Plans (7) F'PS201 3 00144 SYM DESCRIPTION MODEL NUMBER BACKBOX CEILING F F RECEIVED 10 013 � OCT��T >, o zo,3 LEAR 6"MIN Project Name: VACANT SPACE Standby Hours: 24 CITYOFTIGARD ELECTRIC Project ID: suITE azo Alarm Mins:�� gUILDINGDNIS[ON NAC NAC EXPANSION PANEL SK-5495 EXISTING 6"MIN 6"MIN 30' MAXIMUM HEIGHT Prepared By: Oleg Primachenko Derating Factor: 1.2 COMPANY F - Date: 10/9/2013 Voltage Drop Warning INCORPORATED ,•-r • r• Threshold% : 10 6002 NE 112th Ave. Portland,OR 97220 F F Panel ID: 15495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps (503)255-0733 Location: 13rd Floor Volts: 24 VDC Max Panel Current: 6.0 Amps (503)255-0676 fax www.LearElectric.com Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ ° GE Ckt.# Circuit Name Standby Alarm & Type 1000 Ft. One-Way /o Drop F 4 CEILING HORN/STROBE UNIT 1-GANG STANDARD ELEC.BOX FACP OR FAA YP y Ohms EOL CCB#52278 5499 5495 Pwr Module 1 0.075 0.205 � 96°MAX 96" AX INmEEVP OONPldCTSAREDISCOVERED 5 C CEILING STROBE UNIT GE 1-GANG STANDARD ELEC.BOX EXTENDER NAC#1 5495Circuit 1 cfg. 0.000 0.960 -14 Solid - 2.52 320 1.61 18.85 7.59% HKIWEENTHE ORIGINAL SIGNED AND SEALED DOCUMENTS PREPARED BY THE PANEL F 60" NAC#2 5495 Circuit 2 cfg. 0.000 0.760 1-14 Solid - 2.52 140 0.71 19.86 2.63% ARCHMECTSAND/OR THEIR CONSULTANTS, WALL HORN/STROBE UNIT GE 1-GANG STANDARD ELEC.BOX 90'rMIN ANDANrcoPTOFTHEDOCUMEN'S F APPROX. 80" „ NAC#3 5495 Circuit 3 cfg. 0.000 0.000 >14 Solid (• 2.52 0.00 20.40 0.00% TRANSMrMDBYMArL RAX, 72” MIN 80 MIN F NAC#4 5495 Circuit 4 cfg. 0.000 0.000 >1a Solid i- 2.52 0.00 20.40 0.00°� ELECTRONICALLY OR OTHERWISE,T'HE WALL STROBE UNIT GE 1-GANG STANDARD ELEC.BOX BOTTOM BOTTOM ORIGINAL SIGNED erroSEAT DDO r ENTS 48"MAX OF LENS OF LENS Aux 5495 Aux Power Out cfg. 0.000 0.000 -14 Solid - 2.52 0.00 20.40 0.00% SHALL GOVERN. ❑J JUNCTION BOX ----- 2 GANG ELEC. BOX Total Standby Current (Amps) 0.075 1.925 Total Alarm Current (Amps) ©Copyright Lear Electric 2013 42,MIN This drawing mntains informatlon theta Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) property of lost Elcctic C°.,Inc.This drawing is ot Total StandbyAH Required 1.800 0.160 Total Alarm AH Required receiveddisclosed without Lear Fnsy ncv be disclosed wlthont prior convent of Lear Elects Total Combined AH Required 1.96 Co.,Inc.This drawing shall not be used for INDICATES NAC INITIATING DEVICES FSD FIRE/SMOKE DAMPER FINISHED FLOOR Wire resistances arebased upon an ambienttemperatureof 72degrees F. Because competitivebidpurpoess. CIRCUIT WIRIN Multiply By The Derating Factor 1.20 of the min imil difference between solid and stranded wire no differential was made. G SD SMOKE DAMPER(M)-## DEVICE/ADDRESS NUMBER T.P. TAMPERPROOF Minimum Battery AmpHours Required 2.35 INDICATES SLC MODULE(M)/ANALOG INPUT EOLR END OF LINE RESISTOR LOOP WIRING TYI' FIRE ALARM DEVICE MOUNTINGDTE�# SLC LOOP NUMBER EOL END OF LINE INDICATES NOTIFICATION Cd CANDELLA _ 10/9/2013 EXISTING WIRING N#-# WP WEATHERPROOF G SCALE: NONE CIRCUIT NUMBER W.G. WIREGUARD REVISIONS NAC PANEL NUMBER f •-��c� 379&S ee ;- 1 f 1 5 N (E, M -rbc �i 1 5c N ■ as 75cd 1 a E L , N _ ,NAC2-2 ^ � / Fes C N EOL /� rT ❑� NAC2C2-1 , �y OFFICE 09 RECEP 1Z7,AJ (E) r 700 SUITE 3!0 I 0 ■ NAC2 � MMC) (E) (E) FSI �-I BUR DING lh� € �, ELECT I35L 15cd( E) 75c1 /0) , nlr' #_ r , X11 (E) 75cd V �( EL EVA F0 LOBB rT 35: IN ■ NAC2-2 co 00 t (N)14/2 wire (E) 0 1 I F 75cd OFFICE ° (N) 115cd 105 OFFICE 1104 DFFi�F m DRAWINGS Iwll CITY OF TIGARD by Approved.... .._._.... . Conditionally Approved..............[ ] Op See Letter to:Fol low,,,.„„„„„,,,,[ ] Atta had.. ] 00 Permit Number. ?L�(�00f o_ 083 SHEET Address- By: Date: 16 32 0 N Approved plans F1 ,l shall be on 'pb sy' e. - �0�L� (( — - - - - - - - OFFICE COPY