Loading...
Report (2) ffiSoZOI -• 000 7c0,37) Si&v / i' GLFireworX Fire & Life Safety Security Accessories RECEIVED APR 1 2015 CITY OF TIGARD BUILDING DIVISION Overview Standard Features GE Electromagnetic Door Holders are ruggedly constructed and • Surface mount,semi-flush, flush,and floor mounted models attractively designed.The housings are baked with a durable poly • Chrome or brass finishes blend In with other door hardware ester undercoating and are available in either a chrome or brass finish. • Low power consumption The floor or wall section houses the electromagnet while the • AC/DC models contact plate attaches to the door.The contact plate has a shock • Completely silent operation25 Lbf(111N)nominal holding force absorbing nylon(swivel)ball which allows the plate to adjust to any door angle.Floor units are available in single-door or double-door • Adjustable,swivel contact plate (back to back)versions.Wall units are available in flush or surface mounted versions.GE door holders should be installed wherever doors may be effectively used to confine smoke and fire,or where the release of a self-closing door from a remote location is desirable for other reasons.Always consult your local Authority Having Juris- diction with any questions regarding a specific application.Fail-safe operation is an inherent feature of GE Security door holder-releases. If power fails,doors are released automatically but may be opened or closed manually at any time.All units are free of moving parts, are self-contained and require no maintenance.These door holder- releases have a holding force of approximately 15 to 25 Lbf(66 to 111N).Ttie device holds a door open while energized. When de-energized by a relay controlled by the fire alarm system or other switch,the door is released to a closed position,checking the spread of smoke and flames.Electromagnetic door holders should be used and installed in accordance with local Building Codes and Standards. Electromagnetic Fire Door Holdersry.4 .. b 7 DH Series f ^� # - ' a h. • o:. . _ V ' i* Data Sheet FX85001-0603 Issue 1 — Not to be used for installation purposes.Page 1 of 4 Surface Mount Back Box Dimensions Door Magnet T 0 Y.Iw 2Y® O. 11]m 11)om Y.m Q '. fi �Io I _ L2 0 c wi III 5.2 am ].1 om --► ►< ].0 1.1.. 93.. 2.Y® 2.wl Extension Rod Applications Catch Plate Assembly and Accessories DEIN W 1\ 11) N. A DH-ERI 7•l� CIO ) C)LI rE 2.5.w DH-ER3 r C— r Data Sheet FX85001-0603 Issue 1 Not to be used for installation purposes.Page 2 of 4 • Extension Rod Applications Catch Plate Assembly and Accessories Voltage Reference /O O1 C—Common L—Low H—High (C+L)Low Voltage t I C L H Low Voltage ®®® I I t C L H (C+H)High M LM M Voltage ( ) ( ) ( ) High Voltage Low Voltage ,J1 I C L H C L IH High Voltage •/ 4 1 C L H C IL H Performance Data t. Model Voltage DC/mA AC/mA Terminals Coil lbs kg.(Nominal) DHX*-1224 12V 30 30 C&L Single 35 15.9 24V 15 15 C&H Single 35 15.9 DHX*-24120 24V 15 15 C&L Single 35 15.9 120V — 15 C&H Single 35 15.9 DHFMt-1224 12V 60 60 C&L Double 35 15.9 24V 60 60 C&H Double 35 15.9 DHFMt-24120 24V 30 30 C&L Double 35 15.9 120V — 30 C&H Double 35 15.9 *For all models,"X~represents either F(Flush Mount),FM(Floor Mount single-coil),R(Recessed),or S(Surface Mount). t For Floor Mount,double coil models. NOTE:Voltage supplied by a UL listed control panel Data Sheet FX85001-0603 Issue 1 Not to be used for installation purposes.Page 3 of 4 Security u.5. Ordering Information T 888-GESECURITY F 503-691-7566 Model Description Case Qty Canada Wall Mount T 519 376 2430 DHR-1224C 12 or 24 V DC/V AC,recess-mount,chrome,with 3"Extension Rod 20/case F 519 376 7258 DHR-24120C 24 V DC/V AC 120V AC,recess-mount,chrome,with 3"Extension Rod 20/case Asia DHF-1224C 12 or 24 V DC/V AC,semi-flush-mount,chrome 20/case T 852 2907 8108 DHF-1224B 12 or 24 V DC/V AC,semi-flush-mount,brass 20/case F 852 2142 5063 DHF-24120C 24 V DC/V AC 120V AC,recess-mount,chrome 20/case Latin America DHF-2410B 24 V DC/V AC 120V AC,semi-flush-mount,brass _ 20/case T 305 593 4301 DHS-1224C 12 or 24V DC/V AC,surface-mount,chrome 20/case F 305 593 4300 DHS-1224B 12 or 24V DC/V AC,surface-mount,brass 20/case www.gesecurity.com/fireworx DHS-24120C 24V DC/V AC 120V AC,surface-mount,chrome 20/case ©2009 General Electric Company DHS-24120B 24V DC/V AC 120V AC,surface-mount,brass 20/case All Rights Reserved Floor Mount DHFM1-1224 Single coil,12 or 24VDCNAC,floor-mount,brushed steel 6/case DHFM1-24120 Single coil,24VDC/VAC 120VAC,floor-mount,brushed steel 6/case DHFM2-1224 Double coil,12 or 24VDC/VAC,floor-mount,brushed steel 6/case DHFM2-24120 Double coil,24VDCNAC 120VAC,floor-mount,brushed steel 6/case Extension Rods DHFM1-1224 Single coil,12 or 24VDCNAC floor-mount,brushed steel DH-ER1C 1"chrome DH-ER1B 1"brass DH-ER3C 3"chrome DH-ER3B 3"brass Accessories DHW Extension rod wrenches DH-BP Back Plate(chrome or brass) DH-ARMC Replacement armature,chrome DH-ARMB Replacement armature,brass imagination at work Data Sheet FX85001-0603 Issue 1 Not to be used for installation purposes.Page 4 of 4 c, GENTEX CORPORATION Commander4 Series Selectable GCS/GCC Candela Evacuation Signals 24VDC Applications SERIES The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The GCS/GCC offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz and W mechanical tone. All tones are easy for the professional to change in the field — by using switches. The models are shipped from the factory in the temporal three alarm mode. t : r The GC Series has a very minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. 111111) The Commander4 Series comes standard with the 4" mounting plate which incorporates the popular Super-Slide®feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander4 also features the patented Checkmate®- Instant Voltage Product Listings Verification feature which allows the installer to check the voltage drop draw SIGNALING without removing the signal. The GC Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use APPROVED J with fire protective systems and are warranted for three years from the date of LISTED I— �1 purchase. •ANSWL464and ANSWL1971 Listed •FM Approved •CSFM: 7135-0569:122(GCC) Standard Features 7125-0569:123(GCS) • Nominal voltage 24VDC •MEA: 285-91-E • Tamperproof field selectable candela options of 15, 30, 75, 95,115 & 150 Patents • Super-Slide®Bracket- Ease of Supervision Testing •7,375,617 May 20,2008 • Checkmate°- Instant Voltage Verification • Unit Dimensions:6" (15.24 cm) x 2.6"(6.604 cm) Product Compliance • Synchronize strobe and/or horn with Gentex AVSM Control Module •NFPA 72 •Americans with Disabilities Act(ADA) • Prewire entire system, install mounting bracket, then install signals •IBC/IFCARC • Documented lower installation and operating costs •City&State ordinances/Laws/Regulations • Input Terminals 12 to 18 AWG •Quality Management System is certified to: • Switch Selection for High or Low dBA ISO 9001:2008 • Switch Selection for 2400Hz or Mechanical Tone NEM • Switch Selection for Continuous or Temporal 3 �rMEMBER • Tamperproof re-entrant grill ASSEMBLED IN • Surface mount with the GCSB (Gentex Ceiling Surface Mount Box) THE USA • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white GCS Series 24 Volt Ceiling Mount Selectable Strobe Model Part Nominal Candela Number Number Voltage GCS24CR 904-1213-002 24VDC 15,30, 75, 95, 115, 150 GCS24CW 904-1215-002 24VDC 15,30, 75, 95, 115, 150 GCS24PCR 904-1214-002 24VDC 15,30, 75, 95, 115, 150 GCS24PCW 904-1216-002 24VDC 15,30, 75, 95, 115, 150 GCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Part Nominal Candela Reverberant dBA @ In Anechoic Room Number Number Voltage 10ft.per ANSI/UL 464 dBA @ 10ft. GCC24CR 904-1209-002 24VDC 15,30, 75, 95, 115, 150 81-86 90 GCC24PCR 904-1210-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24CW 904-1211-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCW 904-1212-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 Model Designations: C=Ceiling Mount R= Red Faceplate W=White Faceplate All units are available in plain (no lettering). Plain units are non-returnable. GC24 Product Strobe Current Ratings (mA) Candela 15cd 30cd 75cd 95cd 115cd 150cd 24VDC 72mA 101 mA 167mA 200mA 214mA 286mA 24VDC (16-33 Volts) UL Max' 120mA 120mA 200mA 220mA 290mA 321 mA GCC24 Product Horn Decibel and Current Ratings (mA) Minimum dBA @ 10ft. Minimum dBA @ 10ft. Regulated 24VDC Horn Mode per ANSI/UL 464 per ANSI/UL 464 Max.Operating (HIGH) (LOW) @ High Setting(mA) Temp 3 2400Hz 83 75 23 Temp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 NOTES: • Operating temperature:32°to 120°F(0°to 49°C). The GC Series is not listed for outdoor use. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Mounting Super-Slide® i, 3.SNAP COVER OVER ASSEMBLY A 2. INSERT LOCKING SCREW v \ ; .101-417.- %* ��. I 0■11h. Al RI / . 1.0 r°'.e . eall,'VI - \ ' 'ZZ4 Cfi) --; / \ ',ir. ,,,,Sil. cff‘3 .. ewe ,,, 1.SLIDE ONTO BRACKET Checkmate® Instant Voltage Verification Switch Locations • C''1 I) 1 DO NOTrl!.M ` 12345 1 o o it- / 0 , ‘7/: \c—i _ / IF /]\, 1 .1 I _ g 0 O 1)/'' �1 15 Q 1O MI 'moi u I, i � M b — c�� -. IfE— 0 1 cpr C ::-_: czji) . 1.A1 The access holes are provided in the back of the terminal block 0 to allow the voltage to be measured directly without removing the Switch positions 1 and 2 in the down position to select device.Typically this would be done at the end of the line to isolated horn and strobe power inputs. Switch 3 selects confirm design criteria.Most measurements will be taken using between temporal or non temporal tone. Up is temporal. the S+and S locations although access is provided to other Switch 4 selects between mechanical or high frequency locations. NOTICE:CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. tone. Up is mechanical. Switch 5 selects between high or low dBA. Up is high dBA. Conventional GC Series Wiring Diagrams UL Listed UL Listed COntr01 Signal Signal Control Signal Signal Panel Sc S+ S- H+ H- S+ S+ S- H+ H- Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised V V V V V V SupervisedS S S ® 0 O ► a 0 0 Signal Circuit 11111 1111" Signal Circuit - mug END LINE NE SST ON + 11 \ O END OF LINE RESISTOR o 1 RE END SISTOF LINORE \ 0 NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by - Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC.The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 29 pounds per carton Important Notice: 551-0051-06 G E N T E X These materials have been prepared by Gentex Corporation Gentee)for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,stale and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding Fire Protection Products Group•www.gentex.com mterpretartlon of laws,regulations and rules and the application of such laws,regulations and rules to 9 particular fact patterns.Each person's activities can differently affect the obligations that exist under 10985 Chicago Drive •Zeeland, Michigan 49464 applicable laws,regulations or rules.Therefore,these materials shouldbe used only for informational purposes and Should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. GENTEX CORPORATION Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications The Commander3 Series is a low profile strobe and horn/strobe combination SERIES that offers dependable audible and visual alarms and the absolute lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options ofy # 'i 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field i' °�`"'Ir ,,. -' , i selectable candela options of 15, 30, 60, and 75 candela. R' The Commander3 Series horn offers a continuous or synchable temporal three E R in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy :I!l111i for the professional to change in the field by the use of switches. The GE3 Series has a minimal operating current and has a minimum flash rate — of 1 Hz regardless of input voltage. Product Listings The Commander3 Series is shipped with a standard 4" metal mounting plate SIGNALING which incorporates the popular Super-Slide®feature that allows the installer to =;5`` easily test for supervision.The product also features a locking mechanism CI)which secures the product to the bracket without any screws showing. • The Commander3 also features the patented Checkmate°- Instant Voltage LISTED 1��v 1 Verification feature which allows the installer to check the voltage drop draw • ANSI/UL 464&ANSI/UL 1971 Listed and match it to the blueprint. • CSFM: 7135-0569:122(GEC3-24& The GE3 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use GEH-24) with fire protective systems and are warranted for three years from date of 7125-0569:123(GES3-24) purchase. 7125-0569:129(GES3-12) 7135-0569:130(GEC3-12& Standard Features GEH-12) • MEA: 285-91-E(GEC3-24&GES3-24) • Nominal voltage 12VDC and 24VDC 580-06-E(GEC3-12&GES3-12) • 24VDC units have field selectable candela options of 15, 30, 60, 75 & 110 • 12VDC units have field selectable candela options of 15, 30, 60 & 75 Patents • GEH horn is available in 12VDC or 24VDC • 7,375,617 May 20, 2008 • Unit Dimensions: 5"(12.7 cm) high x 4.5"(11.43 cm) wide x 2.5"(6.35 cm) deep Product Compliance • Super-Slide® Bracket- Ease of Supervision Testing • NFPA 72 • Checkmate®- Instant Voltage Verification • Americans with Disabilities Act(ADA) • Synchronize strobe and/or horn with Gentex AVSM Control Module • IBC/IFC/IRC • Prewire entire system, install mounting bracket, then install signals • Quality Management System is certified • Documented lower installation and operating costs to:ISO 9001:2008 • Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA ISM • Switch for chime, whoop, mechanical and 2400Hz tone MEMBER • Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) ASSEMBLED IN • Surface mount with the GSB (Gentex Surface Mount Box) THE USA • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white ' GEH 12VDC or 24VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage 10ft.,Revrberant dBA at In Anechoic Room per ANSI/UL 464 dBA at 10ft. GEH12-R 904-1239-002 12VDC 62-82 100 GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 GEH24-W 904-1207-002 24VDC 62-82 100 GES3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Strobe i Model Number Part Number Nominal Voltage Candela (ANSI/UL 1971) GES3-12WR 904-1235-002 12 VDC 15, 30, 60, 75 GES3-12WW 904-1237-002 12 VDC 15, 30, 60, 75 GES3-24WR 904-1321-002 24 VDC 15, 30, 60, 75, 110 GES3-24WW 904-1319-002 24 VDC 15, 30, 60, 75, 110 GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA at In Anechoic Room (ANSI/UL 1971) 10ft., per ANSI/UL 464 dBA at 10ft. GEC3-12WR 904-1231-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-24WR 904-1317-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GEC3-24WW 904-1315-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GE3 Product Strobe Current Ratings (mA) Model Designations: 12 VDC (8-17.5 Volts) 24 VDC (16-33 Volts) W =Wall mount Candela 12VDC UL Max' 24VDC UL Max' R = Red Faceplate W =White Faceplate 15cd 106mA 92mA 30mA 42mA All units are available in plain (no lettering). 30cd 131 mA 141 mA 35mA 58mA Plain units are non-returnable. 60cd 186mA 260mA 66mA 97mA 75cd 237mA 312mA 80mA 116mA ALERT bezel available for order 110cd 103mA 161mA AGENT bezel available for order GE3-12 Product Horn Current Ratings GE3-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 12VDC Minimum SPL Minimum SPL Regulated 24VDC Horn Mode at 10ft.,per at 10ft.,per Max.Operating 0 Horn Mode at loft.,per at 10ft.,per Max.Operating ANSVUL 464 ANSVUL 464 High Setting(mA) ANSVUL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) (HIGH) (LOW) Temp 3 2400Hz 76 dBA 69'dBA 29mA Temp 3 2400Hz 78 dBA 71'dBA 28mA Temp 3 Mechanical 75 dBA 68'dBA 26mA Temp 3 Mechanical 76 dBA 70'dBA 25mA Temp 3 Chime 62'dBA 60'dBA 13mA Temp 3 Chime 70'dBA 66*dBA 15mA Continuous 2400Hz 79 dBA 74'dBA 29mA Continuous 2400Hz 81 dBA 74'dBA 28mA Continuous Mechanical 78 dBA 72'dBA 26mA Continuous Mechanical 80 dBA 72*dBA 25mA Continuous Chime 63*dBA 61'dBA 13mA Continuous Chime 70"dBA 66*dBA 15mA Whoop 78 dBA 71'dBA 55mA Whoop 82 dBA 69'dBA 56mA NOTES: • Operating temperature:32°to 120°F(0°to 49°C). The GEC3 and GES3 Series is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. 12VDC models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode . fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). 1 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 t • Mechanical Temporal 3 ON ON ON r=[—■ 10.01= Mechanical-Continuous OFF ON ON — 2400Hz-Temporal 3 ON OFF ON 1=[t\)MI ■■ —M 2400Hz-Continuous OFF OFF ON (=C will ■■ Chime-Temporal 3 ON ON OFF ■ ■■ A- 17E-PJD Chime-Continuous OFF ON OFF �' Whoop ON OFF OFF CZE(xi■ ■■ _M oIE•F Whoop OFF OFF OFF CE ail MN 1=3wow • l NOTE: ® 1 -I • Switch Positions 1 and 2 in the OFF position to m1 select isolated horn and strobe power inputs • Switch Position 6 ON = HIGH dBA ul11-1 • Switch Position 6 OFF=LOW dBA kly rz--- )i. , N Gentex Super-Slide® Gentex Checkmate® Instant Mounting Bracket k Voltage Verification Allows the installer to pre-wire It is often necessary to confirm the the system, test for systemvoltage drop along a line of devices.The supervision, remove the signal access holes are provided in the back of head until occupancy, switch 'i the terminal block to allow the voltage to 1 l out Gentex signals without be measured directly without removing the changing mounting bracketsdevice.Typically this would be done at the and has locking edge connector I k I . ifi• end of the line to confirm design criteria. for snap-in-place installation. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. _ J NOTE:Care should be taken to not short x0 ' the test probes. / Candela selection slider - _ M ► switch. Depress center-•y'"' I .-----ON/00 r... and slide switch to desire brightness level. \� (?.71,r�� si _ I I II Break off pin and insert ; ,�I_ I '" ij ■1� I1 into hole at the bottom of ri Hul the selector to lock <_- ® IrI MODELI �i#.1tit candela setting. Signal 1 IiiE1ECi0N 11I' _E� ��g g1MARKER ��� . 11141 must be removed from 1 �"'' I 1 1 'i 1 i i��f�I bracket and pin pushed • l { t•I i :forward from backside out i------;:--'....'- candela. IM',, • of hole to change 1 I��.�-' � candela. ��� A . f• To remove bezel, grip both sides of bezel and pull in a downward and outward motion. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel Signal Signal Signal Signal S+ s+ S- H+ H- S+ S+ S- H+ H- Panel Supervised S+ S+ S- H+ H- S+ S+ S- H+ H- Su P r r r v r u Supervised S S 8 S . 41. :. Signal Circuit inial 111111 Signal Circuit \ OO Mt" 11111END LINE RESISTOR O / ERE LINE RESISTOR mai \ O O / END OF LINE RESISTOR O NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. - • When synchronizing the GE3 12VDC Series,the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications • The audible and/or visible signal shall be Gentex GEH,GESS, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service (FM)and the California State Fire Marshal (CSFM). The notification appliance (combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-175 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton Important Notice: 551-0050-06 • G E N T E X These materials have been prepared by Gentex Corporation('Gentex')for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Genies makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,stale and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainly regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. FIRE SYSTEM ACCESSORY Model 5495 tSILENT Distributed Power Module i KNIGHT In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power • Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sensor®,Gentex®,AMSECO®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control • Stand alone operation /Communicator.The 5495 is the cost- • Lightweight design adds to ease of effective solution for powering installation and reduces shipping in ' 9 notification appliances required by the costs Americans with Disabilities Act(ADA). • Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern, which can upgrade older control panels that lack cadence • ANSI Cadence pattern output capability. capability built-in SI LI.\I Features Connection to Local Fire Control • UL Listed for 6 amps of notification The 5495 may be connected to a local Model 5495 fire control which utilizes Class A or power Class B type notification circuits Distributed Power Module • Power supply's advanced switch operating between 9 and 32 VDC. The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the • UL Listed more efficiently than other systems 5495.The control panel's notification • MEA 429-92-E Vol XII • Dip switches allow for easy circuit end-of-line resistor is also • CSFM 7300-0559:123 reconfiguration connected across two terminals on the • NFPA 72 • 24 VDC filtered output voltage 5495,which provides supervision • Four power-limited notification between the 5495 and the fire control • OSHPD (CA)OSP-0065-10 outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual (see accessories) Class A and 2 Class B notification devices are then connected • Additional continuous auxiliary to the 5495 signal circuits using the output 4.7kc2 end-of-line resistors provided. Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs; 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the control panel. FIRE SYSTEM ACCESSORY Model 5495 . Distributed Power Module Model 5495 Block Diagram Signal Circuit OutputSignal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output L Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • • Earth ground fault Notification (0° to 49° C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 k_Q EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification Accessories: No. of inputs 2 AC input: 120 VAC at 2 amps SK-SCK Seismic Compliance Kit Input Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A • SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350395 Rev F subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-7161 Phone: (800)328-0103, Fax: (203)484-7118.For Technical Support, please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY 4110SILENT Addressable Photoelectric 1 KNIGHT Smoke Detector by Honeywell Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS approximately every 15 seconds, Analog /Addressable indicating that the head is Photoelectric Type communicating with the loop. The Smoke Detector LED lights continuously during the The SD505-APS is particularly alarm period. • suited to detecting dense smoke • 'r typical of fires involving materials Features • such as soft furnishings, plastic, Low profile, 2 inches, including foam or other similar materials base which tend to smolder and produce • Simple and reliable addressing large visible particles. without mechanical switches SD505-APS Smoke Detector • Automatic compensation for The detector features automatic sensor contamination Specifications compensation for contamination Operating Voltage: 17-41 VDC • Built-in fire test feature and a simple detector calibration • Simple detector calibration Current Consumption: test procedure that can be run from the panel or remotely (using the testing through the control panel Standby: .55 mA WindowsTM based downloading or remotely through a Alarm: .55 mA software). WindowsTM based computer Ambient Temperature:32°F to 120°F software. (0°C to 49°C) Operation • Vandal-resistance locking The SD505-APS units made up of features Mounting: 4"Square, 4" an LED light source and a silicon OCT, Single g • Field cleanable gang mud ring photo diode receiving element. In a . UL listed, meets NFPA 72 Ch 7 normal standby condition, the Relative Humidity: 85% requirements receiving element receives no light CSFM approved noncondensing •from the pulsing light source. In the Air Velocity: 0-300 FPM • event or fire, smoke enters the MEA approved detector and light is reflected from • FM Approved Compatible Bases: SD505-6AB the smoke particles to the receiving (Sold Separately) SD505-61B • element. SD505-6RB SD505-6SB The light received is converted into an electronic signal. Under normal conditions, the status LED blinks INTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric • Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter=5-15/16" N Diameter=3-15/16" � N ►I i \\\\(O \\SSI kryF P r Height=2 inches, .., including base \ t1 ( / SIlEM/ IQVICHT Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover Ni KNIGHT all specific applications or anticipate all requirements.All specifications are • subject to change without notice. For more information,contact Silent FORM#350225 Rev D by Honeywell well Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2010 Honeywell International Inc. Phone: (800)328-0103, Fax:(203)484-7118. www.silentknight.com