Plans (15) FPS2015 - 00170 FLOW TEST DATA HYDRAULIC AREA 1 Static Pressure 60 psi Density .05 gpm/sgft now 1230 gpm Area 2 heads Residual Pressure 48 psi Required Flow 26.3 gpm Test Date 15 Dec 2014 Required Pressure BOR 30.8 psi I ra I Hose Flow Induded 0 gpm � HYDRAULIC AREA 2 Density .05 gpm/sgft OCT 2 1 20 15 Area 2 heads �CITY OFTIGARoy Required Flow 325 gpm �• i�,`it�yloJ Required Pressure BOR 39.0 psi BUILDING p tl} 1 Hose Flow Induded 0 gpm A A I I I I I 1 t. ..... IDN I I r j COVERED DECK 9' CLG. 18/0 X 10/0 1 - NOOK , 13/0 HYDRAULIC AREA 2 f 0.05 GPM OVER 2 HEADS - --- --- 324 SQFT/HEAD DW RFs, <S�>o7 110j 8' CLG. WALK-INco I j 4'-11` 12/6 X 9/10 2'-6' KITCHEN m 4'- ' z ! 1. 1 n� 6-10 � I 17 + n �DMASTER 8�7 LG.O Z W Oo¢'- m I o — N I 17/10X14/6 j 9' CLG. =P 3 10• I I N GREAT RM . ' ' � bao m t n5 I 20/0 X 16/0 n6 DN wm , LLJ PANTRY I U BENCH'ltw I ' 4'2 F RAULIC AREA 1 b 3 J M® I 0.05 GPM OVER 2 HEADS M 256 SQFT/HEAD -� I r UTILITY / J I 8' CLG. ((DID BR . 4 I M s'-o• I 9' CLG. 12/6 x 11/0 , 2-0 I DINING 4!-V N 13/10 X 11/2 gam• o l _.. 4-5 1 I to C -0 2-° UP � UP SHOWER 10 m :� 1 ;; M LINEN 4 Y o- r I FLUE ro ar' n1 I ,o h3 I 8' CLG. RAIL 7-8 n �' -� BONUS - 141 19/0 X 12/6 I 1 n11 4-tt• U0-6 3-8 3-9 2-0 8-8 4- 6-2 6-9 0- OPEN I TO ABOVE % 1 8 CLG. g Y E R 6-°� 0�EN TO BR . 2 �� J 'FLOW GARAGE 9' CLG. 12/0 X 11/2 c OF TIGAM 21/0 x 21/10 I j V 'o FOR COU$corn DEN /BR . 5 12/0 x 10/0 I _ A."ro"& ❑ co -- --- � -- --- ; i Adams suite#S I Br Date: I I OFFICE COPY j PORCH CONCRETE A A MAIN FLOOR PLAN UPPER FLOOR PLAN 1490 SQ. FT. 1 ,520 SQ. FT. OFT 2 FT 4 FT 6 FT 8 FT 10 FT 12 FT OFT 2 FT 4 FT 6 FT SFT 10 FT 12 FT NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-1 All piping and fittings to be CPUC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 21 All hangers to be CPVC Standoff type and located per NFPA 13D requirements. O Concealed Pendant, 4.9 K-factor, 160', Quick Response, Qty. 23 MAIN♦UPPER FLOOR PLAN Max.sprinkler spacing to be 16'x 16'w/8'-0"Off walls. PERMIT NO. All CPVC piping to be 1"w/Riser to be 1"black steel piping. Meets design requirements of NFPA 13D 2013 edition. W YAT T 12080 SW Autumn View St CONTRACT NO. C15-685 All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). FIRE PROTECTION, INC. TIGARD OREGON 97223 APPROVAL s Riser to be connected to domestic water prior to hot water heater. Double check to be provided b p y p ( g h 9095 S.W. Burnham DRAWN BY A NISHIHARA p y Wyatt Fire but installed, permitted and tested b lumber contact Stonebridge Homes for information on '�; plumber) Tigard, OR 97223 SCALE 1/4"= 1'-0" (503) 684-2928 DATE 21 OCT 2015 STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 REVISED PLOTTED FP 1 of 2 REC' jv S ar OCT 2 7 2015 cfy'Ll vrx1 Q9 VrSrQN TO SYSTEM n3 ','_1"CPVC 12 \ �4 \ \ PRESSURE GUAGE -Z \ n2 POTTER VSR-S \ WATERFLOW \ 1"DCVA AMES ALARM SWITCH e \ SERIES 2000B R-49 BLOWN INSULATION \ fT X X X X XXX X XxX X, X XXX XXXXXXX.X_X_XX_X X X XXX X X XY X��------ Y X XX X X X.Y -------------- ----------- --------- - -- - - - ------ -------- - --------- 0 . —_.. - ------ ._ —--- n 1 ! 1"EDDY-THREAD SCHED.30 TO METER AND SUPPLY 8' CLG. 8' CLG. 8' CLG. HALL HALL BATH MASTER , , \ \ 12 ' 3 n - FLOOR 1 3/4 x11 7/8n LVL BEAM B , RIM JOIST , , 9' CLG. 9' CLG. 9' CLG. B - RISER DETAIL FOYER DINING GREAT ROOM DECK , - - - - - - - - - - - - - - - - - - - - - - - , 1 , ' i -- -- 12"OF BATT OR R-38 INS.` BLOWN-IN INSULATION BRANCHLINE W/PIPE STRAP MEDIUM WEIGHT PLASTIC ! GRADED BACK BARRIER OVER LINE PIPING TO MAIN CRAWL I SPACE 1"x DROP (SEE PLAN) ` 2X RAMING 0 �GYP. BOARD F � w = a O 0w D_ E w - z � A - CROSS SECTION C - TYPICAL INSULATION COVER OFT 2 FT 4 FT 6 FT 8 FT 10 FT 12 FT NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-2 All piping and fittings to be CPUC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 21 All hangers to be CPVC Standoff type and located per NFPA 13D requirements. CROSS SECTION Atm DUAU Max.sprinkler spacing to be 16'x 16'w/8'-0"Off walls. PERMIT NO. All CPVC piping to be 1"w/Riser to be 1"black steel piping. W"'YATT 12080 SW Autumn View St CONTRACT NO. C15-685 Meets design requirements of NFPA 13D 2013 edition. All piping to be installed before insulation and protected with a medium weight plastic barrier(to be provided by others). FIRE PROTECTION, INC. TIGARD OREGON 97223 APPROVAL Riser to be connected to domestic water prior to hot water heater. 0 DRAWN BY A NISHIHARA Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 9095 S.W. Burnham plumber) Tigard, OR 97223 SCALE _ -01, (503) 684-2928 DATE 21 OCT 2015 STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 REVISED PFP 2 of 2 LOTTED