Plans (3)BUP2014 00240
(0'-3"
ADJUST. -
SHELVES
(TYP.)
PAM c—==
UNDERCABINET
FLUORESCENT
FIXTURE
PJ -AM n
WIRE PULLS
P.LAM
PROVIDE REQUIRED
PIPE INSULATION
PROVIDE INTEGRAL
TOE KICK
2 BREAK ROOM
_ 1/2"-- 1'-0"
GENERAL NOTES
30" MIN,
I
TENANT'S
REFRIGERATOR
20 GA. 3!/s" METAL STUD BRACING TO
ROOF STRUCTURE AT S'-0" O.C.
ALTERNATING DIRECTIONS. FASTEN
BRACE TO TOP OF STUD W/(2) 08
SHEET METAL SCREWS AT EACH END.
BRACING TO BE PROVIDED WHERE
DISTANCE BETWEEN PERPENDICULAR
INTERSECTING WALLS OR HORIZONTAL
BRACING BETWEEN WALLS EXCEEDS
V-01, O.C.
SUSPENDED CEILING
ATTACH BRACE DIRECTLY
TO STUD.
Ne," GYP. BD. EA. SIDE
31/2" 25 GA METAL
STUD AT 2'-0" O.C.
)TTOM TRACK TO FINISH
OCR WITH POWDER
ZIVEN ANCHORS a 2'-0" O.G.
>NCRETE SLAB.
TYP. WALL DETAIL
_ 11/211= 1'-011
I. THESE PLANS FOR TENANT IMPROVEMENT ONLY.
2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE,
PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST
TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF
THE PROJECT IN COMPLIANCE WITH THE APPLICABLE
GOVERNING BUILDING CODES AND REGULATIONS. WHERE
MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND
SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT 15 THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC
MATERIALS AND DETERMINE CONSTRUCTION DETAILING,
ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES,
REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS
AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO A55URE THAT ALL CONSTRUCTION IS IN
COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS.
3_ THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL
MEANS, METHODS, TECHNIQUES AND SEQUENCES OF
CONSTRUCTION INCLUDING JOB SITE SAFETY. THE
ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS,
METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION
INCLUDING JOB SITE SAFETY.
4, THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE
ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT,
AND SERVICES NECESSARY FOR AND REASONABLY
INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION
WORK IN CONNECTION WITH THE DOCUMENTS.
5, APPLICABLE CODES ON MATERIALS AND WORKMANSHIP
SHALL CONFORM TO THE 2014 OREGON STRUCTURAL
SPECIALTY CODE AND APPLICABLE STATE AND FEDERAL
SAFETY ORDERS. ALL REFERENCES TO CODES,
SPECIFICATIONS, AND STANDARDS SHALL MEAN AND ARE
INTENDED TO BE THE LATEST EDITION, AMENDMENT
AND/OR REVISION OF SUCH REFERENCE STANDARD IN
EFFECT.
6. EACH SUB -CONTRACTOR COR THE GENERAL CONTRACTOR
WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE
WORK) 15 CONSIDERED A SPECIALIST IN PIS RESPECTIVE
FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK,
NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF
ANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE
THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT
MEET CURRENT LOCAL BUILDING CODES.
Z. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL
DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE
DRAWING5 AND SPECIFICATIONS A5 WELL AS THE
PHYSICAL CONDITIONS OF THE SITE. NOTIFY THE
ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK
8, DIMENSIONS ARE FROM FACE OF FINISH MATERIAL.
a PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY
NEW WORK TO EXISTING CONDITION OR NEW CONDITION,
WHICHEVER IS APPROPRIATE.
IO.EACH SUB -CONTRACTOR MUST REFER TO DIAGRAMMATIC
PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK
WITH ALL TRADES TO AVOID CONFLICTS_
I1. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF
SECTION 10043 - OREGON STRUCTURAL SPECIALTY CODE
AND SHALL BE EITHER A LEVER OR PANIC TYPE
REQUIRING ONLY A SINGLE MOTION TO OPEN. KEY -LOCKING
HARDWARE MAY BE USED ON THE MAIN DOOR OF B, F, M
ORS OCCUPANCIES ONLY, WITH THE UNLOCKED DOOR
FREE TO SWING WITHOUT OPERATION OF ANY LATCHING
DEVICE AND A READILY VISIBLE DURABLE SIGN POSTED
ON THE EGRESS SIDE IMMEDIATELY ABOVE THE DOOR
STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING
15 OCCUPIED". THE SIGN SPALL BE IN LETTERS I" HIGH ON
CONTRASTING BACKGROUND.
12, PROVIDE TEMPERED GLAZING AT WINDOWS E RELIGHTS
PER SECTION 2406 - OREGON STRUCTURAL SPECIALTY
CODE, TOP OF RELIGHT FRAMES TO MATCH TOP OF DOOR
FRAMES.
13. VERIFY KEYING REQUIREMENTS WITH TENANT AND
LANDLORD.
14. PROVIDE 31/2" UNFACED BATT INSULATION AT ALL NEW
WALLS.
15. PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE
MARSHALL AT WALK-THROUGH.
16.PROvIDE HVAC W/20 CFM OUTSIDE AIR PER OCCUPANT AT
OFFICE AREA5.
11. MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE
PERMITS.
18. CABINETS TO BE OF 3/4" MELAMINE CONSTRUCTION.
EUROPEAN CONSTRUCTION (NO FACE FRAMES) ALL
EXPOSED EDGES TO HAVE EDGE BANDING. PROVIDE
BLUM -15M5580 CONCEALED 125' HINGES AND BLUM 3/4
EXTENSION DRAWER SLIDES. 100 LB RATING AT FILE
DRAWERS, 50 LB RATING AT ALL OTHER DRAWERS. BACK
SPLASHES AT COUNTER TOPS TO BE CONSTRUCTED OF 3/4"
MATERIAL. ALL EXPOSED SURFACES TO BE COVERED
WITH P.LAM. SUBMITTAL REQUIRED.
REFLECTED CEILING PLAN
1/4" = I'-0..
3RD FLOOR PLAN KEY PLAN
NOT TO SCALE
NORTH
13041 NT
304
TREATMENT
303
m
C T ION
302
TREATMENT
305
AL
3RD FLOOR PLAN
1/4"
NORTH
LEGEND
F- —-
-�
NEW SINK
A
30�
WAITING
30 OLF.. 15
146 SF. / 15
- 10 OCCUR
X-:
OFFICE
309 I O.L.F. 100
90 SF. / 100
I OCCUP.
CODE SUMMARY
GENERAL BUILDING DESCRIPTION. GENERAL OFFICE
NUMBER OF STORIES: 3
FIRE SPRINKLERS= NONE
OCCUPANCY: B
CONSTRUCTION TYPE= III -B
TENANT SPACE SIZE: 940 U.S.F.t
EXISTING WALL TO REMAIN
EXISTING HVAC DEFUSER
" --` , '"- "'-' EXISTING WALL TO BE REMOVED
NEW WALL - 31/2" METAL STUDS
24" O.C. 5/8" GYP. BD. EACH SIDE EXISTING HVAC RETURN
TO UNDERSIDE OF T -BAR CEILING
EXISTING 2X4 FLUORESCENT
FIXTURE WITH ACRYLIC LENS
EXISTING DOOR TO REMAIN TO REMAIN
i EXISTING 2X4 FLUORESCENT
FIXTURE TO BE REMOVED
rN/R NEW OR RELOCATED DOOR RELOCATED 2X4 FLUORESCENT
3'-0"x-1'-0" U.ON. FIXTURE
-n EXISTING 2X4 FLUORESCENT
j 11 FIXTURE WITH EGG CRATE LENS / I
�, II DOOR TO BE REMOVED OR TO REMAIN �(�'
RELOCATED
FO
n l
NEIU❑ NEW EXHAUST FAN
E EXISTING DUPLEX ELECTRICAL
y� OUTLET NOTE; HVAC DEFU5ER5 t RETURNS SHOWN ONLY
IN EXISTING LOCATIONS FOR CONTRACTORS
NEW DUPLEX ELECTRICAL CONVENIENCE. DEFUSERS t RETURNS
OUTLET_ BOTTOM OF COVER TO SATISFY BUIL�I��iAKl)
PLATE TO BE AT 15" AFF.
.E EXISTING MUDRING AND PULL REVIEWED FOR CODE COMPLIANCE
WIRE Approved:
[ 1a�
NEW MUDRING AND PULL WIRE OTC:
FOR TENANT PROVIDED PHONE Permit##:
v AND DATA WIRING. BOTTOM OF Address: q7�
COVER PLATE TO BE AT 15" AFF.
Suite #:
By: Data (0
�(4Ac7—
OFFICE COPY
V)
U
H
U1
O O cv
C z
Uz O
�W�oo
z Q� Q
�
cj
(P
No am MI.
05A #14053
A-1
I of= 1