Loading...
Plans (3)FPS2015-00008 ON C L0 00 O N 0 W z o: a J SITE LINCOLN 5 10200 SW GREENBURG RIF TIGARD, OR 97223 INSTALLER CAPITOL ELECTRIC . 11401 NE MARX ST PORTLAND, OR 98220 oaici, oiiiaicCi. iycv. SALES REPRESENTA TI VE BRYAN ADAMS 503-683-9000 4 m9l 6305 SW ROSEWOOD ST, SUITE A LAKE OSWEGO, OR 97035 PHONE: 503-683-9000 n � SERVICE: 503-683-9001 FAX: 503-675-6521 TM DRA WINGS PREPARED BY MARIA GERRONE NICET LEVEL 111 #126987 DRAWING INDEX SHEET# DESCRIPTION FA -001 COVER SHEET FA -002 GENERAL INFORMATION FA -101 DEVICE PLACEMENT PLAN FA -601 CALCULATIONS AND SCHEDULES FA -701 WIRING TYPICALS t JAN 2 0 2015 CITY Of fIGARD BUILDING DIVISION uVi \w Grff OF'T'IGA" REVD FOR CO OMPLUNCE U Approved: O OTC: ( ] W Permit #: ^` zcf-s-- r — Address: 2ui Suite #: �G B} : Daltez OFFICE COPY i O � CL Lom Z N z W� OE O "� C) i�o c Z 0NQ E N L .3 L N VJ C O Z O U W Y S U O U W 0 O J W �L Cn ¢ N DRAWN BY: M. GERRONE CHECKED BY M. GERRONE ISSUE DATE: 1/23/15 JOB #: PROJECT #: 448:982542601 SIMPLEXGRINNELL © 2015 SYSTEM: FIRE ALARM SYSTEM SHEET: COVER SHEET FA -001 Q CL w J Ill z O o: w m 0 w Q cn J Q O Lo 15: co to O N co 0 Lu z o= 1 GENERAL NOTES 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE®DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES. WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE` AND SHALL BE USED FOR INSTALLATION. 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK -ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 6. UPDATE THE AS -BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS -BUILT DRAWING SET TO SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON -POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC. 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON -POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED -NECESSARY, HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. SYSTEM DESCRIPTION / SCOPE OF WORD OCCUPANCY TYPE: B BUSINESS GROUP SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES FOR SUITE 740 IN LINCOLN BUILDING 5. CONNECT NEW RELAY IAM FOR EGRESS CONTROL TO EXISTING 4100ES FACP AND NEW NOTIFICATION DEVICES TO EXISTING NAC PANEL 7B. ALL NEW WIRING TO BE CLASS B. THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FIRE ALARM APPLICABLE CODES STANDARDS OREGON FIRE CODE, 2014 EDITION OREGON MECHANICAL SPECIALTY CODE, 2014 EDITION OREGON ELECTRICAL SPECIALTY CODE, 2011 EDITION NATIONAL FIRE ALARM CODE (NFPA 72), 2013 EDITION JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. c ADDRESSABLE CARD (IDNET OR MAPNET) I ( DEVICE ADDRESS M2-1 ADDRESSABLE DEVICES NUMBERING CIRCUIT DESIGNATOR 4009 'NAC PANEL V=VISUAL OR A/V, H=AUDIBLE ONLY) (WHEN APPLICABLE) I- DEVICE DESIGNATOR NAC 1:V2-1 VISUAL AUDIBLE OR A,& DEVICE SYMBOL KEY FIRE ALARM SYMBOLS LEGEND WIRE SCHEDULE DESCRIPTION ABBREVIATIONS LEGEND NAC EXTENDER PANEL AC = ABOVE CEILING HT = HEIGHT NAC7B # DESIGNATES THE NAC PANEL NUMBER C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING MANUAL PULL STATION SIMPLEX 4099-9001 E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM SIMPLEX 4098-9714 RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM 4" OCTAGONAL BOX 1 1/2" DEEP DUCT SENSORJDETECTOR_ RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM L� RL = RELOCATED DEVICE N/A = NOT APPLICABLE INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER SUPPLIED BY OTHERS FIRE ALARM WIRE LIST VS TAMPER SWITCH NDU = NETWORK DISPLAY UNIT INSTALLED BY MECHANICAL CONTRACTOR ' WP = WEATHERPROOF NEC =NATIONAL ELECTRICAL CODE CIRCUIT DESCRIPTION RISER RATED: FPLR SINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION M MAPNET/IDNET CIRCUIT SG ANIX./PAIGE 740215 SG ANIX./PAIGE 740214L H = HIGH HUMIDITY NIC = NOT IN CONTRACT 1 PAIR 18 AWG TWISTED AREA=0.0196 SQ. INCH AREA=0.0196 SQ. INCH AFF = ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE U)c T740215 FAMC- 1 802C- 1 -2S-03B5 ALM = ALARM PAP = PRE -ACTION PANEL SMOKE DETECTOR END -OF -LINE RESISTOR 6.8K (EOL) ANN =ANNUNCIATOR SCC =STATUS COMMAND CENTER V VISUAL SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE BMS =BUILDING MANAGEMENT SYSTEM SLC =SIGNALING LINE CIRCUIT 2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH CBC =CALIFORNIA BUILDING CODE SMK =SMOKE SOLID ANIXTER PART NUMBER (2 14 AWG � ANIXTER PART NUMBER CD = (eg. 15CD) CANDELA SUPV =SUPERVISORY FA -1402C -1 -1N -03 -BX AREA# 0.0097 SQ. INCH (EACH FA -1402C -1-2N-03 CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA DET = DETECTOR TRBL = TROUBLE 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * DGP = DATA GATHERING PANEL TS = TAMPER SWITCH 3/4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * EOL = END OF LINE TYP = TYPICAL 1 " 0.34 SQ INCH * 2" 1.34 SQ INCH * EPO = EMERGENCY POWER OFF LION = UNLESS OTHERWISE NOTED * 40% FILL PER N.E.C. FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL F = FIRE ALARM TERMINAL CABINET VT =VALVE TAMPER FBO =FURNISHED BY OTHERS WF =WATER FLOW CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE FCC = FIRE COMMAND CENTER W = (eg. 1/2W) WATT SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS FAA = FIRE ALARM ANNUNCIATOR W/ = WITH CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL .TO THE CIRCUIT FTR FSDSD = =FIRE FIRE ALARM TRANSPONDER SMOKE .DAMPER W/0 =WITH OUT DESIGN OF THIS SYSTEM INSTALLATION. REFERENCE https:,L/www.onixter.com/customer/tycofs FOR SG ANIXTER .CABLE DATA M__ / BATTERY DEICE ADDRESSING LEGEND ADDRESSABLE CARD (IDNET OR MAPNET) I ( DEVICE ADDRESS M2-1 ADDRESSABLE DEVICES NUMBERING CIRCUIT DESIGNATOR 4009 'NAC PANEL V=VISUAL OR A/V, H=AUDIBLE ONLY) (WHEN APPLICABLE) I- DEVICE DESIGNATOR NAC 1:V2-1 VISUAL AUDIBLE OR A,& DEVICE SYMBOL KEY FIRE ALARM SYMBOLS LEGEND SYMBOL DESCRIPTION MODEL# BACKBOX NAC EXTENDER PANEL NAC7B # DESIGNATES THE NAC PANEL NUMBER SIMPLEX A009-9201 SUPPLIED BY SIMPLEXGRINNELL F❑ MANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP SMOKE SENSOR / BASE SIMPLEX 4098-9714 ® SIMPLEX 4098-9792 EASE 4" OCTAGONAL BOX 1 1/2" DEEP DUCT SENSORJDETECTOR_ HEAT SENSOR / BASE SIMPLEX 4098-9733 L� SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP AIM INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG BOX 2 1/2" DEEP WITH COVER WF WATERFLOW SWITCH SUPPLIED BY OTHERS INSTALLED BY MECHANICAL CONTRACTOR VS TAMPER SWITCH SUPPLIED BY OTHERS INSTALLED BY MECHANICAL CONTRACTOR A�O RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8" DEEP W/TWO GANG COVER MAIN FLR. ELEV. LOBBY SMOKE DETECTOR WALL MOUNT MULTI -CANDELA V/0 WHITE SIMPLEX 4906-9103 4" SQUARE BOX 1 1/2" DEEP 0 # =CANDELA RATING W/4905-9940 ADAPTER SKIRT WHEN SURFACE MOUNTED WALL MOUNT MULTI -CANDELA A/V WHITE SIMPLEX 4906-9129 4" SQUARE BOX 1 1/2" DEEP z # =CANDELA RATING W/4905-9940 ADAPTER SKIRT WHEN SURFACE MOUNTED rn `� of o END -OF -LINE RESISTOR 3.3K (EOL)- SIMPLEX 4081-9002 U)c 'V�r END -OF -LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 SUPPLIED BY SIMPLEXGRINNELL SMOKE DETECTOR END -OF -LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 END -OF -LINE RESISTOR 1 OK (EOL) SIMPLEX 4081-9008 NOTE: EXISTING DEVICES SHOWN SHADED FOR REFERENCE. GENERAL NOTES: 1. DEVICES SHOWN ARE TYPICAL. SEE FLOOR PLAN FOR QUANTITY AND LOCATION. 2. ALL WIRING SHALL COMPLY WITH NFPA 70, ARTICLE 760, POWER gMITED SYSTEMS. 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. KEYED NOTES Ol TIE INTO NEAREST EXISTING IDNET DEVICE. v V1 c� (NAC78:V1) SECURITY 10K DOOR V2 (NAC7B:V2) ( PWR BY NAC7B �C ' Lr�C ' 1 O OTHERS 4009 (NAC( ° C 10K 7B:V3) ELEC ROOM v V4 ��_� (NAC7B:V4) I 10K 120 VOLT AC SUITE 570 J 7TH FLOOR SEQUENCE OF OPERATION CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL CD J��p\GP �v�P�v�P���p\G O��'P �\OaD��P� �5 Q O�All CD P�'�JPP'�PP�JPP'�PP'�JPP'.,JPrJPP'�PP'�P SYSTEM INPUTS I A R I CI D I F I F I G I H I I I J I K I I M N 0 1 P 1 D 1 R I S I T I U I V I W I X I Y 1 7 1 AA I AB I AC AD AF AF AG AH SUPPLEMENTARY REMARKS o / • 1 1- oo����000�oo��ao���������e���000�o ©MAN UAL PU LL STATION IN: DUCT SENSORJDETECTOR_ L� W ATRIUM BEAM DETECTOR MAIN FLR. ELEV. LOBBY SMOKE DETECTOR Orf O 0 Lr) m M z Lu O rn `� of o C) U)c O N Q H-ELE"-MECKROOM SMOKE DETECTOR 0 a E 3 L to m 1 0 M TAMPER SWITCH isff -FRE ALARM _AC POWER FAILURE M__ / BATTERY GROUNDFAULT imWIRE-TO-WIRE SHORT I A 1 H I C I D I L I F I G I H I I I J I K I L I M I N 1 U 1 If I Q I K 1 5 1 1 1 U 1 V I W I X I Y I L IAAIAbIAGIAID IALIAF IAGIAMI c I O (V OC:)j c0 {+7 tf) � CO Un u') bi Z! 0� a� a Lu cnco c� Orn o 0 3�co co � oWoM tr U) N o�X o cco :5 cWn Z O C..) W O Y 2 U V w Q �o 0 W Y DRAWN BY: M. GERRONE CHECKED BY M. GERRONE ISSUE DATE: 1/23/15 JOB #: PROJECT #: 448:982542601 SIMPLEXGRINNELL © 2015 SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION FA -002 W L� W W Orf O 0 Lr) m M z Lu O rn `� of o C) U)c O N Q 0 a E 3 L to 0 Z O C..) W O Y 2 U V w Q �o 0 W Y DRAWN BY: M. GERRONE CHECKED BY M. GERRONE ISSUE DATE: 1/23/15 JOB #: PROJECT #: 448:982542601 SIMPLEXGRINNELL © 2015 SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION FA -002 t w z O w C� m O Lu U) U) p 0 N co O w z o= a F- R N _N W Q N AREA OF WORK PLAN NORTH DEVICE PLACEMENT PLAN - 7TH FLOOR SCALE: 1/8" = 1'-0" 0 4 8 16 (IN FEET) TO NAC7B:V4 — 7TH FLOOR SUITE 740 TO NAC7B:V3 — 7TH FLOOR NORTH TO NAC7B:V2 — 7TH FLOOR CORE NAC7B:V1 - NAC7A SILENT KNIGHT TRIGGER t IF OPTIONAL SHIELDS ARE USED FOR ZDNet WIRING. FOLLOW THESE PRECAUTIONS. 1. IF ZDNet WIRING CONTINUES ON TO ANOTHER DEVICE, TAPE SHIELDS TOGETHER. DO NOT TERMINATE SHIELD AT 4009 ZDNet. 2. IF ZDNet WIRING TERMINATES AT THE 4009, TAPE SHIELD. DO NOT TERMINATE SHIELD AT 4009 IDNet oLI X09 e + - + - + - + - NAC t NAC 2 MAC 3 NAC 4 IDNET M ❑ 1 0 t- AUX POWER O� Pm M (�o RUPIN 0 0 FEr w t o o �O 0 REEI'm FOS wr Dim 2 RET IN arr AUDIBLE BATTERY Do ik—p (" 4009-9201 ZDNet NAC EXTENDER 00 as� —St Qo � ps-m o INTERNAL BATTERY HARNESS 733-945 BATTERY BATTERY KEYED NOTES: O1 CONTROL RELAY FOR SECURITY DOOR INTERFACE. VERIFY LOCATION ON SITE. a FROM PREVIOUS ZDNet DEVICES OR HOST ZDNet CONTROL PANEL TO ADDITIONAL ZDNet DEVICES OR RETURN TO HOST ZDNet CONTROL PANEL ZDNet CONTROLLER ADDRESS: CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY —/ GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO THE 4009 SAFETY GROUND STUD. EXISTING NAC PANEL DETAIL SCALE: NTS TERMINAL STRIP PART OF 733-991 COD ia) 1 cn A LoZ7 co C9 0 �� kv W z QaC3c Ow U Lo~ U)o� L owo o0c) pow � 00 V oO wM rr ^^ v o W ,o vJ F - U �0 O V o Y Er C!5 cuj z O 0- a o: c.� W O Y 2 U O U W O cn g DRAWN BY: M. GERRONE CHECKED BY M. GERRONE ISSUE DATE: 1/23/15 CONNECT TO 120VAC 60HZ INPUT 3A MAX. JOB #: PROJECT #: 448:982542601 SIMPLEXGRINNELL © 2015 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN FA -101 O •C U o m E m E .Q U 10 � O CID O w E U w� U m ~ c z E F O z w F of m a E O W ' U) r W W J elf o CD 0— Of u Z CV Z Lu LLJ ti 0-) o IE "� o U 1�o z O N Q 0 E 3 0 0 z O 0- a o: c.� W O Y 2 U O U W O cn g DRAWN BY: M. GERRONE CHECKED BY M. GERRONE ISSUE DATE: 1/23/15 CONNECT TO 120VAC 60HZ INPUT 3A MAX. JOB #: PROJECT #: 448:982542601 SIMPLEXGRINNELL © 2015 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN FA -101 O •C U o m E m E .Q U 10 � O CID O w E U w� U m ~ c z E F O z w F of m a E LINCOLN 5 41 00e FACP Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 4100-9111 1 4100 CONFIG. DOMESTIC 120V * 0.3730 0.3730 0.4700 0.4700 4100-3202 1 4 RELAYS, 10 AMP CONTACTS 0.0150 0.0150 0.1750 0.17510 4100-5005 3 ZONE MODULE, S IDC, CLASS B 0.0750 0.2250 0.1950 0.5850 4100-5101 1 1EXPANSION PWR SUPPLY (XPS) - 120VAC 60HZ 0.0500 0.0500 0.0500 0.0500 4100-6052 1 EVENT REPORTING DACT 0.0300 0.0300 0.0400 0.040p 4100-96xx 1 REMOTE ANNUNCIATORS & MINIPLEX TRANSPONDERS RUI CURRENT DRAWS INCLUDED BELOW Panel Totals 0.6930 1 1.3200 ZDNet Addressable Devices SLC 4099-9001 14 IDNET SINGLE ACTION PULL STATION ** 0.0000 0.0000 0.0000 0.0000 4090-9001 21 IDNET SUPERVISED IAM ** 0.0000 0.0000 0.0000 0.0000 4090-9002 5 IDNET RELAY IAM ** 0.0000 0.0000 0.0000 0.0000 4098-9714 46 TRUEALARM PHOTO SMOKE SENSOR 0.0000 0.0000 0.0000 0.0000 4098-9733 7 TRUEALARM HEAT SENSOR 0.0000 0.0000 0.0000 0.0000 4009-9201 7 4009 IDNET NAC EXTENDER, 120 VAC ** 0.0000 0.0000 0.0000 0.0000 4098-9792 53 TRUEALARM SENSOR BASE ** 0.0000 0.0000 0.0000 0.0000 Miscellaneous Peripheral Devices That May Require System Power 4603-9101 1 1 ISERIAL LCD ANNUNCIATOR 0.0450 0.0450 0.2000 0.2000 Notification Appliances 4906-9101 6 V/0 MC NON -ADDRESS, RED, WALL 15 0.0000 0.0000 0.0600 0.3600 4906-9101 3 V/0 MC NON -ADDRESS, RED, WALL 30 0.0000 0.0000 0.0940 0.2820 4906-9127 3 A/V MC NON -ADDRESS, RED, WALL 15 0.0000 0.0000 0.0750 0.2250 4906-9127 2 A/V MC NON -ADDRESS, RED, WALL 75 0.0000 0.0000 0.2210 0.4420 4906-9128 2 A/V MC NON -ADDRESS, RED CEILING 15 0.0000 0.0000 0.0860 0.1720 G136-24 1 24VDC 6 INCH BELL, RED 1 0.0000 0.0000 0.1000 0.1000 Peripheral Totals 0.0450 x 1.7810 RUI Totals 2 0.0070 M1-10 0.0070 Address Totals 100 Addresses 0.0793 1FL WEST ENTRANCE 0.0979 ** Current draw included under "Device Addresses Used" (See "Additional Current Draws:") Total Standbyl 0.8243 Total Alarml 3.2059 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. a 2. Backup Amplifier assumes Main Amplifier alarm current on failure. Battery Set #1 (Cabinet/Charger 1 Current Total Current Total Select ALL Power Supplies on this battery set: 0.175A 0.03% SWITCH SPS -1 Address 0.6880 1.4700 XPS-2 Location Description 0.0500 1.6310 3 Sub Total 0.7380 3.1010 Additional Current Draws: 8 Current M1-1 RUI Connected Peripheral Devices 2 x 0.0035 = 0.0070 x 0.0035 = 0.0070 MAPNET/ZDNet Device Addresses ordered / used 100 x 0.000793 = 0.0793 x 0.000979 = 0.0979 x Sub Total 0.8243 3.2059 Spare addressable point capacity 0% 0 x 0.000793 = 0.0000 x 0.000979 = 0.0000 L5 Total 0.8243 3.2059 Standby Time = 24 Hrs x 0.8243 = 19.7832 Standby Ah x Alarm Time = 5 Min 0.08333 x 3.2059 = 0.2672 Alarm Ah M1-3 PHOTO SMOKE 20.0504 1 FL SOUTH OF RESTROOMS Additional Spare Capacity = 0% + 0.0000 x x x 20.0504 x Battery Discharge Factor = 20% r + 4.0101 SMOKE Minimum Battery Required 2081-9287 25AH (2x) 24.0604 X Battery Supplied 2081-9276 33AH 2x X X R IDNET CHANNEL M1 Load % Drop NAC7B:V1 NAC7A SILENT KNIGHT TRIGGER SIG1 0.175A 0.03% SWITCH SETTINGS Address Device Type Point Type 5.93% Location Description 1 2 3 4 5 6 7 8 Current M1-1 PHOTO SMOKE L5 1FL TUNNEL LINCOLN 5 ENTRANCE x x x x x x x x ON M1-2 PHOTO SMOKE L5 1FL SOUTH BY TUNNEL x x x x x x x x ON M1-3 PHOTO SMOKE L5 1 FL SOUTH OF RESTROOMS x x x x x x x x ON M1-4 PHOTO SMOKE L5 1FL OUTSIDE OF RESTROOMS X X x X X X X X ON M1-5 NAC4PT SIGNAL L5 1FL ELEC RM NAC1 x x x x x x x x ON M1-6 ADRPUL PULL L5 1FL EAST ENTRANCE x x x x x x x x ON M1-7 PHOTO SMOKE L5 1FL EAST ENTRANCE x x x x x x x x ON MI -8 PHOTO SMOKE L5 1FL MAIL ROOM x x x x x x x x ON M1_9 PHOTO' .SMOKE L5 1FL ELEV LOBBY x x x x x x x x ON M1-10 PHOTO SMOKE L5 1FL WEST ENTRANCE x x x x x x x x ON M1-11 ADRPUL PULL L5 1FL WEST ENTRANCE x x x x xx M1-136 x x ON M1-12 PHOTO SMOKE L5 1FL BY STAIR 2 x x x x x x x x ON MI -13 PHOTO SMOKE L5 1 FL ELEC RM x x x x x x x x ON Ml -14 IAM SO L5 1FL STAIR 2 TAMPER x x x x x x x x ON Ml -15 IAM WATER L5 1FL STAIR 2 WATERFLOW x x x x x x x x ON M1-16 IAM SO L5 1FL STAIR 2 TAMPER x x x x x x x x ON M1-17 IAM WATER L5 1FL STAIR 2 WATERFLOW x x x x x x x x ON M1-18 PHOTO SMOKE L5 1FL TUNNEL x x x x x x x x ON M1-19 x ON M1-143 x x x x x x x x ON Ml -20 x x ON M1-144 x x x x x x x x ON M1-21 x I X1 x ON x x x x x x x x ON Ml -22 x x x Ix x x x x x x x x ON Ml -23 x x x x x x x x x x x x ON M1-24 x x x x x x x x x x x x ON Ml -25 x x x x x x x x x x x x ON Ml -26 x x x x X x X x x x X x ON Ml -27 x x x x x x x x x x x ON M1-28 x x X X x x x x x x ON M1-29 x x x x x x x x x ON M1-30 PHOTO SMOKE L5 2FL SOUTH CORRIDOR X x x x x x x x ON M1-31 ADRPUL PULL L5 2FL STAIR 1 x x x x x x x x ON M1-32 PHOTO SMOKE L5 2FL OUTSIDE OF RESTROOMS x x x x x x x x ON M1-33 PHOTO SMOKE L5 2FL ELEV LOBBY x x x x x x x x ON M1-34 PHOTO SMOKE L5 2FL EAST CORE x x x x x x x x ON M1-35 PHOTO SMOKE L5 2FL NORTH CORE x x x x x x x x ON Ml -36 PHOTO SMOKE L5 2FL WEST CORE x x x x x x x x ON M1-37 PHOTO SMOKE L5 2FL ELEC RM x x x x x x x x ON M1-38 NAC4PT SIGNAL L5 2FL ELEC RM NAC2 x x x x x x x x ON M1-39 PHOTO SMOKE L5 2FL NORTH CORRIDOR x x x x x x ON M1-40 ADRPUL PULL L5 2FL STAIR 2 x x x x x ±XX x ON M1-41 IAM SO L5 2FL STAIR 2 TAMPER x x x x x x x x ON M1-42 IAM WATER L5 2FL STAIR 2 WATERFLOW X x X x X x X X ON Ml -43 x x x x x x x x x x ON Ml -44 X x x x x x x x x ON Ml -45 x X x x x x x X ON Ml -46 X x x x x x X X ON Ml -47 M1-169 x x x x x x x x ON M1-48 ON M1-170 ADRPUL x x x x x x X X ON Ml -49 X ON M1-171 x x x x x x x x ON Ml -50 X X ON M1-172 x x x x x x x x ON M1-51 x X x ON x x X X x x X X ON Ml -52 X x X x x x x x x x X X ON Ml -53 x X x X x X x X x x X X ON M1-54 x x X x X x x X x x X X ON M 1-55 x x x x x x xx ON x x X X oN M1-56 x x x x x x x x x x X X ON M1-57 7FL NORTH CORR BY STAIR 2 x x X x x x x x x X X ON M1-58 L5 7FL STAIR 2 x x X x X x X x X X ON M1-59 SO L5 7FL STAIR 2 TAMPER X x xx X x x x X X ON M1-60 PHOTO SMOKE L5 3FL SOUTH CORRIDOR X X x x x x X X ON M1-61 ADRPUL PULL L5 3FL STAIR 1 x X x x x x x x ON M1-62 PHOTO SMOKE L5 3FL OUTSIDE OF RESTROOMS x x x x x x X X ON M1-63 PHOTO SMOKE L5 3FL ELEV LOBBY x x x x x x X X ON M1-64 PHOTO SMOKE L5 3FL SOUTH OF ELEC RM x x x x x x x X ON M1-65 PHOTO SMOKE L5 3FL ELEC RM x x x x x x x x ON Ml -66 NAC4PT SIGNAL L5 3FL ELEC RM NAC3 x x x x x x x X ON Ml -67 ADRPUL PULL L5 3FL STAIR 2 x x x x x x x x ON M1-68 PHOTO SMOKE L5 3FL NORTH CORRIDOR x x x x x x x x ON M1-69 IAM SO L5 3FL STAIR 2 TAMPER x x x x x x x x ON Ml -70 IAM WATER L5 3FL STAIR 2 WATERFLOW x x x x x x x x ON M1-71 x x x x x x x x x x x x ON Ml -72 x x x x x x x x x x x ON Ml -73 x x x x x x x x x x ON Ml -74 x X x X x X X x X ON Ml -75 HEAT HEAT L5 PH ELEV MACH RM x x X x X X x X ON Ml -76 HEAT HEAT L5 X x X x X X x X ON Ml -77 M1-197 PHOTO SMOKE xX PH ELEV MACH RM x x X X x X ON Ml -78 ON M1-198 PHOTO X x x x x X x X ON Ml -79 x ON M1-199 x x x x x x x x ON MI -80 x x ON M1-200 x x x X x X x X ON M1-81 x x x ON x x X x x X x X ON Ml -82 x x x x x x x x x x x x ON Ml -83 x X X x x x x X x X x X ON M1 -84 X x X x x x x x x x X ON Ml -85 x x x X x x x X x X x X ON Ml -86 x X x x x x x x x X x X ON Ml -87 PH AC -1 DUCT MONITOR X x x x x x X x X x X ON Ml -88 L5 PH AC -2 DUCT MONITOR x x x x x x x x x x ON Ml -89 LSDUCT L5 PH AC -3 DUCT MONITOR x x x x x x X x X ON M1-90 PHOTO SMOKE L5 4FL SOUTH CORRIDOR X x X x x X x X ON M1-91 ADRPUL PULL L5 4FL STAIR 1 x x X x x X x X ON M1-92 PHOTO SMOKE L5 4FL BY RESTROOMS X x x x x X x X ON M1-93 PHOTO SMOKE L5 4FL WEST OF ELEV LOBBY x X x x x X x X ON M1-94 PHOTO SMOKE L5 4FL ELEV LOBBY X x x x x X x X ON M1-95 PHOTO SMOKE L5 4FL NORTH CORRIDOR x x x x x X x X ON M1-96 PHOTO SMOKE L5 4FL ELEC RM x x x x x x x x ON Ml -97 NAC4PT SIGNAL L5 4FL ELEC RM NAC4 x x x x x x x x ON M1-98 PHOTO SMOKE L5 4FL BY STAIR 2 x x x x x x x x ON M1-99 ADRPUL PULL L5 4FL STAIR 2 x x x x x x x x ON M1-100 IAM SO L5 4FL STAIR 2 TAMPER x x x x x x X X oN M1_101 IAM WATER L5 4FL STAIR 2 WATERFLOW x x x x x x x x ON M1-102 x x x x X x x X X x x X ON M1-103 x X x x x x x X X x x X ON M1-104 X x x x x x x X x x X oN M1-105 x x x X X x X x x X ON M1-106 x X x X x X x x X ON M1-107 x x X x X x x X ON M1-108 X X x x X x x X ON M1-109 Ml -227 x X x x X x x X ON M1-110 ON Ml -228 X x x x X X x X ON M1-111 x ON M1-229 x x x x X x x X ON M1-112 x x ON M1-230 x x x x x x x I X ON M1-113 x x x ON x x x x x x x x ON M1-114 x x x x X x X X x x x X ON M1-115 x x x x x x X X x x x X ON M1-116 x x x x X X x X x x x X ON Ml -117 x X x X x X x X x x x X ON M1-118 x x X x X x x X x x x X ON M1-119 x x x x x x X x x x x ON M1-120 ADRPUL PULL L5 5FL STAIR 1 x x x x x x x x ON M1-121 PHOTO SMOKE L5 5FL ELEV LOBBY x x x x x x x x ON M1-122 PHOTO SMOKE L5 5FL ELEC RM X x X x x x x X ON Ml -123 NAC4PT SIGNAL L5 5FL ELEC RM NAC5 x x X x x x x X ON M1-124 ADRPUL PULL L5 5FL STAIR 2 X X x x x x x X ON M1-125 IAM SO L5 5FL STAIR 2 TAMPER x X x x x x x X ON NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. IDNET CHANNEL M1 ELECT RM Load % Drop NAC7B:V1 NAC7A SILENT KNIGHT TRIGGER SIG1 0.175A 0.03% SWITCH SETTINGS Address Module Qty 0.980A 5.93% Description 1 2 3 4 5 6 7 8 Current M1-126 Device IAM WATER L5 5FL STAIR 2 WATERFLOW x x x x x x x x ON M1-127 0.1850 75cd 29 0.22100 0.716 x x x x x x x x ON M1-128 30cd 55 0.09400 1.019 17.98 x x x x x x x x ON M1-129 0.0000 0.2520 0.2520 4906-9101 9 x x x x x x x x ON M1 -11 30 6 V/0 MG NON -ADDRESS, RED, x x x x x x x x ON M1-131 WALL 110 0.0000 0.0000 0.2850 x x x x x x x x ON M1-132 0.0750 0.2250 4906-9127 2 A/V x x x x x x x x ON M1-13.3 A/V MC NON -ADDRESS, RED, WALL 75 x x x x x x x x ON M1-134 1 0.0750 0.0750 0.1750 0.1750 x x x x x x x x ON M1-13:5 2.7150 x x x x x x x x ON M1-136 x x x x x x x x ON M1-137 x x x x x x x x ON M1-138 x x x x x x x x ON M1-139 x x x x x x x x ON M1-140 ADRPUL PULL L5 6FL STAIR 1 x x x x x x x x ON M1-14'1 PHOTO SMOKE L5 6FL ELEV LOBBY x x x x x x x x ON M1-142 PHOTO SMOKE L5 6FL ELECT RM x x x x x x x x ON M1-143 NAC4PT SIGNAL L5 6FL ELECT RM NAC6 x x x x x x x x ON M1-144 ADRPUL PULL L5 6FL STAIR 2 x x x x x x I X1 x ON Ml -145 IAM SO L5 6FL STAIR 2 TAMPER x x x x x x x Ix ON Ml -146 IAM WATER L5 6FL STAIR 2 WATERFLOW x x x x x x x x ON M1-147 x x x x x x x x ON M1-148 x x x x x x x x ON M1-149 x x x x x x x x ON M1-150 x x x X x x x x ON M1-151 x x x x x X X x ON M1-152 x x x x x X X x ON M1-153 x x x x x X X x ON M1-154 X x X x x X X x ON M1-155 x x X x x X X x ON M1-156 x x x x x X X x ON M1-157 x x x x x X X x ON M1-158 x x x x x X X x ON M1-159 x x x x x X X x ON M1-160 x x x x x x x x ON M1-161 x x x x x x x x ON M1-162 x x x x x x x x ON M1-163 x x x x x x x x ON M1-164 x x x x x x x x ON M1-165 x x x x x x x x ON M1-166 X x x X X x X x ON M1-167 x x x x x x x x ON M1-168 x x x x X x X x ON M1-169 x X X x X x X X ON M1-170 ADRPUL PULL L5 7FL SOUTH STAIR 1 X x X x X x X X ON M1-171 PHOTO SMOKE L5 7FL SOUTH CORRIDOR x x X x X x X X ON M1-172 PHOTO SMOKE L5 7FL WEST OF ELEV LOBBY X X x x X x X x ON M1-173 PHOTO SMOKE L5 7FL ELEV LOBBY x X x x X x X x ON M1-174 PHOTO SMOKE L5 7FL TOP OF ELEV SHAFT X x x x X x X x ON M1-175 PHOTO SMOKE L5 7FL NORTH CORRIDOR x x x x X x X x ON M1-176 PHOTO SMOKE L5 7FL ELEC RM x x x x x x x x ON M1-177 NAC4PT SIGNAL L5 7FL ELEC RM NAC713 x x x x x x x x ON M1-178 PHOTO SMOKE L5 7FL NORTH CORR BY STAIR 2 x x X X x x X x ON M1-179 ADRPUL PULL L5 7FL STAIR 2 x x X X x x X x ON M1-180 IAM SO L5 7FL STAIR 2 TAMPER X X x X 0 x X x ON Ml -181 IAM WATER L5 7FL STAIR 2 WATERFLOW x X x X x x X x ON M1-182 HEAT HEAT L5 7FL TOP OF SHAFT X x x X x x X x ON M1-183 HEAT HEAT L5 7FL TOP OF SHAFT x x x X x x x x ON M1-184 HEAT HEAT L5 7FL TOP OF SHAFT x x x x x x x x ON M1-185 RIAM RELAY L5 7FL STE 740 RECEPT EGRESS CONTROL x x x x x x X x ON M1-186 x x X x x x X x ON M1-187 x x X x x x X x ON M1-188 X X x x x x x x ON M1-189 xx x x x x X X ON M1-190 x x x x x x x x ON M1-191 x x x x x x x x ON M1-192 x x x x x x x x ON M1-193 x x x x x x x x ON M1-194 x x x x x x x x ON M1-195 HEAT HEAT L5 PH ELEV MACH RM x x x x x x x x ON M1-196 HEAT HEAT L5 PH ELEV MACH RM x x x x x x x x ON M1-197 PHOTO SMOKE L5 PH ELEV MACH RM x x x x x x x x ON M1-198 PHOTO SMOKE L5 PH ELEV MACH RM x x x x x x x x ON M1-199 HEAT HEAT L5 PH ELEV MACH RM x x x x x x x x ON M1-200 HEAT HEAT L5 PH ELEV MACH RM x x Ix x x x x x ON M1-201 RIAM PRIMARY L5 PH ELEV MACH RM PRIMARY RECALL x x x x x x x x ON M1-202 RIAM ALTERN L5 PH ELEV MACH ,RM ALTERNATE RECALL X x X x X X x x ON M1-203 RIAM RELAY L5 PH ELEV MACH RM HAT FLASH x x X x X X x ON M1-204 RIAM RELAY L5 PH ELEV MACH RM SHUNT TRIP X x x x X X x IXON ON M1-205 IAM SUPERV L5 PH ELEV MACH RM POWER MONITOR x X x x X X x ON M1-206 IAM LSDUCT L5 PH AC -1 DUCT MONITOR X x x x X X x M1-207 IAM LSDUCT L5 PH AC -2 DUCT MONITOR x x x x X X x x ON Ml -208 IAM LSDUCT L5 PH AC -3 DUCT MONITOR x x x x x x x x ON M1-209 IAM SO L5 AHU CONTROL ROOM TAMPER x x x x x x x x ON M1-210 PHOTO SMOKE L5 AHU CONTROL ROOM X x X X x X x x ON M1-211 x x x X x X x X ON M1-212 x x x X x X x X ON M1-213 x X x X x X x x ON M1-214 X x x X x X x x ON M1-215 x x x X x x x x ON M1-216 x x x x x x x x ON M1-217 x X x x x X x x ON M1 -218X x X x x X x x ON M1-219 x x X x x X x x ON Ml -220 x x x x x x x x ON Ml -221 x X x x x X x x ON Ml -222 X x x x x X x x ON M1-223 x x x x x x x x ON Ml -224 x x x x x x x x ON M1-225 x x x x x x x x ON Ml -226 x x x x x x x x ON Ml -227 x xx x x x x x ON Ml -228 x x x x x x x x ON M1-229 x x x x x x x x ON M1-230 X x x X X x x x ON Ml -231 x x x X x x x x ON Ml -232 x x x x x x x x ON Ml -233 x x x x x x x x ON Ml -234 X x X x X x x x ON Ml -235 x x X x X x x x ON Ml -236 x x x x x x x x ON M1-237 x X I x x X x x x ON M1-238 X x x x X x X x ON Ml -239 x x x x X x x x ON M1 -240x x x x x x x x ON Ml -241 x x x x x x x x ON Ml -242 x x x x x x x x ON M1-243 x x x x x x x x ON Ml -244 X X x X x x x x ON M1-245 x X x X x x x x ON Ml -246 x x x X x x x x ON Ml -247 x x x X x x x X ON M1-248 x x x x x x x x ON Ml -249 x x x x x x x x ON THRU ON Ml -250 x x x I x I x x x x ON NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. LINCOLN 5 - NAC 7B 7TH FLR ELECT RM Load % Drop NAC7B:V1 NAC7A SILENT KNIGHT TRIGGER SIG1 0.175A 0.03% NAC7B:V2 NOTIFICATION 7TH FLOOR CORE SIG2 1.020A Module Qty 0.980A 5.93% Description 0.540A Standby Current Total Standby Alarm Current Total Alarm Panel Equipment PID Candela (feet) Current Drop Device NAC7B:V1-1 5495 5 0.17500 0.005 4009-9201 7 1 4009 IDNET NAC EXTENDER, 120 VAC 0.06000 0.0850 0.0850 0.1850 0.1850 75cd 29 0.22100 0.716 18.28 NAC7B:V2-5 Panel Totals 75cd 0.0850 0.22100 0.1850 Notification Appliances NAC7B:V2-6 4906-9101 30cd 55 0.09400 1.019 17.98 NAC7B:V2-7 4906-9101 4906-9101 1 1 V/0 MC NON -ADDRESS, RED, WALL 110 0.0000 0.0000 0.2520 0.2520 4906-9101 9 V/0 MC NON -ADDRESS, RED, WALL 15 0.0000 0.0000 0.0600 0.5400 4906-9101 6 V/0 MG NON -ADDRESS, RED, WALL 30 0.0000 0.0000 0.0940 0.5640 4906-9127 1 A/V MC NON -ADDRESS, RED, WALL 110 0.0000 0.0000 0.2850 0.2850 4906-9127 3 A/V MC NON -ADDRESS, RED, WALL 15 0.0000 0.0000 0.0750 0.2250 4906-9127 2 A/V MC NON -ADDRESS, RED, WALL 30 0.0000 0.0000 0.1160 0.2320 4906-9127 2 A/V MC NON -ADDRESS, RED, WALL 75 0.0000 0.0000 0.2210 1 0.4420 5495 1 NAC EXPANSION PANEL 1 0.0750 0.0750 0.1750 0.1750 Peripheral Totals 0.0750 2.7150 Total Standby 0.1600 Total Alarm 2.9000 Standby Standby Alarm Alarm Battery Set #1 (Cabinet/Charger 1) Current Total Current Total Select ALL Power Supplies on this battery set: 4009 0.1600 2.9000 Total 0.1600 2.9000 Standby Time = 24 Hrs x 0.1600 = 3.8400 Standby Ah Alarm Time = 5 Min 0.08333 x 2.9 = 0.2417 Alarm Ah 4.0817 Additional Spare Capacity = 0% + 0.0000 4.0817 Battery Discharge Factor = 20% + 0.8163 Minimum Battery Required 2081-9272 6.2AH (2x) 4.8980 Battery Supplied 2081-9272 6.2AH (2x) a NAC71B - 4009 CIRCUIT SUMMARY & VOLTAGE DROP Plan Circuit Description Load % Drop NAC7B:V1 NAC7A SILENT KNIGHT TRIGGER SIG1 0.175A 0.03% NAC7B:V2 NOTIFICATION 7TH FLOOR CORE SIG2 1.020A 6.10% NAC7B:V3 NOTIFICATION 7TH FLOOR - NORTH SIG3 0.980A 5.93% NAC7B:V4 NOTIFICATION 7TH FLOOR SUITE 740 SIG4 0.540A 1 2.76% 2.715A Total NAC7B:V1 Distributed Load Voltage Drop Distributed Load Allowable % Drop: 16% Wire Res. Per Ft. 0.0029 @ 60' Celsius Wire Gauge: 14go Min. Device Voltage: 16.vdc Starting Voltage: 19vdc % Voltage Drop 0.03% Device # PID Normal Operation Distance (feet) Device Current Distance Device o tage Voltage At Device # PID Candela (feet) Current Drop Device NAC7B:V1-1 5495 5 0.17500 0.005 18.99 Totals:l 5 Ft. 10.175A I NAC7B:V2 Distributed Load Voltage Drop Allowable % Drop: Wire Gauge: Starting Voltage: 16% Wire Res. Per Ft. 0.0029 ® 60' Celsius 14ga Min. Device Voltage: 16.vdc 19vdc % Voltage Drop 5.93% Normal Operation Allowable % Drop: Wire Gauge: Starting Voltage: 16% 14go 19vdc Wire Res. Per Ft. 0.0029 @ 60' Celsius Min. Device Voltage: 16.vdc % Voltage Drop 6.10% Normal Operation Device # PID Candela Distance (feet) Device Current Voltage Drop Voltage At Device NAC' 6 V2-1 4906-9101 15cd 36 0.06000 0.215 18.79 NAC7B:V2-2 4906-9127 15cd 23 0.07500 0.344 18.66 NAC7B:V2-3 4906-9101 15cd 45 0.06000 0.576 18.42 NAC7B:V2-4 4906-9127 75cd 29 0.22100 0.716 18.28 NAC7B:V2-5 4906-9127 75cd 51 0.22100 0.896 18.10 NAC7B:V2-6 4906-9101 30cd 55 0.09400 1.019 17.98 NAC7B:V2-7 4906-9101 15cd 38 0.06000 1.083 17.92 NAC7B:V2-8 4906-9127 15cd 32 0.07500 1.126 17.87 NAC7B:V2-9 4906-9101 15cd 21 0.06000 1.145 17.86 NAC7B:V2-10 4906-9101 30cd 25 0.09400 1.159 17.84 Totals: 1 355 Ft. 11.020A NAC7B:V3 Distributed Load Voltage Drop Voltage Drop Allowable % Drop: Wire Gauge: Starting Voltage: 16% Wire Res. Per Ft. 0.0029 ® 60' Celsius 14ga Min. Device Voltage: 16.vdc 19vdc % Voltage Drop 5.93% Normal Operation Device # PID Candela Distance (feet) Device Current PID o tage Drop Voltage At Device NAC7B:V3-1 4906-9101- 11Ocd 34 0.25200 84 0.195 0.265 18.81 NAC7B:V3-2 4906-9127 1 10c 65 0.28500 0.06000 0.471 18.53 NAC7B:V3-3 4906-9101 30cd 102 0.09400 0.380 0.735 18.62 18.26 NAC7B:V3-4 4906-9101 15cd 15 0.06000 Z 0.766 NAC7B:V4-5 18.23 NAC7B:V3-5 4906-9101 15cd 55 0.06000 18.49 0.859 1 4906-9127 18.14 NAC7B:V3-6 4906-9101 15cd 11 0.06000 0.873 18.13 NAC7B:V3-7 4906-9101 30cd 30 0.09400 0.903 18.10 NAC7B:V3-8 4906-9127 15cd 46 0.07500 0.923 18.08 Totals:( 358 Ft. 10.980A NAC7B:V4 Distributed Load Voltage Drop Allowable % Drop: Wire Gauge: Starting Voltage: 16% go 19vdc Wire Res. Per Ft. 0.0029 0 60' Celsius in. Device Voltage: 16.vdc % Voltage Drop 2.76% Normal Operation Device # PID Distance Candela feet Device Current Voltage Drop Voltage At Device NAC7B:V4-1 4906-9127 30cd 84 0.11600 0.265 W 18.73 NAC7B:V4-2 4906-9101 15cd 37 0.06000 0.357 18.64 NAC7B:V4-3 4906-9101 15cd 11 0.06000 0.380 1 18.62 NAC7B:V4-4 4906-9101 30cd 42 0.09400 0.455 Z 18.55 NAC7B:V4-5 4906-9101 30cd 43 0.09400 0.507 18.49 NAC78:V4-6 1 4906-9127 1 30cd 1 24 1 0.11600 1 0.524 18.48 Totals: 1 241 Ft. 10.540A r o� co I­ CDCD ui z o d W w U) orjfm �oC0 w ,w O'er v C o Lo LU �0Uj pYcr LU in (0__j< Cn a 0 W V J L.L W W 0CL m Z CO Z w �- OL0 U U)0 Z cUN Q CD M 0 U LU 0 Y 2 U 0 U LU 0 � Of DRAWN BY: M. GERRONE CHECKED BY M. GERRONE ISSUE DATE: 1/23/15 JOB #: PROJECT #: 448:982542601 SIMPLEXGRINNELL © 2015 SYSTEM: FIRE ALARM SYSTEM SHEET: CALCULATIONS AND SCHEDULES \ DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) USE ONLY UL LISTED ARE ALARM SIGNALING LINE (ADDRESSABLE) CIRCUITS SHIELDING EXAMPLE TWISTED SHIELDED PAIR CABLE UL LISTED FIRE PROTECTIVE SIGNALING CABLES MAY BE SELECTED FROM THE SIMPLEXGRINNELL WIRE & CABLE TABLE, #WIRE TABLE CLASS 'A_ (TSP) FOR IDNETS, DATA COMM. +oo N L VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS A/C SUPPLY LINES, AUDIO, PHONE &SPEAKER ,� WIRING IN A ARE ALARM SYSTEM. r; u') m OR RETURN PRODUCT INFORMATION 1. MIN DISTANCE IN SLEEPING ROOMS IS 24" 610mm FROM CEILING TO THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS MIN. SIZE IS 18-2 AWG SOLID STP. co co ( ) DIFFUSER CUT WIRING TECHNIQUES FOR SHIELDED CABLE: I i E TOP OF LENS FOR 11 OCD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 r EXAMPLE: U�.L 2 #18-2 AWG SHIELDED • SHIELDS AND DRAINS MUST NEVER TOUCH GROUND. I 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24 T'WIST'ED -PAIR CABLE • MOST GROUNDS ARE DUE TO SHIELDING ISSUES. LL; 4' NOTE. MEASUREMENTS N (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3' MIN • MOST SHORTS ARE SHIELD TO CONDUCTOR. ( ) 102mm SHOWN ARE TO THE INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. (g14mm MIN) ( ) CLOSEST EDGE OF THE TRIM AWAY ONLY • BY CREATING A PROPER PROCEDURE FOR WIRE I Q° CEILING HANDLING WITH ADDRESSABLE CIRCUITS _ p DETECTOR. THE HIELD AND EEPSTHE DRAIN O MOST GROUNDS AND SHORTS CAN BE ELIMINATED. U °_ - - WIRE UNDAMAGED. •ALL UNSHIELDED WIRE MUST BE ENTIRELY IN GROUND CONDUIT. - ::�•• :::` � �, C3 • CONDUIT SYSTEM MUST HAVE A GOOD REFERENCE TO EARTH GROUND N CEILING MOUNTED L o FOR CEILING HEIGHTS LESS THAN 86" (2180mm), NFPA 72 AUDIBLE APPLIANCE SMOKE HEAT 4 • PIGTAILS, (T -TAP) WIRING IS PERMITTED TO ADDRESSABLE DEVICES N 000�, " / 102mm �SHIEU) FOR CLASS B CIRCUIT WIRING. woc L THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6 MIN (152.4mm MIN) DETECTOR ( ) 12 (MAX) _ :R(o 0 WITHIN 6" (150mm) OF .THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING pN w E .oLuW (305mm MAX) PREPARE THE CABLE BY EXAMPLE FOR HEAT DETECTORS REMOVING 2' TO 4' OF 4 WIRING LABELING p v ( ) ACCEPTED HERE NEVER HERE JACKET AS NEEDED. w> � 90 MIN 2286mm MIN � � ABOVE FINISHED FLOOR CD am 0 OTHER MOUNTING HEIGHTS SHALL BE DlscaRD ISMEE r ACE OO N FIFE F F ( GENERAL WIRING GUIDELINES REUSE INSULATION--�� SHIELD PERMITTED BY THE AHJ PROVIDING IT �I CLASS 'B' AUDIBLE/VISUAL MEETS THE SOUND LEVEL OUTPUT REQUIRED.) / I. ALL WIRING IS TO BE COPPER CONDUCTOR. ALL EQUIPMENT MUST + +& VISUAL ONLY WALL MOUNTEDBE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS TO EXIT DOOR RECOMMENDATIONS AND THE SPECIFICATIONS AND STANDARDSAPPLIANCES SMOKE/HEAT OF THE AUTHORITY HAVING JURISDICTION. THE INSTALLATION OF � DRAIN WIRE REVENT CONFUSION AND POSSIBLE 5' MAX. ALL WIRING, CABLE AND EQUIPMENT MUST BE IN ACCORDANCE RS, ALL WIRES MUST BE TAGGED. ( ) DETECTORWITH NFPA 70, NATIONAL ELECTRICAL CODE NEC), AND SPECIFICALLY WIRE LEGEND FOR TYPES. 1524mm WITH ARTICLE 760, FIRE ALARM PROTECTIVE SIGNALING SYSTEMS; WIRES MUST BE CONNECTED ( ) SEPARATELY UNDER TERMINALS. SYNCHRONIZE MORE THAN, DOOR ARTICLE 800, COMMUNICATION CIRCUITS, WHERE APPLICABLE. A CONTINUOUS WIRE LOOP TWO APPLIANCES IN ANY WIDTH 2. IF SHIELDED WIRE Is USED, THE FOLLOWING MUST BE.OBSERVED: DRAIN WIRE IS NOT ALLOWED. r FIELD OF VIEW. LESS 3 A. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND (+) (76mm) INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE. STRIP OFF APPROX. RED ONLY CLASS B IDNET, MAPNET OR o B. SHIELDS SHALL ONLY BE CONNECTED AT THE CONTROL UNIT. 1-2 INCHES OF PUSH REUSED INSULATION DATA COMM. CABLE MAY BE 2 SHIELD MUST NOT BE CONNECTED T0, OR TOUCH CONDUIT, ELECTRICAL BLACK INSULATION TO CAREFULLY DOWN INTO BOXES, OR ASSOCIATED HARDWARE AT ANY POINT. SLIDE ONTO DRAIN WIRE. JACKET. SECURE WITH T -TAPPED. IT MUST BE DONE 96" MAX (NFPA, ADA) 5" SIDE WALL C. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER ;, c`^ ELECTRICAL TAPE. IN A JUNCTION BOX WITH 2440mm HAN 1 MEGOHM TO EARTH. err CABLE STRAIN RELIEF I.E. ( MAX)) (127mm) D. ALL CONDUCTORS ARE TO BE FREE OF SHORTS AND GROUNDS. ,/ 8 CK CORD CLAMP/BUSHING, AND REF. 80" MIN IBC ABOVE FINISHED FLOOR MANUAL 3. UNDERGROUND WIRING MUST BE LISTED FOR APPLICATION AND FREE OF ALL WATER. / TAPE WRAPPED AS SHOWN HERE. (IBC) 4. WIRING OTHER THAN THAT CONNECTED TO ELEVATOR CABS MUST NOT BE RUN N TO TOP OF LENS PULL IN ELEVATOR SHAFTS REF.NFPA 70, ARTICLE 620 REDUCE EXPOSED WIRES TO 6 (2032mm MIN) ( )• � STATION 5. WIRING IN DUCTS, PLENUMS AND OTHER AIR HANDLING SPACES MUST BE LISTED ABOUT 5/16" TO 3/8' FOR r DRAIN WIRE REF. 96" MAX (IBC) 80" MIN ADA 2032mm MIN FOR PLENUM USE AND INSTALLED IN ACCORDANCE WITH NFPA 70, ARTICLE 300. INSERTION INTO BOX -TYPE N 6. SPLICING IS PERMITTED IN ACCORDANCE WITH NFPA 70. ALL JUNCTIONS MUST OR SCREW -CLAMP TERMINALS. STRIP THE INSULATED WIRES t (2440mm MAX) " (ADA) PHONE MAGNETIC BE INSULATED AS SOUNDLY AS THE ORIGINAL JACKET. CONTINUITY OF ANY SHIELD ABOUT 5/16" TO 3/8" FOR - 80 MIN (NFPA) (2032mm MIN) (WHERE USED) MUST BE MAINTAINED. ELECTRICAL TAPE, INSERTION INTO BOX -TYPE OR ABOVE FINISHED FLOOR JACK ,.� DOOR : x, SCREW -CLAMP TERMINALS ON g SECURE THE TO BOTTOM OF LENS 7. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 7 THE ADDRESSABLE DEVICE. O DRAIN WIRES INTO = HOLDER 8. THE COMMUNICATION CIRCUIT MEETS THE OPERATIONAL CHARACTERISTICS DEFINED FOR A STYLE 4 O y �,.. / THE CONNECTOR O a♦ AND STYLE 6 SIGNALING LINE CIRCUIT. MAXIMUM WIRE RUN NOT TO EXCEED 2500 FT. / APPROVED FOR FINISHED 9. ALL CIRCUITS ARE SUPERVISED AND POWER -LIMITED UNLESS OTHERWISE INDICATED. SHIELD WIRES ARE NOT SUPERVISED. THE PURPOSE. ® WALL 10. OPERATING POWER, FOR ZDNet DEVICES, MUST ORIGINATE FROM A POWER -LIMITED` POWER SUPPLY LISTED FOR FIRE WIRES MUST BE NOTE: REFER TO THE PROPER DEVICE PROTECTIVE SIGNALING USE OR, FROM THE F.A. CONTROL PANEL POWER SUPPLIES INDICATED IN THE APPROPRIATE ''TIGHT ENOUGH c 48 MAX ADA 1219mm DIAGRAM. MAXIMUM WIRE NOT TO EXCEED 1KM (3270 FT). --THE SHIELD/DRAIN IS NEVER INSTALLATION INSTRUCTIONS (ADA) ( ) CONNECTED TO THE DEVICE. TO HOLD SECURELY 11. WHEN COMMUNICATION WIRING OR OPERATING WIRING LEAVES THE BUILDING, OVERVOLTAGE PROTECTORS ARE AND NOT SUP OUT FOR BACKBOX MOUNTING HEIGHT. REQUIRED; USE 2081-9044, INSTALL ONE WHERE IT LEAVES THE BUILDING AND ONE WHERE IT ENTERS THE NEXT BUILDING. 0 OF THE CONNECTION. 48 MAX (NFPA, ADA) (1219mm MAX) . TO PREVENT CONFUSION AND POSSIBLE ERRORS TAG ALL CONDUCTORS CODE AT INSTALLATION TO IDENTIFY ENSURE BARE DRAINS FINISHED 42" MIN NFPA 1067mm MIN CIRCUIT ASSIGNMENT, POLARITY AND IN OR OUT DIRECTION OF THE WIRING. LOG ON AS-BUILTS ® ARE SECURED AND FLOOR (� ) ( ) 13. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. UNABLE TO MAKE MEASUREMENTS SHOWN ARE SIMPLEXGRINNELL IS NOT RESPONSIBLE FOR ELECTRICAL CONTRACTOR'S WIRE CONDITIONS. TRIM THE BARE DRAIN EXTERNAL CONTACT. TO TOP OF PULL HANDLE 14. IDNet COMMUNICATION LINE SPECS.: TO ABOUT 1-1/2'. JOIN SEE NOTE 2 MAX. 36 VDC 0 .5A 15. IDNET MAXIMUM NUMBER OF DEVICES: THEM WITH AN ELECTRICAL o 3333 BAUD NON -CODED 250 CONNECTOR LISTED AND a 33fz MAX. LINE RESISTANCE CODED PIEZO BASES 43 MAX. APPROVED FOR WIRE SPLICING. 217 ADDRESSES STILL AVAILABLE FOR OTHER DEVICES. o END—OF—LINE RESISTOR CODES 4090-9002 IDNet SLC, INDIVIDUAL ADDRESSABLE OUTPUT MODULE RELAY (AOM) PRODUCT INFORMATION s FEATURES: • UL LISTED NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION • A SINGLE ADDRESSABLE POINT BOTH CONTROLS A 2A FORM INSTRUCTIONS FOR PROPER TERMINATIONS. "C' CONTACT AND TRACKS ITS STATUS • COMPATIBLE WITH SIMPLE( MODEL 4010 AND 4100 ADDRESSABLE FIRE ALARM CONTROL PANEL 3 * USE WITH RETROFIT OR HIGH CURRENT MODULE • LATCHING RELAY DESIGN ALLOWS DATA AND POWER TO BE BOTH SUPPLIED BY ZDNet COMMUNICATIONS 3 REFERENCE • COMPACT, SEALED CONSTRUCTION: MODEL NUMBER OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE - SCREW TERMINALS FOR WIRING CONNECTIONS - REDUCES DUST INFILTRATION 4081-9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) SPECIFICATIONS: o N.O. INITIATING 4004*, 4004R, 4005*, 4006, • RELAY IAM POWER: SUPPLIED BY ZDNet COMMUNICATIONS 4' SQUARE X 2 1/8' DEEP BOX PULL, SMOKE, HEAT, • RELAY IAM CONTACTS (FORM "C', SPDT) SUPPLIED BY CONTRACTOR 4100, 4120, 41000, ZAM S • POWER LIMITED RATING: 2A 0 24VDC, TRANSIENT SUPPRESSED 4081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER, ETC. LOADS, 1A 0 24VDC FOR INDUCTIVE LOADS 0 d- 24 PT. 1/0 SWITCH SUPV. 4605-7401, 4100 SERIES • NON,DsOW LIMITE0 24 DCAOR INDUCTIVE LO4VAC, TRANSIENT SUPPRESSED ADS CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM (EOLR) 4081-9003 733-896 4.7X YELLOW VIOLET RED GOLD N/A 1/2 •WIRE CONNECTIONS: SCREW TERMINALS FOR IN/OUT NOTIFICATION DACT 2080-9024 * WIRING, #18 TO #14 AWG WIRE • •ui • COMPATIBLE WITH SIMPLEX 2081-9044 OVER VOLTAGE PROTECTORS N.O. INITIATING 4004, 4005, • DIMENSIONS: 4 1/8"H x 4 1/8'W x 1 3/8'D (105mm x 105mm x 35mm) 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, HEAT, 4090-9001 IDNET IAM • HOUSING MATERIAL: BLACK THERMOPLASTIC o -- 72 WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PTI 0 • MOUNTING PLATE MATERIAL SHEET METAL, GALVANIZED RELAY IAM a 4-20MA ZAM TROUBLE • TEMPERATURE RANGE: 37 F TO 120' F (0' C TO 49' C) INTENDED FOR INDOOR OPERATION CURRENT LIMITED N.O. INITIATING • HUMIDITY RANGE UP TO 93% RH AT 100' F (38' C) 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 (IN LINE) 4090-9001 IDNET IAM DESCRIPTION: BACK BOX COVER OPTIONS; m IDNet SLC RELAY MODULES ALLOW THE SIMPLEX FIRE ALARM SEMI -FLUSH TRIM PLATE 4090-9801 (SHOWN) 4081-9006 733-890 560 n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING EOLR 4005*, 4090-9001 IDNET IAM WITH LIGHT PIPE FOR LED VIEWING Q, / (EOLR) CONTROL PANEL TO CONTROL A REMOTELY LOCATED FORM SURFACE TRIM PLATE 4090-9802 w 'R 4100, 41 OOU C CONTACT USING ZDNet ADDRESSABLE COMMUNICATIONS WITH LIGHT PIPE FOR LID VIEWING FOR BOTH DATA AND POWER. TYPICAL APPLICATIONS 2 -GANG BACK BOX COVER 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 WOULD BE FOR SWITCHING LOCAL POWER FOR CONTROL SUPPLIED BY CONTRACTOR W Q FUNCTIONS SUCH AS ELEVATOR CAPTURE, OR CONTROL OF 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008, HVAC COMPONENTS, PRESSURIZATION FANS, DAMPERS, ETC. 4009, 4010, 4100, 41000 RELAY STATUS IS ALSO COMMUNICATED REQUIRING ONLY ONE o o (p 0 0 - o DEVICE ADDRESS, 4081-9009 733-912 205 RED BLACK BLACK GOLD N/A 1 TO MR -101 RELAY COIL 4005 8 POINT 1/0 —1 WIRING NOTES: ® © ® Im ® ® ® Im p N.C. INITIATING (ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM 1. ZDNet LINES ARE TO BE #18 AWG TWISTED PAIR (CONSULT NORMALLY CLOSED (N.C.) NORMALLY CLOSED (N.C.) I co SG SALES ENGINEERING FOR EXCEPTIONS. 4081-9010 733-973 1 K BROWN BLACK RED GOLD N/A 1 24 PT. I/O (ACROSS CONTACTS) 4605-7401, 4100 SERIES 2. MAXIMUM ALLOWABLE UNE RUN, FROM THE F.A.C.P. TO THE FARTHEST _ _ _ COMMON COMMON O CURRENT LIMITED N.O. INITIATING DEVICE, NOT TO EXCEED 2500 FEET. r �• NORMALLY OPEN (N.O.) r NORMALLY OPEN (N.O.) � (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM 3. MAXIMUM QUANTITY OF DEVICES PER CIRCUIT: CONTROL PANEL I r r -�"- I r- - oL� "' MODULE DEPENDENT I I I r - ��� NOT USED I ( I I- NOT USED , ^ m M s 4081-9011 733-974 100n BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 4. CONTRACTOR WIRING TO RELAY CONTACTS IS UNSUPERVISED. L J z cel E 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 USE #14 AWG WIRE TO LOCAL CODE I I I I ° Lu CV - o / / 5. RELAY CONTACTS RATED 2A, 24VDC (1A FOR INDUCTIVE LOAD) I I I I 7 �. ° 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1/2 RELAY CONTACTS RATED 0.5A 120VAC (NON POWER LIMITED) I I I I Z w rn FOR POWER -LIMITED OPERATION, POWER MUST BE PROVIDED I I I (- - - - - - - - - - - - - - - - - I- (-i I ° o N.C. INITIATING FROM FACP OR POWER -LIMITED POWER SUPPLY LISTED FOR ARE ADDRESS SLEETING UNDER (� 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM PROTECTIVE SIGNALING USE. I L I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ i i RE -SEALABLE LABEL O Z O o 6. SEE INSTALLATION INSTRUCTIONS 574-184. I I CURRENT LIMITED N.O. INITIATING 7. IF SHIELD IS PRESENT, CONNECT TO THE OUTGOING ZDNet SHIELD C , ---I � 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N A 1 2 4090-9001 IDNET IAM PRIMARY I I I I SECONDARY IDNet SLC LINES v / / (SECURITY MONITORING EOLR) TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE ZDNet SLC LINES 0 O - ZDNet CHANNEL METHOD OF SPLICE DETERMINED BY AHJ. ©©© OPTIONAL SHIELD 0 ® ® ® U O Q 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 8. WHEN CONNECTED TO A NON POWER -LIMITED SOURCE, THE WIRING S 0 S ,4---I� z o O MUST MAINTAIN A MINIMUM 1/4 INCH SEPARATION FROM ZDNet WIRING. J �-- m 01 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 9. WHEN USED WITH NON POWER -LIMITED SOURCE, THE 'POWER LIMITED RI IB R I I B ►� 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 WIRING" INDICATION ON THE DEVICE LABEL MUST BE OBLITERATED. I I I I 10. WHEN BOTH POWER -LIMITED AND NON POWER -LIMITED SOURCES o 378-090 8.2K GRAY RED RED GOLD N/A 1 /2 SECURITY MONITORING (EOLR) 4100, 41 OOU ARE PRESENT, USE TYPE FPL, FPLR OR FPL? POWER LIMITED + - + - N a 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. SERIES 4100 41000 CABLE FOR POWER -LIMITED CIRCUITS. / / ( ) 11. MAXIMUM TOTAL WIRE INCLUDING ALL T -TAPS ON CIRCUIT, FROM THE FROM PREVIOUS SLC DEVICE ZDNet SLC E 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 41000 F.A.C.P. NOT TO EXCEED 10,000 FEET OR .58uF. (CLASS B ONLY) OR F.A.C.P. © TO F.A.C.P. 0 3 12. REFER TO FIELD WIRING DIAGRAM 842-073TM 0 8 N TrueAlert NON—ADDRESSABLE 'QULTI—CANDELA VISIBLE NOTIFICATION APPLIANCE TrueAlertw NON—ADDRESSABLE MULTI—CANDELA AUDIBLE/VISIBLE NOTIFICATION APPLIANCE N PRODUCT INFORMATION WHEN SURFACE MOUNTING USE PRODUCT INFORMATION < (WALL MOUNT) RED SKIRT NO. 4905-9937 OR 4" SQUARE x 1-1/2' DEEP BOX (ELECTRONIC HORN W/STROBE) FEATURES: WHITE SKIRT N0. 4905-9940 FEATURES: WHEN SURFACE MOUNTING USE • UL LISTED TO STANDARD 1971 4905-9931 ADAPTER PLATE • CLASS B (STYLE Y) OPERATION REQUIRES CONNECTION RED SKIRT NO. 4905-9937 (RED m 0 2975-9145 BOX � 4' SQUARE x 1 1/2" DEEP BOX o • ADA COMPATIBLE TO A COMPATIBLE SMARTSYNC NAC OR TO WHITE SKIRT NO. 4905-9940 (WHITE Z SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: o SMARTSYNC CONTROL MODULE (SCM) 4905-9938 IMPORTANT! O o • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE WALL MOUNT INSTALLATION •SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE °� 4905-9938 SCM OR 41000 SERIES FIRE ALARM HEIGHT REFERENCE w FOR CLASS B OR CLASS AOPERATION - 4905-9961 OPTIONAL WIRE o W GUARD (SHOWN HERE FOR CONTROL PANEL NAC'S o (9 • SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE REFERENCE ONLY, CAN BE ° ELECTRICAL BOTTOM OF LENS CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS O USED ON OTHER MOUNTING SPECIFICATIONS: Box ouruNE Is EITHER EVEN wITH OPTIONS ° OR SLIGHTLY ABOVE o BOTTOM OF m SPECIFICATIONS: — - ) • HOUSING DIMENSIONS (INCLUDING LENS) : 5 1/8"H X 5" W X 2 3/4'D COMPATIB E BOXES o w • HOUSING DIMENSIONS: 5-1/8" H X 5" W X 2-3/4" D (130mm X 127mm X 70mm) o o� • TEMPERATURE RANGE: 32' F TO 122' F (0' TO 50' C) • HUMIDITY RANGE: 10% TO 93% NON -CONDENSING AT 100' F (38' C) o o� TEMPERATURE RANGE: 32'F TO 122'f (0 TO 50'C) (� Z • HUMIDITY RANGE: 10% TO 93% NON -CONDENSING AT 109F (38'C) • TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER o ® o CIO • TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN/OUT WIRING. NFPA 72 REQUIRES THAT TERMINAL FOR IN/OUT WIRING. o o ALTERNATE BACK BOXES p 80" a THE ENTIRE ENS BE NOT o 1. 2 GANG 1-1 2 DEEP BOX MIN. LESS THAN aa° AND NOT WIRING: / n GREATER THAN 96' ABOVE O ALTERNATE. BACK BOXES w E 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. STANDARD ELECTRICAL BOX MOUNTING 2. SINGLE GANG 1-1/2" DEEP BOX THE FINISHED FLOOR. 1. 2 GANG 1 1/2" DEEP BOX � 4" SQUARE BOX, 1-1/2" DEEP c 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP 4905-9961 OPTIONAL WIREM 11 11 11 11 O 2 SINGLE GANG 1 1/2' DEEP BOX = o WIRES UNDER TERMINALS. GUARD (SHOWN HERE FOR 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER -LIMITED. REFERENCE ONLY, CAN BEUSED 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. OPTIONS) OTHER MOUNTING g I �I� SEMI -FLUSH MOUNTING _ y a STROBE: �p _ SURFACE MOUNTING p 2975-9145 BOX SEMI -FLUSH MOUNTING N • RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 Lo ULC LISTED: 20 VDC TO 30 VDC PER ULC S526 -M878 o • FLASH RATE: 1 H SURFACE MOUNT ADAPTER SKIRT HORN 0 o € UD • SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. 1 5/8" (41 mm) DEEP. - SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 Hz SWEEP, w Y C) CONDUIT CUTOUTS ARE PROVIDED MODULATED AT 120 Hz RATE 4905-9931 ADAPTER PLATE N *CURRENT DRAWS REFLECT STROBE FLASHING ON ALL FOUR SIDES. TO ADDITIONAL NOTIFICATION s APPLIANCE DEVICE OR RETURN ( ) TO ADDITIONAL NOTIFICATION V m HOUSING LETTERING STROBE T HORN SOUND OUTPUT RATINGS ®10 FT. 3m MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC TO FACP FOR STYLE Z APPLICATION 4906-9101 RED WHITE 15cd 60 mA 53 mA 40 mA IF LAST DEVICE ON CIRCUIT IN A VOLTAGE 16 VDC 24 VDC 33 VDC APPLIANCE DEVICE OR RETURN p 30cd 94 mA 84 mA 63 mA —i STYLE Y APPLICATION PLACE A TO FACP FOR STYLE Z APPLICATION o 75cd 186 mA 165 mA 124 mA TERMINALS 3 & 4 ARE NOT USED + 10K 1 /2W END -OF LINE RESISTOR SOUND TYPE * STEADY CODED STEADY CODED STEADY CODED + If LAST DEVICE ON CIRCUIT IN A z 11Ocd 252 mA 224 mA 168 mA STYLE Y APPLICATION PLACE A REVERBERATE CHAMBER 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA TERMINALS 3 & 4 ARE NOT USED ( 10K 1/2W END -OF LINE RESISTOR DRAWN BY: M. GERRONE 4906-9103 WHITE RED 15cd 60 mA 53 mA 40 mA I ( ( UL 464 TEST CHECKED BY M. GERRONE 30cd 94 mA 84 mA 63 mA c~i� 75cd 186 mA 165 mA 124 mA I O ® I I 4 ®3 ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA I I I I ISSUE DATE: 1/23/15 g 110cd 252 mA 224 mA 168 mA I I * CODED VALUES ARE TYPICAL OF THE OUTPUT MEASURED WITH A TEMPORAL 4 ® 3 ( ® ® 3 JOB #. o O O I LUO O O CODED OR A MARCH TIME CODED PULSE AND WITH A SOUND LEVEL METER I I PROJECT #: 448:982542601 8 FROM A IMPORTANT! SMARTSYNC NACBLE OR FROM + ®O ®O READING ON A "FAST" SETTING. UNDER THE SAME TEST CONDITIONS, CODED O O IL O c WALL MOUNT INSTALLATION SMARTSYNC CONTROL �-DHORN OUTPUT L"PEAK" SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. FROM A COMPATIBLE + ®QQ ®O SIMPLEXGRINNELL O 2015 E m O (- O L SIMPLEX SMARTSYNC HEIGHT REFERENCE MODULE (SCM) 4905-9938 — ®® ®® O L O L SYSTEM: OR SIMPLEX 4905-9914 STROBE NAC OR FROM ®® ®O s o ELECTRICAL BOTTOM OF ENS OR 9922 SYNC CUBE - RATED VOLTAGE RANGE: UL REGULATED 24VDC PER UL 1971 SMARTSYNC CONTROL — FIRE ALARM SYSTEM BOX OUTLINE IS EITHER EVEN WITH ULC: 20VDC TO 30VDC PER ULC S526 -M878 MODULE (SCM) 4905-9938 OR SLIGHTLY ABOVE — FLASH RATE: 1 HZ SHEET:BOTT3 OF COMPATIBLE BOXES - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. N z *CURRENT DRAWS REFLECT STROBE FLASHING AND HORN ON. HOUSING LETTERING RMS CURRENT 0 QQO - O0 O MODEL NUMBER COLOR COLOR RATING 1 4 V WIRING TYPICALS 0 4906-9127HI c mA mA mA O Q O NFPA 72 REQUIRES THAT 75 cd 11 m 1 m m ° N 80" THE ENTIRE LENS BE NOT cd mA 6 m -1 T4 mA 75 LESS THAN 80' AND NOT INTENSITY SELECTION 15 11 cd m m 1 mA 30 a° ii MIN' GREATER THAN 96° ABOVE PLUG, ACCESSIBLE ONLY 4906-9129 W I 15cd mA 67 mA 50 mA INTENSITY SELECTION 15 u E w THE FINISHED FLOOR. FROM REAR OF HOUSING; cd 11 mA 103 mA 77 mA PLUG, ACCESSIBLE ONLY _ c FACTORY SETTING IS 15cd cd mA 196 mA 147 mA FROM REAR OF HOUSING; a 11 cd mA 253 mA 190 mA FACTORY SETTING IS 15cd u STROBE INTENSITY VIEWING SLOT STROBE INTENSITY o E C14VIEWING SLOT FA -701 z X a E � m — .c