INDEX OF DRAWINGS
TIA PARTIAL FOURTH FLOOR DEMOLITION PLAN, CODE SUMMARY PLAN, PROJECT
INFORMATION AND NOTES
A2.1 PARTIAL FOURTH FLOOR PLAN, REFLECTED CEILING PLAN AND NOTES
A5.1 DETAILS AND ELEVATIONS
A8.1 DETAILS AND ELEVATIONS
A9.1 SCHEDULES
SCOPE OF WORK
THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS FOR AN
APPROXIMATLEY 3,214 SQUARE FOOT TENANT ON THE FOURTH OF FIVE FLOORS. WORK TO
INCLUDE DEMOLITION, NEW DOORS, WALLS, RELITES, AND CABINETRY.
TENANT APPROVAL
DESIGN/CODE DATA
GOVERNING CODE:
2010 OSSC
OCCUPANCY.
B
CONSTRUCTION TYPE.
TYPE I --B
TENANT AREA (APPROX):
3,214 S.F.
OCCUPANCY LOAD:
33
ONE REQUIRED EXIT, ONE EXIT PROVIDED
ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE
BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION THROUGHOUT
WITH ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER
(s
Ikv
NORTH
"21 CODE _SUMMARY PLAN
T1.1 l 1/16"=1'-0"
LEGEND
== =_= EXISTING CONSTRUCTION TO BE DEMOLISHED
EXISTING WALL TO REMAIN
;i
EXIT REQUIRED EXIT
NOT IN SCOPE OF WORK
EXISTING i HOUR RATED WALL TO REMAIN
EXISTING 2 HOUR RATED WALL TO REMAIN
EXISTING DEMISING WALL TO REMAIN
DEMOLISHED
OUTLET AND TELEPHONE/DATA
DEMOLISHED
BASE FEED
DEMOLISHED
THERMOSTAT
U NO = �C�-u; �
I pl: �; 9: U M 4 -01 M OWD ILM
2010 OSSC SECTION 107.3.4.2
FIRE SPRINKLER
& ALARM
MECHANICAL
ELECTRICAL
PLUMBING
EXIT ILLUMINATION
(by separate permit)
NOTE. DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN
OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS -
ARE SCHEMATIC ONLY. THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT
DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW
PRIOR TO SUBMITTAL
ADA IMPROVEMENTS
VALUATION OF WORK = $100,000
25% VALUATION FOR UPGRADE _ $25,000
ADA UPGRADE = NEW ADA COMPLIANT CABINETRY
A. PATCH AND REPAIR EXISTING CONDITIONS WHERE AFFECTED
BY DEMOLITION. SEE SHEET A9.1 FOR FINISHES.
B. THE CONTRACTOR SHALL CAREFULLY EXAMINE CONSTRUCTION
DOCUMENTS FOR THE WORK. ANY CONFLICTS, INCLUDING BUT
NOT LIMITED TO BUILT CONDITIONS OF M.E.P. IN THE PLANS
SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT/DESIGNER,
SO THAT THE CLARIFICATION CAN BE ISSUED.
c. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO
LANDLORD FOR FUTURE USE.
D. SAVE AND RECYCLE DEMOLITION DEBRIS WHERE POSSIBLE. COORDINATE
WITH CITY OF TIGARD REQUIREMENTS FOR RECYCLING DEMOLITION DEBRIS.
KEYNOTES
1. REMOVE EXISTING STONE TILE FLOORING. CLEAN AND PREP
SUBSTRATE FOR NEW VINYL PLANK FLOORING. SALVAGE FOR
FUTURE LANDLORD USE IF FEASIBLE, COORDINATE WITH
LANDLORD.
Architecture ® Interiors
Planning a Engineering
Portland, OR
503.224.9560
Vancouver, WA
360.695.7879
Seattle, WA
206.749.9993
www.mcknze.com
MACKENZIE.
DESIGN DRIVEN 1 CLIENT FOCUSED
Client
Project
NWCUA
TENANT IMPROVEMENT
SUITE 410
TRIANGLE III
13221 SW 6M PARKWAY
TV", OR 97223
,iQ41
;ALTO
y
ORTLAND, OREGON
Q3
CITY OF TIGARD
OF
Approved ...........II ............... C
Conditionally Approved .............. [O MACKENZIE 2013
See Letter to: Follow .................. [ ) ALL RIGHTS RESERVED
Attached ............... [ ] THESE DRAWINGS ARE THE PROPERTY
Permit Number. a)P2013-Cn ZaS3 OF MACKENZIE AND ARE NOT TO BE
Addres : ZZ-- USED OR REPRODUCED IN ANY MANNER,
Y/Cl WITHOUT PRIOR WRITTEN PERMISSION
By: Date: C
REVISIONS:
Approved platns o
shall be on O sitV,< REVISIONS REVISION DELTA
j S-1 THIS CLOSING DATE
r - o SHEET
OFFICE COPY
V v
3�
l
TRIANGLE
CORPORATE
PARK -
BUILDING III
SHEET TITLE:
DEMOLITION PLAN,
CODE SUMMARY
PLAN, PROJECT
INFORMATION AND
NOTES
DRAWN BY: LJC
CHECKED BY: LFI, PPA
SHEET:
T1.1
JOB NO*2080243.29
BID/PERMIT SET: 11/14/13
208024329\ARCH\29-T1.1.DWG JAC 11/14/13 09:52 1:96.00