Loading...
Plans (50) RECEIVED NOV 13 2012 CITYOFTIGARD Li BUILDING DIVISION 2X4 FRAMING 4 16"O.C. —b u I 111 11 11 11 11 N I1 11 11 1 1 1 II II I . II II 62C-4I 4 _ 2°X12 ° 1 II 11 II II I II II 11 11 11 11 11 11 11 II II II t 16"O.0 \ 10P-o„ SPAN 17'-0"_ SPAN \-- _ / __ – CMU Eo �--_ - = WALL \ FRONT 8'-0" 7'-6" 8'-0" 7'-6" L K+� F1 N 01 -0 1 6V° `iid� l (tom " 177 )11— CITY OF TIGARD N V N Approved...�.....f Et--Y Conditionally Approved f ] o 7 See Letter to:Follow [ ] zo Aged Permit Number:claJ -C 2 " Address: , - '-tom By: sem•. 111/03'Date; I C&,d_e_,, 3/'s L3 c- clo 13'-0" I 18'-0" 12'-6" 18'-0" Approved plans shall be on job site. • 2ND FLOOR 1ST FLOOR OFFICE COPY SCALE: 1/8" = 1' - 0" 14975 SW 74th Ave., Tigard, OR 97224 16'-0" I 17'-0" To Property 150'-0" Line . .11 Ta c 35 Door swing Plenum Length f 1 ► 30'-7" 9 • 0 co u 8'x7. .. 9'-6" 2Y-0" r . 12`-6" 0-418.-0" - - ' lir SCALE: 3/16" = 1'-0" 1ST FLOOR SCALE: 3/16" = 1' - 0" 14975 SW 74th Ave., Tigard, OR 97224 150'_0"co • Q 8 x:8' 8.X LOFT its ' 13._0.. 18'_0" V 2ND FLOOR SCALE: 3/16" = 1' - 0" 14975 SW 74th Ave., Tigard, OR 97224 / A I B I C I D I E 7C Z Each four tube light fixture(standard)requires 0.94 FLA(Full 737 m Load Amps)at 120 V and 0.41 FLA at 277 V. i (12 lights at 120 V=11.28 FLA. 12 lights at 277 V=4.92 FLA.) .7-_-, E Bb. 30'-7" [9323] gli s Each six tube light fixture(optional)requires 1.41 FLA at 120 x CO o z E a,, 9'-0" [2743] W w 0 N � V and 0.62 Vat 277 V. 35" [889] Y ilj Plenum Length a Note: Air exhaust I g5 'i Door swing J $e must be a minimum Agit A 40 Amp 120 V or 277 V circuit is required(by others)to _ _ _ ,=y la connection int L 034" __ of 10ft [3048] away I. l= oQg§ Po Q 1—._--1from air intake. `j a! N Intake Filter,pocket style: 95% average arrestance [0864] w 3111 / 111Illilfihli EXH. � I Igl o 11 o Plenum Filter,51"x 121": 99.9% efficient at removing o m e = z It particles 10 microns and larger Exhaust Filter, GFS WAVE®roll media: 99.67% average arrestance 1111111111111rilij —1--- ® � �' 5 HpInside Length 27' O" [8230] a ; ___ Motor 0 '4 lip I Exhaust (1) l=� '� w Outside Length 30'-7" [9323] C \ 1� ---! �'• ',\ �8 / III (r.i, lig. sr 1 0 Outside Length SB w/Door Swing 34' [10363] 3' O" [914] Clearance il�. �� �j Ea; required for access to O Intake Plenum Length 9' [2743] 1� � � co control panel and motor. ��� �.� � 2'-0" [610] Clearance required . Note: for access to intake filters. 1. Dual skin wall panels are fabricated from 20 gage white precoat sheet ste — 11'-4 3/8" LH SIDE ELEVATION 2. Ductwork is fabricated from 18 gage galvanized steel. m COm03 CO PLAN VIEW N GLOBAL FINISHING SOLUTIONS L.L.C.offers a complete line of automotive spray booths that conform to the requirements of: *NFPA-33 Standard for spray application using -.c, 0 o flammable or combustible materials Eight 4-Tube, Class 1 Product/Frontal door 9'-8" * NFPA-86 Standard for ovens and furnaces 1'-0" [305] Clearance Division 2, Inside-accessible, x 8'-84" [2946 x 2661] 0 0 - • *NFPA-91 Standard for exhaust systems for air required above booth for hip light fixtures. clear opening. conveying of materials _o____ explosion relief system. r� �� _`(1-Window Standard, z 5 *NFPA-101 Life Safety Code _N__ _o____ upgrade Available) rim f 30 * NFPA70 National Electric Code ■ 4 ••g? m c m co *OSHA Safety and Health Standards N N E. * (29CFR 1910, 1910.107) aoa 1 ►�� ill Icz !j zzµoG N 2009 IBC International Building Code ,�— 2 o *2009 IFC International Fire Code 1 Dg q 0 t E a I. + ■ `g This booth has been approved by: . , - t Itl *Ell Equipment Testing Laboratory report o o N . z ��O °# 3049856 Cabin o - . I � u 0 L0f*ETL Equipment Testing Laboratory report - m Dual skin, insulated, o 5#3179888CRT 001 Direct Fired Industrial Air Heater _ iIwall panel construction ■I1111 t m °� 3 IF Conformance to all these requirements is dependent upon the manner in 11 w o 14'-5" [4394] Four 4 Tube, Class 1 Division Personnel door, 2'-8" x 6'-8 3/4" L14' 0" [4267] IA m " which the equipment is installed. The contractor will make certain that all of the electrical wiringand conduit,piping,gas su ply,roof Booth Outside 2, Inside-accessible light [813 x 2051] clear opening. Booth Inside Z °` P penetrations,automatic fire protection systems,and the location of the fixtures in booth side walls. 0 z g z z o 3 o N equipment within the building also conforms to the dted codes and REAR VIEW RH SIDE ELEVATION FRONT ELEVATION other references. M -I Fire suppression system is NOT included with the standard booth but is 0 required by NFPA-33. z to FULL LOAD AMP DRAW -"- I- W RMOTOR FLOW FUEL TYPE Maximum Maximum PROFILE PLATE ENERGY PRODUCTION Maximum INLET TEMP. INLET tU = Z Z ♦- POWER RATE CO NO2 Delta P(inWC) (Btu/h) MANIFOLD PRESSURE RISE PIPE a MOTOR HP QTY 230V,1ph 200V,3ph 220V,3ph 440V,3ph 57W,3ph U W I- 1- (hp) (cfm) CONC. CONC. PRESSURE @ Max.Btu& (°F) N Z 0 = m (ppm) Min. Max. Min. Max. (inWC) cfm (inWC) INTAKE 10 1 50 28.6 27 14 11 (ppm) �j N Lu m t7 LU EXHAUST 5 1 28 15.9 15 7.5 6 LL t Z = Ce NATURALAS0.18 0.46 0.7 0.7 327,300 1,440,000 7.8 11.3 102 1" ADV CURE (OPTIONAL) 1 4 32 14.8 14 7.2 5.6 cc a g < O1 Q • Q 10 12,500 NPT 0 MINIMUM CIRCUIT CAPACITY(AMPS) m pe Z ce X 0 PROPANE 1.90 0.50 0.7 0.7 264,700 1,125,000 2.0 5 80 O INTAKE, EXHAUST ONLY 100 60 55 30 25 E 2 Q o Gas supply required(by others)to gas connection point©. Minimum gas pressure is required at maximum volume consumed. INTAKE, EXHAUST, ADV CURE 140 75 70 40 30 0 0 X 10 hp TEFC intake motor with direct drive,centrifugal fan produces 12,000 cfm. aus G E Z J m Minimum circuit capacity is required(by others)to connection point®. W W W LU nMotors UL recognized PRGYZ. Ci i - (7 N 3 BTE DRAWING NUMBER Glass used in the spray booth meets and exceeds ANSI Z-97.1 standard. 3088468 GA-PFMMP-271409 SHEET � � 1 of 1 A I B I C I D I E ITEM QTY PART NUMBER DESCRIPTION REV 1- op NOTE: 1 1 FCO2120 FLOOR PROFILE-10'DOOR 01 cnm 1.ANCHOR FLOOR OUTER PROFILES TO BUILDING FLOOR.(REF. DIMENSIONS BELOW.) 2 2 FC03024 FLOOR CHANNEL 01 v 2.DOOR FLOOR CHANNEL MAY REQUIRE SHIMMING AND GROUTING IF OPENING IS NOT LEVEL. 3 a FC03162 FLOOR CHANNEL 01 $ T a 3.DOOR FLOOR CHANNEL SHOULD BE ELEVATED ONLY ENOUGH TO ENSURE THAT IT IS LEVEL. 4 1 FC03168 FLOOR CHANNEL 01 ES 7 - _ THE DOOR POSTS AND HEADER PANEL ARE SLOTTED IN ORDER TO MAKE UP THE DIFFERENCE IN HEIGHT BETWEEN DOOR FLOOR CHANNEL AND FLOOR PROFILES. a t 4.CAGE NUTS AND BOLTS ARE NOT REQUIRED WHEN INSTALLING THE BOOTH ON A BASEMENT. cS o0 9 TEK SCREW THE FLOOR OUTER PROFILES TO THE PERIMETER OF THE BASEMENT. DO NOT USE o D ° 3 DOOR FLOOR CHANNEL WHEN INSTALLING THE BOOTH ON A BASEMENT a z d � o IMPORTANT i 8' -_E o N GROUT o cc~3' - ' J MUST BELEVEL AND SQUARE.SHIM AND w �, - _:o THE FLOOR CHANNEL AS REQUIRED. THE AMOUNT OF TIME REQUIRED TO ASSEMBLE THE 6 5 o "r.6 N CABIN WILL DECREASE AND THE FIT AND FINISH OF THE CABIN WILL m os o o i __o 0 IMPROVE WHEN THE FLOOR CHANNELS ARE LEVEL AND SQUARE. ® El o ,, m = 2 o N — M.' 1111,74 1•'m PE .E . m POSITION NOTC © AS SHOWN, \ N 1 i 0 o 8 o • DETAIL A o CM V) A N M V • ' o 0 cnQS 4 hI � H w O cnP oz o ' 116 Z Zp o _ U Z 0 CC - LL J Z ° NOTE: O WX ANCHORS SHOULD BE PLACED IN ALL HOLES _I 032 g 4. IN FRONT AND REAR FLOOR CHANNELS. •3/8"X 2" HILTE CONCRETE ANCORS LU i 3 IMPORTANT -3.000--- —36.000 36.000 36.000 36.000 30.000 36.000 36.000 36.000 36.000 —3.000 i Q N INSERT THE FLOOR ANCHORS ONLY PART NUMBER IN THE LOCATIONS SHOWN ALONG _ 27'-O" AI-PFMMP-271409SBP-3-W3 THE SIDE WALLS OF THE BOOTH. BOOTH INSIDESHEET REV