Loading...
Plans (27) Arc e oiC. - 0030 SPECIFICATIONS STANDARD ENGINEERING NOTES I 0/Z-t0 Sw e-,J' S-i ,S2 . Ir... 7, Foundation, special inspection, footings, anchor bolt embedment, O Stafford Item Code #36 edge distances and all reinforcing are to be designed by a Vinyl foam NSF gasket (1/16" joint thickness), Cam-lock layout #2, Profile #2 (4" HD) qualified professional engineer based on concrete strength and lJ 7 specific soil condition at the building site. L�U�7 M Foundation and freezer pit to be designed for loads designated on SPECIAL INSTRUCTIONS plan and/or in engineering calculations. 47 47 44718 �u TMOi (, Meets 2009 Federal Energy Independence and Security Act Requirements. All foundation dimensions to be field verified. Standard crating All mechanical unit anchorage and support to be designed by r___________ _————-1 Comm's. Nim others. CP WALL PANELS All connectors or elements in contact with aluminum to be C P All ® 10372 SW BONANZA WAY ILO Construction: 4' high density urethane stainless steel (STL/STL). TIGARD,OREGON 97220 /� Exterior Finish: Stucco galvalume If walk-in ceiling is suspended, existing roof structure to be 503-317-1023 w Interior Finish: Stucco galvalume designed by others for loads induced from new walk-ins where as x Lksaucturaligprnalcom Ceiling connections: Camlock shown on plans and/or in engineering calculations. Cl C2 i >K a i C3 /� Floor connections: Camlock Walk-in is designed for code applied loads. r W Design does not include static pressure review. ' CEILING PANELS Components of all doors, windows, and openings to be designed for �'�� Construction: 4" high density urethane loads induced by wind, design by others. es x ^ Exterior Finish: Metal All loads are service loads. moi/ Interior Finish: Stucco galvalume Special Inspection is required per IBC 1704 and 1707 for post L______ ___——-J Ceiling Caps: Factory mounted installed anchor bolts (for California, follow CBC 1704 and Live Load: 10 psf 1707)• \\ FLOOR PANELS WARNING - ELECTRICAL SEAL Model: Hand-Truck Floor panels model #HTFN (NSF) After wiring devices, ALL conduits must be sealed to stop CEILING PANELS <S5: Construction: 3 1/2' high density urethane moisture transfer through electrical raceways. w/ .080 aluminum diamond tread @ interior Failure to seal device per NEC codes WILL VOID WARRANTY. over 1/2" plywood opC� w/ Metal @ exterior ��� I w/ 36" deep model #500I interior ram1Z41$16'p s DOORS ti% � �vb [A]: 36' x 78" flush model G3 self-closing freezer door VeitCkuuxTrin `�ny l�� _ *** LEAF WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE *** O(2)Places 11'-7'[139) �1^ ��l ',C\o h IS Frame: 4" high density urethane, 3-sided O 11 a1 w/ Stucco galvalume (ext. & int.) HDPvIdn=500# � _���1 111 w/ 24 ga. stainless steel 430 (magnetic) liners Typcal(2)Places (^ V w/ 3-sided heat cable in frame [FL-3-105W] :....4314 35.114 47 47 4 ® C; `5 ''''' 1 (33'-1" x 3.5 ohms @ 3.2 watts/ft + Pepi - 110V, 1A) e H y f Leaf: 4" thick, 3-side lap, standard height m ; W3 W4 W5 � , w/ Stucco galvalume (ext. & int.) t, Vii" Ie w/ Magnetic gasket w/ Heated sweep Self-regulated heat wire (120V, 0.3A max.) ' ; t (3) Component Hardware #W59 spring assisted adjustable hinge z II (1) Kason #27C cylinder locking deadbolt handle n� b. a. < � (1) Kason #270 twist-off knob inside release S- r` II .. > Di IC (1) Kason #1094 hydraulic door closer II ::::::!..] (1) Single pole toggle switch w/ pilot light @ ext. t, P (1) Digital 2" flush mount dial thermometer (j (1) Kason 1832 heated air vent (23W, 120V, .2A) e Z (1) 14 ga. stainless steel threshold for interior ramp ; W11 I W10 ; W9 Ii N = 611 1 PARTS 143/4 351/4 47 47 41/4 H De (2) ea. (2" x 4') x 96' x stucco galvalume inside corner vertical closure2 liklmi (2) ea. (2' x 4") x 48" x stucco galvalume inside corner vertical closure (1) ea. (HEIGHT" x 1") x 93" x stucco galvalume ceiling closure (ship later) mDGWP WALL PANELS N c.)cc i Es 1 ON O (3) ea. 11" x 11" ceiling closure braces ce nI Ci iIINP $$$��� (1) ea. 4' LED light fixture w/ (2) LED lamps for cooler or freezer application it Q (1) ea. Low temp Chase Doors strip curtain for 36' x 78' net opening w/ 6" strips @ 33.00% overlap LUL J a Q ¢R (1) ea. Inside corner trim w/ huggers (3' x 3') x 16' x 26 ga, stucco galvalume ct Q D CD ct (21) ea. Prefabricated floor seismic restraint system Simpson Titen or similar concrete screws @ 24'o/c Y P' ill CI ill (6) ea. (2" x 2') x 96" x Stucco galvalume Interior seismic tie-down @ ceiling level - - REFRIGERATION --- /---- �'�c°fiCD e (1) ea. System #1 - Outdoor R404a split system w/ mounted parts / \ 0 ,N s 8323 BTU/H @ 9.39F TD with 14.8 hr runtime @ -102F inside/959F outside roome 902F @ cond. unit, 202ft altitude 84%.4--us./5-a 5 arocoA (1) Heatcraft air cooled condensing unit #MOH025L63CFT m 47 47 447/8 [a co a5 208-23OV/3e/60Hz/2.5HP Hermetic compressor f `g,ZsiFs2 MCA=21, MOPD =25 o 14118 (11 r•.. 3l"mat x 28.25D x 1profile x 259apo XXX I ����� ��� O / -+as o•• (1) Climate Control low p • • L' a l't°% • profile eva orator model #LSF090BMC6K-EC �_ C P C P C c‘I01pO0.k. w/ EC motors (0.96A) & electric defrost (7.8A) w/ mounted thermostat, solenoid valve & TXV i 2318' I�I 335/8' / 29 �G I N F ��f?� 452085W3xV14B84DHx 14.94H x 681bs. I " ✓ ** 2REVS DATE BY ® Fl F2 F3 , �' 60839PE r� OREGON SEAL N , 05/11/2016 JXB REVISIONS \ \ -- C,.-r,ON / #1: Engineering redlines. to \\�__ ^mac g 3 I. ' pt,i SC DO NOT SCALE THIS DRANING FLOOR PANELS ^- SCALE: 3/16"=1V-0' 0 NSF LABEL EXPIRES: 6 30 k ' DATE DRAWN: 5/4/2016 DATE PRINTED: 5/12/2016 N.S.F. LISTED (STD #7) BY: JXB N.S.F. GASKET @ ALL PANEL JOINTS CHK)BY: DRW#: 16-IB$6473-01 BOX: 1 OF 1 SHEET: 1 OF 3 r l.irrxlulcS gin V.V. It7"' ' Ceding panel O prima �1r111r1� �� _ SPECIFY FINISH a 1 1 LAu1Y4 THOM* CEILING HEIGHT lt��� 1 • • COMMTING.Iu WriV 'Er ` /'i% O O O O I ,^ 1r/ \\............_01 - 10372 SW BONANZA WAY Backing @ it 2•x 2'x cont.x 26 ga.stuuo 9aMdlme {f, rTV, � 11GAftD,OREGON 97224 ' Zr li. E• 503.317-1023 w for strip tartan w/ff8 x 112•MTHSMS e 6 o/c at ea leg CCI N. N. X11 w/(4)#8 x 1/2'@ spices et ea leg . G £ f l 1� Licatructural�gmaicom --- (I 5' ) SPLICE DETAIL t N £,„dr, 111111 i ---� -.'- /60839PE t T II' wlpanel_ I DiCEILING TIE-DOWN DETAILfl' yClIIigh density frame panel, camlock (NTS) 'i I I 1n.�e' --,-`' asset• I W • WiglEWES- 6730 I ee g ELEVATIONi �Vg6JJ Fp \'',.__FINISHED i`FINISHED CEILING le b p ! a 1 CEILING CLOSURE s.rvmwlle.mmnwhmaea�g 11/2' XI XI 357/8 XI XI 1117 yu�11 Y� 1 I I I Edg.o(b �!C 1 e� 3 l CEILING PANEL + 4 ga. Stainless steel ` #8 x 3/4" MTHSMS ao \ n ges y V @ 12' O.C. \Ewe , File tri14 holm 1rlawn)04' WALL PANEL „ .n 2'FHx3/s-nlSMsa(4)114' I e', 4xY FH mcreMiww ndns 1 6. a-g g 17 ok ZO 1 \ 38 7/8 m IO NOTE: Do to construction variables seal threshold/jamb joint w/ silicone0OmOlitil • I —— i O¢ IIIIIN O • 4/ �fi as RO IC! t � ODCEI.LING CLOSURE DETAIL \VIII .r io 61/2' 0 1 RAMP INSERT 36'xWIC-1/8' j~�m� o Cr / 3 3l4' I / G d tH.'l('fODly " ® I/ k4/ INT. / Ramp notch 37314'-(Wel+118')xWIC+1/6' Rlu,amm� EXT. Wal Panel (.3 1., ' � 4• wan+118 a26 1 C110:71=0-0 =41 1 I Camlocks at 24'O.C.Typ- 1 3/4. / 1 Sides to be factory bu3 -mom-- � �� lad to match Wear surface a q 1%4'NSFRa6le wearsurface • w/ non-skid strips W.-1_ O 8rShop notch flr pnls 0=1 Ii6N to Double Wood Rip-downTyp. Offset stop a for taper aide lip /4' Underlayment ta.....O1fl,xi ei _ Flush door frame 3/16' x 1 1/4' Counter sink in tend for 1/2'x 61/7 Floor panel a k, Threshold Simpson Then HD ..or rams - B d REV# DATE BY M 24'O.C.grin.embed=2 A') Cr- beyond > Wearsurfaoe — 6$ 05/11/2016 JXB N Tir Floor Panel Fixed@ I Underlayment ,^ -- 13/4• I- 36' �, when specified f— .1 N. . 1 -fir .,N !1 sae floor spec. L.`— Finish ' Ai AIIIIIIMII. • Exposed side wedge to be factory clad to match wearsurface [A] Floor ;ll''•': i>• '� ':<;'•, "'1' a € • Stainless (smooth or diamond plate)floor=20 ga. Stainless wedge clad '''ti:.•, -., Aluminum (smooth or diamond plate) floor= ,080 smooth aluminum wedge clad Steel diamond plate or galvanized floor= 16 ga. Smooth gale wedge clad DO NOT SCALE THIS DRAWING COMPONENT LOCATIONS SCALE: 3/16'=1'-0' DATE DRAWN: 5/4/2016 DATE PRINTED: 5/12/2016 ' cREFAB FLOOR W/ 36" DEEP INTERIOR RAMP ()CAM LOCK & TIE-DOWN DETAIL CHKDBV: J XB 4" High density construction Flush door DRW#: 16-18$647$-01 BOX: 1 OF 1 SHEET: 2 OF 3 r V"" @ top 3l8iaexrod 0 Condensing unit 259 Lbs.208/230/30 Q z.156'Ihick ply.steel 1— 1 AT 1 Ceiling panel plate washers,w/3/8.0 M serrated flange nut&double 3/8'0 x 12'nylon bottom nut typ(I)min • 6=4 Maws a/I-Weal At exterior 3/81:10x rod 0 x.1561 ick �++0NANZ tJt jill111111111 • gale.steel plate washers ,/� ■ ■ 10372 SW BONANZA WAY • O TIGARD,OREGON 97224 CO / �'117 C\'i````` Ltcatmc uraleg23 icom Ali I 3' Ca 3l6'0 serrated longe 1 nuts @ext and int • AIR ''�` &..1...\,...:.......110...., r Wall panel lux FLOW C ••• _ Top wl 319'0 serrated (H)x 11/2 Ceiling panel .am =.... O flange nut(4)min t• . 1 ._L / i g 5 El 7 J ' I to 1 hp i '!' i 1 3/6'0 x 12'nylon o COIL HANGER DETAIL W/OVERSIZED WASHER COIL KIT max load 70 lbs per rodIii 1 0. .toad70#perrodCoil kits supplied only if included on Imperial-Brown quote (6)3/9id0x3•od0x.156'thickgalv.steel pleb washers Btm3/9'id0zrod 0 (6)3/8.0 x 12'ASTM A307 al-thread �� Wal panel x.156"thick gale.steel (12)3/6'0 serrated flange nuts �—— plate washers,w1300 (6)3/8.0 mks serrated flange nut&double bottom nut typ(4)nin lig 1 3 CONDENSER ANCHOR DETAIL W/OVERSIZED WASHER ()CONDENSER condenser kits supplied only if included on Imperial-Brown quote U Z 2 H m Iii1E1 t N m Omreii : li L,J E a g O S EXT. INT. ail rik' ill Rd Wall Panel - R0) 1 I 7/8• (5)SPACES @ 7/8• 11/4'O.C.=61M' W�cno,'a L 2" x 2" x 8" x 12 ga. galv. ��,.0ul g (6) #8 x 1/2' MTHSMS a� a� y EQ. Spaced W t. K I_I 7x6'z1? Floor O.N OA D[� II J�L_ N �O I /1� nNM0.fx `i