Plans (10) PLM2015 00196
JUN 18 2015
C"'y OF 11GARD
DUILl"C"DIVISION
GENERAL PLUMBING NOTES o
PLUMBING FIXTURE SCHEDULE PLUMBING SUPPLY LEGEND �-
GENERALPLUMBINGNOTES: WASTE&VENT LEGEND
1.ALL PLUMBING AND PRACTICE TO BE IN ACCORDANCE WITH 2014 OPSC. BASIS OF DESIGN
2.COMPLETE INSTALLATION OF PLUMBING SYSTEM TO CONFORM TO STATE BUILDING,ENERGY,FIRE,AND HEALTH CODES,AND TAG DESCRIPTION
MANUFACTURER MODEL COMMENTS ------- DOMESTIC COLD WATER
REGULATIONS ADOPTED BY LOCAL JURISDICTIONS. FD-1 FLOOR DRAIN WITH LEVELING STRAINER ZURN Z415BZ TRAP PRIME FROM NEAREST FIXTURE.SIZE PER LINE SIZE ____________ SANITARY SEWER
3.PLUMBING SYSTEMS AS SHOWN ARE SCHEMATIC IN NATURE AND ITEMS NOT SPECIFICALLY CALLED FOR OR SHOWN,BUT REQUIRED FORWBELOW GRADE �(n
LAV-1 ALL HUNG LAVATORY ZURN Z5340 INCLUDE ZURN Z81101-XL FAUCET,PROVIDE P-TRAP,TAIL PIECE,AND GRID DRAIN,TRU-BRO LAV GUARD;ZURN ZW1070XL MIXING VALVE
INSTALLATION FOR THE COMPLETE MECH.SHALL BE PROVIDED,AND ARE REQUIRED AS PART OF THE CONTRACT. MANUFACTURER'S ------- DOMESTIC HOT WATER
RECOMMENDATIONS AND INDUSTRY STANDARDS SHALLAPPLY. LAV-2 WALL HUNG LAVATORY GSI MCITY3111 INCLUDE ZURN Z81101-XL FAUCET,PROVIDE P-TRAP,TAIL PIECE,AND GRID DRAIN,TRU-BRO LAV GUARD;ZURN ZW1070XL MIXING VALVE SANITARY SEWER
4.PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE PLUMBING MS-1 MOP SERVICE BASIN ZURN Z1996-24 INCLUDE ZURN Z1996-SF FAUCET;PROVIDE HOSE AND HOSE HANGER,MOP HANGER,BUMPER GUARDS AND WALL GUARDS. _-------_ DOMESTIC HOT L
SYSTEMS AS INDICATED ON THE DRAWINGS,AS SPECIFIED,AND AS REQUIRED BY CODE. S-1 SINGLE BOWL SINK JUST MANUFACTURING SL-201 -A-GR INCLUDE ZURN Z812A4-XL FAUCET;PROVIDE TAILPIECE,BASKET STRAINER,AND P-TR WATER RECIRC ---------------- VENT PIPING W
S.CONTRACTOR RESPONSIBILITY TO VERIFY QUANTITIES. S-2 DOUBLE BOWL SINK JUST MANUFACTURING DL-2233-A-GR INCLUDE ZURN Z812A4-XL FAUCET;PROVIDE TAILPIECE,BASKET STRAINER,P-TRAP AND BUBBLER ZURN Z83600-XL
6.MAINTAIN A MINIMUM OF 36"OF GROUND COVER OVER ALL UNDERGROUND WATER MAINS AND A MINIMUM OF 12"OF GROUND WC-1 WATER CLOSET ZURN 25551 INCLUDE XURN 2595855-ELTOILET SEAT LP GAS C CONDENSATE PIPING OFFTr�
COVER OVER ALL UNDERGROUND SEWERS AND DRAINS. Co-Pr
7.UNLESS SPECIFICALLY NOTED OTHERWISE,ALL FIXTURES SHALL BE WHITE. - - - - FIRE SUPPRESSION
8.BURRED ENDS OF ALL PIPE AND TUBING SHALL BE REAMED TO THE FULL BORE OF THE PIPE. #1 8
9.PLUMBING SYSTEMS SHALL BE INSTALLED IN A MANNER CONFORMING TO THE 2014 OPSC AND THE MANUFACTURER'S �' -- REFRIGERANT R-410
RECOMMENDATIONS. IN INSTANCES WHERE THE CODE AND THE MANUFACTURER'S INSTRUCTIONS CONFLICT,THE MORE STRINGENT
PROVISIONS SHALL PREVAIL. S
10.NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE OR MASONRY. NO STRUCTURAL MEMBER SHALL BE SERIOUSLY WEAKENED OR 0 ELBOW DOWN _ TEE OUTLET �P
IMPAIRED BY CUTTING,NOTCHING OR OTHERWISE. DOWN
11.NO WATER,SOIL,OR WASTE PIPE SHALL BE INSTALLED OR PERMITTED OUTSIDE A BUILDING OR IN AN EXTERIOR WALL UNLESS,WHERE WATER HEATER SCHEDULE ELBOW UP -o- TEE OUTLET UP
NECESSARY,ADEQUATE PROVISION IS MADE TO PROTECT SUCH PIPE FROM FREEZING.
12.ALL PIPE PENETRATING FLOOR/CEILING ASSEMBLIES AND FIRE-RESISTANCE RATED WALLS OR PARTITIONS SHALL BE PROTECTED WITH THE ELEMENT ELECTRICAL J
REQUIREMENTS OF THE BUILDING CODE. MARK MANUFACTURER MODEL 5TORAGE CAP. WATTAGE V/O/HZ AMPS WEIGHT(LBS) WATER HAMMER f
13.PIPING IN THE GROUND SHALL BE LAID ON A FIRM BED FOR ITS ENTIRE LENGTH. WHERE SUPPORT IS OTHERWISE PROVIDED,IT SHALL BE WH-1 JA.O.SMITH I DRE-53-9 150 GAL (3)1000 208/1/60 125 1265 ARRESTOR '
ACCEPTABLE TO THE ADMINISTRATIVE AUTHORITY. ��CW �� SINCE, .1969.
14.HANGERS AND ANCHORS SHALL BE OF SUFFICIENT STRENGTH TO SUPPORT THE WEIGHT OF THE PIPE AND ITS CONTENTS. PIPING SHALL
BE ISOLATED FROM INCOMPATIBLE MATERIALS. QR • ,
15.JOINTS IN COPPER TUBING SHALL BE MADE BY THE APPROPRIATE USE OF APPROVED COPPER OR COPPER ALLOY FITTINGS. SURFACES TO ? A--
BE JOINED BY SOLDERING SHALL BE CLEANED BRIGHT BY MANUAL OR MECHANICAL MEANS.THE JOINTS SHALL BE PROPERLY FLUXED WITH iim
lrov
AN APPROVED TYPE FLUX,AND MADE UP WITH APPROVED SOLDER. ALL SOLDER AND FLUXES SHALL BY MANUFACTURED TO APPROVED OTCA `ICS_ D
PUMP SCHEDULE
16.SOLDERS AND FLUXES WITH A LEAD CONTENT WHICH EXCEEDS TWO-TENTHS(0.20)OF ONE(1)PERCENT ARE PROHIBITED IN PIPING ' �9'rCh�rcT�,rriyfiW��Ca��
SYSTEMS USED TO CONVEY POTABLE WATER. ELECTRICAL
17.JOINTS FROM COPPER TUBING TO THREADED PIPE SHALL BE MADE BY THE USE OF BRASS ADAPTER FITTINGS. TAG DESCRIPTION MANUFACTURER MODEL V/QS/HZ WATTS FLA RPM WEIGHT NOTES ��i-/
18.APPROVED UNIONS MY BE USED IN DRAINAGE WORK WHEN ACCESSIBLY LOCATED IN THE TRAP SEAL OR BETWEEN A FIXTURE AND ITS CP-1 CIRULATION PUMP BELL Sc GOSSETT N8F-9U/LW 115/1/60 41 0.40 2800 9.3 LBS 1,2 8 � �i*`' ME �fAUA Rip PRO
TRAP;IN THE VENT SYSTEM,EXCEPT UNDERGROUND OR IN WET VENTS;AT ANY POINT IN THE WATER SUPPLY SYSTEM.
19.WHEN CONNECTING PLASTIC PIPE TO OTHER TYPES OF PIPING USE ONLY APPROVED TYPES OF FITTINGS AND ADAPTERS DESIGNED FOR NOTES: �����NGINFFRSS'/��
THE SPECIFIC TRANSITION INTENDED. 1. INCLUDE AUTOMATIC TIMER KIT(113210) *001 d _2 71072PE r
2. INCLUDE AQUASTAT PER LINE SIZE. O�3
TRAPSAND INTERCEPTOR NOTES:
1.EACH PLUMBING FIXTURE,EXCEPTING THOSE HAVING INTEGRAL TRAPS,SHALL BE SEPARATELY TRAPPED BY AN APPROVED TYPE I
r v OREGON
WATERSEAL TRAP. NOT MORE THAN ONE(1)TRAP SHALL BE PERMITTED ON A TRAP ARM.
2.THE VERTICAL DISTANCE BETWEEN A FIXTURE OUTLET AND THE TRAP WEIR SHALL BE AS SHORT AS PRACTICABLE,BUT IN NO CASE I ` �0 q Y 14 26�pL�
SHALL THE TAILPIECE FROM ANY FIXTURE EXCEED TWENTY-FOUR(24)INCHES IN LENGTH. 1V Rq Y M 0 ND
3.EACH PLUMBING FIXTURE TRAP,EXCEPT AS OTHERWISE PROVIDED IN THE DSPC,SHALL BE PROTECTED AGAINST SIPHONAGE AND BACK EXPIRES: 6302016
PRESSURE,AND AIR CIRCULATION ASSURED THROUGHOUT ALL PARTS OF THE DRAINAGE SYSTEM BY MEANS OF A VENT PIPE.
4.THE VENT PIPE OPENING FROM A SOIL OR WASTE PIPE,EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES,SHALL NOT BE BELOW THE
WEIR OF THE TRAP.
S.THE TRAP SHALL BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED.
SUPPLY PIPING NOTES:
1.ALL WATER SUPPLY LINES SHALL BE TYPE L COPPER MIN.
2.ALL HOT WATER LINES SHALL HAVE 1"MIN.INSULATION.COLD WATER SHALL HAVE 1/2"MIN.INSULATION.
3.UNLESS OTHERWISE NOTED,ALL DOMESTIC COLD AND HOT WATER PIPING SHALL BE MINIMUM 1/2"SIZE.
4.ALL STOPS,ESCUTCHEON,P-TRAPS,OR OTHER ACCESSORIES TO BE STAINLESS STEEL OR CHROME PLATED WHERE EXPOSED,PLASTIC TRAPS Uj
ALLOWED IN ALL OTHER AREAS..
5.INSTALL PIPING SO THAT ALL VALVES,STRAINERS,UNIONS,TRAPS,FLANGES,AND OTHER APPURTENANCES REQUIRING ACCESS ARE
ACCESSIBLE.
6.WHERE DOMESTIC COLD AND HOT WATER PIPING DROPS INTO A PIPE CHASE,THE SIZE SHOWN FOR THE PIPE DROPS SHALL BE USED TO
THE LAST FIXTURE.
7.UNIONS AND/OR FLANGES SHALL BE INSTALLED AT EACH PIECE OF EQUIPMENT,IN BYPASSES,TO PERMIT DISASSEMBLY FOR
ALTERATION AND REPAIRS.
8.ALL VALVES IN THE WATER LINES TO BE BRASS.
9.ALL VALVES SHALL BE ADJUSTED FOR SMOOTH AND EASY OPERATION.
10.ALL VALVES(EXCEPT CONTROL VALVES)AND STRAINERS SHALL BE FULL SIZE OF PIPE BEFORE REDUCING SIZE TO MAKE CONNECTIONS
TO EQUIPMENT AND CONTROLS.
11.PROVIDE ALL PLUMBING FIXTURES AND EQUIPMENT WITH ACCESSIBLE STOPS. O
12.ALL BALANCING VALVES AND BUTTERFLY VALVES SHALL BE PROVIDED WITH POSITION INDICATORS AND MAXIMUM ADJUSTABLE
STOPS(MEMORY STOPS).
13.ALL VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN SERVICE WHEN EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF VALVE
IS REMOVED.
14. WHEN ROUTING PIPE THROUGH FRAMING,PROVIDE SEPARATE PENETRATION FOR EACH PIPE. MULTIPLE PIPES THROUGH SINGLE
PENETRATION IS NOTALLOWED.
WASTE AND VENT PIPING NOTES: Uj V
1.RUN ALL WASTE PIPING 3"AND BELOW WITH 2%MINIMUM GRADE 7
2.ELEVATIONS AS SHOWN ON THE DRAWINGS ARE TO THE CENTERLINE OF ALL PRESSURE PIPING,AND TO THE INVERT OF ALL GRAVITY L
PIPING.
3.ADJUST SEWER INVERTS TO KEEPTOPSOF PIPE IN LINE WHERE PIPE SIZE CHANGES. Q
4.ALL ABOVE GROUND DRAIN WASTE AND VENT PIPING SHALL BE CAST IRON.
5.ALL FLOOR DRAINS SHALL HAVE AUTOMATIC TRAP PRIMING DEVICES.
6.ALL CLEANOUTS SHALL BE FULL SIZE OF PIPE FOR PIPE SIZES 6 INCHES AND SMALLER,AND SHALL BE 6 INCHES FOR PIPE SIZES LARGER
THAN 6 INCHES. U.
7.ALL VTR's AS SPECIFIED ARE MIN.SIZE TO ROOF. ALL ROOF PENETRATIONS TO BE 3"MIN.
8.ALL VTR'sTO PROTRUDE 12"MIN. O
9.FITTINGSINGS USED FOR DRAINAGE SHALL BE OF THE DRAINAGE TYPE,HAVE A SMOOTH INTERIOR WATERWAY,AND BE CONSTRUCTED SO
AS TO ALLOW ONE FOURTH(1/4)INCH PER FOOT GRADE. �/`
10.CLEANOUTS SHALL BE DESIGNED TO BE GAS AND WATERTIGHT WITHOUT THE USE OF ANY GASKET,PACKING,OR WASHER. 1(.71_,1
11.CHANGES IN DIRECTION OF VENT PIPING SHALL BE MADE BY THE APPROPRIATE USE OF APPROVED FITTINGS AND NO SUCH PIPE SHALL
BE STRAINED OR BENT. BURRED ENDS SHALL BE REAMED TO THE FULL BORE OF THE PIPE.
12.INDIRECT WASTE PIPES EXCLUDING 5'BUT LESS THAN 15'IN LENGTH SHALL BE DIRECTLY TRAPPED,BUT SHALL NEED NOT BE VENTED.
TRAPS REQUIRING VENTING SHALL EXTEND SEPARATELY TO THE OUTSIDE AIR.
13.NO MORE THAN 1/3 OF TOTAL PERMITTED VENT LENGTH PER TABLE 7-5 OF CURRENT OPSC.CAN BE INSTALLED IN HORIZONTAL Ujr
POSITION UNLESS SIZE IS INCREASED BY ONE PIPE SIZE. v
O
Ce
Ua
O w
U
Q j
U '-'
LL z
z 0
LU
0
Q z
W w
06un
-' z J
oC oo (n 0 C)
W W m W
LU zi 0 >- U
0 a z cn cn
Issued For SD: 03/17/11
Issued For DD:
Issued For Permit: 05/05/15
Issued For Construction:
Revision Number Revision Date
1 6-9-15
Plot Date 6/9/2015 10:15:27 AM
J,
r ife Of Your Building PO - 01
Wt
ICU
1 2 3 4 5
-
•51NC1. ` .19G3•
; - r
f
rh �q
T,
,
t i
11'777 re .
i I � I
i:. E-'- `� ;I 'I _ , it i D Mo
p&
0 cw j _ j 1/2 0 CW r�- ;\ 1/2^0 cw ! 1/2"0 CW L_' .: . 1/2"0 CW- -' _i/zt'0 cw •: 1/z„0 cw-- .--.- 1/z+,m cyd i ��' ��R� FFss
1 - - - - I i L 1- �o
1/2"0 HW 1/2"0 HW 1/2'0 HW VESTIBULE ;' 1/2"0 HW 1/2^0 HW 1/2"0 HW 1/2"0 HW 1/2"0 HW 1/2'0 HW
1 71072PE r
27 � 5-1
f
- - - 1/2°0 cw -
- 1/2t'0 CW -I - - 1 1/2"0 CW -'I 11/2„0 I 2,0 p . 2.0 - 2 0 I 2"0 CW
- r I I 1 4' v OREGON
IG _ Cz r --J --------- - ------- I ------ ----- I--------- ------ - 1 .., --------- I --- 2"o CW --- I --1 L 9 Y o4ti ��Q
i. L 14
_ . II - ONp
-- ------
ll ' _ ___ �— I AYM
0
4 0 HW EXAM EXPIRES: 6/302016
I 11/4'0 HW 11/4'0 HW 1 1/4"0 HW 1 1/4"0 HW 1"0 HW 1"0 HW 1"0 HW 1'
I'
j ISO - I :_ � .. I I u, • •
�i IT OFFICE I I EXAM" EXAM` I EXA EXAM; `' 1
51 30 I 2 2 26 19 18 j l i
-- —.r I I I .�... �..
I
---
-- -- 11/2"0 cw I I I - -
i I ��;; I
HALL
11/4^0 HW 20 I .
1^0 CW I 1/2"0 HW ,
2"0 CW-
1 2"0 HW - - .. i
/ z � l �I I -- 3/4t0HWI _
---
`I
,; � �f- --�--,.._• _. _ ,I � �1 z°0Hw ro1LE�f `� „_,.-.-•'� --`__ >> I
TOILET! f a 7 / '�---_�-- /
, 25 � i
y
r
1/2"0 \\t::: I..
CW.
K
ILET / 0 I
{ / }
LO�1NFaE 46 �� __ ..------ ( r"�� WC-1 LAV 2 1/2'0 CW
' r � r
_ _ - I
_.. _
-49 ---' - 1/210 CW I 5 1 ; ;I saw �� \ I I 1/2'0 CwDo i/2tt0 HW I / I
c, o
00
I c r 1t J �� ` —- EXAM { z
3/4"0 CW
! - I
C WC 1 O ! __^__ II 1� 1 1' lr� 1 1 0 CW X3/4 0 CW a x a 1/2.10 CW f ��� \ I r --------
J
- - ---'
L o o 1 CARE TEAM 1/2"0 HW ° -I I \ l ILU
I i
1/2"0 HW } 24 1/2"o CW
' ' �1, '�\�`7,/ I S-2 \\\✓' _ '� '--.-. _ I S-1 _..-- --
I
11/4' CW I
1/2"0 CW
/ 0 ; I !
1/2"0 CW DIRTY r -
11/4"0 HW 23 1 2" G1N
• / 0
1'
SERVER
1/2"0 CW
r STAFF HALL 5 1/2"0 HW
LJ
J I EXAM i ♦ Y %' i a� _ S 1 -� / 1 \ v� / I, - - 3/4"0 HW
j
MED GPREP COPY
J 111/4"0 HW 32 I d� �1 1/2'0 CW I _ w -
- 11/4"0 I I 1/2"0 CW
I i/z"0 H EXAM I I
Cw -- ��'�
_ \
I
I
1/2"0 HWC13
L ca
WH-1 C r- ttll 1/2"0 HW
1 1/4 0 CWS � , LAV-1 '� \� I I I 1 O I
I 1/2"0 HW , �.-+,- -:1/2"OHW.-.
- ----- I 1 d
1/2"0 CW
GAS P^ BREAK t 1/2"0 HW TOILET \\QWC-1 ��1 J \J �11/2"0 HW—r 6
r? I 11/4"0 HW I
CP-1 9 -
--1 v
METER --- _"Q
1/2 0 HW \
�J gg 2" f� l 1 I �, � 1 HALL 4 r' I / \ I J \ /
P 1/ 0 CW 34 % / i I ' I I �1/2,0 Hw.1
l l "�?, i' PHONE 1 2"0 CW
® - -
f
L_
\ i
1
— — — a , BUILDING.SERVICES I 5 1 O ay �. \' — — 6
EXAM LU
S-1 I I I
HALL
F 33 �
\ , .. k�a; ~ \ \\ ✓ ' 'I 11 d 12
ECEPTION x
1/2^0 CW 1/2"0 HW \
1
- - I
I o 'K -
STORAGE I r':-, »,.....
43 1 ---- I ]E P !
s \� 2 0 CW
,
,
LL,
I �01 10 oSTA�42�d
u
,
I
� 1 '
it `� - •, ,: , i n " .n
,
O
,
� --.- ' _ I BEHAVIORAL HFA.kM--._------ NUTRITIONIST __ . SIfEMANAGER VESTIBULE- _ VIJAITING' t BEHAVIORAL HEALTH TRUIGE CARE MANAGE
/ 1
j � Q
40----_ F a ---:r'*� ----' 07 I 08 09 _r.
�- PHYSICIAN LOUNGE �____.----_` CEO C
-- ---- 39 52 37 O3 - - ia' � F ..
� ILLL
1
\ , o ' 1 i ( 1 - ,17.:x, \�_..; 2"O CW
_ i - -,
- I \
it
�G � _ i �1 � �j � � I p� z
t� (n
O V
,
{ LL
CONNECTTO J^
EXISTING 2"CW
ce-
I--I tJ D
1 2 3 4 5 LL a U)
Issued For SD: 03/17/11
Issued For DD:
Issued For Permit: 05/05/15
Issued For Construction:
Revision Number Revision Date
Plot Date 6/9/2015 10:15:30 AM
Aff
FIRST FLOOR PLUMBING SUPPLY PLAN P 1 _ O 1
1/4"= 1'-0" ife Of Your Building
a
O�o
L
is
�8
1 2 3 4 5
SINCE-
---- -_ -..-._._
__ .19fi9•
i
i
,
yf_I_..�---.-_--._---._•-',-I.-.----.-_--.jiIj((,I�rF}1-i.I Ii'>�--,»�I�wCk+'-l.�-_.-1.q'`c,I,\'J Ij-,\r\A_�-\/•—�-/_i1i\U4�I-rt
+-•--_—w------_.—.--4-7---t—'-o•--.-"!—�:sr7
t\1')-----..rI_-' �'r—\!`m♦�'..—..-♦1'♦-a-��r--1.-..-.---♦--
♦-�-
�M—`♦
2.,."-rI..`.w.-,..-•.--/...,.-.
_
9--•--a
-----
--
'
-.
"O L♦FAD♦-./-1\gy•\1`^.p 1 I
/
.-_. ♦_—k-:— ,}-I,/..I'
-
---
I•
»__\-._,.»._-(_-�_��-'-♦_r`_�_ _♦—�-L—_♦A-V.--._2-♦-♦-I_-�--♦
„•=d'�a�
S-1�.� .J,.,[RI•,�I I r«V,-,.J(I>.'-�'A-.w_-.>Ii�>T.
,.I
-\.--/cIi\���•
F�E`.,\i\•`�/�!.�.�,.aiI
_�v:_IItI:\�\..��:•.l a
\..,
-idXu—
1�
-�♦-♦/-/`y j 1iII
.lII
.•!'.tI.._ 6-p,- ,
I�
-.._._
._.
_.I
_.--_..-_.r_•-
.--."-.
,-
0,•:,.,.m•.-_.w...,,
_—.-..._..._„_--•.-.'_s---
--
I."
-'-�-�
----�i
_
-
,i
/
I_�7-1l{I;tIjIiIII�IiIfI.
.
-
_
�-S---
1
-1
--
IijI
IIhIj!.ii
-
OO(a1QV9
�
re,Su
E
!1D GRn
(T-
CS 1¢ 2"0 71072P2�
E2"0 S 1 - O 1 2"0 2110 2"0
2"0 2"0 - - - - -20
S-1 VESTIBULE
" 11 2"01/ ORE
WCO 11/2„0 oyyl4------------------
--------------- /---------------- ----- ------------ -------------------- 11/2"o 11/2„6
0 0 0 \ - 11/20 - J 1 { YMONO12.0 ...... ---- - --------------- -+IT OFFICE 1 ---------
ONF 51 EXAM EXAM EXAM EXPIRES: 6I0,
N
f0
61=1115EXAM EXAM EXAM EXAM EXAM EXAM
2 26 17 1 30 2 11/2"0 11/2"0 11/2"0
2"0 - - --- I Uj
HALL 2--0
7207
11/2"0
3--0
--_-- _. _.. ---- .. . ------
TOILET
TOILET 212
T(�-Fl --
25 "02 0 11/2' LAV-2 2
2 - ----- ----3"0(E)VTR t 30(EjVT -------- ----- 3i0(E)�R 11/2 0- -
2"0 11/2 S-1 ------------------------------
------------- =-- ----- ----- -------
2'
-----
2
2 0'2 4"0 IXISTING 4"O IXISTIN +3
sWCD 2
CAR TEAM
Uj
T
223"0I - 31 5
SERVERLi
DIR745
T-0
1 1/2.0 23
20 �"0
--------- _ -------
2V
--- 2"0HALL I STAFF COPY
MED PREP F 1o7
2--0 I 11/ 01
1 , —1
( RWLUTO EX WV-1
ROOF DRAIN
- EXAM - •
2"0
F 32
WCORWLUPTO
UJ
BREAK
WILDING SERVICES DRAIN48 11J2"0
VETE 11/2"0 2"0EXISTING ROOF
11/2"0
HALL 6 E
? 11/2"01 � 34
F 047
WCO
CED
2"0
♦ • JED
--------- /2 0 - - - 2"0- ---- HALL S-1
Uj
EXAM
---I 1/2"0 33 12— E
CE fQN
STORAGE
EP43 JLL
jEP
WRAP EXISTING PVC ROOF WRAP EXISTING PVC ROOFSTAFF DRAINS WITH PLENUMDRAINS WITH PLENUM RATED INSULATION INSULATION 4"0 EXISTING
LU
PHYSICIAN LOUNGE
o o
SITE MANAGER 02
VESTIBULE CARE MANAGERS
NUTRITIONIST
BEHAVIORAL HEALTH BEHAVIORAL HE �oI
�
(OLfz
UJ UJ D
CEO COO 09
TRIAGE
52
39
08
I10 -Z�
io W
C',
Ln Ul
4"EXISTING WASTE
LINE.SEE CIVIL FOR �l
CONTINUATION OF1 2 3 4 PIPING 5 Lm
Issued For SD: 03/17/1
1
Issued For DD:
Issue For Permit: 05/05/1
5
Issued For Construction:
Revision Number Revision Date
1 6-9-15
Plot Date 6/9/2015 10:15:32 A
M
FIRST FLOOR PLUMBING WASTE & VENT PLAN AN
pi - 11
1/4" V-0" Ife f Your Building" -
tr Ii
'�—LAVATORY
`QOM
CHROME PLATED BRASS V
TAILPIECE WITH 1/2"0 BRANCH ,
COMPRESSION COUPLING
18GAUGEROUND
�-ESCHUTCHEON GALVANIZED STEEL L
1ti 4
If'�• '1ti
1I CLEANOUTTEE
1 x� I ACCESS COVER
S-1 i gg
.i 8
FINISHED WALL
S-1 i ti o \\ � CLEANOUT PIPE
i 1/2"STAINLESS STEEL
13'g(E)VTR I I1/��` BRAIDED HOSE
1/2"0 TYPE"M"COPPER .51NCE•
PIPE TO FLOOR DRAIN
1I/ S-1 1 1 4
f c°
TAILPIECE TRAP PRIMER WALL CLEANOUT �,,9 �C�10 ,fi'
f-----11/2"p----�� S-1 � i ` � �rrhyhture,5urvM'tM1,\"ria
I I I I
1
S-1 i S-1
FINISH FLOOR LINE
SCORATED SECURED �P�D PROFFS
,1 6 NICKEL BRONZE TOP CONCRETE RING COLD WATER HEADER
i`�'K,n i ^ AROUND HOUSING
S-1 710 2P �<
,'� �-)
�' ... "d _ •O ----------- --- ---- -- --------------------------
Ite
BALL VALVE WHEN SPECIFIED /
a - PRES
rj
�.'� i .L i i i r' .' i °.`..a, , ° ,•q •° 46. ;d 4
° - ACCESS ------- ACTIVATED PRIME VALVE 990 ORE
�"��1�\�
%I I , ------- — N O
PANEL -- ----- R Yt
1'I i i LAV-2 i ! WC-1 I i SOIL----
1F ----- ''l A l MONO
3"4(E)VTR, I D i 1 ,✓
I may.' i LAV-2 -�``` PROVIDE EXPIRES: 00/2016
5-2 SMITH#9329 SUPPORT J.R.SMITH 44020 SERIES,DUCO DISTRIBUTION UNIT
1 �/ (AS NEEDED) CAST IRON BODY CLEANOUT WITH WHEN SERVING
S-1 `\gym i FD-1 i G /// MULTIPLE FIXTURES
------WC-1.� -------- y S i TAIL PIECE
\ i FLASHING FLANGE
SMITH#9502 NEOPRENE GASKET I I
1/8 BEND z L-------- --------i Uj
C/L
FINISHED FLOOR ,1
I I "Y"BRANCH,SIZE AS REQUIRED I FLOOR DRAIN/
S-1 �� i 3• i \ (AT END OF RUN USE LONG SWEEP FLOOR SINK
90°ELL)
I I
-�-
3"0(E)VTR -----
11/„
1/2"L OR K SOFT
FD 1 COPPER(SLEEVED) TAIL PIECE
I I
1 �
1 I
111S_1
LAV-1i INTERIOR FLOOR CLEANOUT IWR W/TRAP PRIMER =
S-1
WC-11 -=
r
fD-1�
6 I I
1 I
1 W
WCO 1 5-1
Z
FLOOR DRAIN STRAINER
CERAMIC TILE AND SETTING BED THREADED ROD;
FINISHED FLOOR SURFACE ATTACH TO STRUCTURE.
WATERPROOF MEMBRANE Q
I i SLOPE TO DRAIN � PIPE HANGER GALV.METAL SHIELD,AS
1 --�- E-- NOTED IN SPECS.,BETWEEN
mmmm mm e
HANGER&INSULATION,UP
MS-1 2° ' ' TO CENTERLINE OF PIPE. U. P-.'
' INSULATION AS SHOWN
S-2 L ° a° a�, , .Q,; ON PLANS&NOTED IN RIGID INSULATION
SPECIFICATIONS.
6„ !
°
`CONCRETE FLOOR SLAB
COVERING AS REQUIRED W
LEAD AND OAKUM OR V
NEOPRENE GASKET CLAMP PAN TIGHTLY INTO DRAIN COLLAR
6"MIN. O
DRAIN BODY POURED IN PLACE PIPE AS SHOWN
ON PLANS 10"MIN, u
U O
WASTE AND VENT ISOMETRIC FLOOR DRAIN DETAIL INSULATED PIPE HANGER 0 w
7 V) oC
NOTE: CODED NOTES
EXTERNAL GAUGE TAPS ON PIPES Oi COLD WATER SERVICE,SIZE
SHALL NOT BE REQUIRED WHEN AS SHOWN ON PLANS
PUMP IS PROVIDED WITH
FLANGE GAUGE CONNECTOR. O CHECK VALVE SIZE TO PIPE SIZE WALL
PRESSURE GAUGE O3 POTABLE WATER EXPANSION TANK, U.3
INSTALL PER MFR.RECOMMENDATION 10 13 1-� O
® AND STATE&LOCAL CODES.WATTS J Z
DET-12-M1 uu
1
IN-UNE PUMP Oa UNION,DIELECTRIC IF REQ'D 12 SECURE CHANNEL TO WALL Uj
STRUCTURE AS REQUIRED`TYP. Uj
` OS WATER HEATER,SEE SCHEDULE CW
0 2"DEEP GALVANIZED STEEL DRAIN PAN 8 2 14 Q C Z O WITH SOLDERED SEAMS AND 2 COATS OF AT WATER HEATER AND STORAGE TANKS
RUST INHIBITIVE PAINT 15 PROVED"SPACE MAKER"BRAND SEISMIC LONNA
RESTRAINT SYSTEM(OR APPROVED EQUAL).
O MOUNT ON 2"RIGID INSULATION SYSTEM TO MEET REQUIREMENTS FOR ZONE 4 Q
SEISMIC INSTALLATIONS.
1/4"PIPE OR TUBING a 4 UJQn1'�
O BALL VALVE w ((V
Oio ELECTRICAL CONNECTION a TANK HEIGHT NO.OF a `
9 SIZE ABOVEFLOOR STRAPS LOCATION 1
11 SEISMIC STRAP TO WALL PER UPC BETWEEN TOP 1/3 ADN
SYSTEM PIPING 0 4 66 GALLONS OR LESS 12"OR LESS 1 1/2 OF TANK
12 120°F WATER SERVICE LOOP,SIZE AS
1/4"PET COCK(TYP) SHOWN ON PLANS I TOP-IN TOP 1/3 OF TANK
13 TO COLD WATER SERVICE.SIZE ASD 11 66 GALLONS OR LESS MORE THAN 12" 2 BOTTOM-3"ABOVE OR BELOW
SHOWN ON PLANS 6 ACCESS PANEL
DOMESTIC HOTWATER PUMP
8 14 CIRCULATOR PUMP,W/TIMER SET W Ems'-/� TOP-IN TOP 1/3 OF TANK
3"= 1'-0" TO OPEATE FROM 7 AM TO 7 PM- 66 TO 100 GALLONS 12"OR LESS 2 BOTTOM-3"ABOVE OR BELOW
VERIFY W/OWNER v
15 120°F WATER RETURN,SIZE AS ACCESS PANEL
TOP-IN TOP 1/3 OF TANK
O SHOWN ON PLANS 66 TO 100 GALLONS MORE THAN 12" 3 BOTTOM-3"BELOW ACCESS PANEL F-11
MIDDLE-CENTER OF TANK
ELEC. WATER HEATER W/RECIRC LINE WATER HEATER BRACING
10 111= 11-0t, UJ
CL in
Issued For SD: 03/17/11
Issued For DD:
Issued For Permit: 05/05/15
Issued For Construction:
Revision Number I Revision Date
Plot Date 6/9/2015 10:15:33 AM
tr
P201
I ife Of Your Buildin —
g