Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (3)
s « - �- -vUC> '- 1/ W 667k RECEIVED DEC 2 2014 C1TY OFTIGARD MVISION �• • � WYATT' FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 LANDMARK FORD REPAIR STATION 12000 SW 66TH AVENUE PORTLAND, OREGO iZ ,� "�l�- cs c,-, City of Tigard Ap. ove. Plans By Ark& Date r`z `? 4- OFFICE COPY e FIRE PROTECTION EQUIPMENT SUBMITTAL ti1,1is Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-B — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage - Genera► be consulted with respect to the suit- ability of these coatings for any given =r - Description corrosive environment.The effects of ambient temperature,concentration of OP f;,,•i The TYCO Series TY-B, 2.8, 5.6, and chemicals,and gas/chemical velocity, '" < 8.0 K-factor, Upright and Pendent should be considered,as a minimum, • Sprinklers described in this data sheet along with the corrosive nature of the are standard response - standard chemical to which the sprinklers will be ' LAP' coverage,decorative 5 mm glass bulb exposed. type spray sprinklers designed for use An intermediate level version of the "'`=..... in light,ordinary,or extra hazard,corn- Series TY-B Pendent Sprinkler can be mercial occupancies such as banks, obtained by utilizing the Series TY-B hotels, shopping malls, factories, Pendent Sprinkler in combination with - refineries,and chemical plants. the Model S2 Shield. The recessed version of the Series . TY-B Pendent Sprinkler,where appli- NOTICE cable, is intended for use in areas with The Series TY-B Sprinklers described a finished ceiling. It uses a two-piece herein must be installed and maintained �} Style 10(1/2 inch NPT)or Style 40(3/4 in compliance with this document, as inch NPT)Recessed Escutcheon.The well as with the applicable standards /, Recessed Escutcheon provides 1/2 of the National Fire Protection AssociaJill- inch(12,7 mm)of recessed adjustment tion,in addition to the standards of any or up to 3/4 inch (19,1 mm) of total other authorities having jurisdiction. _ f adjustment from the flush pendent Failure to do so may impair the perfor- position.The adjustment provided by mance of these devices. '_ "� the Recessed Escutcheon reduces the °o �' accuracy to which the fixed pipe drops The owner is responsible for maintain- `""—- to the sprinklers must be cut. ing their fire protection system and devices in proper operating condition. Corrosion resistant coatings, where The installing contractor or sprinkler applicable, are utilized to extend the manufacturer should be contacted with life of copper alloy sprinklers beyond any questions. that which would otherwise be obtained when exposed to corrosive atmo- spheres.Although corrosion resistant Sprinkler coated sprinklers have passed the Identification standard corrosion tests of the appli- cable approval agencies, the testing Numbers is not representative of all possible corrosive atmospheres.Consequently, it is recommended that the end user iiiiiiiimmmiPMPIMPIIIiiiiiniilighlamiiiiiiimmomilimigillimiamliaillaT likliellimummilbeiRIMINNtmiliiiii1OFT .. iiiiiiiiim.. . . 1J,....�-.=Ilk,..,vi-t w, i IMPORTANT T Always refer to Technical Data PT Sheet TFP700 for the "INSTALLER !TY4951 Pendent 8.0K, 1/2" NPT WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 FEBRUARY 2014 TFP151 TFP151 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 7 3 - Sealing 6 - D- - IrT�ii 0 -Tr Assemb rushing ill - - -- ------- :0 1 4 - r . gil 7/16" ____ 2-1/4" 01 :, NOMINAL } (57,2 mm �s; _ III I — MAKE-IN I A + 2 *Temperature rating is �r 2-3/16" 1_• 4 indicated on Deflector. Il (55,6 mm) I , mm) fes' 5 ** Pipe thread connections \ ' • i•z�` per ISO 7-1 can be re-g1� ••'`6, ,,'� 6* provided on special 1/2"NPT** f c RENCH request. FLATS UPRIGHT PENDENT CROSS SECTION II FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY/251)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compres - is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Sc - Deflector. special request. PLATE SEATING 4 - Bulb •eflector* SURFACE i Ar 7116" fir-- _ �� 3 ' (11.1 mm) � .�ri�— A 7 = MAKE-INL , , • . mm) 11r� 2 2-3/ -' wor f 4 `-� 2 3/16" i 1-1/2" IP" 1 (55,6 mm) I (38,1 mm) ----- _____-- ----- r5 6* 1/2"NPT** WRENCH STYLE 10 2-7/8"(73,0 mm)DIA. —.- FLATS RECESSED UPRI - PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE TFP151 Page 3 of 8 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE e --.1. 1 ,r, Y-,--v;, 1 / . 1/2" 3 (12,7 mm) '� 0 NOMINAL OPP 2-5/16" =� MAKEIN (58.7 mm) _ r -4111116. 2-1/4" 1-9/16" 4 - i- ---------- (57,2 mm) , . (39,7.1 3/4"NPT** t WREN STYLE 40 2-7/8"(73,0 mm)DIA. 6 J - -- S RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-B UPRIGHT(TY415i)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT,STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* r,1,�-�-��=Ttt 1 ,F Assembly 7/ 3 4 lulb gioi (1 mm) 2-1/4" ) V AMINAL 1 (57,2 mm) 4 ��J 111 MAKE IN *Temperature rating is —�/ I 2-3/16" I 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) -- 11 I S: 5 ** Pipe thread connections \ + I ^14.;==,— 6* per ISO 7-1 can be provided on special 1/2" NPT** f WRENCH request. FLATS UPRIGHT PENDENT ROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE TFP151 Page 4 of 8 SPRINKLER FINISH(See Note 8) K TYPE TEMP. BULB WAX OVER LIQUID NATURAL CHROME POLYES- LEAD WAX LEAD BRASS PLATED TER*** COATED COATED COATED 135'F(57°C) Orange UPRIGHT 155`F(68"C) Red 2 : (TY1151) 175°F(79°C) Yellow 1,2,3 1/2- and NPT (TY; P NT 200'F(93`C) Green N/A III Figure 286°F(141°C) Blue 3.. (182°C) Mauve 1,2 135'F ) Orange UPRIGHT 155`F(68'C) Red (T 31 1) 2,3,5 1,2.3,5 175`F(79`C) PENDENT 1,2,3,4.5,6,7, 1,2,3 (TY3251) 200°F(93"C) Green Figure 2 286'F(141'C) Blue 1",2**,3*°,5** 1**,2**,3**,5** 5.6 1/2- 360`F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68'C) Red PENDENT1,2, (TY3251)* 175°F(79°C) Yellow N/A Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 135'F(57`C) Orange UPRIGHT 155`F(68°C) Red (TY4151) 1,2,3,5 1,2,5 and 175`F(79`C) Yello PENDENT200°F 1,2,3,4,5,6,7 , ' 5 (TY4251) 200'F(93°C) -en 8.0 Figure 3 286°F(141' Blue 1*. 2'* 3`* 5** 1** 2** 5** 3/4" 360'F . °C) Mauve N/A NPT . 'F(57`C) Orange RECES • 155°F(68'C) Red PE. NT1,2,3,4,5 4251)* 175`F(79`C) Yellow N/A Figure 6 200'F(93`C) Green 286°F(141°C) Blue 1,2 C) Gee i1AAiOiiT 155'F(68°C) Red 8.0 ) 1/2- PENDENT 1 �I NNW1,2,3,4,5,6 N/A NPT (TY4951) lempameserh Figure 4 'Wir OW. 0g/we NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) 3. Approved by Factory Mutual Research Corporation(FM) 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) 5. Approved by the City of New York under MEA 354-01-E 6. VdS Approved(For details contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be FM Ap- proved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10(1/2-NPT)or Style 40(3/4"NPT)3/4'Total Adjustment Recessed Escutcheon,as applicable " 150"F(66"C)Maximum Ceiling Temperature Frame and deflector only. TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 2.8 UPRIGHT(TY1151) 1/2" and 175 PSI(12, 1 BAR) N/A NPT PENDENT(TY1251) UPRIGHT(TY3151) and - 5.6 PENDENT(TY3251) 250 PSI(17,2 BAR) 1/2" OR NPT 175 PSI(12,1 BAR) - RECESSED PENDENT (SEE NOTE 1) 4 (TY3251) UPRIGHT(TY4151) and 175 PSI(12,1 BAR) 8.0 PENDENT(TY4251) 3/4" NPT RECESSED PENDENT 175 PSI(12,1 BAR) N/A (TY4251) 8.0 UPRIGHT(TY4851) 1/2'" and 175 PSI(12,1 BAR) NPT PENDENT(TY4951) NOTE 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Physical Characteristics Design Frame Bronze Data Button Brass/Copper Criteria Sealing Assembly Beryllium Nickel w/ TEFLON Approvals Bulb Glass The TYCO Series TY-B, 2.8, 5.6, and UL and C-UL Listed Compression Screw Bronze 8.0 K-factor, Upright and Pendent FM, LPCB, VdS, and NYC Approved Deflector Copper Sprinklers are intended for fire protec- (Refer to Table A for complete approval Bushing(K=2.8) Bronze tion systems designed in accordance information including corrosion resis- with the standard installation rules tant status.) recognized by the applicable Listing Operation or Approval agency (for example, UL Maximum Working Pressure The glass bulb contains a fluid which Listing is based on the requirements Refer to Table B of NFPA 13,and FM Approval is based expands when exposed to heat.When on the requirements of the FM Loss Discharge Coefficient the rated temperature is reached,the Prevention Data Sheets).Only the Style 2) fluid expands sufficiently to shatter the K = 2.8 GPM/psis/2 (40,3 LPM/bars/ 10 or 40 Recessed Escutcheon, as K = 5.6 GPM/psi1/2 (80,6 LPM/bars/2) glass bulb, allowing the sprinkler to applicable, is to be used for recessed K= 8.0 GPM/psi1/2(115,2 LPM/bar112) activate and water to flow. pendent installations. Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table C Recessed Escutcheon:Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass TFP151 Page 6 of 8 2-7/8"DIA. 5/8±1/4" (73.0 mm) 3/4"(19,1 mm) _ (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) WRENCH RECESS FACE OF (57,2 mm) r---MOUNTING (END"A" USED FOR SPRINKLER PLATE ^ 1/2"NPT MODELS) FITTING ..►. / 1/8" �� F (3,2 mm) WRENCH RECESS �� -- (END"B"USED FOR jA j 3/4"NPT MODELS) � FIGURE 7 \ SIF �� } W-TYPE 6 MOUNTING SPRINKLER WRENCH SURFACE -- - -- + CLOSURE SERIES 1-1/4"(31,8 mm) WRENCH TY-B 3/4"(19,1 mm) RECESS FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT ��r� STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT At 2-7/8"DIA. S' 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 14.„,09 (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) PUSH WRENCH FACE OF (57,2 mm) ---..- MOUNTING INTO ENSURE ENGAGEMENT SPRINKLER PLATE WITH SPRINKLER FITTING WRENCHING AREA 1/8" (3,2 mm) FIGURE 8 - SPRINKLER WRENCH I =� 1 \ it? Installation MOUNTING T8.0he TYCO K-factorSeries, TY Upright-B, 2.8and Pendent, 5.6, and SURFACE - - CLOSURE SERIES 1-5/16"(33,3 mm) Sprinklers must be installed in accor- TY-B 13/16"(20,6 mm) dance with this section. FIGURE 6 General Instructions SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY Do not install any bulb type sprinkler if WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT the bulb is cracked or there is a loss of STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT liquid from the bulb.With the sprinkler held horizontally, a small air bubble should be present.The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm).Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-lbs.(13,4 to 26,8 Nm).Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. TFP151 Page 7 of 8 Do not attempt to make-up for insuf- Recessed Pendent Sprinklers Care must be exercised to avoid dam- ficient adjustment in the escutcheon The Series TY-B Recessed Pendent age to the sprinklers before,during,and plate by under-or over-tightening the Sprinklers must be installed in accor- after installation.Sprinklers damaged sprinkler. Readjust the position of the dance with the following instructions. by dropping, striking, wrench twist/ sprinkler fitting to suit. Step A. After installing the Style 10 slippage,or the like,must be replaced. AlUpright and Pendent Sprinklers or 40 Mounting Plate, as applicable, crackedareplace any thatsas lost that has a The Series TY-B Upright and Pendent over the sprinkler threads and with bulb or has liquid from its bulb.(Ref.Installation Section.) Sprinklers must be installed in accor- pipe-thread sealant applied to the pipe dance with the following instructions. threads,hand-tighten the sprinkler into The owner is responsible for the Step 1. Install pendent sprinklers in the sprinkler fitting. inspection,testing,and maintenance of thependentposition; install upright Step B.Tighten the sprinkler into the their compliancefire protection system and devices sprinklerusingonlythe W-Typein as htwith this document, as _ sprinklers in the upright position. p fitting well as with theapplicable standards 7 Recessed Sprinkler Wrench (Figure of the National Fire Protection Associa- Step 2. With pipe-thread sealant 8).With reference to Figure 3 or 4,the • applied to the pipe threads, hand- W Type 7 Recessed Sprinkler Wrench tion (e.g., NFPA 25), in addition to the d tighten the sprinkler into the sprinkler to the sprinkler wrench flats. standards of any other authorities hav- fitting. ing jurisdiction. Contact the installing Step 3.Tighten the sprinkler into the Step C.After the ceiling is installed or contractor or sprinkler manufacturer sprinkler fitting using only the W-Type the finish coat is applied, slide on the regarding any questions. Style 10 or 40 Closure over the Series Automatics sprinklers are recommended 6 Sprinkler Wrench (Figure 7). For TY-B Sprinkler and push the Closure p wax-coated sprinklers, use an 8 or over the Mounting Plate until its flange to be inspected,tested,and maintained 10 inch adjustable Crescent wrench. contacts the ceiling. by a qualified Inspection Service in With reference to Figures 1 through 4, accordance with local requirements apply the W-Type 7 Sprinkler Wrench and/or national codes. or the adjustable Crescent wrench, Care and as applicable is to be applied to the Maintenance wrench flats. When installing wax-coated sprinklers The TYCO Series TY-B, 2.8, 5.6, and with the adjustable Crescent wrench, 8.0 K-factor, Upright and Pendent exercise care to prevent damage to the Sprinklers must be maintained and ser- wax coating on the sprinkler wrench viced in accordance with this section. flats or frame arms and,consequently, exposure of bare metal to the corrosive Before closing a fire protection system environment. Open the jaws of the main control valve for maintenance wrench sufficiently wide to pass over work on the fire protection system the wrench flats without damaging the that it controls, obtain permission to wax coating.Before wrench tightening shut down the affected fire protection the sprinkler, adjust the jaws of the system from the proper authorities wrench to contact only the sprinkler and notify all personnel who may be wrench flats.After wrench tightening affected by this action. the sprinkler, loosen the wrench jaws The owner must assure that the before removing the wrench. sprinklers are not used for hanging After installation, inspect the sprinkler any objects and that the sprinklers are wrench flats and frame arms and only cleaned by means of gently dust- retouch(repair)the wax coating when- ing with a feather duster; otherwise, ever the coating has been damaged non-operation in the event of a fire or and bare metal is exposed. Retouch inadvertent operation may result. • the wax coating on the wrench flats Absence of an escutcheon, which is by gently applying a heated 1/8 inch used to cover a clearance, may delay diameter steel rod to the damaged the time to sprinkler operation in a fire areas of wax, to smooth it back over situation. areas where bare metal is exposed. Sprinklers which are found to be leak- NOTICE ing or exhibiting visible signs of corro- sion must be replaced. • Only retouching of the wax coating Automatic sprinklers must never be applied to the wrench flats and frame p arms is permitted, and the retouching painted, plated, coated, or otherwise is to be performed only at the time of altered after leaving the factory. the initial sprinkler installation. Modified sprinklers must be replaced. Sprinklers that have been exposed to The steel rod should be heated only to corrosive products of combustion, but the point at which it can begin to melt have not operated,should be replaced the wax,and appropriate precautions if they cannot be completely cleaned need to be taken when handling the by wiping the sprinkler with a cloth or heated rod in order to prevent the by brushing it with a soft bristle brush. installer from being burned. TFP151 Page 8 of 8 P/N 57 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 530 2.8K UPRIGHT(1/2'NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2"NPT) TY1251 3 PURE WHITE(RAL9010)' 155 155°F(68°C) POLYESTER 570 5.6K UPRIGHT(1/2"NPT) TY3151 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 571 5.6K PENDENT(1/2"NPT) TY3251 5 JET BLACK(RAL9005)" 200 200°F(93°C) POLYESTER 590 8.0K UPRIGHT(3/4"NPT) TY4151 6 WAX COATED 286 286°F(141°C) a 286°F(141°C)MAX 591 8.0K PENDENT(3/4"NPT) TY4251 7 LEAD COATED 360 360`F(182°C) 560 8.0K UPRIGHT(1/2"NPT) TY4851 8 WAX OVER LEAD 000 OPEN"' 286°F(141`C)MAX 561 8.0K PENDENT(1/2'NPT) TY4951 9 CHROME PLATED Available only for 8.0 K-factor TY4151 and TY4251 for use in Deluge `Eastern Hemisphere sales only Systems.(OPEN "Available in only 8.0K,155°F(68°C) indicates sprinkler or 200°F(93°C);requires lead time to assembly without glass manufacture. bulb,button,and sealing assembly.) TABLE C SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating,P/N(Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with(specify)finish,P/N* `Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. fico TEFLON Is trademark of The DuPont Corporation. Fire Protection Products CO Worldwide Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General The owner is responsible for main- taining their fire protection system and ' • devices in proper operating condition. Description - M The installing contractor or sprinkler s TYCO Series DS-1 Dry-Type Sprinklers, manufacturer should be contacted with t • 5.6K Pendent, Upright,and Horizontal any questions. Sidewall, Standard Response (5 mm Series DS-1 Dry-Type Sprinklers must 1 Bulb) and Standard Coverage, are only be installed in fittings that meet t decorative glass bulb automatic sprin- the requirements of the Design Criteria A klers typically used where: section. • pendent sprinklers are required on e7::-,:::- dry pipe systems that are exposed to Sprinkler freezing temperatures; for example, sprinkler drops from unheated Identification portions buildings • sprinklers and/or a portion of the Numbers (SINS) connecting piping may be exposed to freezing temperatures; for example, • TY3255-Pendent sprinkler drops from wet systems T�"" I 1 _j t F : into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through Technical . ,;! a wall to protect unheated areas of a Data building such as loading docks,over- hangs,and building exteriors Physical Characteristics • sprinklers are used on systems that Approvals Inlet Copper Plug Copper are seasonably drained to avoid UL and C-UL Listed FMA roved Yoke Stainless Steel freezing;for example,vacation resort LPCB Approved: Ref No.094a/11 Casing Galvanized areas CE Certified,Certificate of Conformity: Carbon Steel 0832-CPD-2015 Insert Bronze NOTICE Bulb Seat Stainless Steel NYC Approved under MEA 352-01-E Bulb Glass Series DS-1 Dry Type Sprinklers Refer to Table A. Compression Screw Bronze described herein must be installed Deflector Bronze andmaintainedin compliance with this Maximum Working Pressure Frame Bronze document, as well as with the appli- 175 psi(12,1 bar) Guide Tube Stainless Steel cable standards of the National Fire Water Tube Stainless Steel Protection Association, in addition to Inlet Thread Connections Spring Stainless Steel • - the standards of any other authorities 1 Inch NPT(Standard Order) Sealing Assembly. . . Beryllium Nickel having jurisdiction. Failure to do so ISO 7-R1 w/TEFLON may impair the performance of these Escutcheon Carbon Steel devices. Discharge Coefficient • K=5.6 GPM/psi1/2 IMPORTANT (80,6 LPM/bar'/2) Always refer to Technical Data Temperature Ratings Sheet TFP700 for the "INSTALLER Refer to Table A. WARNING"that provides cautions with respect to handling and instal- Finishes lation of sprinkler systems and Sprinkler: Natural Brass, Chrome components. Improper handling and Plated,Signal White installation can permanently damage Escutcheon: Signal White, Chrome a sprinkler system or its compo- Plated, Brass Plated nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 JUNE 2013 TFP500 TFP500 Page 2 of 8 TY3255 Pendent TY3255 Pendent TY3355 Horizontal Sidewall with top of Deflector-to-Ceiling with Standard with Standard Escutcheon distance of 4 to 12 inches Recessed Escutcheon (Figure 3) (100 to 300 mm) (Figure 4) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon Temperature Bulb Color (Figure 6) (Figure 9) Rating Code TY3155 Upright without Escutcheon (Figure 10) without Escutcheon (Figure 7) SPRINKLER FINISH Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135'F(57'C) Orange 155°F(68'C) Red 1,2,3,5 1,2,5 175`F(79`C) Yellow 1,2,3,4,5 1,2,4,5 1*,2*,3**,4,5 1*,2*,4,5 200°F(93`C) Green 286'F(141°C) Blue 1,2 360-F(182°C) Mauve N/A 1,2,3 1,2 1*,2',5 1*,2' Notes 4. Loss Prevention Certification Board and CE conformity apply to these 1. Listed by Underwriters Laboratories,Inc.(maximum order length of 48 temperature ratings only inches) 5. Approved by the City of New York under MEA 352-01-E 2. Listed by Underwriters Laboratories for use in Canada(maximum order • Light and Ordinary Hazard Occupancies Only length of 48 inches) " Light Hazard Occupancies Only 3. Approved by Factory Mutual Research Corporation (maximum order N/A-Not Available length of 48 inches) TABLE A SERIES DS-1 STANDARD RESPONSE,STANDARD COVERAGE, DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH �� ,0 INLET SEALING 1 ASSEMBLY 1iIi1 WRENCH YOKE RECESS SPRING Eli' e✓', . t11 INLETlil tr. BAND 1r.-, WATER ; WRENCH 4.1.4. Q111.TUBE N i� % CASING FLAT• I' 1 vfi 1I i GUIDE 14°1 TUBE 1 i'� INSERT PUSH WRENCH • - 1 �1 IN TO ENSURE ENGAGEMENT \� 1 BULB WITH SPRINKLER FRAME '�'I, �� SEAT WRENCHING AREA j/11°I FIGURE 2 1/111111 5 mm BULB W-TYPE 7 VENT HOLE 'Ii SPRINKLER WRENCH COMPRESSION DEFLECTOR Se SCREW FIGURE 1 SERIES DS-1 STANDARD RESPONSE DRY-TYPE SPRINKLERS ASSEMBLY TFP500 Page 3 of 8 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN CRITERIA SECTION) CRITERIA SECTION) CRITERIA SECTION) FACE OF FACE OF FACE OF SPRINKLER SPRINKLER SPRINKLER FITTING _I ) FITTING FITTING _hi , ______„ I1 } ORDER LENGTHS: ORDER LENGTHS: , ORDER LENGTHS: 3-1/2" DIA. 2-3/4"to 48" 1- 4" DIA. 3-3/4"to 48" 1/2"to 46" (88,9 mm)y (69,9 to 1219,2 mm) -,5 mm) (95,3 to 1219,2 mm) (12,7 to 1168,4 mm) • IN 1/4"(6,4 mm) IN 1/4"(6,4 mm) -1/4" DIA. IN 1/4"(6,4 mm) 2-1/2" DIA. INCREMENTS I INCREMENTS (57,2 mm) INCREMENTSI (63,5 mm) • 1 / FACE O' 1 .,.".",111 •%� FACE J CEILI FACE OF' W CEI IG ,.111%.1 r. CEILING PI li 0 4-1/4"±1/8" III1 12- 3"DIA. 1 (108,0±3,2 mm) 2-3/16" 1/8" 76,2mm) 1-3/: 1/8" 2 7/8" DIA. It:' ( ± � (55,6 t ',2 mm) (73,0 mm) (34,9 3,2 mm) FIGURE 4 FIGURE 3 PENDENT(TY3255) FIGURE 5 PENDENT(TY3255) WITH STANDARD PENDENT(TY3255) WITH STANDARD ESCUTCHEON RECESSED ESCUTCHEON WITH DEEP ESCUTCHEON SPRINKLER FITTING I (REFER TO DESIGN TOP OF I , CRITERIA SECTION) DEFLECTOR (I I FACE OF SPRINKLER _ FITTING VIA L_ -J ORDER LENGTHS: 5"to 48" (127,0 to 1219,2 mm) ORDER LENGTHS: IN 1/4"(6,4 mm) 5"to 48" INCREMENTS (127.0 to 1219.2 mn IN 1/4"(6,4 mm) INCREMENT ' "CE OF 1 ' •RINKLER FITTING MINIMUM r -3/4"(44,5 mm) I J 1 J DEFLECTOR TO CEILING +I, SPRIN ER FITTING (REF' •TO DESIGN I CR RIA SECTION) FIGURE 6 FIGURE 7 PENDENT(TY3255) UPRIGHT(TY3155) WITHOUT ESCUTCHEON WITHOUT ESCUTCHEON TFP500 Page 4 of 8 ORDER LENGTHS: Operation 2-3/4"to 48"(69.9 to 1219,2 mm) IN 1/4"(6,4 mm)INCREMENTS When TYCO Series DS-1 Dry-Type I __ _ 2-3/8"±1/8" Sprinklers are in service, water is (60,3±3 prevented from entering the assembly FACE OF FACE OF by the Plug with Sealing Assembly — SPRINKLER MOUNTING — (Figure 1)in the Inlet of the Sprinkler. FITTING SURFACE \r The glass bulb contains a fluid that 1 f expands when exposed to heat.When 'llllll4ll�li I■'I, 1 the rated temperature is reached,the 3° DIA• fluid expands sufficiently to shatter +. , (76,2 mm) the glass bulb, and the Bulb Seat is — � 3.5- I released. SPRINKLE- ING 1-3/4"DIA. \ 1 The compressed Spring is then able • REFE' • DESIGN (44,5 mm) to expand and push the Water Tube as ( CENTERLINETERW5/16" well as the Guie Tube outward.This CR IA SECTION) OF WATERWAY (7,9 mm) action simultaneously pulls inward FIGURE 8 on the Yoke, withdrawing the Plug HORIZONTAL SIDEWALL(TY3355) with Sealing Assembly from the Inlet, WITH STANDARD ESCUTCHEON allowing the sprinkler to activate and flow water. ORDER LENGTHS: Design 1/2"to 45-3/4"(12,7 to 1162,1 mm) IN 1/4"(6,4 mm)INCREMENTS I 4-1/4"±1/8" Criteria 2-1/2"DIA. FACE • (108.0±3,2 mm) FACE OF (63,5 mm) M• ' ING TYCO Series DS-1 DryType Sprinklers SPRINKLER , • RFACE are intended for use in fire sprinkler FITTING systems designed in accordance with the standard installation rules �� , recognized by the applicable Listing 11411111Madar. 4,--I . + 3-1/2" DIA. or Approval agency; for example, UL (88,9 mm) Listing is based on NFPA 13 require- 3.5' ments. For more information on �� j LPCB Approval, contact TYCO Fire SPRFITTING GN \ Suppression&Building Products at the ER TO DCENTERLINE 5/16" following office: -ITERIA SECTION) OF WATERWAY (7,9 mm) Kopersteden 1 FIGURE 9 7547 TJ Enschede HORIZONTAL SIDEWALL(TY3355) The Netherlands WITH DEEP ESCUTCHEON Tel:+31-(0)53-428-4444 Fax:+31-(0)53-428-3377 ORDER LENGTHS: Sprinkler Fittings 5-1/2"to 48"(139,7 to 1219,2 mm) - Install 1 Inch NPT Series DS-1 Dry-Type IN 1/4"(6,4 mm)INCREMENTS MINIMUM Sprinklers are to be installed in the 1 2-1/4"(57,2 mm) Inch NPT outlet or run of the following FACE OF -DEFLECTOR TO fittings: —SPRINKLER MOUNTING • malleable or ductile iron threaded SURFACE FITTING tee fittings that meet the dimen- sional requirements of ANSI B16.3 _ \ (Class 150) 'I,III1,IIIIII , • cast iron threaded tee fittings that meet the dimensional requirements `__ / 3.5' 5/16" of ANSI B16.4(Class 125). • S KLER FITTING (7.9 mm) Do not install Series DS-1 Dry-Type EFER TO DESIGN ' CENTERLINE Sprinklers into elbow fittings.The Inlet CRITERIA SECTION) OF WATERWAY of the sprinkler can contact the interior FIGURE 10 of the elbow. HORIZONTTAL SIDEWALL(TY3355) The unused outlet of the threaded tee is WITHOUT ESCUTCHEON plugged as shown in Figure 12. You can also install Series DS-1 Dry-Type Sprinklers in the 1 Inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL TFP500 Page 5 of 8 Temperatures for Heated Areal Ambient Temperature Exposed to Discharge End of 40`F(4°C) 50°F(10°C) 60`F(16°C) Sprinkler Minimum Exposed Barrel Length, Inches(mm)2 40°F(4°C) 0 0 0 30'F(-1°C) 0 0 0 20`F(-TC) 4(100) 0 0 10'F(-12°C) 8(200) 1 (25) 0 0°F(-18°C) 12(305) 3(75) 0 -10°F(-23°C) 14(355) 4(100) 1 (25) • -20'F(-29°C) 14(355) 6(150) 3(75) • -30`F(-34°C) 16(405) 8(200) 4(100) -40'F(-40°C) 18(455) 8(200) 4(100) -50'F(-46`C) 20(510) 10(255) 6(150) -60°F(-51°C) 20(510) 10(255) 6(150) Notes 1. For protected area temperatures that occur between values listed above,use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph(18,6 kph). TABLE B EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS G-FIRE Figure 522. However, the use NOTICE For protected area temperatures of the Figure 730 Tee and Figure 522 for Do not install Series DS-1 Dry-Type between those given above, the this arrangement is limited to wet pipe Sprinklers into any other type fitting minimum recommended length from systems. without first consulting the Technical the face of the fitting to the outside of theP rotected area may be determined The configuration shown in Figure 13 Services Department. Failure to use the byinterpolating between the indicated is only applicable for wet pipe systems appropriate fitting may result in one of values. P glues. where the sprinkler fitting and water- the following: filled pipe above the sprinkler fitting are •Failure of the sprinkler to operate prop- Clearance Space not subject to freezing and where the erly due to formation of ice over the In accordance with Section 8.4.9.2 length of the Dry-Type Sprinkler has the Inlet Plug or binding of the Inlet Plug of the 2010 edition of NFPA 13, when minimum exposure length depicted in connecting an area subject to freezing Figure 11. Refer to the Exposure Length •Insufficient engagement of the Inlet and an area containing a wet pipe section. pipe-threads with consequent leakage sprinkler system,the clearance space For wet pipe system installations of Drainage around the sprinkler barrel of Dry-Type 1 Inch NPT Series DS-1 Dry-Type In accordance with the minimum tempSprineratu must be sealed. Dne to Sprinklers connected to CPVC piping, requirements of the National Fire areas, therp differencesilforbetween use only the following TYCO CPVC Protection Association for dry pipe areas,condensationntinl for the sprinkler and fittings: of in the and 9 sprinkler systems, branch,cross, and subsequent ice build-up is increased. If • 1" x 1" NPT Female Adapter (P/N feed-main piping connected to Dry this condensation is not controlled, ice 80145) Sprinklers and subject to freezing build-up can occur that might damage • temperatures must be pitched for the dry-type sprinkler and/or prevent 1" x 1" x 1" NPT Sprinkler Head proper drainage. proper operation in a fire situation. - • Adapter Tee(P/N 80249). Exposure Length Use of the Model DSB-2 Dry Sprinkler For dry pipe system installations, use When using Dry Sprinklers in wet pipe Boot,described in technical data sheet onay ty he e side reducing teeoutlet olocating f mximu 2-1/2- Sesprinkler systems to protect areas TFP591 and shown in Figures 14 and DS-1chDry-Type S Sprinklers directlyessubject to freezing temperatures, use 15,can provide the recommended seal. P Table B to determine a sprinkler's below the branch line.Otherwise, use appropriate exposed barrel length the configuration shown in Figure 12 to to prevent water from freezing in the assure complete water drainage from connecting pipes due to conduction. above Series DS-1 DryType Sprinklers The exposed barrel length measure- and the branch line. Failure to do so ment must be taken from the face of may result in pipe freezing and water the sprinkler fitting to the surface of the damage. structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. TFP500 Page 6 of 8 RUN • FACE OF O =� r� OUTLET PLUGGED TO WET SIDE SPRINKLER SYSTEM OUTLET FITTING SPRINKLER PLUGGED �ti FITTING HEATED EXPOSURE TO DRY (SEE DESIGN HEATED AREA ilr SYSTEM AREA LENGTH CRITERIA (SEE DESIGN SECTION) DSB-2 CRITERIA AREA SPRINKLER INTENDEDSECTION) SUBJECT DSB-2 DSB-2 INTENDED I FITTING FOR FREEZER TO INTENDED FOR FREEZER (SEE DESIGN - STRUCTURES FREEZING FOR FREEZER STRUCTURES CRITERIA STRUCTURES SECTION) . rib 1 iiip - ,-17- -i I-- 4, i 17 FIGURE 12 FIGURE 13 FIGURE 11 SPRINKLER FITTING SPRINKLER FITTING EXPOSURE LENGTH UNHEATED AREA HEATED AREA STRAP TIES 1-3/4" DIA. • (ENDS ON (44,5 mm) OPPOSING CLEARANCE INSULATED SIDES OF HOLE FREEZER BOOT) ADHESIVE STRUCTURE DSB-2 BOOT DSB-2 / �✓ �— ADHESIVE BOOT %�l% 1-3/4"DIA. T r� (44,5 mm) �'� CLEARANCE 1111- --,z HOLE li-- 1111111111INSULATED % � FREEZER J L STRUCTURE STRAP TIES MIN DS-1 DS-1 (ENDS ON 131 SHOWN WITH OPPOSING SHOWN WITH ,e STANDARD SIDES OF STANDARD ESCUTCHEON BOOT) ESCUTCHEON FIGURE 14 FIGURE 15 MODEL DSB-2 DRY SPRINKLER MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES BOOT WITH SIDEWALL SERIES - DS-1 DRY-TYPE SPRINKLER DS-1 DRY-TYPE SPRINKLER TFP500 Page 7of8 Installation Note: If sprinkler removal becomes Care must be exercised to avoid necessary,remove the sprinkler using damage to the sprinklers - before, TYCO Series DS-1 Dry Type Sprinklers the same wrenching method noted during,and after installation.Sprinklers must be installed in accordance with above.Sprinkler removal is easier when damaged by dropping,striking,wrench this section. a non-hardening sealant was used twist/slippage, or the like, must be and torque guidelines were followed. replaced. Also, replace any sprinkler General Instructions After removal, inspect the sprinkler for that has a cracked bulb or that has lost Series DS-1 Dry-Type Sprinklers must damage. liquid from its bulb. (Ref. Installation only be installed in fittings that meet Step 4. After installing the ceiling or Section.) the requirements of the Design Criteria wall and applying a ceiling finish, slide The owner is responsible for the section. Refer to the Design Criteria on the outer piece of the Escutcheon inspection, testing, and mainte- section for other important require- until it comes in contact with the nance of their fire protection system - ments regarding piping design and ceiling/wall.Do not lift the ceiling panel and devices in compliance with this sealing of the clearance space around out of its normal position. document, as well as with the appli- • the Sprinkler Casing. cable standards of the National Fire Do not install any bulb type sprinkler if When using the Deep Escutcheon, Protection Association (e.g., NFPA the bulb is cracked or there is a loss of hold the outer piece in contact with the 25), in addition to the standards of any liquid from the bulb.With the sprinkler mounting surface(ceiling or wall).Then other authorities having jurisdiction.The held horizontally, a small air bubble rotate the inner piece approximately installing contractor or sprinkler menu- 1/4 turn with respect to the outer piece, facturer should be contacted relative to air bubble is approximately 1/16 inch to hold the Deep Escutcheon firmly any questions. (1,6 mm)for the 135°F(57°C)rating to together. 118 inch(3,2 mm)for the 360°F(182°C)g' Automatic sprinkler systems are recom- ratin Care and mended to be inspected,tested, and maintained by a qualified Inspection A leak-tight 1 Inch NPT sprinkler Maintenance Service in accordance with local joint should be obtained by applying requirements and/or national codes. a minimum-to-maximum torque of TYCO Series DS-1 Dry-Type Sprinklers 20 to 30 ft.-lbs. (26,8 to 40,2 Nm). must be maintained and serviced in Higher levels of torque may distort the accordance with this section. sprinkler Inlet with consequent leakage or impairment of the sprinkler. Before closing a fire protection system Do not attempt to compensate main control valve for maintenance for insufficientottteadjustment in an work on the fire protection system that it controls, obtain permission to Escutcheon Plate by under or over- tightening the Sprinkler.Re-adjust the shutdown the affectedfire protection position of the sprinkler fitting to suit. systems tems from the proper authorities and notify all personnel who may be Step 1. Install pendent sprinklers only affected by this action. in the pendent position; install upright Absence of the outer piece of an sprinklers only in the upright position. escutcheon, which is used to cover a The deflector of a pendent or upright clearance hole, may delay the time to sprinkler is to be parallel to the ceiling, sprinkler operation in a fire situation. Install horizontal sidewall sprinklers in A Vent Hole is provided in the Bulb Seat the horizontal position with their center (Figure 1)to indicate if the Dry Sprinkler line of waterway perpendicular to the is remaining dry. Evidence of leakage back wall and parallel to the ceiling. from the Vent Hole indicatespotential Ensure the word"TOP"on the Deflector leakage past the Inlet seal and e need faces the ceiling. g to remove the sprinkler to determine Step 2. With a non-hardening pipe- the cause of leakage; for example, an thread sealant such as TEFLON applied improper installation or an ice plug. to the Inlet threads, hand-tighten the Close the fire protection ection s stem control - - y sprinkler into the sprinkler fitting. valve and drain the system before Step 3. Wrench-tighten the sprinkler removing the sprinkler. using either: Sprinklers which are found to be • • a pipe wrench on the Inlet Band or leaking or exhibiting visible signs of the Casing (Figure 1). corrosion must be replaced. • the W-Type 7 Sprinkler Wrench on Automatic sprinklers must never be the Wrench Flat(Figure 2). painted, plated, coated, or otherwise altered after leaving the factory. Apply the Wrench Recess of the Modified sprinklers must be replaced. W-Type 7 Sprinkler Wrench to the Sprinklers that have been exposed to Wrench Flat. corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. TFP500 Page 8 of 8 P/N° 60 - XXX - X - XXX I1 I SIN SPRINKLER ESCUTCHEON(t) 96 ` Pendent with Standard TY3255 0 CHROME PLATED SIGNAL WHITE Escutcheon(1"NPT) (Figure 3) (RAL9003) 93 Pendent with Deep TY3255 1 NATURAL BRASS SIGNAL WHITE Escutcheon(1"NPT) (Figure 5) (RAL9003) 97 Pendent with Standard TY3255 2 NATURAL BRASS BRASS PLATED Recessed Escutcheon(1" NPT) (Figure 4) 92 Pendent without TY3255 4 SIGNAL WHITE SIGNAL WHITE Escutcheon(1"NPT) (Figure 6) (RAL9003) (RAL9003) • 9 CHROME PLATED CHROME 94 Sidewall with Standard TY3355 Escutcheon(1"NPT) (Figure 8) 53 Sidewall with Deep TY3355 Escutcheon(1"NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon(1" NPT) (Figure 10) TEMPERATURE ORDER RATING(2) LENGTH(3) 98 Upright without TY3155 Escutcheon(1"NPT) (Figure 7) 0 135°F(57'C) 055 5.50" Notes 1 155°F(68°C) 082 8.25" * Use Prefix "I" for ISO 7-R1 Connection; for example, -60-961-1-180. 2 175°F(79°C) 180 18.00" 1. Escutcheon applies to sprinklers provided with escutcheons. 3 200°F(93°C) 187 18.75" 2. 360`F(182'C)temperature rating applies to non-recessed sprinkler assemblies. 4 286°F(141°C) 372 37.25" 3. Dry-Type Sprinklers are furnished based upon "Order Length"as measured per Figures 3 through 10,as appli- 5 360°F(182°C) 480 48.00" cable, and for each individual sprinkler where it is to be installed.After the measurement is taken, round it to the nearest 1/4 inch increment. TABLE C SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS PART NUMBER SELECTION Ordering • Deflector Style • Part Number from Table C. Part Upright, Pendent,and Horizontal numbers are for 1 Inch NPT standard Procedure Sidewall order sprinklers. Orders for all other • Order Length sprinkler assemblies must be accom- ^ - Contact your local distributor for avail- Dry-Type Sprinklers are furnished panied by a complete description. ability.When placing an order,indicate based upon Order Length as Sprinkler Wrench the full product name, including measured per Figures 3 through 10, Specify W-Type 7 Sprinkler Wrench, description and Part Number(P/N). as applicable.After the measurement P/N 56-850-4-001. Dry Sprinklers is taken, round it to the nearest 1/4 When ordering 5.6 K-Factor Series inch increment. Sprinkler Boot DS-1, Standard Response , Standard • Inlet Connections Specify Model DSB-2 Dry Sprinkler Coverage (5 mm Bulb), Dry-Type 1 Inch NPT or ISO 7-R1 Boot,P/N 63-000-0-002. Automatic Sprinklers, specify the • Temperature Rating This Part Number includes one Boot, following information: two Strap Ties,and 1/3 oz.of Adhesive • SIN • Sprinkler Finish (a sufficient quantity for installing one Pendent TY3255,Upright TY3155,or • Escutcheon Style and Finish, as boot). Horizontal Sidewall TY3355 applicable GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446(Telephone+1-215-362-0700 Copyright 0 2013 Tyco Fire Products,LP. All rights reserved. tI CO TEFLON is trademark of The DuPont Corporation. 'f tqco I Fire & Building Products Technical Services: Tel: (800)381-9312/Fax: (800) 791-5500 Style 65 One-Piece Flush Escutcheon Style 401 Two-Piece Deep Escutcheon 1/2 Inch and 3/4 Inch NPT General WARNINGS The Style 65 and 401 Escutcheons de- - Description scribed herein must be installed and p maintained in compliance with this The Tyco®Style 65 and 401 Escutch- eon document, as well as with the applica- eon Plates illustrated in Figures 1 and 2 ble standards of the National Fire Pro- are designed for use with pendent and tection Association, in addition to the -- horizontal sidewall automatic sprin- standards of any other authorities hav- klers in fire protection systems where ing jurisdiction. Failure to do so may the piping is installed above a ceiling impair the performance of these or behind a wall.They are used to im- devices. STYLE 65 prove the overall appearance of the in- The owner is responsible for maintain- ONE-PIECE ESCUTCHEON stallation by concealing the clearance ing their fire protection system and de- holes required for the connecting pip- vices in proper operating condition. ing and fittings to the sprinkler. The installing contractor or sprinkler The Escutcheon Plates are available manufacturer should be contacted in two styles:Style 65 flush one-piece with any questions. (non-adjustable),and Style 401 deep - two-piece(adjustable). Technical The flush one-piece (non-adjustable) Style 65 Escutcheon Plates(Fig.1)are Data used where the position of the sprin- kler "escutcheon plate seating sur- Approvals face"(relative to the ceiling line or wall) With reference to NFPA 13, listings/ap- / \ x° can be fixed by adjusting the length of provals are not required for metallic the interconnecting piping. escutcheons used for non-recessed The two-piece Style 401 Escutcheon applications. Plates(Fig.2)are used where it is nec- Finishes essary to position the sprinkler away Chrome,White,or Brass STYLE 401 from the ceiling/wall surface so that Material TWO-PIECE ESCUTCHEON spray will not be adversely affected by Carbon Steel protruding obstructions such as light fixtures and HVAC diffusers. The adjustment provided by the Style 401 Escutcheon Plates reduces the ac- curacy to which the length of the fixed pipe drops or horizontal pipe runs to the sprinklers must be cut, and it pro- . vides additional flexibility in the inter- connecting pipe. The separable, two-piece design of the Style 401 allows installation of the sprinklers and pressure testing of the fire protection system/evaluation of leak tightness prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit the removal of suspended ceiling panels, for access to building service equipment, without having to first shut down the fire protection sys- tem and remove sprinklers. Page 1 of 4 DECEMBER, 2007 TFP777 Page 2 of 4 TFP777 3-1/2"DIA. 2-13/16"DIA. (89,0 mm) (71,4 mm) 2-1/2"DIA. 2 DIA. -' (63,5 mm) f (50,8 mm) f i ii 2-1/4"DIA. (57,2 mm) f CEILING CEILING SURFACE SURFACE i // 1I1 AIII Illfil ' 1 %. .// 1 1 v SKIRT * 17- 2-7/8"MAX. . '�' 1 (73,0 mm) I I FRICTION MIN.1-7/8" I l`��,J 1/2" FIT (47,6 mm) �1 1/2"OR _ii,... (12,7 mm) 3/4"NPT CUP* ��. 1 \ t OPENING ESCUTCHEON 1/2"OR gI r SHOWN WITH PLATE SEATING 3/4"NPT _A SERIES TY-FRB SURFACE OPENING ESCUTCHEON 5.6 K-FACTOR PLATE SEATING PENDENT SPRINKLER SHOWN WITH SERIES TY FRB SURFACE FOR REFERENCE 5.6 K-FACTOR PENDENT SPRINKLER *ORDERED FOR REFERENCE SEPARATELY FIGURE 1 FIGURE 2 STYLE 65 ONE-PIECE STYLE 401 TWO-PIECE DEEP FLUSH ESCUTCHEON ADJUSTABLE ESCUTCHEON TFP777 Page 3 of 4 Installation Step 4. Using the appropriate sprin- kler wrench,tighten the sprinkler into NOTES the fitting. A leak tight 1/2 inch NPT sprinkler joint Step 5.After a suspended ceiling has should be obtained with a torque of 7 been installed or the finish coat has to 14 ft.lbs. and 10 to 20 ft.lbs. should been applied to a wall or fixed ceil- be sufficient for a 3/4 inch NPT sprin- ing (as appropriate), align the detents kler.Higher levels of torque may distort in the skirt over those in the cup and the sprinkler orifice seat with conse- then slide the cup over the skirt until quent leakage. it comes in contact with the mount- ing surface.Do not push the skirt such Do not attempt to make-up for insuf- that it will lift a ceiling tile out of its nor- ' ficient adjustment in an Escutcheon mal position. Plate by under- or over-tightening the Holding the skirt in contact with the • sprinkler. Readjust the position of the mounting surface, rotate the skirt ap- sprinkler fitting to suit. proximately 1/8-turn in relation to the Style 65 cup creating a friction fit between the The pipe connected to the sprinkler skirt detents and the cup wall, to hold fitting must be cut so that the "es- the Escutcheon Plate firmly together. cutcheon plate seating surface" is at the proper nominal distance in front Care and of the wall or below the ceiling. Man- ufacturing variations in the take-out of Maintenance the fittings as well as the make-in of the sprinklers (as permitted by ANSI The following inspection procedure B1.20.1) may require that trial cuts of must be performed as indicated, in the connecting pipe be made. addition to any specific requirements Proceed with the assembly as follows: of the NFPA.Any impairments must be Step 1. Insert the threaded end of immediately corrected. the sprinkler through the Escutcheon The owner is responsible for the in- Plate. spection, testing, and maintenance of Step 2. Apply pipe thread seal- their fire protection system and devic- ant sparingly to the sprinkler threads es in compliance with this document, only. Use of a non-hardening type of as well as with the applicable sten- Teflon based pipe thread sealant is dards of the National Fire Protection recommended. Association(e.g.,NFPA 25),in addition Step 3.Hand tighten the sprinkler with to the standards of any authority hay- the attached Escutcheon Plate into the ing jurisdiction.The installing contrac- sprinkler fitting. tor or product manufacturer should be Step 4. Using the appropriate sprin- contacted relative to any questions. kler wrench, tighten the sprinkler into It is recommended that automatic sprin- the fitting. kler systems be inspected, tested, and Style 401 maintained by a qualified Inspection She pipe connected to the sprinkler fit Service in accordance with local re- ting must be cut so that the"escutch- eon plate seating surface" is at the After placing a fire protection system proper nominal distance in front of the in service, notify the proper authorities wall or below the ceiling. and advise those responsible for mon- Proceed with the assembly as follows: itoring proprietary and/or central sta- Step 1. Separate the two pieces of tion alarms. the Escutcheon Plate and screw the cup onto the sprinkler until the plate is engaged onto the last thread of the sprinkler. Step 2.Apply a brush-on pipe thread sealant sparingly to the sprinkler threads only. Use of a non-hardening type of Teflon based pipe thread seal- ant is recommended. Step 3.Hand tighten the sprinkler with the attached inner plate into the sprin- kler fitting. Page 4 of 4 TFP777 Limited Ordering Warranty Procedure Products manufactured by Tyco Fire When placing an order,indicate the full & Building Products (TFBP) are war- product name.Contact your local dis- ranted solely to the original Buyer for tributor for availability. ten(10)years against defects in mate- Style 65 rial and workmanship when paid for Specify:Style 65 Flush One-Piece Es- and properly installed and maintained cutcheon with (1/2 or 3/4) NPT Open- under normal use and service. This warranty will expire ten(10)years from ing and(Chrome,White,or Brass)Fin date of shipment by TFBP.No warran- ish,P/N(specify). ty is given for products or components Style 65 One-Piece Escutcheon manufactured by companies not af- 1/2"Chrome P/N 1153 filiated by ownership with TFBP or for 3/4"Chrome P/N 1152 products and components which have 1/2"White P/N 1174 been subject to misuse, improper in- 3/a"wnite P/N 1175 • stallation,corrosion,or which have not 1/2"Brass P/N 1150 been installed,maintained,modified or 3/4"Brass P/N 1184 repaired in accordance with applicable Style 401 Cup* Standards of the National Fire Protec- Specify:Style 401 Cup with(1/2 or 3/4) tion Association,and/or the standards NPT Opening and (Chrome, White, or of any other Authorities Having Juris- Brass)Finish,P/N (specify). diction. Materials found by TFBP to be defective shall be either repaired or re- Style 401 Cup placed, at TFBP's sole option. TFBP 1/2"Cup.Chrome P/N 1192 neither assumes, nor authorizes any 3/4"Cup.Chrome P/N 1193 person to assume for it, any other ob- 1/2"Cup.White P/N 1196 ligation in connection with the sale of 3/4"Cup.White P/N 1197 products or parts of products. TFBP 1/2"Cup.Brass P/N 1194 shall not be responsible for sprinkler 3/4"Cup.Brass P/N 1195 system design errors or inaccurate or Style 401 Skirt* incomplete information supplied by Specify:Style 401 Skirt with(Chrome, Buyer or Buyer's representatives. White,or Brass) Finish, P/N(specify). In no event shall TFBP be liable, in Style 401 Skirt contract, tort, strict liability or under Chrome P/N 1198 any other legal theory, for incidental, White P/N 1200 indirect,special or consequential dam- Brass P/N 1199 ages, including but not limited to labor *The Cup and Skirt are ordered sepa- charges, regardless of whether TFBP rately for the Style 401 Escutcheon. was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- . press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products,materi- als or components, whether the claim is made in contract,tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale Pennsylvania 19446 Dyna-Flow® - M-COAT® Submittal Data Sheet High Strength Steel Pipe Dyna-Flow-M-COAT Specifications • Dyna-Flow' -hi-Coat`pipe is the"original"high-strength light::all sprinkler pipe. NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR Dyna-Flow-M-Coat has outstanding hydraulic capabilities and is recognized as the Irrmm In;mm ' Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded most popular alternative to Schedule-10 pipe.Lightweight,easy to cut and easy to 1" 1.191 0.830 1.31 2.41 • handle for installation.Dyna-Flow-M-Coat is a valuable addition to any fire 25 30.3 1.2 1.95 - protection system. 11/4" 1.536 1.059 1.87 1.55 32 39.0 1.6 2.78 - • ® Additional Benefits 11/2" 1.728 1.667 2.71 3.44 Lightweight and easy to install,resulting in more efficient use of your freight and labor 40 43.9 2.5 4.03 - dollars,Provides stability needed to comply with standard hanger spacing(15 ft O.C.) • 2" 2.203 2.104 3.79 2.78 per 11FPA.Available in standard lengths for your convenience,or can be ordered in 50 56.0 3.1 5.64 custom lengths lengths upon approval.Fast cutting and welding,as well as easy roll grooving • 21/2" 2.703 2.564 5.10 1.60 and end preparation.Available in Factory roll grooved form for quicker shop turnaround. 65 68.7 3.8 7.59 - Clean,durable mill coating provides longer"shelf life"and acts as an excellent primer I 3" 3.314 3.387 7.18 1.48 for custom paint applications. 75 84.2 5.0 10.69 - • 4" 4.310 4.473 10.86 1.00 O Superior Hydraulics With an inside diameter of up to 11%larger than Schedule 40 and up to 7%larger COc® 40110 than Schedulel0,Dyna-Flow-M-Coat pipe hydraulics are exceptional.Larger I.D.s APPROVED enable Dyna-Flow-M-Coat,and related components,to be down-sized within the system,thus increasing the potential for job cost savings.For complete Hazen-Williams ay Specifications & Approvals charts,refer to"Dyna-Flow Hydraulic Data Tables." Dyna-Flow-M-Coat pipe is manufactured to meet ASTM A 795, Coatings & Fabrication Type E Grade A,and are in compliance with NFPA-13 and NFPA-14. Dyna-Flow-M-Coat products are coated externally with an environmentally approved All sizes of Dyna Flow are UL Listed,FM Approved and ULC Listed. and specially formulated modified-acrylic or water-based coating.This durable,exterior Dyna-Flow-M-Coat is UL/ULC Listed for use with roll grooved, black coating is paintable and acts as an excellent primer that is resistant to weathering plain-end couplings,arid welded joints for wet,dry,pre-action and and U.V.degradation fiom outdoor storage.Metallurgical properties provide excellent deluge systems.It is FM Approved for roll grooved,plain-ended,and fabrication characteristics for end prep finishes,welding and roll grooving.No special welded joints for wet systems.Refer to appropriate documentation process or equipment is needed for fabrication and installation. for up-to-date listing and approval information. The internal surface of all black Fire Sprinkler pipe up to 4.5000"in diameter shall be - coated with Allied Tube&Conduit's"Id-Coat"ID Coating. O American Made Manufactured at one of 3 U.S.Facilities and is available through distributors in rite USA, Canada,Mexico,and Latin America. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 9" Customer Service:(800)882-5543 Fax: (800)659-7730 www.alliedtube-sprinkler,com ciIlieci • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 A PART OF 4\44t1:.:9!: ©2012©2012 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1207 Victaulic® FirelockTM Rigid Coupling htaui,cr Style 009N 10.64 Patented 1.0 CERTIFICATION/LISTINGS ©� F� ILPCBI Vds C104-1a/36 • 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange enamel (North America, Asia Pacific) Red enamel (Europe) Hot dipped galvanized Gasket: (specify choice1) Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest V I it ,,t r'S:I.• ;ui 1-for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. System No. Location r Spec Section Paragraph Submitted By Date Approved Date victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. 1 \ictaulic victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB Sch.5 Sch.10 Sch.40 Sch.5 Sch.10 Sch.40 inches psi psi psi psi psi psi psi psi mm • kPa kPa kPa kPa kPa kPa kPa kPa i 11/4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 • 2500 2500 11/2 i 232 365 365 175 363 363 363 r 363 40 1600 2517 2517 i 1205 2502 2502 2500 2500 • 2 363 i 365 365 175 363 I 363 363 i 363 • 50 i 2502 i 2517 2517 I 1205 2502 i 2502 2500 2500 • •• 2'/z N/A • 365 365 175 i 363 363 363 363 65 2517 2517 I 1205 2502 i 2502 2500 • 2500 ' • • • 76.1 mm N/A 251733 N/A N/A 25024 N/A i 363 2500 563 00 3 N/A 365 365 175 363 363 363 363 • 80 2517 i 2517 i 1205 2502 i 2502 j 2500 i 2500 • 4 365 365 175 363 363 363 363 100 I N/A 2517 2517 1205 i 2502 i 2502 2500 2500 • 108.0mm 1 N/A N/A N/A 175 363 363 N/A N/A 1205 2502 2502 5 290 • 365 363 363 232 125 ' N/A 2000 2517 N/A 2502 2502 1600 N/A 133 0 mm N/A N/A 4 N/A N/A 2502 4 N/A N/A N/A 139.7 mm N/A 290 ss N/A N/A 363 s N/A 232 N/A 2000 2502 1600 159 0 mm N/A N/A I N/A I N/A 363^ N/A N/A i N/A 2502 4 2906 363 4 165.1 mm N/A2000 a N/A N/A 2502' N/A N/A i N/A 6 290 365 363 • 363 232 150 N/A 2000 2517 i N/A 2502 2502 1600 N/A t 2502363 4^ 8 N/A 290 • 365 3632502 363— _ 232 N/A 216.0mm N/A N/A N/A N/A N/A N/A • 200 2000 2517 ii N/A 2502 1600 2 Listed/Approved for wet and dry pipe systems(>—40'F/-40`C)for continuous use in freezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic I I./LSI ii,'vi.,iiu.,I I-CCl(I1 In/—for details concerning when supplemental lubrication Is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus • FM cULus FM inches psi psi inches psi psi inches psi psi kPa kPa kPa • kPa kPa kPa BLT 1'/4-2 • 300 365 EZT 1/<_2 300 365 MT 11/4-2 300 365 2068 2517 2068 2517 2068 2517 DF 1'/4-4 300 365 FF 11/4-4 300 365 MLT 1'/r2 N/A 365 2068 2517 2068 2517 2517 DT 1'/4-2 • 300 365 FLF 1'/4 4 N/A 365 ST 13/4-2 N/A 365 • 2068 2517 2517 2517 EF 1'/4-4 1206 1206 FLT 1'/4-2 N/A 2175 175 56 7 /4 STF 1' -4 N/A 2567 6L 300 1 365365 13/4-2 • 068 • 2517 FLTL 1'/4-2 N/A 2517 365 TF 2'/4-4 N/A i 2517 ET40 1 Y4-2 300 365 GL 1'/4-2 300 365 WLS 1'/4 2 300 365 2068 2517 2068 2517 2068 2517 EZF • 3_4 300 - 365 MF 1'/4-4 300 365 WST 1'/4 2 N/A 365 2068 2517 2068 2517 2517 j 300 365 XL 1/4-2 2068 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • ELT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • 10.64 7072 Rev G Updated 10/2014 ©2014 Vlctaulic Company.All rights reserved. victaulic.com 3 ✓ctauhc° victaulic.com I Couplings I FireLock I Rigid I Style O09N I Publication 10.64 5.0 DIMENSIONS Style O09N ,.,c--\..., 7Z ".*L EE ITA SI a il Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) - Dimensions Actual . Maximum Maximum Allow. Pre-assembled Approx. • Nominal Outside Working End ' Pipe End Bolt/Nut 9 (Push On Condition) Joint Assembled Weight - Size Diameter I Pressure 7 Load 7 Separations Size X Y X Y 2 Each inches inches psi lbs. inches inches inches inches inches inches inches lbs. ' mm i mm kPa N mm No. mm mm : mm mm mm mm kg i 11/4 , 1,660 365 790 0.10 %x 2 I 3.13 5.00 2.75 i 5.00 2.00 i 1.4 32 42.4 2517 3514 2.54 2i M10 x2 ; 79 127 70 i 127 ', 51 , 0.6 i 11/2 i 1.900 365 1035 0.10 2 i %x 2 I 338 5.13 3.00 5.13 2.00 ! 1.5 l 40 I 483 2517 4604 2.54 • M10 x 2 I 86 130 76 13051 0.7 2 2.375 365 1616 0.12 ! %x2'1 ' 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517 7193 3.05 M10 i 102 143 89 143 51 0.9 2% 2.875 365 2370 0.12 2 i %x 21/2 i 4.50 6.13 4.00 6.13 2.00 I 2.1 65 73.0 2517 10542 ! 3.05 M10 x21/2! 114 156 102 i 156 51 1.0 76.1 mm 3.000 365 2580 0.12 ij x 2'k 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 2 'M10 x 2'h 118 152 105 156 51 1.0 ' I s 3 3500 ! 365 3512 0.12 I3/4)(21/2 I 5.13 1 6.75 463 6.75 2.00 23 80 ' 88.9 I 2517 15622 ! 3.05 2 M10x21/2' 130 171 117 171 51 1.0 • 4 4.500 365 5805 ! 0.17 12 34 x 2'% I 6.00 7.88 5.63 7.50 2.13 2.9 100 114.3 2517 25822 I 4.32 M10 x 21/2 152 200 143 i 191 54 1.3 108.0 mm 4.250 365 5175 0.17 2 i %x 2'% 5.63 I 7.38 5.38 ! 7.38 2.13 3.1 108.0 2517 23020 •! victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 6.0 REFERENCE MATERIALS • Pub!c et cn O .L.= :Seal Selection Guide -u���'•tiu.i�I Installation Instructions FireLock EZ° Rigid Coupling • • • • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of Th Is product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,In accordance with Industry to be installed in accordance with current Victaulic installation/assembly instructions, • standards and project specifications,as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safely,and warning instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice.or opinion from any Victaulic employee,shall be deemed to Installation alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions l-or Reference should always be made to the ,. of sale,Installation guide,or this disclaimer. Y -I -> �.{-- -L[ .� I ,Il.l .i r .r I for the product you are installing.Handbooks are Included with Intellectual Property Rights each shipment of Victaulic products,providing complete installation and assembly data. No statement contained herein concerning a possible or suggested use of any material, and are available in PDF format on our website at wwwylctaullc.com. product,service,or design is Intended,or should be constructed,to grant any license Warranty under any patentor other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design,or as a recommendation for the use of such material,product,service,or design in the infringement of any patent or other Intellectual Trademarks property right.The terms"Patented'or"Patent Pending"refer to design or utility patents Victaulic,FireLock EZ.,Flush-Seal.,and Installation-Readyre are trademarks or or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or Its affiliated entitles,in the U.S.and/ countries. or other countries, • • 10.64 7072 Rev G Updated 10/2014 *2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic Victaulic® Standard Flexible Coupling ✓�tauIic° Style 77 06.04 Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publicatron 0 I 0II 17.09 for pressure ratings and end loads.When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further 1 information regarding grooving stainless steel pipe, refer to publication 17.01. For 14—247350—600 mm flexible roll groove systems, • a Victaulic recommends Style W77 AGS couplings. For /4—12"/20—300 mm sizes 14—24°/350—600 mm sizes more information, request submittal public_;tion 20.03. Approvals/Listings a : q LPCB ® ® vds Z" 'c �,r t t 104-la/04 • Victaulic RX roll sets must be used when grooving See Victaulic I I;.,-o, U !,I for details light-wall/thin-wall stainless steel pipe for use with See Victaulic. Ll.., 0U:.0�for potable water approvals if applicable. Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving Product Description light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or Style 77 couplings are designed with cross-ribbed property damage. construction to provide a component for pressure piping systems.The coupling is offered in a two piece housing design from 3/4—24'/20—600 mm sizes for pressures up NOTICE to 1000 psi/6900 kPa. • Victaulic RX grooving rolls must be ordered All sizes are provided with plated bolts and nuts. separately.They are identified by a silver color and Galvanized and stainless steel housings are also the designation RX on the front of the roll sets. available. Independent testing has shown the Style 77 coupling to be an effective stress relief and vibration attenuation device providing performance superior to braided steel and elastomeric arch-type connectors when used in close proximity to the source of vibration. Refer to publication 26.04 for vibration information. Independent testing has shown that Victaulic Style 77 flexible couplings provide functionality during and after earthquake conditions. Refer to publication 26.12 for further information. • Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date • victaulic.com I Couplings I Standard Flexible I Style 77 I Publication 06.04 06.04 1469 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaul.d victaulic.com I Couplings I Standard Flexible I Style 77 I Publication 06.04 Material Specifications Housing: Botts/Nuts: (specify choice) Ductile iron conforming to ASTM A-536, Grade 65-45- Standard: Heat-treated plated carbon steel, 12. Ductile iron conforming to ASTM A-395, Grade 65- trackhead meeting the physical and chemical 45-15, is available upon special request. requirements of ASTM A-449 and physical requirements of ASTM A-183 Housing Coating: (specify choice) Optional: ASTM F-593, Group 2, Type 316 stainless Standard: Orange enamel. steel oval neck track bolts. Optional: Hot dipped galvanized and others. Optional: ASTM F-594, Group 2, Type 316 stainless steel heavy hex nuts with galling resistant coating. Gasket: (specify choice') NOTE:Additional gasket styles are available.Contact Victaulic for details. Grade"E"EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. Grade"T"Nitrile Nitrile(Orange stripe color code).Temperature range -20°F to+180°F/-29°C to+82°C. May be specified for petroleum products, air with oil vapors,vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+66°C or for hot dry air over+140°F/+60°C. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest'!,tt _r r :, for specific gasket service guidelines and for a listing of services which are not compatible. 06.04 1469 Rev 0 Updated 09/2014 ®2014 Vlctaulic Company.All rights reserved. victaulic.com 2 ✓ctaul,c victaulic.com I Couplings I Standard Flexible I Style 77 I Publication 06.04 Dimensions Style 77 Y 2 < Y [4-2-> Vic. .-.0 3/4-12720-300 mm sizes 14-247350-600 mm sizes Actual Maximum Allow. i Dimensions Approx. Nominal Outside Workingz 2 MaximumPipe End Deflection from Weight Size Diameter Pressure End LoadI Separation 3 Centerline 3 Bolt/Nut" 1 X 1 Y 2 Each Pipe inches inches psi lbs. inches '; Per Cplg. 1 inches/ft. I inches ' inches i inches i lbs. mm mm , kPa N mm Degrees mm/m (No.)size inches ! mm mm mm kg 3/4 1.050 1000 865 0-0.06 2.13 4.00 ! 1.75 1.1 20 26.7 1 6900 ' 3850 0-1.6 3°-24 1 60 2-3/s x 2 54 ! 102 44 0.5 1 1315 ' 1000 1360 0-0.06 0.57 238 4.12 1.75 1.2 2°-43' 2-%x 2 25 33.4 1 6900 6050 0-1.6 48 61 j 105 44 I 0.5 1(4 1.660 1000 2,160 0-0.06 2°-10' 0.45 2-1h x 2 Yz 9610 0 1.6 2.65 5.00 1.88 2.0 32 42 2 6900 _ 38 67 127 48 0.9 1 Yz 1.900 i 1000 2,835 0-0.06 0.40 3.13 1 5.38 1.88 2.1 40 48.3 ! 6900 12615 0-1.6 1°-56' 1 33 2-1/z x 21h ! 79 137 ! 48 1.0 2 2.375 1000 j 4,430 0-0.06 032 3.63 5.88 1.88 2.6 1.-31' 2-1/z x 2'/z 50 60.3 I 6900 19715 0-1.6 26 92 149 ! 48 1.2 257 0 664 i 1000 3955 6900 17592 1_ 0-1.6 - 0 0.06 033 3.43 5.73 I 1.90 3.0 1°-34' I 2 1/z x 2 Yz 87 146 1 48 1.4 57.0 mm � 1 27 21k 2.875 1000 6,490 0-0.06 l°-15, 0.26 2-1/z x 23/4 t 4.25 6.50 i 1.88 3.1 65 73.0 6900 28880 0-1.6 22 108 ! 165 48 1.4 + - - _ 3.000 1000 7,070 0-0.06 0.26 4.38 ! 6.63 1.88 i 3.2 76.1 mm j 76.1 6900 31460 0-1.6 1°-12' L 22 2-1hx2'/a 111 1 168 48 1.5 3 3.500 i 1000 9,620 0-0.06 0.22 5.00 7.13 1.88 3.7 801 1°-2' 2-1/2x x 2 3/a 88 9 6900 46810 0 1.6 18 127 I 181 48 1.7 31/z 4.000 1000 I 12,565 0-0.06 0.19 5.63 8.25 1.88 5.6 0°-54' 2-%x3% 90 101.6 1 6900 55915 0-1.6 16 143 210 ! 48 2.5 4 4.500 1000 15,900 0-0.13 0.34 ! 6.13 8.88 j 2.13 6.7 1°-36' 2-%x 3% p I 100 j 114.3 6900 70755 0-32 28 156 226 54 3.0 108.0 mm 4.250 1000 14,180 j 0-0.13 1°�1 1 0.35 ! 2 16x82.5 6.00 8.63 2.13 11.0 108.0 6900 63100 0-3.2 29 152 219 i 54 5.0 5 5.563 1000 24,300 0-0.130.27 7.75 10.65 2.13 10.6 125 141.3 6900 108135 0-3.2 1 1 8 23 2-/a x 4/a 197 270 54 4.8 o_ 3 1 133.0 mm ; 5.250 1000 21,635 1 0-0.13 0.28 7.63 10.38 2.13 ! 10.0 133.0 6900 96275 0-3.2 10-21' 24 � 2-20 x 108 194 264 54 4.5 5.500 1000 23,745 0-0.13 ! 0.28 8.63 ! 10.65 ' 2.13 10.0 139.7 mm 139.7 1°-18' 2-20 x 108 ' 6900 105665 0-3.2 219 270 54 4.5 24 6 6.625 1000 34,470 0-0.13 0.23 I 8.63 ; 11.88 2.13 12.0 1°-5' . 2-3/ax4Y4 219 302 54 5.4 ' 150 168.3 6900 153390 0-3.2 i 18 ' . 6.250 1000 30,665 0-0.13 0.24 8.63 11.50 2.13 13.2 159.0 mm 159.0 ! 6900 136460 0-3.2 1°-9, 20 2-20 x 108 219 292 ! 54 6.0 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Vlctaullc specifications.Contact Victaullc for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and Installation purposes these figures should be reduced by: 50%for 3/4-31/"/20-90 mm;25%for 4"/100 mm and larger. 4 Number of bolts required equals number of housing segments. 5 Couplings 8,10,127200,250,300 mm sizes available to JIS standards.Refer to I 1. -1 i it.1 i for details. 6 For 14-247350-600 mm Roll Groove systems Victaulic offers the Advanced Groove System(AGS)line of products.Request I in! , -for Information on the Style W77 flexible AGS coupling. 7 CIS size product is designed with two housings and requires two bolts. 06.04 1469 Rev 0 Updated 09/2014 C 2014 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic° victaulic.com I Couplings I Standard Flexible I Style 77 I Publication 06.04 • Y Z e Y • r Z 1 /;° ''i A1irre a"rwl\ 6111 . .... .`1 ,c 3/4-12"/20-300 mm sizes 14-247350-600 mm sizes Actual Maximum Allow. I Dimensions Approx. Nominal Outside Working Maximum Pipe End Deflection from 1Weight Size Diameter Pressure 2 End Load 2 Separation 3 Centerline' Bolt/Nut 4 X V Z Each Pipe inches inches psi • lbs. inches Per Cplg. ' inches/ft. inches inches inches lbs. mm mm kPa • N mm Degrees ; mm/m • (No.)size inches mm mm mm kg 6.500 1000 33,185 0-0.13 0.23 ' 8.88 11.63 2.13 13.2 165.1 mm • 1°-6' 2-3/4x41/4165.1 6900 147660 : 0-3.2 19 226 295 54 6.0 ' 85 j 8.625 800 46,740 i 0-0.13 10°_50' - 0.18 • 2-1/2x5 11.00 i 14.75 2.50 20.8 I 200 219.1 5500 207995 0-3.2 14 279 ; 375 63 9.4 10 5 10.750 800 73,280 ' 0-0.13 0.14 j 13.63 17.13 2.63 31.1 250 273.0 5500 326100 • 0-3.2 00-40' 12 2-1 x 6 346 435 L 67 14.1 125 12.750 800 102,000 ' 0-0.130.12 15.63 19.25 • 2.63 27.8 300 1 323.9 j 5500 453900 . 0-3.2 00-34 9 2-1 x 6 k 397 ! 489 67 • 12.6 146 14.000 I 300 46,180 0-0.13 0.11 . 16.75 I 2025 3.00 39.2 0°-31' 2-1 x 3'h 350 355.6 2065 205500 0-3.2 9 425 514 76 17.8 377.0 ; 14.842 300 1 51,875 0-0.130.11 1739 20.96 2.80 48.8 mm' l 377.0 2065 230,845 i 0-3.2 00-31' i 9 2-1 x 3'/z 442 531 71 22.1 166 16000 300 60320 0 0.13 400 406.4 2065 268425 - 0-3.2 0°-2T 9 I 2-1 x 3'h 476 565 76 20.4 I 0.10 18.75 22.25 3.00 45 426.0 16.772 300 66,245 0-0.130.10 19.69 22.92 . 2.92 56.7 mm' 426.0 2065 294,795 !. 0-3.2 0°-2T 9 2-1 x 3'k 500 F 581 74 ; 25.7 18 6 18.000 300 76,340 i 0-0.13 0.08 21.56 : 25.00 3.13 64.1 0°-24' 2-1'/e x 4 450 48.0 2065 374,265 0 3.2 -- 0.08 22.3 25.86 .04 7 2 i "_ 548 635 80 655 480.0 18898 300 84,105 0-0.1377.2 mm' 00-24' 2-1 /e x 4 20 6 I 20.000 300 94,000 0-0.130o_22' 0.08 r 2-1 Y3 x 4 23.63 ; 27.00 3.13 74.8 500 508.0 2065 418300 0-3.2 7 600 : 686 80 34 22 22.000 • 300 114,000 0-0.13 0°_19, 0.07 j 2-1'h x 4 25.63 29.13 3.13 82.6 550 559.0 2065 507300 0-3.2 6 651 ' 740 80 37.5 530.0 ' 20.866 300 102,535 0-0.13 0.08 ! ( 24.29 27.80 3.07 91.7 mmr 0°-22' 2-1'/ex4 j i mm 580.0 2065 455 530.0 ! 2065 /591 0 3.2 0.07 2-1'/s x 4 26.76 30 01 3 12 ( 41.6 58 92.8 0.0 22 835 300 102,380 0-0.13 x_19 6 ; 680 762 79 42.2 24 4 24.000 250 113,000 0-0.130°-16, 0.07 2-1 1/2 x 4 27.75 31.00 3.19 89.6 600 609.6 : 1725 502850 , 0-3.2 6 705 787 81 40.7 630.0 ' 24.803 250 104790 0-0.13 0.07 ' 28.42 32.16 3.12 ' 96.8 • I mm' 630.0 1725 457,416 0-3.2 0°-18' 6 2-1'/e x 4 722 817 79 44 AGS See Style W77,Publication 20.03 1 14-24 350-600 ! AGS* . . 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaullc for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and Installation purposes these figures should be reduced by: 50%for 3/4-3 1"/20-90 mm;25%for 4"/100 mm and larger. 4 Number of bolts required equals number of housing segments. 5 Couplings 8, 10,12"/200,250,300 mm sizes available to JIS standards.Refer to. i I. i . ! victaulic.com I Couplings I Standard Flexible I Style 77 I Publication 06.04 • • Installation Note Reference should always be made to the I-1,0, -. .d-F r Ir I II r.r F i,-.l for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are Included with each shipment of Victaullc to be installed in accordance with current Victaulic installation/assembly Instructions. products for complete installation and assembly data,and are available In PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic,com. equipment without notk e and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaullc'Is a registered trademark of Victaulic Company, 06.04 1469 Rev 0 Updated 09/2014 ®2014 Vlctaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic Victaulic® Grooved End Fittings jctaulad 07.01 " 0 . Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a fr galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or • No.20 Tee No. 10 Elbow with shoulders conforming to standard steel pipe outside Certifications/Listings diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 °®• i LPCB Vic-Flange°adapters, check disc clearance dimensions with I.D.dimension of fitting. When supplied as"hot dip galvanized"the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold+86°F/+30°C potable water service and ANSI/NSF 372:No.10 90°Elbow,No.11 45°Elbow,No.12 22 1/2° Elbow,No.13 11 1/4°Elbow,No.100 90°Long Radius Elbow,No.110 45°Long Radius Elbow,No.20 Tee,No.25 Tee with Grooved Branch,No.30 45°Lateral, No.60 Cap,No.50 Concentric Reducers,No.51 Eccentric Reducers. Note:The following Victaulic fittings are VdS approved:No.10 90°Elbow,No.11 45°Elbow,No.20 Tee and No.60 Cap. Note:The following Victaulic fittings are LPCB approved:No.10 90°Elbow, No.11 45°Elbow,No.12 22 1/2°Elbow,No.13 11 1/4°Elbow,No.30 45°Lateral, No.30-R Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Product Description Victaulic offers a broad line of fittings in sizes through 60"/1500 mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances.Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to publication 14.04_ for fittings available for plain end applications). Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.corn I Fittings I Grooved End I Publication 07.01 07.01 1449 Rev X Updated 10/2014 ®2014 Victaulic Company.All rights reserved. 1 ✓ctaukc victaulic.com I Fittings I Grooved End I Publication 07.01 • Flow Data (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/2°elbow is approximately one-half the resistance of a 45°elbow. Values of mid-sizes can be interpolated. Size Dimensions 90°Elbows 45°Elbows Tees ' No.100 No.110 Actual Outside • No.10 1 1/2 D Long No.11 1 2 D Long Nominal Size Diameter Std.Radius Radius Std.Radius Radius Branch Run inches inches feet feet feet feet feet feet mm mm r meters meters meters meters meters ! meters 1 1.315 1.7 0.8 _ 4.2 1.7 25 33.7 0.5 - 0.2 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 50 60.3 1.1 0.8 0.5 0.3 2.6 1.1 76.1 mm 3.000 4.3 2.1 10.8 4.3 76.1 1.3 0.7 , - 3.3 1.3 3 � 3.500 5.0 3.8 2.6 1.6 13.0 5.0 80 889 1.5 1.2 i 0.8 0.5 4.0 j 1.5 4.250 6.4 _ 3.2 - 153 6.4 108.0 mm • 108.0 2.0 0.9 4.7 2.0 4 4 4.500 6.8 5.0 ' 3.4 2.1 16.0 6.8 100 114.3 2.1 1.5 1.0 , 0.6 4.9 2.1 133.0 mm 5.250 8.1 _ 4.1 - 20.0 8.1 133.0 2.5 1.2 6.2 2.5 5.500 8.5 - 4.2 21.0 8.5 139.5 mm -, J - - 139.7 2.6 1.3 6.4 2.6 5563 8.5 _ 4.2 _ 21.0 85 125 141.3 2.6 1.3 6.4 2.6 159.0 mm 6.250 9.4 - 4.9 - 25.0 9.6 159.0 2.9 1 5 7.6 2.9 6.500 9.6 5.0 i 25.0 ! 10.0 165.1 mm _; - 165.1 i 2.9 15 7.6 3.0 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 150 168.3 3.0 I 2.3 15 0.9 7.6 3.0 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 250 273.0 5.2 I 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 145 10.0 6.0 50.0 20.0 , 300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 fi I � I 14 14200 24.51 ! 15.8 18.5' 11.0 70.0 23.0 350 355.6 7.5 4.8 5.6 I 3.4 21.3 7.0 16 16.000 28.0' 18.0 21.0' 13.0 80.0 27.0 400 406.4 8.5 5.5 6.4 4.0 24.4 8.2 18 18.000 31.0' , 20.0 235' 14.0 90.0 30.0 450 457.0 1 9.5 6.1 7.2 4.3 27.4 ; 9.1 ' 20 20.000 34.0' � 22.5 25.5' 16.0 100.0 33.0 800 508.0 I 10.4 6.9 7.8 4.9 305 r 10.1 24 24.000 42.0' 27.0 , 29.5' 19.0 120.0 j 40.0 600 610.0 12.8 8.2 9.0 5.8 36.6 12.2 AGS fittings available up to 60"11500 mm.Contact Victaulic for details. AGS- - 1 Fitting flow data for 14-24"/350-600 mm size No.10 and No.11 Elbows Is based on fittings for Style 07 and 77 couplings.For flow data on AGS fittings(No.W10 and No.W11 Elbows),refer to .l I, r.r1:-?0'. 07.01 1449 Rev X Updated 10/2014 ®2014 Vlctaullc Company.All rights reserved. victaulic.com 4 ✓CtauliC victaulic.com I Fittings I Grooved End I Publication 07.01 Dimensions Elbows No. 10 90° Elbow No. 11 45° Elbow No. 12 22 1/2° Elbow No. 13 11 1/4° Elbow No. 100 90° Long Radius Elbow No. 110 45° Long Radius Elbow ti-T i C to E i• CtoE1 1 40.,,, w\ �� Ct^E I I= C to E� '' .� - CtoE` Ct E to 1. alill 7- • No. 10 No.11 No.12 No. 13 No.100 No. 110 Standard and GSNK No.100 No.110 No.10 No.11 No.12 No.13 90°Long Radius ' 45°Long Radius Size 90°Elbow 45°Elbow 22W Elbow 11W Elbow Elbow Elbow i Actual 1 Approx. Approx. Approx. Approx 1 Approx. Approx. 1 Outside , Wgt. Wgt. Wgt. i Wgt. I Wgt. Wgt. Nominal Size. Diameter ' C to E Each C to E Each C to E Each C to E I Each C to E ! Each ! C to E i Each inches j inches inches 1 lbs. 1 inches lbs. inches lbs. inches I lbs. inches I lbs. inches 1 lbs. mm mm mm kg mm k9 mm kg mm ; kg ; mm I kg mm 1 kg '/a 1.050 2.25 0.5 1.50 0.5 :1.63(sw)1 1.38(sw)i t 2.50(sw)' 0.4 1.88(sw)1 0.3 20 1 26.9 57 l 0.2 38 1 0.2 41 35 j 64 I 0.2 ; 48 I 0.1 1 1.315 2.25 0.6 1.75 0.6 3.25 2 0.6 i 1.38(sw) 0.3 2.88(sw)I 0.6 2.25(sw)11 0.5 1 /a 1.660 2.75 1.0 1.75 1 0.9 1.75 0.8 0.3 35 l 0.1 73 0.3 57 . 0.2 32 1 42.4 70 1 0.5 I 44 OA ! 44 0.4 1.38 5sw)I 0.503.25 35w) 1.102.38 0sw)' 0.7 1 th 1.900 2.75 ! 1.2 I �. - 0.3 1.75 ( 0.9 1.75 0.8 1.38(sw) 0.5 3.63(sw)l 2.2 2.50(sw)', 1.3 40 48.3 70 , 0.5 44 0.4 44 0.4 35 0.2 1 92 1 1.0_ 64 I- 0.6 2 2.375 3.25 ! 1.8 2.00 1.3 1 1.88 1 1.2 1.38 1.0 438 t 2.5 i 2.75 1.8 50 t 95 1.5 57 1 j z I - -_ .0 2.8 0.8 65 60.3 83 0 8 51 I 0.6 48 0.5 35 0.5 111 I 1 1 73.0 8 - 13- 7 -_ 376 1.3 2/z 2.875 3.75 3.2 215 2.2 4.00 2.3 1.50 1 1.1 5.13 3.4 • 76.1 mm 3.42.25 I__- ' 138 130 1.5 76 1.3 .0 102 3.000 395 1. I 257 1.5 t - - ! 95 1,7 I 57 i 1.5 57 0 38 0.5 � 3 3500 4.25 I 45 250 3.1 4.50 3.1 150 2.1 5.88 6.0 338 4.9 • 80 1 88.9 108 I 2.0 64 14 114 1.4 38 10 149 � 2.7 86 2.2 3 th 4.000 4.50 5.6 2.75 4.3 2.50(sw) 4.0 1.75(sw), 2.7 90 101.6 114 1 2.5 70 2_0 I 64 1.8 ' 44 1 1.2 - - - 4 4.500 w 5.00 - 7.1 1 3.00 5.6 1 2.88 5.6 1.75 3.6 7.50 1 12.3 4.00 1 7.3 100 114.3 127 32 76 2.5 73 2.5 44 1.6 191 ! 5.6 1 102 1 33 108.0 mm j 4.250 5.00 11.0 3.00 I 5.6 - _ 108.0 127 5.0 76 2.5 1 - - - - 4 th ! 5.000 5.25(sw); 10.0 3.13(sw) 6.0 -3.50(sw) 6.6 ,1.88(sw); 4.2 ; - ; 2.7 89 3.0 1 48 I 1.9 - - 120 127.0 133 4.5 791 5 5563 550 11.7 325 8.3 2.88(sw) 7.8 2.00(sw) 5.0 9.25(sw)! 18.0 4.88(sw)1 14.8 125 1413 140 ; 53 83 3.8 73 3.5 51 2.2 235 I 8.2 1 124 6.7 133.0 mm 5250 550 ' 11.7 325 ' 8.3 1330. 140 5.3 1 83 3.8 - - - j - - - - - 139.7 mm 5500 550 11.7 325 8.3 2.88 - _2.00 139.7 140 I 53 83 3.8 73 51 I i i - - - 6 6.625 6.50 172 3.50 10.8 6.25 z 122 2.00 7.0 10.75 1 304 550 17.4 150 168.3 165 7.8 89 4.9 ' 159 5.5 51 i 3.2 1273 13.8 1 140 . 7.9 2 Gooseneck design,end-to-end dimension fittings in this size,contact your nearest Victaulic sales representative. 3 For 14"/350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings In this size, contact your nearest Vlctaullc sales representative. 4 Chinese standard sizes 07.01 1449 Rev X Updated 10/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic victaulic.com I Fittings I Grooved End I Publication 07.01 Tees,Crosses and True Wyes No. 20 Tee No. 35 Cross No. 33 True Wye No. 29M Tee with Threaded Branch -CtoE y �CtoE� mumI CCtoLE Cto 't;# I CEmmmEmm =EN= 1 11 CE CtoTE I No.20 No.35 No.33 No.29M No.20 No.35 No.33 No.29M Size Tee Cross(sw) True Wye(sw) Tee with Threaded Branch Approx. Approx, Approx. Approx. Actual Outside Weight ' ' Weight i Weight Weight Nominal Size Diameter C to E Each C to E Each C to LE I C to SE Each C to GE C to TE ! Each inches inches inches lbs. inches lbs. inches inches lbs. inches inches lbs. mm mm mm kg ! mm kg I mm mm kg mm , mm kgI V. I 1.050 225 0.6 225 I 0.9 2.25 2.00 0.7 225 2.25(sw) 0.6 I 20 I 26.9 57 0.3 57 0.4 57 51 0.3 57 57 0.3 1 1.315 2.25 1.0 2.25 1.3 2.25 2.25 1.1 2.25 2.25 1.0 25 33.7 57 0.5 i 57 0.6 57 57 0.5 57 57 0.5 1Y. 1 1.660 2.75 1.5 2.75 2.1 2.75 2.50 13 2.75 2.75 1.5 32 I 42.4 70 0.7 70 1.0 70 I 64 0.7 70 70 0.7 � 11/2 I 1.900 2.75 2.0 2.75 2.5 2.75 I 2.75 1.8 2.75 2.75 2.0 40 48.3 70 1 0.9 I 70 1.1 70 70 0.8 70 70 0.9 2.3 3 - -- - 4.25 2 2.375 3.25 3 0 3.25 3.8 3.25 2.753.25 4.25 3.0 50 60.3 ! 83 14 83 1.7 83 70 1.1 83 108 1.4 2.5 I 21 2.875 3.75 I 4.3 3.75 6.1 3.75 3.00 4.3 3.75 3.75 43 65 ! 73.0 95 - 2.0 95 2.8 ! 95 76 2.0 , 95 95 -j 2.0 76.1mm 3.000 395 5 2 - - _ - 3.75 3.75(sw) 5.2 33.500 415 2.4 95 95 2.4 6.8 4.25 103 I 4.25 3.25 6.14.25 I 4.25 � 6.00 6.8 4 80 88.9 1 108 3.0 - 108 4.8 108 f 83 - 2.8 108 152 3.1 31 i 4.000 4.50(sw) 7.9 4.50 11.5 4.50 3.50 i 9.6 1 4.50 4.50(sw) 7.9 90 101.6 114 3.6 114 i 52 I 114 89 4.4 114 114 3.6 108.0 mm 4.250 5.00 15.5 _ - _ _ - 5.00 5.00(sw) 153 108.0 127 7.0 ! 127 127 7.0 4 4.500 5.00 11.9 5.00 15.8 ! 5.00 3.75 9.8 5.00 7.25 11.9 100 1 114.3 , 127 5.4 127 7.2 j 127 95 44 127 I 184 5.4 41/2 5.000 5.25(sw) I 15.0 5.25 18.5 5.25 5.25(sw) ! 15.0 120 127.0 133 6.8 i 13.3 8.4 133 133 6.8 5.50 5.50(sw) 133.0 mm 5250 5.50 ! 17.8 _ _ _ _ 178 133.0 140 8.1 - 140 140 8.1 139.7 mm .5 .50(5 - _ - - _ 5.50 5.50(sw) 17.8 5 5.563 5 50 17.8 140 140 8.1 5 500 5 50 � 17.8 139.7 140 ' 8.1 ' 5.50 i 20.0 5.50 ' 4.00 I 15.0 5.50 5.50(sw) 178 125 141.3 I 140 8.1 140 j 9.1 j 140 102 6.8 140 140 8.1 6.25159.0 165 123 j _ 6.50 6.50(sw) 27.1 159.0 mm 1590 6.50 165 165 123 • 1651 mm 6.500 6.50 22.0 6.50 28.0 I _ ' 6.50 6.50(sw) 22.0 . - i 165.1 165 10.0 165 12.7 165 165 10.0 6 For 147350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings In this size, contact your nearest Victaulic sales representative. 7 Chinese standard sizes 07.01 1449 Rev X Updated 10/2014 ®2014 Victaullc Company.All rights reserved. victaulic.com 8 ✓ctaulic II victaulic.com I Fittings I Grooved End I Publication 07.01 Reducing Tee No. 25 Grooved Branch •rctoEi -ctoEi No. 29T Threaded Branch 111111111 _{ cc? o �CtcE1 j CtoEi tE to E II,hi C II,I:. No.25 No.29Tto tc E No.29T MIS_I No.25 ' w/Thd. No.25 No.29T Size Std. Branch Approx. Weight • No.29T I Nominal Size C to E C to E Each No.25 : w/Thd. inches inches inches lbs. Size Std. Branch Approx° mm mm mm kg ; Weight 44 3/+ 5.00(sw) 5.00(sw) 8.0 . Nominal Size C to E C to E ' Each x x 100 100 20 ' 127 127 3.6 ' inches inches j inches lbs. 1 5.00 5.00 7.8 mm mm mm kg 25 127 127 3.5 x x 1 1 3/+ 2.25(sw) 2.25(sw) 1.0 1 1/+ , 5.00(sw) 5.00(sw) 9.6 25 25 20 57 57 , 0.5 , 32 127 127 4.4 1 1/+ 1 1/+ 1 2.75(sw) j 2.75(sw) 13 1 Y ' 5.00 ! 5.00 10.2 32 x 32 x 25 70 70 0.6 40 , 127 127_ 4.6 1% 1 1/2 44 2.75(sw) 12.75(sw) ; 1.52 5.00 5.00 11.2 40 x 40 x 20 70 70 i 0.7 50 127 127 5.1 1 2.75(sw) 2.75(sw) 1.5 2% 5.00 : 5.00 11.4 25 70 70 0.7 65 127 127 5.2 1 1/+ 2.75(sw) 2.75(sw) 17 j 3 5.00 5.00 11.6 i 32 70 70 0.8 80 127 127 5.3 2 2 ;/+ 3.25 3.25 25 5.50 w) 5.50(sw) 14.0 50 x 50 x x 20 i 83 83 125 125 1.1 x 25 140 6.4 r1 • 325 3.25 1 52 5.5 11 40 2.7 (0w) j 5.50(sw) 14.3 25 83 83 I 12 40 140 140 6.5 1 1/+ 3.25(sw) j 3.25(sw) - 1.8 2 5.50(sw) ! 5.50(sw) 14.5 32 83 83 0.8 50 140 140 6.6 1 1 • 3.25 3.25(sw) 3.0 2 h 5.50 5.50(sw) 15.2 - - 40 1 83 83 1.4 65 140 140 6.9 j 211 21/2 1/4 13.75(sw) 13.75(sw) 3.9 3 5.50 5.50(sw) 16.6 I x x _ 140 7.5 65 65 20 95 95 1.8 80 140 1 3.75 i 3.75(sw) 3.8 4 5.50 5.50(sw) 16.7 1 25 ! 95 95 1.7 100 140 140 I 7.6 1 1/+ 375 375 42 6 6 1 6.50(sw) 6.50(sw) 23.0 • 32 95 95 1.7 150 x 150 x 25 165 165 10.4 1 1/2 ! 3.75 3.75 3.9_ 11/2 6.50(sw) 6.50(sw) 24.0 40 it 95 95 1.840 165 165 10.9 2 3.75 3.75(sw) 4.5 _ { 2 6.50 6.50 21.6 50 95 95 2.0 ' 50 165 165 9.8 3 3 3/+ 425(sw) 4.25(sw) 57 21/2 6.50 6.50 21.4 80 x 80 x 20 108 108 ! 2.665 165 165 11.7 1 4.25 4.25 6.1 3 6.50 6.50 26.5 i25 108 108 I 2.8 80 165 165 12.0 • 11/+ 425 425 8.0 4 6.50 6.50 25.0 32 108 108 3.6 100 ' 165 165 11.3 1 k I 4,25 4,25(sw) I 6.5 5 6.50 6.50 1 232 I 40 108 108 ' 2.9 ! 125 165 ' 165 10.5 ° 2 4.25 4.25(sw) 6.2 6 k 61/2 3 6.50 6.50(sw) 24.0 � 50 ' 108 108 2.8 ! 165.1 x 165.1 x 80165 165 10.9 2/2 4.25 1 4.25(sw) 6.4 4 6.50 6.50(sw) 25.0 65 108 108 2.9 100 165 165 11.3 8 For 14"/350 mm and larger roll grooved systems,Victaulic offers the 8 For 14"/350 mm and larger roll grooved systems,Victaullc offers the Advanced Groove System(AGS).For pricing and availability of cut groove Advanced Groove System(AGS).For pricing and availability of cut groove fittings In this size,contact your nearest Victaulic sales representative, fittings In this size,contact your nearest Victaulic sales representative. 9 Cast fitting available.Contact Victaulic for details. 9 Cast fitting available.Contact Victaulic for details. • 07.01 1449 Rev X Updated 10/2014 0 2014 Victaullc Company.All rights reserved. victaulic.com 10 ✓ctaul.c° CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Reducing Coupling a mus FM vdS I PCBI 104-1.3/05 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 750 The Style 750 Reducing Coupling permits direct reduction on the piping run.Designed to replace two couplings and a reducing fitting,the Style 750 features a special reducing gasket for pressure responsive sealing.A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. 11.4 1111 u 11 MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Housing Coating:Orange enamel • Optional: Hot dipped galvanized and others Gasket:(Specify choice): • Grade"E"EPDM(All other sizes) EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110`C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180'F/+82°C potable water service.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range.Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140`F/+60°C. * Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional:Assembly Washer:Galvanized,carbon steel Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Pam Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.O 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtaLIiC` REV J i;N.:>3 1 =i irrPIPE 1R ,i . !�:� ilit.� 06. 8 p _ € _it g Co tt..,, , g STYLE 750 DIMENSIONS Max.Work Allow.Pipe bolt/Nutt Approx. Size Pressure' Max.Erd Load' Eir Sep.; Deflect.Fr.Cc Nd-Size Dimension:-Inches/rim W t Each i mad Per Pipe tncIros/mm kPa Lbs.e psi bicbes/mm � .z laclres X Y 2 .- ,_ill... 2 1 350 500 0-0.07 0.20 338 5.28 1.88 2.7 50 x 25 2410 2225 0-1.8 C•`-5T 17 2-3/8x2 85 134 48 1.2 1'h 350 1000 0-0.07 0.20 338 5.28 1.88 2.0 ii. 40 2410 4450 0-1.8 Cr-57' 17 2-3/8 x 2 85 134 48 1.0 21/2 x . 2 500 2215 0-0.07 0.16 4.00 593 1.88 3.1 65 50 3450 9850 0-1.8 C -47 14 2-3/8 x 2 102 151 48 1.4 76.1 mm x 2 350 1550 0-0.070.16 4.38 6.53 1.88 4.6 50 2410 6900 0-1,8 0°-4T 14 2- x23/, 111 158 48 2.1 3x , 350 1550 0-0.07 G.-39' 0.13 2-1/2x 2 3/0 4.75 7.13 1.88 4.9 80 co 2410 6900 C•-1.8 11 121 181 48 2.2 . 2'h 500 3250 0-0.07 0°-39' 0.13 2-1/2x21/4 4.75 7.13 1.88 4.3 65 3450 14460 0-1.8 11 121 181 48 2.0 88.9 mm x 76.1 mm 350 2475 0-0.07 C°-39' 0.13 2-'/2x23/. 4.75 7.13 1.88 4.2 2410 11010 0-1.8 11 121 181 48 1.9 4 2 350 1550 0-0.13 0.28 6.25 8.90 225 8.1 100 x 50 2410 6900 0-3.2 1'-19' 25 2-5/8 x 31/4 159 226 57 3.7 21/2 350 2275 0-0.131°-19' 028 2-5/8 x 3'/a 6.25 8.90 2.25 8.6 65 2410 10125 0-3.2 25 159 226 57 3.9 3 500 4810 0-0.13 1°-19' 0.28 2-5/8x3% 6.00 8.90 225 6.7 80 3450 21400 0-3.2 25 152 226 57 3.0 350 2475 0-0.13 0.28 6.25 890 225 6.9 114.3mm x 76.1mm 2410 11014 0-3.2 1°-19' 25 2-5/8x3'/. 159 226 57 3.1 5 4 350 5565 0-0.131 0.22 7.18 10.70 2.13 11.2 125 x 100 2410 24765 0-3.2 -3 19 2- x a'/. 182 272 54 5.1 6 4 35C 5565 0-0.13 0.18 8.63 11.90 225 16.7 150 x 100 2410 24765 0-3.2 0°-52' 15 2-3k x 4'/a 181 302 57 7.6 5 350 8500 0-0.130.18 8.31 11.90 225 12.9 125 2410 37825 0-3.2 0°-52' t5 2-1/4x4'/< 211 302 57 5.9 165.1 mm x 4 350 5565 0-0.130.19 8.63 11.90 225 15.2 100 2410 24765 0-3.2 0°-55• 16 2-3kx4% 219 302 57 6.9 8 6 350 12060 0-0.13 0.13 10.81 14.88 2.50 22.4 200 x 150 2410 53645 0-3.2 G -38 11 2-7/8 x 5 275 378 64 10.2 350 11610 0-0.13 013 10.75 14.88 2.50 23.2 219.1 mm x 155.1 mm 2410 51645 0-3.2 0 -38 11 2-7/8 x 5 273 378 64 10.5 10 8 350 20450 0-0.13 0.9 13.12 17.26 2.62 31.4 273 x 219.1 2410 90970 0-3.2 0`-25' 8 2-1 x 5%z 333 438 67 14.2 Style 750 Reducing couplings should not be used with end caps(4501 in systems where a vacuum may be developed.Contact Victaulic for details. Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based cn smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/4-31/2720-90 mm;25%for 4/100 mm and larger. @ Number of bolts required equals number cf housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Vi::taulic piping products. a Y 4Z1 Z addiellit\ 11011 As, lei Os O - ...v......;000..."0,`, , ,r '=' X _ Ma lu v� Il it www.victaulic.com eCtaUl1C VICTAULIC IS A REGISTERED TRADEMARF.OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY,ALL RIGHTS RESERVED. ._... ---.__ 1:0(6 2 RFv I ,_ Chhtu'( ', i ` TEEJ- r-iCA[u Cii;x Li a�= 06.08 Dr-; a f fil f: $3,-O, c, STYLE 750 r. FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short bodyreducingpipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data Is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING Equiv.Pipe Equiv.Pipe Size Length Size Length Nominal Nominal _ Size - Sm.Dia. Size Sm.ilia. . 1nEheo nm m Tithe trams 1i:elfic ,.... 2 1 5.9 1 2 2.7 50 x 25 1.8 25 x 50 0.8 11/2 2.0 11/2 2 1.9 40 0.6 40 x 50 0.6 21 2 1.9 2 21 1.0 65 x 50 0.6 50 x 65 0.3 76.1 mm x 2 1.9 1.0 50 0.6 76.1 mm 03 3 2 5.5 3 3.5 80 x 50 1.7 80 1.1 21/2 3.8 4 3.0 65 1.2 100 0.9 88.9 mm x 76.1 mm 3.8 2'/z 2.5 12 65 x 80 0.8 4 2 6.0 4 3.0 100 x 50 1.8 100 0.9 21/2 6.0 76.1 mm x 88.9mm 2.5 65 1.8 0.8 3 6.0 114.3mm 3.0 80 1.8 0.9 114.3 ram x 76.1 mm 6.0 3 4 2.5 1.8 80 x 100 0.8 5 4 3.0 4 5 33 125 x 100 0.9 100 x 125 1.0 6 4 6.0 6 4.6 150 x 100 1.8 150 1.4 5 4.5 165.1mm 4.6 125 1.4 1.4 165.1mm x 4 6.0 5 6 2.3 100 1.8 125 x 150 0.7 8 6 7.3 6 8 6.0 200 x 150 22 150 x 200 1.8 219.1 mm x 165.1 mm 7'3 165.1 mm x 219.1 mm 5.4 2.23 1.65 10 8 8.7 8 10 6.3 273 x 219.1 2.65 219.1 x 273 19.2 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaUhe-_,... RE 1 0l7'.`'i< 3 .CARBON STEEL PIPE—GROOVED COUPLINGS ..._ 06+08 Reducing ou c STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV J UPDATED 08/2012 jct8UI1�.' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ,._,___.:.._ ,. Dyna-Thread® - M-COAT® Submittal Data Sheet ® Full Line Sch-40 Replacement Dyna-Thread— M-COAT Specifications Dyne-Thread'—M-Coat' sprinkler pipe represents an engineering NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprk ler pipe industry.It combines the safetyIn;mm In;mm Lbs/F•kg/m Lbs/Ft;kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior • 1" 1.080 1.330 1.75 11.39 1.00 • hydraulic advantages. 25 27.4 2.0 2.60 f 114" 1.408 1.870 2.54 9.50 1.00 • ® Comparison to Schedule 40 32 35.8 2.8 3.78 — — 0 11/2" 1.639 2.290 3.22 9.14 1.00 Dyna-Threa&—M-Coat" inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — — giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall ® c® 111> thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— ...ROVED M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for O American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA, Canada, Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed ®Specifications & Approvals thread, assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with f1FFA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems. Dyna Thread—M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.D.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as di ops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. • Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: allied Customer Service: (800)882-5543 Fax: (800)659-7730 www.alliedtube-sprinkler.com - • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUITHarvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 .PART OFAkatOr@ ©2013 Atkore International, Inc.All Rights Reserved.STP-S3-4M-1301 Ductile Iron Threaded Fittings ..,, .,... _. . _.._, ._.. _........„._ ,.., .... .„.„, ...... ,,,,,„ .,. .,.; .„..., •._ „.„ _..... . .•„,..„, .,' ,:-• '.5 - .• .-...,..:-- -.....-.. ,,. , ,-' ----__ .,.,•-..-61F.....1.; - ,A 4 , . , - • . . . • . ,. . v , .,.- .,, ,i .• 41)1 . , , .,,•• i . . ,.. . 1 0 . „ .. , . •. • ., - . , . . ( ..4 . I - 1 . . 1 . - . .. , ,„, ..-.: • „. i ',. , . ..,... ....., . . ....- . -•--,. ,,„. .,:,,,,- x :11-7-7,1t-i4.(,. ( §( I I I A 3 y7„,.; . Ductile Iron Threaded Fittings Specifications • © branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP c UL us • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 ,.,...lwar Ductile Iron Fittings - Class 300 UL/FM c ® us APPROVED Fig. 35E 3-90° Elbow LISTED A Size A Packing Weight in Part Number in Inner Master lb --1\11 +\ 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 �_�n 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow � ) Size Part Number A B Packing Weight • `..,� in in in Inner Master lb la V \ • 3/4 x 1.22 80 160 0.3 • 1 x 1/21/2 35RE301000435RE3006004 1.21.206 1.36 70 140 0.4 11P11)onA 1 x 3/4 35RE3010006 1.38 1.45 35 50 10070 0.4 V •1-1/4 x 1/2 35RE3012004 1.34 1.53 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 • 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 3511E3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 351;1E3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 V...' 2 x 1-1/4 35RE3020012 1.90 2:10 12 24 1.3 11 i 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 - T 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 flt 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size Part Number A Packing Weight A in in Inner Master lb `' 7.- 1/2 35F 3004 0.88 150 300 0.2 4 3/4 35F 3006 0.98 80 160 0.3 k 1 35F 3010 1.13 40 80 0.5 _ 1-1/4 35F 3012 1.29 25 50. 0.7 1-1/2 35F 3014 1.44 20 40 1.0 t�i �A 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight allin in Inner Master lb u� 1/2 35T 3004 1.13 80 160 0.3 � �A 3/4 35T 3006 1.31 30 60 0.5 I 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com rif d Ductile Iron Fittings - Class 300 UL/FM c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Packing Weight jD - in in in in Inner Master lb SII C 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 -Y 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 a - 4.` 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1:75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 • 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 • 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 ' 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 ' 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65. 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1:75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 • 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 rril 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1:4 19 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 .. 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 { ' 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 IP • 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82. 1.75 1.88 14 28 1.3 • 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 ' 2 x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 _, 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 ;A 2 x i 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 _ 0 • 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 358T3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size A B C Packing Weight Part Number J%EnP Ic in in in in Inner Master Ib 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 IMO: 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 ..' 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A B 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 3513T3012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 358T3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wvv .smithcooper.com 112 1 4 . Ductile Iron Fittings- Class 300 UL/FM F:,;itt? 71 C13US APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED 1111 ' Size Part Number A Packing Weight inin Inner Master lb 1/2 35C P3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 "� 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 • Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight 'B in in Inner Master lb ® A • 1 x 1/2 35RC3010004 1.69 80 160 0.3 If ' _ 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing 1 Size A PackingWeight Part Number g B ) in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 7 i ciA 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 i 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 ' 2 x 1 35HB3020010 1.38 40 80 0.6 iii I 2x 1-1/4 35HB3020012 1.38 40 80 0.6 rti+ 2 x 1-1/2 35HB3020014 1.38. 40 80 0.6 71 Fig. 35SP3 -Square Head Plug Size A Packing Weight Part Number ,a. in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 10711 � IA 1 35SP3010 1.25 200 400 0.1 1111 1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight Part Number P in in Inner Master lb 1 35U 3010 2.19 20 40 1.0 1111 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 ""�r`.�� 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323)890-4456 • www.srninccooper.com FireLock® Buterfly Valve ✓ctaul.cf Style 705 with Weatherproof Actuator 10.81 Material Specifications: E Body: Ductile iron conformingto ASTM A-536, grade "���i� 4 65-45-12 End Face, 2 —6"/50— 150 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer, 8— 127200—300 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 • Approvals/Listings: Coating: Black alkyd enamel cons FM vds LPCB Disc: Ductile iron conforming to ASTM A-536, grade • iu,Euoal000l 104;/04 65-45-12, with electroless nickel coating conforming to v Fuld_ lu.0 to! II jr,LOA,. ASTM B-733 Seat: Product Description: Grade "E" EPDM The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a Stems:416 stainless steel conforming to ASTM A-582 ductile iron body and disc with EPDM seats. Designed for fire protection services only.Victaulic FireLock Stem Seal Cartridge: C36000 brass Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Bearings: Stainless Steel with TFE lining Contact Victaulic for details of agency approvals. Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 2—8750—200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing 10—12"/250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved ' Submitted By Date Date victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 10.81 5662 Rev F Updated 11/2014 C 2014 Victaullc Company.All rights reserved. 1 ✓ctau6c victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Approvals and Listings: ApprovaVListing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2"/50mm up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 2/,"/65 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3"/80 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4"/100 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5"/125 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa • 6"/150 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psl/2068kPa ! n/a up to 300psi/2068kPa 8"/200 mm up to 300psi/2068kPa up to 300ps1/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12"/300 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 10.81 5662 Rev F Updated 11/2014 ®2014 Vlctaulic Company.All rights reserved. victaulic.com 2 •ctaul.c victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Dimensions: Allib. I mot-0 .: 0H _ x- . '%1 vilkit'Th\• ( 1 Nt MO -; - G E-. A--wD - NOTE:OPTIONAL W/15MM TAP AVAILABLE. CONTACT VICTAULIC FOR DETAILS. Dimensions Actual Nominal Outside : E to E Size Diameter A BC D E F G DIA H J inches inches inches inches inches inches inches inches inches inches inches mm i mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 _ _ 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 j 101.6 107.2 114.3 53.8 h 2.875 73 73.0 3.77 2.28 7.54 - _ 4.00 4.22 4.50 1.77 4-- 95.8 57.9 I 191.5 � 101.6 107.2 114.3 45.0 3.000 _ . - - . 76.1 mm 3.77 2.28 7.54 - i - 4.00 4.22 4.50 1.77 j 76.1 95.8 57.9 1913 101.6 107.2 114.3 45.0 3 3500 3.77 i 2.53 7.79 _ I _ 4.50 4.22 4.50 1.77 ~ 88.9 • 88.9 j 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 5.50 4.22 4.50 2.20 108.0 117.6732 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 1 2.88 8.815.50 4.22 ; 4.50 2.20 I - 114.3 114.3 117.6 73.2 223.8 - 139.7 107.2 114.3 55.9 133mm 5.250 5.88 3.35 10.88 - _ 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276,4 166.6 ' 157.2 160.0 65.5 139.7 mm 5.500 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 139.7 149.4 85.1 ; 276.4 ; 166.6 157.2 160.0 65.6 19 630 2.58 5 5.563 5.88 3.35 10.88 _ _ 6.56 6 141.3 141.3 ; 149.4 85.1 276.4 i 166.6 157.2 160.0 65.5 159mm 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1 mm 6.500 5.88 3.84 1138 _ 0.41 7.52 6.19 6.30 2.58 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 I 6 6.625 5.88 3.84 11.38 _ 0.41 7.52 6.19 ! 6.30 1.90 168.3 168.3 149.4 97.5 1 289.1 10.4 191.0 1 157.2 I 160.0 48.3 8 8.625 1 5.33 5.07 13.53 0.80 1.47 10.00 1 6.19 8.10 2.33 - 219.1 1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 - i - - -- 6.40 ...6.37 .10 10.750 ' 15.64 1.41 1.81 12/5 8.10 9.00 - 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 _ 323.9 323.9 165.1 186.9 422.7 - 58.4 71.1 362.0 205.7 228.6 c 10.81 5662 Rev F Updated 11/2014 ©2014 Vlctaullc Company.All rights received. victaulic.com 3 ✓Ctau6C victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/m inches inches of pipe 2 2.375 6 50 60.3 1.8 2'/ 2.875 6 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 • 100 114.3 2.4 108 mm 108mm 8 ' 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 • 139.7 mm 5.500 12 139.7 3.7 I 6 6.625 14 150 168.3 42 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 165.1 4.2 8 8.625 j 16 I 200 219.1 4.9 10 10.750 18 250 j 273.0 55 12 , 12.750 19 300 323.9 5.8 A 10.81 5662 Rev F Updated 11/2014 C 2014 Victaulic Company.All rights reserved. victaulic.com 4ictauluC. victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: C1,values for flow of water at+60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C„values Formulas for Kv values AP=Q2/C„2 Where: AP=Q-/K2 Where: Floss Coefficient C Flow Factor K Q=C,xVAP Q=K,xVAP C(Flew) GPM (Flow) m3/hr 11P(Pressure Drop) psi P(Pressure) bar Valve Size Full Open Valve Size Full Open Actual Actual Nominal Outside Nominal Outside Size Diameter Flow Coefficient Size Diameter Flow Coefficient inches inches C, inches inches I(• mm mm mm mm 2 2.375 170 2 i' 2.375 147 50 60.3 50 60.3 21/ 2.875 21 2.875 65 73.0 260 65 73.0 225 3.000 3.000 76.1 mm 76.1 260 76.1 mm 76.1 225 3 3.500440 j j 3 3.500 i 80 88.9 80 88.9 380 4 4.500 820 4 4.500 710 --- 100 114.3 100114.3 108mm 108mm 820 { 108mm710 � 108mm 5 i 5.563 1200 5 5.563 1040 125 141.3 125 141.3 133mm 133mm 1200 133 mm 133 mm , 1040 139.7 mm 5.500 1200 139 7 mm 5.500 1040 139.7 139.7 6 6.6251800 i 6 I 6.625 1560 150 168.3 150 168.3 159 mm 159 mm 1800 159 mm 159 mm 1560 165.1 mm 6.500 65 1800 165.1 mm 6 500 l , 165.1 1560 8 i 8.625 3400 I 8 8.625 200 i 219.1 200 219.1 2940 10 10.750 10 10.750 5800 5020 250 273.0 250 273.0 12 12.750 12 12.750 9000 7790 300 323.9 300 323.9 Z • 10.81 5662 Rev F Updated 11/2014 ©2014 Vlctaullc Company.All rights reserved. victaulic.com 5 ictauliC° victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Switch and Wiring: �T, • 1. The supervisory switch contains two single pole, L _......._ 'ire double throw, pre-wired switches. F '�� b ' Ifl NB :,,cure-.r,-T-.o �1 2. Switches are rated: f 1 :•F[IRT.: 10 amps© 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC I IV°>L>rul TJ CNDa:=-.M RCiFiP. 0.25 amps @ 250 VDC Ri:LV>VIL RI, rC A.Ct SR" CF}PT 3. Switches supervise the valve in the "OPEN" position. :.M;, _. _ & COI-AC-n i "T 25 Aer, _. AND 5. One switch has two#18 insulated wires per terminal, 51°-r. gat.<li'ADC which permit complete supervision of leads(refer `5 PT 25"° ecu , tlll� IIID IIIIII - to diagrams and notes below). The second switch AL-�P9INKr• ' has one#18 insulated wire per terminal. This double sm.,:zl.ad.P..r..nal • 5.1.11.1 bac w.t*&.l circuit provides flexibility to operate two electrical • devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve NOTE: The above diagram shows a connection between is installed. the common terminal (yellow—S1 and yellow-with- orange stripe—S2)and the normally closed terminal 6. A#14 insulated ground lead (green) is provided. (blue—S1 and blue-with-orange stripe—S2). In this Switch #1 =Sl example,the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the For connection to the supervisory circuit of a UL indicator light and alarm will go out. Cap off any unused Listed alarm control panel wires (e.g. brown with orange stripe). Switch #2=S2 Only S1 (two leads per terminal) may be connected to Auxiliary switch that may be connected to auxiliary the fire alarm control panel. devices, per the authority having jurisdiction The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per Normally Closed: (2) Blue NFPA 70(NEC). si Common: (2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe A. • Installation Note Reference should always be made to the I.5 III: •-.II-F Ir Ir II•I.r r I- r I s',4 for This product shall be manufactured by Victaulic or to Victautic.specifications,All products the product you are installing,Handbooks are Included with each shipments Victaullc to be installed in accordance with current Vlctaulic installation/assembly Instructions. products for complete installation and assembly data,and are available In PDF format Victaullc reserves the right to change product specifications,designs and standard on our website at www,victaullc.com, equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaullc for details. Victaullc'is a registered trademark of Victaullc Company. • 10.81 5662 Rev F Updated 11/2014 C 2014 Victaullc Company.All rights reserved. victaulic.com 6 jctaulic° Pipe Hangers Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) c VL us Fig.200C - "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) USTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" 115mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications air Vio Function: For fire sprinkler and other general piping purposes. Knurled --swivel nut design permits hanger adjustment after installation. Features: v • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe ta.� types and protect CPVC plastic pipe from abrasion. Captured design v keeps adjusting nut from separating with hanger. Hanger is easily B i installed around pipe. A /' For han (• ger with non-captured nut order Fig. 200S. �, • (21/2" (65m)thru 8" (2oomm))Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (20omm)) Fig Zoo-t/x 200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (2oomm))• Fig.200-1 to 200-2 Fig.200-21/z to 200-8 Conforms to Federal Specifications WtN-H-171 E&A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, 01E„ Type 10. Maximum Temperature: 650°F(343-C) Finish: Pre-Galvanized. Stainless Steel -'-'_ materials will be supplied with (2) hex nuts - ••` / in place of a knurl nut. j Order By: Figure number and pipe size Designed to meet or exceed requirements of - FM DS 2-0. 1 41616.-4 Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) .74 -\. 200-1/2 1/2" (15) 3/8'"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) ; 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) ' t • 200-1 1" (25) 3/e"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) n i • • • 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 4 200-11/2 11/2" 140) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) t 4 i1 r. • 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" 165) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 0/465:4-. 200-3 3" (75) 3/s'-16 57/s" (149.1) 4" (101.6) 29 (13.3) Fig,200S 200-31/2 31/2" (90) 3/s"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 8 200-4 4" (100) 3/a"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (1251 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (2001 1/2"-13 131/8" (333.4) 83/4" (2222) 136 (62.3) all dimenslons.n charts and on diawings are in inches.Dimensions snowr,in parentheses are in millimeters unless otherwise specified. R Fire Protection Solutions B-Line 21 by E:t•N Threaded Accessories B3205 -Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L -Threaded Rod (right& left hand threads) n > ) Size Range: 3/8"-16 thru 3"-4 rod Specify Length Material: Steel Function: Recommended for use s a hanger support in hanger aRvailable with d is left dd on �right handh ends iththreadsh specify threads of the B3205L when orderth ing.Also -4)l\�11�111 P fY 9g a Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 3,40ori-i XL 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 1/2OL. y ° 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 63205 a x`$ 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3i4411,--- 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/BL' " 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 03205-1 x'L' , 1''-8 4" (101.6) 5900 (2624) 4620 (20.55) .83205 11/8 X`L` . 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-1114x'L' '= 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) 1#0,57111,011 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B320504'1.' f 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 63205-2 x'L' x 2%41/2 8" (203.2) 24600 (109.42) 19625 (87.29) '13320541141'Lk 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) .8320541/2110-,(: ' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4x'1'• : 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 83205-3 X'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) 1��a� Fig.99- All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length 7,,,,,�) Material: Steel ''` N _ Maximum Temperature: 750°F(399°C) c Finish: Plain.Contact B-Line for alternative finishes and materials. ,. 0 m I - Order By: Part number, rod diameter and finish /"' 1- o a C Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) A1B1,4"X12Q 599'I.iii. lt'ng1ti_ 20 240 (1.07) 12 (5.44) • ;4TR 3/8"x 12(1,, -09-3-10:*** 16 730 (3.24) 29 (13.15) • -TR 112"-x 120 99-''/2"x iiigth: 13 1350 (6.00) 53 (24.04) A s/8":).,,149-J- 9918x len .h__ 11 2160 (9.60) 89 (40.37) 4A17,40-1.X'(2(1 F. `l',91014.7-400.0: 10 3230 (14.37) 123 (55.79) .:';::',4):10,07104L. 99 7/s".x length 9 4480 (19.93) 170 (77.11) 'i ATR,1"x 120'1 ' 99-1".X length,: 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B Pipe Hangers&Supports Revised 4 28/201-1y Efr. e 236b by :TN VERTICAL MOUNT SAMMYS SAMMYS® for Wood Not less than Wood Fkroring Product Features 2'nominal width (1-112') ♦.a. •No pre-drilling required. Not less than ) •Quick to install using the Sammy 3°nominal > thickness(2-1/7) Nut Driver with an 18V cordless (depth or side Wood Joist drillidriver. 1 of vertical member) •Saves time from traditional Double Sheetrock ,i methods. For vertical use- Ceilinginstall in center of lower face. ` •Reduces installation cost. Minimum 2-embedment Into base material for NFPA 13 compliance. Composite I Truss •Made inthe USA. Consult truss manufacturer for recommended inatallation point. `Pre-drilling may be required for GST ;t } 25-380.Tool available on page 10. _..... _ . 1 s Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(lbs) Load(lbs) Load(lbs) Qty Qty 210(7/16'OSB), 114 8002957 GST 100 114 X 1"- 670(314'Ply}' 25 125 1/4" 8003957 GST 200 114 x2" 1760(Fir) 25 125 1/4' 8004957 GST 300 1/4 x 3' 2060 (Fir) 25 125 3/8" 8006957 GST.75 1/4.x 3/4" 564 (3/4"Ply) 25 125 Z' ` A '3/8" 8007957 GST 10 : 1/4 x 1" 210-(7/15'OSB) 300 , 25 .125 670(3l4'Ply)' _ Q A 3/8" 8008957 GST 20 1/4x 2" 1760(Fir) 850 1475 25 125 Iiii 3/8" 8068925 GST 20-SS 1/4 x 2" 1760(Fir) 850 25 125 411 3/8" 8009925 GST 25-380 3/8 x 2-112' 2113 (Fir) 1500 25 125 42.X1' 3/8' 8010957 GST30 114x3° 2060(Fir 1500 1475= 25: 125 - #14 Black ' ) Nut Driver 3/8" 8069925 GST 30-SS 114 x 3" 2060(Fir) 25 125 Part#8113910 3/8" 8011925 GST40 1/4x4' 2180(Fir) 25 125 3/8" 8012925 GST 60 114 x 6" 2230(Fir) 25 125 — 1/2" 8013925 GST 2 1/4x2", 1760(Fir) 25 125 1/2° 8014925 GST2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 112" 8015925 GST 3 1/4 x 3" 2275(Fir) 25 125 — 1/2" 8016925 GST4 1/4x4" 2180(Fir) 25 125 1/2" 8017925', GST 6 1/4 x 6" 2230(Fir) 25' 125 #14 SW Red — Nut Driver Part#8114910 SAMMY Swivel Head"for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. "Accommodates up to 3 W x 12 pitch roof. •Reduces installation cost. 11111111 "Allows 17"deflection from vertical, •Made in the U.SA. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout(135) Load(lbs) Load(lbs) Thickness Qty Qty C%�• '318" 8139957 SH-GST 20: 1/4 x 2"' " 1257(Fir) '`' 1050 ' 1475 ' ' 25 125. 125 Q 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-of feature which provides a fast and safe installation each time.When the face of the driver comes into Nut Driver Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most tip to date I'If ol'rMile n,aisit XXX arnrnysfq,ersrrew.00m 40 OHS II�t'W�F SAMMy y HORIZONTAL MOUNT SIDEWINDERS° for Wood t Y is Not less than 2"nominal width Product Features (1-1/2")up to 3-1/2"pipe;not less than 3"(2-712')nominaaIwidth 4"&5'pipe •No pre-drilling required. Obi timometw.-_. - ' H Floor Joist •Quick to install using the Sammy Minimum 2-1/2'from bottom for branch Ilnes.Minimum 3'from Nut Driver with an 18V cordless bottom for main lines.Exception:This drill/driver. requirement shall not apply to 2"or Thicker nailing slaps resting on top of steel beams. •Saves time from traditional _ • methods. •Reduces installation cost. •Made in the USA.t • t_ • Composite/Truss Consaft truss manufacturer for , recommeroec Installaioi pant. 'Predrilling may so required for Model r SWG 25-380(boob ova!able on pg 10:t Approvals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Pullout(lbs) Load(lbs) Qty Qty 1/4' ``'8018957: SWG 100 '" .114"x 1" ' 622(Fir) " 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725(Fir) 25 125 3/8" 8020957 SWG iti 1/4-x 1" 622(Fir) 300 25 125 — al 3/8" 8021957 SWG 20 1/4 x 2" 1725(Fir) 1050 25 125 • 318" 8073925 SWG 20SS 1/4x2" 1725(Fir) ` 850 25 125 #14 SW Red Q• 3/8' 8022925 SWG 25380 3/8 x 2.1/2" 2249(Fir) 1500 25 125 Nut Driver 3/8' 8023925 SWG 30 1/4 x 3" 1884(Fir) 25 125 Part#8114910` VERTICAL HORIZONTAL 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 2.Insert the SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.When the • nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins free on the SAMMYS,stop the drill and remove. 4,The SAMMYS is now ready to receive 1/4",3/8",1/2"or metric all thread rod,bolt stock.(The 1/2"requires the#14SW red nut driver) 4.The unit is now ready to receive 1/4",3/8"or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 foot lbs.for maximum Note:When installing SWDR,follow the above instructions,then add retainer nut pullout in pudin steel. and torque to 20 foot lbs.for maximum pullout in purlin steel. ,<41,."(,:."1..A (7r , ' ,P Tikii„ 7 h . , II SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe instalabon each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.installation is then complete.Warranty requires the use of the appropriate nut driver for instalations. 5 To fend a a„trhstor r,oa',cu.c,all'DO-3UILDEX Seismic Bracing Fig. 909 - No-Thread Swivel Sway Brace Attachment ®TOLco" Size Range: 1"(25n n,)bracing pipe. For brace pipe sizes larger than CO US 1' (25111mm, use Fig.980.Available with holes for 2V8"-16 thru 3/4"-10 fastener LISTED attachment. Material: Steel, hardened cone point set bolt e Function: The structural component of a sway and seismic bracing system. m Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. 0 NFPA 13 indicates clearly that fastener table load values are based only on ca concentric loading. 'Jo threading of the bracing pipe is required. Open design -I1mi \, allows for easy inspection of pipe engagement. ' Application Note: Fig. 909 is used in conjunction with the Fig. 1000, - - Fig. 1001, Fig.4A or Fig.4L or other approved TOLCO attachment to pipe, T•' �, 1 and joined together with bracing pipe.Sway brace assemblies are intended to `: �' be installed in accordance with NFPA 13.The required type, number and size < " / D of fasteners used for the structure attachment fitting shall be in accordance • • with NFPA 13. � Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada Set Bolt A (cUL). Included B Installation Instructions: Fig.909 is the structural or transitional attachment �' component of a longitudinal or lateral sway brace assembly. It is intended to Mounting Hardware be combined with the "bracing pipe"and TOLCO'braced pipe"attachment, Is Not Included Fig. 1000, 1001, 4A, or other approved TOLCO attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig.909 onto the bracing pipe.Tighten the set bolt until the head bottoms out on surface.Attachment can pivot for adjustment ; a. to proper brace angle. Finish: Plain or Electro-Galvanized.Contact B-Line for alternative finishes and A materials. '� Order By: Figure number, fastener attachment size and finish, s Part Mounting Hole Brace Max.Design Approx Number 0 Pipe Size A B Load Wt./100 • in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 909-1/2* 17/32" (13.5) 1" (25) 6" (152.4) 15/s"(41.3) 2015 (8.96) 91 (41.3) a 909-5/8 11/16" (17.5) 1" (25) 6" (152.4) 15/8" (41.3) 2015 (8.96) 90 (40.8) 909-3/4 13/16" (20.6) 1" (25) 6" (152.4) 15/8" (41.3) 2015 (8.96) 89 (40.4) Other hole sizes are availahle, consult factory. 4' ' Standard size. Eaton's B-Line Business seismic bracing components are designed to he compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly.B-Line's warranty for seismic bracing components will he the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on aiawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 63 by ETN �•� ��I WWw.to ••'E•T' =C•' 'evision 5 / 11.1: Component of State of Fig■ 1000 - "Fast Clamp" Sway Brace Attachment California OSHPD Approved Seismic Restraints System Size Range — Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 13/4" Schedule 40 c0 us usTED IPS. *Additionally(UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 — 8 ft. lbs. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13*or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features — Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions — sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation —The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be Maximum Design Load combined with the "bracing pipe" and TOLCO structural attach- 1" thru 4" pipe size — 2015 lbs. ment component, Fig.980, 910 or 909 to form a complete bracing 6" size — 1265 lbs. assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1' extension. FM Approved Design Loads* Brace pipe can be installed on top or bottom of pipe to be braced. 1" - 21/2" - 600 lbs. Tighten hex nuts until leaf spring is flat. It is recommended that the 3" -4" - 700 lbs. brace angle be adjusted before hex nuts are fully tightened. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved by Factory Mutual Engineering(FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines.• Application Note — Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Lateral Brace TOLCO®brand bracing components are desgined to be compatible ONLY with other TOLCO5 brand bracing components,resulting in a Listed seismic bracing assembly. DISCLAIMER— NIBCO does NOT warrant against the failure of TOLCO®brand bracing components, in the instance that such TOLCOe brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under the TOLCO5 brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind,including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•t375 SAMPSON AVE.•CORONA,CA 92879•RH: 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco_com ®TOLCO' Fig. 4L Longitudinal "In-Line" Sway Brace Attachment c ® us Size Range — 2"through 8" IPS. LISTED Material — Carbon Steel .A: APPROVED Function — For bracing pipe against sway and seismic disturbance. �,� Approvals — Underwriter's Laboratories Listed in the USA(UL)and Canada(cUL)2" -8". OIL:�' �,,/ — Approved by Factory Mutual Engineering(FM),21/2"-8"pipe. i^'t Installation Instructions —The Fig.4L is the"braced pipe"attachment component of a 1 • longitudinal sway brace assembly. It is intended to be combined with the"bracing pipe"and ▪ TOLCO structural attachment component to form a complete bracing assembly.NFPA 13 ▪ and/or OSHPD guidelines should be followed. p A • To Install — Place the Fig.4L over the pipe to be braced and tighten bolts.Then engage • "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off.Jaw attachment can pivot for adjustment to proper brace angle. Finish — Plain Note —Available in Electro-Galvanized and HDG finish. C Order By— Figure number, pipe size and finish. 'y j/ .I op. N. .— ...• . t.,, I ( c-1, 'rot 0 ,__ i i , 4-Way Riser Brace I---1 ; (Plan View) i IHDimensions•Weights o Sizes Max.Rec.Load *Max.Rec. Approx. A C D Bolt Size Lbs.(cULus) Load Lbs.(FM) WtJ100 Longitudinal Brace 2 53/4 2146 2146 1'2 2015 — 247 21/2 6 7/16 21/2 2 34 / 2015 3000 253 • 3 7 2 3/4 3'-ie 1/ 2015 1550 268 i - • 4 81/2 3 3/4 311,6 1,2 2015 1550 348 • 5 9 Sia 3'/s 4 3/4 / 2015 1450 380 • • 6 111/2 5 51, S 2015 1450 640 8 131;4 5 S�a 5 3/4 1,2 2015 1450 728 L ' Load shown is allowable with brace installed, between 30` -90'. No reduction of load based on brace angle is required. FM approved when used with 1",11/4",11/"or 2"Sch.40 brace pipe Cooper B-Line, Inc.'s ("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly.Cooper B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-Line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. COOPER B-LINE 1375 Sampson Ave•Corona,CA 92879•800.786.5266•FAX:951.737.0330 www.tolco.com COOPER B-Line Schedule 10/ Schedule 40 - M-COAT® Submittal Data Sheet Fully Listed and FM Approved Sprinkler Pipe Sch-40 ASTM A135/A795 M-COAT Specifications When you specify Schedule-10/Schedule-40-M-COATriFi sprinkler pipe from NPS Nominal Nominal LD. Nominal Wt. Wt.(H20 Filled) CRR In;mm 00.In;mm In:mm Wall In;mm Lbs/Ft;kg/m Lbs/Ft;kq/m Allied Tube&Conduit,you aet UL listed and FM approved products.Although ! , 1.315 1.049 0 133 1680 205 , these products do not require separate approvals,Schedule-10/Schedule-40- 25 33.4 26.6 3.382.5 3.05 - ` M-COAT gives you the extra quality assurance you demand.Our Sch-10(1-1/4"` 1'/' 1.660 1.380 0140 2.270 2.93 1 32 42.1 4.36 -8")pipe and SCh-40(1 "-2-1/2")pipe have passed the same tholoU h lab ,/• 1.000 1.610 0.145 2.720 - 3.61 1 w testing as our other listed pipe products,and receive periodic mill inspections 40 48.3 40.9 3.68 4.0 5.37 - 2" 2.375 2.067 0.154 3.656 5.13 1 from both UL and FM agents to ensure consistent quality. 50 60.3 52.5 3.91 5.4 7.63 2'/" 2.875 2.469 0.203 5.80 7.86 1 O Superior Coating 65 73 62.7 5.16 8.6 11.73 Our advanced formula mill coating offers a clean,durable surface that is also Sch-10 ASTM A135/A795 i paintready for custom color applications without special preparation. M-COAT Specifications NPS Nominal Nominal I.D. Nominal Wt. Wt.(H20 Filled) CRR In;mm 0.D.In:mm In;mm Wall In;mm Lbs/Ft;kg/m Lbs/Ft;kglm The internal surface of all black Fire Spunkier pipe up to 4.5000" in diameter 11/2" 1.660 1.442 0.109 1.810 2.525 7.0955 shall be coated with Allied Tube&Conduit Antibacterial Formula "M-COAT". 32 42.2 36.6 2.77 2.7 3.75 11" 1.900 1.682 0.109 2.09 3.04 5.6570 40 48.3 42.7 2.77 3.1 4.52 ® American Made 2'• 2.375 2.157 0.109 2.640 4.22 4.5827 6.28 Manufactured at one of 3 U.S.Facilities and is available through distributors in 250 .8 5 54.8 2.771 3530 5.89 3.5196 the USA,Canada, Mexico,and Latin America. 65 73 66.9 3.05 5.26 8.77 3" 3.500 3.260 0.120 4.34 7.94 2.5550 75 88.9 82.8 3.05 6.4 11.82 O Specifications & Approvals 4" 4.500 4.260 0.120 5.62 11.78 1.6020 100 114.3 108.20 3.05 8.3 17.53 - Schedule-I0/Schedrile-40 M-COAT pipe are in compliance with the following: S5 141.5.563 5.295 3.40 7.78 17.33 1.4874 p 125 141.3 134.5 3.40 11.58 25.80 ASTM A135,Type E, Grade A,and hIFPA 13.Both pipe products have a working 6"' 6.625 6.357 0.134 9.3 23.03 1.0251 pressure rating of 300 psi maximum and also meet the stringent lequilement 150 168.3 161.5 3.40 13.8 34.2.7 8"' 8.625 8.249 0.188 16 96 40.15 1.8365 for the following tests:Welded Outlets, Hydrostatic Pressure,Side Wall Rupture, 200 219 209.50 4.78 25.2 59.75 Vibration Test.Test. '1101 xvailahlowilt ti-Coal 0 CO APPROVED • .1 1 4 Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: K Customer Service: (800)882-5543 Fax: (800)659-7730 www.alliedtube-sprinkler.com 9 allied 16100 S LathropAve TUBE&CONDUIT • 11350 Norcom Rd. • 2525 N 27th Ave. Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 .PAM U_AatkOre ©2013 Atkore International, Inc.All Rights Reserved.STP-S3-4M-1301