Report (33) 16 /1)-011 - 00 / 2_ 53 ? szj ot2)(A. Cameron P. Dutz,Architect, LLC 12365 SW Marion Street Tigard, Oregon 97223 Ph.(503)524-8016 Email: cdutz@frontier.com Date: Mar 4,2011 The Wilde Project 12550 SW 134111 Avenue,Tigard,Oregon 97223 Existing building: See accompanying plan drawing dated 4 March 2011 Code review based on the 2010 Oregon Structural Specialty Code. This code review is intended for use by the building official and architect and shall not be used for construction. Residential Occupancy Group SR-4, Appendix SR; More than 5,but not more than 16 residents. Group SR-4 occupancies shall comply with Group R-4 requirements and supplementary requirements of the SR appendix. Actual number of occupants: 8(based on number of bedrooms on the ground floor) Upper floor contains one room for administration and is not used for guest residents. Building description: Existing building contains 7 bedrooms,2 baths,one laundry room, 1-kitchen, 1-dining room,and 1-family room on the ground floor level. Gross area is 2575 square feet. (2300 sf 1st floor,275 sf 2nd floor) Three of the rooms have direct access to the yard through double French doors. Existing building is conventional wood frame construction,Type V non-rated. Building height and area: Table 503 Maximum area=7000 sq ft and maximum ht.=2 stories. OK Building height increases are not allowed(SR 105). Types of Construction; Table 601 No fire rating requirement for any building elements in type V-B. Fire Resistance Rating for Exterior walls: Table 602 Exterior walls located more than 5 feet and less than 10 feet from property line shall be 1- hour rated construction. North corner of building(kitchen&bedroom) is less than 10 feet from property line. (Measure at right angle from face of wall, Section 702) Section 709 Fire Partitions This section requires that corridors and sleeping unit separations be constructed of V2 hour fire-resistant construction,however,the following exceptions apply: Section 1018.1 states in exception#2 that a fire resistance rating is not required for corridors contained within dwelling units in Group R occupancies. Section 1018.2,exception#2 allows corridor width to be 36 inches minimum if occupant load is less than 50. Section SR106 allows installation of V2 inch"non-rated"gypsum board for sleeping room separation as long as doors are provided with latches,stops,and jambs. Section 903 (see SR 107) Chapter 10 Means of Egress 1003: General Ceiling ht. =7'-6"minimum with the following exceptions: doors: 80 inches; corridor ceilings: 7'-0"; ramps: 80 inches 1004: Occupant Load Residential: 200 sq. ft gross(Table 1004.1.1) Occupant load may be less than calculated value if approved by building official. Calculation: 2575/200= 13 persons. A second exit is available through the family room double French door. 1005: Egress width 10 persons x 0.20(minimum corridor width=36"for less than 50 occupants) See 1018.2 1006: Illumination Means of egress shall be illuminated at all times. (1 foot candle minimum) All components of the egress system shall be illuminated in the event of a power failure. 1008: Doors 4 Minimum clear width= 32"with door in 90 degree open position. Doors may swing inward where the occupant load is less than 50. Doors require lever hardware and ADA thresholds. Hardware height shall be mounted 34"minimum and 48"maximum above the finish floor level. Doors shall securely latch(see SR requirements). Landings of 44" minimum are required at all egress doors. 1009: Stairways No change proposed to existing stairway,however,enclosures under stairways shall be protected with 1-hour fire rated construction. 1010: Ramps Ramp width shall not be less than the required corridor width. (36 inches) This ramp is existing and will not be altered. Surface shall be slip resistant. Handrails required on both sides of ramp when rise exceeds 6 inches. Handrails per 1012 shall be mounted at least 34"above ramp surface and not more than 38 inches. 1014.3: Common path of egress travel shall not exceed 75 feet. 1018.4: Dead end corridors: A 50 ft.maximum dead end corridor is allowed if the building is fully sprinlded. Chapter 11 Accessibility Section 1113 applies to Alterations and is based on a percentage of valuation. Chapter 29 Plumbing Table 29-A (Group R,congregate category) t i • } Water closets: 1 per 8 persons Lavatories: 1 per 12 persons Bathtub or shower: 1 per 8 persons There are a sufficient number of plumbing fixtures to meet this code requirement. Chapter 34 Existing Structures Section 3408 Change of Occupancy,Conformance subject to the approval of the building official. 3408.4 As per our meeting with the building official,there are no requirements to upgrade the building lateral system based on the type of construction and year built. Section SR104.2: Corridors serving as an exit access from individual SR living units serving more than 10 people are required to be 72"wide. However, since this occupancy is less than 10 persons,corridors may be as specified as per chapter 10. Exceptions in the SR section waive the requirements for doors to have fire protection ratings and self- closing devices. All three of the requirements in exception 1 must be met in order to satisfy the code. (1)Each floor shall be attended by staff on a 24 hour basis. (2)Building must be fully sprinldered throughout. (3)Exit access doors must be equipped with positive latching and be an effective bather to limit the transfer of smoke. This code section also allows living and dining rooms to be open to the corridor provided that such areas provide a direct and obvious means of egress to the exit. The occupancy must be less than 50 persons for this to apply. Furthermore,foyers and reception areas shall not be construed as intervening rooms. • Section SR104.3: Point of Safety At least one point of safety is required for SR occupancies. A public way shall be acceptable as a point of safety. Section SR 107 An approved automatic sprinkler system shall be provided throughout buildings with a Group SR fire area in accordance with 903.3. and 903.3.1.2(NFPA 13-R) An approved manual and automatic supervised fire alarm system shall be installed in all Group SR occupancies. Detection is required per Section SR 107.3.1 when an automatic sprinkler system is installed throughout the building and connected to the building fire alarm system. Smoke detectors that comply with UL 268 shall be provided in corridors, sleeping rooms, and spaces open to corridors. Smoke detectors in sleeping rooms shall be monitored by site staff in an approved manner. Section SR 108 There are no controlled egress locks in this building. End, page 3 of 3