Loading...
Plans (34) PITCH: 20 ARRAY PITCH:20 MP1 AZIMUTH:225 ARRAY AZIMUTH: 225 MATERIAL: Comp Shingle STORY: 1 Story • a a a -9 a m a s a a • ® . LEGEND s r a a �M r a a • 0 (E) UTILITY METER & WARNING LABEL • D s a ® INVERTER W/ INTEGRATED DC DISCO Q -3 O & WARNING LABELS ® DC DISCONNECT & WARNING LABELS \ i AC ® AC DISCONNECT Sc WARNING LABELS I L D'J Q DC JUNCTION/COMBINER BOX & LABELS o u9ocke,time, 0 0 o w D DISTRIBUTION PANEL 8c LABELS Front Of House LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR (E)DRIVEWAY CONDUIT RUN ON INTERIOR GATE/FENCE 15780 Southwest Highland Court 0 HEAT PRODUCING VENTS ARE RED r/.7.1 '( 11 INTERIOR EQUIPMENT IS DASHED L-J TOTAL ARRAY AREA (SF): 399 SITE PLAN , c, TOTAL ROOF AREA (SF): 3205 Scale:1/16" = 1' CO TOTAL ARRAY AREA IS a 12.44 Ol' 16' 32' 4 PERCENT OF TOTAL ROOF AREA ■■m— limim• CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBERPREMISE OWER: DESCPoP110N: DESIGN' CONTAINED SHALL NOT BE USED FOR THE J B-9723287 0 0 ��4 ■ BRENT BIRKEMEIER Brent Birkemeier RESIDENCE Dan Dochylo ,,\cOla f�'�� BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MWNTING SYSTEM: �.,�r.7 �/. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15780 SOUTHWEST HIGHLAND COURT 5.72 KW PV ARRAY • PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION NTH MODULES' TIGARD, OR 97224 3055 earvIew Way THE SALE AND USE OF THE RESPECTIVE 22) REC # REC260PEZ PACE NNE SHEET: REV DATE Son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2—OUTD—S—US—Z—A SITE PLAN PV 2 5/9/2016 (888)—SOL—CITY(765-2489)www.solarcity.com PRE-MANUFACTURED TRUSS STRUCTURE MEETS THE (E) 2x4 PV MODULE PRESCRIPTIVE REQUIREMENTS " INSTALLATION ORDER - OF THE OSSC SECTION 3111 5/16 BOLT WITH __ / FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. ® (4) ) SEAL PILOT HOLE WITH 2 POLYURETHANE SEALANT. „..... .......*\ \ ZEP COMP MOUNT C iig :;-i fs * WNW:ismi �1 �' (3) INSERT FLASHING. r ZEP FLASHING C ta�.�� � r 2-2" 7'-g" �5'-4"-/ 7'-2" / (E) COMP. SHINGLE v'I ImoiP- -i--4(7c PLACE MOUNT. + (E) LBW (E) ROOF DECKING VALliell 11111111 INSTALL LAG BOLT WITH SIDE VIEW OF MP1 NTS 5/16" DIA STAINLESS (5) (5) SEALING WASHER. A STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES (6) INSTALL LEVELING FOOT WITH WITH SEALING WASHER BOLT & WASHERS. MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) \ LANDSCAPE 72" 24" STAGGERED (E) RAFTER PORTRAIT 48" 20" 4/01 STANDOFF TOP CHORD 2x4 @ 24"OC ROOF AZI 225 PITCH 20 STORIES: 1 Scale: 1 1/2" = 1' ARRAY AZI 225 PITCH 20 BOT CHORD 2x4 @24"OC Comp Shingle CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-9723287 00 PREF OMER: DES BOR DESIGN: SoIarCity CONTAINED SHALL NOT BE USED FOR THE BRENT BIRKEMEIER Brent Birkemeier RESIDENCE Dan Dochylo BENEFIT OF ANYONE EXCEPT SMARMY INC., MOUNTING SYSTEM NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15780 SOUTHWEST HIGHLAND COURT 5.72 KW PV ARRAY , PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 3055 ge«vIew Way THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZP NAME SHEET: REV DALE San Mateo,CA 94402 SOLARgTY EQUIPMENT, WATHOUT THE WRITTEN T:(650)638-1028 F:(650)638-1029 I PERMISSION OF SOLARCITY INC' ABB # PVI-4.2-OUTD-S-US-Z-A STRUCTURAL VIEWS PV 3 5/9/2016 (880—SOL—MY(ass-24�).....alaran ", Y.�a . UPLIFT CALCULATIONS • 05.09.2016 ".4 PV System Structural Version#56.4 .t., �/ Desi a n Software pwrjeat3nflormatilon&Table Of Contents Risk Category: II PV System Type SolarCity SleekMount'" Camp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 20° Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area . 391 sf PV Module Width 39" PV Module Length 66" Standoff(Attachment Hardware) Comp Mount Type C Reduced Grolnnl/Roof live/Snow Loads Ground Snow Load pg 25.0 psf '' ASCE Table 7-1 Surrounding Roof Snow 100% 25.0 psf "ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind Design Criteda Wind Design Code ASCE 7-05 Wind Design Method Partlally/FuM Endosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C ' Section 6.5.6.3;, Roof Style Gable Roof 'Fig.e-11B/C✓o-14A/B Mean Roof Height h 15 ft Section 6.2 Effective Wind Area(1 Module) A 17.8 sf IBC 1509.7.1 WindPresent*Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 6-3 Topographk Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Tie 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(VA2)(I) Equation 6-15 _ 16.7 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/C/D 14A/B Ext Pressure Coeflident(Down) GCp(Down) 0.45 Ag.6-nne/cfo-14A/B Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure tipp(up) -146 psf Wind Pressure Down p(down) 10.0 psf til: d Spacings R-Deertion ir.ficrectiee Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape' 24" NA Standoff Configuration Landscape Staggered Max StandoffTributay Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wird Uplift at Standoff T-actual -252 lbs Uplift Capadty of Standoff T-allow 500 lbs §lbanthdf`.)emand/C ty DCII 503% Max Allowable Standoff Spacing Portrait 48" 66" Max Alowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered . Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift*Standoff T-adual -282 lbs Uplift Capadty of Standoff T-allow 500 lbs SandoffDernmetichvadtv DCR 56.4% PREMISE OWNER: DESCRIPTIOik DESIGN: CONFIDENTIAL- THE INFORMATION USED HEREIN JOB NUMBER: g-8723287 00 Dan Dochylo �!+'�OI��rI4. CONTAINED SHALL NOT BE USED FOR THE BRENT BIRKEMEIER Brent Birkemeier RESIDENCE � �,,g Y• BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEIk ��� NOR SHALL IT BE DISCLOSED IN %MOLE OR IN Comp Mount Type c 15780 SOUTHWEST HIGHLAND COURT5.72 KW PV ARRAY . PART To OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODt ES TIGARD, OR 97224 3055 aa«nIew Way THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ P NAME SHEET: REV DATE Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN /IR T:(650)638-1028 F:(650)638-1029 . PERMISSION OF soiARcyTY INC. ABB # PVI-4.2-OUTD-S-US-Z-A UPLIFT CALCULATIONS PV 4 5/9/2016 (888)—SOL—CITY(765-2489)www.eolarcNY.cn GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE • BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:S404081200 Inv 1: DC Ungrounded INV 1 -(1)ABB # PVI-4.2-OUTD-S-US-Z-A LABEL: A -(22)REC REC260PEZ OR # 180498 • RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24 550 138 FCI Inverter; Zigbee 4200W, 240V, 96% PV Module; 260W, 236.6W PTC, MC4, 40mm, Block Frame, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 37,8 Vpmax: 30.7 • INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER • E 200A MAIN SERVICE PANEL (E) 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! (E) WIRING CUTLER—HAMMER Inverter 1 IND 200A/2P Disconnect (� ABB W Dc+ Vstart = 200V A PV1-4.2—OUTD—S—US—Z—A DC- MP 1: 1x11 d b • (E) LOADS EGC / L2 25A/2Pid_ N � DC- ......--- G I O Vstart = 200V ___ GND _ EGC/ ■� DC+ /SDC+ A Z��— GEC N DG 4 MP 1: 1x11 • B- I fl GND I----E --- ----E- ----- .Gc J N J ca EGC/GEC � Z-Z — T GEC r Y TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE ICEI I I I I I i I I I Voc* = MAX VOC AT MIN TEMP POI (1)SIEMENS I Q PV BACKFEED BREAKER A (1)CUTLER-HARMER DG221UR8 Breaker, 25A/2P2 spaces Disconnect; 30A,�240Voc, Non-Fusible, NEMA 3R AC DC -(2)Gr 4d Roil -(1)CUTLER-HAMMER I DGO3ONB 5/8 x 8, Copper Ground/Neutral Kit; 30A, General Duty(DG) TITAWG#10, THWN-2, Black _. _ _ _ _ O L �(1)AWG/10, THWN-2, Red J (2)AWG/10,PV YVxe, 600V, Black Voc* =458.46 VDC Isc =9.01 ADC L (1)AWG/10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=2.0 MC Ol (1)Con X10,t; 3/4.DAT Green EGC Vmp =337.7 VDC Imp=8.5 ADC III���(1)Conduit Kit; 3/4�EMT -(1)AWG/8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4'EMTAWG , ir , = .46 = O ((21)AWG/10/10,PV WIHHNe,/THWN600V-2, (,Peen Blade EGC Voc*Vmp =337458.7 VDCVDC ImpIsc =8.59.01 ADC LCL(1)Conduit Kit; 3/4'EMT CONFIDENTIAL- THE INFORMATION HEREIN JOB MINEERPREMISE Off: DEDESIGM CONTAINED SHALL NOT BE USED FOR THE JB-9723287 00 ��i, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: BRENT BIRKEMEIER Brent Birkemeier RESIDENCE Dan Dochylo �:,;So�arCit . 48 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 15780 SOUTHWEST HIGHLAND COURT 5.72 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS • ORGANIZATION, EXCEPT IN CONNECTION YMTH MOanES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ 3055 pie"Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NATE: SHEET: REV DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER T:(650)638-1028 F:(650)638-1029 ABB # PVI-4.2—OUTD—S—US—Z—A THREE LINE DIAGRAM PV 5 5/9/2016 (888)-SOL-CITY(765-2489). ..ealarcity.aan, Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM ACA (AC)(P01) (P01) CURRENT Per Code: Per Code: OPERATING WARNING Per Code: • IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 INVERTER OUTPUT NEC 690.64.6.7 OPERATING VOLTAGE CONNECTION DO NOT RELOCATE Label Location: THIS OVERCURRENT PHOTOVOLTAIC DC (DC)(INV) DEVICE DISCONNECT Per Code: NEC 690.14.C.2 Label Location: WARNING (AC)(P01) Per Code: Label Location: ELECTRIC SHOCK HAZARD Label Location: DO NOT TOUCH TERMINALS NEC 690.17(4) WARNING (DC)(INV) MAXIMUM POWER- A (DC)(INV) TERMINALS ON BOTH LINE AND ELECTRIC SHOCK HAZARD Per Code: POINT CURRENT(Imp)- LOAD SIDES MAY BE ENERGIZED NEC 690.35 F Per Code: IN THE OPEN POSITION THE DC CONDUCTORS OF THIS ( ) MAXIMUM POWER-_V NEC 690.53 PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT VOLTAGE (Vmp) UNGROUNDED AND INVERTER IS MAXIMUM SYSTEMV MAY BE ENERGIZED UNGROUNDED VOLTAGE(Voc)_ SHORT-CIRCUIT (Isc) A Label Location: CURRENT(Isc) PV SYSTEM (AC) DISCONNECT FOR UTILITY OPERATION Label Location: WARNING (DC)(CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 DC VOLTAGE IS HAZARD. DO NOT TOUCH ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT WARNING (DC)(INV) MAXIMUM AC Per Code: OPERATING VOLTAGE ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 Label Location: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC AC (AC)(P01) (AC): Disconnect Per Code: (C)):: Conduit DISCONNECT (CB): Combiner Box • NEC 690.14.C.2 Label Location: (D): Distribution Panel La La (POI) (DC): DC Disconnect CAUTION (D)Per Code: (IC): Interior Run Conduit PHOTOVOLTAIC SYSTEM 1 NEC 690.64.B.4 (INV): Inverter With Integrated DC Disconnect CIRCUIT IS BACKFED (LC): Load Center (M): Utility Meter (P01): Point of Interconnection ' CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR Oh/ 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED «� •' San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �"r�it►` T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION MIH THE SALE AND USE OF THE RESPECTIVE ►��SolarCity (688}SOL-CIfY p65 2489)www.solarcity.com SOLARCITY EQUIPMENT, MIITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. AN 13 ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4 ZeS oa r 3/26/15 3/26/15 P ZepSolar This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing= calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Load Duration Wind Snow design load landscape= 15.35 27.64 27.64 psf Uplift= 656 lbs N/A ��. ., +C' �'� design load Portrait= 12.28 27.64 27.64 psf Lateral= 357 lbs 290 lbs a� 85618 note:use 10 psf minimum Down Force= 1074 lbs 771 lbs Snow Calculations OREGON c., V To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. �°' c' Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for sloes above 30 Attachment Spacing Calculations ��,. ��� P Uplift Spacing EXPIRES: 12/31/16 degrees. Allowable Uplift Load FOR PAGES 1-4 uplift spacing= Ground Snow Load= 30 psf module length or width x design load Roof Pitch Wind Uplift Calculations 14 30 .. 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf P=qh GCN (snow load spread over the length of the rafter) qh=0.00256 K,Kit Kd V2 I Down Force Load Roof Pitch Basic Wind Speed= 120 mph Combinations: 14 30 Exposure= C Roof Zone= Edge Zone D+S= 31.16 25.10 psf Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof Kzt= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.75S 31.59 31.91 psf Vorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force Iscape effective area= 13.0 ft2 GCN portrait=-1.5 iortrait effective area= 21.7 ft2 landscape down force spacing= 39"x 3L91psf x 144 in =89" Pia"dscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf 7711bs in portrait down force spacing= 65"x 31.91psf x 144-ft2 = 53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf 656 lbs landscape uplift spacing = 39" 27.73 psf x 144f-t2 = 87" ' 656 lbs portrait uplift spacing = 65"x 25 89 psf x 144 portrait =56" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 Zep S o tar 3/26/15 3/26/15 Zep So to r Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing=-1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load Maximum Uplift Pressure Landscape= -27.73 lateral spacing = module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf ps=Cs Pf Roof Pitch= 31 45 degrees landscape module spacing = -1.4545 x 31.91 psf+120.7273= 74" pt=0.7 Ce Ct I pg Ce= 0.9 Cs= 0.71 0.45 Cf= 1.2 pf= 22.68 22.7 psf portrait module spacing= -0.8182 x 31.91 psf+79.909=54" I= 1.0 ps= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral 30° 27° 30° Lateral Force Component 74" 48" 44 Down Force Load Roof Pitch Module Deflection 74" 54" Combinations: 27 30 31 45 D+S= 13.50 14.49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75'0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 2901bs in landscape lateral spacing = 39"x 14.49 psf x 144 ft2 =74" 2901bs in portrait lateral spacing= 65"x 14.49 psf x 144 ft2 =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2901bs in portrait lateral spacing= 65"x 13.50 psf x 144 ft2 =48" tA, ® .rel `,'SOiarCity ZepSolarNext-Level PV Mounting Technology 'ilSOlarCity ZepSolar Next-Level PV Mounting Technology II Zep System Components for composition shingle roofs 40 40 . O r, 4. . ,. p-roof Q A, Leveling Foot ° L, ©rorad ® ,„.,.-,f: ` "M"" Part No.850-1172 le.eting cr of 1 ETL listed to UL 467 = +ice Zeperos. r , Root Attaclv�et :` ' ` 'efArray Skirt - Comp Mount � � Part No.850-1382 11111 4, ;t Listed to UL 2582 Mounting Block Listed to UL 2703 QGpMPgT�� -4 4 4e614141 ti� �,% Description • PV mounting solution for composition shingle roofs FA a • Works with all Zep Compatible Modules coMPf'' • Auto bonding UL-listed hardware creates structural and electrical bond �,` • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from • any manufacturer certified as"Type 1"or"Type 2" ()LISTED Interlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 II& kek • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, o0 zepsolar.com zepsolar.com L Listed ,to UL 115656850-1467 5 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps.zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps'zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM a s • Solar inverters Additional highlights: max• we" "'° - RS-485 communication interface (for connection to laptop or data logger). =i ' -_ 1 ; - Integrated Arc Fault Detection and , €° Interruption(-A Version). t i; Am i :',1-::::::::let:,,,4:;,,,,, WI t,Technical data and types Type code PVI-3.0 OUTD US PVI-3.6-OUTD-US PVI 3.8-OUTD-US PVI-4.2-OUTD US i.;;Ii-it!roi4ig-qi, ANI Mechanical specifications . Nominal output power 3000W 3600W 3300 3800W 4200W Maximum output power wattage 3000 3300' 3300' 3600 4000' 4000' 3300 4200' 4200' 4200 4600' 4600' Rated grid AC voltage.............. .................. .........2 8V 2 0V... 277V 2 8V 2 0V ....277V 2V 24V 277V 208V ....2 0 V 27777 ... 40V � � � Input side(DC) - Number of independent MPPT channels 2 2 2 2 Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj.120-350V) -'1';':!P,': c Fut power MPPT voltage range 160-530V 120-530V 140-530V 140-530V ' `� -• Operating MPPT voltage range 0.7 x Vstart 580V(>=90V) ..... Maximum current(Idcmax)for both MPPT in 20A 32A 32A 32A parallel Maximum usable current per channel 10A 16A 16A 16A Maximum shortcircuit current limit per 12.5A 20.OA 20.OA 20.OA ' channel >a Number of wire landing terminals per channel 2 pairs u ?`u` Array wiring termination Terminal block,pressure clamp,AWG10 AWG4 -- • a i 3.. Output side(AC)° Grid connection type 10/ Split- 10/ 10/ Split 10/ 10/ Split 10/ 10/ Split 10/ 0/3W .._........... ............... ......... ......... .........2W 0/3W 2W...... 2W2W 2W 0/3W 2W 2W 0/3W 2W...... Adjustable voltage range(Vmin Vmax)M 183 217 244- 183- 211- 244- 183- 211 244 183 211- 244- 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V Grid frequency...... 60Hz..... Adjustable able grid frequency range 67-60 5Hz Maximum current(les m°,) 14 5 14.5 12.0 - 17.2 1 16.0 16.0 16.0 16 0 16.021.20 0 20.0 20.0 .............ANws ....A,,,,,,, A„rns....- Anis.......Anms.......Anrns _Ani Anms ... Aerns l...An,,� i....An". ...ANms..... Power factor >0.995 This familyof single-phase The high-speed MPPT offers real- Highlights: Total harmonic distortion at rated power <2% stringGrid wiring termination type Terminal block,Pressure clamp,AWG10 AWG4 inverters complements the typical time power tracking and improved - Single phase and split phase output Input protection devices number of rooftopsolarpanels energyharvesting. Reverse polarity protection Yes g. grid connection. Over-voltage protection typeVanstor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection ........ . ... ... Prerestart-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of the property. a consistent and stable performance - The high speed and precise MPPT Anti-i protection 4 Meets UL 1741/IEEE1547 re uirements Overge protection type Varistor,2 IL Lz/L G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A„„„ 20A„„5 15A„„G 25A„ 20A„„s 20A,,n 20A„„, 20A„„G 20A„,,,, 25A,,,,s 25A,,,, •25A,„ This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96.9% 97% 97% s7 CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure Operating perfornarice Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0,6W„„, This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8W„„, Communication installations with two different installations with reduced string size. - Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This ruggedmonitoring outdoor inverter has been in compliance with international Remote monitorinn g(1xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions. (For designed to be a completely sealed Standards(-S Version). efeko runental Ambient air operating temperature range 13°F to+140°F with derating above 122°F(50°C) example: East and West) unit able to withstand the harshest AmbientA 9 p 9 air storage temperature range -40°F to+176°F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidit .....Y .,... ........... 0-100%RH condensing ................ .. .......... .............. _..... Acoustic noise emission level independent MPPT enable a more <50 db(A)WI m IL ,I II 1 Maximum operatingdat nominal altitutde without derating6560 ft(2000 m) optimal energy harvesting condition. pOWer and productivity .Capability enableAC voltage and wth suf(c ent DC power available for a better world'"' ��.wID 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD • s ,, e vv �• �y �� RCC v.v A \ ENERGIZING LIFE TOGETHER `< ' f z — _ `�� .'. f .404 ,44M-7'!","!."-•- X04 41 r ° r r � � � 8R at � ' i ,« ILe Z -''''-''''''';',4*.-s `tae €f z ti, iit fir. ° r, r ` r. y' I g v � rw. 8 y r�� ga.; t-.1-t,, �, z�l _ a :� .„ $ �' � 1 � t UMW • a., �$ �€y r6 .z= <.� ;" -fit { r T£ y I iii ii $ s.. r 4 t s i V A All measurements in inches .7 _, 9 ✓ # \\ .se % ;.a A: t';Ts'"+ .t' a v r REC260PEZ 3` -xE �', Z e '' E ' ' ��s� _. NominalPower-PM„r,(Wp) r ” € 260 is ' t a ( WattQassSorting(WP) / S s a r. T � Watt.1PowerVoltage-VMne(V) 307 i" y' \\ € f �, 'f€ _ \ \ omina ower Cu - ) \\ N IP C t IMeP(A B50 �� r d '` sf �\ \ Open GrcuitVoltage-Vpt(V) 37 8 t 4. R .k: � 'q "� i. '� Short Circuit Current-Isc(A) 901 Iti 7 f > 4N0 Panel Efficiency(%) 7 ::tom €'*11,410457:7i s cIi s.„ , `' \ The electrical ch ager sties are w thin+/IO%'AP f tl dicated values of I55r Vr„and Pw at standard Test conditions(STCI. '?,- - v `.. 'ly :%i'1,�,+ . Values at standard test conditions STC(:41°"96: air ss AM 15C'"717 in ad once 1000 /m,cell temperature 77°F(ZS°C)I i %�a rr.., r At lnw irradianre of 200 W/m'(AM5& ell temperature 77°F(25°ql at least 97%of the STC panel efficiency will:2:2:9:: �,(, >rt a s�,a^ �` -.i<�t 's'' A R�? <' \j.� NominalPowePMWp)NominalPowerVoltage V (V ,i r� ..`s .., ��t. � a� as��. K ,.. ` OpenlCircutVoltage-V c(V)(A)) � � �-rr ,"� � �� 35.7 :::::::::'1'.'..-.1.; . ',. d t 0 7.24 , . `,, ,,r'.. � '\ \,h \� ShortGrcuitCurrent Isc(A) e;, �, . '`1 Nom-r al operating cell temperature NOCT(tl00 W/m',AM IS,windspeedl m/s ambient temperature 6tl°F(20°C) 144 444 4. ftp � e ' s ° 4..„\ .t 'ii a ',a fit'V A , 10yearproductwarranty. , =.a ,� "\ V \� A C �L us 25 year linear power output warranty s ti, lllfEE (max.degression in performance of 0.7%p.a.). ,: ;' rr „ii- i, frAgoAtupt \ , UL 1703,Fire rating.Type 1,ClassC iyp +t . ;:-, .�. ✓,, .n+ V � \ �r.• if' REC is a leading global provider of solar energy solution• s. With more than 15 years of experience,we offer sustainable,high performing '\ ' `\ \ ', products,services and investments for the solar industry-Together with our partners,we create value by providing solutions that better %y,;`Z R C C ... ...:i • `� '_, ,,,, `ti meet theworld'sgrowing energy needs.RFC's headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Our 1,600 ,,,,,,, \ \ employeesworldwidegeneratedrevenuesofUSD647millionin2013. www.recgroup.com ,, _:, ,1.'I'.: r , ',:\ Alik \� \ \ �` 4 S 13 °^SOiarCity Zep Solar Next-Level PV Mounting Technology ___ DWV Debris Guard for composition shingle roofs PHOTOVOLTAIC MODULE _-----_..- jj DWV DEBRIS GUARD 1.____<011111111111111------ _. r' COMP ROOF MOUNT ;000 COMP ROOF jjjjjj/ j O DWV Debris Guard Construction Detail Debris Guard,close up • ,00 Prevent blockages and keep vents open with the DWV Debris Guard. c 7 Ar: pct^ • • Protects against: F,,®0 • Leaves • Rain • Pine needles • Insects • Snow • Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. zepsolar.com C This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1677-001 Rev A Date last exported:April 3,2015 4:04 PM f