Plans (10) PS2015 00155 � K L3 ao u.) a RECEIVED O O OCT 5 2015 U'u') CITY OF TIGARD BUILDING DIVISION rj � � Q a u w S vo m LIN N `N 3r co 2 1 wlw rrh� t CW/)ujc'� O Vl w� U OCOLU m w D cn 1tn N MASTERCARE 380 Q�w} w 3 m w L U J wM C W G a FIRE ALARM SYSTEMT W m 'I w m a w 5 _m N d m Y7" SITE INSTALLER W DRAWING INDEX E R DWG# DESCRIPTION LINCOLN 1 CAPITOL ELECTRIC FA-001 COVER SHEET FA-002 GENERAL INFORMATION o 10300 SW GREENBURG RD 11401 NE MARX ST FA-101 DEVICE PLACEMENT PLAN, CALCULATIONS & PANEL DETAIL s 6 TIGARDa O R 97223 PORTLAND O R 97220 FA-701 WIRING TYPICALS a g a m a m 4 w 3 U 3 a OWNER0 o SHORENSTEIN REALTY SERVICES o 0 10220 SW GREENBURG ROAD a T PORTLAND , OR 97223 a 4 T ` g i °r° o Q I I cc ff"OF'nGARD OO h M o It .VM?VV l3 FOR CODIS cowumcmcn Aprv►* t t_ W II OTOh 0 Permit#: 2-n -cotQ Address: Lam- r— Z cq Ljj 04 $ixlte#: 7EW ham- w lBys Data J w G o W iii �co c� � � � O 8 OFFICE COPY � cn � o < Q Q w � i U- 7 H b � w � � G d O A m � Q G � I C�C Z O 0r C cn j Z S O WC Q w W E N Z O U � a. D � c m Q ~ 6305 SW ROSEWOOD ST, SUITE A LAKE OSWEGO, OR 97035 W Cl Q � � a co s Lu PHONE: 503-683-9000 DWN BY: J.JOHNSON SERVICE: 503-683-900 i CHEC ED BY J.JOHNSON � FAX: 503-675-6521 g ISSUE DATE: 9/18/15 ellJOB#: PROJECT#: 448:987874101 zg SIMPLEXGRINNELL© 2015 w �"M SYSTEM: aferA. m� er. Tyco. FIRE ALARM SYSTEM i SHEET: f � SAL ES REPRESENTA TI VE SCHE,DUL ING DRA WINGS PREPARED BY COVER SHEET N BRYAN ADAMS FAITH KASKE JEFF JOHNSON 503-683-9000 503-683-9000 N I C ET LEVEL III #121846 0 N bradams simplex rinnell.Com fkaske sig lex rinnell.Com _ zo a 9 p 9 FA 001 z x a rai a jai SYSTEM DESCRIPTION SCOPE OF WORK SYMBOL KEY GENERAL NOTES / � oN � c UW OCCUPANCY TYPE: B BUSINESS GROUP w 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF 0 CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES a� SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. ui SPRINKLER PROTECTION: BUILDING !S FULLY SPRINKLED 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT MODIFY EXISTING FIRE ALARM SYSTEM: RELOCATE EXISTING DEVICES AS SHOWN ON DRAWINGS. FIRE ALARM SYMBOLS LEGEND i' TO IMPAIR THE CONSTRUCTION SCHEDULE. �� i--o 1 3 AS REQUIRED CTOR ITORESPONSIBLE ACCOMMODATE THE RELOCING ATION OF�EQUIPMENTAPPROVAL AND/OR DEVICES CWHIC�HYARE ADJUSTMENTS IN CIRCUITING DESIGN IS FOR FIRE ALARM NOTIFICATION IN THE OUTLINED AREA OF WORK. � � oo AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. ALL NEW WIRING TO BE CLASS B. SYMBOL DESCRIPTION M O D E L BAC K B 0 X c0 . W 6,C90 I 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR owe NAC EXTENDER PANEL �c•- INSTALLATION. THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE NAC # DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELL `-' 0u 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TOW / 6.2AH BATTERY SET SIMPLEX 2081-9272 n o Y it BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. o 0 Cu � PERMANENTLY IDENTIFIED AT THE ARERCUIT CONTROL' THE nALARMON F THE CONTROL CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE F] MANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP 1 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. 3 SMOKE SENSOR BASE SIMPLEX 4098-9714 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. / 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. QM DOOR HOLDER BY OTHERS 10. THE ARE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. g 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FRCP ENCLOSURE IN ACCORDANCE WITH RI RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8' DEEP W/TWO GANG COVER MANUFACTURERS INSTRUCTIONS AND NEC. TIRE ALARM APPLICABLE CODTS & STANDARDS 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. ® WALL MOUNT MULTI-CANDELA STROBE ONLY WHITE SIMPLEX 4906-9103 4" SQUARE BOX 1 1/2" DEEP a 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE # =CANDELA RATING FPLP. 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN OREGON FIRE CODE, 2014 EDITION VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. ®C CEILING MOUNT MULTI-CANDELA V/0 WHITE SIMPLEX 4906-9104 HANDY BOX 1 1/2" DEEP 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET # =CANDELA RATING LOCATIONS. OREGON MECHANICAL SPECIALTY CODE, 2014 EDITION 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. OREGON ELECTRICAL SPECIALTY CODE, 2011 EDITION CEILING MOUNT MULTI-CANDELA A/V WHITE SIMPLEX 4906-9130 4" SQUARE BOX 1 1/2" DEEP 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. G # =CANDELA RATING 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. NATIONAL FIRE ALARM CODE {NEPA 72), 2013 EDITION END-OF-LINE RESISTOR 3.3K (EOL) SIMPLE( 4081-9002 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 " 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. EOLR SUPPLIED BY SIMPLEXGRINNELL 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 23. ES11NG CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING END-OF-UNE RESISTOR 10K (EOL) SIMPLEX 4081-9008 CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. NOTE: EXISTING D£V!C£S SHOWN SHADED FOR REFERENCE. JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. WIRE SCHEDULE ABBREVIATIONS LEGEND AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM RISER DIAGRAM RL = RELOCATED DEVICE N/A = NOT APPLICABLE RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER A NDU = NETWORK DISPLAY UNIT p FIRE ALARM WIRE LIST WP = WEATHERPROOF NEC = NATIONAL ELECTRICAL CODE GENERAL NOTES: CIRCUIT DESCRIPTION RISER RATED: FPLR ISINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION V VISUAL/SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAJGE 454719ARE H = HIGH HUMIDITY NIC = NOT IN CONTRACT 1. DEVICES SHOWN ARE TYPICAL SEE FLOOR PIAN v AREA=0.0380 SQ. INCH AREA=0.p333 SQ. INCH AFF _ ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT FOR QUANTITY AND LOCATION. SPARE N31 2 CONDUCTOR 14 AWG AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE RL SOLID ANIXTER PART NUMBER ;{2) #14 AWG ANIXTER PART NUMBER A� = ALARM PAP _ PRE-ACTION PANEL 2. WIRING SHALL NEPA 70, ARTICLE {RL) V v V N30 NAC$ - _ FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACHY: FA-1402C-1-2N-03760, of ( ): ANN ANNUNCIATOR SCC STATUS COMMAND CENTER EDLR �` CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA BMS = BUILDING MANAGEMENT SYSTEM SLC = SIGNALING LINE CIRCUIT 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. C c c c C 9) v4009 W 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * CBC = CALIFORNIA BUILDING CODE SMK = SMOKE o r N29 a w 3�4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * CD = (eg. 15CD) CANDELA SUPV = SUPERVISORY KEYED NOTES: C C ELECTRICAL RM 1 0.34 SQ INCH * 2" 1.34 SQ INChi * CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER v EXISTING NAC CIRCUIT N28 IS TO BE CUT IN HALF do �N28) * 40% FILL PER N.E.C. DET = DETECTOR TRBL = TROUBLE O TERMINATED AS SHOWN ON FA-101. 10K END OF UNE EOLR N28 h- RESISTOR IS REQUIRED FOR SUPERVISION OF EXISTING O C C «, DGP = DATA GATHERING PANEL TS = TAMPER SWITCH THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL CIRCUIT. co CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE Po = EMERGENCY POWER OFF 7YP = TYPICAL 1 00 a LION = UNLESS OTHERWISE NOTED 12ovac m SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER M CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT FATC = FIRE ALARM TERMINAL CABINET VT = VALVE TAMPER 3RD FLOOR o FBO = FURNISHED BY OTHERS WF = WATER FLOW w 2 DESIGN OF THIS SYSTEM INSTALLATION. FCC = FIRE COMMAND CENTER W = (eg. 1/2w) WATT 00 0 REFERENCE https:Z/www.anixter.comZcustomertycofs FOR SG ANIXTER CABLE DATA FAA = FIRE ALARM ANNUNCIATOR W WITH FTR = FIRE ALARM TRANSPONDER W%o = WITH OUT FSD = FIRE SMOKE DAMPER •� V zCq Tf w ti 8 DEVICE ADDRESSING LEGEND SEQUENCE OF OPERATION w � 0 o � J U) c 0o�? Q � C:) Q z M 0 CONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFELY CONTROL ADDRESSABLE CARD (IDNET OR MAPNET) DEVICE ADDRESS "- M2- 1 ��`' °``;� �\°` U�'�'' �° \�o���`G °`'�'' � �, �`J��t• q��° ADDRESSABLE DEVICES NUMBERING Z GPG GPC, �GPG GP4 �GP co) I� O CIRCUIT DESIGNATOR A B C D E� FF G HP� J K � P� R� � �U�V� Y Z A AD AF AG Q � REMARKS a 4009 NAC PANEL SYSTEM INPUTS Q s T w x AA AB c AE AH At AJ _ O 1 SMOKE SENSOR DETECTOR • 0 • • • • • • • 1 DEVICE DESIGNATOR LL (- 2 MANUAL PULL STATION • • • • • • • . • 2 -� N14-1 3 DUCT SENSOR DETECTOR • r • • • • 3 y. 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • + • • • • 4 51 ELEVATOR LOBBY SMOKE DETECTORS IXC. MAIN FLR. + • 1 • 1 • + • • 1 • • r r • 5 > VISUAL AUDIBLE OR DEVICE 6 ELEVATOR MECH. ROOM HEAT DETECTOR • • • • • • • • • 6 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • . 7 8 ELEVATOR SHAFT HEAT DETECTOR • • • • • • • • • • • • 181 0 co 9 ELEVATOR SHAFT SMOKE DETECTOR • • • • • • • • • 19 a 10 ELEVATOR POWER MONITOR + • • • + + • 10 11 ARE ALARM AC POWER FAILURE • + I I 1 • • • • • 11 12 FIRE ALARM SYSTEM LOW BATTERY • • 1 1 • + • 12 13 OPEN CIRCUIT OR GROUND FAULT + • 1 13 = 14 CLASS B NOTIFICATION CIRCUIT NAC - SHORT • • • • 14 v 151 15 16 16 217 1 1 17 CL 1 181w 0 19 1 1 19 c° 201 1 201 6 coco 21 21 'n 22 221 cl: 23 2 S g co 24 4 251 1 5 cri6 w 2 2 91 z 27 2 28 1 28 DRAWN BY: J.JOHNSON 9 Q 29 291 CHECKED BY J.JOHNSON 3 ISSUE DATE: 9118115 G 311 1 1 31 JOB#: 321 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ 3 PROJECT#: 448:987874101 SIMPLEXGRINNELL O 2015 if SYSTEM: s FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION a � x M GENERA._NOTES: o� 1. ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED �� CPT z OTHERWISE. w u 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. M E z Q=LL- GENER& NOTES: O w AREA OF WORK V ~ € c OEXISTING NAC CIRCUIT N28 IS TO BE CUT IN HALF do TERMINATED AS SHOWN. 1 OK END OF f-1 n Li Ll Li Li LINE RESISTOR IS REQUIRED FOR SUPERVISION OF EXISTING CIRCUIT. �� co'- x g Q)�* Opco a E- � car» OFFICE N28-11 cj W 303 C U w h V �: �0- N LO oxo i 5cWi� � !� w i OFFICE N28-12 V 15 304 15 �� O V N28-10 75 15 11a C m N29-2 N29-3 N29-6 - ®C V C . T C N28-9 15 E r7 1 /� V C V B 15 LD V N29-5 N30-7 15 '� � j cc OFFICE N30-8 C V 15 a 305 (RL) C EOLR DN. v C 3 N29-4 BREAK jj U v G 302 uP 1 10 1 1 1 7Bm 15 SCEP 301 M2-58 F N30-115 TO NAC M2-56� 1/N28--8 M2-54 15 75 OFFICE C M2-57 (� C V V PANEL ��/ C N29-1 306 C N29-7C N3a-5 WORK COPYFYI F M2-55 v W (RL) 15 310 (RL) V _ - V 30 E 15 N. V 00 C 15 V 15 15 OFFICE N30-2 C N29-8 C E C 0 309 O v N30-4 U P x V C 75 2-50 'NZ8- CONFERENCE M M4C! 307 N28-7 C AV v 15 V V N28-5 15 y (RL) 15 V® N28-1 15 V N29-9 C (� a l� k3C() U E C V C C Cl N30-6 (RL) 75 M2-52 ED O s N30-3 C 15 V � O 2 _ 15 ow C1 DC \J C N29-10 15 OPEN OFFICE N28-6 O EOLR 15 308 M2-5313 N28- o M2-59 RI i !B 3 r 1c s. 1= 0 m PIAN NORTH KEYP LAN 0,n0 SCALE: NTS PLAN NORTH 0 DEVICE PLACEMENT PLAN - 3RD FLR All A SCALE: 1/8* = 1'-0• ii 0 4 8 16 i o (IN FO T co o 00 00 M = "3°- -- °' N29 V N28- NAC-8 BATTERY CALCULATIONS - 3RD FLR NORTH ELEC RM NAC-8 NOTIFICATION APPLIANCE CIRCUIT SCHEDULE cu Standby Total Alarm Total PLAN CKT PANEL CIRCUIT DESCRIPTION O CURRENT A} m Module Description CRY Current Standby Current Alarm N28 NAC 1 3RD FLOOR EAST NOTIFICATION - EAST 11 1.252 T� U z N qac Panel Equipment N29 NAC 2 3RD FLOOR EAST NOTIFICATION - SOUTH 10 1.155 ' " W � ® N30 NAC 3 3RD FLOOR EAST NOTIFICATION - NORTH 8 0.836 ` W ® 4009-9201 4009 IDNET NAC EXTENDER, 120 VAC 1 0.085 0.085 0.185 0.1$5 N31 NAC 4 SPARE 0 0.000 J Total Panel Sthy 0.085 Tota! Panel Alarm 0.185 W 0 : s 4 Notification Appliance Circuits From NAC Schedule 3.115 t,,./ '--�-� ?� 0 g � IDNETE �^ z Total Periph Stby 0.000 Total Periph Alarm 3.115 V) J C!) 0 § ❑ .. ❑ ® ata an Y Amps 0.085 Iota[ arm Ps 3.300 0 O cc 0 Z GM, C7 0 VOLTAGE DROP CALCULATIONS - N28aiRn - -- WIRE GAUGE 14 AWG Q Doo , 2X WIRE RESISTANCE PER FOOT 0.00614 OHMSAUX POWER ° StandbyAlarm STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDGE lo�L a oQty Current Current MINIMUM DEVICE VOLTAGE 16 VDC Lu �*■ .wr 1 Control Panel Power (Master Power Supply) 0.085 0.185 PERCENTAGE VOLTAGE DROP 7% � ,�"a� „w o ° o Power For External Peripheral Devices O,OOp 3.115 ' DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT rQ"ar - ° 0.085 <-- Totals --> 3.300 NUMBER NUMBER A U A ROP DEVICE V) :g 4009-9201 ZDNet NAC EXTENDER °o ® n Standby Time = 24 Hrs 1.951 Standby Ah N28-1 4906-9104 15 28 0.075 1.252 0.22 20.18 m MW INS.-M` Ma j Alarm Time = 5 Mins. 0.263 Alarm Ah N28-2 4906-9104 15 24 0.075 1.177 0.17 20.01 Battery Supplied 2081-9272 6.2AH 3.460 Total Ah N28-3 4906-9104 15 21 0.075 1.102 0.14 19.87 N28-4 4906-9104 15 1 24 0.075 1.027 0.15 19.72 1VANIM' 0� N28-5 4906-9130 15 1 29 0.086 0.952 0.17 19.55 m Z oORM N28-6 4906-9104 15 26 0.075 0.866 0.14 19.41 p CONNECT TO 120VAC 60HZ INPUT 3A MAX. N28-7 4906-9130 75 34 0.250 0.791 0.17 19.24 Y Z+ - + - qui N2$-$ 4906-9130 15 29 0.086 0.541 0.10 19.15 Z: o SW N28-9 4906-9103 15 30 0.060 0.455 0.08 19.06 a P N28-10 4906-9130 110 30 0.320 0.395 0.07 18.99 � 6.2 Ah BATTERY 6.2 Ah BATTERY N2$-11 4906-9104 15 14 0.075 0.075 0.01 18.99 -W, 2081-9272 2081-9272 s m VOLTAGE DROP CALCULATIONS - N29 0 S CONNECT A 12 AWG CO NO MARE FROM SAFETY WIRE GAUGE 14 AWG a GROUND IN THE ELECTRICAL BU11ON PANEL TO 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS THE 4009 SAFETY GROUND STUD. STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDC C/3 uj MINIMUM DEVICE VOLTAGE 16 VDC PERCENTAGE VOLTAGE DROP 570 �c DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT NUMBER NUMBER FT CRR A C A ROP V o N29-1 4906-9104 15 29 0.075 1.155 0.21 20.19 N29-2 4906-9130 75 38 0.250 1.080 0.25 19.94 rn N29-3 4906-9104 15 27 0.075 0.830 0.14 19.80 w g coo' N29-4 4906-9104 15 21 0.075 0.755 0.10 19.71 o W q4 N29-5 4906-9104 15 23 0.075 0.680 0.10 19.61 0 N LO N29-6 4906-9130 15 28 0.086 0.605 0.10 19.51 __j CD N29-7 4906-9104 75 41 0.233 0.519 0.13 19.38 co $ N N29-8 4906-9104 30 25 0.125 0.286 0.04 19.33 g N29-9 4906-9130 15 21 0.086 0.161 0.02 1 19.31 1b (D N29-10 4906-9104 15 38 1 0.075 1 0.075 1 0.02 1 19.29 a Lu z DRAWN BY: J.JOHNSON cr o0.. CHECKED BY J.JOHNSON ISSUE DATE: 9/18/15 L JOB#: VOLTAGE DROP CALCULATIONS N30 PROJECT#: 448:987874101 WIRE GAUGE 14 AWG 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS SIMPLEXGRINNELL 2Q15 c STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDC SYSTEM: � MINIMUM DEVICE VOLTAGE 16 VDC FIRE ALARM SYSTEM s PERCENTAGE VOLTAGE DROP 4% 2-8 DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT SHEET: g NUMBER NUMBER FT CURR A CU ROP N30-1 4906-9104 15 80 0.075 0.836 0.41 19.99 DEVICE PLACEMENT PLAN, i-9- N30-2 4906-9104 15 25 0.075 0.761 0.12 19.87 N30-3 4906-9130 75 35 0.250 0.686 0.15 19.73 CALCULATIONS 8� PANEL N30-4 4906-9104 15 20 0.075 0.436 0.05 19.67 DETAIL N N30-5 4906-9104 15 20 0.075 0.361 0.04 19.63 m u, N30-6 4906-9104 30 22 0.125 0.286 0.04 19.59 W _9 Lu N30-7 4906-9130 15 35 0.086 0.161 0.03 19.55 5 -8 N30-8 4906-9104 15 15 0.075 0.075 0.01 19.55 L FA-101 ? c x C> a `"' 01 DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) END—OF—LINE RESISTOR CODES m C A/C SUPPLY VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS INrr 1"' 1. MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO DIFR SERV THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS NOTE: INS RUCTIIONEFER TO SNFORMPROPERODULE �TERMINATIONSD DEVICE STALLATION Col.- 1 E TOP OF LENS FOR 11 OCD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 �U-) 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" * USE WITH RETROFIT OR HIGH CURRENT MODULE w (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3 (MIN) 4" NOTE: MEASUREMENTS Z ' (1O2mm) SHOWN ARE TO THE REFERENCE � INTENSITY IS TO COMPENSATE FORA POSSIBLE SMOKE LAYER. MODEL OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL MODULE ""� 914mm MIN CLOSEST EDGE OF THE NUMBER PANEL/ MODULE) CEILING p w u` DETECTOR. 4081-9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) N g N.O. INITIATING 4004*, 4004R, 4005*, 4006, �� ~ w-C2, m CEILING MOUNTED PULL SMOKE HEAT 4100 4120 41000 ZAM S a1'" FOR CEILING HEIGHTS LESS THAN 86" (2180mm), NFPA 72 AUDIBLE APPLIANCE 4" ows SMOKE/HEAT 4081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW TAMPER ETC. 0 3a"' co w 0'�4 THEVISUAL LENS MOUNTING HEIGHT SHALL BE 6" MIN (152.4mm MIN) DETECTOR (102mm) 12" MAX) o 24 PT. 1/0 SWITCH SUPV. 4605-7401, 4100 SERIES � � g� WITHIN 6" (150mm) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING (305mm MAX) CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM EOLR ffj ��in di HEAT DETECTORS 4081-9003 733-896 43K YELLOW VIOLET RED GOLD N/A 1/2 0 90" MIN (2286mm MIN) ACCEPTED HERE / / NOTIFICATION DACT 2080-9024 U Ujc ABOVE FINISHED FLOOR NEVER HERE k {? aYd' J� FEE (OTHER MOUNTING HEIGHTS SHALL BE N.O. INITIATING 4004, 4005, s C-05 C PERMITTED BY THE AHJ PROVIDING IT 4081-9004 733-886 6.$K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, NEAT, 4090-9001 IDNET IAM AUDIBLE/VISUAL MEETS THE SOUND LEVEL OUTPUT REQUIRED. WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PTI 0 & VISUAL ONLY ) WALL MOUNTED 4-20MA ZAM TROUBLE APPLIANCES TO EXIT DOOR SMOKE/HEAT 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM (IN LINE) 5 (MAX.) DETECTOR y (1524mm} 4081-9006 733-890 560 n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM SYNCHRONIZE MORE THAN DOOR 4100, 41000 TWO APPLIANCES IN ANY WIDTH FIELD OF VIEW. LESS 3 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 (76mm) 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008, 4009, 4010, 4100, 41000 96" MAX (NFPA, ADA) 5„ SIDE WALL 4081-9009 733-912 200 RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 (2440mm MAX) (127mm) N.C. INITIATING ACROSS CONTACTS 4005*, 4090-9001 IDNET IAM $ r REF. 80" MIN (IBC) ABOVE FINISHED FLOOR MANUAL 4081-9010 733-973 1 K BROWN BLACK RED GOLD N/A 1 24 PT. i/0 (ACROSS CONTACTS 4605-7401, 4100 SERIES o (2032mm MIN} TO TOP OF LENS PULL CURRENT LIMITED N.O. INITIATING (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM REF. 96» MAX (IBC) STATION 80» —9011 733-974 100 CI BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 (2440mm MAX) MIN (ADA) (2032mm MIN) FIRE. 4081— 0 80" MIN (NFPA) (2032mm MIN) PHONE MAGNETIC 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 4 ABOVE FINISHED FLOOR TO BOTTOM OF LENS JACK ,.� DOOR 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1 2 Loo r"sm HOLDERZX N.C. INITIATING FINISHED 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM ® WALL NOTE: REFER TO THE PROPER DEVICE 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM INSTALLATION INSTRUCTIONS 48" MAX (ADA) (1219mm) (SECURITY MONITORING EOLR) N FOR BACKBOX MOUNTING HEIGHT. 48 MAX (NFPA 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 ADA) {1219mm MAX) .� FINISHED ) (1067mm MIN) 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 FLOOR 42 MIN (NFPA) 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 MEASUREMENTS SHOWN ARE 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING EOLR 4100, 41OOU W TO TOP OF PULL HANDLE 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 41000 � R 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 41 OOLI o rs TrueAlerf' NON—ADDRESSABLE MULTI—CANDELA VISIBLE NOTIFICATION APPLIANCE TrueAlerf'NON—ADDRESSABLE MULTI—CANDELA AUDIBLE/VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION PRODUCT INFORMATION FEATURES: (CEILING MOUNT) FEATURES: (CEILING MOUNT) *UL LISTED TO STANDARD 1971 (ERICCLNPOB AfVD) + CLASS B (STYLE Y) OPERATION REQUIRES CONNECTION •ADA COMPATIBLE WITHSUPPLIED BY CONTRACTOR TO A COMPATIBLE SMARTSYNC NAC OR TO SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: SMARTSYNC CONTROL MODULE (SCM) 4905-9938 s •SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE FOR CLASS B OR CLASS A OPERATION HANDY BOX, 1-1/2' DEEP OR 4905-9938 SCM OR 4100 SERIES FIRE ALARM 4' SQUARE BOX, 1-1/2' DEEP SINGLE GANG BOX, 2-1/2' DEEP CONTROL PANEL NAC'S •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE SUPPLIED BY OTHERS CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS OPTIONAL 4905QUIRE ADAPTER PLATE �} SINGLE GANG BOX SPECIFICATIONS: MOUQNTUED�ELEFCTRICALFBBOOX $ v WIREMOLD V5744s _ SPECIFICATIONS: � ( ) « HOUSING DIMENSIONS (INCLUDING LENS) : 4-3/4'L X 6 7/8' W X 2-5j8'0 _L__1 - \- 2-1/4' (57mm) • TEMPERATURE RANGE: 37 F TO 127 F (0' TO 50' C) CO— C/ •HOUSING DIMENSIONS: 4-3/4" L X 2-5/16' W X 2-5/8' D {i 21 mm X 75mm X 67mm} SUPPLIED BY OTHERS • HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100' F (38' C) P t= o •TEMPERATURE RANGE: 37F TO 127F (0 TO 5TC) • TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER OPTIONAL 4905-9915/-9916 ADAPTER •HUMIDITY RANGE 10X TO 93X NON-CONDENSING AT 100'F (38'C) 4905-9910 ADAPTER PLATE, TERMINAL FOR IN/OUT WIRING. p ( � 6 •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER F I `-� REQWITUIRED IREDHANFOR SURFACE MOUNT TERMINAL FOR IN/OUT WIRING. R THE 4905-9926 WIRE GUARD WIRING TERMINALS ARE STROBE LOCATED BEHIND HOUSING OPTIONAL 4905-9927 WIRING NOTES: - RATED VOLTAGE RANGE: UL: 16 VDC TO 33 VDC PER UL 1971 RED FIRE GUARD a, 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. ULC: 2OVDC TO 30VDC PER ULC S526-M878 o 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP - FLASH RATE: 1H STROBE INTENSITY VIEWING .2 T WIRES UNDER TERMINALS. ._ ---------be-------------- - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. - C . Strontensdy n 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER-LIMITED. '' vievkv slot ' U_ 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. Intensity selection plug, INTENSITY SELECTION PLUG, i --- accessible only from rear of lens *CURRENT DRAWS REFLECT STROBE FLASHING AND HORN ON. ACCESSIBLE ONLY FROM REAR OF LENS housing;factory setting is 15 cd HOUSING LETTERING STROBE RMS CURRENT ® HOUSING, FACTORY SETTING IS 15cd g o STROBE' E MODEL. NUMBER COLOR COLOR RATING � .C- • L----- ---J r"�. • 4906-9128 RED 86 rnA 76 ffiX-_57-FR_ RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 co OPTIONAL 4905-9926 WIRE GUARD ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 CEILING MOUNT WITH MOUNTING PLATEO a' •FLASH RATE: 1 Hz4906-9130 WHITE RED I 15cd 1 86 MA_ 76 mA 57 mA 00 v c' «SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. TO ADDITIONAL NOTIFICATION M FROM FRCP 24VDC NON-CODED _ ? NOTIFICATION APPLIANCE CIRCUIT — —3 APPLIANCE PDEVICE OR Z RETURN PPU4TION 222 mA 167 co (� cin *CURRENT DRAWS REFLECT STROBE FLASHING OR PRECEDING DEVICE, OR Z— —i IF LAST DEVICE ON CIRCUIT INA mA 213 mA c, SIMPLEX 4905-9914, 9922, OR + W HOUSING I..EITERING S CURRENT ® STYLE Y APPLICATION PLACE AN MODEL NUMBER QwLOR RATING 16 VDC 18 VDC 1 24 VDC 9938 SYNC MODULE. END-OF LINE RESISTOR. (RESISTOR Y - VALUE IS FACP DEPENDENT.) HORN :°_ - SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 Hz SWEEP, m C'4 �- MODULATED AT 120 Hz RATE "��' W c 67 mA 111 mA 83 mA W N 20 mA mA z W � r- 281 mA 211 mA HORN SOUND OUTPUT RATINGS 0 10 FT. (3m) + - acr+cxr- c -� SOUND TYPE * STEADY CODED STEADY CODED STEADY CODED 0 VOLTAGE 16 VDC 24 VDC 33 VDC O T- REVERBERATE TEST BER 86 dBA 82 dBA 88 dBA 8.4 dBA 90 dBA 86 dBA � o � o V � O U) C ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA END-OF-UNE co FROM FRCP 24VDC NOTIFICATION + + •� * RESISTOR (VALUE � � z M CODED VALUES ARE TYPICAL OF THE OUTPUT MEASURED WITH A TEMPORAL APPLIANCE CIRCUIT OR SIMPLEX _ CD CL CODED OR A MARCH TIME CODED PULSE AND WITH A SOUND LEVEL METER 4905-9914, 9922 OR 9938 - IS DEPENDENT J _„r T� READING ON A 'FAST' SETTING. UNDER THE SAME TEST CONDITIONS, CODED SYNC MODULE OR PRECEDING DEVICE ON FRCP) � HORN OUTPUT "PEAK' SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. S d _ w Li 3 92 c z 0 z - - 0 Wre a CIO z O a � U U W a Y U m a Q U 0- th w coa ato q N 010 2 03 U.1 z DRAWN BY: J.JOHNSON a CHECKED BY J.JOHNSON gISSUE DATE: 9/18/15 JOB#: PROJECT#: 448:987874101 SIMPLEXGRINNELL© 2015 SYSTEM: FIRE ALARM SYSTEM Z SHEET: WIRING TYPICALS I a co w [Y r �� V OR 1 uj ge Q � W FA-701 x Z� M i