Plans (3) BUP2015 00276
123'-10" Deferred Submittals Keynotes
1. MECHANICAL
2. ELECTRICAL 1. JANITOR SINK - SEE DETAIL 4/A2 .,.,.b,,,,,�
3. SPRINKLER 2. FULL HEIGHT DEMISING WALL
4. FIRE ALARM 3. J" GYPSUM BOARD CEILING AT 8'-0" AFF MILDREN DESIGN GROUP, P.C.
- 4. N STRUCTURE ARCHITECTURE ■ SPACE PLANNING
FE-]t5. EXISTING LIGHTED EXIT SIGN
28 SF � 7650 S.W. Beveland, Suite 120
Tigard, Oregon 97223-8692
(503) 244-0552
E Finish Room Symbol Legend •nish Schedule
ROOM NAME RECEIVEP
5 I OFFICE ROOM NUMBER Floor Finish ROOt4BB9ME
ROOM AREA/LOAD 101 ROOM FINISH SEP 17 2015
8,933 SF FACTOR B4BB9�- A. SHEET VINYL
l,iTWHI(>tARU
XXX/100:2�— B. SEALED CONCRETE
B:2 E I TS NUMBER OF BUILDING DIVISION
I ��OCCUPANTS X. EXISTING TO REMAIN
OCCUPANCY GROUP PER NUMBER OF Base
I
IBC TABLE 1004.1.2/NUMBER EXITS PROVIDED 0 NO BASE
i I 4" RUBBER BASE
° ° ° ° I 6" RUBBER BASE
i X. EXISTING TO REMAIN
RETAIL '
104 I Wall Finish
X A 0 X/A XX i
8213.69 S.F. I A. GYPSUM BOARD AND PAINT
/100 = 82.14 I d B. 4' PLASTIC WAINSCOT WITH ALUMINUM STEEL
M:EXITS 2
i TRIM AT EDGES, W.R. GYPSUM BOARD AND
PAINT ABOVE. TYPICAL AT ELEVATED WALLS W 305 R
NO OCCUPANCY UNDER THIS PERMIT ONLY •: •
i 4 X. EXISTING TO REMAIN ,
I
7'-6„ ELECTRICAL ZJANITOR I Ceiling Finish
OF
102 i A. GYPSUM BOARD AND PAINT
MIN. CLR. B4AXX �
60.7 S.F. I X. EXISTING TO REMAIN
3 EXEMPT ° ° ° ° !
A2 Gelling height Client:
108 1 '
I4 8. 8'-0" Paul
! X. EXISTING TO REMAIN
00 MEN
103 Schatz
A6BA8
108 47.81 S.F.
}y
EXEMPT ' 1
A2 3
x yt
•:-'A2 z
. . ; . . WOMEN _ General Notes
104 ' , �' � k `t{;�
A6BA8 2 3 `*r. a e A. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS
6600 SW Bonita Rd.
"to EXIT TRAVEL DISTANCE=119 -9 Tigard, Oregon 97223
47.98 S.F. • ARCHITECT OF ANY DISCREPANCIES g g
Y •'j'� NOTIFY AR NCIES PRIOR TO START
I08 � z EXEMPT •-- -- -- -- -- -- -- -- -- -- -- . .�• }
Hj1, OF WORK.
- - B. ALL HARDWARE IN ACCORDANCE WITH ANSI 117.1.
C. PROVIDE (1) APPROVED FIRE EXTINGUISHER WITH RATING OF Project:
NOT LESS THAN 2-A: 10B FOR EACH 3,000 SQ.FT. OF FLOOR Tenant
AREA TRAVEL FROM ANY PORTION OF BUILDING NOT TO
Floor Plan Partial Reflected Ceiling Plan EXCEED 75'. Improvement
D. 100% SPRINKLERING TO BE MAINTAINED THROUGHOUT IN
8,214 SF ACCORDANCE WITH N.F.P.A. PAMPHLET #13 (BY SEPARATE
0 2 4 8 16 274 OCCUPANTS 0 2 4 8 16
PERMIT).
E. PROVIDE SIGN AT MAIN EXIT DOOR PER IBC 1008.1.8.3, 2.2
STATING "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING
Door Hardware IS OCCUPIED". 6600 SW Bonita Rd.
Door Schedule F. LEVEL 4 FINISHED WALLS TO RECEIVE (1) COAT PRIMER, (2) Tigard, Oregon 97223
AREA OF WORK
NOMINAL SIZE DOOR FRAME GROUP 1 GROUP 2 COATS ACRYLIC LATEX. LEVEL OF GYPSUM BOARD FINISH TO
MARK WIDTH HEIGHT THICK Type MAT'L FINISH MAT'L FINISH GLAZING HRDW. REMARKS 1X PAIR BUTTS 1Y2 PAIR BUTTS - _ 7 - _ _ BE PER ASTM C840. (ALL NEW WALLS)
A108Z 3'-0" 7'-0"- 1 3 4' A SC ST MTL FF -- 2 -- 1 LOCKSET 1 MORTISE PRIVACY LOCKSET WITH OCCUPANCY INDICATOR I I I I I I I I G. PROVIDE ADA SIGNAGE AT TOILET ROOMS AND ADA COMPLIANT Sheet Title.
A108Z 3'-0" T-0" 1 314' A Sc ST MTL FF 1 2 -- 1 GASKET 1 GASKET I I I EXIT SIGNAGE.
A108Z 3'-0 7'-0 1 314" A SC ST MTL FF -- 1 -- 1 STOP 1 KICKPLATE III I I U I I I U I I I I IH.i WOOD STUDS AT CONTRACTfPG , Floor Plan,
LEGEND 1 CLOSER - -
1 STOP
I. PROVIDE OUTSIDE =VlifiVVfttbfffi�
C � ECODE
FF FACTORY FINISH I (BY SEPARATE PE
- ��. 3 I , �Jc � _ Site Plan,
MTL METAL DType ( � 4 '- OTC.
Door �
SC SOLID CORE yp
ST STAIN ! penult Notes
� ��abt �-��7
Addreenhn
p
g I Suite#t
BY: Datea �Z l� 7
I �
Code Analysis
°' • � OFFICE COPY
BASED ON THE 2014 OREGON STRUCTURAL AND SPECIALTY CODE
OCCUPANCY AND CONSTRUCTION PER IBC 304.1, 311.2 AND 602.3 \ I 11 Revisions:
EXISTING OCCUPANCY. M ► (�l �� �J�C/
PROPOSED OCCUPANCY: M - NO CHANGE I SITE VV
CONSTRUCTION TYPE: III-B ickplate where Existing
INTERIOR FINISH CLASS C: PER IBC SECTION 803.1 A scheduled Buildin W �'; ' '" '`' all
FLAME SPREAD INDEX: 76-200
--)
SMOKE DEVELOPED INDEX: 0-450
OCCUPANCY REQUIREMENTS
i ,��„�, .4�F^µG� r�•�;� CITY OF TIGARD
M OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT EXCEED 75'-0"
PER OSSC TABLE 1014.3 _ _ I - if by Planning
EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 250'-0" PER OSSC TABLE 1016.2 ;
,. : Date: q/ ! 1 / (S
EGRESS ILLUMINATION PER SECTION 1006
Initials: i/ (�
MEANS OF EGRESS, INCLUDING EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING
IS OCCUPIED. PROVIDE MINIMUM 1 FC ILLUMINATION AT THE FLOOR LEVEL.
EMERGENCY LIGHTING IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL I r MILDREN DESIGN GROUP, P.c., 2015, ALL
; �' RIGHTS RESERVED
AUTOMATICALLY ILLUMINATE EXIT ACCESS CORRIDORS, PASSAGEWAYS AND AISLES AND THE PORTION -
*; {{ «.
OF THE EXTERIOR EXIT DISCHARGE IMMEDIATELY ADJACENT TO EXIT DISCHARGE DOORWAYS WITH , f THESE DRAWINGS ARE THE PROPERTY OF
r j � k ; MILDREN DESIGN GROUP, P.C., AND ARE
THE EXIT ILLUMINATION SUPPLEMENTED WITH AN EMERGENCY POWER SUPPLY CAPABLE OF PROVIDING NOT TO BE USED OR REPRODUCED IN ANY
MANNER, EXCEPT WITH THE PRIOR WRITTEN
POWER FOR A DURATION OF NO7 LESS THAN 90 MINUTES PER OSSC SECTION 1006.3. t• •i' PERMISSION OF MILDREN DESIGN GROUP, P.C.
PLUMBING FIXTURE CALCULATIONS - + ��' ' Date: 17 September 2015
OCCUPANT LOAD: PER UBC TABLE 2902.1 Drawn by: Checked by:
MERCANTILE: 8,214 SF 500 SF/PERSON 274 PERSONS = 137 MEN, 137 WOMEN
Site plan Vicinity Map BK WEM
PLUMBING FIXTURES Not to Scale Not to Scale Job Number: 114176.02
REQUIRED MEN REQUIRED WOMEN TOTAL PROVIDED: Sheet
WATER CLOSET: 1 1 1
LAVATORY: 1 1 1
Permit Submittal - September 2015 Al
BATT INSULATION THICKNESS
7 TO MATCH STUD DEPTH
2x BLOCKING AS REQUIRED
2' DEEP, 18 GA TOP TRACK.
DO NOT SCREW GYPSUM
MILDREN DESIGN GROUP, P.C.
BOARD TO TRACK ARCHITECTURE ■ SPACE PLANNING
%" GYPSUM BOARD 7650 S.W. Beveland, Suite 120
AT EACH SIDE Tigard, Oregon 97223-8692
(503) 244-0552
24" 0/C STUD CHART:
•362 S 125-18 TO 9'-11"
•362 S 137-33 TO 17'-6"
•400 S 162-33 TO 19'-10"
BATT INSULATION THICKNESS •600 S 162-33 TO 27'-7" 3/4" PLYWOOD AT WATER
TO MATCH STUD DEPTH LL SEE A/E FOR ALTERNATE HEATER STAINLESS STEEL MOP & BROOM HOLDER
SIZES
2" DEEP, 18 GA TOP TRACK. 6" X 22 GA METAL JOIST AT
" 0 C PLASTIC LAMINATE WAINSCOT
16
DO NOT SCREW GYPSUM /
` BOARD TO TRACK 3/4" PLYWOOD AT WATER 5/8" GYP BD FASTEN TO
— 5�" GYPSUM BOARD HEATER STUDS AND JOISTS WITH
AT EACH SIDE TYPE "S" SCREWS AT 8" 0/C
PROVIDE FINISH TAPE AND 6" X 22 GA METAL JOIST AT AT PANEL EDGES AND 12"
PAINT BOTH SIDES 16
O/C
0/C AT INTERIOR SUPPORTS
4'-0" 4'-0"
5/8" GYP BD FASTEN TO
STUDS AND JOISTS WITH 5/8" WATER RESISTANT,
24" 0/C STUD CHART: TYPE "S" SCREWS AT 8" 0/C GYPSUM BOARD AT TOILET 6"
•362 S 125-18 TO 9'-11" ROOM SIDE CO
� 305-362 S 137-33 TO 17'-6" AT PANEL EDGES AND 12" R.
• 400 S 162-33 TO 19'-10" 0/C AT INTERIOR SUPPORTS 35/8" 25 GA STUD AT 24" •'.
•600 S 162-33 TO 27'-7" 0/C TYPICAL, 20 GA AT o 0 0 0
SEE A/E FOR ALTERNATE TOILET ROOM 16" 0/C WHEN SUPPORTING
SIZES
WATER HEATER OFI
HOLD GYPSUM BOARD 4'-0" R11 BATT INSUL AT TOILET
FROM FLOOR AT VACANT ROOM WALLS AND CEILING Client:
SIDE o
Do 6" RUBBER BASE Paul
POWER—ACTUATED FASTENERS:
FA*
gA
POWER—ACTUATED FASTENERS: POWER—ACTUATED FASTENERS: 4" RUBBER BASE •0.145"0 x 4" MIN. EMBED AT Schatz
12" 0/C WALL TO 22'-0"
*0.145"0 x MIN. EMBED AT •0.145"O x MIN. EMBED AT
12" 0/C WALL TO 22'-0" 12" 0/C WALL TO 22'-0" •0.145"0 x MIN. EMBED AT
6" 0/C, WALL TALLER THAN
•0.1450 x 4" MIN. EMBED AT -0.145"0 x MIN. EMBED AT 22'_0"
6" 0/C, WALL TALLER THAN 6" 0/C, WALL TALLER THAN JANITOR SINK
22'-0" 22'-0"
ri-'N� Full- Height Wall 2 Full Height Wall at Restrooms 3 Toilet Room Wall Section 4 Janitor Sink 6600 SW Bonita Rd.
A2 3"=I'—O" A2 3"=I'—O" A2 3"=1,-0" "=1 -0" Tigard Oregon 97223
1e2—r5 d—full height restroom wall-1 Ic—r4 d—JanitorRoom-1
Project:
FRAMED MIRROR— 2'-0" x 3'-0" PLASTIC LAMINATE Tenant
WAINSCOT AT THESE
ANSI 117.1 TYPE FAUCET PEERLESS, 4' CERRA, CRW7232. TWO WALLS ONLY Improvement
MOUNT AT 6'-6" A.F.F. VERTICAL GRAB BAR
V-6"
\
7
6
3'-0" 3�_4. 61500 SW Bonita Rd.
/ V-6" 1'-0" 3'-s'
1'-5" MI Tigard, Oregon 97223
o
I
°Q 3'-0"
Sheet Title:
\ Z Z Q P Details
O
C) ;, M
L14-4-
NNN
c° ACCESSIBLE TOILET
x
6" MAX. °'
TOILET TISSUE
BOBRICK B-369 PAPER DISPENSER
TOWEL DISPENSER/
WASTE RECEPTACLE GRAB BARS
INSULATE EXPOSED PIPING
Revisions:
('5` Toilet Room Elevation
Toilet Room Elevation 1 — floor mounted W.0 and wall mount lav
MILDREN DESIGN GROUP, P.C., 2015, ALL
RIGHTS RESERVED
THESE DRAWINGS ARE THE PROPERTY OF
MILDREN DESIGN GROUP, P.C., AND ARE
NOT TO BE USED OR REPRODUCED IN ANY
MANNER, EXCEPT WITH THE PRIOR WRITTEN
PERMISSION OF MILDREN DESIGN GROUP, P.C.
Date: 17 September 2015
Drawn by: Checked by:
WEM
Job Number: 114176.02
Sheet
Permit Submittal - September 2015 A2