREENHECK EDJ-401 - (12"W X18-H) Furnished Installed Start Furnished Installed Tonnectiot MEP SYSTEM DESCRIPTION BY BY Up BY BY By By REMARKS NOTES: 1. PROVIDE BIRDSCREEN CONSTRUCTED OF 304 STAINLESS STEEL, FLANGED BORDER FOR MOUNTING, AND COORDINATE COLOR WITH ARCHITECT AND CHILLERS Trane MC Trane Trane Trane Trane SUBMIT FINISH COLOR SAMPLES TO ARCHITECT/ENGINEER PRIOR TO ORDERING LOUVERS. Receive,offload, inspect and store Trane IMC I Report Freight damage immediately 2. LOUVER L-33 SHALL BE A COMBINATION LOUVER/DAMPER. INSTALL 120V ACTUATOR WITH CONTROL RELAY TO ACCEPT INPUT FROM OWNER Neoprene Isolation Pads Trane MC Jensen / Fey WINDTUNNEL PLC CONTROL SYSTEM. First year parts warranty Trane Trane Trane First year labor warrant Architecture and Planning Y Y Trane Trane Trane 7730 LEARY WAY NE Containment for Low Voltage Wiring EC Trane REDMOND, WA 98052 TEL:42 5.216.0318 FAX:425.216.0329 ELECTRIC SPECIALTY HEATER SCHEDULE SPLIT SYSTEMS(Std&Heat Pumps) Trane MC MC MC MC MC Also includes Ductless Split Systems Receive,offload,inspect and store MC ELECTRICAL DATA LENGTH HEATER MOTOR Filters(One Set) Trane MC Refrigerant Piping MC MC MC MARK LOCATION TYPE IN WATTS POWER MANUFACTURER AND MODEL NUMBER VOLTS PH FEET (KW) WATTS Refrigerant Specialties MC MC MC I EKH1-1 THRU 1-2 RECEPTION 102 KICKSPACE HEATER 120 1 - 1500 --- MARKEL TSH2OJ Evaporator Defrost Control Trane MC MC MC MC MC Vibration Isolation Trane MC ECH-1 & ECH-2 STAIRS VERTICAL CABINET 277 1 - (6) 58 TRANE FFB-040 Condensate Pumps MC MC MC IMC MC MC I Drain Pan Float Switches MC MC MC MC MC MC R NOTES: Smoke Detectors/Firestats EC EC EC EC EC EC Fire Alarm Provider to wire for unit shutdown LL 1- PROVIDE RECESSED FLOOR HEATERS WITH (1) WALL MOUNTED LOW VOLTAGE Thermostats Trane MC MC MC MC MC HEATING THERMOSTAT. PROVIDE BUILT-IN LOW VOLTAGE RELAY C/W TRANSFORMER. Disconnects EC EC EC COORDINATE ELECTRICAL CONNECTION WITH ELECTRICAL CONTRACTOR. Outside Air Dampers/Actuators MC MC MC MC MC MC 2. RECESSED FLOOR HEATERS SHALL BE PROVIDED WITH STAINLESS STEEL FINISH. Electric Duct Heaters MC MC MC MC MC MC 3. PROVIDE KICKSPACE HEATERS WITH INTEGRAL THERMOSTAT KIT. First year parts warranty Trane First year labor warranty MC MC MC MC MC Interconnecting Wiring MC MC MC MC MC MC M Containment for interconnecting wiring MC MC MC MC MC N Field installed split system components Trane MC MC MC MC MC Items listed on Trane's scope letter as FLD ELECTRIC UNIT HEATER SCHEDULE a, Mitsubishi to provide the VFD's for the wind Variable Frequency Drives Trane EC Trane Trane Trane Trane tunnel fans 0 FAN DATA ELECTRICAL DATA MARK LOCATION TYPE MANUFACTURER AND MODEL NUMBER Interlock wiring if Disconnect is Dowstream of VFD EC EC Trane EC EC EC Used to disable VFD if Disconnect is off CFM DRIVE TYPE KW HP VOLTS PH TRAINING Chillers Trane 1715 EUH-1 MECH. MEZZANINE SUSPENDED 2800 DIRECT 50.0 --- 480 3 MARKEL SERIES 5100 Split Systems MC Includes thermostat training if required EUH-3 FIRE RISER SUSPENDED 400 DIRECT 3.3 --- 277 1 MARKEL SERIES 5100 Controls Trane NOTES: f-c� 0 V) v, O1. UNIT HEATERS SHALL BE HEAVY DUTY, SUSPENDED, HORIZONTALLY MOUNTED, ELECTRIC UNIT HEATERS. PROVIDE EACH UNIT WITH A MARKEL HVAC AUTOMATION SYSTEM Trane Trane Trane Trane Trane Trane � - MODEL T5100 BUILT-IN THERMOSTAT, AND MOUNTING BRACKET. PLC Interface Panel iFly iFly iFly iFly iFly iFly C) 2. EUH-1 T'STAT SHALL BE SET TO 60-F (ADJUSTABLE). Chiller/Pump Sequencing Panel Trane Trane Trane Trane Trane Trane �_ V Engineered Drawings/Submittal Trane Controls Commissioning Trane Ln First year Parts and labor warranty for Trane z r a INTAKE AIR HOOD SCHEDULE controls Trane r� W 0 Low Voltage Wiring associated with Trane LJJ `" Automation system Trane Trane Trane Trane Trane Trane Excludes split system, PLC,and interlocks V J > (� MAX Provide pull strings L' TOTAL TOTAL TOTAL Conduit EC EC p gs in all conduit runs O V --0 O o �V ID MARK LOCATION SERVICE CFM S P TMgRRE�p T MANUFACTURER AND MODEL NUMBER 120/1 Power EC EC Power terminations by EC " L^ C trr� c) IN. WG FTZLn > p ^ v _ rt IH-1 ROOF OUTSIDE AIR 635 0.05 1.45 GREENHECK GRSI-16 V Ln HVAC TEST AND BALANCE MC MC (.0 0 3 v O V ' Y C mechanical - electrical - plumbing _k 0 3 � Trane= National Account Vender contracted to ifly for HVAC and Controls NOTES: EC= GC's Electrical Contractor -- 1. REFER TO DETAIL FOR INSTALLATION INFORMATION. GC= General ContractorI Pei SHEET: 2. PROVIDE IH-1 WITH ALUMINUM BIRDSCREEN, ALUMINUM HOUSING, 30" HIGH FACTORY ROOF CURB (INSULATED WITH 2" MC= Mechanical ContractorINSULATION), 120V MOTORIZED DAMPER, 1" THICK HOOD INSULATION, ALUMINUM MESH INSECT SCREEN IN FRAME. HVAC NATIONAL ACCOUNT AGREEMENT 4 ssocia TRANE is the approved National Account Vendor for HVAC equipment and accessories Consulting Engineers Trane Contact: Micah Lightfoot Under this agreement the following items have been purchased from Trane: -Chillers National Account Executive 8217 Shoal Creek Blvd M402 Split Systems Cell Number:972-919-2376 Suite 144 -HVAC Automatic Temperature Control System E-mail:mlightfoot@trane.com Austin, Texas 78757512-407_9011 512-407-8287 (fax)