Report A4 T iS- 0 5)
' Page °1
g � %7k-6( 67 g(t.) �L{✓!�R Ctli/f fQc�
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:49:56
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1868 BEAM A
STATE: OR CODE: IBC 2012
PRODUCT: 3-PLY 1-3/4" X 14" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
FLOOR 40 15 NO 16.000' 0.000' SIDE L/360 L/240
ROOF 30 15 40.000' 6.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 8061 23501 6824 0.146 0.260
ALLOWABLE 8061 46310 17456 0.394 0.591
STRESS INDICES 1.00 0.51 0.39 L/970 L/547
LOAD CASE 1 1 1 1 1
****
THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 440 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 68" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
12.000'
TOTAL SPAN: 12.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 UNIF DEAD ROOF TOP 345.0 PLF 0.000 12.000
+ALL 1 *UNIF DEAD FLOOR SIDE 120.0 PLF 0.000 12.000
+ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 12.000
Page `2
+ALL 1 UNIF WEIGHT BEAM 21.0 PLF 0.000 12.000
+1 1 UNIF LIVE ROOF TOP 517.5 PLF 0.000 12.000
+1 1 *UNIF LIVE FLOOR SIDE 240.0 PLF 0.000 12.000
+2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 12.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 12.000
+3 1 *UNIF LIVE FLOOR SIDE 320.0 PLF 0.000 12.000
+4 1 UNIF LIVE ROOF TOP 690.0 PLF 0.000 12.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 23501 6824 1.25 D+0.75L+0.75Lr
2 10251 2947 0.90 D
3 15848 4840 1.00 D+L
4 22320 6223 1.25 D+Lr
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 8061 8061
2 3516 3516
3 5436 5436
4 7656 7656
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 3516 3516
2 3516 3516
3 3516 3516
4 3516 3516
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 4545 4545
2 0 0
3 1920 1920
4 4140 4140
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
2.047 2.047
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.146 0.394 L/970 0.260 0.591 L/547
2 1 0.000 0.394 0.113 0.591 L/1253 0.113 0.170
3 1 0.062 0.394 L/2295 0.175 0.591 L/811
4 1 0.133 0.394 L/1065 0.247 0.591 L/576
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.51 0.39
2 0.31 0.23
' Page '3
3 0.43 0.35
4 0.48 0.36
SLENDERNESS RATIO = 2.67 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
' Page '1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:45:10
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1868 BEAM B
STATE: OR CODE: IBC 2012
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 15.500' 16.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 5906 16997 5822 0.167 0.231
ALLOWABLE 5906 18187 7897 0.294 0.441
STRESS INDICES 1.00 0.93 0.74 L/634 L/458
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
10" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** CONTACT HANGER MANUFACTURER TO VERIFY ABILITY OF HANGER TO DISTRIBUTE LOAD
*** CONCENTRATED SIDE LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
THIS CONNECTION AND RESTRAINT OF THE TORSION INDUCED BY THE SIDE
LOAD ON THE MEMBER ARE THE RESPONSIBILITY OF THE PROJECT DESIGNER.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 454 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 32" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
9.000'
TOTAL SPAN: 9.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 Xl (FT) X2 (FT)
Page '2
+ALL 1 *UNIF DEAD FLOOR SIDE 240.0 PLF 0.000 9.000
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 9.000
ALL 1 *CONC DEAD FLOOR SIDE 1032.3 LBS 4.500
+1 1 *UNIF LIVE FLOOR SIDE 640.0 PLF 0.000 9.000
1 1 *CONC LIVE FLOOR SIDE 2752.7 LBS 4.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 9.000
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 4.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 16997 5822 1.00 D+L
2 4719 1626 0.90 D
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 5906 5906
2 1650 1650
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1650 1650
2 1650 1650
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 4256 4256
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
2.250 2.250
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 1032.3 4.500 3.000
1 LIVE 2752.7 4.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.167 0.294 L/634 0.231 0.441 L/458
2 1 0.000 0.294 0.064 0.441 L/1645 0.064 0.096
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.93 0.74
2 0.29 0.23
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
' Page '3
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
r
Page.1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:47:37
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1868 BEAM C
STATE: OR CODE: IBC 2012
PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 11.500' 16.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 5416 18282 5367 0.312 0.439
ALLOWABLE 5906 27280 11845 0.454 0.681
STRESS INDICES 0.92 0.67 0.45 L/524 L/372
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 8" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 8" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 454 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 71" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
13.750'
TOTAL SPAN: 13.75 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 210.0 PLF 0.000 13.750
+ALL 1 UNIF WEIGHT BEAM 17.8 PLF 0.000 13.750
+1 1 *UNIF LIVE FLOOR SIDE 560.0 PLF 0.000 13.750
•
Page 2
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 13.750
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 18282 5367 1.00 D+L
2 5287 1552 0.90 D
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 5416 5416
2 1566 1566
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1566 1566
2 1566 1566
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 3850 3850
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
1.500 1.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.312 0.454 L/524 0.439 0.681 L/372
2 1 0.000 0.454 0.127 0.681 L/1288 0.127 0.190
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.67 0.45
2 0.22 0.15
SLENDERNESS RATIO = 2.26 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:54:07
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1868 BEAM D
STATE: OR CODE: IBC 2012
PRODUCT: 3-PLY 1-3/4" X 18" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
FLOOR 40 15 NO 0.000' 13.000' SIDE L/360 L/240
ROOF 30 15 0.000' 0.000' TOP
FLOOR SPAN CARRIED IS CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 11631 49722 10312 0.385 0.653
ALLOWABLE 11631 73854 22444 0.660 0.991
STRESS INDICES 1.00 0.67 0.46 L/617 L/364
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 408 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 39" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
20.000'
TOTAL SPAN: 20.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 XI (FT) X2 (FT)
Page 2
ALL 1 UNIF DEAD ROOF TOP 300.0 PLF 13.500 20.000
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 13.500 20.000
+ALL 1 *UNIF DEAD FLOOR SIDE 97.5 PLF 0.000 20.000
+ALL 1 UNIF WEIGHT BEAM 27.0 PLF 0.000 20.000
ALL 1 *UNIF DEAD FLOOR SIDE 13.6 PLF 0.000 13.500
ALL 1 CONC DEAD ROOF TOP 2146.7 LBS 13.500
1 1 UNIF LIVE ROOF TOP 450.0 PLF 13.500 20.000
+1 1 *UNIF LIVE FLOOR SIDE 195.0 PLF 0.000 20.000
1 1 *UNIF LIVE FLOOR SIDE 27.3 PLF 0.000 13.500
1 1 CONC LIVE ROOF TOP 3220.0 LBS 13.500
2 1 UNIF LIVE ROOF TOP 0.0 PLF 13.500 20.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 20.000
2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 13.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 13.500
+3 1 *UNIF LIVE FLOOR SIDE 260.0 PLF 0.000 20.000
3 1 *UNIF LIVE FLOOR SIDE 36.4 PLF 0.000 13.500
4 1 UNIF LIVE ROOF TOP 600.0 PLF 13.500 20.000
4 1 CONC LIVE ROOF TOP 4293.3 LBS 13.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 49722 10312 1.25 D+0.75L+0.75Lr
2 20491 4314 0.90 D
3 32990 7055 1.00 D+L
4 47206 9570 1.25 D+Lr
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 6203 11631
2 2488 4934
3 5413 7700
4 4517 11098
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2488 4934
2 2488 4934
3 2488 4934
4 2488 4934
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 3716 6697
2 0 0
3 2925 2766
4 2029 6164
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
1.575 2.954
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 2146.7 13.500 3.000
1 LIVE 4293.3 13.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
Page 3
1 1 0.385 0.660 L/617 0.653 0.991 L/364
2 1 0.000 0.660 0.267 0.991 L/889 0.267 0.401
3 1 0.206 0.660 L/1154 0.473 0.991 L/503
4 1 0.310 0.660 L/768 0.577 0.991 L/412
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.67 0.46
2 0.39 0.27
3 0.56 0.39
4 0.64 0.43
SLENDERNESS RATIO = 3.43 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:33:11
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1868 BEAM E
STATE: OR CODE: IBC 2012
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
FLOOR 40 15 NO 0.000' 14.000' SIDE L/360 L/240
ROOF 30 15 7.000' 0.000' TOP
FLOOR SPAN CARRIED IS CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 3628 11384 3386 0.192 0.372
ALLOWABLE 3937 18187 7897 0.429 0.644
STRESS INDICES 0.92 0.63 0.43 L/803 L/415
LOAD CASE 1 3 3 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 385 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 77" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
13.000'
TOTAL SPAN: 13.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 105.0 PLF 0.000 13.000
+ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 13.000
+ALL 1 UNIF DEAD ROOF TOP 52.5 PLF 0.000 13.000
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 13.000
Page.2
+1 1 *UNIF LIVE FLOOR SIDE 210.0 PLF 0.000 13.000
+1 1 UNIF LIVE ROOF TOP 78.8 PLF 0.000 13.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 13.000
+2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 13.000
+3 1 *UNIF LIVE FLOOR SIDE 280.0 PLF 0.000 13.000
+4 1 UNIF LIVE ROOF TOP 105.0 PLF 0.000 13.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 11565 3364 1.25 D+0.75L+0.75Lr
2 5582 1583 0.90 D
3 11384 3386 1.00 D+L
4 7758 2155 1.25 D+Lr
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 3628 3628
2 1751 1751
3 3571 3571
4 2434 2434
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1751 1751
2 1751 1751
3 1751 1751
4 1751 1751
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1877 1877
2 0 0
3 1820 1820
4 683 683
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
1.500 1.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.192 0.429 L/803 0.372 0.644 L/415
2 1 0.000 0.429 0.180 0.644 L/860 0.180 0.269
3 1 0.187 0.429 L/828 0.366 0.644 L/422
4 1 0.070 0.429 L/2207 0.250 0.644 L/619
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.51 0.34
2 0.34 0.22
3 0.63 0.43
Page 3
4 0.34 0.22
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:41:18
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1868 BEAM F
STATE: OR CODE: IBC 2012
PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
FLOOR 40 15 NO 0.000' 0.000' TOP L/360 L/240
ROOF 30 15 18.000' 0.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 9404 21584 8891 0.419 0.764
ALLOWABLE 9404 34100 14807 0.545 0.817
STRESS INDICES 1.00 0.63 0.60 L/468 L/257
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 61" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
16.500'
TOTAL SPAN: 16.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 UNIF DEAD ROOF TOP 135.0 PLF 0.000 16.500
+ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 16.500
+ALL 1 UNIF WEIGHT BEAM 17.8 PLF 0.000 16.500
Page 2
ALL 1 CONC DEAD ROOF TOP 1866.7 LBS 1.500
+1 1 UNIF LIVE ROOF TOP 270.0 PLF 0.000 16.500
1 1 CONC LIVE ROOF TOP 3733.3 LBS 1.500
+2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 16.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 1.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 21584 8891 1.25 D+Lr
2 9790 3540 0.90 D
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 9404 4822
2 3783 2256
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 3783 2256
2 3783 2256
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 5621 2567
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
2.388 1.500
CONCENTRATED LOADS
SPAN TYPE WI (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 1866.7 1.500 3.000
1 LIVE 3733.3 1.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.419 0.545 L/468 0.764 0.817 L/257
2 1 0.000 0.545 0.345 0.817 L/568 0.345 0.517
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.63 0.60
2 0.40 0.33
SLENDERNESS RATIO = 2.26 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
Page 3
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2015.2 12/28/15 15:57:47
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2015.2 EXPIRES ON 3/31/2017. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1668 BEAM H1
STATE: OR CODE: IBC 2012
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 16.500' 1.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 2865 5779 2246 0.085 0.157
ALLOWABLE 3938 11932 6318 0.279 0.419
STRESS INDICES 0.73 0.48 0.36 L/1181 L/640
LOAD CASE 1 3 3 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT.
STRUCTURAL GEOMETRY
SPAN 1
8.500'
TOTAL SPAN: 8.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 UNIF DEAD FLOOR TOP 131.3 PLF 0.000 8.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 8.500
ALL 1 UNIF DEAD ROOF TOP 68.3 PLF 0.000 8.500
+ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 8.500
+1 1 UNIF LIVE FLOOR TOP 262.5 PLF 0.000 8.500
1 1 UNIF LIVE ROOF TOP 102.5 PLF 0.000 8.500
+2 1 CHIP LIVE FLOOR TOP 0.0 PLF 0.000 8.500
Page 2
2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 8.500
+3 1 UNIF LIVE FLOOR TOP 350.0 PLF 0.000 8.500
4 1 UNIF LIVE ROOF TOP 136.7 PLF 0.000 8.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES
CASE MOMENT (LB-FT) SHEAR (LBS) LDF LOAD COMBINATIONS
1 5910 2297 1.25 D+0.75L+0.75Lr
2 2710 1057 0.90 D
3 5779 2246 1.00 D+L
4 3908 1521 1.25 D+Lr
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 2865 2865
2 1314 1314
3 2801 2801
4 1894 1894
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1314 1314
2 1314 1314
3 1314 1314
4 1314 1314
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1551 1551
2 0 0
3 1488 1488
4 581 581
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
1.500 1.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.085 0.279 L/1181 0.157 0.419 L/640
2 1 0.000 0.279 0.072 0.419 L/1395 0.072 0.108
3 1 0.082 0.279 L/1232 0.154 0.419 L/654
4 1 0.032 0.279 L/3155 0.104 0.419 L/967
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.40 0.29
2 0.25 0.19
3 0.48 0.36
4 0.26 0.19
SLENDERNESS RATIO = 2.71 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
Page 3
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.