Report (51) 1 mcC AO(Ce - ori/Cry Ci-1 Generated by COMcheck-Web Software Mechanical Compliance Certi��VED MAR 4 2016 CITY OF TIGARD Section 1: Project Information BUILDING DIVISION Energy Code:2014 Oregon Energy Efficiency Specialty Code Project Title: Project Type:Addition Construction Site: Owner/Agent: Designer/Contractor: 15954 SW 72nd Ave Gohman Mechanical,Inc. Portland,Oregon 97224 14505 SE Hwy 212 Clackamas,Oregon 97015 503-658-1892 Drew@Gohmanmechanical.com Section 2: General Information Building Location(for weather data): Tigard,Oregon Climate Zone: 4c Section 3: Mechanical Systems List Quantity System Type&Description 1 HVAC System(Unknown): Heating: 1 each-Duct Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=80.00%Ec,Required Efficiency=80.00%Ec Cooling: 1 each-Single Package DX Unit,Capacity=24 kBtu/h,Air-Cooled Condenser, Unknown Economizer Proposed Efficiency=14.00 SEER,Required Efficiency= 13.00 SEER Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Requirements Specific To: HVAC System : v 1. Equipment meets minimum efficiency: Duct Furnace(Gas): 80.00%Ec ✓ 2. Equipment meets minimum efficiency: Single Package Unit: 13.00 SEER 3. Energy recovery ventilation systems.Individual fan systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity have an energy recovery system. Exception(s): 13 Where energy recovery systems are prohibited by the International Mechanical Code. 13 Systems serving spaces that are not cooled and are heated to less than 60°F. O Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. ❑ Type 1 kitchen exhaust hoods. Cooling systems in climates with a 1-percent cooling design wet-bulb temperature less than 64°F(18°C). 13 Systems requiring dehumidification that employ series-style energy recovery coils wrapped around the cooling coil when the evaporative coil is located upstream of the exhaust air stream. ❑ Systems exhausting toxic,flammable,paint exhaust,corrosive fumes,or dust. 1p Laboratory fume hood systems that include qualifying features. Plans reference page/section: N/A Generic Requirements: Must be met by all systems to which the requirement is applicable: `/ 1. Calculation of heating and cooling loads.Design loads are determined in accordance with the procedures described in the ASHRAE/ACCA Standard 183.Alternatively,design loads have been determined by an approved equivalent computation procedure. Project Title: Report date: 03/11/16 Data filename: Page 1 of 4 1 u 2. Packaged Electric Equipment.Specified packaged electrical equipment has a heat pump as the primary heating source. Exception(s): Unstaffed equipment shelters or cabinets used solely for personal wireless service facilities. 0 Requirement is not applicable. • • Plans reference page/section: N/A ✓ 3. Cooling equipment economizers:The total capacity of all cooling equipment without economizers must be less than 240 kBtu/h.This project lists 24 kBtu/h capacity without economizers.That portion of the equipment serving dwelling units and guest rooms is not + included in determining the total capacity of units without economizers. Plans reference page/section: ✓ 4. Equipment and system sizing.Heating and cooling equipment and systems capacity do not exceed the loads calculated in accordance with Section 503.2.1. Plans reference page/section: v 5. HVAC Equipment Performance Requirements.Reported efficiencies have been tested and rated in accordance with the applicable test procedure.The efficiency has been verified through certification under an approved certification program or,if no certification program exists,the equipment efficiency ratings are supported by data furnished by the manufacturer. ✓ 6. Thermostatic Controls.The supply of heating and cooling energy to each zone is controlled by individual thermostatic controls that respond to temperature within the zone. Plans reference page/section: 7. Heat pump supplementary heat.Heat pumps having supplementary electric resistance heat have controls that,except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Plans reference page/section: N/A ✓ 8. Set point overlap restriction.Where used to control both heating and cooling,zone thermostatic controls provide a temperature range or deadband of at least 5°F(2.8°C)within which the supply of heating and cooling energy to the zone is capable of being shut off or reduced to a minimum. Plans reference page/section: ✓ 9. Optimum Start Controls.Each HVAC system has controls that vary the start-up time of the system to just meet the temperature set point at time of occupancy. Plans reference page/section: v 10.0ff-hour controls.Each zone is provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. Plans reference page/section: v 11.Shutoff damper controls.Both outdoor air supply and exhaust are equipped with not less than Class I motorized dampers. Plans reference page/section: u 12.Freeze Protection and Snow melt system controls.Freeze protection systems,such as heat tracing of outdoor piping and heat exchangers, including self-regulating heat tracing,include automatic controls capable of shutting off the systems when outdoor air temperatures meet code criteria. Plans reference page/section: N/A u 13.Separate air distribution systems.Zones with special process temperature requirements and/or humidity requirements are served by separate air distribution systems from those serving zones requiring only comfort conditions;or shall include supplementary control provisions so that the primary systems may be specifically controlled for comfort purposes only. Exception(s): D [503.2.4.8+j Zones requiring only comfort heating or comfort cooling that are served by a system primarily used for process temperature and humidity control. Plans reference page/section: N/A O 14.Humidity control.If a system is equipped with a means to add or remove moisture to maintain specific humidity levels in a zone or zones,a humidity control device is provided. Plans reference page/section: N/A O 15.Humidity control.Where a humidity control device exists it is set to prevent the use of fossil fuel or electricity to produce relative humidity in excess of 30 percent.Where a humidity control device is used for dehumidification,it is set to prevent the use of fossil fuel or electricity to reduce relative humidity below 60 percent. Project Title: Report date: 03/11/16 Data filename: Page 2 of 4 Exception(s): Li Hospitals,process needs,archives,museums,critical equipment,and other non-comfort situations with specific humidity requirements outside this range. Plans reference page/section: N/A ❑ 16.Humidity control.Where a humidity control device exists it is set to maintain a deadband of at least 10%relative humidity where no active humidification or dehumidification takes place. Exception(s): Li Heating for dehumidification is provided with heat recovery or heat pumping and the mechanical cooling system efficiency is 10 percent higher than required in section 503.2.3, HVAC equipment performance requirements. Plans reference page/section: N/A ✓ 17.Ventilation.Ventilation,either natural or mechanical,is provided in accordance with Chapter 4 of the International Mechanical Code. Where mechanical ventilation is provided,the system has the capability to reduce the outdoor air supply to the minimum required by Chapter 4 of the International Mechanical Code. Plans reference page/section: O 18.Demand controlled ventilation(DCV).DCV is required for spaces larger than 500 ft2 for simple systems and spaces larger than 150 ft2 for multiple zone systems. Exception(s): Li Systems with energy recovery complying with Section 503.2.6 0 Spaces less than 750 ft2(69.7 m2)where an occupancy sensor turns the fan off,closes the ventilation damper,or closes the zone damper when the space is unoccupied. Plans reference page/section: N/A 19.Kitchen hoods.Kitchen makeup is provided as required by the Oregon Mechanical Specialty Code. Exception(s): U Where hoods are used to exhaust ventilation air that would otherwise be exhausted by other fan systems. Li Kitchen exhaust systems that include exhaust air energy recovery complying with section 503.2.6. Plans reference page/section: N/A • 20.Enclosed parking garage ventilation controls.In Group S-2,enclosed parking garages used for storing or handling automobiles employs automatic carbon monoxide sensing devices. Plans reference page/section: N/A ✓ 21.Duct and plenum insulation and sealing.All supply and return air ducts and plenums are insulated with the specified insulation.When located within a building envelope assembly,the duct or plenum is separated from the building exterior or unconditioned or exempt spaces by a minimum of R-8 insulation.All ducts,air handlers and filter boxes are sealed.Joints and seams comply with Section 603.9 of the International Mechanical Code. ✓ 22.Low-pressure duct systems.All longitudinal and transverse joints,seams and connections of low-pressure supply and return ducts are securely fastened and sealed with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric systems or tapes installed in accordance with the manufacturer's installation instructions. Plans reference page/section: • 23.Medium-pressure duct systems.All ducts and plenums designed to operate medium-pressure are insulated and sealed in accordance with Section 503.2.7.Pressure classifications specific to the duct system are clearly indicated on the construction documents. Plans reference page/section: N/A • 24.High-pressure duct systems.Ducts designed to operate at high-pressure are insulated and sealed in accordance with Section 503.2.7. In addition,ducts and plenums are leak-tested in accordance with the SMACNA HVAC Air Duct Leakage Test Manual. Plans reference page/section: N/A ✓ 25Air system balancing. Each supply air outlet and zone terminal device is equipped with means for air balancing in accordance with the requirements of IMC 603.17.Discharge dampers intended to modulate airflow are prohibited on constant volume fans and variable volume fans with motors 10 horsepower. Plans reference page/section: ✓ 26.Manuals.The construction documents require that an operating and maintenance manual be provided to the building owner by the mechanical contractor.See long description for specifications. Plans reference page/section: ▪ 27.Air System Design and Control.Each HVAC system having a total fan system motor nameplate hp exceeding 5 hp meets the provisions of Sections 503.2.10.1 through 503.2.10.2. Project Title: Report date: 03/11/16 Data filename: Page 3 of 4 Plans reference page/section: N/A ✓ 28Allowable fan floor horsepower.Each HVAC system at fan system design conditions does not exceed the allowable fan system motor nameplate hp(Option 1)or fan system bhp(Option 2)as shown and calulated in requirement details. Plans reference page/section: ✓ 29.Motor nameplate horsepower.For each fan,the selected fan motor is no larger than the first available motor size greater than the brake horsepower(bhp). Plans reference page/section: ❑ 30.Large Volume Fan Systems.Fan systems over 8,000(7 m3/s)cfm without direct expansion cooling coils that serve single zones reduce airflow based on space thermostat heating and cooling demand.A two-speed motor or variable frequency drive reduces airflow to a maximum 60 percent of peak airflow or minimum ventilation air requirement as required by Chapter 4 of the International Mechanical Code,whichever is greater. Exception(s): ❑ Systems where the function of the supply air is for purposes other than temperature control,such as maintaining specific humidity levels or supplying an exhaust system. Plans reference page/section: N/A ❑ 31.All air-conditioning equipment and air-handling units with direct expansion cooling and a cooling capacity at ARI conditions greater than or equal to 110,000 Btu/h that serve single zones have their supply fan operation controlled according to code specific requirements. Exception(s): ❑ Systems where the function of the supply air is for purposes other than temperature control,such as maintaining specific humidity levels or supplying an exhaust system. Plans reference page/section: N/A ❑ 32.Series fan-powered terminal unit fan motors.Fan motors for series fan-powered terminal units are electronically-commutated motors and have a minimum motor efficiency of 70 percent when rated in accordance with NEMA Standard MG 1-2006 at full load rating conditions. Plans reference page/section: N/A ❑ 33.Hot Gas Bypass Limitation.For cooling systems<=240 kBtu/h,maximum hot gas bypass capacity is no more than 50%total cooling capacity. Plans reference page/section: N/A Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist. p re(4) G 0h fan C Sin,' �sS/Sict T ?S)- 3/1/1 iS Name-Title Signature Date Section 6: Post Construction Compliance Statement • HVAC record drawings of the actual installation,system capacities,calibration information,and performance data for each equipment provided to the owner. • HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. ur Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. orf 1,1,4-2 zt31 iC 7/S Principal Mechanical Designer-Name Signature Date Project Title: Report date: 03/11/16 Data filename: Page 4 of 4 • • RECEIVED ED MAR 14 2016 CITY OF - Product Data BUILDING DIA ION Single Packaged Convertible Gas/Electric 14 SEER 2-5 Ton 4YCC4024A1060A 4YCC4030A1070A 4YCC4036A1070A 4YCC4036A1090A \ 4YCC4042A1060A ('����` 7"'»>in;��01�— 4YCC4042A1090A 4YCC4048A1070A 4YCC4048A1090A \\\ 4YCC4060A1090A 4YCC4060A1115A Ir „,, \�• ,'SII /% December 2014 22-1901-1 B-EN (II1f/IngersollRand TRANS® Table of Contents Single Packaged Convertible Gas/Electric Systems 3 Optional Equipment Listing 4 Product Specifications 6 Indoor Fan Performance 11 Field Wiring Diagram 17 Wiring 18 Wiring 20 Full Perimeter Roof Mounting Curb 22 Optional Equipment — Economizer 24 Optional Equipment — Outside Air Damper 25 Optional Equipment — Filter Rack 26 Outline Drawings 27 2 22-1901-1 B-EN TRM/E® Single Packaged Convertible Gas/Electric Systems Trane offers a complete family of packaged gas/electric heating and cooling systems,designed to provide the unbeatable combination of energy efficiency and lower operating costs. In warm weather,the package gas/electric system functions as an all-electric, high efficiency air conditioner.In cold weather, it operates as a natural gas or propane gas furnace,offering the best of both energy worlds. Because cooling and heating functions are all contained in a single cabinet,a single packaged convertible gas/electric system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation.When connected to an optional American Standard thermostat control, and air distribution ducts,you have a highly efficient,total home comfort system. Single Packaged Convertible Gas/Electric Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed and manufactured for maximum service. Every compressor is designed and manufactured to exacting specifications.Each design is life tested in extreme environments to ensure reliable and long lasting operation in normal applications.Each compressor has internal motor protection for added reliability. Single Packaged Convertible Gas/Electric Systems provide better performance. Our single packaged cooling/heating units offer cooling/heating efficiencies that are unmatched in the industry and provide you with a product far superior in performance than the competition. 22-1901-1 B-EN 3 TRANE® Optional Equipment Listing *=T,W,orV Hinged Filter Access Door(4*CC4024-036)(4*CY4024-4036) BAYCCDOR1A[ ] Hinged Filter Access Door(4*CC4042-060)(4*CY4042-4060) BAYCCDOR2A[ ] Roof Curb Full Perimeter(4*CCO24-036A)(4*CY4024-4036) BAYCURB050A[ ] Roof Curb Full Perimeter(4*CC042-060A)(4*CY4042-4060) BAYCURB051A[ ] Roof Curb Utility Extension Kit(BAYCURB050A) BAYUTIL101B[ ] Roof Curb Utility Extension Kit(BAYCURB051A) BAYUTIL101B[ ] 0-25%Manual Fresh Air Damper(4*CC4024-36A)(4*CY4024-4036)(x) BAYOSAHOO1A[ ] 0-25%Manual Fresh Air Damper(4*CC4042-60A)(4*CY4042-4060)(x) BAYOSAH002A[ ] Motorized Fresh Air Damper(4*CC4024-036A)(4*CY4024-4036)(x) BAYDMPR101A[ ] Motorized Fresh Air Damper(4*CC4042-060A)(4*CY4042-4060)(x) BAYDMPR102A[ ] 16"Round Duct Adapter(2 per box)(4*CC4024-036A)(4*CY4024-4036)(b) BAYSQRD001A[ ] 18"Round Duct Adapter(2 per box)(4*CC4024-060A)(4*CY4024-4036)(b) BAYSQRD002A[ ] 0-100%Mod Economizer w/Baro.Relief(4*CC4024-036A)(4*CY4024-4036)(x)(c)(d) BAYECON 1018[ ] 0-100%Mod Economizer w/Baro.Relief(4*CC4042-060A)(4*CY4042-4060)(x)(d) BAYECON1U2B[ ] 0-1000/0 Horizontal Economizer(4*CC4024-36A)(4*CY4024-4036)(x) BAYECON200B[ ] 0-100%Horizontal Economizer(4*CC4042-60A)(4*CY4042-4060)(x) BAYECON201B[ ] Enthalpy Control for Economizer(ALL-BAYECON) BAYEENTHOO1A[ ] Remote Potentiometer(ALL-BAYECON) BAYSTAT023[ ] 1"-2"Filter Frame(4*CC4024-036A)(4*CY4024-4036)(18 x 25 filter not included) BAYFLTR101C[ ] 1"-2"Filter Frame(4*CC4042-060A)(4*CY4042-4060)(two 18 x 20 filters not included) BAYFLTR201C[ ] Head Pressure Control(Low Ambient Cool)(208/240v)Kit BAYLOAM105A[ ] Quick Start Kit(4WCC4-A1)(4TCC4-A1) BAYQSKT300A[ ] Quick Start Kit(4YCC4-A1) BAYQSKT301A[ ] Crankcase Heater Scroll(4*CC4024-036)(4*CY4024-4036)(230v) BAYCCHT103A[ ] Crankcase Heater Scroll(4*CC4042-060)(4*CY4042-4060)(230v) BAYCCHT102A[ ] Crankcase Heater Scroll(4*CC4024-036)(4*CY4024-4036)(230v) BAYCCHT301A[ ] Crankcase Heater Scroll(4*CC4042-060)(4*CY4042-4060)(230v) BAYCCHT302A[ ] Adapter Curb(4*CC4024-36A)(4*CY4024-4036A)to BAYCURB030,38 BAYADAP050A[ ] Adapter Curb(4*CC4024-36A)(4*CY4024-4036A)to BAYCURB033 BAYADAP051A[ ] Adapter Curb(4*CC4042-60A)(4*CY4042-4060A)to BAYCURB030,38 BAYADAP052A[ ] Adapter Curb(4*CC4042-60A)(4*CY4042-4060A)to BAYCURB033 BAYADAP053A[ ] Adapter Curb(4*CC4042-60A)(4*CY4042-4060A)to BAYCURB034 BAYADAP054A[ ] 12"Duct Shroud Covers Horizontal(4*CC4024-060A)(4*CY4024-4060A) BAYCOVR112A[ ] 18"Duct Shroud Covers Horizontal(4*CC4024-060A)(4*CY4042-4060A) BAYCOVR118A[ ] Extreme Condition Mounting Kit—All BAYCURB&BAYADAP BAYEXMK001A[ ] Extreme Condition Mounting Kit—All BAYUTIL BAYEXMK002B[ ] Extreme Condition Mounting Kit—All Slab Mounts BAYEXMK003B[ ] Lifting Lug Kit BAYLIFT002B[ ] LP Conversion Kit(All 115K Models) BAYLPKT100A[ ] LP Conversion Kit(All 60K and 90K Models) BAYLPKT101A[ ] LP Conversion Kit(All 70K Models) BAYLPKT102A[ ] SUPPLEMENTARY HEATERS(1 PHASE)* =T or W Only 3.76/5.0 KW Heater(208/240V 1 PH)(4*CC4024-060A1) BAYHTRV105F[ ] 6.0/8.0 KW Heater(208/240V 1 PH)(4*CC4024-060A1) BAYHTRV108F[ ] 7.50/10.0 KW Heater(208/240V 1 PH)(4*CC4024-060A1) BAYHTRV110F[ ] 11.27/15.0 KW Heater(208/240V 1 PH)(4*CC4030-060A1) BAYHTRV115F[ ] 15.0/20.0 KW Heater(208/240V 1 PH)(4*CC4048-060A1) BAYHTRV120F[ ] 18.78/25.0 KW Heater(208/240V 1 PH)(4*CC40060A1) BAYHTRV125F[ ] 4 22-1901-1B-EN • TRANE° Optional Equipment Listing SUPPLEMENTARY HEATERS(3 PHASE)* =T or W Only 3.76/5.0 KW Heater(208/240V 3 PH)(4WCY4036-060A3) BAYHTRV305F[ ] 3.76/5.0 KW Heater(208/240V 3 PH)(4WCY4036-060A3) BAYHTRV308F[ ] 7.50/10.0 KW Heater(208/240V 3 PH)(4WCY4024-048A3) BAYHTRV310F[ ] 11.27/15.0 KW Heater(208/240V 3 PH)(4WCY4036-060A3) BAYHTRV315F[ ] 15.0/20.0 KW Heater(208/240V 3 PH)(4WCY4048-060A3) BAYHTRV320F[ ] 18.78/25.0 KW Heater(208/240V 3 PH)(4WCY4048-060A1) BAYHTRV325F[ ] Single Power Entry Kit(e) BAYSPEKO6OF[ ] Single Power Entry Kit(e) BAYSPEK061E[ ] Single Power Entry Kit(e) BAYSPEK062F[ ] Single Power Entry Kit(e) BAYSPEK063F[ ] Single Power Entry Kit(e) BAYSPEK064E[ ] Single Power Entry Kit(e) BAYSPEK065E[ ] (a) Must use internal filter frame when economizer or fresh air kit is used. (b) It is the responsibility of the installing dealer to properly size the ductwork for each specific application. () Dry bulb control standard with economizer. (d) Downflow only. (e) Must be selected per unit and heater model 22-1901-1B-EN 5 TRANS Product Specifications MODEL 4YCC4024A1060A 4YCC4030A1070A 4YCC4036A1070A 4YCC4036A1090A - RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 Performance Cooling BTUH(a) 24600 28200 37000 37000 Indoor Airflow(CFM) 805 870 1190 1190 Power Input(KW) 1.99 2.39 3.08 3.08 EER/SEER(BTU/Watt-Hr.) 12.0/14.00 12.0/14.00 12.0/14.00 12.0/14.00 Sound Power Rating[dB(A)] 66.6 70.0 69.3 69.3 (b) PERFORMANCE HEATING(c) Input BTUH-1st Stage (Natural Gas)(d) 60000 70000 70000 90000 AFUE 81 81 81 81 Temp.Rise-Min/Max(°F) 30/60 30/60 30/60 35/65 Orifice Qty/Drill Sz.(Natural 2/#37 2/#33 2/#33 3/#37 Gas) POWER CONN.-V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 Min.Brch.Cir.Ampacity(e) 19.1 22.6 24.5 24.5 Fuse Size-Max.(amps) 30 35 40 40 Fuse Size-Recmd.(amps) 30 35 40 40 COMPRESSOR SCROLL SCROLL SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 R.L.Amps-L.R.Amps 12.8/58.3 14.1/73.0 15.4/83.9 15.4/83.9 OUTDOOR COIL-TYPE SPINE-FIN SPINE-FIN SPINE-FIN SPINE-FIN Rows/F.P.I 2/24 2/24 2/24 2/24 Face Area(sq.ft.) 13.32 13.32 15.49 15.49 Tube Size(in.) 3/8 3/8 3/8 3/8 INDOOR COIL-TYPE MCHE MCHE MCHE MCHE Rows/F.P.I 2/16 2/16 2/16 2/16 Face Area(sq.ft.) 2.7 2.7 2.7 2.7 Tube Size Width(in.) .81 .81 1" 1" Refrigeration Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN-TYPE SWEPT SWEPT SWEPT SWEPT DIA.(IN.) 23.4 23.4 23.4 23.4 DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 DIRECT/1 DIRECT/1 CFM @ 0.0 in.w.g.(f) 2350 2800 3080 3080 Motor-HP/R.P.M 1/12/810 1/6/825 1/5/825 1/5/825 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps .54/.82 .85/1.65 1.1/2.0 1.1/2.0 INDOOR FAN-TYPE CONSTANT TORQUE ECM CONSTANTTORQUE ECM CONSTANTTORQUE ECM CONSTANTTORQUE ECM - Dia.x Width(in.) 10.62 X 10.62 10.62 X 10.62 10.62 X 10.62 10.62 X 10.62 Drive/No.Speeds DIRECT-3 DIRECT-3 DIRECT-3 DIRECT-3 CFM @ 0.0 in.w.g.(g) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor-HP/R.P.M. 1/3/1050 1/2/1050 1/2/1050 1/2/1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 2.6 4.1 4.1 4.1 COMBUSTION FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive/No.Speeds DIRECT/1 DIRECT/1 DIRECT/1 DIRECT/1 6 22-1901-1B-EN • TRANE° Product Specifications • MODEL 4YCC4024A1060A 4YCC4030A1070A 4YCC4036A1070A 4YCC4036A1090A Motor-HP/R.P.M. 1/34/3350 1/34/3290 1/34/3290 1/34/3075 Volts/Ph/Hz 230/1/60 230/1/60 230/1/60 230/1/60 FLA .20 .20 .20 .24 FILTER/FURNiSHED NO NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY Recmd.Face Area(sq.ft)(h) 4.0 4.0 4.0 4.0 REFRIGERANT R-410 R-410 R-410 R-410 Charge(lbs.) 5.24 6.94 7.2 7.2 CHARGING SPECIFICATIONS . Subcooling 12° 11° 11° 11° GAS PIPE SIZE(in.) 1/2 1/2 1/2 1/2 DIMENSIONS HXDXW HXDXW HXDXW HXDXW Crated(in.) 46X45 X52 46X45X52 48X45X52 48X45X52 WEIGHT Shipping(lbs.)/Net(lbs.) 432/358 451/377 438/374 453/379 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (c) Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. (e) This value is approximate.For more precise value,see Unit Nameplate. (f) Standard Air-Dry Coil-Outdoor. (0) Based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. MODEL 4YCC4042A1060A 4YCC4042A1090A 4YCC4048A1070A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Performance Cooling BTUH(a) 40500 40500 46500 Indoor Airflow(CFM) 1450 1450 1600 Power Input(KW) 3.4 3.4 4.06 EER/SEER(BTU/Watt-Hr.) 12.0/14.00 12.0/14.00 11.50/14.00 Sound Power Rating[dB(A)](b) 74.6 74.6 72.5 PERFORMANCE HEATING(c) Input BTUH-1st Stage (Natural Gas)(d) 60000 90000 70000 AFUE 81 81 81 Temp.Rise-Min/Max(°F) 30/60 35/65 30/60 Orifice Qty/Drill Sz.(Natural Gas) 2/#37 3/#37 2/#33 POWER CONN.-V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Min.Brch.Or.Ampacity(e) 28.5 28.5 32.0 Fuse Size-Max.(amps) 45 45 50 Fuse Size-Recmd.(amps) 45 45 50 COMPRESSOR SCROLL SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 R.L.Amps-L.R.Amps 16.7/109.0 16.7/109.0 19.6/130.0 OUTDOOR COIL-TYPE SPINE-FIN SPINE-FIN SPINE-FIN Rows/F.P.I 2/24 2/24 2/24 Face Area(sq.ft.) 15.63 15.63 20.54 Tube Size(in.) 3/8 3/8 3/8 INDOOR COIL-TYPE MCHE MCHE MCHE Rows/F.P.I 2/16 2/16 2/16 22-1901-1B-EN 7 • TRANE Product Specifications MODEL 4YCC4042A1060A 4YCC4042A1090A 4YCC4048A1070A Face Area(sq.ft.) 3.9 3.9 3.9 Tube Size Width(in.) .81 .81 .81 Refrigeration Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN-TYPE SWEPT SWEPT SWEPT DIA.(IN.) 28.25 28.25 28.25 DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 DIRECT/1 CFM @ 0.0 in.w.g.(f) 3400 3400 4800 Motor-HP/R.P.M 1/4/825 1/4/825 1/4/825 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps 1.51/3.07 1.51/3.07 1.51/3.07 INDOOR FAN-TYPE CONSTANT TORQUE ECM CONSTANT TORQUE ECM CONSTANT TORQUE ECM Dia.x Width(in.) 10.62 X 10.62 10.62 X 10.62 10.62 X 10.62 Drive/No.Speeds DIRECT/3 DIRECT/3 DIRECT/3 CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor-HP/R.P.M. 3/4/1050 3/4/1050 3/4/1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 6 6 6 COMBUSTION FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive/No.Speeds DIRECT/1 DIRECT/1 DIRECT/1 Motor-HP/R.P.M. 1/34/3345 1/34/3075 1/34/3290 Volts/Ph/Hz 230/1/60 230/1/60 230/1/60 FLA .20 .24 .20 FILTER/FURNISHED NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY Recmd.Face Area(sq.ft)(h) 5.3 5.3 5.3 REFRIGERANT R-410 R-410 R-410 Charge(lbs.) 7.3 7.3 7.5 CHARGING SPECIFICATIONS Subcooling 10° 10° 10° GAS PIPE SIZE(in.) 1/2 1/2 1/2 DIMENSIONS HXDXW HXDXW HXDXW Crated(in.) 46 X 47 X 62 46 X 47 X 62 50 X 47 X 62 WEIGHT Shipping(lbs.)/Net(lbs.) 555/452 561/457 552/448 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. (0) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. Co Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 40/per 1000 ft.elevation. (d) Convertible to LPG. (e) This value is approximate.For more precise value,see Unit Nameplate. (f) Standard Air-Dry Coil-Outdoor. (5) Based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Performance Cooling BTUH(a) 46500 58000 58000 Indoor Airflow(CFM) 1600 1760 1760 Power Input(KW) 4.09 4.94 4.94 8 22-1901-1 B-EN • TRANE Product Specifications MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A EER/SEER(BTU/Watt-Hr.) 11.50/14.00 11.50/14.00 11.50/14.00 Sound Power Rating[dB(A)](b) 72.5 73.1 73.1 PERFORMANCE HEATING(c) Input BTUH-lst Stage (Natural Gas)(d) 90000 90000 115000 AFUE 81 81 81 Temp.Rise-Min/Max(°F) 35/65 30/60 30/60 Orifice Qty/Drill Sz.(Natural Gas) 3/#37 3/#37 3/#33 POWER CONN.-V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Min.Brch.Cir.Ampacity(e) 32.0 39.1 39.1 Fuse Size-Max.(amps) 50 60 60 Fuse Size-Recmd.(amps) 50 60 60 COMPRESSOR SCROLL SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 R.L.Amps-L.R.Amps 19.6/130.0 24.4/144.2 24.4/144.2 OUTDOOR COIL-TYPE SPINE-FIN SPINE-FIN SPINE-FIN Rows/F.P.I 2/24 2/24 2/24 Face Area(sq.ft.) 20.54 22.99 22.99 Tube Size(in.) 3/8 3/8 3/8 INDOOR COIL-TYPE MCHE PLATE FIN PLATE FIN Rows/F.P.I 2/16 4/15 4/15 Face Area(sq.ft.) 3.9 5.0 5.0 Tube Size Width(in.) .81 3/8 3/8 Refrigeration Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN-TYPE SWEPT SWEPT SWEPT DIA.(IN.) 28.25 28.25 28.25 DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 DIRECT/1 CFM @ 0.0 in.w.g.(f) 4800 4800 4800 Motor-HP/R.P.M 1/4/825 1/3/825 1/3/825 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps 1.51/3.07 1.7/3.5 1.7/3.5 INDOOR FAN-TYPE CONSTANT TORQUE ECM CONSTANT TORQUE ECM CONSTANT TORQUE ECM Dia.x Width(in.) 10.62 X 10.62 11.87 X 10.68 11.87 X 10.68 Drive/No.Speeds DIRECT/3 DIRECT/3 DIRECT/3 CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor-HP/R.P.M. 3/4/1050 1/1050 1/1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 6 6.9 6.9 COMBUSTION FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive/No.Speeds DIRECT/1 DIRECT/1 DIRECT/1 Motor-HP/R.P.M. 1/34/3075 1/34/3075 1/34/3055 Volts/Ph/Hz 230/1/60 230/1/60 230/1/60 FLA .24 .24 .25 FILTER/FURNISHED NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY Recmd.Face Area(sq.ft)(h) 5.3 5.3 5.3 REFRIGERANT R-410 R-410 R-410 22-1901-1 B-EN 9 • TRANE" Product Specifications MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A Charge(lbs.) 7.5 9.65 9.65 CHARGING SPECIFICATIONS Subcooling 10° 11° 11° GAS PIPE SIZE(in.) 1/2 1/2 1/2 DIMENSIONS HXDXW HXDXW HXDXW Crated(in.) 50 X 47 X 62 50 X 47 X 62 50 X 47 X 62 WEIGHT Shipping(lbs.)/Net(lbs.) 557/453 580/476 586/482 (°) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (') Ratings shown are for elevations up to 2000 R.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. (e) This value is approximate.For more precise value,see Unit Nameplate. (f) Standard Air—Dry Coil—Outdoor. (a) Based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. 10 22-1901-1B-EN 9 TRAM' Indoor Fan Performance . Table 1. Horizontal Airflow 1 4YCC4024A1 EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 T 0.5 0.6 0.7 0.8 0.9 1.0 HEAT- CFM 1123 1059 994 943 889 - - - - - - LOW WATTS 143 152 160 167 ! 175 - - - - - - tilt HEAT- CFM - - 1122 1069 1022 974 922 871 809 - - HIGH WATTS - - 213 221 229 238 245 253 261 - - COOLING CFM 873 811 754 690 614 537 482 441 390 - - -LOW WATTS 84 91 98 105 113 119 123 126 132 - - COOLING CFM 954 900 846 794 729 650 588 535 488 - - -MED WATTS 107 114 121 128 138 147 152 157 161 - - COOLING CFM 1041 993 938 890 836 777 707 644 594 - - -HIGH WATTS 135 142 150 158 167 175 185 191 196 - - Table 2. Down Airflow 4YCC4024A1 EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT- CFM 1123 1059 994 943 889 - - - - - - LOW WATTS 143 152 160 167 175 - - - - - - HEAT- CFM 1240 1184 1122 1069 1022 974 922 871 - - - HIGH WATTS 193 202 213 221 229 238 245 253 - - - COOLING CFM 865 803 746 683 608 532 478 436 386 - - -LOW WATTS 85 92 98 106 114 119 123 127 133 - - COOLING CFM 945 891 838 786 722 643 582 530 483 - - -MED WATTS 108 115 122 129 138 148 153 158 162 - - COOLING CFM 1031 983 929 881 828 769 700 637 588 - - -HIGH WATTS 136 143 151 159 167 176 186 192 197 - - Table 3. Horizontal Airflow 4YCC4030A1 EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT- CFM 1148 1103 1061 1022 982 932 - - - - LOW WATTS 199 208 216 224 233 243 - - - - - HEAT- CFM - - - 1158 1122 1084 1039 988 - - - HIGH WATTS - - - 301 310 320 331 343 - - - COOLING CFM 1051 994 939 889 840 775 708 642 582 - - -LOW WATTS 126 134 142 150 158 167 176 184 188 - - COOLING CFM 1156 1107 1054 1009 965 919 862 799 732 - - -MED WATTS 166 175 184 192 200 209 219 230 239 - - COOLING CFM 1278 1236 1187 1141 1099 1059 1017 968 - - - -HIGH WATTS 221 230 240 250 259 268 278 289 - - - Table 4. Down Airflow 4YCC4030A1 EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT- CFM 1136 1091 1050 1012 972 922 - - - - - LOW WATTS 197 205 214 222 230 241 - - - - - HEAT- CFM - - - 1147 1111 1073 1028 978 - - - HIGH WATTS - - - 298 307 317 328 339 - - 22-1901-1 B-EN 11 • TRANE' Indoor Fan Performance Table 4. Down Airflow(continued) COOLING CFM 1041 984 930 880 831 768 701 635 576 - - -LOW WATTS 126 135 143 150 158 168 177 184 189 - - COOLING CFM 1144 1096 1044 999 956 910 853 791 724 - - -MED WATTS 167 176 185 193 201 210 220 231 240 - - COOLING CFM 1266 1224 1175 1129 1088 1048 1007 959 - - - -HIGH WATTS 222 231 241 251 260 270 279 290 - - - 7t Table 5. Horizontal Airflow 4YCC4036A1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1185 1141 1099 1055 1009 968 920 854 808 731 624 HEAT-LOW WATTS 241 251 260 270 279 289 299 311 320 306 284 CFM 1386 1354 1311 1276 1238 1198 1164 1069 805 689 596 HEAT-HIGH WATTS 386 399 409 419 430 441 452 432 320 303 298 CFM 1131 1092 1058 1022 983 942 899 857 804 - - COOLING-LOW WATTS 247 254 262 269 277 285 291 300 311 - - CFM 1256 1223 1193 1167 1136 1101 1065 1026 955 - - COOLING-MED WATTS 339 350 358 366 374 383 391 399 386 - - CFM 1402 1372 1344 1316 1289 1241 1144 1025 - - - COOLING-HIGH WATTS 471 479 488 497 506 499 454 406 - - - 4YCC4036A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1362 1330 1301 1272 1242 1210 1148 - - - - HEAT-LOW WATTS 429 438 445 455 464 473 458 - - - - CFM - 1366 1338 1310 1280 1234 1153 1038 888 - - HEAT-HIGH WATTS - 474 483 491 501 495 463 413 357 - - CFM 1131 1092 1058 1022 983942 899 857 804 - - COOLING-LOW - WATTS 247 254 262 269 277 285 291 300 311 - - CFM 1256 1223 1193 1167 1136 1101 1065 1026 955 - - COOLING-MED WATTS 339 350 358 366 374 383 391 399 386 - - CFM 1402 1372 1344 1316 1289 1241 1144 1025 - - - COOLING-HIGH WATTS 471 479 488 497 506 499 454 406 - - - Table 6. Down Airflow 4YCC4036A1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1173 1130 1088 1044 999 958 911 846 800 724 618 HEAT-LOW WATTS 238 248 258 267 277 286 296 308 316 303 282 CFM 1373 1340 1298 1263 1225 1186 1153 1058 797 682 590 HEAT-HIGH WATTS 382 395 405 415 425 437 448 428 317 300 295 CFM 1124 1087 1053 1016 978 938 895 852 800 - - COOLING-LOW WATTS 246 255 263 271 278 285 293 301 312 - - CFM 1249 1216 1185 1155 1122 1089 1054 1016 934 - - COOLING-MED - - - - - WATTS 343 351 359 367 376 384 392 400 379 - - CFM 1390 1357 1329 1301 1273 1212 1125 1008 - - - COOLING-HIGH WATTS 476 485 493 501 508 488 449 398 - - - 4YCC4036A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1350 1317 1289 1260 1231 1197 1134 - - - - HEAT-LOW - WATTS 432 441 449 456 465 475 453 - - - - CFM - 1349 1319 1292 1264 1206 1118 1009 850 - - HEAT-HIGH WATTS - 474 486 494 503 487 446 401 337 - - 12 22-1901-1B-EN • TRANE` Indoor Fan Performance Table 6. Down Airflow(continued) CFM 1124 1087 1053 1016 978 938 895 852 800 - - COOLING-LOW - - - WATTS 246 255 263 271 278 285 293 301 312 - - CFM 1249 1216 1185 1155 1122 1089 1054 1016 934 - - COOLING-MED WATTS 343 351 359 367 376 384 392 400 379 - - CFM 1390 1357 1329 1301 1273 1212 1125 1008 - - - COOLING-HIGH - WATTS 476 485 493 501 508 488 449 398 - - - Table 7. Horizontal Airflow 4YCC4042A1060A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1104 1042 977 911841 764 687 598 - - - HEAT-LOW - - WATTS 109 116 124 134 142 152 161 171 - - - CFM - 1171 1112 1050990 927 851 779 704 - - HEAT-HIGH - WATTS - 154 162 172 182 192 203 214 225 - - CFM 1358 1393 1348 1296 1253 1204 1157 1096 1057 988 - COOLING-LOW - WATTS 224 233 242 252 262 272 283 295 305 319 - CFM 1521 1490 1448 1391 1362 1338 1315 1307 1254 1148 - COOLING-MED WATTS 306 316 327 337 348 359 369 382 395 407 - CFM 1659 1637 1604 1594 1529 1491 1467 1425 1385 1345 - COOLING-HIGH WATTS 409 421 432 443 455 467 477 490 503 513 - 4YCC4042A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1419 1380 1341 1295 1249 1204 1160 1115 1069 1015 961 HEAT-LOW WATTS 240 250 259 269 279 291 302 312 323 333 348 CFM 1559 1524 1483 1443 1401 1363 1319 1276 1233 1195 1147 HEAT-HIGH WATTS 313 324 335 346 356 367 379 392 403 415 428 CFM 1358 1393 1348 1296 1253 1204 1157 1096 1057 988 - COOLING-LOW WATTS 224 233 242 252 262 272 283 295 305 319 - CFM 1521 1490 1448 1391 1362 1338 1315 1307 1254 1148 - COOLING-MED WATTS 306 316 327 337 348 359 369 382 395 407 - CFM 1659 1637 1604 1594 1529 1491 1467 1425 1385 1345 - COOLING-HIGH WATTS 409 421 432 443 455 467 477 490 503 513 - Table 8. Down Airflow 4YCC4042A1060A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1109 1047 982 916 845 767 690 601 - - - HEAT-LOW WATTS 109 117 125 134 143 153 162 172 - - - CFM - 1177 1117 1055 995 931 856 783 707 - - HEAT-HIGH WATTS - 155 163 173 182 193 204 215 226 - - CFM 1345 1379 1334 1283 1241 1192 1145 1085 1046 979 - COOLING-LOW WATTS 228 238 247 257 267 278 289 301 312 325 - CFM 1506 1475 1433 1377 1348 1325 1302 1293 1241 1136 - • COOLING-MED WATTS 312 322 333 344 354 366 377 389 403 415 - CFM 1642 1621 1588 1578 1514 1476 1453 1411 1371 1331 - COOLING-HIGH WATTS 417 430 441 452 464 477 487 499 513 523 - 4YCC4042A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1426 1387 1348 1301 1255 1210 1166 1120 1074 1020 966 HEAT-LOW WATTS 241 251 260 270 281 292 303 314 325 335 349 CFM 1567 1531 1491 1450 1408 13701326 1282 1239 1201 1152 HEAT-HIGH - WATTS 315 325 337 347 358 368 381 394 405 417 430 22-1901-1B-EN 13 0 TRANS` Indoor Fan Performance Table 8. Down Airflow(continued) CFM 1345 1379 1334 1283 1241 1192 1145 1085 1046 979 - COOLING-LOW - - - WATTS 228 238 247 257 267 278 289 301 312 325 - CFM 1506 1475 1433 1377 1348 1325 1302 1293 1241 1136 - COOLING-MED - - WATTS 312 322 333 344 354 366 377 389 403 415 - CFM 1642 1621 1588 1578 1514 1476 1453 1411 1371 1331 - COOLING-HIGH - WATTS 417 430 441 452 464 477 487 499 513 523 - Table 9. Horizontal Airflow 4YCC4048A1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1120 1047 980 914 840 758 674 581 - - - HEAT-LOW WATTS 117 126 135 145 156 168 179 188 - - - CFM - 1204 1149 1095 1043989 926 858 798 - - HEAT-HIGH - WATTS - 176 185 195 205 216 227 239 249 - - CFM 1583 1542 1502 1460 1415 1371 1326 1282 1230 1181 - COOLING-LOW - - WATTS 302 313 324 332 345 353 368 376 394 406 - CFM 1763 1723 1689 1648 1609 1568 1527 1488 1447 1404 - COOLING-MED - WATTS 414 426 436 448 459 471 483 495 510 524 - CFM 1945 1910 1876 1839 1806 1769 1728 1688 1652 1545 - COOLING-HIGH WATTS 553 566 577 590 601 613 631 643 647 611 - 4YCC4048A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1419 1380 1341 1295 1249 1204 1160 1115 1069 1015 961 HEAT-LOW - • WATTS 240 250 259 269 279 291 302 312 323 333 348 CFM 1559 1524 1483 1443 1401 1363 1319 1276 1233 11951147 HEAT-HIGH - WATTS 313 324 335 346 356 367 379 392 403 415 428 CFM 1583 1542 1502 1460 1415 1371 1326 1282 1230 1181 - COOLING-LOW WATTS 302 313 324 332 345 353 368 376 394 406 - CFM 1763 1723 1689 1648 1609 1568 1527 1488 1447 1404 - COOLING-MED WATTS 414 426 436 448 459 471 483 495 510 524 - CFM 1945 1910 1876 1839 1806 1769 1728 1688 1652 1545 - COOLING-HIGH - - WATTS 553 566 577 590 601 613 631 643 647 611 - Table 10. Down Airflow 4YCC4048A1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1126 1052 985 918 845 762 677 584 - - - HEAT-LOW - - WATTS 117 127 136 146 156 168 180 189 - - - CFM - 1210 1154 1100 1048 994 930 862 802 - - HEAT-HIGH WATTS - 177 186 196 206 217 228 240 250 - - CFM 1567 1526 1487 1445 1401 1358 1312 1270 1218 1169 - COOLING-LOW - - WATTS 308 320 330 339 352 360 375 384 402 413.9 - CFM 1745 1706 1672 1632 1593 1552 1512 1473 1433 1390 - COOLING-MED - - - WATTS 422 434 444 457 468 480 493 505 520 534 - CFM 1925 1890 1857 1821 1788 1751 1711 1671 1635 1530 - COOLING-HIGH WATTS 564 577 589 602 613 625 644 656 660 623 - 4YCC4048A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1426 1387 1348 1301 1255 12101166 1120 1074 1020 966 HEAT-LOW - WATTS 241 251 260 270 281 292 303 314 325 335 349 CFM 1567 1531 1491 1450 1408 1370 1326 1282 1239 1201 1152 HEAT-HIGH -- WATTS 315 325 337 347 358 368 381 394 405 417 430 14 22-1901-1B-EN • TRANE° Indoor Fan Performance Table 10. Down Airflow(continued) CFM 1567 1526 1487 1445 1401 1358 1312 1270 1218 1169 - COOLING-LOW - WATTS 308 320 330 339 352 360 375 384 402 413.9 - . CFM 1745 1706 1672 1632 1593 1552 1512 1473 1433 1390 - COOLING-MED - -- WATTS 422 434 444 457 468 480 493 505 520 534 - CFM 1925 1890 1857 1821 1788 1751 1711 1671 1635 1530 - COOLING-HIGH - WATTS 564 577 589 602 613 625 644 656 660 623 - Table 11. Horizontal Airflow 4YCC4O60A109OA EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1534 1489 1445 1403 1361 1314 1275 1234 - - - HEAT-LOW - WATTS 281 292 304 314 325 337 348 358 - - - CFM - 1594 1551 1511 1471 1430 1386 1344 1305 1265 - HEAT-HIGH - WATTS - 348 361 373 384 396 409 420 432 443 - CFM 1857 1831 1800 1766 1737 1692 1655 1617 - - - COOLING-LOW - WATTS 515 523 533 544 554 569 582 595 - - - CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 - COOLING-MED WATTS 749 759 769 779 788 803 816 830 845 860 - CFM 2201 2177 2152 2127 2105 2071 2041 2009 1975 1940 - COOLING-HIGH - WATTS 900 910 921 932 941 956 969 983 997 1010 - 4YCC4060A115A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1827 1792 1757 1721 1685 1646 1605 1570 - - - HEAT-LOW WATTS 492 505 517 529 541 553 566 577 - - - CFM - 1927 1894 1861 1824 1788 1750 1711 1674 1639 - HEAT-HIGH WATTS - 614 627 639 651 664 677 689 702 715 - CFM 1857 1831 1800 1766 1737 1692 1655 1617 - - - COOLING-LOW WATTS 515 523 533 544 554 569 582 595 - - - CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 - COOLING-MED WATTS 749 759 769 779 788 803 816 830 845 860 - CFM 2201 2177 2152 2127 2105 2071 2041 2009 1975 1940 - COOLING-HIGH WATTS 900 910 921 932 941 956 969 983 997 1010 - Table 12. Down Airflow 4YCC4O60A1090A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1541 1497 1452 1410 1367 1321 1281 1240 - - - HEAT-LOW WATTS 282 293 305 316 327 339 349 360 - - - CFM - 1602 1558 1518 1478 1437 1392 1351 1311 1271 - HEAT-HIGH WATTS - 350 363 374 386 398 411 423 434 v 445 - CFM 1857 1831 1800 1766 1737 1692 1655 1617 - - - COOLING-LOW - WATTS 515 523 533 544 554 569 582 595 - - - CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 - - COOLING-MED WATTS 749 759 769 779 788 803 816 830 845 860 - CFM 2201 2177 2152 2127 2105 2071 2041 2009 1975 1940 - COOLING-HIGH WATTS 900 910 921 932 941 956 969 983 997 i 1010 - 4YCC4060A115A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1815 17901757 1712 1679 1648 1613 1574 - - - HEAT-LOW - - - WATTS 510 520 532 v 549 v 560 570 582 v 596 - - - CFM - 1910 1875 18391803 1773 1736 1704 1661 1622 - HEAT-HIGH - - WATTS - 630 634 647 660 672 685 698 712 726 - 22-1901-1 B-EN 15 TRANS Indoor Fan Performance Table 12. Down Airflow(continued) CFM 1857 1831 1800 1766 1737 1692 1655 1617 - - - COOLING-LOW WATTS 515 523 533 544 554 569 582 595 - - - _ CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 - COOLING-MED WATTS 749 759 769 779 788 803 816 830 845 860 - CFM 2201 2177 2152 2127 2105 2071 2041 2009 1975 1940 - COOLING-HIGH WATTS 900 910 921 932 941 956 969 983 997 1010 - 16 22-1901-1B-EN 0 TRANE° • Field Wiring Diagram • Figure 1. 4YCC4— Field Wiring Diagram PACKAGEI GAS-ELECTRIC UNIT -- -- -- -- -- -- -- -- UNIT CONTROL BOX TWO STAGE HEAT 'I THERMOSTAT CONNECTIONS I I • I • -11 I I J L B COMMON R G FAN(GR) -_- Y COMPRESSOR I 1 R W11 HEAT FIRST STAGE (WH) R ___ ____W21 HEAT SECOND STAGE(WH) RR 24V UNIT LOW VOLTAGE AREA GROUND, WIRE 1I PH IBIGIYIw1IW2IRI POWER TYPICAL 2 STAGE TEAT THERMOSTAT 3 PH POWER UNIT NOTE 1 -- -- -- -- -- -- -- SINGLE STAGE ECONOMIZER ACCESSORY THERMOSTAT CONNECTIONS CONNECTIONS TO ECONOMIZER FACTORY PROVIDED FIELDR INSTALLED WII I • AM -- II B COMMON I I I L_TSEIeu� B G FAN(GR) L „Etnl R I Y COMPRESSOR ,ZEIeRI W11 HEAT FIRST STAGE (WH) G (GR) • W21HEATSECONDSTAGE(WH) L ,<DIPRI • A. ri R 24V Y I UNIT LOW VOLTAGE AREA _Si_ W1 (WH) urvlT LOW T W2(WH) VOLTAGE AREA S� R 011®11 TYPICAL 1 STAGEFIELD HEAT THERMOSTAT INS/ALLED NOTE 6 JUMPER IYII G IY2Iw1IW2IRC,RHI TYPICAL 2-STAGE THERMOSTAT NOTES: 1. FUSED DISCONNECT SIZE, POWER WIRING AND GROUNDING INTER-COMPONENT WIRING OF EQUIPMENT MUST COMPLY WITH CODES. 2. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT AND 24V. FACTORY HEATER NAMEPLATE. LINE V. WIRING 3. LOW VOLTAGE WIRING TO BE 18 AWG MINIMUM CONDUCTOR. LIN. WIRING 4. SEE UNIT DIAGRAM FOR ELECTRICAL CONNECTION DETAILS. 5. THE THERMOSTAT ON THE GAS/ELECTRIC UNIT MUST PROVIDE WIRE COLOR DESIGNATION A 'G' SIGNAL IN THE COOLING MODE ONLY. DURING THE ABBR COLOR ABBR COLOR HEATING MODE THE FAN WILL BE ENERGIZED BY THE SYSTEM, BK BLACK PR PURPLE 6. FOR SINGLE STAGE THERMOSTATS JUMPER W1 AND W2 TOGETHER. BL BLUE RD RED SECOND STAGE HEAT WILL BEGIN 10 MINUTES AFTER FIRST BR BROWN WH WHITE STAGE. GR GREEN YL YELLOW OR ORANGE C 757192i2 22-1901-1 B-EN 17 0 771M/E® • • Wiring Figure 2. 4YCC4024—4042 - 1 OUTDOOR SECTION INDOOR SECTION - CONTROL BON CN-7 CN-8 OM o CN$ • _ YELLOW 65A(YL) BLACK YELLOW 1, m Wz ^'' 36A(BL) 36C(BL) CN-9 ami 7A(P12) 436N(BL1 Lzi o Jd m CA( CR 67A(YL) BLACK < s 1 m1 9A(BR) ORANGE m ' COMPRESSOR 2 1 A(Y LI—o LOAD o SECTION -_ .- MEM III® ORANGE ,. a m_m m IC(RD)OIN E -. m 35C(RD) VIII 63W GXD 0 40A(GR) .- a a < m V m CPR r ,n cu ,o KONEN M a 17 C 73A(P111)--0 )--0LOAD wo41AIWH1 a S 0 R 51111011 111101 pp ^3 • • ' 0 036EIBL1 — ® O' 4—.a 1 Ro -358, Da CE Bo 366.0(850(0111 •• • i w 2 HEAT —�a_ < m COOL 7. TH o 57A(OR) NLI O m 0 _ ®0 �p o TRV-364(BL) y V ^ co c0 0 H AT RR V m CC _51172.-f fHT 10 M M D U. fDLVCLELLOW s_ V V m FTEI 4 < a N 2A(BK) COM (0; 59A(BK) _C IA(RD) 230V M TCO40 47A(GR) ,_,12i •3A(BL) (owl [M0. TNS1 Q IVi .IA(RD) 37A(OR) _ I 57A(BL) 39A(ORI- 20811 1•24v I LPCO 36A(BL) 38A(GR) 0 fi TEL LOW K 38A(GRI 36B(BL)� YELLOW SIA(6Y) 1-1 I • _ -B 43A(BR) �LOWER CONTROL 800 47A(GR)� /SAIBNI� I I CS CSR I 67AIOL)T G HPCO 19BIOR1 FO 46(80) EIJ _ -Y BLACK ,�_ \I V • • Optional ' 4IA(WH)? BLACK EM mw field -W W 0 0 Installed l 35B(RD1� I`9-1r-���P---P�° a o s m- - S tar) N I I: -R mC _..m o.—..] 498(PR) a; A A NOTES: CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT. NA COLOR A88R COLOR RE COLOR DESIGNATION SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER ARB CONNECTIONS.LOW VOLTAGE WIRING TO UNIT MAY 8E NEC 8L BLACK PR PURPLE CLASS 2 AND MUST BE A MINIMUM OF 18 A.W.G. BL BLUE RD RED SET THERMOSTAT HEAT ANTICIPATOR TO 3 AMPS. BR BROWN WN WHITE 2. MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) GR GREEN IL YELLOW BETWEEN 'B' AND 'R' OF 0.5 AMPS. 24 VAC IS OR ORANGE GY GRAY AVAILABLE IN THE COOLING MODE ONLY. FOR 208 VOLT OPERATION MAKE THE FOLLOWING WIRING DEVICE DESCRIPTION LINE CHANGES CC COMPRESSOR CONTACTOR COIL _ 50 A: AT TNS( REMOVE IAIRDI WIRE AND CONNECT TO 2080 TERMINAL ON TRANSFORMER. CFI OUTDOOR FAN CAPACITOR 17 4. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS CN CONNECTOR OR WIRE OR UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE CEN COMBUSTION FAM MOTOR 2/ WIRING MATERIAL RATED AT 105° C. CPR COMPRESSOR 15 CR COMPRESSOR RUN CAPACITOR 15 CS COMPRESSOR START CAPACITOR II CON COMPRESSOR START RELAY COIL II FD FLAME DETECTOR 44 36E(BL) RO ROLLOUT LIMIT 40 FIF(RD) GV GAS VALVE 35 I-2DI BNI IDA INDOOR FAN MOTOR 24 • 1 IGH IOL IGNITION CONTROL MODULE INTERNAL 27,10 G LOWVOLTAGE COMMONROBEL OAD G : ALT ERNATE GROUND LOCATION IP IGGNITOR PROBE /5 L : LINE VOLTAGE I 0 LED IGN DIAGNOSTICS INDICATOR 40 N : NEUTRAL ODM OUTDOOR FAN MOTOR 20 I : FAN/COOLING LOW I I Ia I I PP POLARIZED PLUG 36-11 2 : FAN/COOLING MED PS PRESSURE SWITCH 40 r 3 : FAN/COOLING HIGH 1 2 1 5 TCO TEMPERATURE LIMIT SWITCH 40 4 : HEAT LOW 61A(RD- 1XSI CONTROL POWER TRANSFORMER 32 5 : HEAT HIGH 63A0L1-- 13A(PR) LPCO LOW PRESSURE SWITCH 50 598160) FU FUSE 42 HPCO HIGH PRESSURE SWITCH 50 IDM CONNECTION FTBA FAN TERMINAL BLOCK 49 ITvq.0758015102 18 22-1901-1 B-EN 0 TRANS Wiring • Figure 3. 4YCC4024—4042 CAUTION-NOT SUITABLE FOR USE ON ®WARN I NG • 1 — SYSTEMS EXCEEDING ISO VOLTS TO HAZARDOUS VOLTAGE! GROUND. DISCONNECT ALL ELECTRIC POWER 2 — ATTENTION: NE CONVIENT PAS POUR INCLUDING REMOTE DISCONNECTS LES INSTALLATIONS DE PLUS DE MODELS BEFORE SERVICING. 3 — 1500. A TERRE. FAILURE TO DISCONNECT POWER SUPPLY 4YCC4024A* BEFORE SERVICING CAN CAUSE SEVERE 1 PERSONAL INJURY OR DEATH. 4 -- UNIT FACTORY WIRED 4YCC4030A* ZLAVERTISSEMENT 5 — FOR 230V 4YCC4036A* VOLTAGE HASARDEU%! _ SEE WIRING DIAGRAM NOTES FOR DECONNECTEZ TOUTES LES SOURCES 6 REOUIRED WIRING CHANGES WHEN 4 Y C C 4 0 4 2 A* ELECTRIOUES INCLUANT LES DISJONCTEURS INSTALLED ON A 208V POWER SUPPLY. SITUES A DISTANCE AVANT D'EFFEC TUER 7 L'ENTRETIEN. FAUTE DE DECONNECTER LA SOURCE ELECTRIOUE AVANT D'EFFECTUER 8 POWER SUPPLY PER LOCAL CODES L'ENTRETIEN PEUT ENTRAINER DES SEE NAMEPLATE FOR LINE VOLTAGE. BLESSURES CORPORELLES SE VERES 9 — 1 —..—..—. —-- OU LA MO R T. 10— 1 8B(OR) • CSR csR cs L CAUT ION _ ___ 6A(0_R 3D(RD) I I I— I [_ 4B(BK)„(3„ - _ I USE COPPER CONDUCTORS ONLY! I .-j �`L'� UNIT TERMINALS ARE NOT DESIGNED 12-- I � R2 I I TO ACCEPT OTHER TYPES OF CONDUCTORS. — I FAILURE TO DO SO MAY CAUSE DAMAGE 13— �V I LOPTIONAL START KIT TO THE EQUIPMENT. I BLACK I 1 4— .CC-2 l I BLACK °C IS— 28.C,D(BK) • 01� r 3D(RD), 1HERM ORANGE0 CPR 16— 4C(BK) I 38(RD) �CR IOL 17— IA,C,F(RD) ` �10 313(RD).RED ly COM-7(..4 RED R II RED 1 ' 18— I «a1 19— 9A(BR) `•,`"' BROWN 3 20— 7A(PR) I ti PURPLE 2a 21-- 4C(BK) 4C(BK) CF ' BLACK 22— 23— 2D(BK1 2D(BK) N 24— • IF(RD) 1F(RD) '® L R 25— 26— 27— W KN tl lc(RD) - HE „__ 2 A(Y L) 2 A(Y L) • YELLOW 2 9— • 2C I BK l INDUCER • 8 2C(BK) BLACK CI 30— : 2A(BK) COM 31— >0 3 IA(RD) 230V 8, 38A(GR) 32— Q t7 33 -- ISN JUMPER SETTINGS TSI "�"„�36AIBL) 36CIBL) • 34— COOL 1010 NEAT 6161 HEAT - 24 V. CN-6 FAM OFF DELAY FAN OFF DELAY FAN ON DELAY 15 SEC• in 0 90 SEC• ®e AS SEC FIXED O MN 35— a SEC ® 60 SEC o® ^ Da 1W° 36KIBL1 D11 FACTORY SETTING NEA/ 376— 'i' COOL cm PP_l>�43AIBRI I MAIN 3 7— ON[MAl1rI05TIC NDICATUt ®O H STATUS LID FLASH acesUTIPORT PLASH COM RED 2 J 38— OFF=CHECK POKERLOMAT.OR BAD BOARD 2: I AN.LOUT.NO FLAME IN C N. SLOB=NORMAL.NO CALL FOR NEAT INDUCER pp.1 51A(GYI 39— •3:PRESS SNI IC NI INDUCER ISSu[ O TCO�� FAST:C ALI FOR NEAT 1.OPEN LIMIT IiC00A A01 IN pp.y» 31A(OR) _ � `_��[ c_Pj_NO'SUB)YL) 40— SOLID ON: !VERNAL ERROR- 5.FLAN[NIO w6 VALVE BLo CR PPB / 39AIOA1 `rrL r �” REPLACE CONTROL �� 39B(OR) 4.) — 1.GAS VALVE CIRCUIT ERROR B'.LON FLAKE SENSE 35CIRD1 TH pp.6>> 49AIPR1 19BIPR) 42_ 35BIRD)R - pp.3>}55AIYLI 43— a- R pp./» 45A113K1 FD 44— bR /1 AI WHIW ORORANGE 0 I 0 Li 45— Ro- p Bo 360.DIBU 41A(GRIG • 46.— 66- I OG E GAD 0 /717 /0 Al 47— OR O 13AIPR) INDUCER LOAD FTBA 48— olio 73A(PR) Yo-___, , •AI:K) IOTA 36E(BLI • 49— L 4 BOER LOAD :i 61AIRD) I OL C 50— Bo--- 67A(Y IY BLACK FPCU CN-8 LPCO - I 6 MI ) ••36C.D.EIBLI 5I— THERMOSTAT I �i CN-9 CN-7 L Fr 360/BE IB BLACK YELLOW CC YELLOW— PRINTED FROM D7580 I 5P02 22-1901-1B-EN 19 0 TRANE Wiring Figure 4. 4YCC4048 —4060 OUTDOOR SECTION INDOOR SECTION — CONTROL BOX Ch1-7 CN-8 COM Chhe 110 CA — YELLOW ft65A(YL) BLACK ftYELLOW L.... 30(RO)�ORANGE 36A(BL) 36C(BL) CN-9 va 0 �// 36K(BL I /I/�--�I? x 2 a.m CFI 670(YL I� `-BLACK a Mt J 3C(RD) COMPRESSOR 7A(PR) 9A(BR) J m p SECt10N g 21A(YL)— LOAD INDUCER IG O ORANGE r CC mJ m cm IC(RD) DIN m V GO0 IOA(GRI - a as a 35C(RD) oIN 03NI mo m CPRBLOM - M C r he tO 73A(PR)—OLOAD WO—/IAIWHI Las (BLa PM S O R kill Pnu pp M o o 36EI O� D t Ro-35B,C(RD) _____0o— 80 36B.DIBL1 •• • i ¢ NEAT L�i._'.�p -moo o-- a m COOL TN 0 57A(OR) o O m N _ m0 iR -36AIBL) .. 1, m m Y a H AT R ''''''''':"1: _ 'H L) — ¢ N .. _ ___ M M 0 tL CRA 00 JDLUCL4YE1LON_Q 26(86) COMPS 9FTBA a .0 - C (] 590(86) —C IA(RD) 230V I I [NO. mist Q 47A(GR) C .3A(BL) 37AIOR1 I_ • • 57A(OR) Iii •IA(RD) 208V: 1 24V I I 39A(OA) L.PCO • 36A(BL) 38A(GR) 0 fi YELLOW— ) 380(08) 366(8L)� YELLOW l�/) SI A(6Y1 �� I LOWER CONTROL.BOx 47A(GR)- -B 43A(8R1 ' /SA(BNI CS CSR I 67A(YL)-3., -G FICO GV 398(SRI FD 48(86) S _Y li BLACN0 , �O \I I/ 41A(WH)7 1"I LL••ii�a Optional BLACK R0 < w Field 35B(RD) -W o IP y o Ly Installed Gino) Nil: -R 498(PR) , M0 p a NOTES: K CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT. WIRE COLOR DESIGNATION ABBR COLOR ABBR COLOR SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER BN BLACK PR PURPLE CONNECTIONS.LOW VOLTAGE WIRING TO UNIT NAY BE NEC CLASS 2 AND MUST BE A MINIMUM OF 18 A.W.G. BL BLUE RD RED SET THERMOSTAT HEAT ANTICIPATOR TO .3 AMPS. BR BROWN WH WHITE 2. MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) GR GREEN YL YELLOW BETWEEN 'B' AND "R" OF 0.5 AMPS. 24 VAC IS OR ORANGE Gr GRAY AVAILABLE IN THE COOLING MODE ONLY. FOR 208 VOLT OPERATION MAKE THE FOLLOWING WIRING DEVICE DESCRIPTION LINE CHANGES, A: AT MIN( REMOVE ISFORl WIRE AND CONNECT TO 208V CC COMPRESSOR CONTACTOR COIL 50 TERMINAL ON TRANSFORMER. CFI OUTDOOR FAN CAPACITOR I7 4. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS CN CONNECTOR OR WIRE NUT CFN COMBUSTION FAN MOTOR 27 UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE WIRING MATERIAL RATED AT 105° C. CPR COMPRESSOR 15 CR COMPRESSOR RUN CAPACITOR 15 CS COMPRESSOR START CAPACITOR II CSR COMPRESSOR START RELAY COIL II FD FLAME DETECTOR 11 36E(8L) RO ROLLOUT LIMIT 40 FIF(RD) GA GAS VALVE 35 r2D(BN) IN INDOOR FAN MOTOR 24 1 LGN IGNITION CONTROL MODULE 27,40 C = LOW VOLTAGE CONMONIOL INTERNAL OVERLOAD G = ALTERNATE GROUND LOCATION IP IGNITOR PROBE45 L - LINE VOLTAGE I I I LED IGN DIAGNOSTICS INDICATOR 40 N = NEUTRAL — a ODM OUTDOOR FAN MOTOR 20 I = FAN/COOLING LOW I I 1 To PP POLARIZED PLUG 3641 2 : FAN/COOLING MEO PS PRESSURE SWITCH 40 3 = FAN/COOLING HIGH 2 4 5 • TCO TEMPERATURE LIMIT SWITCH 40 4 = HEAT LOW 61AIRDlJ I TNS( CONTROL POWER TRANSFORMER 32 5 = HEAT HIGH 63A(BL H— 73A(PR) LPCO LOW PRESSURE SWITCH 50 59A(BK) Fu FUSE 42 HPCO HIGH PRESSURE SWITCH 50 IDM CONNECTION FTBA FAN TERMINAL BLOCK 49 DWG.0758016002 PO 22-1901-1 B-EN • TRANE ' Wiring • Figure 5. 4YCC4048—4060 CAUTION-NOT SUITABLE FOR USE ON ZEW A R N I NG • I — SYSTEMS EXCEEDING 150 VOLTS TO HAZARDOUS VOLTAGE! GROUND. DISCONNECT ALL ELECTRIC POWER 2 ATTENTION: NE ONS ITPAS OUR MODELS INCLUDING REMOTE DISCONNECTS LESDEPLUS DE BEFORE SERVICING. 3 — 150V. A TERRE. , FAILURE TO DISCONNECT POWER SUPPLY BEFORE SERVICING CAN CAUSE SEVERE 4YCC4048A* PERSONAL INJURY OR DEATH. 4 -- UNIT FACTORY WIRED 4YCC4060A* AAVERTISSEMENT 5 FOR 230V VOLTAGE HASARDEUX! _ SEE WIRING DIAGRAM NOTES FOR DECONNECTEZ 70UTES LES SOURCES 6 REQUIRED WIRING CHANGES WHEN ELECTRIOUES LANCE AVANT7 LES DISJONCTEURS INSTALLED ON A 208V POWER SUPPLY. LI TUTS A DISTANCE DECOND'EFFNECTER TuER 7 L'E N7RE7IEN. FAUTE DE DECONNEC7ER LA SOURCE ELECTRIOUE AVANT D'EFFECTUER 8 — POWER SUPPLY PER LOCAL CODES L'ENTRETIEN PEUT ENTRAINER DES SEE NAMEPLATE FOR LINE VOLTAGE. __ _ OUE CAU MORTCORPORELLES SEVERES 9 r.._..—..—.. 8B(OR) 0— I ,— i .4B(BK)CSR r CSR 6A10_R CS 3DcRQ) �° C A U T ION II— I-- USE COPPER CONDUCTORS ONLY! I 1 I r - '-' 2 R2 I UNIT TERMINALS ARE NOT DESIGNED 12— I i°I y TO ACCEPT OTHER TYPES OF CONDUCTORS. -- - I :DPTI�AL FAILURE TO DO SO MAY CAUSE DAMAGE 13— II / / I L y TO THE EOU I PMENT. I4— I BLACK 15— 2A,C,D(BK) S•CC-2s1� r 3D(RD) BLACK °C 16— 4C(BKl I 3B(RD)01 _ ORANGES CPR OL 17— IA,C.F(RD) R • 1° 3B(RD),RED lr RED RED 18— Fad 19— 2 9A(BR) ,�w BROWN 3 CFI 20— 3CIRDI 3CIRD) 'E 7A(PR) I /,rte.1 PURPLE 2 M) I IOL 21— 4C(BK) 4C(BK) I <<_ BLACK 22— • 2D(BK) .R(BK) N 24— Q•® 24— 5 — IF(RD) IF(R•) L 25-- 26-- 27-- V III �_ I C(R D) D L^— 2 I A(Y L) 2 A(Y L) YELLOW CO F 28— �R,,E1 ,IH ROAD Aj' INDUCER 0 29— • 2C(BK) _ 2C(BK) BLACK 30— 2A(BK) COM <3 1 3I— o. IA(RD) 230V. �° 38A(GR) 32—33 — LGN JUMPER SETTINGS 1 1 °'r'v�36A1BLI • 36CIBLI 34 — COOL I.5INI HEAT OM NEAT -- 21 V. CN-6 FAN Off DELAY FAN OFF DELAY FAN ON DELAY IS SEC• ® 90 SEC• ® IS SEC FIXED m IR O 06NIBL1 35— 0 SEC a 60 SEC WI •FACTORY SETTERS NEAT 36— '^ toot13AIB 1C IIDIRI I MAIN ION OIAON051CATOR DMPP'=» V 37— H Krum Lilo mummows WOW FLAY[=MB RED 2 38— OFF-CHECK POWER OR BAD BOARD 2:I NN.10CAUUT.NO FLARE IN 0 39— SLOWSNOAYAL. NO CALL FOR NEAT 3 PRESS SYIICN/I NDUC[R DEAD INODUCFA PP,>> SIAIGTI 7C0 �00 PB N0. PAST=C AIL FOR NEAT A 01[N IEMI F 11(0 ON ROI IN 31AIOR1 I SSAI TLI J 40— _ _ BLOWER PP H)) I r SOLID OR: INTERNAL ERROR- 5:FLAME R/0 GAS VALVE 0 39AIOR1 4 I — REPLACE CONTROL 1-GAS VALVE CIRCUIT ERROR PP B�� 39BIQA1 8:LOW FLAY[SENSE 35CIRD1 TN PP-6>}-19AIPR1 �198(PRI 42— \6'PV SSA(YL) Q- 35BI RDIR R PP-3�� <SA(BX) FD 43— I p PP-I>> _ 44— dR I I /IAIWNIM ON ORANGE F °LJ o • •-, 4 5— Wo- t7 368.01811 /7AIGRIG OS BO • 46— Go- 1AOMORI F GAD 0 47 • 47— oY o 73A(PR) INDUCER LOAD 48— OLIO TSAIPRI �SSRAIRX) 360(BL I • 49— BLONER LOAD 17AIGRIG -SAI: I Y' A• •C Yo- ;I y 50— 67611 IT BLACK FPCC3 CN-8 LPCO . AIT I ••36C.D.EIBL1 51— B°----1 CN-9 CN-7 L ICi'36BIBLIN BLACK TELCO CC THERMOSTAT YELLOW Dwc 0750000y1 22-1901-1 B—EN 21 9 MANE' Full Perimeter Roof Mounting Curb Figure 6. 4024—4036 Models BAYCURB050A Full Perimeter Roof Mounting Curb 17 7/8 46 3/8 3 4. RETURN ,o, 3 5/8 AIR .., I SUPPLY AIR od• i. 19 1/2 41 414 2 3/16 411r19 1/2/ i / 15 ..,. N%slib://0. A 11, 38 7/8 o - 1 1/2 The drawings on this page are prepared by the manufacturer in order to provide detail regarding / job layout only. These drawings are not intended to / be used as a basis to construct, build or modify the / items depicted in the drawings. The manufacturer / is not responsible for the unauthorized use of these A , * B >• drawings and expressly disclaims any liability for / damages resulting from such unauthorized use. 'ETUR`. DC CHANNEL SIDE CHANNEL END 011p ,..- . WOOD NAILER SERVICE CLEARANCE DIMENSIONS HOLE IN ROOF ,2' A B C D wC*/TC* 42. 00 36. 00 12. 00** 24. 00 433/8 DC*/YC* 42. 00 36.00 12. 00** 36.00 35 7/8 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 22 22-1901-1B-EN • TRANE ' Full Perimeter Roof Mounting Curb • Figure 7. 4042 — 4060 Models BAYCURB051A Full Perimeter Roof Mounting Curb 15 7/8 56 1/8 3 RETURN AIR ' I 11/2 ; SUcPPRLY /, .off -,- 19 107/8 191/2 20ill► e 4 3/4 19 1/2 .- 41 41 7/8 u N.z1 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the i items depicted in the drawings. The manufacturer i N is not responsible for the unauthorized use of these N drawings and expressly disclaims any liability for damages resulting from such unauthorized use. i <A \ ---- --- < N N. N �U RR\ /• --- N N ` / AIR ---- N N, SUPPLY j AIR ir. CHANNEL SIDE . CHANNEL END N 011WOOD NAILER SERVICE CLEARANCE DIMENSIONS HOLE IN ROOF A B C D --- WC*/TC* 42.00 36.00 12.00** 24.00 / DC*/YC* 42.00 36.00 12.00** 36.00 38 7/8 53 1/8 \ ** 42.00 WISH ECONOMIZER WITH 25% FRESH \�// AIR ACCESSORY 22-1901-1 B-EN 23 0 TRNVE' Optional Equipment — Economizer Table 13. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC UnitEconomizer Unit Application \ Models Economizer i 0000 00000.x• rain hood ®® o® ` BAYECON 101A 4024-036 '1 ' % , ,, _ Outside air �A, 1 dampers \� r%'/ Return air�. ``` 6 ;46dampers J Required filter kit,order Mist Ott separately eliminator ... • 4 ) BAYECON102A 4042-060 Relief —Return damper Duct Roofcurb/ �_ Table 14. BAYCON200,201A Horizontal Economizer and Rain Hood < > > • \moi Economizer \ I I,\ I . I N Gaskets (2) Duct 41111' f— Rain Hood r" .:-. ... 1% Mixed Air / Sensor ' Economizer Models A B C D E F BAYECON200AA 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201AA 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 24 22-1901-1B-EN 0 TRINE' • Optional Equipment — Outside Air Damper • Table 15. BAYOSAH001 and 002A Manual Fresh Uca t Application A B C D Air Model Models 0:1111111 — )1 a ` FULLY OPEN BAYOSAHOO1A 4024-4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" FULLY B CLOSED BAYOSAHOO2A 4042—4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 16. BAYDMPR101 and 102A,25%Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) Manual Fresh Unit Air Model Application A B C D A Models Pr' Iti itil . — BAYDMPR101A 4024—4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" i e / BAYDMPR102A 4042—4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" ♦— D —* l Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 22-1901-1 B-EN 25 TRANS Optional Equipment — Filter Rack Figure 8. BAYFLTR101 Filter Rack(4024-4036) BAYFLTR102(4042-4060) (Mounts in Filter/Coil Section) IIS �h Lam • •li • •it ,,,,,,..,H �f Figure 9. BAYACCDOR1A Hinged Filter Access Door(4024-4036) BAYACCDOR2A(4042-4060) Replaces Filter/Coil Access Panel .,, ----I_.._L - 11 •: ',,ii-', 41 I \ I I i-I' I I .tea . Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 26 22-1901-1B-EN • 1 1 1 TRANE® • Outline Drawings Figure 10. 4YCC4024-4036 1210 28 — D — u8-27/32] C 1 11./6 l INLET [IS/321 91.96 (DUCT FLANGE) 13.27/321 W2 .- / W3 'cI( 109/.99 11fIW/'��! 1 III 1111 f/3-u8) INLET t 1111,,`,�'//�l)�l lll� I �� INLET 18 03 IB 29 � �e- -....--- 201 FLUE [23/32] 123/321 �� FLUE '7-1-.- 14.22 201.63 [9/16] \_+ 1115/161 WI / - W/ SECTION Y-Y A TYPICAL 181 SIDES OF DOWNFLOW DUCT OPENINGS INLET TOP SIDE ENTER OF GRAVITY Ali OUTLET .r L _ T V ,lIT III I A , 251D FRONT SIDE [1] ONDENS DRAIN FOR 1123 --��jj 19.0 13/1/411 FEMALE NPT 118-8-23/32] LEFT SIDE 1 . 10 , H______ % Note: The view labeled "Bottom side" 0 represents the base as viewed looking41111_AL________, up from underneath the unit. Y Y 1. 1 / i BOTTOM SIDE 22-1901-1 B-EN 27 • TRANE Outline Drawings s i 1 lia iiii E....... ,,,,_.. Figure 11. 4YCC4024-4036 ' I I ID s1i_ ,� �� �� 296.62 [11-11/16] (OUTSIDE) o �, 1-!I� �� 58. 19 \ .' ./// RETURN [2-9/32] \� ....--- 171.55 SUPPLY sr^ [7] ...---- 398.22 [15-11/16] 79.50 ---4"' (OUTSIDE) [3-1/8] 116.01 398.22 - ' [6 IS/16] [15-II/16] (OUTSIDE) b�� •-11-.; BACK DUCT OPENINGS - .I J • • lIX14,1 ' .. • 17.T8 530.60 [11/16] �. � [20.1/8] • X X X . I i I SECTION /� TYPICAL (81 SIDES OF 51DE110W DUCT OPENINGS 4 �•4 1155.46 [45-1/2] (SURFACE AREA) BACK SIDE Height mm/in Flu Hood w/brkt Approx.Corner Weight-kg/lbs Shipping Total Unit Center of Gravity mm/in mm/in Weight Weight A D W1 W2 W3 W4 kg/lbs kg/lbs B C • 4YCC4024(060) 898.53[35-3/8] 157.16[6-3/16) 58.3[129] 36.8[81] 26.1[58] 41.0[90] 196.1[432] 162.4[358] 479.8[18.9] 527.8[20.8] 4YCC4030(070) 898.53[35-3/8] 157.16[6-3/16] 61.3[135] 38.7[85] 27.5[61] 43.1[95] 204.8[451] 171.1[377] 406.5[16.0] 594.1[23.4] 4YCC4036(070) 949.33[37-3/8] 157.16[6-3/16] 61.1[134] 38.3[84] 27.1[60] 43.2[95] 203.4[438] 169.7[374] 414.3[16.3] 697.6[27.5] • 4YCC4036(090) 949.53[37-3/8] 157.16[6-3/16] 61.7[136] 38.9[86] 27.7[61] 43.7[96] 205.7[453] 172.0[379] 414.3[16.3] 697.6[27.5] 28 22-1901-1B-EN TRANS' Outline Drawings i • Figure 12. 4YCC4O24-4036 1181.17 157.31 158.9/16) 16-3/161 • C 1 11.56 INLET [15/32] (DUCT FLANGE) 11.18 .- [II/16] 4 W2 W3 SECTION v vV TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS '.... •=.%."' 1125 22 ■lblliii���FFF . i\IIllll`u'■ 114-5/161 INLET 111',,, 1,''I'� ■ ( INLET 1 / AAA 18 03 18.29 \\\`' .,% // /LUE [23/321 123/32] \��`\�\ HOOD . 1 1 B "� i�� 14.22 \ � r 19/161 201.6/161 1 [1-165 SECTION Y-Y WI $ WI TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS INLET TOP SIDE ENTER OF GRAVITY 4 OUTLET IL.—.. -.. -- A ,..„. ...—— , a ' \ A 25.40 551.43 FRONT SIDE [I) [21-23/32] ONDENSATE DRAIN FOR 19.0 13/41 FEMALE NPT LEFT SIDE RECOMMENDED SERVICE CLEARANCE MM/IN. Iht WITH O.A. DAMPER/ECON. OBACK SIDE 301.8 [121 762.0 1301OLEFT SIDE 911.1 [361 1066.8 [42] ,RIGHT SIDE 911.4 136] FRONT SIDE 1066.8 1421 - CLEARANCE TO COMBUSTIBLE MATERIAL MM/IN. Y Y 1 / I BOTTOM 0 T BACK SIDE 25.4 [I] '.. LEFT SIDE 152.4 [6] -- - RIGHT SIDE 304.8 [121 FRONT SIDE 304.8 (12) TOP 914.4 [361 BOTTOM SIDE 22-1901-1 B-EN 29 TRIUNE Outline Drawings Figure 13. 4YCC4042-4060 x 1487 17 - 151.31 (58-9/161 16-3/161 I C ---1 11.56 1 INLET 115/321 (DUCT FLANGE) 1.18 111/161 6 $ x2, M3 V ` SECTION )0( =� TYPICAL (8)SIDES OF SIDEFLON DUCT OPENINGS j_ jj� \. `I III '•U,'�' \ \C 1125 22 11111 i/i/il((Ii:TTI . ,1.1�1',,iiil� Ill-SII 1 INLET 1i,(( , I INLET 111pa�.;;.,: 1!it�i «111 {,,,.i�t� 18 03 18 29 \\\\...TEI422 sFLUE 33(321 123(32] HOOD .16 400010016. ' � ,e- 14 f 19/l61 101.61 1115/161 SECTION Y'Y NI ���NI t TYPICAL 181 SIDES OF DOWNIE°,DUCT OPENINGS INLET TOP SIDE ENTER OF GRAVITY 4 OUTLET IL ,_H ,I, 1 , _ , 11 I A [1110 12/23/321 ONDENSATE DRAIN FOR PONT SIDE 19.0 13/11 FEMALE APT LEFT SIDE AECOMM(xDfO SERVICE CLEARANCE M14/111. ILI Al WITH 0.A. DAMPER/ECON. O BACK SIDE 301.8 1121 162.0(301 O LEFT SIDE 911.1 1361 1066.8(421 RIGHT SIDE 911.1 1361 —- - -- ----A FRONT SIDE 1066 8 1421 - • CLEARANCE TO COMBUSTIBLE MATERIAL MN/IN. Y Y BOTTOM 0 BACK SIDE 25 4 III LEFT SIDE 152.1 161 RIGHT SIDE 301.8 1121 Note: The view labeled FRONT SIDE 3o1.a 1121 "Bottom Side"represents • the base as viewed looking TOP 914 4 1361 up from underneath the unit. BOTTOM SIDE • 30 22-1901-1 B-EN a 9 TRANE Outline Drawings Figure 14. 4YCC4042-4060 ---121111111 /, �� 372.82 ID .- [(TOUTS I/DE)] 58. 19 �� l-L1E �1TURN [12-23 SUPPLY �- (12 23/32] 449.02 [17-11/16] 79.50 J' (OUTSIDE) [3-1/8] 449.02 176.07 [6-15/16] [17-11/16) (OUTSIDE) BACK DUCT OPENINGS .-.--. -- • • • . 530.60 • •# ..� " [20-7/8] � X x • . . . ej 1402.34 I [55-7/32) (SURFACE AREA) BACK SIDE • Height mm/in Approx.Corner Weight-kg/lbs Shipping Total Unit Center of Gravity mm/in Model Weight Weight A W1 W2 W3 W4 kg/lbs kg/lbs B C 4YCC4042(060) 898.53[35-3/8] 71.2[157] 46.6[103] 34.6[76] 53.1[117] 252.2[555] 202.0[452] 470.0[18.5] 731.0[28.8] 4YCC4042(090) 898.53[35-3/8] 71.8[158] 47.2[104] 35.2[78] 53.6[118] 254.5[561] 207.3[457] 470.0[18.5] 731.0[28.8] 4YCC4048(070) 1000.13[39-3/8] 71.4[157] 44.6[98] 33.2[73] 53.9[119] 250.3[552] 202.1[448] 433.0[17.0] 743.3[29.3] 4YCC4048(090) 1000.13[39-3/8] 72.0[159] 45.0[99] 33.8[75] 54.4[120] 252.6[557] 205.4[453] 433.0[17.0] 743.3[29.3] 4YCC4060(090) 1000.13[39-3/8] 77.1[170] 45.8[101] 34.4[76] 58.3[128] 263.1[580] 215.9[476] 433.0[17.0] 743.3[29.3] 4YCC4060(115) 1000.13[39-3/8] 78.0[172] 46.3[102] 34.9[77] 59.0[130] 265.8[586] 218.6[482] 414.0[16.3] 635.0[25.0] 22-1901-1 B-E N 31 TRANS' Outline Drawings Figure 15. 4YCC4042-4060 • ___.__/-Hr:.dtittit; ...- „„ i i i . iiii ��� iii i�i� --I ,---- iii iiaii6i ��:�$$��i,� i�iiii-iii ii �'�'�.�''���\� iiii •iiii •iiii �\I���,�'���!� i. iii ii iiii ����i����i� iliiiiiii i� `�'��'�;� i�i iii 0 • �� iii \ / • 0 o 31 .00 / 5]1[ • ( IN] -' I� ( INSIDE) • ..... �`! / 318.75 457.20 \mss ' 1 \ �'�u � RETURN [ 12-9/161 [ I8] ,� 457.20 ( INSIDE) SUPPLY [ 18] 75.41 / ( INSIDE) [2-31/32] 75.41 244.09 [2-31/32] 381 .00 [9-5/8] ( 15] ( INSIDE) BOTTOM DUCT OPENINGS y 0 • I I. I . 24V ENTRY _ 0 0 r- 1 t .• Il A c 359.80 294.02 •`FA [ 14-5/32] [ II -9/161 178.66 . [1 1/321 • e .t 4 POWER ENTRY 84 96 GAS LINE ENTRY 27.78 DIA. HOLE [3-11/321 I FOR 12.70 [ I/2] N.P.T. [ 1 -3/321 GAS CONNECTION 98.66 �[3 7/8] 127.84 RIGHT SIDE (5-1/321 32 22-1901-1 B-EN TRANE Notes 22-1901-1 B-EN 33 TRANS Notes 34 22-1901-1B-EN 9MANE Notes 22-1901-1 B-EN 35 19R CERTIFIED.. C www.ah rid i recto ry.trg C US Unitary Small AC AftI Standard 210/240 come,em axu=s.iy woo-vomri•rr.rm- Intertek `11eCa A T ., Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand,the leader in creating and sustaining safe,comfortable and energy efficient environments,Trane offers a broad portfolio of advanced controls and HVAC systems,comprehensive building services,and parts. For more information,visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. L:2014 Trane 22-1901-1B-EN 01 Dec 2014 ($ Ingersoll Rand Supersedes 22-1901-1A-EN (November 2014)