Plans (17) FPS2O1 4- 00187
,:rZ O
N N
B 1 I it ji?kEL DB Eti NC Cr,DE, .
RICEIvjp
af 0 a) n
0) 0) r
ca O i
y >, a) J co II E
c c o
0 Lo to in 2
o
0 0) -�
Z (1) , �,
v c c m
> (so oc . .
2 °' ori
o: o n. n" ,- v as
< O c4 cn 0 co 0
GENERAL NOTES
FIELD FIT 3"x 2"
1. WSFP CONTRACT SCOPE SHALL START AT EXISTING 3"TEE CONNECTION BY EXITING PAINT BOOTH RISER. FOR BRANCHBRIcLINES SEE ISOMETRIC VIEW
SHALLBE PROVIDEDBY OTHERS. --_ _�, -- 11,71
2. ALL ELECTRICAL WIRING ANDINSTALLATION Wiz >z s o :viii. „{ MAr�.7eYle.•�s�� _:....... .............. ^s_� i*�:�si; r a3 r� :i
;__ .
3. FIRE ALARM SYSTEM AND PANELS SHALL BE PROVIDED AND INSTALLED BY OTHERS. SWAY BRACINGsl, ,�,;��� 2W FEED TO EXISTING PAINT BOOTH ��
4. ALL PIPING SHALL BE HYDROSTATICALLY TESTED @ 200 PSI FOR (2) HOURS. 2 �'�,. / •
0,8 Y Z��zR�; .
�'of 11 I 2"DRAIN ELBOWconc red 2"DRAIN ELBOW
5. EARTHQUAKE BRACING SHALL BE PER NFPA 13 2010 ED ON NEW PIPING. '` 1 IIIA 9 4�9„ \ AT PIT FLOOR \
3 AT FLOOR \
�y 9 12'_0 '' 1,-10 :, _-' 2'FEED DOWN TO 8'-7h/z I 4'-s
6. ALL APPROVED COUPLINGS ARE RIGID UNLESS OTHERWISE NOTED. ND\ ; 9'-4% A app, �ry SPRINKLERS IN PIT EXISTING PAINT BOOTH FOOTPRINT EXISTING PAINT BOOTH FOOTPRINT
N r ' SEE SECTION VIEW •
j V 7. ALL NEW FIRE SPRINKLER PIPING ISTO BE SCHEDULE 10OR 40 BLACK/GALVANIZED STEEL.
8. SPRINKLER SPACING AND HYDRAULIC REQUIREMENTS PER MANUFACTURER'S SPECS. 6 e POST-FILTER SPRINKLER
O ED FROM OVERHEAD PIPING 1 ‘•'2.-i '-'6` Off"
9. ALL MATERIALS SHALL BE NEW, UL LISTED AND/OR FM APPROVED N •
1 FIELD FIT PIPING •
3'-11 +� j
EI
SPECIFICALLY FOR FIRE PROTECTION USE. N` . o No`° j
fo
10. PAINTING OF PIPE AND PROTECTION FROM PAINT IS NOT IN CONTRACT(NIC). ��' ( N N '3
11. THE COMMODITY CLASSIFICATION OF THE AREA OF WORK IS EXTRA GROUP II. PRE-FILTER SPRINKLER PRE-FILTER SPRINKLER •
r FED FROM PIT SPRINKLER PIPING ►4 ►. v od
12. BACKFLOW DEVICE IS NOT INCLUDED IN WESTERN STATES FIRE PROTECTION'S CONTRACT. ;.; 1 �, sEEsecnoNVlEw
o a.0 4 3'-11.` ' X h N r
13. SEISMIC UPGRADE OF EXISTING PIPE IS NOT IS WSFP SCOPE OF WORK. % . �I \ ti O
14. REPLACEMENT OF EXISTING PIPE BEYOND IS NOT PAINT BOOTH AREA IS NOT IN CONTRACT.
F
c N, ` J) �� ��/���� :. g 'X-,-5;- \; .\\"\\;,..X.</,',//�l/l//// �� --rill::_:.::- o to E
15. LATERAL SWAY BRACING ON FEED MAIN IN PAINT BOOTH SHALL NOT BE INSTALLED BECAUSE PIPING N N "N MAX % `� E `� E
WILL NOT BE HELD BY ALL THREAD RODS. _ W _ �, _,••_ �� I • " 0 co 0
3_11 .,,r
16. BRANCH LINE RESTRAINT IS NOT SHOWN, BUT WILL BE INSTALLED BER NFPA 13, 2013 ED. o o I ® ��
LL LL
17. WATER FLOW DATA WAS NOT AVAILABLE FOR THIS LOCATION, SO THE PAINT BOOTH SHOWN EXHAusT DucT SPRINKLER t 0 0 0
Y �ED FROM OVERHEAD PIPING PIT AREA \ O O O
WAS DESIGNED WITH THE SAME OR LARGER PIPE SIZES AS THE ADJACENT PAINT BOOTH ON SITE. 1'-3 - 1'I I FIELD FIT PIPING T�' ��® SEE SECTION VIEW N N N
18. WSFP WILL BE USING THE SAME PIPING SCHEME AS THE ORIGINAL PAINT BOOTH ON SITE, BUT WITH -� N
ALL EQUAL OR LARGER PIPING, IN ORDER TO PROVIDE ADEQUATE WATER DISCHARGE. I�
�^ / o
/ \ 1 '::‘..\‘,„\-.—
\ N_ N
Z Co (JDI,-
/
CO
— I 2
Ceo
J
a�
Q a)
— - ® — IN--1 Q- O" D- N
O O p c
vv �Ny L
I1 LL Q
co
PLAN VIEW - ABOVE GRADE AREA OF PAINT BOOTH PLAN VIEW - BELOW' GRADE AREA OF PAINT BOOTH i
SCALE: 1I8"=1'-0 SCALE: Ile'=1'-0 •
O O O O O
:F+ -o "O "O
N N 0) O U) I
0 75 _ _
03 (6 as
0) D N i
O
EXISTING 3"OVERHEAD SYSTEM PIPING fn
./
r
''lifglf F s-2 I £ + est 'CS a
DRY SPRINKLER IN
EXHAUST DUCT STACK \,•:.-i-x----.,i
. '"r. a = »9
12
PER NFPA 33,SECTION 9.4.6
a �•.'_: (0
FEED MAIN AN •D {
BRANCHLINE PIPING ( • 1 , =
H
_ POST FILTER SPRINKLER t:r' , `'
FED FROM OVERHEAD PIPING co .�
.c''''' \ ‘j' FIELD FIT PIPINGP5-tjakitir:ii littilittlitigha O 0
Ws
PENDENT SPRINKER , N •Q
iii",.,...------------/
„.
IN PAINT BOOTH ` •5 -�
EXISTING PAINT BOOTH'S �-t re . 'Y' -,-,..4.---,.. In
'.4, rts,,;4,iiii:::Atiiii,iiz-- ,, :::,-ita,,..,:i.:ii,„..-#.50.4.11:&,--sor-,,i.r.:4 .,,:,,,,:21;,,,, _a
2W DIA FEED MAIN 1a £ ''
::':::
/
t
fi J �� I CO
0)
Milt PRE-FILTER SPRINKLER t Sex r g
L-_— FED FROM PIT SPRINKLER PIPING
F.
�.. '�. .,i'''--sir ..,,. AO' � :::::::::::::::::: ,F,,':::;;,7-;'''',4\; �k
f,11:iilff
'„ilg.itk;77?r11;*:'•-44.''''''''1;i ;;fif:'r'::A-i''''•4l.1-. !":1:04-4111''iiiii
UPRIGHT SPRINKLER IN
AIR EXHAUST PIT ��x
POINT OF CONNECTION
- r
SECTION VIEW OF PAINT BOOTH • Z
4,14,fiti,•;],`:‘,,,,,i,:•••••41::
FOR NEW SYSTEMS NEW PAINT BOOTH'S a r 3 .
3'DIA FEED MAIN$
SCALE: 1I8'=1'-0 �. 8 `
1, x Ana . rbc • ..-VpiqF x r �: Y A:- , k§� 6
' b�x da# Ta ,.mss "� '�' H( ; y �.
•
iii'
E
- CITY ONG.AtD
REVIEWED FOR CODB COMPLIANC.
F
PRESSURE GAUGE,AND DRAIN. VICINITY MAP Approved: ri1,4`,,
te'NOT TO SCALE 3"DIA FLOW SWITCH,
OTC:C:
Permit#: -f (4--- IR-7
. Address ) UI I
STEEL SAMMY SCREW %x4 Machine(Hex)Bolt {-r=1 —
Suite :
NEW 3"CONTROL VALVE FOR AND ROD B . ke' Date. C CQ l
FIRE SPRINKLER SYSTEM ��I,��
x 5 Machine(Hex)Balt
(Fig.1000)"Fast Clamp"Sway Brace (Fig.4L)"In Line"Sway Brace / /J
r\ MI'e LAG �s LAG Attachment Attachment / (2_11C- ('/j
+� (Fig.980)Universal Swivel (Fig.980)Universal Swivel Sway GGG
Sway Brace Attachment \ Brace Attachment
NEW PAINT BOOTH RISER DETAIL Z PURLIN OFFICE COPY
12 PURLIN DEPTH •
I� In. Rod
dTientto PdRod ipe \
a5' eio> � 1'Pipe,Schedule 40
NOT TO SCALE _
.r
SAMMY SCREW �I\\ 1'Pipe,Schedule 40 L
318" Alk
All - ll��/' PIPE RING
Thread E.-.
�\.//
Rod
I•I When Burch Lion vs supported by rods yr* Nn r Long Branch Linn Rsstrsu,r
a nq,ind.Insal Restrsnr as d.xdwa eboo.on rhe sd spmlder m s isr end.
PIPE rMrvNs as requtred'n NFPA 13.2007 Tad*93.0.4.
SWIVEL RIN A. j
' . n States Fire\/% BRANCH LINE RESTRAINT(BLR) FIRE SPRINKLER PIPING PLANit-
Scale:None LATERAL BRACE TO ONCRELONGITUBINAL BRACE TO CO COLUMN
I n � � ■ ■ SHEET
sArtistic Auto Body�LHANGER DETAILS BRANCH LINE RESTRAINT
NOT roSCALE N.I.S. N.TS-13896 FIR ST. SUITE B, OREGON CITY OREGON 97045 New Paint Booth Sprinkler System
WESTERN STATES FIRE PROTECTION COMPANY OFFICES LOCATED
FP-01
ALLAS/DECQ TU A DENVERAUFORT CCo?
LINSIHO/USSTONADKAO NSAS CITY 7585 SW H unziker St.
LAS VEGAS
ANTONIO/SEATTTLE/ /SPOKANE//ST. LOUIS TLAND/RAPID CITY/ N DIEGO Tigard, OR
Phone: (503) 657-5155 Fax: (503) 657-5182 97223