Loading...
Report RECEIVED ED LIYORICJUN Y 2016 It's time to get comfortable. Bu,L0/NG GARD DIVISION SUBMITTAL DATA For: Approval Order#: Date: 05/10/2016 Project: PIZZA CABOOSE Project#: TSJ05102016-05 Location: OREGON Purchaser: CALIBER MECH- DAN Submitter: YORK NW-TYLER CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: [ OTQ [ Permit#: aCi4 —09 Address: Ilti7c) kir z-Fa-r lhw-t Suite#: Br .�....�...� Date= e f /l f OFFICE COPY Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 Date 05/10/2016 Project Name YORK® PIZZA CABOOSE Project Number It's time to get comfortable. TSJ05102016-05 Client/Purchaser CALIBER MECH-DAN Submittal Summary Page Qty Tag# Model# Description 1 D7NQ060N11006NXY 5 Ton Single Stage, York Affinity Single Packaged R-410A Air Conditioner, 14.0 SEER/ 12.0 EER, Microchannel Condenser Coil, 108 MBH Output Single Stage Aluminized Steel Natural Gas Heat, 208/230-1-60 • LowNOx with York Corner Post 1 MM-838DNZ2460HEC ECONOMIZER,HORIZ,AFFINITY 1 S1-2EC06700124 Transformer Kit Equipment and commissioningbya factorytrained technician is recommended. start-up Contact your supplying distributor or sales representative for additional information &guidance. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 • - • If ® Affinity Page:3 IORK DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Cooling Performance Total capacity 56.5 MBH Sensible capacity 442 MBH sr.'' Refrigerant type R-410A ; Seasonal Efficiency(at ARI) 14.00 SEER :gg_.Ig .-.,..gEfficiency(at ARI) 12.00 EER = Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.5 °F Leaving WB temp. 58.2 °F Power input 4.00 kW Sound power 81 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity(Max) 107 MBH .."` Supply air 2000 CFM Ext.static pressure 0.6 IWG Heating input capacity(Max) 135 MBH 5 Ton Duct location Bottom • YORK Affinity Series Units are Manufactured at an ISO 9001 Registered DB temp. 118.3 °F Air temp.rise 58.3 °F Facility and Each Rooftop is Completely Computer-Run Tested Prior to Air AFUE 81.0 % Shipment. Stages 1 Unit Features Supply Air Blower Performance • Unit Cabinet shall be Constructed of G-90,Pre-Paint Textured Steel, Supply air 2000 CFM Certified at 500 Hours Salt Spray Test per ASTM-B117 Standards Ext.static pressure 0.6 IWG • Bottom and Side Electrical and Gas Utility Connections Duct location Bottom • Easy Access to all Components Motor rating 1.00 HP Power input 1.13 kW • Single Piece Water-Shed Top Cover and Drip Edge Elevation 0 ft. • Field Convertible Duct Connections from Horizontal to Downflow Allows Drive type DIRECT Greater Flexibility Speed tap COOL-D • Full Perimeter,Removable Base Rails with Built in Rigging and Access _ Electrical Data Provisions Power supply 230-1-60 • Non-Corrosive Condensate Pan Internally Sloped to Meet Strict Unit min circuit ampacity 43.2 Amps Requirements of ASHRAE 62-89 Indoor Air Quality Standard Unit max over-current protection 60 Amps • Scroll Compressor Dimensions&Weight • Advanced Microchannel Technology Used on Cooling and Gas Units.High Hgt 42 in. Len 49 in. Wth 49 in. Efficiency Rifled Tube with Enhanced Fin Used on Evaporator Coils and Weight with factory installed options 530 lbs. Select OD Coils. Clearances • Compressor is Internally Protected Against high Pressure and Temperature Right 24 in. Front 12 in. Back 0 in. • Standard Cooling Operation Down to 45°F `op 36 in. Bottom 0 in. Left 24 in. / • Variable Speed Direct Drive High Static Motor and Slide out Blower Note: Please refer to the tech guide for listed maximum static pressures Assembly arr Ilia ; � „ii. 7�,�Lv) ^'��"°"`'° •Ext ended Ten(10)Year Limited Parts Warranty when product is registered us /.:-. online within 90 days of purchase for replacement or closing for new home construction.This Warranty does not apply for R-22 or 3-Phase Systems. • Ten(10)Year Compressor Warranty • Twenty(20)Year Heat Exchanger Warranty on Residential Applications/Ten (10)Year Heat Exchanger Warranty on All Other Applications Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 inity - YORK® DNQ-14 SEER SSiinglee Pkg.G/E R-410A YAC Page:4 Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Factory Installed Options D7NQ060N11006NXY 1 Product Category: D York Affinity Single Packaged R-410A Air Conditioner Product Generation: 7 Product Identifier: NQ 14.0 SEER/12.0 EER 5 Ton Single Stage Nominal Cooling Capacity: 060 Microchannel Condenser Coil Heat Type and Capacity: N 110 108 MBH Output Single Stage Aluminized Steel Natural Voltage: 06 208/230-1-60. Additional Options: N Y' LowNOx with York Corner Post Field Installed Accessories Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 YORKA® Affinity Page:5 ffinity DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Typical Application Unit Typical Duct Applications ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT 4-, .,: .„ii:i:i:i I 1 "c"—: I I 1 _ • - i — 1 i +---'.. 1) I I I 1 1 1 1 l SLAB ON GROUND INSTALLATION Roof Curb Cross Section 3/4"x 1"WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE • 3lli -UNIT BASE RAIL WOOD NAILER-- COUNTERFLASHING 8'MIN.ABOVE FINISHED ROOF------- ;-� /� I t fil ;ttt stt 14' I ':ri's° 1 CANT STRIP :tt CURB FRAME - 1 -i$1' f INSULATION AND ROOFING MATERIAL I it INSULATION i I I /4 1\ 4 ROOF DECK AND ROOFING MATERIAL Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 • • ' aYORK® Affinity Page:6 DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Roof Curb Typical Application Unit Typical Roof Curb Installation (Gas Model Shown) MANUAL GAS SHUT-OFF VALVE _........„..../- ripir . 4 4 4 ..... . ...„. „, ------,..„.„..,„ FIELD SUPPLIED 8 DISCONNECT SWITCH yI m y MOUNTED ON UNIT \\T *73 / I I , 8 ll , r ,'��o TO POWER 10 ilili11111111111111111 111 SUPPLY 1 1111111111111'1 111 111111 TO GAS SUPPLY LINE CONTROL WIRING TO INDOOR THERMOSTAT RETURN T3. AIR DUCT SUPPLY AIR DUCT Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 • • - . yOligRK® Affinity Page:7 DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Roof Curb On Ground Installation Unit Typical Slab on Ground Installation (Gas Model Shown) FIELD SUPPLIED TO POWER SUPPLY CONTROL WIRING TO DISCONNECT SWITCH INDOOR THERMOSTAT LOCATED TO REAR OF UNIT / c� /� RETURN AIR \- DUCT -.••••••\ ----' 0 SUPPLY AIR DUCT TO GAS :00. � 1) . ' SUPPLY LINE 0 , j .?'fe., N Aporokr ,-.L.. N N ,. ./ .s,,,, Iiii.„.1c== ' 0,.1 MANUAL GAS o SHUT-OFF VALVE o N ,. , ••/00 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 . . • " rayoRK® Affinity Page:8 DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Dimensions&Clearances Gas Unit Dimensions VENT AIR OUTLET HOOD GAS SUPPLY BLOWER SERVICE ACCESS 1-1/4"DIAMETER HOLE COMPARTMENT PANEL CONDENSER COIL (1/2"NPTF CONNECTION) llr�i1 UNIT CONDENSATE (l`�t„`t! CONNECTION 3/4"NPTF 4-----.... ```...._ ��J A (TRAP RECOMMENDED) - � / ;;; B , 2-3/8 •::::!: CONN.1-3/8"DIA. + 4 .HIGH VOLTAGE ` ��;- KNOCKOUT .'- Illr-- Al � ) 0 ' REFRIGERANT 2-1/2 4� CONNECTIONS It t COMBUSTION AIR GAS SUPPLY `� , �� INLET LOUVERS 1-1/4"DIA.KNOCKOUT `\� ,�'l ; 'V 1/2"NPTF CONNECTION) ATV's-4°- FRONT LOW VOLTAGE I���5 3/8 CONN.1-3/8"DIA. 1-1/2 GAS/ELECTRIC CONTROL KNOCKOUT x 7/8"HOLE 11 12-3/4 SERVICE ACCESS 47-1/4 49-1/8 COMPARTMENT PANEL (OVERALL) (OVERALL) 3-1/3 N 2.5/8 Gas Unit Dimensions Unit Size Dimensions 'A" „B„ 024,030,0361 33-1/2 18-1/4 0362, 042,048,060 41-1/2 23-1/8 1. DNQ,DNZ Models. 2. DNX Models. Gas Unit Clearances1 2 Direction Distance Direction Distance (in.) (in.) Top' 36 Right • 12 Front 36 Left 24 Rear 0 Bottom4 0 1. A 1"clearance must be provided between any combustible material and the supply air duct work. 2. The products of combustion must not be allowed to accumulate within a confined space and recirculate. 3. Units must be installed outdoors.Over hanging structure or shrubs should not obscure condenser air discharge outlet. 4. Units may be installed on combustable floors made from wood or class A,B or C roof covering materials. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 • r - rayORK® fiff//�/�/ Page:9 DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Unit Dimensions Unit Dimensions Front and Bottom 0 0 N 1-7/819-1/4 HIGH VOLTAGE p 8-7/8 ' CONN. 1-3/32" d DIA.KNOCKOUT lit- F '' RONT ` GAS SUPPLY 1-5/8" l ___.---DIA.KNOCKOUT(1/2" � -4:- .41111�`t NPTF CONNECTION) LOW VOLTAGE P� CONN.7/8"DIA. R, f \ 4 moo. I, KNOCKOUT LOW VOLTAGE KNOCKOUT �\i; CONN.7/8"DIA. HIGH VOLTAGE ��'0 \ \ �e�l KNOCKOUT CONN.1-31/32"x 7/8" %� Nr � KNOCKOUT N. ,I VT,- \N .7 \� , dige 2-5/8 CONDENSATE �1:` o DRAIN 3/4"NPTF lj Of -1/2 26-3/4 7 43-112NX NsN22-112 NN‘N. ,7" V Unit Dimensions Back and Bottom SIDE SUPPLY 14-1/2 AIR OPENINGN. CONDENSER 28-3/8 COIL `� ls 1410ti. BACK BOTTOM SUPPLY ���� \AIR OPENING �% 3/8 e'% �/ 1 NO \ AIR OPEN NG N 11/ 1.--1," 7" 14-112 C /�` N0 4 '4-1/4 1-3/4 ` c •� 15 f 1 N. `' 1544 ,4e. 1-3/4 \ \ BOTTOM RETURN 28-9/16 / 171/ AIR OPENING // /1-3/4 f Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 . , . . • ✓ YORK® Affinity Page: 10 DNQ-14 SEER Single Pkg.G/E R-410A YAC Project Name: PIZZA CABOOSE Unit Model#: D7NQ060N11006NXY Quantity: 1 System: D7NQ060N11006NXY Sound Performance Sound Performance Outdoor Sound Power Levels Size Model Sound Rating Octave Band Centerline Frequency(Hz) (Tons) dB(A) 125 250 500 1000 2000 4000 8000 024 DNZ 77 64 65.5 68 72.5 64.5 60.5 48.5 (2.0) • DNQ 80 66 70.5 74 74.5 72.5 67.5 64.5 DNX 80 66 70.5 74 74.5 72.5 67.5 64.5 030 DNZ 74 63.5 64.5 66.5 67 63 57.5 51.5 (2.5) DNQ DNZ 74 66.5 66.5 69.5 68 63 59 49.5 036 DNQ 79.5 69 71.5 74 74 70.5 67 61 (3.0) DNX 80 70.5 71 74.5 74 71 67.5 64 042 DNZ 79 70 70.5 73.5 73 69.5 67 66 (3.5) DNQ DNZ 79 70.5 71 73.5 73 70 66 66 048 DNQ 80 71.5 71.5 73.5 74 69.5 65 63.5 (4.0) DNX 81 72.5 73 76 1 75.5 71 67.5 65 060 DNZ 80 73 71.5 74.5 75 70.5 67 62.5 (5.0) DNQ 81 73.5 73 76 75.5 71 66.5 61.5 1. Rated in accordance with ARI 270 standard. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/10/2016 r ,. ---.' (......c, V i 0 • Model 580D • I b r y a n tl S NGCOMIE PACKAGE ROOFTOPERCIAL Sizes 036-150 SAPP BUILDING DIVISION 121/2 Tons ® GAS HEATING/ELECTRIC COOLING JUN 1 2016 CITY OF TIGARD _ .__..._.---_-_.. ___..___.__.__.__.______ II 1 rill1W--- .....Mik„,_, IT--------: * LqOMIIIIPPIIII1____t--..---- -------1-____--- ,.....211.1.1.57 .1^- :---------- - 580D036-072 580D090-150 Standard-Efficiency Rooftop Units with: QUIET, EFFICIENT OPERATION AND DEPENDABLE PER- • Exclusive integrated gas control board with diagnostics FORMANCE—Compressors have vibration isolators for quiet • AlumagardTM heat exchanger coating operation. Efficient fan and motor design permits operation at • Induced-draft fan for gas combustion low sound levels and all 580D units are mounted either on • Tubular,dimpled heat exchangers mounting plate (036-072) or on an exclusive polycore plate • Pre-painted galvanized steel cabinet for long life and quality (090-150). appearance The 580D090-150 units offer lower utility costs through part- • Commercial strength base rails with built-in rigging capability load operation using 2 stages of cooling. • Convertible design to horizontal supply/return Quiet and efficient operation is provided by belt-driven evapo- • Non-corrosive, sloped condensate drain pan, meets rator fans (standard on all units over 5 tons). The belt-driven ASHRAE 62(IAQ) evaporator-fan is equipped with variable-pitch pulleys which • Two-inch return-air filters allow adjustment within the rpm ranges of the factory-supplied • A wide assortment of factory-installed options available pulleys. FEATURES/BENEFITS Increased operating efficiency is achieved through computer- designed coils featuring staggered internally enhanced copper Every compact one-piece unit arrives fully assembled, tubes. Fins are ripple-edged for strength, lanced, and double charged,tested,and ready to run. waved for higher heat transfer. INTEGRATED GAS CONTROLLER (IGC)—All ignition corn- Tubular, dimpled gas heat exchangers optimize heat transfer ponents are contained in the compact IGC which is easily for improved efficiency. The tubular design permits hot gases accessible for servicing. The IGC control board, designed and to make multiple passes across the path of the supply air. The manufactured exclusively for rooftop units, provides built-in dimpled design creates a turbulent gas flow to maximize heat- diagnostic capability. An LED (light-emitting diode) simplifies ing efficiency. troubleshooting by providing visual fault notification and system The California Air Quality Management Districts NOx require- status confirmation. ment of 40 nanograms/joule or less is met when Low NOx Kit The IGC also contains an exclusive anti-cycle protection for CRLOWNOX001A00 is installed on 036-060 sizes. gas heat operation. After 4 continuous cycles on the unit high- The extra thick AlumagardTM heat exchanger coating provides temperature limit switch, the gas heat operation is disabled, corrosion resistance and ensures long life. and an error code is issued. This feature greatly improves reli- ability of the rooftop unit. The unsightly appearance of flue stacks is eliminated and the effects of wind on heating operations are diminished by the The IGC also contains burner control logic for accurate and induced draft combustion system. The inducer fan draws hot dependable gas ignition. The LED is visible without removing combustion gas through the heat exchanger at the optimum the unit control box access panel. This LED fault-notification rate for the most effective heat transfer. The heat exchanger system reduces service person troubleshooting time and mini- operates under negative pressure, preventing flue gas leakage mizes service costs. The IGC also maximizes heating effi- into the indoor supply air. ciency by controlling evaporator-fan on and off delays. Form No. PDS 580D.36.9 • • During the Heating mode, the evaporator-fan relay automati- SIMPLE ELECTRICAL CONNECTIONS — Terminal boards, cally starts the evaporator fan after the heat exchanger warms located in the base unit control box, facilitate connections to up to a suitable temperature.The 30-second fan delay prevents room thermostat, outdoor thermostat(s), and economizer. Ser- . cold air from entering the supply duct system when the condi- vice panels are quickly removed,permitting easy servicing. tioned space is calling for heat to maximize efficiency. Thru-the-bottom service connection capability (with accessory) The direct-spark ignition system saves operating expense when allow power, control wiring, and gas to be routed through unit compared to pilot ignition systems. No crossover tube is base pan, minimizing roof penetrations.Gas,power,and control required, therefore no sooting or pilot fouling problems can connections are made on the same side of the unit to simplify occur. installation. All 580D standard units are designed for natural gas, but an In addition, color-coded wires permit easy tracing and accessory LP(liquid propane)conversion kit is available. diagnostics. SAFETY IS BUILT IN—All 580D units have a flame rectifica- PROVEN COMPRESSOR RELIABILITY—Design techniques tion sensor to quickly sense the burner flame and ignite burners feature computer-programmed balance between compressor, almost immediately. Fast shutdown is a certainty since the sen- condenser,and evaporator. Bryant-specified hermetic compres- sor reacts quickly to any flame outage or system failure. In the sors are equipped with compressor overcurrent and overtem- event of a shutdown,an error code is issued at the IGC board. perature protection to ensure dependability. Safety is also assured due to the heating safety controls which All 580D units have Bryant's exclusive fixed orifice metering will shut down the unit if there is a problem.If excessive temper- device which precisely controls refrigerant flow,preventing slug- atures develop,limit switches shut off the gas valve.After 4 con- ging and flood-back, while maintaining optimum unit perfor- tinuous short cycles of the high-temperature limit switch, the mance. Filter driers are standard. IGC board locks out the gas heat cycle to prevent any further INTEGRATED ECONOMIZERS AND OUTDOOR AIR — short cycles. This safety feature is provided exclusively on Optional economizers and manual outdoor-air dampers intro- Bryant rooftop units. The rollout switch also deenergizes the duce outdoor air which mixes with the conditioned air, improving gas valve in the event of a flame rollout. indoor air quality and often reducing energy consumption. DURABLE, DEPENDABLE CONSTRUCTION—Designed for During a first stage call for cooling, if the outdoor-air tempera- durability in any climate,the weather-resistant cabinets are con- ture is below the economizer control changeover set point, the structed of galvanized steel and bonderized, and all exterior discharge-air sensor modulates the economizer outdoor-air panels are coated with a prepainted baked enamel finish. The damper open to take advantage of free cooling provided by the paint finish is non-chalking, and is capable of withstanding outside air. When second-stage cooling is called for, the corn- ASTM (American Society for Testing and Materials) B117 pressor is energized in addition to the economizer. If the 500-hour Salt Spray Test.All internal cabinet panels are primed, outdoor-air temperature is above the changeover set point, the permitting longer life and a more attractive appearance for the first stage of compression is activated and the economizer stays entire unit. at vent position. Durablade economizer operation is controlled In addition, the 580D090-150 units are designed with a single, by a dry-bulb thermostat that senses outdoor-air temperature. continuous top piece to eliminate any possible leaks. Totally Accessory upgrade kits allow for either outdoor-air enthalpy enclosed condenser-fan motors and permanently lubricated changeover or for more precise differential enthlapy control. bearings provide additional unit dependability. The Durablade economizer (option or accessory) on the 580D EASY INSTALLATION AND CONVERSION — All units are units has a reliable sliding plate damper which is easily adjusted shipped in the vertical discharge configuration for fit-up to stan- for 100% outdoor air, 100% return air, or any proportions of dard roof curbs. (Two different curb sizes fit unit sizes 036-072 mixed air. and 090-150, respectively.)The contractor can order and install The 580D units can also utilize the field or factoryinstalled the roof curb early in the construction stage, before decisions EconoMi$er.The EconoMi$er is microprocessor controlled and on size requirements are made. incorporates a parallel,opposed-blade damper system. In addi- All units feature roll-formed base rail design with forklift slots tion, it has a spring return built into the damper actuator to pro- and rigging holes for easier maneuvering. (Forklift slots are vide reliable close-on-power-loss. The EconoMi$er comes found on 3 sides for 580D units.) The standard 580D036-060 equipped with up to 90% barometric relief capability for high units have operating weights under 500 lb and durable packag- outdoor airflow applications, ing protects all units during shipment and storage. In addition, the EconoMi$er power exhaust accessory can be The units can be easily converted from a vertical to a horizontal utilized to help maintain proper building pressure. discharge configuration by relocating the panels supplied with For units without economizer, year-round ventilation is the unit. enhanced by a manual outdoor-air damper (ordered as an The non-corrosive sloped condensate pan permits either an accessory or an option).The damper can be preset to admit up external horizontal side condensate drain (outside the roof to 50%outdoor air. curb) or an internal vertical bottom drain (inside the roof curb). INDOOR-AIR QUALITY(IAQ)BEGINS WITH BRYANT ROOF- Both options require an external,field supplied P-trap.Also,the TOPS—Sloped condensate pans minimize biological growth in condenser coil grille (available on 036-072 sizes as a field rooftop units in accordance with ASH RAE(American Society of installed accessory) provides a metal plate as an alternate loca- tion for the field supplied disconnect, if desired. Heating, Refrigeration, and Air Conditioning Engineers) Stan- dard 62.Two-inch filters with optional dirty filter indicator switch The 580D units were designed with service technicians in mind. provide for greater particle reduction in the return air.The face- The single-row condenser coils on the 580D036-072 and 090 split evaporator coils improve the dehumidification capability of units simplify the cleaning process.The efficient in-shot burners standard units, and enthlapy controls maximize building humid- and all ignition components are contained in an easily remov- ity control. able,compact assembly. Optional proportional reacting CO2 sensor is available with the The 580D units also have a standard filter access panel,which EconoMi$er to aid IAQ benefits. permits tool-less filter changes, even on units with horizontal economizers. 2 TABLE OF CONTENTS Page Page . Features/Benefits 1-2 Performance Data 16-38 Model Number Nomenclature 3 Electrical Data 39,40 ARI Capacity Ratings 3,4 Typical Piping and Wiring 41 Physical Data 5-8 Controls 42,43 Options and Accessories 9,10 Application Data 44 Base Unit Dimensions 11,12 Typical Wiring Schematic 45,46 Accessory Dimensions 13,14 Guide Specifications 47-49 Selection Procedure 15 MODEL NUMBER NOMENCLATURE 580D E V 090 180 C B 580D — Packaged Rooftop Evaporator-Fan Motor Options Standard Efficiency A —Standard Motor and Drive Gas/Electric Unit B —Alternate Motor and/or Drive Voltage Designation Factory-Installed Outdoor-Air and J — 208/230-1-60 Other Upgrade Options P — 208/230-3-60 A —Standard Unit E — 460-3-60 C —Durablade Economizer T — 575-3-60 H —25%Manual Damper M—Durablade Economizer,Controls Fuel and Control Type Upgrade Package*,and Condenser V — Natural Gas/Direct Spark Ignition Coil Grille N —25%Manual Damper,Controls Upgrade Package*,and Condenser Nominal Tons Coil Grille 036— 3 090 —7-1/2 T —Controls Upgrade Package*and 048— 4 102 —8-1/2 Condenser Coil Grille 060— 5 120 — 10 P —EconoMi$er 072— 6 150 — 12-1/2 L —EconoMi$er and Controls Upgrade Package(for use with Aernate Motor and Drive Gas Heat Input(Btuh) R —EconoMi$er and Controls) 074— 72,000 180 — 180,000 Upgrade Package(for use with 115— 115,000 224 — 224,000 Standard Motor and Drive) 125— 125,000 250 — 250,000 K—EconoMi$er,Controls Upgrade Package, 150— 150,000 and Condenser *Contains high pressure, (loss-of-charge) low-pressure, and freeze protection cutout switches. NOTE:The example model number 558DEV090180CB designates a 71/2ton 460-3-60 volt gas/electric rooftop unit with 180,000 Btuh nat- uragas heat,Durablade economizer and alternate drive. ARI*CAPACITY RATINGS UNIT NOMINAL STANDARD NET COOLING TOTAL SEERt SOUND 580D TONS CFM CAPACITY kW Belt Drive Direct Drive RATING (Btuh) (Bels) 36 3 1200 35,000 4.0 10.0 9.7 8.1 048 4 1600 47,000 5.5 10.0 9.7----- $.T _..` J 060 5 2000 57,000 6.7 T0.0 9.1 ts.l See Legend and Notes on page 4. 3 • ARI*CAPACITY RATINGS(cont) • NET COOLING SOUND UNIT NOMINAL STANDARD CAPACITY TOTAL EER RATING IPLV • 580D TONS CFM (Btuh) kW (Bels) 072 6 2100 72,000 8.0 9.0 8.1 ** 090 71/2 2800 85,000 9.6 8.9 8.7 9.35 102 81/2 3000 99,000 11.0 9.0 8.7 9.00 120 10 4000 117,000 13.0 9.0 8.8 9.35 150 121/2 4500 145,000 16.1 9.0 8.7 9.20 LEGEND Bels - Sound Levels(1 bel=10 decibels) db - Dry Bulb EER - Energy Efficiency Ratio IPLV - Integrated Part-Load Values SEER - Seasonal Energy Efficiency Ratio wb - Wet Bulb *Air Conditioning and Refrigeration Institute. tApplies only to units with capacity of 65,000 Btuh or less. **The IPLV applies only to two-stage cooling units. NOTES: 1. Rated in accordance with ARI Standards 210/240,latest revision(for sizes 036-120)or 360,latest revision(for size 150)and 270, latest revision. 2. ARI ratings are net values,reflecting the effects of circulating fan heat. 3. Ratings are based on: t. 1451,, qi..,a r.ccF 9�s>9N„n � S>ANO+P° Cooling Standard:80 F db,67 F wb indoor entering-air temperature and 95 F db air entering outdoor unit. IPLV Standard:80 F db,67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature. HEATING CAPACITIES AND EFFICIENCIES HEATING INPUT TEMPERATURE STEADY-STATE CALIFORNIA UNIT 580D (Btuh) OUTPUT CAPACITY RISE AFUE° EFFICIENCY SEASONAL Stage 2/Stage 1 (Btuh) (F) (/°) (°�0) EFFICIENCY (%) 036 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 I • 15 HI I : 600 92,000 55-85 81.0 :i �' 048 074 -/ 72,000 59200 • - 80.0 80.0 77.2 048115- 2, ---� 3555--- _-- -.80:0 ._. -80:0 _.. .._ 77.1. 5".-J 048 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 060 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 060115 -/115,000 92,000 35-65 80.0 80.0 77.1 060 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 072 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 072 115 -/115,000 92,000 35-65 80.0 80.0 77.1 072 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 090 125 -/125,000 100,000 20-50 80.0 80.0 75.8 090 180 180,000/120,000 144,000 35-65 80.0 80.0 77.1 090 224 224,000/180,000 179,200 45-75 80.0 80.0 77.1 102 125 -/125,000 100,000 20-50 80.0 80.0 75.8 102 180 180,000/120,000 144,000 35-65 80.0 80.0 77.1 102 224 224,000/180,000 179,200 45-75 80.0 80.0 77.1 120 180 180,000/120,000 144,000 35-65 80.0 80.0 77.1 120 224 224,000/180,000 179,200 35-65 80.0 80.0 77.1 120 250 250,000/200,000 200,000 40-70 80.0 80.0 76.4 150 224 224,000/180,000 179,200 35-65 80.0 80.0 77.1 150 250 250,000/200,000 200,000 40-70 80.0 80.0 76.4 LEGEND AFUE - Annual Fuel Utilization Efficiency NOTE:NOx levels are 40 nanograms/joule with the accessory NOx reduction kit(sizes 036-060). 4 PHYSICAL DATA-580D_036.07- lIllt , UNIT SIZE 580D 036 048 060 072 NOMINAL CAPACITY(tons) 3 4 5 6 OPERATING WEIGHT(Ib) Unit l Al/AI' 460 470 490 565 AI/Cu' 465 (-476 )\ 497 576 Cu/Cu* 468 482 505 587 Economizer Durablade 34 34 34 EconoMi$er 47 4 47 47 Roof Curbt 115 115 115 COMPRESSOR Reciprocating Reciprocating Reciprocating Scroll Quantity 1 1 1 1 No.Cylinders(per Circuit) 2 2 2 — OiI(oz) 50 50 50 54 REFRIGERANT TYPE R-22 Expansion Device Fixed Orific=Metering Device Operating Charge(Ib-oz) Circuit 1 3-6 4-11 5-13 7-8 Circuit 2 — — — — CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fins Rows...Fins/in. 1...17 1...17 1...17 2...17 Total Face Area(sq ft) 7.36 11.39 13.19 10.42 CONDENSER FAN Propeller Type Nominal Cfm 3500 4000 4000 4000 Quantity...Diameter(in.) 1...22.0 1...22.0 1...22.0 1...22.0 Motor Hp...Rpm 1/4...1100 1/4...1100 1/4...1100 /4...1100 Watts Input(Total) 325 325 325 325 EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double-Wavy Fins Rows...Fins/in. 2...15 12...15 3...15 4...15 Total Face Area(sq ft) 4.17 5.5 5.5 5.5 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) Std 1...10x 10 1...10 x10 1...11 x 10 1...10 x 10 Alt 1...10x10 1...10x10 1...10x10 — Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt — Nominal Cfm 1200 1600 2000 2400 Maximum Continuous Bhp Std .34 .75 1.20 2.40 Alt 1.00 1.00 1.30/2.40" — Motor Frame Size Std 48 48 48 56 Alt 48 48 56 — Nominal Rpm High/Low Std 860/800 1075/970 1075/970 — Alt 1620 1620 1725 — Fan Rpm Range Std — — — 1070-1460 Alt 760-1000 835-1185 900-1300 — Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max(in.) Std — — — 2.8/3.8 Alt 1.9/2.9 1.9/2.9 2.4/3.4 — Nominal Motor Shaft Diameter(in.) Std 1/2 1/2 1/2 5/s Alt 1/2 r 1/2 5/8 Fan Pulley Pitch Diameter(in.) Std — — — 4.5 Alt 4.5 4.0 4.5 — Belt,Quantity...Type...Length(in.) Std — — — 1...A...40 Alt 1..,A...34 1...A...34 1...A...39 — Pulley Center Line Distance(in.) Std — — — 14.7-15.5 Alt 10.0-12.4 10.0-12.4 14.7-15.5 — Speed Change per Full Turn of Std — — ! — 80 Movable Pulley Flange(rpm) Alt 48 70 80 — Movable Pulley Maximum Full Turns Std — — — 5 From Closed Position Alt 5 5 5 — Factory Setting Std — — — 3 Alt 3 3 3 — Factory Speed Setting(rpm) Std — — — 1225 Alt 856 975 1060 Fan Shaft Diameter at Pulley(in.) 5/8 5/8 5/8 5/8 LEGEND t ut switch is manually reset by interrupting power to unit or resetting Al — Aluminum thermo . Bhp — Brake Horsepower II Requires an optional or accessory Controls Upgrade Kit. Cu — Copper NOTE:The 580D150 units have a loss-of-charge/low-pressure switch(accessory *Evaporator coil fin materiaVcondenser coil fin material.Contact your local repre- or option)located in the liquid line. sentative for details about coated fins. tWeight of 14-in.roof curb. **Single-phase/three-phase. 5