Plans (9) I� l I i i i i FLOW TEST DATA HYDRAULIC AREA Static Pressure 60 psi Density .05 gpm/sgft Flow 1230 gpm Area 2 heads Residual Pressure 48 psi Required Flow 26.4 gpm Test Date 15 Dec 2014 Required Pressure BOR 25.4 psi Hose Flow Included 0 gpm RE ' EP JAN 6 2016 CIT V OFTIGARD BUILDING DIVISION, I l I OTILE O 2-1 Li SHOWER 3 co, WALK—IN 4-4 5-2 '2 3-4 6-0 g' CLG. 4-0 0 URN. MASTER SUITE 0 GARAGE 18/0x13 0 0 20/8 x 19/2 O N 00 �' W. X rn O rL cfl D. Y 3-0 V z :OE z 9�L�F 9C m\ LINEN a- �F F1 of 9' CLG. GREAT ROOM U, PORCH FOYER 18/4x15/8 z CONCRETE _ o -"J t2 o,o COVERED U - - - - - - - -° - - - - - - - - - - DECK "-SOL-PJM 10/0x18/0 6x� POST W 2x WRAP D s h I CITY OF'TIGARD 5 K . h2 0 Z O EW REVIEW FOR CODE OC3MI'LIANC9 7-0 1-2 7-6 ,-4 5-10 3-8 4-2 12-4 I ApP�� 9' CLG. 9' CLG. DEN BR . 3 BR . 2 I 9' CLG. I °T � DINING 12/6x10/8 12/6x10/8 ,}, I Pcrinit#: [�~ 15/0x10/0 ( � ® ` I Suite#3 Sys Dates REF. DW PANTRY - - - -_ _ _ _ _ _ - OFFICE COPY El MAIN FLOOR PLAN 1905 SQ. FT. O FT 2 FT 4 FT 6 FT 8 FT 10 FT 12 FT NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-1 All piping and fittings to be CPUC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 1 MM R-OM PLAN All hangers to be CPVC Standoff type and located per NFPA 13D requirements. O Concealed Pendant, 4.9 K—factor, 160', Quick Response, Qty. 15 , Max. sprinkler spacing to be 16'x 16'w/8'-0"off walls. ° ' PERMIT NO. All CPVC i in to be 1"w/Riser to be 1"black steel I Ing. WYATT 15230 SW HARVEY'S VIEW AVE. p p g p p ° ti CONTRACT No. C15-755 Meets design requirements of NFPA 13D 2013 edition. - v All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). _ �8 FIRE PROTECTION, INC. TIGARD, OREGON 97224 APPROVAL Riser to be connected to domestic water prior to hot water heater. M.COLLEY Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information oni 9095 S.W. Burnham DRAWN BY 1 plumber) y. Tigard, OR 97223 SCALE 1/4"= 1'-0" (503) 684-2928 DATE 4 JAN 2016 STONEBRIDGE HOMES, 4230 GALEWOOD ST,#100, LAKE OSWEGO, OR 97035 REVISED PLOTTED FP 1 of 3 RECEIVED JAN 6 2016 C111 Of HGARD BUILDING DIVISION 5'-8" HIGH WALL J Q 8' CEILING J M I = I ® 2-6 - 2 = 14-6 8' CLG. BONUS 37/0x12/0 DECK 10/0x10/0 UPPER FLOOR PLAN 480 SQ. FT. 0 FT 2 FT 4 FT 6 FT 8 FT 10 FT 12 FT NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-2 All piping and fittings to be CPUC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 1 All hangers to be CPVC Standoff type and located per NFPA 13D requirements. O Concealed Pendant, 4.9 K—factor, 160', Quick Response, Qty. 4 UPPER FLOOR PLAN Max. VC pips spacing to be is x 16'w/ " black off walls. f W")rAT T PERMIT NO. All CPVC piping to be 1"w/Riser to be 1" black steel piping. '' CONTRACT NO. C15-755 Meets design requirements of NFPA 13D 2013 edition. x 15230 SW HARVEY'S VIEW AVE. All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). FIRE P R 0 T E C TION� INC. TIGARD OREGON 97224 APPROVAL Riser to be connected to domestic water prior to hot water heater. ' DRAWN BY M.COLLEY Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 90955 S.W. Burnham 1/4" plumber) Tigard, OR 97223 SCALE {503) 684-2928 DATE 4 JAN 2016 STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 IREMED PLOTTED FP 2 of 3 nECEIVEP JAN 6 2016 CITY OF"TIGARD BUILDING DIVISION TO SYSTEM n3 ` --1"CPVC PRESSURE GUAGE n2 POTTER VSR-S WATERFLOW 1"DCVAAMES ALARM SWITCH SERIES 2000B n1 1"EDDY-THREAD SCHED.30 TO METER AND SUPPLY MAN. TRUSSES ® 24" O.C. W/ R-49 BLOWN—IN INSULATION & R-21 BLOWN—IN INSULATION @ T.O.W. 2x4 STUDS @ 16" O.C. O P . BONUS FLOOR I 1/2" CHIPBOARD OVER 1-118" T&G ENG. PLYWOOD ON 11 7/8' L.P.I. 20 JOISTS @ 24" O.C. B — RISER DETAIL I 1 3/4"x11 7/8" LVL 1 3/4"x11 7/8" LVL I RIM JOIST ' I 12"OF BATT OR PORCH FOYER HALL GREAT ROOM BLOWN-IN INSULATION BRANCHLINE W/PIPE STRAP MEDIUM WEIGHT PLASTIC GRADED BACK BARRIER OVER LINE PIPING TO MAIN I 1/2" CHIPBOARD OVER 1-118" T&G ENG. PLYWOOD ON 11 7/8' L.P.I. 20 JOISTS ® 24" O.C. ; 1"x DROP (SEE PLAN) CONC. SLAB AR-38 INS. R-38 INS. 2X RAMING CRAWL SPACE o GYP. BOARD o! QQ fr CROSS SECTION B � � W Q zQ A — CROSS SECTION C — TYPICAL INSULATION COVER 0 FT 2 FT 4 FT 6 FT 8 FT 10 FT 12 FT NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-3 All piping and fittings to be CPVC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 1 All hangers to be CPVC Standoff type and located per NFPA 13D requirements. s CROSS SECTION AND DETAILS Max. sprinkler spacing to be 16'x 16'w/8'-0"off walls. PERMIT NO. Wl)rATT All CPVC piping to be 1"w/Riser to be 1" black steel piping. 1 =� 15230 SW HARVEY'S VIEW AVE. CONTRACT NO. C15-755 lI Meets design requirements of NFPA 13D 2013 edition. r All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). APPROVAL PROTECTION INC. ' TIGARD OREGON 97224 Riser to be connected to domestic water prior to hot water heater. =` DRAWN BY M.COLLEY Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 9095 S.W. Burnham plumber) Tigard, OR 97223 SCALE _ - (503) 684-2928 DATE 4 JAN 2016 STONEBRIDGE HOMES, 4230 GALEWOOD ST,#100, LAKE OSWEGO, OR 97035 REVISED PLOTTED FP 3 of 3