Loading...
Plans (4) BUP2015 - 00279 li RECEIVED SW Locust Street — tt +_ - ._. - t SEP 2 9 2015 _. ilt ( AREA OF WORK P . . r! !r _.. . ,. UVS-- BUILDING DIVISION Architecture InteriorLsZ:. ITY , b MIN 11- @111MMM r - � l,r4rltitl.t'IiTk iPlanning Engineering!,li I} - ? STRUCTURED PARKING i ! T,, rz l� l l. g i 4 'i i 1 k!It -\ 0 •- ! •: �. i ,_ ;� "y'y j lJtlr;..i.l'..I..l;yl'�....Ii1Ii�!it�\�'j � Portland,OR ~~ ! 503.224.9560 �.- _ �, _.r-7 .- r� �v_ Vancouver,360.695.7879 i Seattle WA 206.749.9993 o TENANT IMPROVEMENT www.mcknze.com _ _ j! MACKENZIE i r' ! j �' Ifr F.:: �1,�.itt1\\«!\t i�•\t`1:i 1:�ti r/,1 �J.Y«,j� ^�' F ._; ' ' f fat r-. �; fit u'� �r � ��� � �_�! til t' r' � LINCOLN, DESIGN DRIVEN I CLIENT FOCUSED r. i ( "�;, a ',l ! Client C . 10200 SW GREENBURG ROAD - TIG OREGON I S H O R E T E I IV Ill _ STRUCTURED PARKING S UC�TURED PARKIN ! _ _____-- _-. ___._ _ ,► " INDEX OF DRAWINGS ' SW Oak Street ect % T1.1 TITLE SHEET, CODE PLAN, SITE PLAN AND NOTES BRIDGEWELL ° 26 50' 100, 200' A2.1 PARTIAL FIFTH FLOOR PLAN, REFLECTED CEILING PLAN AND NOTES RESOURCES LLC A8.1 DETAILS AND SCHEDULES SUITE 500 1 SITE PLAN TENANT IMPROVEMENT T11 LINCOLN CENTER NTS 5 UNCOLN TRUE PLAN SCOPE OF WORK 1020011SW REGON RD NORTH NORTH SCOPE TO OCCUR WITHIN AN EXISTING FULL FLOOR TENANT ON THE FIFTH OF SEVEN FLOORS. WORK TO INCLUDE NEW WALLS, DOORS AND RELITES. TENANT APPROVAL: �� ,AUL . KI NO C� .DISTANCE BETWEEN TWO PORT DE 17N EXITS: 99'-2" DESIGN/CODE DATA , 1/3 OF DIAGONAL: GOVERNING CODE: 2014 OSSC 62'-4" ?� OF OCCUPANCY: B CONSTRUCTION TYPE. TYPE I—B ``1' TENANT AREA (APPROX): APPROX. 16,094 S.F. © MACKENZIE 2015 OCCUPANCY LOAD: 161 ALL RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE 2 REQUIRED EXITS, 2 EXITS PROVIDED USED OR REPRODUCED IN ANY MANNER,. ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE WITHOUT PRiOR WRITTEN PERMISSION AREA OF WORK BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION REVISIONS: WITH ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER Z oQ 2< REVISIONS REVISION DELTA DEFERRED SUBMITTAL THIS CLOSING DATE �o SHEET i 1 EXIT I 2014 OSSC SECTION 107.3.4.2 (by separate permit) ' FIRE SPRINKLER ` FIRE ALARM o ati¢a MECHANICAL ELECTRICAL EXIT i NOTE: DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS ARE SCHEMATIC ONLY: THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT 9 f 13 3. DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW SHEET TITLE: PRIOR TO SUBMITTAL TIME SHEET, CODE PLAN, VALUATION SITE NOTES PLAES AND Now# VALUATION OF WORK = $16,000 CITY OP TIGAM *BUILDING IS COMPLIANT REVIEWED FOR CODE COMPLIANCB Approved: �l DRAWN BY: KJF I'ertnit#: 5- - -' Address: (( CITY OF TIGARD CHECKED BY: SBH, PDK Suite#: r'"Q� c� r - Approved by Planning By; Dain l (215�t1(� Date: q"a `'. '0 I s SHEET: 2 CODE PLAN t / / fis— Initials: 1 FIFTH FLOOR 1/16 = 1'-0" TRUE PLAN OFFICE COPS.. ' Til BRIDGEWELL NORTH NORTH RESOURCES LLC JOB NO. 2150950.04 0.2150950.04 PERMIT SET-- 09-23-15 *215095004• C:\TEMP\ACPUBLISH_5860\04—TI.I.DWG KJF 09/22/15 12:39 1:96.00 LEGEND ===? ===== EXISTING CONSTRUCTION TO BE DEMOLISHED y �t EXISTING WALL TO REMAIN NEW WALL TO UNDERSIDE OF GRID, SEE 3/A8.1 Architecture Interiors EXISTING 2 HOUR RATED WALL TO REMAIN Planning Engineering EXISTING OUTLET AND TELEPHONE/DATA ROUGH IN LOCATION EXISTING QUADRUPLEX OUTLET EXISTING COVERPLATE LOCATION TO RECEIVE NEW VOICE/DATA ROUGH IN LOCATION EXISTING COVERPLATE LOCATION TO RECEIVE NEW DUPLEX OUTLET Portland, OR EXISTING BASE FEED TO REMAIN 503.224.9560 Vancouver,WA ® NEW BASE FEED, (1) CIRCUIT PER (4) WORKSTATIONS 360.695.7879 ® NEW BASE FEED, (2) CIRCUITS Seattle,WA r 206.749.9993 EXISTING LIGHT SWITCH ...... www.mcknze.com __.—_.___.. ____ �� NEW OUTLET AND .VOICE/DATA ROUGH IN LOCATION MACKENZI Ep ks NEW LIGHT SWITCH WITH OCCUPANCY SENSOR DESIGN DRIVEN I CLIENT FOCUSED Client DOOR NUMBER SYMBOL r/1 _. _ _. _. _ .-.---...... EXIT REQUIRED EXIT EXISTING CEILING GRID Ot S H O R E S T E I N r- EXISTING 2'x4' LIGHT FIXTURE TO REMAIN EXISTING 2x4 LIGHT FIXTURE TO BE RELOCATED � 501 S <; NEW OR RELOCATED 2'x4' LIGHT FIXTURE Project BRIDGEWELL 5 ` ' i EXISTING SUPPLY/RETURN VENT TO REMAIN RESOURCES LLC SUITE 500 OFFICE ; TENANT �- �--- - - �� 2 501 1 -' -` �Y EXISTING SPRINKLER HEAD LOCATION TO REMAIN IMPROVEMENT EXISTING SMOKE DETECTOR TO REMAINx M'mx 5 LINCOLN - - 10200 SW GREENBURG RD _. . 'a TIGARDit EXISTING DIRECTIONAL MIRROR 714'—11 OREGON L44 MIN ! EXISTING EXIT SIGN 01 CLR. I EXISTING FIRE STROBE OPEN OFFICE EXISTING FIRE PULL ALARMAU D. KI I C� EXIT ._ EXISTING FIRE EXTINGUISHER ►�� �• ';'; EXISTING THERMOSTAT ��PORT D, R ,GON OF O 7 3 14'-11" rYP. � � GENERAL NOTES MACKENZIE X0,5 © ALL RIGHTS RESERVED A A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE.30M COM THESE DRAWINGS ARE TfIE PROPERTY — ! — B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. OF MACKENZIE AND ARE NOT TO BE C. WALL THICKNESSES ARE NOMINAL, UNLESS NOTED OTHERWISE. USED OR REPRODUCED IN ANY MANNER, I IU WITHOUT PRIOR WRITTEN PERMISSION D. SUSPENDED ACOUSTICAL TILE CEILINGS AT 8'-9"± (EXISTING) AFF, UNLESS NOTED OTHERWISE. _ _ .. .. 2 1 E. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAILS 1/A8.1. REVI I 44"MINv F. CENTER ALL DOWN LIGHTS, FIRE SPRINKLER HEADS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF 2X2 REVISIONS: OFFICE �� ��-'�. s'; ; I CLR. 503 TILE, UNLESS NOTED OTHERWISE. o 5 G. ELECTRICAL, DATA AND SWITCHING LOCATIONS ARE SHOWN TO CONVEY GENERAL INTENT ONLY. COORDINATE 2Q REVISIONS REVISION DELTA > THIS CLOSING DATE B ELECTRICAL/DATA/SWITCHING REQUIREMENTS WITH TENANT AND PROVIDE DRAWINGS BY DEFERRED SUBMITTAL. �o SHEET Ah--- H. FURNITURE IS SHOWN FOR SCHEMATIC PURPOSES ONLY. TENANT OR TENANT'S VENDOR TO CONFIRM BUILT CONDITIONS FOR SPATIAL 5 FS S REQUIREMENTS AND FINAL LAYOUTS. DUE TO SLIGHT CAD BASE DISCREPANCY DISCOVERED DURING SITE VERIFICATION DATED 09-21-15, FURNITURE VENDOR TO FIELD VERIFY AREAS OF FURNITURE RECONFIGURATION (TO ENSURE REQUIRED CODE CLEARANCES ARE MET) PRIOR TO FINAL FURNITURE 6 PLAN BEING APPROVED BY TENANT. I. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. CONTRACTOR IS RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON. J. ALL INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE. O K. ALL INTERIOR DOORS TO BE SOLID CORE FLUSH WOOD DOORS TO MATCH SUITE STANDARD UNLESS NOTED OTHERWISE. \ 0 L. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. SITE OBSERVATION HAS BEEN PERFORMED AT AREAS OF WORK ONLY (ON 09/21/2015, WHILE OCCUPIED) AND PLAN, ELECTRICAL AND CEILING INFORMATION HAS BEEN UPDATED (OBSERVATION IS LIMITED TO VISIBLE/ACCESSIBLE AREAS). CONTRACTOR TO FIELD VERIFY AND CONFIRM ADDITIONAL REQUIREMENTS WITH TENANT. — `' " SHEET TITLE: y M. NO VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS FINISH PRODUCTS. N. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE PROVIDED BY THE ELECTRICAL PARTIAL FIFTH 7 " CONTRACTOR AND IS DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING INFRASTRUCTURE IN CEILING. FLOOR PLAN, TY . O O 0. ALL DIMENSIONS SHOWN AS PLUS/MINUS (±) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. VERIFY AND CONFIRM ALL 0 DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF REFLECTED WORK. CEILING PLAN > , O O P. REPLACE DAMAGED AND SOILED CEILING TILES WHERE AFFECTED BY CONSTRUCTION TO MATCH EXISTING. AND NOTES Q. ADD SOUND INSULATION IN ALL NEW WALLS. 1 PARTIAL FIFTH FLOOR PLAN 2 REFLECTED CEILING PLAN KEYNOTES A2.1 1/8 1'-o" �2. 1/8„_1,_0„ - DRAWN BY: KJF 1. ALIGN NEW WALL WITH EDGE OF EXISTING COLUMN. PROVIDE FLUSH TRANSITION. 2. NEW 2'-0” WIDE RELITE TO MATCH EXISTING SUITE STANDARDS. SEE DETAIL 4/A8.1. CHECKED BY: SBH, PDK 3. CAP EXISTING BASE FEED LOCATIONS. ==- - ---- 4. NO WORK THIS AREA. SHEET: 5. CONFIRM FEASIBILITY OF SWITCH PLACEMENT. RELOCATE PLACEMENT IF REQUIRED TO MATCH SUITE STANDARD PRIVATE OFFICE SWITCH LOCATION. 6. RELOCATE EXISTING FIRE STROBE AS REQUIRED PER CODE. 7. FURNITURE, EQUIPMENT AND WORKSTATIONS, NIC (BY OTHERS). FURNITURE IS SHOWN FOR CONCEPTUAL PURPOSES ONLY WHERE A 2 .1 INDICATED BY HALF TONED LINES. TENANT AND/OR TENANT'S FURNITURE VENDOR TO CONFIRM BUILT CONDITIONS FOR SPATIAL REQUIREMENTS AND FINAL LAYOUTS. CONTRACTOR TO COORDINATE POWER/DATA REQUIREMENTS, SPECIFICATIONS AND FINAL LOCATIONS PRIOR TO INSTALLATION. 8. RE—BALANCE HVAC AS REQUIRED. CONFIRM FINAL SCOPE OF WORK WITH TENANT AND LANDLORD. JOB N0.215C)950.04 PERMIT SETS 09-23-15 --- ----------._- 215095004\4-DRAWINGS\ARCHITECI'URAL\04-A2.1.DWG KJF 09/22/15 15:45 1:96.00 FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO 7/8" WALL ANGLE AT 2 BERC 2 ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 8" MAX. CLIP SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT LIMITING ��� ��'��� ����� STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER o ATTACH STUD TRACK ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS INTERIOR NON STRUCTURAL NON-COMPOSITE WALLS L/240 ® 5psf THROUGH GRID TO WITHIN 8" OF PERIMETER BRACE ABOVE LATERAL BRACING WITH APPROVED VERTICAL ® DESIGNATION SPACING MAX. WALL HEIGHT \ wry ~/8 ° ° ° ° 250S125-18 24" 8'-4" ASSEMBLY SUSPENDED \ \ \ / / COMPRESSION STRUT AT 12'-0" OC EA WAY /// rCOUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB ° ° Architecture Interiors 250S125-18 16" 9'-7" "ATTACHED ° °� ° 250S125-27 24" Engineering 45' Planning � WALL" ° °e 250S125-18 16" 11'-3" CJO CUT TILE FOR TIGHT METAL STUD BRACING 362S125-18 24" 13'-5" f�IUNC EDS AT WALL FIT AT WALLS TO FLOOR STRUCTURE AT 8'-0" A 3625125-18 16" 14'-4" OC W 2 A NOTE: FOR UNATTACHED WALLS PROVIDE A 1/2" CASING BEAD SCREWS(AT#EACH END. SIZING Portland,OR TO 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP 362S162-33 16" 16'-5" USG 200—A PER SPAN TABLE. BRACING TO SIZING 503.224.9560 -- DO NOT SCREW BERC 2 CLIP TO TRACK Vancouver,WA 362S162-43 16" 18'-0" SOUND ATTENUATION PROVIDED WHERE DISTANCE BETWEEN 360.695.7879 �` AT ALL NEW WALLS, TYP. TABLE MAX. LENGTH 600S162-33 16" 24'-6" � PERPENDICULAR INTERSECTING WALLS � — CROSS RUNNERS FIT BETWEEN MAIN RUNNERS » » OR HORIZONTAL BRACING BETWEEN Seattle,WA 1/2 DIA CONDUIT (EMT) 5 —10 206.749.9993 MAIN RUNNERS AT 4'-0" OC ,� INTERIOR NON STRUCTURAL NON-COMPOSITE WALLS WALLS EXCEEDS 8'-0" OC 6 —0 MAX SUPPORT WITH #12 WIRE AT 4 —0 OC OR 3/4" DIA CONDUIT EMT 7 —8 L/360 ® 5psf www.mcknze.com WITH CERAMIC TILE FACING METAL STUDS SEE WALL HEIGHT 1" DIA CONDUIT EMT 9'-9" GYP BD EA SIDE WITH #10 WIRE AT 5'-0" OC EA WAY SGL 162S125-33 MTL STUD 12'-0" TABLE FOR GAUGE AND SPACING LATERALLY BRACE MAIN RUNNER TO 1-5 8"x2OGA DESIGNATION SPACING MAX. WALL HEIGHTMACKENZIE, CONT ACOUSTIC SEALANT DESIGN DRIVEN I CLIENT FOCUSED NOTE: STRUCTURE AT 12'-0" OC EA WAY. BACK TO BACK 162S125-33 15'—O" 362S125-18 16" 12'-4" EA SIDE AGAINST TRACK ALL GRID MEMBERS AND BEGIN BRACING WITHIN 6'-0" OF MTL STUDS 1-5 8"X2OGA 362S125-33 16" 14'-3" j� / „ NO SEALANT AT SIM COND Client CONNECTION DEVICES TO BE OF AN PERIMETER AND 2" FROM CROSS MEMBER SGL 250S125-33 MTL STUD 13'-6" � 1/22? MAX IL APPROVED TYPE AND HAVE A 180# IN AREAS GREATER THAN 1,000 SF 2-1 2"x2OGA ¢ BOTTOM TRACK TO FINISH CAPACITY. ALL LATERAL BRACING SECURE ALL HANGERS TO BLDG WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH ti STRUCTURE. TRAPEZE DUCT WORK BACK TO BACK 250S125-33 15 —0 CONCRETE SLAB—Z ' LAB FLOOR W/ POWDER DRIVEN WIRES 70 HAVE A 200 CAPACITY. 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. i-- # AND OTHER LARGE OBSTRUCTIONS MTL STUDS (2-1/2"x2OGA) ANCHORS AT 4'-0" OC 1 SUSPEN®E® �EILI, \G �/-\�I�� Z L W/-RLL �EIGI ®� �/-\�LE L"-:j ® I WALL S H O R E 5 T E I M I J ( NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS 0 -1 �M) AT FLOOR AND SUSPENDED CEILINGTHAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. vA�•1 — SOUND ATTENUATION BATT /^ AS OCCURS Project GYP BD WALL AS OCCURS SRIDGEWELL RESOURCES LLC T — — — SUITE 500 TENANT H E D U L. E IMPROVEMENT For- 5 LINCOLN DOUBLE STUD AT JAMB, TYP DOOR DOOR DOOR FRAME HDWR 02Q0 WW GREENBURG RD DOOR OPENING SIZE THK TYPE MAT'L FINISH MAT'L FINISH DETAILS GROUP RATING COMMENTS TIGARD, OREGON 501A 3'—O"x8'-7" 1%" FL/R SC S HMK FF 4/A8.1 H-1 -- -- 503A 3'-0"x8'-7" 1%" FL/R SC S HMK FF 4/A8.1 H-1 -- -- METAL DOOR FRAME TO HARDWARE GROUPS: ABBREVIATIONS: MATCH SUITE STANDARD H-1: LOCKING OFFICE EXIST EXISTING J LOCKSET F82 GRADE 1, FF FACTORY FINISH AUL D. SLi�I CL BUTTS, SEAL, STOPS FL/R FLUSH WITH ADJACENT RELITE C� bi UJ HMK HOLLOW METAL KNOCKDOWN S STAIN PORT ND`, OREGON SC SOLID CORE WOOD OF © MACKENZIE 2015 ALL RIGHTS RESERVED SIDE LIGHT AS OCCURS THESE DRAWINGS ARE THE PROPERTY WITH 1/4" TEMPERED GLASS DOOR SCHEDULE NOTES: OF MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED 1N ANY MANNER, Li A. ALL DOORS/CLOSURES TO BE CHECKED, ADJUSTED, WITHOUT PRIOR WRITTEN PERMISSION AND/OR REPLACED TO BE IN COMPLIANCE WITH ADA. B. ALL TENANT ENTRY DOORS TO RECEIVE A NEW DOOR REVISIONS: N WITH MORTISE LOCKSET AS DETERMINED BY LANDLORD. z r4P INTE R DOOR w C. ALL SECONDARY DOORS TO HAVE DEADBOLTS REMOVED, �< REVISIONS REVISION DELTA INSTALL COVERPLATES OR CHANGE DOORS AS AVAILABLE. I'W SHEET THIS CLOSING DATE �8- HEAD SIMILAR 3"=1'-0" o D. ALL DOORS, FRAMES AND HARDWARE TO MATCH TENANT o SUITE STANDARDS. E. VERIFY DOOR HEIGHT DIMENSIONS. APPROXIMATE MEASUREMENTS BASED ON FIELD OBSERVATION. F. NEW DOORS MAY BE PULLED FROM EXISTING BUILDING INVENTORY OR RELOCATED WITHIN SUITE WHERE POSSIBLE. R RI N ISH S C H E DUL. ROOM FLOOR BASE N. WALL E. WALL S. WALL W. WALL CEILING SHEET TITLE: ROOM NAME MAT'L MAT'L MAT'L MAT'L MAT'L MAT'L CEILING FINISH DETAILS NO FINISH FINISH FINISH FINISH FINISH FINISH HT. MAT'L COMMENTS AND 501 OFFICE EXIST EXIST EXIST EXIST GB/P GB/P EXIST EXIST SCHEDULES 502 OPEN OFFICE EXIST EXIST GB/P GB/P GB/P EXIST EXIST EXIST 503 1 OFFICE EXIST EXIST GB/P EXIST EXIST GB/P EXIST EXIST FINISH SCHEDULE NOTES: ABBREVIATIONS: A. EXISTING CARPET AND RUBBER BASE TO REMAIN. NEW EXIST EXISTING RUBBER BASE AT NEW WALLS ONLY AND/OR ENTIRE GB GYPSUM BOARD WALLS/ROOMS WHERE AFFECTED BY CONSTRUCTION TO P PAINT MATCH EXISTING DARK RUBBER BASE. DRAWN BY: KJF B. PAINT NEW WALLS ONLY AND/OR WALLS/ROOMS WHERE AFFECTED BY CONSTRUCTION TO MATCH CHECKED BY: SBH, PDK EXISTING ADJACENT PRIVATE OFFICE WALL COLOR. SHEET: A8.1 JOB N0.2150950.04 PERMIT SET: 09-23-15 215095004\4_DRAWINGS\ARCHITECTURAL\04-A8.1.DWG KJF 09/22/15 15:23 1:96.00