Report
cfP52--aC-- 660 S& 644sh LCA • • W YATI" FIRE PROTECTION , IN5tCE VD 9095 S.W. Burnham Tigard, OR 97223 JUN 2 2 2015 CITY OF TIGARD BUILDING DIVISION THE DUCK STORE WASHINGTON SQUARE MALL TIGARD, OREGON FIRE PROTECTION EQUIPMENT SUBMITTAL _, tqco Worldwiderntacts Cowww.tyco-fire.com Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General stallation or finish. The tip of the Pro- tective Cap can be used to mark the Description center of the ceiling hole into plaster p board or ceiling tiles by gently push- The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- P "Royal Flush II" Concealed Pendent Pro- tective Cap. When ceiling installation ,. Sprinklers Quick Response (3-mm is complete, the Protective Cap is re- f bulb) and Standard Response (5-mm moved and the Cover Plate/Retainer Assemblyis installed. `'� -""'="!"11 bulb), are decorative sprinklers featur- d,-- „""'�, ing a flat cover plate designed to con- As an option,the Series RFII Standard ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal. ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust ' TY3531 (3-mm Bulb) is UL Listed, Seal is intended for sensitive areas (Certif- Each sprinkler includes a Cover Plate/ C-UL Listed, Approved Retainer Assembly and a Sprinkler/ where it is desirable to prevent air and icate No. G4090007), and NYC Quick Support Cup Assembly. The separa- dust from the area above the ceiling to proved (MEA 353-01-E) as Quick ble, two-piece assembly design pro- pass through the cover plate. Response. vides the following benefits: TY3531 (3-mm Bulb) is FM and NOTICE LPCB Approved (Ref. No. 094a/10) • Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response. and pressure testing of the fire pro- FactoryMutual and LPCB do not tection system prior to installation Sprinklers described herein must be of a suspended ceiling or applica- installed and maintained in compli- approve any concealed sprinklers for quick response. ance with this document and with the tion of the finish coating to a fixed applicable standards of the National • TY3551 (5-mm Bulb) is UL Listed, ceiling. Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and ceiling panels for access to building ties having jurisdiction.Failure to do so NYC Approved (MEA 353-01-E) as service equipment without having may impair the performance of these Standard Response. to first shut down the fire protection devices. system and remove sprinklers. Approvals for Air and Dust Seal The owner is responsible for maintain- • Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de UL and C-UL Listed for use with the vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551). length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure sprinkler drops. with any questions. The Series RFII Sprinklers are shipped Maximum 250 psi (17,3 bar) by UL, C-UL,and NYC with a Disposable Protective Cap.The Sprinkler Protective Cap is temporarily removed Maximum 175 psi (12,1 bar) by FM, during installation and replaced to help Identification VdS,and LPCB protect the sprinkler during ceiling in- Temperature Rating Number (SIN) 155`F(68°C)Sprinkler with IMPORTANT TY3531 — 3 mm bulb 139°F(59-C)Plate Always refer to Technical Data 93° °F C Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200 ( )Sprinkler p inkler with WARNING" that provides cautions 165°F 74°C Plate with respect to handling and instal- Technical Discharge Coefficient lation of sprinkler systems and com- ponents. Improper handling and in- Data p ( ) - stallation can permanently damage Adjustment a sprinkler system or its components Sprinkler Approvals and cause the sprinkler to fail to 1/2 inch(12,7 mm) operate in fire situation or cause it Approvals apply only to the service Finishes toperate afirepremturely. conditions indicated in the Design Cri- teria section. See the Ordering Procedure section. Page 1 of 4 MARCH 2013 TFP181 TFP181 Page 2 of 4 Physical Characteristics 1/2"NPT 4. r SEALING Frame Bronze ASSEMBLY Support Support Cup Chrome _ 0 Plated Steel Guide Pins Stainless Steel FRAME _ +I� Deflector Bronze CAP Compression Screw Brass `\ , A Bulb Glass Kik 1. Cap Bronze or Copper SUPPORT Sealing Assembly Beryllium CUP WITH BULB Nickel w/TEFLON ROLL FORMED . Cover Plate Brass THREADS Retainer Brass Ejection Spring Stainless Steel r, r I1 1 COMPRESSION Design �/ SCREW Criteria PINS(2) �, / ''/ , I GUIDE The TYCO Series RFII 5.6 K-factor, I DEFLECTOR "Royal Flush II" Concealed Pendent1=1 (DROPPED Sprinklers are intended for fire protec- DEFLECTOR7__/ POSITION) tion systems designed in accordance -, tion - r with the standard installation rules rec- ognized by the applicable Listing or SPRINKLER/SUPPORT CUP Approval agency;for example, UL List- ASSEMBLY ing is based on NFPA 13 and VdS Ap- I I proval is based on the CEA 4001. THREAD INTO I RETAINER For more information on LPCB and SUPPORTP UO WITH THREAD Approvals, contact Tyco Fire Pro- MUUN NCTIL O DIMPLES VdS Y MOUNTING . tection Products at the following office: SURFACE IS EJECTION Enschede, Netherlands FLUSH WITH SPRING Telephone:31-53-428-4444 CEILING Fax:31-53-428-3377 The Series RFII Concealed Pendent . `---- 1•72.ummiiiiimmt ---7 Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. SOLDER COVER TABS(3) COVER PLATE/RETAINER PLATE NOTICE ASSEMBLY Do not use the Series RFII in app/ica- FIGURE 1 tions where the air pressure above MODEL RFII CONCEALED SPRINKLER the ceiling is greater than that be- ASSEMBLY low. Down drafts through the Sprin- kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in- sprinkler operation in a fire situation. sufficient adjustment in the Sprinkler The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- Oeration "Royal Flush II" Concealed Pendent kler/Support Cup Assembly. Re-adjust �+ Sprinklers must be installed in accor- the position of the sprinkler fitting to When exposed to heat from a fire, the dance with this section. suit. Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the Retainer at threeopoints, falls away to ter-line Do not install any bulb-type sprinkler if of thenposition perpth the endicular to thee expose the Sprinkler/Support the bulb is cracked or there is a loss Assembly. mounting surface. of liquid from the bulb.With the sprin- Step 2.Remove the Protective Cap. The Deflector — supported by the kler held horizontally, a small air bub- Guide Pins — then drops down to its ble should be present. The diameter Step 3. With pipe thread sealant ap- operational position. of the air bubble is approximately 1/16 plied to the pipe threads, hand-tighten The glass bulb contains a fluid that ex- inch (1,6 mm)for the 155°F (68°C) and the sprinkler into the sprinkler fitting. pands when exposed to heat. When 3/32 inch(2,4 mm)for the 200°F(93°C) Step 4. Wrench-tighten the sprinkler temperature ratings, using only the RFII Sprinkler Wrench. the rated temperature is reached, the (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as glass bulb,activating the sprinkler and should be obtained by applying a min- shown in Figure 3. allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap ft.-lbs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms of torque can distort the sprinkler In- let with consequent leakage or impair- out against the SupportCup. (Refer to Figure 4..) The Protective Cap helps ment of the sprinkler. prevent damage to the Deflector and TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER - DIAMETER HOLE FITTING I DIMENSION C ' SPRINKLER ` J jNM SUPPORT CUP Y t I1II1I ASSEMBLY I ( \ t 1/2"(12,7 mm) THREADED 3 D ADJUSTMENT y III Q.1/FACE '� - OF CEILING, 1 RETAINING RING lv MOUNTING t ^ i 1 SURFACE Al I \ 11 I 1-/ / FIGURE 4 I I 1 DISPOSABLE PROTECTIVE CAP ck:\ A' Arms during ceiling installation and/or =1_r_ 1_ finish.You can also use the Protective I T Cap to locate the center of the clear- 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE ance hole by gently pushing the ceiling (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY the Protective Cap. COVER PLATE COVER PLATE NOTICE -PROFILE DEPTH - DIAMETER As long as the Protective Cap remains • DIMENSION B DIMENSION A in place, the system is considered A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service". B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) Step 6.After the ceiling has been com- pleted with the 2-1/2 inch(63,5 mm)di- ameter clearance hole and in preps- FIGURE2 ration for installing the Cover Plate/ SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis- card the Protective Cap.Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the il�l� FRAME _�� Deflector does not move up and down j ARM (% 741 freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. ' SURT 11A2 ( Step 7. When installing an Air and I - CUP ( Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air111��i ; �� 1■1.4 and Dust Seal, verify the angle of the oor- ���� outside edge of the seal is oriented ac- I■I �� cording to Figure 5. Start the edge of ------- the Retainer in the grooved slot of the 7/8"(23 mm) 0 Air and Dust Seal and continue around SQUARE the retainer until the entire Air and Dust Seal is engaged. ��-`\ Step 8. Screw on the Cover Plate/ ALIGN Retainer Assembly until the Retainer ARROWS WITH 7(/' I 1 \ (shown in Figure 2) or the Air and Dust FRAME ARMS 1_ Seal (shown in Figure 5) contacts the ` l l p1 ceiling. Do not continue to screw on I i i / the Cover Plate/Retainer Assembly ACCEPTS �� so that it.lifts a ceiling panel out of its 0 1/2"SOCKET normal position. If you cannot engage DRIVE the Cover Plate/Retainer Assembly • FIGURE 3 with the Support Cup or you cannot RFII SPRINKLER WRENCH engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Care and SUPPORT -''-- .-- SPRINKLER FACE OF ORIENT CUP CEILING -�� SEAL Maintenance BEVEL AS 1.1 1L. 'T SHOWN The TYCO Series RFII 5.6 K-fac- , PLATE j�COVER ' tor, "Royal Flush II" Concealed Pen- 111 + 1 RETAINER —dent Sprinklers must be maintainedand serviced in accordance with this i�� ASSEMBLY • �� section. _ t,Before closing a fire protection system ' ,,main control valve for maintenance �►)'��� AIR work on the fire protection system that ��• ;!,���i• 7:':---/ AND DUST it controls, obtain permission to shut �.--=--- __—�.-- LIP OF COVER SEAL down the affected fire protection sys- RETAINER PLATE tern from the proper authorities and FIGURE 5 notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) ed by this action. Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Ordering Assembly can delay sprinkler opera- reinstall it or a replacement without re- tion in a fire situation. installing the Cover Plate/Retainer As- Procedure When properly installed, there is a sembly. If a Cover Plate/Retainer As- nominal 3/32 inch (2,4 mm) air gap be- sembly becomes dislodged during Contact your local distributor for tween the lip of the Cover Plate and the service, replace it immediately. availability. When placing an order, ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the full product name. This air gapis necessaryfor proper spection, testing, and maintenance of Sprinkler/Support p p their fire protection system and devic- p pport Cup Assembly operation of the sprinkler. If the ceil- es in compliance with this document, Specify: Series RFII (specify SIN), ing requires repainting after sprinkler as well as with the applicable Stan- K=5.6, "Royal Flush II" Pendent Sprin- installation, ensure that the new paint dards of the National Fire Protection does not seal off any of the air gap. klers (specify) temperature rating and Association(e.g., NFPA 25), in addition (specify)finish, P/N(specify). Do not pull the Cover Plate relative to to the standards of any other authori- the Enclosure.Separation may result. ties having jurisdiction.Contact the in- 155°F(68°C) 200°F(93°C) Sprinklers which are found to be leak- stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200 ing or exhibiting visible signs of corro- sion facturer regarding any questions. TY3551 51-790-1-155 51-790-1-200 must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/ inspected,tested,and maintained by a Retainer Assembly: Automatic sprinklers must never be Automatic , plated, coated, or other- qualified Inspection Service in accor- dance with local requirements and/or Specify: (temperature rating from be- wise altered after leaving the factory, national code. low) Series RFII Concealed Cover Modified sprinklers must be replaced. Plate with (finish), P/N(specify). Sprinklers that have been exposed to 139°F(59°C)(a) 165°F(74°C)(b) corrosive products of combustion, but Grey White have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165 if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165 by wiping the sprinkler with a cloth or Pure White(c) by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165 Care must be exercised to avoid dam- Signal white (RAL9003) 56-792-4-135 56-792-4-165 age to the sprinklers - before, during, Jet Black and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165 aged by dropping, striking, wrench Brushed twist/slippage, or the like, must be re- Chrome 56-792-8-135 56-792-8-165 - placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165 has a cracked bulb or that has lost Custom 56-792-X-135 56-792-X-165 liquid from its bulb. (Ref. Installation (a) For use with 155°F(68°C)sprinklers. Section.) (b) For use with 200°F(93°C)sprinklers. (c) Eastern Hemisphere sales only. Exercise care to avoid damage to sprinklers before, during, and after in- Sprinkler Wrench stallation.Replace sprinklers damaged Specify: RFII Sprinkler Wrench, by dropping, striking, wrench twisting, P/N 56-000-1-075. wrench slipping, or the like. Also, re- place any sprinkler that has a cracked Air and Dust Seal bulb or that has lost liquid from its Specify:Air and Dust Seal, bulb. (Refer to the Installation section.) P/N 56-908-1-001. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. y Dyna-Thread® - M-COAT® Submittal Data Sheet O Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread®—M-Coat®sprinkler pipe represents an engineering NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded Threaded - and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — — 11" 1.408 1.870 2.54 9.50 1.00 ® Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1 11/2" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread®—M-Coat inside diameter is up to 3.6% larger than Sch-40 40 41.6 3.4 4.79 — — giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall 0 c® : thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— .P"aoVeo M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread—MprotectedO American y ead Coat is by a clean,durable mill coating for Made . extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight,Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada, Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR) is a UL Latin America. .(Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed O Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at thisp oint Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working ® Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems.Dyna Thread—M-Coat is approved for all M-Coat is approved for standard hanger spacing(15ft. threaded couplings and welded outlets and is suitable for all pp O.C.),can be used as 9 p 9 earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: I Engineer: Specification Reference: System Type: . Locations: Comments: ^'�III�� Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com (70 • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE &CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 APART OF a,nore ©2013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 /r i Ductile Iron Fittings- Class 300 UL/FM O!JALr;t PLUS c ® Us <D. APPROVED LISTED Fig. 35E 3- 90°Elbow A Size A Packing Weight l � � Part Number in in Inner Master lb it, a II ___iN 1/2 35E 3004 1.13 100 200 140 0.2 1�1� 3/4 35E 3006 1.31 70 0.3 A 1 35E 3010 1.50 40 80 0.5 .' niallt 1-1/4 35E 3012 1.75 25 50 0.8 - 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B , Size part Number A B Packing Weight ' lit.--..„ in in in Inner Master Ib `�,'` = �' Ductile Iron Fittings - Class 300 UL/FM I QUALITY PLUS C ® US 4401/11. APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A Packing Weight 1 in in Inner Master lb I _ 2 335CP3004 1.38 200 400 0.1 /4 35CP3006 1.63 100 200 0.2 I 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35C P3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 111 Size Part Number A Packing Weight p • in in lb 0.3 A 1 x 1/2 1 x 3/4 35RC3010004 1.69 80 160 35RC3010006 1.69 60 120 0.4 0.6 _; 1-1/4 x 3/4 35RC3012006 2.06 40 Inner Master 80 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 ! 1 I I'T A 1-1/4 x 1 35HB3012010 1.19 90 180 0.2-TIT 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 D 2 x 1 35HB3020010 1.38 40 80 0.6 U 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 C 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 I 1 Fig. 35SP3 -Square Head Plug E Size A Packing Weight E in Part Number in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 I 3/4 35SP3006 1.12 350 700 0.1 '1! A 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight F 1'� in Part Number in Inner Master lb � si• ' '� NMI 1350 30102.1920401.0 1-1/4 350 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 `.P"." 2 35U 3020 3.12 6 12 2.4 ux.c 113 SMI'FH-COOPER INTERNATIONAL® • 'POLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com l Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) ®TOLCO Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) c0 us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) LISTED - Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut 44* Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled - • swivel nut design permits hanger adjustment after installation. ] Features: jd . types and protect CPVC plastic pipe from abrasion.Captured design .'. • v • (1/2" (15rnm)thru 2" (50mm)) Flared ed es ease installation for all pipe `- keeps adjusting nut from separating with hanger. Hanger is easily (' \ B installed around pipe. , , A j For hanger with non-captured nut order Fig. 200S. 1 • (21/2" (65mm)thru 8" (200mm))Spring tension on nut holds it securely in . hanger before installation.Adjusting nut is easily removed. f' Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) Fig.200J/2.200-3/4 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and L Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (200mm)). Fg.200 200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) - - am Finish: Pre-Galvanized.Stainless Steele materials will be supplied with (2)hex nuts '~ in place of a knurl nut. Order By: Figure number and pipe size N Designed to meet or exceed requirements of En FM DS 2-0. 4 as I 0) Fig.200 a Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 ` , Part No. in. (mm) in. (mm) in. Unnt) lbs. (kg) •-'411" 200-1/z 1/2" (15) 3/8'-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/a" 185.7) 25/8" 166.7) 12 15.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2' (114.3) 3" 176.3) 15 16.9) 200-21/2 21/2' 165) 3/8"-16 55/8" (142.9) 41/8' (104.1) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 03.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8' (187.3) 51/4" (1333) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) . 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 Ly E.T•N Pipe Hangers Fig. 2 - Adjustable Band Hanger (B-Line B3170) ®TOLCO Fig. 2F- Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line B3170F) c UL us Size Range: LISTED Fig.2 - 21/2" (65mm)thru 6" (150mm)pipe Fig.2F - 21/2" (65mm)thru 6" (150mm)pipe c Material: Pre Galvanized Steelei Function: Recommended for the suspension of non- ✓ insulated pipe or insulated pipe with B3151 shield. ! 1 1 Fig. 2NFPA accomodates the reduced rod schedule of _ the National Fire Pretection Association Pamphlet 13. �\tiD .. ) Approvals: Factory Mutual Engineering Approved. . Underwriters Laboratories Listed.Conforms to Federal Fig.2 J Specification WW-H-171 E&A-A-1192A Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58,Type 10. Standard Finish: Pre-Galvanized Note: Available in Stainless Steel material. Order By: Part number and finish. (411 Fig.2F \ -) -o Fig.2 CD S co Nominal Pipe Size Rod Size B C D Max.Rec.Load Approx Wt./100 cv Part No. in. (mm) A in. (mm) in. (min) in. (mm) lbs. (kN) lbs. (kg) co 2-21/2 21/2" (65) 1/2"-13* 53/4" (146.0) 41/4' (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) 2-3 3" (75) 1/2'-13.X. 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2-31/2 31/z" (90) 1/i'-13* 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6) 2-4 4" (100) 518"-11 .X. 73/8" (187.3) 5" (127.0) 15/8' (41.3) 1000 (4.45) 59 (27.6) 2-5 5" (125) 5/8'-11 ** 9" (228.6) 61/8" (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2-6 6" (150) 3/4"-10** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) Fig.2F Nominal Pipe Size Rod Size B C D Max.Rec.Load Approx Wt./100 Part No. in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 2F-21/2 21/2" (65) 1/2-13* 53/4" (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) 2F-3 3" (751 1/2'-13* 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2F-31/2 31/2" (90) 1/2"-13* 73/8" (187.3) 51/4" (133,3) 21/8" (54.0) 600 (2.67) 52 (23.6) 2F-4 4" (100) 5/8"-11* 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2F-5 5" (125) 5/8"-11** 9" (228.6) 61/8' (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2F-6 6" (150) 3/4"-10** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) * '/e nut is used when requested. ** 1/2 nut is used when requested. All dimensions in charts and on drawings ale in inches.Dimensions shown in pal entheses are it millimeters unless otherwise specified. B-Line by EA•N 22 Fire Protection Solutions Pipe Hangers Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod OTOLCO cC)USSize Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe LISTED Material: Steel, Pre-Galvanized to G90 specifications 441> Function: For fire sprinkler and other general piping purposes. Knurled ^°°a°°IC° swivel nut design permits hanger adjustment after installation. i , Features: • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe - lam. ,_::_:' types and protect CPVC plastic pipe from abrasion.Captured design keeps adjusting nut from separating with hanger. Hanger is easily q installed around pipe. - • (21/2"' (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in �, ' hanger before installation.Adjusting nut is easily removed. ; Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) s ,. "F, Fig.200-1 to 200-2 in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and A Factory Mutual Engineering Approved (3/4" (2omm)thru 8" (2oomm)). (I' Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, . ,1 Type 10. - , / Fig.200-1/2.200-3/4 Maximum Temperature: 650°F(343°C) `, Fig.200-2r/2to 200-8 Finish: Pre-Galvanized.Stainless Steel t'. materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size . 411111, Designed to meet or exceed requirements of FM DS 2-0. Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (min) in. (rnrn) in. (nun) lbs. (kg) m m 200M8-1/2 1/2" (15) M8 31/8" (79.4) 25/8" (66.7) 11 (5.0) ca 200M10-1/2 1/2" (15) M10 31/8" (79.4) 25/8" (66.7) 11 (5.0) a 200M8-3/4 3/4" (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) a 200M10-3/4 3/4" (201 M10 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M8-1 1" (25) M8 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200M10-1 1" (25) M10 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 37/8" (98.4) 27/s" (73.0) 14 (6.4) 200M8-2 2" (50) M8 41/2" (114.3) 3" (76.3) 15 (6.9) 200M10-2 2" {50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 57/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (100) M10 73/8" 1187.3) 5" (127,01 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8" (2572) 63/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ■ B-Line Fire Protection Solutions 23 Ly E.'[•fld Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLco Fig.103) ./.'' \ B3205L - Threaded Rod (right& left hand threads) TL Size Range: 3/a"-16 thru 3"-4 rod SpecifyLength "� Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL 1 Rod is threaded on both ends with right hand threads of the length shown.Also lel�ll� available with left and right hand threads-specify Fig. B3205L when ordering. �� a Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (RN) Lbs. (RN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2' (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2' (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (2624) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 83205-1114 x'L' 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) • B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLL) Fig.100) y� Fig. 99 - All Threaded Rod Cut To Lengthyam . Size Range: 3/8"-16 thru 11/2' 6 rod in 120"(3.05m)lengths or cut to length _ � ��� . Material: Steel ,�41 oto Maximum Temperature: 750°F(399°C) ,, �` -a o Finish: Plain. Contact B-Line for alternative finishes and materials. co m ;00"..."0000000e--------- 'Order By: Part number, rod diameter and finish / a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/a"x 120 99-3/8"x length 16 730 (324) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"X 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Li Pipe Hangers&Supports 236 Revised 4/78/2074 ne by E_T•N Beam Clamps B3031-3/8 - Light Duty Malleable C-Clamp 3/e (19.0) Material: Malleable Iron I C® US Function: Designed for attachinga 3/8"-16 hanger rod to the topor i� (47.6) g 9 tt/2" 1 (47.6) USTEI) bottom flange of a beam or bar joist when setscrew is in the down position (38.1) ti as shown. Approvals: Underwriters Laboratories Listed for up to 4" pipe. Conforms I►� Throat Opening I to Federal Specification WW-H-171 E&A-A-1192A,Type 19 and �' ii-` `F'`, \i ' 1,/16"(17S) Manufacturers Standardization Society ANSI/MSS SP-69&SP-58.Type 19. �i/�\ ''- Finish: Plain or Electro-Galvanized ► 4� Order By: Part number and finish. When retaining strap is required, 77Ei O4 order Fig. 69 separately. See Page 37. Weight: Approx.Wt./100 25 Lbs.(11.3kg) Hanger Rod Set Screw and Design Load: 350 Lbs.(1.55kN) Not Included Locknut Included Note: See page 27 for recommended setscrew torque. B3033 - Wide Jaw Reversible C-Clamp (roLCo Fig.68) Size Range: 3/8"-16 thru 3/4"-10 rod c ----'"?\ o Material: Cast Malleable Steel with hardened cup point set screw O and jam nut Function: For attachment to structural shapes requiring wider throatTB especially under roof with bar joist construction. 1.)forat 8303Open33j1!4"(3t.7)forB3033-/s&VzThis clamp may be used with the set screw in the up or down position. 15/,8"(33.3)for B3033-5/o&3/4 g a- • A Approvals: Underwriters Laboratories Listed(cULus)and Factory (Rod Size) Mutual Engineering Approved (FM).Conforms to Federal Specification �� = Hanger Rod WW-H-171 E Type 19&A-A-1192A,Type 19&23 and Manufacturers 110 ,u � Not lucluded Standardization Society ANSI/MSS SP-69&SP-58,Type 19&23. Set Screw and Finish: Plain. Contact B-Line for alternative finishes and y A materials. :: Locknut Included Order By: Part number, rod size and finish Iii- COW Note: Do not over tighten set screw. LISTED APPROVED Top Flange Attachment ■■ Applications .001 611 .1 iz L IR m Bottom Flange Attachment R N■ - IR L Applications Part Rod Design Load with Setscrew Maximum Iron Approx. No. Size B C D Up Down Pipe Size Per UL Wt./100 A in. (mm) in. (mm) in. (mm) Lbs. (kN) Lbs. (kN) in. (mm) Lbs. (kg) B3033-3/s 3Is"-16 21/4" (57.1) 2' (50.8) 11/8" (28.6) 610 (2.71) 610 (2.71) 4' (100) El (24.5) B3033-1/2 1/2 -13 25/16" (58.7) 23/16" (55.6) 11/4" (31.7) 750 (3.33) 1130 (5.02) 8" (200) ® (23.1) B3033-5/8 5/8 -11 25/8" (66.7) 21/2" (63.5) 13/8" (34.9) 750 (3.33) 1130 (5.02) 8' (200) 70 (31.7) B3033-3/4 3/4"-10 211/16" (68.3) 21/2" (63.5) 17/16" (36.5) 750 (3.33) 1130 (5.02) 10" (250) 98 (44.4) Note: See page 27 for recommended setscrew torque. AU dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. . B-Line Pipe Hangers&Supports 30 by E:T•N Beam Clamps Fig. 69 - Beam Clamp Retaining Strap (B-Line 83367) Size Range: 3/8"-16 thru 3/4"-10 rod Component of State of 4"(101,6mm)thru 16" (406.4mm)lengths C it US California OSHPD Approved Seismic Restraints System • Note: longer lengths are available consult factory LISTED Material: Pre-Galvanized Steel ®TOLCO Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas.Satisfies 111111 requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all • component parts of the assembly.Therefore a locking mechanism of some kind,such as a hex nut or the beveled locking slot of the Fig.69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized 1 Order By: Part number, length(L),and finish. Note: Minimum return on strap is 1"(25.4mm) Hole Dia.D For Use With Length Part No. in. (mm) 69-3/a-L 7/16" B3033-3/8,83034-318,83031-3/8, (30.1) Specify = �!I 65-3/8,65XT-3/8,66-3/8 = Si 69-1/2-L 9/16" (30.1) B3033-1/2,B3034-1/2,65-1/2,66-1/2 Specify 69-5/8-L 11/16" (50.8) B3033-5/8,65-5/8,66-5/8 Specify 69-3/4-L 13/16 (63.5) 83033-3/4 Specify • ■■ Si __ All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line 37 Pipe Hangers&Supports by E.T•N