Plans (7) i FPS2015 00102 FLOW TEST DATA HYDRAULIC DEMAND Static Pressure 60 psi Density .05 gpm/sgft Flow 1230 gpm Area 2 heads Residual Pressure 48 psi Required now 26.1 gpm Test Date 15 Dec 2014 Required Pressure BOR 30.7 psi Hose Flow Included gpm JUN 2 9 20+15 My OFTRIARD BUILDING DIVISION A A COVERED '...,,. ". K ..�......... 20/Ox5/O .__.,._......_.___........... _...._.. ........_...._...._._.....-......... ...._..._..........._.__.,._..,__....- 1 I I COVERED `�. g' DN 20/0x10/0 ..... :,H»,:,»: ,.::.:..:..:F ... ...... 3 0x5570 ...... o, , 1 GARDE TUB O t I SHOWER � "`•... € 9' CLNG. f HERS 14/0x11 /0 I 1-2'' '-"'� i lo'-0, I � I 8 LNG. 7 M ..f.". . U P ups'. �J € 1 � .. 8 DN I µ r 14/E 415/8 9' CLNG. 20/0x16/ 4161 Z D.W. I 9 I DN 10 0 ...... 3-O�s 6-11�: 8-51s 'M�, —' ao ao 014 • I I ` 2�4 � f .,. .., . C , h: w H I S 8' CLNG. 5 , ... . ,,,� . I :. +-s 6 ( 12/8x12/10 2'-6' J I RAIL � f"" REF�R... ..................... N ' PANT ' ' __ �A � I FLUE J. :--::- ::::: µ :: :::::::::::::::::::::::::::::::: : : :. °I 71/ ,,, . . a 0 J rB 4Lj .... .............. ,'—,D• �. . fff,,,...j....; i N r • y. ................: I � TUTP& N 12 DN ' N r-3' 2'-7• fi'-21/2• x s �o 19/2x20/8 FOY. :X-J' ,- 8' CLNG. ' 8 CLNG. I r o `„ ; . �' # B �-;: CITYOFT h1 ` :f.... . . � . ._ 4/6x 3/0 1 1 IGA.RD 13/8 x 12/0 REVIEWED I OR CODE COMPLTANCL Approved: [ �� OTC: .. ................; 9' CLNG. I tmm I �3:�'`.€ 1 .� "),� �t < <..� I ..: r-- ..^ ...... ............ Address: Permit '2p Di.....: 1 1 P P 9/0x11 /4 I suite#: By: Date: I� I I I-- .. _ 3 5 A ................... A OFFICE COPY MAIN FLOOR PLAN UPPER FLOOR PLAN 1 ,060 SQ. FT. 1 ,400 SQ. FT. NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-1 All piping and fittings to be CPVC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 6 All hangers to be CPVC Standoff type and located per NFPA 13D requirements. O Concealed Pendant, 4.9 K-factor, 160', Quick Response, Qty. 23 "" MAIN♦UPPER FLOOR PLAN Max.sprinkler spacing to be 16'x 16'w/8'-0"off walls. ♦ PERMIT NO. All CPVC piping to be 1"w/Riser to be 1" black steel piping. -€< :. 15152 SW HARVEY'S VIEW AVENUE CONTRACT NO. C15-462 Me design requirements of NFPA 13D 2013 edition. WYAT Meets des 4 9 ,. All piping to be installed before insulation and protected with a medium weight plastic barrier to be provided b others). APPROVAL PP 9 P 9 P ( P y ) FIRE PROTECTION,O N INC OREGON 9 •� :: TIGAR REG N 7223 Riser to be connected to domestic water prior to hot water heater. ° DRAWN BY A PAYNE Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 9095 S.W. Burnham plumber) Tigard, 0R 97223 SCALE 1/4"= 1'-0" DATE 25 JUNE 2015 (503) 684-2928 STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 REVISED PLOTTED FP 1 of 2 LOT 61 W 73 34'-4 1/2' QL 993 ELu323' 32 • I I 335.5 21'6 Conrete 420 DrI eway '" Ila 0 I" I M E33D 2, i ah 32 I 2 3, *2038I ! i 'n • 2~ $QFT. o r'd DORM. a z S W ,� I Z 1/1 N z 421 m U STORM_ I 3"9 3 L___�- -------- --14 TO SYSTEM 1" CPVC .•••• n Lh331"\ 99.3 EL•315' IT-11 3/4' 2S'-4 1/4* 91C PRESSURE GUAGE LOT 5 POTTER VSR-S 1"DCVA AMES WATERFLOW SERIES 20006 ALARM SWITCH � SITE PLAN ,C : 0 1"CPVC TO PUBLIC SUPPLY R-49 BLOWN—IN INS W_..... � 4x10_HDR. FLOOR s BATH HALLWAY LAUNDRY M. BATH B - RISER DETAIL 0 2 12"OF BATT OR 4 BLOWN-IN INSULATION :.; R-30 INSUL. BLOCKING MEDIUM WEIGHT PLASTIC ...... .. ..::....:::.. BRANCHLINE W/PIPE STRAP BARRIER OVER LINE PIPING GRADED BACK TO MAIN GARAGE GREAT RM . 1"x DROP (SEE PLAN) 2X FRAMING :...... m� :.. GYP.BOARD R-38 INSUL. w I CRAWL I SPACE OW it F Z_ O A - CROSS SECTION C - TYPICAL INSULATION COVER NOTES APPROVALS AND INSPECTIONS SPRINKLER SYMBOLS FP-2 All piping and fittings to be CPVC. DATE DESCRIPTION SOUTHVIEW HEIGHTS LOT 6 All hangers to be CPVC Standoff type and located per NFPA 13D requirements. 09M SECTION + DETAIL S Max.sprinkler spacing to be 16'x 16'w/8'-0"off walls. PERMIT NO. All CPVC piping to be 1"w/Riser to be 1"black steel piping. ° CONTRACT NO. C15-462 15152 SW HARVEY'S VIEW AVENUE f NFPA 13D 2013 edition. Meets desi n requirements oWYAT "'I' 9 q All piping to be installed before insulation and Protected with a medium weight plastic barrier(to be provided by others).. APPROVAL FIRE PROTECTION, I N C TIGARD OREGON 97223 Riser to be connected to domesticwater prior to hot water heater. DRAWN BY A PAYNE Double check to be provided by Wyatt Fire but installed, permitted and tested by plumber(contact Stonebridge Homes for information on 9095 S.W. Burnham plumber) Tigard, OR 97223 SCALE 1/NE 20 5 DATE 25 JUNE 2015 (503) 684-2928STONEBRIDGE HOMES, 4230 GALEWOOD ST, #100, LAKE OSWEGO, OR 97035 REVISED PLOTTED FP 2 of 2