Plans (4)BUP2013-00283 1 T11 1/8"=11-00 l�r1tl►t/lAl D A TU nC' NWCUA TRIANGLE III 13221 SW 68TH PARKWAY 19 pxlej I 9M INDEX OF DRAWINGS TIA PARTIAL FOURTH FLOOR DEMOLITION PLAN, CODE SUMMARY PLAN, PROJECT INFORMATION AND NOTES A2.1 PARTIAL FOURTH FLOOR PLAN, REFLECTED CEILING PLAN AND NOTES A5.1 DETAILS AND ELEVATIONS A8.1 DETAILS AND ELEVATIONS A9.1 SCHEDULES SCOPE OF WORK THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS FOR AN APPROXIMATLEY 3,214 SQUARE FOOT TENANT ON THE FOURTH OF FIVE FLOORS. WORK TO INCLUDE DEMOLITION, NEW DOORS, WALLS, RELITES, AND CABINETRY. TENANT APPROVAL DESIGN/CODE DATA GOVERNING CODE: 2010 OSSC OCCUPANCY. B CONSTRUCTION TYPE. TYPE I --B TENANT AREA (APPROX): 3,214 S.F. OCCUPANCY LOAD: 33 ONE REQUIRED EXIT, ONE EXIT PROVIDED ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION THROUGHOUT WITH ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER (s Ikv NORTH "21 CODE _SUMMARY PLAN T1.1 l 1/16"=1'-0" LEGEND == =_= EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING WALL TO REMAIN ;i EXIT REQUIRED EXIT NOT IN SCOPE OF WORK EXISTING i HOUR RATED WALL TO REMAIN EXISTING 2 HOUR RATED WALL TO REMAIN EXISTING DEMISING WALL TO REMAIN DEMOLISHED OUTLET AND TELEPHONE/DATA DEMOLISHED BASE FEED DEMOLISHED THERMOSTAT U NO = �C�-u; � I pl: �; 9: U M 4 -01 M OWD ILM 2010 OSSC SECTION 107.3.4.2 FIRE SPRINKLER & ALARM MECHANICAL ELECTRICAL PLUMBING EXIT ILLUMINATION (by separate permit) NOTE. DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS - ARE SCHEMATIC ONLY. THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW PRIOR TO SUBMITTAL ADA IMPROVEMENTS VALUATION OF WORK = $100,000 25% VALUATION FOR UPGRADE _ $25,000 ADA UPGRADE = NEW ADA COMPLIANT CABINETRY A. PATCH AND REPAIR EXISTING CONDITIONS WHERE AFFECTED BY DEMOLITION. SEE SHEET A9.1 FOR FINISHES. B. THE CONTRACTOR SHALL CAREFULLY EXAMINE CONSTRUCTION DOCUMENTS FOR THE WORK. ANY CONFLICTS, INCLUDING BUT NOT LIMITED TO BUILT CONDITIONS OF M.E.P. IN THE PLANS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT/DESIGNER, SO THAT THE CLARIFICATION CAN BE ISSUED. c. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO LANDLORD FOR FUTURE USE. D. SAVE AND RECYCLE DEMOLITION DEBRIS WHERE POSSIBLE. COORDINATE WITH CITY OF TIGARD REQUIREMENTS FOR RECYCLING DEMOLITION DEBRIS. KEYNOTES 1. REMOVE EXISTING STONE TILE FLOORING. CLEAN AND PREP SUBSTRATE FOR NEW VINYL PLANK FLOORING. SALVAGE FOR FUTURE LANDLORD USE IF FEASIBLE, COORDINATE WITH LANDLORD. Architecture ® Interiors Planning a Engineering Portland, OR 503.224.9560 Vancouver, WA 360.695.7879 Seattle, WA 206.749.9993 www.mcknze.com MACKENZIE. DESIGN DRIVEN 1 CLIENT FOCUSED Client Project NWCUA TENANT IMPROVEMENT SUITE 410 TRIANGLE III 13221 SW 6M PARKWAY TV", OR 97223 ,iQ41 ;ALTO y ORTLAND, OREGON Q3 CITY OF TIGARD OF Approved ...........II ............... C Conditionally Approved .............. [O MACKENZIE 2013 See Letter to: Follow .................. [ ) ALL RIGHTS RESERVED Attached ............... [ ] THESE DRAWINGS ARE THE PROPERTY Permit Number. a)P2013-Cn ZaS3 OF MACKENZIE AND ARE NOT TO BE Addres : ZZ-- USED OR REPRODUCED IN ANY MANNER, Y/Cl WITHOUT PRIOR WRITTEN PERMISSION By: Date: C REVISIONS: Approved platns o shall be on O sitV,< REVISIONS REVISION DELTA j S-1 THIS CLOSING DATE r - o SHEET OFFICE COPY V v 3� l TRIANGLE CORPORATE PARK - BUILDING III SHEET TITLE: DEMOLITION PLAN, CODE SUMMARY PLAN, PROJECT INFORMATION AND NOTES DRAWN BY: LJC CHECKED BY: LFI, PPA SHEET: T1.1 JOB NO*2080243.29 BID/PERMIT SET: 11/14/13 208024329\ARCH\29-T1.1.DWG JAC 11/14/13 09:52 1:96.00