Loading...
Report Page 2 .303A BEAM 1.dsn • +4 1 UNIF LIVE ROOF TOP 562.5 PLF 0.000 10.000 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 11145 3807 1.00 2 5140 1745 0.90 3 6548 2326 1.00 4 11738 3913 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4750 4750 2 2191 2191 3 2791 2791 4 5003 5003 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 2191 2191 2 2191 2191 3 2191 2191 4 2191 2191 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 2559 2559 2 0 0 3 600 600 4 2813 2813 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.750 3.750 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.109 0.323 L/1063 0.203 0.484 L/573 2 1 0.000 0.323 0.094 0.484 L/1242 0.094 0.140 3 1 0.026 0.323 L/4534 0.119 0.484 L/975 4 1 0.120 0.323 L/967 0.214 0.484 L/544 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.613 0.482 2 0.314 0.246 3 0.360 0.295 4 0.645 0.496 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. r Paces 3 303A BEAM 1.dsn THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Pae 1 'N:\JOBS Stone Bridge\1846\1846 Beams\303A BEAM 2.dsn LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2013.4 04/23/15 13:49:38 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2013.4 EXPIRES ON 3/31/2015. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 303A FLOOR BEAM 2 STATE: OR CODE: IRC PRODUCT: 1-PLY 7" X 11-7/8" LP LVL 2950Fb-2.OE DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 9.500' 0.000' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 7018 28549 6899 0.587 0.834 ALLOWABLE 14438 40491 16071 0.593 0.889 STRESS INDICES 0.486 0.705 0.429 L/364 L/256 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES *** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT. STRUCTURAL GEOMETRY SPAN 1 18.000' TOTAL SPAN: 18.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING WI W2 X1 (FT) X2 (FT) ALL 1 UNIF DEAD FLOOR SIDE 150.0 PLF 10.000 18.000 ALL 1 UNIF DEAD FLOOR SIDE 101.2 PLF 0.000 10.000 +ALL 1 UNIF DEAD FLOOR SIDE 71.3 PLF 0.000 18.000 +ALL 1 UNIF WEIGHT BEAM 23.8 PLF 0.000 18.000 1 1 UNIF LIVE FLOOR SIDE 400.0 PLF 10.000 18.000 1 1 UNIF LIVE FLOOR SIDE 269.8 PLF 0.000 10.000 +1 1 UNIF LIVE FLOOR SIDE 190.0 PLF 0.000 18.000 2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 10.000 18.000 2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 10.000 +2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 18.000 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 28549 6899 1.00 2 8468 2035 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS Page 2 303A BEAM 2.dsn REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 6223 7018 2 1853 2070 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1853 2070 2 1853 2070 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 4370 4948 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 2.500 2.750 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM 1 1 0.587 0.593 L/364 0.834 0.889 L/256 2 1 0.000 0.593 0.247 0.889 L/862 0.247 0.371 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.705 0.429 2 0.232 0.141 SLENDERNESS RATIO = 1.70 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 'N:\JOBS Stone Bridge\1846\1846 Beams\303A BEAM 3.dsn g , LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2013.4 04/23/15 13:50:21 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2013.4 EXPIRES ON 3/31/2015. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 303A FLOOR BEAM 3 STATE: OR CODE: IRC PRODUCT: 3-PLY 1-3/4" X 20" LP LVL 2650Fb-1.9E DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL FLOOR 40 15 NO 0.000' 13.000' SIDE L/360 L/240 ROOF 30 15 11.500' 33.500' TOP FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 12663 61481 10905 0.358 0.647 ALLOWABLE 13781 71852 19950 0.657 0.985 STRESS INDICES 0.919 0.856 0.547 L/660 L/366 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH TWO PLIES WITH 4 ROWS OF 16d (3-1/2") NAILS AT 12" OC. FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD PLY WITH 4 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4") MAY BE USED. *** COMPRESSION EDGE BRACING REQUIRED AT 30" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 20.000' TOTAL SPAN: 20.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD ROOF TOP 337.5 PLF 0.000 20.000 +ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 20.000 +ALL 1 *UNIF DEAD FLOOR SIDE 97.5 PLF 0.000 20.000 +ALL 1 UNIF WEIGHT BEAM 30.0 PLF 0.000 20.000 +1 1 UNIF LIVE ROOF TOP 506.3 PLF 0.000 20.000 +1 1 *UNIF LIVE FLOOR SIDE 195.0 PLF 0.000 20.000 +2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 20.000 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 20.000 Page 2 303A BEAM 3.d§n +3 1 *UNIF LIVE FLOOR SIDE 260.0 PLF 0.000 20.000 +4 1 UNIF LIVE ROOF TOP 675.0 PLF 0.000 20.000 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 61481 10905 1.00 2 27434 4839 0.90 3 40058 7401 1.00 4 60207 10365 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 12663 12663 2 5650 5650 3 8250 8250 4 12400 12400 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 5650 5650 2 5650 5650 3 5650 5650 4 5650 5650 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 7013 7012 2 0 0 3 2600 2600 4 6750 6750 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.358 0.657 L/660 0.647 0.985 L/366 2 1 0.000 0.657 0.289 0.985 L/820 0.289 0.433 3 1 0.133 0.657 L/1781 0.421 0.985 L/561 4 1 0.345 0.657 L/686 0.633 0.985 L/373 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.856 0.547 2 0.424 0.270 3 0.558 0.371 4 0.838 0.520 SLENDERNESS RATIO = 3.81 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR Page 3 303A BEAM 3.dsn • + UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 N:\JOBS Stond Bridge\1846\1846 Beams\303A BEAM 4.dsn LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2013.4 04/23/15 13:50:56 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2013.4 EXPIRES ON 3/31/2015. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 303A FLOOR BEAM 4 STATE: OR CODE: IRC PRODUCT: 1-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL FLOOR 40 15 NO 0.000' 4.000' SIDE L/360 L/240 ROOF 30 15 14.000' 33.500' TOP FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 3915 5882 2608 0.053 0.089 ALLOWABLE 3938 9093 3948 0.208 0.313 STRESS INDICES 0.994 0.647 0.661 L/1422 L/841 LOAD CASE 4 4 4 4 4 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES *** COMPRESSION EDGE BRACING REQUIRED AT 74" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 6.500' TOTAL SPAN: 6.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD ROOF TOP 356.3 PLF 0.000 6.500 +ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500 +ALL 1 UNIF DEAD FLOOR SIDE 30.0 PLF 0.000 6.500 +ALL 1 UNIF WEIGHT BEAM 5.9 PLF 0.000 6.500 +1 1 UNIF LIVE ROOF TOP 534.4 PLF 0.000 6.500 +1 1 UNIF LIVE FLOOR SIDE 60.0 PLF 0.000 6.500 +2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 6.500 +2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 6.500 +3 1 UNIF LIVE FLOOR SIDE 80.0 PLF 0.000 6.500 +4 1 UNIF LIVE ROOF TOP 712.5 PLF 0.000 6.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 5306 2415 1.00 2 2403 1087 0.90 Page 2 303A BEAM 4.dsn 3 2794 1337 1.00 4 5882 2608 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 3531 3531 2 1600 1600 3 1860 1860 4 3915 3915 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1600 1600 2 1600 1600 3 1600 1600 4 1600 1600 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1932 1932 2 0 0 3 260 260 4 2316 2316 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.000 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.044 0.208 L/1704 0.080 0.313 L/932 2 1 0.000 0.208 0.036 0.313 L/2058 0.036 0.055 3 1 0.006 0.208 L/12664 0.042 0.313 L/1771 4 1 0.053 0.208 L/1422 0.089 0.313 L/841 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.583 0.612 2 0.294 0.306 3 0.307 0.339 4 0.647 0.661 SLENDERNESS RATIO = 6.79 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 N:\JOBS Stone' Bridge\1846\1846 Beams\303A GARAGE HDR H1.dsn LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2013.4 04/23/15 13:51:38 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2013.4 EXPIRES ON 3/31/2015. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 303A GARAGE HDR BEAM H1 STATE: OR CODE: IRC PRODUCT: 2-PLY 1-3/4" X 14" LP LVL 2650Fb-1.9E DESIGN CRITERIA FOR ROOF BEAM (UNFACTORED LOADS) LIVE DEAD SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) CARRIED CARRIED SLOPE LOADING LIVE TOTAL 30 15 1.500' 11.500' 0.00 TOP L/240 L/180 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 2529 10196 2159 0.204 0.321 ALLOWABLE 5906 24699 9310 0.816 1.087 STRESS INDICES 0.428 0.413 0.232 L/958 L/609 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT 109" O.C. OR LESS. *** THIS LVL BEAM HAS BEEN DESIGNED TO SUPPORT A 300 LBS CONCENTRATED LOAD ACTING OVER 2.5 X 2.5 FT (6.25 SQ.FT) STRUCTURAL GEOMETRY SPAN 1 16.500' TOTAL SPAN: 16.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD ROOF TOP 97.5 PLF 0.000 16.500 +ALL 1 UNIF WEIGHT BEAM 14.0 PLF 0.000 16.500 +1 1 UNIF LIVE ROOF TOP 195.0 PLF 0.000 16.500 +2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 16.500 Page 2 303A GARAGE HDR H1.dsno 3 1 UNIF LIVE ROOF TOP 48.0 PLF 0.188 2.687 4 1 UNIF LIVE ROOF TOP 48.0 PLF 13.813 16.312 5 1 UNIF LIVE ROOF TOP 48.0 PLF 7.000 9.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 10196 2159 1.00 2 3709 796 0.90 3 3790 906 1.00 4 3790 906 1.00 5 4161 856 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 2529 2529 2 920 920 3 1030 930 4 930 1030 5 980 980 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 920 920 2 920 920 3 920 920 4 920 920 5 920 920 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1609 1609 2 0 0 3 110 10 4 10 110 5 60 60 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 2.250 2.250 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.204 0.816 L/958 0.321 1.087 L/609 2 1 0.000 0.816 0.117 1.087 L/1675 0.117 0.175 3 1 0.003 0.816 L/63758 0.120 1.087 L/1633 4 1 0.003 0.816 L/63758 0.120 1.087 L/1633 5 1 0.012 0.816 L/16046 0.129 1.087 L/1516 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.413 0.232 2 0.167 0.095 3 0.153 0.097 Page 3 303A GARAGE HDR H1.dsn 4 0.153 0.097 5 0.168 0.092 SLENDERNESS RATIO = 4.00 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 2 FLOOR HEADER H1.dsn +ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 8.500 +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 8.500 +1 1 UNIF LIVE ROOF TOP 421.9 PLF 0.000 8.500 +1 1 UNIF LIVE FLOOR TOP 240.0 PLF 0.000 8.500 +2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 8.500 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 8.500 +3 1 UNIF LIVE FLOOR TOP 320.0 PLF 0.000 8.500 +4 1 UNIF LIVE ROOF TOP 562.5 PLF 0.000 8.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LES) LDF 1 10200 3970 1.00 2 4443 1734 0.90 3 72.26 2815 1.00 4 9335 3634 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4984 4984 2 2171 2171 3 3531 3531 4 4561 4561 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 2171 2171 2 2171 2171 3 2171 2171 4 2171 2171 REACTIONS FOR LIVE LOAD CASE BRG#i BRG#2 2813 2813 2 0 0 3 1360 1360 4 2391 2391 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 1.899 1.899 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM 1 0.1.52 0.278 L/659 0.269 0.417 L/372 2 1 0.000 0.278 0.117 0.417 L/854 0.117 0.176 3 1 0.073 0.278 L/1364 0.191 0.417 L/525 4 1 0.129 0.278 L/?76 0.246 0.417 L/407 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH .'L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI Page 3 FLOOR HEADER H1.dsn 1 0.85 0.63 2 0.41 0.30 3 0.61 0.45 4 0.78 0.58 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR L? ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA--PACIFIC CORPORATION. Page 1 N:\JOBS Stone Bridge\1867\1867 BEAMS\FLOOR HEADER H2.dsn LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/15/15 20:30:56 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL: MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW, LLC JOB ID: 1867 FLOOR HEADER H2 STATE: OR CODE: IRC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2650Fb-1.9E DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAST (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL FLOOR 40 15 NO 16.000' 0.000' TOP L/360 L/240 ROOF 30 15 37.500' 10.000' TOP FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 4420 6876 3256 0.060 0.105 ALLOWABLE 4421 11932 6318 0.212 0.318 STRESS INDICES 1.00 0.58 0.52 L/1272 L/724 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . CONNECTION *** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. NOTES *** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT. STRUCTURAL GEOMETRY SPAN 1 6.500' TOTAL SPAN: 6.50 FT LOAD PATTERNS CASE CAS.._ SPAN SHAPE "Ys., SOURCE LOADING G Ml WI X.S. X2 (F7) +AL:. 1 UNIF DEAD ROOF TOP 356.3 REF 0.000 6.500 +ALL 1 UNIF DEAD FLOOR. TOP 120.0 PLF 0.000 6.500 Page 2 FLOOR HEADER H2.dsn +ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500 +ALL I UNIF WEIGHT BEAM 9.5 PLF 0.000 6.500 +1 UNIF LIVE ROOF TOP 534.4 PLF 0.000 6.500 +1 IJNIF LIVE FLOOR TOP 240.0 PLF 0.000 6.500 +2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 6.500 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500 +3 1 UNIF LIVE FLOOR TOP 320.0 PLF 0.000 6.500 +4 1 UNIF LIVE ROOF TOP 712.5 PLF 0.000 6.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 6876 3256 1.00 2 2961 1406 0.90 3 4579 2171 1.00 • 4 6564 3108 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4420 4420 2 1904 1904 3 2944 2944 4 4219 4219 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1904 1904 2 1904 1904 3 1904 1904 4 1904 1904 REACTIONS FOR LIVE LOAD ----------------------- CASE BRG#I BRG#2 1 2517 2517 2 0 0 3 1040 1040 4 2316 2316 MINIMUM BEARING SIZES (IN) ) BRG# 1 BRG# 2 1.684 1.684 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.060 0.212 L/1272 0.105 0.3113 L/724 2 1 0.000 0.212 0.045 0.318 L/16681. 0.045 0.068 3 1 0.025 0.2.12 L/3077 0.070 0.318 L/1087 4 1 0.055 0.212 L/1382 0.101 0.318 L/758 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH , OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE ?4SI VS P • Page 3 FLOOR HEADER H2.dsn 1 0.58 0.52 2 0.28 0.25 3 0.38 0.34 4 0.55 0.49 SLENDERNESS RATIO 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.