Loading...
Plans (9) L 2 0 I ) , -�, Uu' ,-,, CEILING LEGEND: WHICH WICH 2015 LIGHTING FIXTURE SCHEDULE � W A W w O RECESSED LIGHT SYMBOL FIXTURE WATTS LAMP VOLTAGE LOCATION NOTES: ` ����/ ��_U � o A MANUFACTURER: LITON 16W JINTEGRALLED 120 DINING AREA -- .�/ �t-t -5 ui B DESCRIPTION: 6" LED RECESSED W/BLACK RING -' � N O RECESSED LIGHT WITH GLASS LENS -� � o � N MODEL: LH71CA-LLF-GU24/LRELD602CB-L10 A B MANUFACTURER: LITON 16W INTEGRAL LED 120 DINING AREA y 3" �'� ' t �I S TRACK HEAD DESCRIPTION: 6" LED RECESSED W/WHITE RING 0) O MODEL: LH71CA-LLF-GU24/LRELD602C-L10 LO C) 0 2 TRACK C NOT USED -- -- -- -- -- i 2X4 LAY-IN FLUORESCENT LIGHT FIXTURE D MANUFACTURER: JUNG 9W TCP 120 DINING AREA -- � ctiq DESCRIPTION: MINI UNIVERSAL TRACK HEAD-BLACK LED8P20D30KNFLB F MODEL: R541 BL E MANUFACTURER: JUNO N/A N/A 120 DININGAREA -- ('lr1 LA FEB 17 2X2 LAY-IN FLUORESCENT LIGHT FIXTURE DESCRIPTION: MINI UNIVERSAL TRACK&LIVE FEED END-BLACK Z�I6 MODEL: R2BL/R4BL/R38BL H F 96W GE DESCR PT ON:2X4 RECESSED TROFFER 3-LAMP 3) F28T8/XL/SPX35/ECO 120/277 KITCHEN BALLAST FIY "FIELD I�� �I� Div, EXIT LIGHT ILLUMINATED W/ BATTERY BACK-UP, 6 MODEL:2GR8-332A-UNV-EB81-U INSTALL o EXIT INCH HIGH LETTERS H MANUFACTURER: ORACLE 64W GE 120/277 SERVICE "EM"EMERGENCY DESCRIPTION: 2X2 RECESSED TROFFER 2-LAMP (2) F28T8/XL/SPX35/ECO AREA BALLAST"FIELD EMERGENCY LIGHT MODEL: 2RG8-2U6T8A-UNV-EB81-U INSTALL" X MANUFACTURER: MAXILUME 2W INTEGRAL LED 120/277 EXIT(S) -- s DESCRIPTION: EXIT SIGN-WHITE BODY W/RED LETTERS r" NOTE: MODEL:VEX-U-BP-WB-WH ` �` LIGHTING TRIM TO MATCH CEILING COLOR. Y MANUFACTURER: MAXILUME 10W (2) INTEGRAL T5 WEDGE 120/277 AS SHOWN -- (BLACK CEILING = BLACK TRIM) DESCRIPTION: EMERGENCY BUG-EYE-WHITE ON RCP 7 (WHITE CEILING = WHITE TRIM) MODEL: LED-90 Z MANUFACTURER: MAXILUME 10W (2)INTEGRAL MR16 120/277 AS SHOWN -- LO DESCRIPTION: EMERGENCY RECESSED-WHITE ON RCPE E IT MODEL: ELM-621 2X4 OR 2X2 SUSPENDED CEILING NOTES: '• a,. o 1. LUMINAIRES &LAMPS FURNISHED BY VILLA LIGHTING SUPPLY: ' 4 N B.. a• •�n B.•.a•fir DAN ZIPF .. NOTES: 2929 CHOUTEAU AVENUE O O •^_0 ST. LOUIS, MO 63103 7 ., ,. ... o W 1. ALL CEILING DEVICES INCLUDING LIGHTING & HVAC IS NEW, P: 314.633.0422, EMAIL: dan.zipf@villalighting.com I' UNLESS NOTED OTHERWISE. 2. ALL FIXTURE TYPES MAY NOT BE USED. F F ;:,.; .<`. : '. p 3. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR FIXTURE MOUNTING HEIGHTS. 13 a.'! 13 2. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR 4. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORAGE, INSTALLATION,AND WIRING OF LIGHT FIXTURES. co ADDITIONAL INFORMATION. +8-6" , 5. THE ELECTRICAL CONTRACTOR SHALL REPORT ANY DAMAGED LIGHT FIXTURES OR MISSING PARTS TO VILLA LIGHTING WITHIN 48 HOURS AFF OF RECEIPT OF LIGHT FIXTURE PACKAGE. 10 �•�'• WHICH WICH NOM. 2' SIGNAGE (INTERIOR) GC TO INSTALL ALL OWNER PROVIDED SIGNS 6 PROJECT#: 570 CROSS TEEHANGER . LAY—IN- WIRE G1 PAY HERE SIGN "J"-BOX GC TO INSTALL ON SERVICE SIDE OF SOFFIT O G2 PICK UP HERE SIGN "J"-BOX GC TO INSTALL ON SERVICE SIDE OF SOFFITg' a A ° 1. G3 WWDYW SIGN OUTLET @ 9-7"AFF. GC TO ABOVE MENU BOARDS AS INDICATED ON Q F " +8-6" 1 ELEVATIONS Ile AFF..° +9-0" 7' BAR MAIN BEAM AFF G4 OPEN SIGN OUTLET @ CEILING ABOVE FRONT ENTRY DOOR GC TO INSTALL ABOVE FRONT DOOR +10-o" 2-0 _ 13 ••• AFF WASH 4.. PRELUDE/ G5 MEDALLION SIGN OUTLET @ CEILING AT STOREFRONT GC TO INSTALL IN STOREFRONT `: y..• `-�.. ,�.'A:..••.• 6 INTERLUDE MAIN NOM. 4' DROP CEILING DOWN TO 9-0" A.F.F. BEAM CROSS TEE G6 "SANDWICHFACTION -- GC TO INSTALL PER EQUIPMENT PLAN, AT REAR 6 TEGULAR EDGE GUARANTEED"SIGN SERVICE WALL �— AT CORRIDOR TO RESTROOMS LAY-M PANELS GENERAL NOTES FOR STANDARD CEILING SYSTEMS: SQUARE EDGE m_ A 1 • INSTALL PER ARMSTRONG INSTALLATION SPECS. LAY-IN-PANELS O O O -1 7 LU LU • FIELD VERIFY ALL CONDITIONS AND DIMENSIONS. STUD GAUGE SCHEDULE 16 9 GYP BOARD SOFFIT-BOTTOM AT 8-0" F 6.0 F F AFF, PAINTED P-2 cn A SUSPENDED GRID DETAIL � �" A. TABLE BELOW IS BASED ON UNIVERSAL INDUSTRIES, UNIMAST O (USG)CORPORATION S LIMITING HEIGHT TABLE FOR EMBRACED1 3 2E W O STUDS SPACED 16"AND 24"O.C. (SYSTEM FOLDER SA-923-1990 G6 a INDICATES AREA OF GYP BD CLG 5/8 EDITION). REQUIREMENT FOR 5 PSF LATERAL PRESSURE AND 6.0 4 ♦ \ Q cl) Q a TYPE WR GYP BD ON 20 GA MTL STUDS @ 1/240 ALLOWABLE DEFLECTION FOR FLEXIBLE FINISHES,WITH 1 v 24" OC AT (SEE PLAN) LAYER OF GYP. BD. PER SIDE OF STUD. O O O O2 2 A A U H H H H I 1 daX .B. SCHEDULED HEIGHTS MAY BE INCREASED BY 50%WHERE THE GYP BOARD SOFFIT ABOVE 11 CD d STUDS ARE DIAGONALLY BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE ABOVE @ 4-0"O.C. SERVICE COUNTER - BOTTOM AT 6 14 AFF WA H 8-0" AFF PAINTED P-1 C. CAUTION!WHEN USING STUDS MANUFACTURED BY A COMPANY SOFFIT TO REFLECT SAME INDICATES AREA OF WASHABLE CEILING OTHER THEN USG.VERIFY MANUFACTURERS STUD STRENGTH FOOTPRINT OF COUNTER BELOW HO HO HO 3 AND LIMITING HEIGHT.ADJUST GAUGE AND MAXIMUM HEIGHT TILES - SEE PLAN FOR HEIGHT AFF RECOMMENDED BY MANUFACTURERS CURRENT PRINTED G1 �T 6 0 13 B SPECIFICATION. S20 S2o C'2 A STUD WIDTH STUD TYPE STUD GAUGE STUD SPACING MAX. HEIGHT °. INDICATES AREA OF 2X2 (2X4) LAY-IN 1-5/8" 158ST25 25 16" 9-6" CEILING TILES - SEE PLAN FOR HEIGHT 158ST25 25 24" 7-3" 4'4" 6'-0" 6'-0" 9 1 AFF 2-1/2" 212ST25 25 16" 12-6" S20 S20 212ST25 25 24" 10-9" 4 212ST22 22 16" 13-0" _E E 9 AFF WASH 212ST22 22 24" 11-6" 212ST20 20 16" 14-0" 4 4 4 GYP BOARD SOFFIT ABOVE SODA 212ST20 20 24" 12-3" A A A A A A COUNTER - BOTTOM AT 8-0" AFF KEYED NOTES: TA PAINTED P-1 O 3-5/8" 358ST25 25 16" 16-0" 358ST25 25 24" 13-6" 358ST22 22 16" 17-3" 1 1 1 1 1 1 1 SOFFIT TO REFLECT SAME 1. RECESSED LIGHT (LIGHT"A") 358ST22 22 24" 15-0" NOTE: FOOTPRINT OF COUNTER BELOW 0 2. FLUORESCENT 2 X 2 LIGHT FIXTURE (LIGHT "H") 358ST2o 20 16" 18-3" SEE MECHANICAL FOR EXACT LOCATION OF 4 3. NOT USED 358ST20 20 24" 16-0" DIFFUSERS W 4. 2 TRACK (LIGHT"E") WITH TRACK HEAD (LIGHT "D") 6" 600sT25 25 16" 20-0" 5. FLUORESCENT 2 X 4 LIGHT FIXTURE (LIGHT"F") 600ST25 25 24" 15-0" NOTE: A A A A A A A CEILING MOUNTED "OPEN" SIGN 6. EMERGENCY LIGHT (LIGHT"Y") SEE ELECTRICAL SHEETS FOR LIGHTING 7. EXIT LIGHT (LIGHT "X") SPECIFICATIONS AND EMERGENCY LIGHT PACK SUSPENDED ABOVE DOOR - SEE 8. NO CEILING ABOVE WALK-IN COOLER/FREEZER LOCATIONS. 1 1 1 1 1 1 1 ELEVATIONS 9. GYP BOARD SOFFIT- SEE PLANS FOR AFF HEIGHT G4 10. 2 X 4 WASHABLE LAY-IN CEILING AND GRID NOTE: G3 4 k 11. 2 X 2 WASHABLE LAY-IN CEILING AND GRID ALL GRILLES/DIFFUSERS TO MATCH CEILING ,,, C12 +12-0" AFF 7 12. 2 X 2 LAY-IN CEILING AND GRID 13. RECESSED LIGHT (LIGHT"B") TILES - SEE MECHANICAL SHEETS FOR EXACT 14. EXHAUST HOOD LOCATIONS A A A A A A A EXTERIOR SIGN UNDER SEPARATE PERMIT -13NOTE: Q- PROVIDED BY SIGN COMPANY & INSTALLED BY 1 1 1 1 1 1 G SIGN COMPANY GC TO VERIFY MAX CEILING HEIGHT IN FIELD - CONTACT NOTE: 4 PROJECT MANAGER IF LESS SIGN MANUFACTURER TO SUBMIT TO LANDLORD DETAILED CUT SHEETS FOR MAIN STOREFRONT SIGN. LANDLORD 2-6" A A A A A A A THAN 12 MUST APPROVE ALL SIGNS IN WRITING PRIOR TO FABRICATION. CIT Y QF'T'jGD O� _._ r REVIEWED FOR CODE COMpY. lm 1 1 1 1 1 1 61 El Approveds THIS DRAWING AND ITS CONTENTS ARE THE COPYRIGHTED PROPERTY OF FM GROUP INC. USE THEREOF IS LIMITED TO THE SPECIFIC NOTE: 7 OTCS PROJECT AND SITE SET FORTH ABOVE,AND ALL LIGHTS IN THE PREPARATION AREA, STORAGE AREA, Permit# ( ( - 2 MAY NOT BE OTHERWISE USED OR REPRODUCED,IN WHOLE OR IN PART,WITHOUT DISHWASH AREA, WALK-IN REFRIGERATOR, AND FREEZER An _ Address: -7 76C;'-9 � - THE WRITTEN PERMISSION OF FM GROUP INC, MUST HAVE SHATTERPROOF COVERS. s THE ARCHITECT.THIS DRAWING IS TO BE SUItC : /7` RETURNED UPON REQUEST By: �t G—> Dates 2 CEILING MOUNTED "OPEN" SIGN G4 G5 CEILING MOUNTED MEDALLION SUSPENDED ABOVE DOOR - SEE SIGN SUSPENDED IN WINDOW- N ELEVATIONS SEE ELEVATIONS NORTH OFFICE COPY (--) REFLECTED CEILING PLAN c� C� SCALE: 1/4" = 1 -0" o T_ Y Q � � U