Report l
1.002-(
Page 1 N:\JOBS Stone Bridge\1852\1852 Beams\1852-367-BEAM A.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 11:40:09
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO RECEIVED
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE TWITH CHANGING BUILDING CODES, J U L 1 bp 2015
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. 9;-T
COMPANY: STONE BRIDGE HOMES NW LLC CI OF TIGAR D
JOB ID: 1852-367-BEAM A BUILDING DIVISION
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 11.000' 0.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 6499 19561 5601 0;194 0.355
ALLOWABLE 13994 27280 11845 0.407 0.610
STRESS INDICES 0.46 0.72 0.47 L/756 L/412
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 303 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 65" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1.
12.500'
TOTAL SPAN: 12.50 FT
T T
Page 2 1852-367-BEAM A.dsn
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (PT) X2 (FT)
ALL 1. UNIF DEAD ROOF TOP - �W262.7 PLF 6.000 12.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 12.500
+ALL 1 *UNIF DEAD FLOOR SIDE 82.5 PLF 0.000 12.500
+ALL 1 UNIF WEIGHT BEAM 17.8 PLF 0.000 12.500
ALL 1 CONC DEAD ROOF TOP 881.0 LBS 6.000
1 1 UNIF LIVE ROOF TOP 394.0 PLF 6.000 12.500
+1 1 *UNIF LIVE FLOOR SIDE 165.0 PLF 0.000 12.500
1 1 CONC LIVE ROOF TOP 1321.5 LBS 6.000
2 1 UNIF LIVE ROOF TOP 0.0 PLF 6.000 12.500
+21 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 12.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 6.000
+3 1 *UNIF LIVE FLOOR SIDE 220.0 PLF 0.000 12.500
4 1 UNIF LIVE ROOF TOP 525.3 PLF 6.000 12.500
4 1 CONC LIVE ROOF TOP 1762.0 LBS 6.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 19561 5601 1.00
2 8833 2512 0.90
3 12929 3854 1.00
4 19041 5289 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 4538▪ 6499
2 2154 2938
3 3529 4313
4 3958 6311
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2154 2938
2 2154 2938
3 2154 2938
4 2154 2938
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2384▪ 3561
2 0 0
3 1375 1375
4 1804 3373
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.554 3.554
CONCENTRATED LOADS
SPAN TYPE El (LBS) X1 (FT) MIN ERG (IN)
1 DEAD 881.0 6.000 3.000
1 LIVE 1762.0 6.000 3.000
Page 3 1852-367-BEAM A.dsn
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.194 0.407 L/756 0.355 0.610 L/412
2 1 0.000 0.407 0.162 0.610 L/906 0.162 0.242
3 1 0.079 0.407 1,/1856 0.240 0.610 L/609
4 1 0.180 0.407 L/815 0.341 0.610 L/429
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.72 0.47
2 0.36 0.24
3 0..47 0.33
4 0.70 0.45
SLENDERNESS RATIO = 2.26 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 N:\JOBS Stone Bridge\1852\1852 Beams\1852-367-BEAM B.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 11:47:00
WARNING
- T
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1852-367-BEAM B
STATE: OR CODE: IBC
PRODUCT: 1-PLY 7" X 11-7/8" LP LVL 2900Fb-2.0E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 19.000' 15.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
---ter- -�- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 7051 24526 6907 0.348 0.490
ALLOWABLE 18658 39805 15794 0.473 0.710
STRESS INDICES 0.38 0.62 0.44 L/490 L/348
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
*-** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT.
STRUCTURAL GEOMETRY
-------------------
SPAN 1
14.500'
TOTAL SPAN: 14.50 FT
LOAD PATTERNS
-------------
CASL SPAN SHAPE IYI'E SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL- 1�_ UNIFY DEAD FLOOR SIDE 258.8 PLF 0.000 14.500
+ALL I UNIF WEIGHT BEAM 23.8 PLF 0.000 14.500
+1 1 UNIF LIVE FLOOR SIDE 690.0 PLF 0.000 14.500
+2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 14.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1�' 24526 6907 1.00
7125 2007 0 .90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS S FOR TOTAL LOADS
Page 2 1852-367-BEAM B.dsn
CASE BRG#1 BRG#2
1 7051 7051
2 2048 2048
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
--77-
2048 2048
2 2048 2048
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 5002 5003
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
-------- --- ----
3.554 3.554
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
--------
1 1 0.348 0.473 L/490 0.490 0.710 L/348
2 1 0.000 0.473 0.142 0.710 L/1197 0.142 0.214
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.62 0.44
2 0.20 0.14
SLENDERNESS RATIO = 1.70 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 N:\JOBS Stone Bridge\1852\1852 Beams\1852-367-BEAM C.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 11:52:24
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD--E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY; STONE BRIDGE HOMES NW LLC
JOB ID`: 1852-367-BEAM C
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEADSAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 17.000' 8.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----- -- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 3497 8232 3393 0.108 0.150
ALLOWABLE 9329 18187 7897 0.323 0.485
STRESS INDICES 0.37 0.45 0.43 L/1083 L/774
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE TIIE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
10" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 468 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 119" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN
10.000'
TOTAL SPAN: 10.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING Ni W2 X1 (PT) X2 (FT)
Page 2 1852-367-BEADS C.dsn
+ALL 1 *UNIF DEAD FLOOR SIDE 187.5 PLF 0.000 10.000
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 10.000
+1 1 *UNIF LIVE FLOOR SIDE 500.0 PLF 0.000 10.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 10.000
A INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 8232 3393 1.00
2 2347 967 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#.2
1 3497 3497
2 997 997
REACTIONS FOR DEAD LOAD
-----------------------
CASE BRG#1 BRG#2
1 997 997
2 997 997
REACTIONS FOR LIVE LOAD
-----------------------
CASE BRG#1 BRG#2
1 2500 2500
2 0 0
MINIMUMBEARING SIZES" (IN)
BRG# 1 BRG# 2
3.554 3.554
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L%? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 _ 0.108 0.323 1/1083 0.150 0.485 L/774
2 1 0.000 0.323 0.043 0.485 L/2715 0.04.3 0.064
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.45 0.43
2 0.14 0.14
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD SE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 12:19:57
WARNING
-
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1852-367-BEAM D
STATE: OR CODE: IRC
PRODUCT: 1-PLY 7" X 11-7/8" LP LVL 2900Fb-2.OE
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
FLOOR 40 15 NO 0.000' 19.000' SIDE L/360 L/240
ROOF 30 15 2.000' 0.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS, ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----- --�— REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 8966 33681 11252 0.307 0.530
ALLOWABLE 35401 39805 15794 0.412 0.618
STRESS INDICES 0.25 0.85 0.71 L/484 L/280
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
** COMPRESSION EDGE BRACING REQUIRED AT EACH ENIl OF COMPONENT.
STRUCTURAL GEOMETRY
SPAN
13.000'
TOTAL SPAN: 13.00 FT
LOAD PATTERNS
CASE SPANSHAPETYPE SOURCE LOADING WI W2 X1 (FT) X2 (FT)
ALL 1 iNIF LEAD ROOF TOP 262.7 PLF 4.000 10.000
+ALL 1 UNIF DEAD FLOOR SIDE 142.5 PLF 0.000 13.000
ALL 1 UNTF DEAD WALL TOP 100.0 ELF 0.000 10.000
+ALL 1 UNIF WEIGHT BEAM 23.8 PLF 0.000 13.000
ALL 1 UNIF DEAD FLOOR SIDE 15.0 PLF 10.000 13.000
+ALL 1 UNIF DEAD ROOF TOP 15.0 PLF 0.000 13.000
ALL I CONC DEAD ROOF TOP 2449.7 LBS 10.000
ALL 1 CONC DEAD ROOF TOP 1112.7 LBS 4.000
.1 UNIF LIVE HOOP TOP 394.0 PLF 4.000 10.000
+1 1 UNIF LIVE FLOOR SIDE 285.0 PLF
0.000 13.000
1 714IF LIVE FLOOR SIDE 30.0 ELF 10.000 13.000
t1
UNIF LIVE ROOF TOP 22.5 OLE 0.000 13.000
1 1 CONC LIVE ROOF TOP 3674.5 LBS 13.000
1 1 COLIC LIVE ROOF TOP 1669.0 LBS 4.000
Page 2
2 _ UNIF LIVE ROOF TOP 0.0 PLF 4.000 10.000
+21 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 13.000
2 1 UNIF LIVE FLOOD. SIDE 0.0 PLF 10.000 13.000
+2 _ UNIF LIVE ROOF TOP 0.0 PLF 0.000 13.000
2 CONC LIVE ROOF TOP 0.0 LBS 10.000
2 _ CONC LIVE ROOF TOP 0.0 LBS 4.000
+3 _ UNIF LIVE FLOOR SIDE 380.0 PLF 0.000 13.000
3 1 UNIF LIVE FLOOR SIDE 40.0 PLF 10.000 13.000
4 1 UNIF LIVE ROOF TOP 525.3 PEE 4.000 10.000
+4 1 UNIF LIVE ROOF TOP 30:.0 PLF 0.000 13.000
4 1 CONC LIVE ROOF TOP 4899.3 LBS 10.000
4 1 CONC LIVE ROOF TOP 2225.3 LBS 4.000
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 33681 11252 1.00
2 14223 4633 0.90
3 21522 7067 1.00
4 32922 11023 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 8966 11369
2 3862 4678
3 6346 7254
4 8183 11024
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
3862 4678
2 3862 4678
3 3862 4678
4 3862 4678
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 5104 6691
2 0 0
3 2484 2576
4 4321 6346
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
6.743 8.574
CONCENTRATED LOADS •
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 2449.7 10.000 3.000
1 DEAD 1112.7 4.000 3.000
1 LIVE 4899.3 10.000 3.000
1 LIVE 2225.3 4.000 3.000
LIVE LOAD DEFLECTION 'TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL, ALLOW. L/? ACTUAL ALLOW. L,/? INSTANT LONG-TERM
1 1 0.307 0.412 L/484 0.530 0.618 L/280
Page 3
2 1 0.000 0.412 0.224 0.618 L/663 0.224 0.336
3 1 0.113 0.412 L/1309 0.337 0.618 L/440
4 1 0.296 0.412 L/502 0.519 0.618 L/286
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.85 0.71
2 0.40 0.33
3 0.54 0.45
4 0.83 0.70
SLENDERNESS RATIO = 1.70 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 N:\JOBS Stone Bridge\1852\1852 Seams\1852-367-BEAM J.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 13:41:24
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD--E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD--E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1852-367-BEAM E
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 14" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 19.000' 5.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
___________ REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 8909 23198 7590 0.141 0.210
ALLOWABLE 13994 37048 13965 0.357 0.535
STRESS INDICES 0.64 0.63 0.54 L/910 L/612
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 10" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 10" OC. TO THE UN--NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
***MAX.IMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 523 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 67" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
1.000'
TOTAL SPAN: 1.1.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 Xi (FT) X2 (FE)
Page 2 1852-367-BEAM J.dsn
ALL 1 UNIF DEAD FLOOR TOP 225..0 PLF 0.000 11.000
+ALL 1 *UNIF DEAD FLOOR SIDE 183,8 PLF 0.000 11.000
ALL 1 UNIF DEAD WALL TOP 100.0 ELF 0.000 11.000
+ALL 1 UNIF WEIGHT BEAM 21.0 PLF 0.000 11.000
1 _ UNIF LIVE FLOOR TOP 600..0 PLF 0.000 11.000
+1 1 *UNIF LIVE FLOOR SIDE 490,0 PLF 0.000 11.000
2 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 11.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 11.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 23198 7590 1.00
2 7587 2456 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 8909 8909
2 2914 2914
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2914 2914
2 2914 2914
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 5995 5995
2 0 0
MINIMUM BEARING SIZES (IN)
--------------------------
BRG# _ BRG# 2
3.554 3.554
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. Li? INSTANT LONG-TERM
1 1 0.141 0.357 L/910 0.210 0.535 L/612
2 _ 0.000 0.357 0.069 0.535 L/1871 0.069 0.103
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MGI VSI
1 0.63 0.54
2 0.23 0.20
SLENDERNESS RATIO = 2.67 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTiKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
Page 3 1852-367-BEAM J.dsn
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 N:\JOBS Stone Bridge\1852\1852 Beams\1852-367-BEAM F.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 13:48:34
WARNING
EEEEEEE
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 20 .4.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUIL?ING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1852-367-BEAM F
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 22" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 19.000' 5.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
-------_--- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 16685 5519616525 0.309 0.437
ALLOWABLE 16685 85765 21945 0.639 0.958
STRESS INDICES 1.00 0.64 0.75 L/743 L/527
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 4 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 4 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONTACT HANGER MANUFACTURER TO VERIFY ABILITY OF HANGER TC DISTRIBUTE LOAD
*** CONCENTRATED SIDE LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
THIS CONNECTION AND RESTRAINT OF THE TORSION INDUCED BY THE SIDE
LOAD ON THE MEMBER ARE THE RESPONSIBILITY OF THE PROJECT DESIGNER.
***MAXIMUM SIDE LOAD FOR M_1LTI-PLY CONNECTION DESIGN
MAX. LOAD: 523 PLF IDE: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 44" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
Page 2 1852-367-BEAM F.dsn
19.500'
TOTAL SPAN: 19.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 183.8 PLF 0.000 19.500
+ALL 1 UNIF WEIGHT BEAM 33.0 PLF 0.000 19.500
ALL 1 CONC DEAD FLOOR TOP 1923.0 LBS 2.000
ALL 1 CONC DEAD FLOOR TOP 1923.0 LBS 16.000
ALL 1 *CONC DEAD FLOOR SIDE 818.2 LBS 17.500
ALL _ *CONC DEAD FLOOR SIDE 162.8 LBS 17.000
ALL _ *CONC DEAD FLOOR SIDE 153.8 LBS 2.500
+1 1 *UNIF LIVE FLOOR SIDE 490.0 PLF 0.000 19.500
1 CONC LIVE FLOOR TOP 5128.0 LBS 2.000
1 1 CONC LIVE FLOOR TOP 5128.0 LBS 16.000
1 1 *CONC LIVE FLOOR SIDE 2181.8 LBS 17.500
1 1 *CONC LIVE FLOOR SIDE 434.2 LBS 17.000
1 1 *CONC LIVE FLOOR SIDE 410.2 LBS 2.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 19.500
2 :1. CONC LIVE FLOOR TOP 0.0 LBS 2.000
2 1 CONC LIVE FLOOR TOP 0.0 LBS 16.000
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 17.500
2 1 *CCNC LIVE FLOOR SIDE 0.0 LBS 17.000
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 2.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LES) LDF
1 55196 16525 1.00
2 16145 4737 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1. BRG#2
1 15361 16685
2 4424 4785
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 4424 4785
2 4424 4785
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 10937 11.900
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.901 4.237
CONCENTRATED LOADS
SPAN TYPE WI (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 1923.0 2.000 3.000
1 DEAD 1923.0 16.000 3.000
DEAD 618.2 17.500 3.000
DEAD 162.8 17.000 3.000
DEAD 153.8 2.300 3.000
Page 3 1852-367-BEAM F.dsn
1 LIVE 5128.0 2.000 3.000
1 LIVE 5128.0 16.000 3.000
1 LIVE 2181.8 17.500 3.000
1 LIVE 434.2 17.000 3.000
1 LIVE 410.2 2.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L;? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.309 0.639 L/743 0.437 0.958 L/527
2 1 0.000 0.639 0.127 0.958 L/1806 0.127 0.191
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.64 0.75
2 0.21 0.24
SLENDERNESS RATIO = 4.19 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 N:\JOBS Stone Bridge\1852\1852 Beams\1852-367-BEAM G.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 14:02:06
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED) USERS AN UPDATED VERSION OF THE WOOL-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1852-367-BEAM G
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (0) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 8.000' 4.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
---- REACTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 3851 10692 3460 0.177 0.280
ALLOWABLE 9329 18187 7897 0.390 0.585
STRESS INDICES 0.41 0.59 0.44 L/795 L/502
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
***MAXIMUM SIDE LOAD FOR MULTI--PLY CONNECTION DESIGN
MAX. LOAD: 220 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 63" O.C. OR LESS,
STRUCTURAL GEOMETRY
SPAN 1
12.000'
TOTAL SPAN: 12.00 FT
LOLL P :TT SNS
Page 2 1852-367-BEAM G.dsn
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
A▪LL UNIF DEAD WALL TOP 100.0 PLF 0.000 7.500
+ALL _ *UNIF DEAD FLOOR SIDE 90.0 PLF 0.000 12.000
ALL I UNIF DEAD FLOOR TOP 60.0 PLF 0.000 7.500
+ALL I UNIF WEIGHT BEAM 11.9 PLF 0.000 12.000
ALL _ CONC DEAD FLOOR TOP 109.1 LBS 7.500
+1 I *UNIF LIVE FLOOR SIDE 240.0 PLF 0.000 12.000
1 1 UNIF LIVE FLOOR TOP 160.0 PLF 0.000 7.500
1 1 CONC LIVE FLOOR TOP 290.9 LBS 7.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 12.000
2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 7.500
2 1 CONC LIVE FLOOR TOP 0.0 LBS 7.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PEE.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LES) LDF
1 10692 3460 1.00
2 3979 1292 0.90
UNFACI'ORED SUPPORT REACTIONS (LES) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
C▪ASE BRG#1 BRG#2
1 3851 3051
2 1477 1055
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1477 1055
2 1477 1055
REACTIONS FOR LIVE. LOAD
CASE BRG#1 BRG#2
1 2374 1997
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 3RG# 2
3.554 3.554
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1 (FT) MIN ERG (IN)
1 DEAD 109.1 7.500 3.000
1 LIVE 290.9 7.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.177 0.390 L/795 0.280 0.585 1./502
2 1 0.000 0.390 0.103 0.585 1.,/1358 0.103 0.155
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ***`"
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ***-*
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (0) ✓R
TWICE THE LENGTH FOR. CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
Page 3 1852-367-BEAM G.dsn
1 0.59 0.44
2 0.24 0.18
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 N:\JOBS Stone Bridge\1852\1852 Beams\1852-367-HDR H1.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/02/15 19:17:09
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD--E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OF. METHODS OF ANALYSTS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1852-367-HDR H1
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 2.000' 35.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD •
ACTUAL 3338 4941 2380 0.052 0.072
ALLOWABLE 9329 11932 6318 0.207 0.310
STRESS INDICES 0.36 0.41 0.38 L/1433 L/1033
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT.
STRUCTURAL GEOMETRY
SPAN 1
6.500'
TOTAL SPAN: 6.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (CT)
--ALL 1 UNIT DEAD FLOOR -OP 277.5 PLC 0.000 6.500
ALL 1 UNIT WEIGHT BEAM 9.5 PLC 0.000 6.500
7. UNI1:• LIVE FLOOR TOP 740.0 PLC 0.000 6.500
Page 2 1852-367-HDR H1.dsn
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500
INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSE.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 4941 2380 1.00
2 1381 671 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 3338 3338
2 933 933
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 933 933
2 933 933
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2405 2405
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.554 3.554
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. Li? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1.._.._ 1 0.052 0.207 L/1433 0.072 0.310 L/1033
2 1 0.000 0.207 0.020 0.310 L/3696 0.020 0.030
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.41 0.38
2 0.13 0.12
SLENDERNESS RATIO 2.71 LIMIT = 10.00
VERIFY YOUR. INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP ".,VL, LP LSL, OR. LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
•
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 12:34:37
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1852-367-HDR H2
STATE: OR CODE: IRC
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
FLOOR 40 15 NO 0.000' 19.000' TOP L/360 L/240
ROOF 30 15 0.000' 0.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 6022 8323 5763 0.076 0.131
ALLOWABLE 6022 11932 6318 0.211 0.316
STRESS INDICES 1.00 0.70 0.91 L/1001 L/579
LOAD CASE 1 1 4 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY 3E USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT.
STRUCTURAL GEOMETRY
SPAN 1
6.500.
TOTAL SPAN: 6.50 FT
LOAD PATTERNS
-------------
CASE SPAN SHAPE TYPE SOURCE LOADING `M1. W2 XI. (FI) X2 (FSC)
Page 2
ALL 1 UNIF DEAD ROOF TOP 262.7 PLF 1.500 5.500
+ALL 1 UNIF DEAD FLOOR TOP 142.5 PLF 0.000 6.500
+ALL _ UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500
+ALL I UNIF WEIGHT BEAM 9.5 PLF 0.000 6.500
ALL _ CONC DEAD ROOF TOP 1112.7 LBS 5.500
ALL _ CONC DEAD ROOF TOP 881.0 LBS 1.500
1 1 UNIF LIVE ROOF TOP 394.0 PLF 1.500 5.500
+1 1 UNIF LIVE FLOOR TOP 285.0 PLF 0.000 6.500
1 1 CONC LIVE ROOF TOP 1669.0 LBS 5.500
1 1 CONC LIVE ROOF TOP 1321.5 LBS 1.500
2 1 UNIF LIVE ROOF TOP 0.0 PLF 1.500 5.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 5.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 1.500
+3 1 UNIF LIVE FLOOR TOP 380.0 PLF 0.000 6.500
4 1 UNIF LIVE ROOF TOP 525.3 PLF 1.500 5.500
4 1 CONC LIVE ROOF TOP 2225.3 LBS 5.500
4 1 CONC LIVE ROOF TOP 1762.0 LBS 1.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 8323 5579 1.00
2 3515 2324 0.90
3 5415 3225 1.00
4 8026 5763 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 5080 6022
2 2153 2530
3 3388 3765
4 4820 5951
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2153 2530
2 2153 2530
3 2153 2530
4 2153 2530
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2927 3492
2 0 0
3 1235 1235
4 2668 3421
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
1.935 2.294
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1. (FT) MIN BRG (IN)
1 DEAD 1112.7 5.500 3.000
DEAD 881.0 1.500 3.000
LIVE 2225.3 5.500 3.000
Page 3
1 LIVE 1762.0 1.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.076 0.211 L/1001 0.131 0.316 L/579
2 1 0.000 0.211 0.055 0.316 L/1374 0.055 0.083
3 1 0.029 0.211 L/2636 0.084 0.316 L/903
4 1 0.072 0.211. L/1050 0.127 0.316 L/595
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.70 0.88
2 0.33 0.41
3 0.45 0.51
4 0.67 0.91
SLENDERNESS RATIO = 2.71 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
•
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 14:18:01
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AIN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1852-367-HDR H3
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 9-1/2" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 1.5 NC 0.000' 19.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 4798 15364 5162 0.161 0.239
ALLOWABLE 7166 17898 9476 0.278 0.417
STRESS INDICES 0.67 0.86 0.54 L/621 L/419
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF 16d. (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 57" C.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
8.500'
TOTAL SPAN: 8.S ) FT
COAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) Xi (FT)
Page 2
+A.LL.: 1 UNIF DEAD FLOOR TOP 142.5 PLF 0.000 8.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 8.500
+ALL 1. UNIF WEIGHT BEAM 14.3 PLF 0.000 8.500
ALL 1 CONC DEAD FLOOR TOP 1385.5 LBS 3.500
+1 UNIF LIVE FLOOR TOP 380.0 PLF 0.000 8.500
.1 CONC LIVE FLOOR TOP 3694.5 LBS 3.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 8.500
2 1 CONC LIVE FLOOR TOP 0.0 LBS 3.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 15364 5162 1.00
2 4896 1697 0.90
•
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG41 BRG#2
1 5695 4798
2 1906 1662
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1906 166.2.
2 1906 1662
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 3788 3136
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
2.162 1.820
CONCENTRATED LOADS
SPAN TYPE W1 (LES) X1 (FT) MIN BRG (IN)
1 DEAD 1385.5 3.500 3.000
1 LIVE 3694.5 3.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.161 0.278 L/621 0.239 0.417 L/419
2 1 0.000 0.278 0.078 0.417 L/1286 0.078 0.117
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.86 0.54
2 0.30 0.20
SLENDERNESS RATIO -- 1.81 LIIIT = 10.00
•
Page 3
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERi'AINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS,A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 07/03/15 14:36:11
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUA'T'ION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1852-367-HDR H4
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 16" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 0.000' 19.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
-- --- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 16392 38963 15376 0.401 0.577
ALLOWABLE 16392 47475 15960 0.539 0.808
STRESS INDICES 1.00 0.82 0.96 L/484 L/336
LOAD CASE 3 3 3 3 3
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***A'T'TACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 1.2" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES,
ADDITIONAL FASTENERS MAY BE REQUIRED.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 40" O.C. OR LESS,
STRUCTURAL GEOMETRY
SPAN 1
16.500'
TOTAL SPAN: 16.30 FT
LOAD PATTERNS
-------------
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
Page 2
+ALL 1 UNIF DEAD FLOOR TOP 142.5 PLF 0.000 16.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 1.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 14.500 16.500
ALL 1 UNIF DEAD FLOOR TOP 30.0 PLF 1.500 14.500
ALL 1 UNIF DEAD ROOF TOP 30.0 PLF 1.500 14.500
+ALL 1 UNIF WEIGHT BEAM 24.0 PLF 0.000 16.500
ALL 1 CONC DEAD FLOOR TOP 3100.6 LBS 14.500
ALL 1 CONC DEAD FLOOR TOP 2445.3 LBS 1.500
+1 1 UNIF LIVE FLOOR TOP 285.0 PLF 0.000 16.500
1 1 UNIF LIVE FLOOR TOP 60.0 PLF 1.500 14.500
1 1 UNIF LIVE ROOF TOP 45.0 PLF 1.500 14.500
1 1 CONC LIVE FLOOR TOP 6201.3 LBS 14.500
1 1 CONC LIVE FLOOR TOP 4890.5 LBS 1.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 16.500
2 1 UNIF LIVE FLOOR TOP 0.0 PLF 1.500 14.500
2 1 UNIF LIVE ROOF TOP 0.0 PLF 1.500 14.500
2 1 CONC LIVE FLOOR TOP 0.0 LBS 14.500
2 1 CONC LIVE FLOOR TOP 0.0 LBS 1.500
+3 1 UNIF LIVE FLOOR TOP 380.0 PLF 0.000 16.500
3 1 UNIF LIVE FLOOR TOP 80.0 PLF 1.500 14.500
3 1 CONC LIVE FLOOR TOP 8268.4 LBS 14.500
3 1 CONC LIVE FLOOR TOP 6520.7 LBS 1.500
4 1 UNIF LIVE ROOF TOP 60.0 PLF 1.500 14.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 33607 12939 1.00
2 11953 4494 0.90
3 38963 15376 1.00
4 13826 4873 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BR.G#2
1 12782 13801
2 4530 4894
3 1.5131 16392
4 4932 5272
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 4530 4894
2 4530 4894
3 4530 4894
4 4530 4894
REACTIONS FOR LIVE LOAD
CASE BRG#1. BRG#2
1 8252 8907
2 0 0
3 10601 11498
4 402 378
MINIMUM BEARING SIZES (IN)
BRG# I BRG# 2
3.843 4.163
CONCENTRATED LOADS
Page 3
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 3100.6 14.500 3.000
I. DEAD 2445.3 1.500 3.000
1 LIVE 8268.4 14.500 3.000
1 LIVE 6520.7 1.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.320 0.539 L/606 0.496 0.808 L/391
2 1 0.000 0.539 0.176 0.808 L/1102 0.176 0.264
3 1 0.401 0.539 L/484 0.577 0.808 L/336
4 1 0.026 0.539 L/7511 0.202 0.808 L/961
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.71 0.81
2 0.28 0.31
3 0.82 0.96
4 0.29 0.31
SLENDERNESS RATIO = 3.05 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.