Loading...
Plans (10) PS2015 00200 FLOW TEST DATA HYDRAULIC DEMAND Static Pressure 60 psi Density .05 gpm/sgft Flow 1230 gpm Area 2 heads Residual Pressure 48 psi Required Flow 28.6 gpm Test Dote 15 Dec 2014 Required Pressure BOR 33.3 psi Hose Flow Included 0 gpm RECEIVED DEC 16 2015 CITY OF TIGARD BUILDING DIVISION I i i O COVERED i 9' CLNG. 12/0x8/0 WALK—IN 5-2f ( U I I\�{ I� I 8' CLNG. 4 9' CLNG. M. C TL GREAT R M . 10/0x15/4 ns n5 N r-s• 17/0x1 4/6 2-6• 4-11 1-2 n6 17/0x15/4 1-110 1-2 7-4 5-4 2-8 6-6 0n75-6 n4 n5 r-ozz' 77ED co I 6.-0• � i i - 8' CLNG. ® i o-o Q BIR /I . 5 11 /0x12/8 - - ---- 0 2_D• o o Go ( o �-� L LINEN g -_ 7-2 8' CLNG. - - - 1- BDPN 11 /0x13/6 GARAGE PANTR Ln s-4• 20/2x22/8 8 CLNG. 3'-10• 8'-D' H01\IUS LOr 1 n9 n1 $' LI T 14 2x12/0 O n 1 i 4-0 -2r: 5-s7/6x9/'8' 2-0 10 3-2 0 12- 4-0 n 9 14 � 1 6'-0• � M .i Li — CITY OF TIGARD 6-D• I h 1 I ! REVIEWED FOR CODE COMPLIANCI OI - Approved: OTC; ` I OTC: n1 n 1 1��= � Permitt#: CJ.1 j —_, I Address: - �- f N Suite ' 1 $3,; Date. 5-9 � `Z I h2 L ( � l 3 � COVERED j I 9' CLNG. I OFFICE COP PORCH 12/0x10/2 I I `HYDRAULIC REMOTE AREA: DE _ J MAIN FLOOR PLAN UPPER FLOOR PLAN 1145 SQ. FT. 1420 SQ. FT. NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-1 All piping and fittings to be CPVC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 13 MAIN+U FLOOR PLAN All hangers to be CPVC Standoff type and located per NFPA 13D requirements. O Concealed Pendant, 4.9 K-factor, 160', Quick Response, Qty. 21 Max.sprinkler spacing to be 16'x 16'w/8'-0"off walls. PERMIT NO. All CPVC piping to be 1"w/Riser to be 1"black steel piping. WYATT 15020 SW HARVEY'S VIEW AVE CONTRACT NO. C15-733 Meets design requirements of NFPA 13D 2013 edition. " t =; All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). FIRE PROTECTION, INC. TIGARD OREGON 97223 APPROVAL Riser to be connected to domestic water prior to hot water heater. DRAWN BY M.COLLEY Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 9095 S.W. Burnham plumber) Tigard, OR 97223 SCALE 1/4"= 1'-0" DATE 18 NOV 2015 (503) 684-2928 STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 REVISED PLOTTED FP 1 of 2 TO SYSTEM n3 1"CPVC PRESSUREGUAGE n2 POTTER VSR-S WATERFLOW 1"DCVA AMES ALARM SWITCH SERIES 2000B n1 1"CPVC TO METER AND SUPPLY 0 �I I FLOOR - B - RISER DETAIL UTILITY i BONUS LOFT BDRM . 2 12"OF BATT OR BLOWN-IN INSULATION �.. 6d BRANCHLINE MEDIUM WEIGHT PLASTIC W/PIPE STRAP GRADED BACK BARRIER OVER LINE PIPING - _ TO MAIN I 1"x DROP (SEE PLAN) { 2X RAMING HALL BATH PANTRY GARAGE �YP. BOARD 0 QFd � = d � 0 0 (j) � w wQ z � CROSS SECTION C - TYPICAL INSULATION COVER NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-2 All piping and fittings to be CPVC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 13 s All hangers to be CPUC Standoff type and located per NFPA 13D requirements. Max. sprinkler spacing to be 16'x 16'w/8'-0"off walls. PERMIT NO. All CPVC piping to be 1"w/Riser to be 1"black steel piping. WYAT I 15212 SW HARVEY'S VIEW AVENUE CONTRACT NO. C15-733 Meets design requirements of NFPA 13D 2013 edition. All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). ('IRE PROTECTION INC. TIGARD OREGON 97223 APPROVAL Riser to be connected to domestic water prior to hot water heater. ' DRAWN BY M.COLLEY Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 9095 S.W. BurnhamSCALE 1/4"= 1'-0" plumber) Tigard, OR 97223 DATE 18 NOV 2015 (503) 684-2928 REVISED STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 PLOTTED FP 2 of 2