Plans (9)
PS2013-00125 U U T T T T T T T T T 7 RECEIVED _slei 2 8 2013 CITY OFTIGARD BUILDING DIVISION G) O b b O O b b b O 1' Si 10' 20' WALWART OUTLOT RETAIL BUILDING #2 SCALE: 1/8" = 1' FIRE ALARM GENERAL INFORMATION A. ALL WIRING TO BE IN ACCORDANCE WITH NEC, LOCAL AUTHORITIES, AND APPLICABLE CODES. EQUIPMENT GROUNDING CONDUCTORS, IF NEEDED, ARE NOT SHOWN ON THE DRAWING, UNLESS OTHERWISE NOTED. B. DISCONNECT POWER BEFORE SERVICING SYSTEM. C. ALL DC ALARM SIGNALS ARE MARKED SHOWING POLARITY OF OPERATION, THE POLARITY REVERSING DC ALARM INDICATING CIRCUITS ARE MARKED SHOWING POLARITY OF SUPERVISION. CONNECT ONLY 24VDC POLARIZED ALARM SIGNAL. D. ALL SUPPLEMENTARY POWER MUST BE FUSED. USE ONLY UL LISTED POWER SUPPLY FOR FIRE PROTECTIVE SERVICE. E. INSTALLATION TO BE PER NFPA 72. F. SEE INSTALLATION INSTRUCTIONS SHEET PACKAGED WITH FIRE ALARM SYSTEM DEVICES FOR ADDITIONAL INFORMATION. G. SEE DATA MANUAL(S) FOR ADDITIONAL INFORMATION. H. MAKE SURE THAT ALL POWER-LIMITED/CLASS 2 WIRING IS SEPARATED AT LEAST 0.25 INCH FROM ANY WIRING THAT IS NOT POWER -LIMITED. I. LOOP WIRE IN ALL J BOXES FROM TOP OF CAN TO BOTTOM OF CAN BACK TO TOP. J. TO PREVENT CONFUSION AND POSSIBLE ERRORS, ALL CONDUCTORS SHOULD BE TAGGED OR OTHERWISE CODED AND LOGGED, AT INSTALLATION, TO IDENTIFY CIRCUIT ASSIGNMENT, POLARITY, AND WHETHER THE WIRING IS OUTGOING OR RETURN. K. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. ---- - A RM LEGEND SYMBOL DESCRIPTION MANUFACTURER PART NUMBER FACP FIRE ALARM CONTROL PANEL SILENT KNIGHT 5208 0 MANUAL PULL STATION SILENT KNIGHT PS -SA G SMOKE DETECTOR SYSTEM SENSOR 2W -B ® TAMPER SWITCH BY OTHERS UJ V) `J ® FLOW SWITCH BY OTHERS ti I>& HORN -STROBE, CEILING MOUNT (MULTICANDELA) SYSTEM SENSOR PC2R @ STROBE. CEILING MOUNT (MULTICANDELA) SYSTEM SENSOR SCR 0 WATER FLOW BELL SYSTEM SENSOR SSM24-6 / WBB WP WEATHERPROOF BACKBOX F.X.Y F = FACP NAC CIRCUIT, X = CIRCUIT#, Y = DEVICE# Z— X Z = ZONE, X = ZONE# EOLR END OF LINE RESISTOR IMPORTANT NOTES 1. DO NOT START INSTALLATION BEFORE SYSTEM IS APPROVED BY THE AHJ. 2. REFER TO SHEET FA -2 FOR WIRING DIAGRAMS, MOUNTING HEIGHTS, AND RISER DIAGRAM. 3 -REFERS O SH EE FA -2 -FOR VOLTAGE -©ROP AND BATTERY CALCULATIE NS-.. FIRE ALARM H W z 0 W SEQUENCE 1= ¢Z UJ V) `J OF N Z z ti 0 � o = z rn 0 OPERATIONS 0 z v(/j NOTES: Z W .S W m � CENTRAL STATION ALARM SERVICEZ o Q o 0 TO RECEIVE SEPARATE & DISTINCT F ~ 5 � r SIGNALS AS FOLLOWS: Q Q 0- 0 u 3 A. ALARM w t: f- F- Q cn B. SUPERVISORY z z z z a C. TROUBLE conACTIVATION o 0 OF MANUAL PULL STATION • i • ACTIVATION OF SMOKE DETECTOR • 0 • ACTIVA110N OF SPRINKLER FLOW SWITCH • • • • VALVE TAMPER SWITCH • • TROUBLE CONDITION AT FACP • i MY OF TIG,ARD Approved...: C ConditionallyApproved.-........... ( 1 See Le%rt0: Follow.....__.J L i Attached Permit Number:'"~"2L3t�GL Ad $y: Date: I `t Approved pigs: shall be on job site. OFFICE COPY , �)J5 ec 2121 N.W. THURMAN PORTLAND, OR 97210 503.224.3511 www.e-c-co.com 6 z O REVIEWED BY: ERIC PUSKAS NICET 94139, LEVEL III CET FIRE ALARM SYSTEMS SHEET: 1 OF 2 H W W UJ V) `J OO F— <ad� J Q N Z M p LY 4 D H E`" � o 0 0 6 z O REVIEWED BY: ERIC PUSKAS NICET 94139, LEVEL III CET FIRE ALARM SYSTEMS SHEET: 1 OF 2 RNG TIPNNG VP RING TIP i TIP PROG O T1 P P2 RS232 O vim vErqvuNvrnruqvEm vuq All >-wwwmgw No a 2_ m N h � U ow nz a�. $w z ma z N Av Y2 vim O ALARM O TROUBLE O SUPERVISORY O SILENCED z O AC i wo Z + rljTF3� g+ a u RESET r4_1 F5� F6-1 Pi D J :4-xz Lot - 1D ® M ? �� A+ � N 04 � V N Z G � V OIL M 99 Rm 0 n< N wt! a o m El * a❑ m =1a a O O FACP - SILENT KNIGHT 5208 SYMBOL GAUGE WIRE TYPE CONDUCTOR A # 16 AWG UTP-FPLP - 2 CONDUCTORS B # 14 AWG UTP-FPLP 2 CONDUCTORS C # 12 AWG UTP-FPLP 2 CONDUCTORS FROM PREVIOUS TO NEXT F.A. DEVICE F.A. DEVICE OR NAC OR/ EOLR SYSTEM SENSOR CEILING STROBE & HORN -STROBE IMPORTANT NOTES 1. VERIFY WIRING CONNECTIONS IN INSTALLATION MANUALS BEFORE ROUGH -IN. 2. VERIFY MOUNTING HEIGHTS WITH AHJ BEFORE ROUGH -IN. PROVIDE TWO (2) 12V-7.5AH BATTERIES FACP VOLTAGE DROP CALCULATIONS BATTERY CALCULATION FOR FACP VOLTAGE APPLIED VOLTS QTY MODULE DESCRIPTION SUPERV. ALARM TOTAL SUPERV. TOTAL ALARM 0.031 WIRE SIZE AWG CURRENT, A CURRENT, A CURRENT, A CURRENT, A 1 SK -5208 FIRE ALARM CONTROL PANEL 0.140 0.460 0.140 0.460 1 2W -B SYSTEM SENSOR SMOKE DETECTOR 0.000 0.130 0.000 0.130 FACP SUPERVISORY AND ALARM CURRENTS WIRE SIZE AWG 0.140 0.590 8.26% NOTIFICATION APPLIANCES 18.71 CIRCUIT #3 VOLTAGE APPLIED VOLTS 20.4 WIRE RUN LENGTH FEET 202 WIRE RUN CURRENT AMPS CIRCUIT fi WIRE SIZE AWG 14 VOLTAGE DROP X 0 SCR -15 SYSTEM SENSOR 15CD CEILING STROBE 0.000 0.066 0.000 0.000 0 SCR -30 SYSTEM SENSOR 30CD CEILING STROBE 0.000 0.094 0.000 0.000 0 SCR -95 SYSTEM SENSOR 95CD CEILING STROBE 0.000 0.181 O.ODO 0.000 0 PC2R-15 SYSTEM SENSOR 15CD CEILING HORN -STROBE 0.000 0.079 0.000 0.000 0 PC2R-75 SYSTEM SENSOR 75CD CEILING HORN -STROBE 0.000 0.176 0.000 0.000 0 PC2R-95 SYSTEM SENSOR 95CD CEILING HORN -STROBE 0.000 0.194 0.000 0.000 1 SSM24-6 SYSTEM SENSOR BELL 0.000 0.031 0.000 0.031 TOTAL CURRENT CIRCUIT 11 0.031 CIRCUIT #2 0 SCR -15 SYSTEM SENSOR 15CD CEILING STROBE 0.000 0.066 0.000 0.000 0 SCR -30 SYSTEM SENSOR 30CD CEILING STROBE 0.000 0.094 0.000 0.000 3 SCR -95 SYSTEM SENSOR 95CD CEILING STROBE 0.000 0.181 0.000 0.543 0 PC2R-15 SYSTEM SENSOR 15CD CEILING HORN -STROBE 0.000 0.079 0.000 0.000 0 PC2R-75 SYSTEM SENSOR 75CD CEILING HORN -STROBE 0.0001 0.1761 0.000 0.000 3 PC2R-95 I SYSTEM SENSOR 95CD CEILING HORN -STROBE 1 0.0001 0.1941 0.0001 0.582 TOTAL CURRENT CIRCUIT 12 1.125 CIRCUIT #3 0 SCR -15 SYSTEM SENSOR 15CD CEILING STROBE 0.000 0.066 0.000 0.000 0 SCR -30 SYSTEM SENSOR 30CD CEILING STROBE 0.000 0.094 0.000 0.000 2 SCR -95 SYSTEM SENSOR 95CD CEILING STROBE 0.000 0.181 0.400 0.362 0 PC211-15 SYSTEM SENSOR 15CD CEILING HORN -STROBE 0.000 0.079 0.000 0.000 0 PC2R-75 SYSTEM SENSOR 75CD CEILING HORN -STROBE 0.000 0.176 0.000 0.000 2 PC2R-95 SYSTEM SENSOR 95CD CEILING HORN -STROBE 1 0.0001 0.1941 0.0001 0.388 TOTAL CURRENT CIRCUIT L3 0.750 CIRCUIT #4 - SPARE 0 SCR -15 SYSTEM SENSOR 15CD CEILING STROBE 0.000 0.066 0.000 0.000 0 SCR -30 SYSTEM SENSOR 30CD CEILING STROBE 0.000 0.094 0.000 0.000 0 SCR -95 SYSTEM SENSOR 95CD CEILING STROBE 0.000 0.181 4.000 0.000 0 PC2R-15 SYSTEM SENSOR 15CD CEILING HORN -STROBE 0.000 0.079 0.000 0.000 0 PC2R-75 SYSTEM SENSOR 75CD CEILING HORN -STROBE 0.000 0.176 0.000 0.000 0 PC2R-95 SYSTEM SENSOR 95CD CEILING HORN -STROBE 1 0.0001 0.194 .0.0001 0.000 TOTAL CURRENT CIRCUIT 14 0.000 TOTAL ALARM CURRENT 2.496 TOTAL SUPERVISORY CURRENT 0.140 TOTAL STANDBY HOURS 24 TOTAL SUPERVISORY CAPACITY 3.360 ALARM PERIOD IN MINUTES 10 TOTAL ALARM CAPACITY 0.416 TOTAL ALARM AND SUPERVISORY CAPACITY 3.776 TOTAL AMP -HOURS REOUIRED AFTER 20% DERATING 4.531 PROVIDE TWO (2) 12V-7.5AH BATTERIES FACP VOLTAGE DROP CALCULATIONS CIRCUIT #1 VOLTAGE APPLIED VOLTS 20.4 WIRE RUN LENGTH FEET 50 WIRE RUN CURRENT AMPS 0.031 WIRE SIZE AWG 14 VOLTAGE DROP % 0.05% END OF RUN VOLTAGE VOLTS p J O Q Q 20.39 i - F o d U) CIRCUIT #2 LL VOLTAGE APPLIED VOLTS 0 WIRE RUN LENGTH FEET 244 WIRE RUN CURRENT AMPS 1.125 WIRE SIZE AWG 14 VOLTAGE DROP X 8.26% END OF RUN VOLTAGE VOLTS 18.71 CIRCUIT #3 VOLTAGE APPLIED VOLTS 20.4 WIRE RUN LENGTH FEET 202 WIRE RUN CURRENT AMPS 0.750 WIRE SIZE AWG 14 VOLTAGE DROP X 4.56% END OF RUN VOLTAGE VOLTS 19.47 CIRCUIT #4 - SPARE VOLTAGE APPLIED VOLTS - WIRE RUN LENGTH (FEET) - WIRE RUN CURRENT (AMPS) - WIRE SIZE (AWG) - VOLTAGE DROP X -% END OF RUN VOLTAGE VOLTS - ec 2121 N.W. THURMAN PORTLAND, OR 97210 503 224 .3511 www.e-c-co.com REVIEWED BY: ERIC PUSKAS NICET 94139, LEVEL III CET FIRE ALARM SYSTEMS DATE: 8-3-13 SCALE: NO SCALE DRAWN BY: NLH PROJECT NUMBER: SHEET: 2OF2 L F - LL! W LU g W oe p J O Q Q N zxo F-4 m i - F o d U) iY O F- LL 0 REVIEWED BY: ERIC PUSKAS NICET 94139, LEVEL III CET FIRE ALARM SYSTEMS DATE: 8-3-13 SCALE: NO SCALE DRAWN BY: NLH PROJECT NUMBER: SHEET: 2OF2 L