Loading...
Plans (3)BUP2014 00240 (0'-3" ADJUST. - SHELVES (TYP.) PAM c—== UNDERCABINET FLUORESCENT FIXTURE PJ -AM n WIRE PULLS P.LAM PROVIDE REQUIRED PIPE INSULATION PROVIDE INTEGRAL TOE KICK 2 BREAK ROOM _ 1/2"-- 1'-0" GENERAL NOTES 30" MIN, I TENANT'S REFRIGERATOR 20 GA. 3!/s" METAL STUD BRACING TO ROOF STRUCTURE AT S'-0" O.C. ALTERNATING DIRECTIONS. FASTEN BRACE TO TOP OF STUD W/(2) 08 SHEET METAL SCREWS AT EACH END. BRACING TO BE PROVIDED WHERE DISTANCE BETWEEN PERPENDICULAR INTERSECTING WALLS OR HORIZONTAL BRACING BETWEEN WALLS EXCEEDS V-01, O.C. SUSPENDED CEILING ATTACH BRACE DIRECTLY TO STUD. Ne," GYP. BD. EA. SIDE 31/2" 25 GA METAL STUD AT 2'-0" O.C. )TTOM TRACK TO FINISH OCR WITH POWDER ZIVEN ANCHORS a 2'-0" O.G. >NCRETE SLAB. TYP. WALL DETAIL _ 11/211= 1'-011 I. THESE PLANS FOR TENANT IMPROVEMENT ONLY. 2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF THE PROJECT IN COMPLIANCE WITH THE APPLICABLE GOVERNING BUILDING CODES AND REGULATIONS. WHERE MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT 15 THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC MATERIALS AND DETERMINE CONSTRUCTION DETAILING, ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO A55URE THAT ALL CONSTRUCTION IS IN COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. 3_ THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS, TECHNIQUES AND SEQUENCES OF CONSTRUCTION INCLUDING JOB SITE SAFETY. THE ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION INCLUDING JOB SITE SAFETY. 4, THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT, AND SERVICES NECESSARY FOR AND REASONABLY INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION WORK IN CONNECTION WITH THE DOCUMENTS. 5, APPLICABLE CODES ON MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE AND APPLICABLE STATE AND FEDERAL SAFETY ORDERS. ALL REFERENCES TO CODES, SPECIFICATIONS, AND STANDARDS SHALL MEAN AND ARE INTENDED TO BE THE LATEST EDITION, AMENDMENT AND/OR REVISION OF SUCH REFERENCE STANDARD IN EFFECT. 6. EACH SUB -CONTRACTOR COR THE GENERAL CONTRACTOR WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE WORK) 15 CONSIDERED A SPECIALIST IN PIS RESPECTIVE FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF ANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT MEET CURRENT LOCAL BUILDING CODES. Z. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE DRAWING5 AND SPECIFICATIONS A5 WELL AS THE PHYSICAL CONDITIONS OF THE SITE. NOTIFY THE ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK 8, DIMENSIONS ARE FROM FACE OF FINISH MATERIAL. a PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY NEW WORK TO EXISTING CONDITION OR NEW CONDITION, WHICHEVER IS APPROPRIATE. IO.EACH SUB -CONTRACTOR MUST REFER TO DIAGRAMMATIC PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK WITH ALL TRADES TO AVOID CONFLICTS_ I1. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF SECTION 10043 - OREGON STRUCTURAL SPECIALTY CODE AND SHALL BE EITHER A LEVER OR PANIC TYPE REQUIRING ONLY A SINGLE MOTION TO OPEN. KEY -LOCKING HARDWARE MAY BE USED ON THE MAIN DOOR OF B, F, M ORS OCCUPANCIES ONLY, WITH THE UNLOCKED DOOR FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE AND A READILY VISIBLE DURABLE SIGN POSTED ON THE EGRESS SIDE IMMEDIATELY ABOVE THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING 15 OCCUPIED". THE SIGN SPALL BE IN LETTERS I" HIGH ON CONTRASTING BACKGROUND. 12, PROVIDE TEMPERED GLAZING AT WINDOWS E RELIGHTS PER SECTION 2406 - OREGON STRUCTURAL SPECIALTY CODE, TOP OF RELIGHT FRAMES TO MATCH TOP OF DOOR FRAMES. 13. VERIFY KEYING REQUIREMENTS WITH TENANT AND LANDLORD. 14. PROVIDE 31/2" UNFACED BATT INSULATION AT ALL NEW WALLS. 15. PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE MARSHALL AT WALK-THROUGH. 16.PROvIDE HVAC W/20 CFM OUTSIDE AIR PER OCCUPANT AT OFFICE AREA5. 11. MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE PERMITS. 18. CABINETS TO BE OF 3/4" MELAMINE CONSTRUCTION. EUROPEAN CONSTRUCTION (NO FACE FRAMES) ALL EXPOSED EDGES TO HAVE EDGE BANDING. PROVIDE BLUM -15M5580 CONCEALED 125' HINGES AND BLUM 3/4 EXTENSION DRAWER SLIDES. 100 LB RATING AT FILE DRAWERS, 50 LB RATING AT ALL OTHER DRAWERS. BACK SPLASHES AT COUNTER TOPS TO BE CONSTRUCTED OF 3/4" MATERIAL. ALL EXPOSED SURFACES TO BE COVERED WITH P.LAM. SUBMITTAL REQUIRED. REFLECTED CEILING PLAN 1/4" = I'-0.. 3RD FLOOR PLAN KEY PLAN NOT TO SCALE NORTH 13041 NT 304 TREATMENT 303 m C T ION 302 TREATMENT 305 AL 3RD FLOOR PLAN 1/4" NORTH LEGEND F- —- -� NEW SINK A 30� WAITING 30 OLF.. 15 146 SF. / 15 - 10 OCCUR X-: OFFICE 309 I O.L.F. 100 90 SF. / 100 I OCCUP. CODE SUMMARY GENERAL BUILDING DESCRIPTION. GENERAL OFFICE NUMBER OF STORIES: 3 FIRE SPRINKLERS= NONE OCCUPANCY: B CONSTRUCTION TYPE= III -B TENANT SPACE SIZE: 940 U.S.F.t EXISTING WALL TO REMAIN EXISTING HVAC DEFUSER " --` , '"- "'-' EXISTING WALL TO BE REMOVED NEW WALL - 31/2" METAL STUDS 24" O.C. 5/8" GYP. BD. EACH SIDE EXISTING HVAC RETURN TO UNDERSIDE OF T -BAR CEILING EXISTING 2X4 FLUORESCENT FIXTURE WITH ACRYLIC LENS EXISTING DOOR TO REMAIN TO REMAIN i EXISTING 2X4 FLUORESCENT FIXTURE TO BE REMOVED rN/R NEW OR RELOCATED DOOR RELOCATED 2X4 FLUORESCENT 3'-0"x-1'-0" U.ON. FIXTURE -n EXISTING 2X4 FLUORESCENT j 11 FIXTURE WITH EGG CRATE LENS / I �, II DOOR TO BE REMOVED OR TO REMAIN �(�' RELOCATED FO n l NEIU❑ NEW EXHAUST FAN E EXISTING DUPLEX ELECTRICAL y� OUTLET NOTE; HVAC DEFU5ER5 t RETURNS SHOWN ONLY IN EXISTING LOCATIONS FOR CONTRACTORS NEW DUPLEX ELECTRICAL CONVENIENCE. DEFUSERS t RETURNS OUTLET_ BOTTOM OF COVER TO SATISFY BUIL�I��iAKl) PLATE TO BE AT 15" AFF. .E EXISTING MUDRING AND PULL REVIEWED FOR CODE COMPLIANCE WIRE Approved: [ 1a� NEW MUDRING AND PULL WIRE OTC: FOR TENANT PROVIDED PHONE Permit##: v AND DATA WIRING. BOTTOM OF Address: q7� COVER PLATE TO BE AT 15" AFF. Suite #: By: Data (0 �(4Ac7— OFFICE COPY V) U H U1 O O cv C z Uz O �W�oo z Q� Q � cj (P No am MI. 05A #14053 A-1 I of= 1