Plans (15) e (-3 (.n ; FB4C LEGACY LINE FAN COIL h A SIZES 018 THRU 060 b a `} Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The FB4C fan coil has the proven technology of Bryant fan coil units with Puron® refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with oleo rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves TAO and product life, features homeowners appreciate. • Standard features include grooved tubing and louvered fins. Coil circuiting has also been updated to make the most of all Bryant • heat pumps and air conditioners. Units come with solid state fancontrols, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils. Units can • accommodate factory- and/or field-installed heaters from 3 to 30 Nep >tfkW. It also should be noted that the unique cabinet design of these fan coils meet stringent regulations for cabinet air leakage - a requirement of 2%cabinet leakage rate when tested at 1.0 inches of static pressure. The FB4C fan coil design is loaded with popular features.These fan coils utilize the latest in electronic commutation motor(ECM) technology through the use of high efficiency, multi-tap ECM motors allowing reliable air delivery with increased static pressure. It comes in a pre-painted (taupe metallic)galvanized steel casing and a factory-supplied power plug for ease of installation. The FB4C unit is shipped with a factory-installed Teflon-ring piston FB4CNF(018-048) or a Puron refrigerant TXV FB4CNF060, Al 0083 FB4CNP(01 8-060). STANDARD FEATURES • Multi-tap ECM(electronic commutating motor)motors-all sizes • Integrated motor controls,with 90-sec off TDR function,have replaced integrated circuit board • Five available speed tags to meet a wide range of applications • Large,grooved tube,louvered fin coils • Efficient,quiet,time-tested blower housings and diffusers • Sturdy,drainable condensate pans • Cabinet construction features innovations designed to prevent cabinet sweating • Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements • Super-thick R-4.2 insulation with vapor barrier • Pre-painted galvanized steel cabinet(taupe metallic) • Cabinet design meets stringent regulations for 2%cabinet leakage rate when tested at 1.0 inches static pressure • Installation-flexible,multipoise units • Horizontal hanging provisions on cabinet • No tools required to access filter • Newly improved filter rack area filter door insulation added for improved air seal • Factory-installed heater packages available on select models(5-through 15-kW) • 3-through 30-kW accessory heaters-field installed • Factory-supplied power plug • Easy plug-in provisions for heater installation • Entry options for high and low voltage wiring hook-up • Leak-preventing sweat connections • Puron refrigeration factory-installed Teflon-ring pistons on all FB4CNF(018-048)coils • Thermostatic expansion valve,TXV,on all FB4CNP coils and FB4CNF060 • Designed for manufactured housing applications. ADDITIONAL FEATURES • Factory-installed heater packages available on select models 2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 F B 4 C N F 0 1 8 0 0 0 Product Heating Size F = Fan Coil 00 = No Heat 05= 5 kW Type 75= 7.5 kW B = Base, Puron 08 = 8 kW 10= 10kW Position 11 = 11 kW 4= Multipoise 15= 15 kW Coil Type Series 0= Copper C T=Tin—plate L=Aluminum Electrical N = 208/230v, 1 ph,60 Hz Capacity 018 = 18,000 Cabinet Style 024 =24,000 F = Single Piece with piston (TXV on FB4CNF060) 030=30,000 P =TXV 036=36,000 042 =42,000 048 =48,000 060=60,000 A LI ru...I CERTIFIED(!) fn Use of thenAHRI CertiM1ea TM Mark tlicates a w Puron opaturers co us participation In the ,. '. oorogram For venM1cation , f oenriwtinn fw aiiaal U products,90 to nciractpryorg. ISO 9001 OkIFSAI don.l D U RATE C H rh, 3 ELECTRICAL C3NFIANATISN SHIPPING XT MT SERIES CNARACTERSTICS A B C D E F G X SLOPE 'A' (HSI FB/CNP0181 A % • /2 11/16' 14 5/16' 12 7/16' 12 5/16' 10 1/16' 18 1/8' IB 5/8' - 12' % - 111 , FB/CNP02/L A % • 42 11/16' 14 5116' 12 7/16' 12 5/16' 10 1/16' 18 1/8' 18 5/8' - 12' % - 112 FB/CNP03DL A _ % • /9 5/8' 1T 5/8' 15 3/1' 15 5/8' 15 3/8' 23 1/8' 23 5/8' - 11' X - 122 11 --------I FEI011431L A % • 495/8' 175/8' 153/4' 155/8' 15 3/8' 231/8' 235/8' - 11' % - 122 FBICNP042L A X 49 5/8' 21 1/8' 19 1/1' 19 1/8' 15 11/16' 23 1/16' 23 1/8' X 157 iB4CMP018L A % • 49 5/8' 21 I/8' 19 1/1' 19 1/8' 15 11/16' 23 1116' 23 118' - - % 157 2_ e s FB4CNP060L D % - - -53 7/16' 21 1/8' I9 1/4' 19 1/8' 19 1/2' 27 1//' 26 15/16' % 175 7/8', 1 3/32' • a K=TFS 2'DIA. N.O.'S 0=N0 FOR HIGH VOLTAGE a •=TES, DUE 10 AVAILABLE FIELD POWER WIRING m 7/8'018. N.O. INSTALLED HEATERS. o 1 7/8' FOR LOW VOLTAGE „ N CONTROL WIRING Ill_ -A n NOTE: c E IIII 1 15/16' 1' NOTE:ALLOW 21'FROM FRONT g 1 3/8' 1.SERIES DESIGNATION IS THE 14TH POSITION FOR SERVICE ,.."... TOP VIEW OF UNIT PRODUCT NUMBER m m o 22 1/16' 2.ALL DIMENSIONS ARE IN'INCHES'UNLESS NOTED. 10 3/16' 11' 7/8' Ea B 2 118' 1 OUTLET AIR 3/1' RI Y=1 Nye 15/16'470 —� �Y� ��.,•/ DISCONNECT OR �I >S?b Sy L.,A CIRCUIT BREAKER •s(, "' y�N�I F LOCATION ALTERNATE Y. �r-y :LOWER.CONTROL, UNIT CONNECTION SIZES FOR HIGH/VOLTAGETA.N.O.'S b_ `j NOTE: NODULAR e. aLTERNATE POWER WIRING UNITS WILL HAVE 3 On NI b ELECTRIC HEATER SUCTION: 018 8 021- 5/8' I.O. SWEAT ACCESS PANEL 030 6 036- 3/1' I.D.l.D. SWEAT A TWO-PIECE O (' 042 THRU 060- 7/8'I.D. SWEAT 1/8'018. X.O. OPPOSITE SIDE }iF FOR LOW VOLTAGEWCABINET LIQUID: 3/8' I.D. SWEAT CONTROL WIRING CONDENSATE: 3//'FPT ;::m 2 OPTIONAL FIELD CONVERTED e LA b RIGHT SIOE RETURN OPENING 5c4 m 1 INLET AIA A (SLOPE COIL UNITS ONL91 V =-_ cD _ Cl riJ OIL ACCESS ` 1 1/2 a 0= ' PANEL _ _ o asge C S 2 5/8' /11/16' F:-..?.. - 1$5 N FITTING '° ill CONNECTION LINE ° E • LIQUID LINE ° !i ° ° o Y' �e v LIQUID LINE CONNECTION CONNECTION ■e i_ g ��� -O 3 1/16' CONNECTION i1i� A ' SUCTION LINE CONNECTION ° J .. iiNg 3E°a-a ��- - ° • 1 3/16' .. MAX H c : _ • �. • ® FOR MA .Il 19' MODULAR UNITS 10 7/16' ® SUCTION LINE v _ v / 10 3/1' CONNECTION Nil ° ° - !ii : • ) .• 6 3/16' bI" 111 M• ° • �, �e 4UMMEMMEMEND 01111111.111111111.10111111 5' FILTER ACCESS I OPENING ,�, OPENING PANEL ACCESS PANEL CONFIG FOR 1 1//'—.1 f. 19 13/16' 2 1/2• a J r I D SLOPE COIL DETAILS SLOPE COILS RIGHT SIDE VIEW CONNECTION LOCATIONS SHOWN DOWNFLOW OR HORIZ. _ FOR UPFLOW C HORIZ. RIGHT APPLICATIONS TJ INLET AIA LEFT APPLICATIONS INLET AIA a AND FRONT VIEW "A" COILS DOWMFLOW APPLICATIONS 0 v SHOWN WITH'A'COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS Q 1 MEASUREMENT- ENGLISH M o SD5206 1 MO "` mor 1 i A D A 0 00 a, NOiES SLOPE C 01 1 I. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN'INCHES' UNLESS NOTED. o )—1116• TYP. AIRFLOW 12 PLACESI. AIRFLOWI2 3/16' TYP. } 1 1 12 PLACES). 0 aaaaa Y PRIMARY DRAIN .E v TYP. 12 PLACES). 3 1/4' SECONDARY DRAIN F I G PRIMARY DRAIN oI I/4' SECONDARY DRAINPRIMARY DRAIN 1 IJ/16'+{ a SECONDARY DRAIN TYP.• ;-�� TYP6• — SEC ONDAAY DRAIN / DN O m 2$ m I PRIMARY DRAIN !..,',...4 o 4' CN IMO - 2 7/8` • �. SI 1 �� 1 518' l y Y6 N KED !•I 111 wv6.1 L i -I— _ _ ���• R aY M.+ 1 CO I/2' I /4' t I•TYP. (4/PLACES/. Ill' I• �a y A iYP.. II SIB' 219/16' 11 PLACES/.j +{ Z /8' /1' TYP,. �'I 1/8• I I, YAW 2 3/16' 3 1/4• 1 13/16' F TYP. yl Y n TTP•. 2 7/8' TYP. iYP.• Y 12 PLACES) DOWNFLOW ,Ti HORIZ. LEFT s UPFLOW egY z (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) HORIZ. RIGHT e CP - (FIELD CONVERTED) /Am4 Om 00y '11F t/i6'TYP. aZ CT to • HORIZONTAL MOUNT LOCATIONS -DIMPLES PROVIDED IN TOP PANEL. AIRFLOW 14 PLACES) AIRFLOW Y. m � AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED r 2 3/16'TYP. 1 J .136'DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. f 12 PL ACFS)• _ =a ,.1 + 1 et o a:L" O I' T 2 as a 1� El (2 PLA PIAC ES) E�� s R =a= "J' SECONDARY DRAIN F 4 3/4 G _Eo. s 70 PRIMARY DRAIN 3 1/16' I • SECONDARY DRAIN PRIMARY DRAIN o :? 8 — III netPRIMARY DRAIN 13/16' O 5/16' 0 V:-YE iYP• R.— 1 SECONDARY DRAIN aE'3 '.T SECONDARY DRAIN r TYP.' ifi ' 0 PRIMARY DAAIN� ? - • piO I'I1Py .i_ a $S S2 .IIO O 3' 1/B !':1.1 12 PLACES). : o 1112' _'J!!!! ,M I1} _i' )ITT • . T 9 ZiTP. I I/2'� J /8. LI6 .�•,3 1116' �2 I/16' 7/16' ICP,+{moi- S 7IB' i I 3/16' • 2'J -ti iYP• J um 4 314. (1 PLACES)• 7 7/B' TYP.. .. a 7/g• 13/16' 2 3116 13/16' ' TYP. 7 T/8 TYP (2 PLACESI• DOWNFLOW TYv. HORIZ. RIGHTrT18 IP 1 ! 1HORIZ. LEFT UPFLOW (FIELD CONVERTED) (FIELD CONVERTED) a . oO (AS SHIPPED) (AS SHIPPED) "a 0 s A C 0 I L MEASUREMENT- ENGLISH "" SD5158-4 zT D_ N N O FO • PHYSICAL DATA NOMINAL COOLING DIMENSIONS SHIPPING ORDERING NO. CAPACITY(Btuh) Height Width Depth WEIGHT FB4CN(F,P)018(0,T,L) 18,000 42-11/16 in. 14-5/16 in. 22-1/16 in. 112 lb 1084mm 363mm 560mm 51 kg FB4CN(F,P)024(0,T,L) 24,000 42-11/16 in. 14-5/16 in. 22-1/16 in. 112 lb 1084mm 363mm 560mm 51 kg FB4CN(F,P)030(O,T,L) 30,000 49-5/8 in. 17-5/8 in. 22-1/16 in. 122 lb 1260mm 447mm 560mm 55 kg FB4CN(F,P)036(0,T,L) 36,000 49-5/8 in. 17-5/8 in. 22-1/16 in. 122 lb 1260mm 447mm 560mm 55 kg FB4CN(F,P)042(0,T,L) 42,000 49-5/8 in. 21-1/8 in. 22-1/16 in. 157 lb 1260mm 536mm 560mm 71 kg FB4CN(F,P)048(0,T,L) 48,000 49-5/8 in. 21-1/8 in. 22-1/16 in. 157 lb 1260mm 536mm 560mm 71 kg FB4CN(F,P)060(0,T,L) 60,000 53-7/16 in. 21-1/8 in. 22-1/16 in. 175 lb 1357mm 536mm 560mm 79 kg SPECIFICATIONS FB4C 18 24 30 36 42 48 60 EVAPORATOR COIL Face Area(sq.ft) 2.23 2.97 4.45 5.93 Configuration Slope A FB4CNF TXV Metering Device (Copper and (Teflon—ring piston) EA52PT052 EA52PT057 EA52PT067 EA52PT070 EA52PT076 EA52PT080 Tin models Puron Refrigerant only) TXV FB4CNP (Aluminum Metering Device TXV TXV TXV TXV TXV TXV Puron Refrigerant models only) FILTER* 21-1/2—in 13—in 16-3/8—in 19-7/8—in (546 mm)X (330 mm) (417 mm) (505 mm) BLOWER ASSEMBLY Motor Type(ECM) Multi—tap ECM Motor HP 1/3 1/3 1/3 1/2 1/2 3/4 3/4 CFM 600 800 1000 1200 1400 1600 1750 *Filter must be field—supplied for FB4C units. 10 n 2140 Legacy" Line Heat Pump h �'r } with Puron® Refrigerant LJ y l 1-1/2 To 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES/BENEFITS „,,..... • ....,. Efficiency • 14 SEER/11.5- 11.7 EER/8.2 HSPF • Microtube Technology" refrigeration system • Indoor air quality accessories available Sound • Sound level as low as 69 dBA Aryan- • Sound levels as low as 68 dBA with accessory sound blanket Comfort • System supports Housewise"or standard thermostat controls Reliability • Puron®refrigerant-environmentally sound,won't deplete the ozone layer and low lifetime service cost. • Scroll compressor • Internal pressure relief valve • Internal thermal overload • High pressure switch • Loss of charge switch Puron • Filter drier �7 • Balanced refrigeration system for maximum reliability Durability Bryant heat pumps with Puron®refrigerant provide a collection of DuraGuard" protection package: features unmatched by any other family of equipment.The 214D . Solid,durable sheet metal construction has been designed utilizing Bryant's Puron refrigerant. The environmentally sound refrigerant allows consumers to make a • Dense wire coil guard responsible decision in the protection of the earth's ozone layer. • Baked-on powder paint NOTE: Ratings contained in this document are subject to Applications change at any time. Always refer to the AHRI directory • Long-line-up to 250 feet(76.20 m)total equivalent length,up (www.ahridirectory.org) for the most up-to-date ratings to 200 feet(60.96 m)condenser above evaporator,or up to 80 ft. information. (24.38 m)evaporator above condenser(See Longline Guide for more information.) • Low ambient(down to-20°F/-28.9°C)with accessory kit MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 2 1 4 D N A 0 3 6 0 0 0 0 Prod- Tier SEER Major Voltage Grille Cooling Capacity Open Open Open Minor uct Series Variations Series Family 2=HP 1= 4=14 SEER D=Puron N=208/23 A=Dense 1,000 Nominal Btuh 0=Not 0=Not 0=Not A= Legac- 0-1 Defined Defined Defined Original y P=208/230 Series RNC —3 E=460/3 uvi CERTIFIED C UL us Nixon. Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products,go to www.ahridirectory.org. STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Suction Line Accumulator X X X X X X X High Pressure Switch X X X X X X X Loss of Charge Switch X X X X X X X X=Standard 2 • DIMENSIONS - ENGLISH • MIT SERIES ELECTRICAL A B C D E F G K L M N P OPERATING ��NX SHP�' CHARACTERISTICS WEIGHT (bs) WEIGHT (bs) DIIiIENSIONS (L x W x H) 2140018 A X 0 0 0 23 1/8' 35 114' 3 3/4" 5/8' / 7/16' 18 1/16' 7 13/16' 2 13/16" 1/2' 11' 15 3/4' 12' 136 166 25 1/4• X 25 1/4' X 40" 2140024 A X 0 0 0 25 3/4" 35 1/4' 3 3/4' 5/8• 4 7/16• 21 1/4' 9 1/8' 2 13/16" 1/2• 12" 13 1/4• 13 1/2" 114 115 21 1/8" X 21 7/8• X 40" 2140030 A x 0 0 0 31 3/16" 31 13/16' 3 3/1' 3/4" 6 9/16• 24 11/16• 9 1/8' 2 15/16' 5/8' 15" 11" 16' 158 180 33 3/8' X 33 318• X 36 5/8• 2140036 B X 0 0 0 31 3/16' 28 7/16' 3 3/4• 3/4' 6 9/16' 24 11/16' 9 1/8' 2 15/16' 5/8' 15 3N• 14' 10 3/4' 110 201 33 3/8' X 33 3/8" X 33 1/4' 2140042 A X 0 0 0 31 3/16' 39 1/8" 3 7/8" 7/8' 6 9/16' 24 11/16' 9 1/8' 2 15/16' 518" 15 1/2' 13 1/2' 14• 201 235 33 3/8" X 33 303' X 43 1/2' 2140048 A X 0 0 0 31 3/16' 28 7/16' 3 7/8' 1/8' 6 9/16• 24 11/16• 9 1/8" 2 15/16' 5/8' 16 1/2' 11 1/2" 15• 197 232 33 3/8' X 33 3/8' X 33 1/4" 214D060 A X O0 0 0 31 3/16' 31 13/16' 3 7/8" 7/8' 6 9/16' 24 11/16' 9 1/8' 2 15/16' 5/8'_ 14 3/4' 15 3/4" 16 1/4' 212 248 33 3/8' X 33 3/8' X 36 S/8" 0 = NES A111 ' 0 = NO AL. AIR O FM AIR IN DISCHARGE G j AIR DISCHARGE _ __ i _—_ ry g o v 111111111111ft••..t .. ---.. 7� r i o �'.�m``1111 rt,,� , FIELD CONTROL AIR SUPPLY CONN. \ F B 07/8• HOLE \ AIA IN FIELD POWER SUPPLY CONN./8' HOLE WITH I N\ ��" N 01 1/8• KNOCKOUT o 1� 03/8' �/ o! °7G\'_� P } 00 � LIOUID LINE CONN.M\ _ 0 3 11/1: y�-��� - - E C 3 1/2" 0 / -4i 1 1/8• L 1 1/8"— 1 Y to. —_ K `AIR IN 00 VAPOR LINE CONN. I • F X S0. 03/8" TIEDOWN KNOCKOUTS 12) PLACES "8"14 IWid=D Y RE ROCIFTOPAPPLITA UNIT SIZE NOUN=PAD When installing,allow sufficient space for airflow clearance,wiring,refrigerant piping,and service.Allow 24 in.(609.6 mm) LUMP PAD APPl1CATI0N .A clearance to service end of unit and 48 in.(1219.2 mm)(above unit.For proper airflow,a 6—in.(152.4 mm)clearance on 1 DUDA= DttEM= side of unit and 12—in.(304.8 mm)on all remaining sides must be maintained.Maintain a distance of 24 in.(609.6 mm) 18 23 118. 17 3/4' between units or 18 in.(457.2 mm)if no overhang within 12 ft.(3.66 m)Position so water,snow,or ice from roof or eaves 24 25 314' 20 1/16' cannot fall directly on unit. 30,31,42,48,60 31 3/16' 23' NOTE:18"(457.2 mm)clearance option described above is approved for outdoor units with wire grille coil guard only.Units with louver panels require 24"(609.6 mm)between units. 35" 26 3/4' On rooftop applications,locate unit at least 6 in.(152.4 mm)above roof surface. s All-thread Refrigerant Lines Flue Piping upply Air Duct A/C Coil Drain Pan Return Air duct Condensate Drain 1 z Angle Air Filter 4/4:1 "AfYitircL FA4A Product FB4A Carrier Data FC4B Direct Expansion HEATING&COOLING Fan Coil Sizes 018 thru 070 Air Handling Technology At Its Finest Carrier's FA4A,FB4A,and FC4B direct expansion multipoise fan coils are designed to cover a wide range of air handling requirements.They _ are compact and ready to fit where needed — in the basement,crawl- ) space,attic,utility room,or closet. All units come with solid-state power board controls, 1-in. insulation with an R value of 4.2,super-quiet multispeed motors,and fully wettable coils.Units can accommodate factory-or field-installed heaters from 3 to 30 kw. The FA4A is the residential new construction(RNC)model in the line-up.It has an embossed galvanized steel casing,2-speed motor in 018 through 036 sizes and 3-speed motor in 042 through 060 sizes.The FA4A is equipped with an AccuRater®metering device. The FB4A is the standard of Carrier fan coils.It comes in a prepainted galvanized steel casing with foil-faced insulation and has a 3-speed motor in the full range of sizes 018 through 070.All FB4A units are equipped with an AccuRater metering device and are also shipped with a cleanable,permanent framed filter. The FC4B is the deluxe design in the fan coil group.It incorporates all the features found in the FB4A.In addition,it has a hard shut-off thermostatic expansion valve(TXV) metering device with internal check valve for reverse-flow bypass capability.The FC4B is available in sizes 024 through 070. Copyright 1996 Carrier Corporation Form FA4A-5PD Model number nomenclature F C 4 B N F 024 005 AEAA A Common Unit E Minor Engineering Change A Standard Unit A Standard Unit Electric Heater(kw) 003 015 005 020 008 024 009 030 010 Nominal Capacity(Btu) 018—18,000 042—42,000 024—24,000 048—48,000 030—30,000 060—60,000 036—36,000 070—60,000 B—Modular with 1 in.Super Thick Insulation C—Factory Installed Disconnects F—Sint le Piece Cabinet with 1 in.Super Thick Insulation N—208/230-1-60 A—Original Series B—Second Series 4—Multipoise A—RNC B—Standard C—Deluxe F—Fan Coil FM IOC UL •CERTIFICATION•LISTING C L •TESTING•INSPECTION ® aq agiO rationA"�, *a:vona" CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 4- Dimensions TOP VIEW UNIT CONNECTION SIZES 14 7/e"DIA KNOCKOUTS SUCTION.001&002-3/4"ID SWEAT, FOR LOW VOLTAGE 0"0130.005,&006 7/8"ID SWEAT CONTROL WIRING LIQUID. 3/eSWEAT CONDENSATE PAN CONNECTIONS 3/4"FPT 1 7/g" n NOTE:Series designation is the 14th position NV f1L of unit model number. X221he" 3/9 X103/13- ii"-0.- 1 15/16' 0.-11s/1fi' 7/e",1 3/32".2"DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING _ • B y. NOTE:Allow 21 In.from front y 1" - /e" • 15/18^4��__ for service. 2 I I OUTLET AIR I 1 DISCONNECT OR CIRCUIT ALTERNATE 1 b :, BREAKER LOCATION 7/9"DIA KNOCKOUT 3/4` 1 °I ° I ° FOR LOW VOLTAGE R BLOWER,CONTROL.&ELECTRIC CONTROL WIRING `ALTERNATE 7/9", OPTIONAL FILED HEATER ACCESS PANEL 13/32".2"DIA COPNVERTED RIGHT KNOCKOUTS FOR SIDE RETURN HIGH VOLTAGE OPENING COIL INLET AIR POWER WIRING ° ° COIL ACCESS PANEL LIQUID LINE LIQUID LINE I UNITS ONLV) OPPOSITE SIDE CONNECTION CONNECTION LIQUID LINE --------- --- CONNECTION 411/16" �' A II j ,� FITTING r ° E ° I° "I 1 FH R 25j8" PANEL 3 Vt e" 11/",y I ' I (MODULAR 4 ° SUCTION LINE I NOTE:Modular units I UNITS o / CONNECTION i- • 0 ° I I l will have a J ►� 1 two-piece I MAX. • • 10/d^ 11 1� I cabinet. it- 1077/16- .� O 11 • 9 11/2^ o 0 ° o he"y1 11/2"y1 1�1 1 - �O _ . 63/16" ��_ • QQ 1 �o--.--.-_.--._-.° SUCTION LINE �T` t 13 OPENING I } 1/4" 19 /16" I OPENING FILTER ACCESS CONNECTION 2 1/2" 1"+I Fes--D PANEL ACCESS PANEL CONFIG FOR SLOPE COIL DETAILS SLOPE COILS RIGHT SIDE VIEW INLET AIR CONNECTION LOCATIONS DOWNFLOW OR HORIZ FRONT VIEW SHOWN WITH"A"COIL SHOWN FOR UPFLOW RIGHT APPLICATIONS I INLET AIR OR HORIZ LEFT APPLICATIONS AND"A"COILS A95535 DETAILS CONNECTION LOCATIONS DOWNFLOW APPLICATIONS FOR UPFLOW OR HORIZ APPLICATIONS UNIT COIL A B C D E Ht J SIZE` TYPE In. mm In. mm In. mm In. mm In. mm In. mm In. mm 018,024 Slope 42-11/16 1084.3 14-5/16 363.5 12-7/16 316.0 12-5/16 312.7 10-7/16 265.1 - - 12.0 304.8 030 Slope 47-11/16 1211.5 17-5/8 447.5 15-3/4 400.1 15-5/8 396.9 15-3/8 390.5 - - 17.0 431.8 036 Slope 49-5/8 1260.5 17-5/8 447.5 15-3/4 400.1 15-5/8 396.9 15-3/8 390.5 - - 17.0 431.8 033,042 ' Slope 53-7/16 1357.3 21-1/8 536.5 19-1/4 489.0 19-1/8 485.8 19-3/16 487.0 28-5/16 719.1 19.0 482.6 048 A 49-5/8 1260.5 21-1/8 536.5 19-1/4 489.0 19-1/8 485.8 15-11/16 398.3 24-1/2 622.3 - - 038,060 A 53-7/16 1357.3 21-1/8 536.5 19-1/4 489.0 19-1/8 485.8 19-1/2 495.3 28-5/16 719.1 - - 054,070 A 59-3/16 1503.4 24-11/16 627.0 22-3/4 577.9 22-11/16 576.2 25-1/4 641.5 34-1/16 865.2 - - Descriptions and dimensions apply to all versions(FA4A,FB4A,and FC4B),unless otherwise specified. t Applicable for modular units only. I 7 Dimensions continued SLOPE COIL AIRFLOW AIRFLOW 23/'16P " 1 TV /gyp (2 PLACES)' 1 TVP (4 PLACES)' L1- I _ __, i PRIMARY DRAIN LJ NP (2 PLACES)' SECONDARY DRAIN SECONDARY DRAIN 1,y1e. 1%ey� Via.• PRIMARY DRAIN PRIMARY DRAIN TYP•+{SECONDARY DRAINNP1 E SECONDARY DRAINj__ ' [1111E / 1i-I 1 + 1-4 1 ryP PRIMARY DRAIN I �' 2 PLC9)l I� + 7111 O 1}i r j{- - .s Z,," 21/ Lt�'TVP' }`I— tie I-2 e 1 J NP 16/, NP•� TVP• III—_' I 1 4z NP (4 PUCESY 5"� (2 PLACES). 1TYP: 2" 1"/ie 4„ .f a^ 1 /,6" —� 2 57 �—F NP NP• HORIZ LEFT UPFLOW DOWNFLOW HORIZ RIGHT (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) (FIELD CONVERTED) AIRFLOW AIRFLOW e 2°/ie" •HORIZONTAL MOUNT LOCATIONS-DIMPLES PROVIDED IN TOP / NP 1r NP PANEL,AND BACK OF CABINET.IN CABINET BOTTOM,HOLES PROVIDED 'I` (4 PLACES)' # \ (2 PLACES)' .1361N.DIA.HORIZONTAL HANGING HARDWARE TO BE FIELD ,��� 1 ( SUPPLIED. _ SECONDARY DRAIN 434 O 0 r SECONDARY DRAIN PRIMARY DRAIN 1_1" G TYP F PRIMARY DRAIN (2 PLACES)' 3 !A°,"- SECONDARY a PRIMARY DRAIN 1'%P 7 r - IIr TYP' SECONDARY DRAIN TVP' N. ji 1 SECONDARY DRAIN • O O11 e.� PRIMARY DRAIN r t— O ED IN CABIN _ � — 1 0 —IIwEf�. �_ --- T1 1'/i 5„r1 2,�JI 1-2 It, L3" • ,• �� 1 i3.-� 5,/e�'- 1'/a" '-J Lc,1'/i ,1. TYP Ty•NP'(2 PLACES)' TYP N'p• ]'/e f• + 3'n (4 PLACES)' T'e 1)� TVP' y 43/a TVP' HORIZ LEFT UPFLOW DOWNFLOW HORIZ RIGHT (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) (FIELD CONVERTED) A95531 A—COIL UNIT COIL F G SIZE' TYPE In. mm In. mm 018,024 Slope 18-1/8 460.4 18-5/8 473.1 030 Slope 23-1/8 587.4 23-5/8 600.0 036 Slope 23-1/8 587.4 23-5/8 600.0 033,042 Slope 26-15/16 684.2 27-1/2 698.5 048 A 23-7/16 593.3 23-1/8 587.4 038,060 A 27-1/4 692.2 26-1516 684.2 054,070 A 32-15/16 836.6 32-5/8 828.7 Descriptions and dimensions apply to all versions(FA4A,FB4A,and FC4B),unless otherwise specified. cn Physical data MODEL FA4A 018 024 030 036 — 042 048 — 060 — - - FB4A 018 024 030 036 _ — 042 048 — 060 — 070 FC4B* — 024 030 036 033 042 048 038 060 054 070 SHIPPING WT(Lb) 94 98 126 128 147 147 154 168 168 199 199 REFRIGERANT METERING DEVICE Bypass AccuRater(FA4A,FB4A);TXV Factory Installed on FC4B PISTON SIZE 52 65 73 80 — 84 88 — 101 — 101 TXV SIZE t — 2 ton 2-1/2 ton 3 ton 2-1/2 ton _ 3 ton 4 ton 3 ton 5 ton 4 ton 5 ton COIL Rows and Fins Per In. 2 and 14.5 3 and 14.5 3 and 14.5 3 and 14.5_3 and 14.5 3 and 14.5 3 and 14.5 3 and 14.5 3 and 14.5 3 and 14.5 3 and 14.5 Face Area(Sq Ft) 2.23 2.23 2.97 2.97 3.46 3.46 4.45 5.93 5.93 7.42 7.42 Configuration Slope Slope Slope Slope Slope Slope A A A A A FAN Air Discharge CFM(Nominal) 650 850 1100 1300 1100 1500 1700 1300 2000 1700 2000 Motor Hp(PSC) 1/5** s 1/4 1/3** 1/3 1/3 1/2 3/4 1/3 3/4 1/2 3/4 FILTER* 21-1/2 x 13 21-1/2 x 16-3/8 21-1/2 x 19-7/8 21-1/2 x 23-5/16 Fan coil units with hard shut-off TXV may require compressdor hard start components.Refer to outdoor unit specifications. t FC4B factory-installed TXV is hard shut-off,bypass flow-type for heat pump application. t Filter must be field supplied for FA4A units.(See Accessory Kits.) FA4A018 fan coil has a 1/10 Hp motor FA4A030 fan coil has a 1/4 Hp motor NOTE:Descriptions and dimensions apply to all versions(FA4A,FB4A,FC4B,etc.),unless otherwise specified. 6 °id "t /l Product 38CKB(N) (60 Hz) (arrier Data Air Conditioner HEATING&COOLING 38CKB Sizes 018 thru 060 38CKN Sizes 024 thru 048 • Model 38CKB(N)Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable summer cooling performance. Built into these units are the features most desired by homeowners today, including SEER ratings of up to 11.5 when used with components designated by manufacturer.The _ 1 4k 38CKN is specifically constructed for manufactured housing,and is listed with RADCO.All models are listed with UL,c-UL,ARI,and CEC. FEATURES/BENEFITS I I Electrical Range—All units are offered in 208-230v single phase. Three-phase units are available from 030 through 060 sizes in 208/230v and from 036 through 060 sizes in 460v. Wide Range of Sizes—The 38CKB I is available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications.The 38CKN is available in 5 nominal sizes from 024 through 048 to meet the needs of the V anufacturedhousinmarket.eather Armor II Cabinet—The steel is protected with a heavy coating z � commonly called "galvanizing,"and treated with a layer of zinc phosphate. A modified polyester powder coating is then applied and baked on,providing each unit with a hard,smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting,rust-resistant, quality appearance. Totally Enclosed Fan Motor— Means greater reliability under rain conditions and dependable performance Copyright 1996 Carrier Corporation Form 38CKB-2PD for many years.Permanent-split- evaporator coils and blower packages refrigerant pressures. capacitor-type motors provide more to provide quiet,dependable comfort. Easy Serviceability—One access economical operation. Unit can be installed on a roof or at panel provides access to electrical Unit Design—Copper tube,enhanced ground level. control box.Removal of top allows sine wave aluminum fin coil is External Service Valves—Both access to fan motor and coil. designed for optimum heat transfer. service valves are brass,front seating Vertical air discharge carries sound and type.The 38CKB has sweat field YP Compressor Protection—Each away connections.The 38CKN has hot condenser air upand from compressor is protected with internal adjacent patio areas and foliage.Heat mechanical field connections.Valves temperature-and current-sensitive pump style drain pan allows for easy are externally located so refrigerant overloads. removal of water,dirt and leaves. tube connections can be made quickly Warranty—Standard 1 year on parts, Application Versatility—The unit and easily.Each valve has a service with an additional 4 years on can be combined with a wide variety of port for ease of checking operating compressor. ``Br Cor.ora Garq PlanEA LI . 43 ® ® L C ® L 'so,EREO 's pool #I'9" CERTIFICATION APPLIES ONLY WHEN CERTIFICATION OF THE COMPLETE SYSTEM IS LISTED WITH ARI. MANUFACTURING SITE. Model number nomenclature 38CKB(N) 018 3 0 1 Electric Air Conditioner Packaging Nominal Capacity Series 018—18,000 Btuh 042—42,000 Btuh Electrical 024—24,000 Btuh 048—48,000 Btuh 3—208/230-1 030—30,000 Btuh 060—60,000 Btuh 5—208/230-3 036—36,000 Btuh 6—460-3 The data in this publication is displayed for all series,however,every series may not be available from manufacturer. Physical data 03030,50/ 036-30t0,60/ 042-30,5W 048-30,50,60/ 06030,50,60/ UNIT SIZE 018-31/32 024-30/31/32 31,51/32 31/32,52,62/33 31,51,61 31,51,61 31,51,61 OPERATING WT(LB) COMPRESSOR Tec Recip/ Copeland Copeland Millennium ScrolV Millennium Millennium Millennium Manufacturer&Type Bristol Recip Recip/ Recip/ Copeland Recip/ ScrolVCopeland ScrolVCopeland ScrolVCopeland Tec Recip/ Tec Recip/ Teo Recip/ Recip Scroll Scroll Bristol Recip Bristol Recip Bristol Recip REFRIGERANT R22 Control AccuRater®(Bypass Type) Charge(LB)CO 15 ft 3.44/4.25 I 3.76/3.82/4.50 I 4.19/4.46/4.75 I 4.63/5.00/4.78/5.25 I 5.00/5.13 I 6.63/6.38 I 9.89/8.46 COND FAN Propeller Type,Direct Drive Air Discharge Vertical Air Qty(CFM) 1400 I 1550 I 2000 I 2500 I 3400 COND COIL Copper Tube,Aluminum Plate Fin Face Area(SQ FT) 5.6/6.18 I 6.3/6.9/6.8 I 6.9/7.4/8.28 I 9.0/9.0/8.2/9.0 I 10.7 I 14.8 I 19.8/16.1 VALVE CONNECT.(IN.ID) Sweat Vapor 5/8 I 3/4 I 7/8 Liquid 3/8 REFRIG TUBES*(IN.OD) 3/4 5/8 7/8 1-1/8 Vapor I I I Liquid 3/8 NOTE:See unit Installation Instructions for proper installation. *Tube sizes are for runs up to 50 ft.For tubing set over 50 ft,consult Long-Line Application Guideline. 2 Certified drawing — 38CKB CO_ ELECTRICAL A B CDEF GHJK L M N p SHIPPING UNIT ¢ CHARACTERISTICS WEIGHT w In. In. In. In. In. In. In. In. In. In. In. In. In. In. Lb. 38CKB018 1 X 0 0 0 18 2115/16 33/16 5/8 3 15 165/16 173/4 103/16 16 1/2 174/4 77/8 8% 9% 118 38CKB018 2 X 0 0 0 18 23 15/16 33/16 5/8 3 15 16 5/16 17 3/4 10 3/16 161/8 173/4 7 7/8 8% 91/2 120 38CKB024 0 X 0 0 0 18 2315/16 3 /16 5/8 3 _ 15 16 5/16 173/4 10 3A6 16 1/2 173'4 7 7/8 8% 91/2 120 38CKB024 1 X 0 0 0 18 2515/16 3 356 5/8 3 15 16 5/16 173/4 10 3/16 16 1/2 173/4 7 7/8 8% 10 1/8 122 38CKB024 2 X 0 0 0 18 2515/16 3 3'16 5/8 3 15 16 5/16 173/4 103/16 16 1/8 173/4 7 7/8 83/8 10 1/8 122 38CKB030 0 X 0 X 0 221 21 15/16 3 3/16 3/4 311/16 18 1/8 194/4 22 1/4 14% 19 9/i s 22 1A6 10 4 10 1/4 104/4 129 38CKB030 1 X 0 X 0 221/2 21 15/16 3 3/16 3/4 311/16 18 1/8 194'4 22 1/4 14 3/8 19 9/16 22 1/16 103/8 103/4 103/4 127 38CKB030 2 X 0 0 0 221/2 2315/16 3 3/16 3/4 3 11A 6 18/ 193/4 22 1/4 14% 19 9/16 22 1/16 10 4 10 3/4 10 7/8 138 38CKB036 0 X 0 X X 22 1/2 25 15/16 3 3/16 4/4 3 11A 6_18 1/13 193/4 22 1/4 14 3/8 19 9/16 22 1/16 10 1/4 9 1/2 , 111/4 134 38CKB036 1 X 0 0 0 221/2 2515/16 3 3/16 3/4 311/16 18 1/8 193/4 22 1/4 14 3/8 19 9/16 221/16 10 1/4 91/2 11 1/4 143 38CKB036 2 X 0 X X 22 1/2 23 15/16 3 3/16 3/4 3 11/16 18 1/8 194'4 221/4 14% 19 9/16 22 1/16 10% 103/4 10 7/8 138 38CKB036 3 X 0 0 0 22 1/2 2515/16 3 3/16 3/4 311/16 18 1/8 193/4 22 1/4 14 3/8 19 9/16 221/16 10% 103/4 11 1/4 143 38CKB042 0 X 0 X X 221/2 2915/16 31/4 7/8 3 11A 6 181/2 1913/16 221/4 144 199/16 221/16 101/4 91/2 11 5/8 143 38CKB042 1 X 0 X X 22 1/2 29 15/16 3 1/4 7/8 3 11/16 18 1/8 19 13/16 22 1/4 143/8 19 9/16 22 1/16 10% 104'4 11 1/8 147 38CKB048 0 X 0 X X 30 2715/16 31/4 7/8 61/2 231/2 271/4 294/4 20 271/16 299/16 15 13 141/2 197 38CKB048 1 X 0 X X 30 2715/16 31/4 7/8 61/2 231/2 271/4 293/4 20 271/16 299/16 15 13 141/2 203 38CKB060 0 X 0 X X 30 3515/16 31/4 7/8 6 1/2 23 1/2 271/4 29 3/4 20 271/16 29 9/16 15 1/2 14 15 1/2 238 38CKB060 1 X 0 X X 30 2915/16 31/4 7/8 6 1/2 23 1/2 271/4 29 3/4 20 27 1/16 29 9/16 15 1/2 14 15 223 o 0 X=YES 0 0" o O=NO N .— N M 03 O co O o co 0 C0 N N N W A Sa AIR DISCHARGE M AIR IN AIRAIDISCHARGE \'� - FIELD POWER SUPPLY CONN 1 ."—=======------==== 7/8 IN.DIA HOLE WITH ° ® 1 1/8 IN.DIA KNOCKOUT 7AND 1 3/BIN.DIA KNOCKOUT J 11.11111 I.I rY11/ s ���I�1K AIR IN FIELD CONTROL SUPPLY AIR IN - 1 ..�«��``� 111 . 'lljl" L CONN /BIN.DIA HOLE 3/BIN.DIA ',1 , ,� JJ �"' B 111111111 TIEDOWN l 'Kt+- `� �I/ W qil 1 `{`}'.�J� KNOCKOUTS ��, �� Ia��1__�y. 4 1 3/81N.DIALIQUID (2)PLACES , �`` �. `• — 1 LINE CONN ���!�►�. Ii1r111`i. Oo 1 0 I I Iia'1�11�f� Li AIR DISCHARGE I _ L� '�J±7/e% C E IFS_ AIR IN I F—0-1 D DIA VAPOR LINE CONN 1 1/4" ' G H NOTES: 1. Allow 30 In.clearance to service side of unit,48 In.above unit,6 In.on one side, 12 In. MINIMUM on remaining side,and 24 In.between units for proper airflow. UNIT SIZE MOUNTING PAD 2. Minimum outdoor operating ambient in cooling mode is DIMENSIONS(In.) 55°F,max.125°F. 18,24 18 x 18 3. Series designation is the 13th position of the unit x 22 30,36,42 22 1/z 1/z model number. 4. Center of gravity O. 48,60 30 x 30 A96037 3