Plans LS2014 00018 _ I i _ CE1 JAN 3 0 ?414 It Col LOm CITY Of`I TGA V BUILDING DIVIS110 coM �� w Z QaLL LL w C3- U ~ ~� I11 �� - o OCLrn 3C::) OC m LuOLN UJ CD LINCrr^� C [n OM vJ F �CnW U �pU L , LnW> 4�1N GYM KPD INSURANCE SUITE 200 ff^ Lij u co V) FIRE ALARM SYSTEM 1 SITE INSTALLER DRAWING INDEX DWG# DESCRIPTION LINCOLN 1 CAPITOL ELECTRIC FA-001 COVER SHEET FA-002 GENERAL INFORMATION 10300 SW GREENBURG RD 11401 NE MARX ST FA-101 DEVICE PLACEMENT PLAN FA-701 WIRING TYPICALS TIGARD , OR 97223 PORTLAND , OR 97220 -- PHONE : 503-255-9488 CONTACT: DAN WILSON OWNER GENERAL CONTRA C TOR SHORENSTEIN REALTY SERVICES RUSSELL CONSTRUCTION o 0 N 10220 SW GREENBURG RD 20915 SW 105TH W PORTLAND , OR97223OR97062 � w U � Z � m CO Z :D w " UJ ry ry pZ � oo Up oo � Z � v C5 0 3 3 0 c 0 N N F_ Z CC LL W 2 LL m LuL Q Z c O J U w { Y - S U L) CD w 6305 SW ROSEWOOD ST, SUITE A o LAKE OSWEGO, OR 97035 u OFFICE COPY L<ItI I ItI I I I co PHONE:O N E: 503-683-9000 `CIT CSF TIGARD DRAWN BY: R. HERMANT z SERVICE: 503-683-9001 Approved..!__: ____,__ "' a Conditionally Approved _ CHECKED BY: J. JOHNSON For only the work as described in: ISSUE DATE: 1/30/14 cf)< n ell : 503-675-6521 �i= n�lr rdo. FP zv,�—o d /g JOB#: See Letter to:Follow________________________ t �. gn=,ch-------_--------- PROJECT#: 448:975653601 Job C,de_Q_g �c7_ SIMPLEXGRINNELL© 2013 L'y: SYSTEM: TM FIRE ALARM SYSTEM Safer. Smarter. co. Sol r? /� � SHEET: _SA L ES REPRESENTA TI VE DRA WINGS PREPARED B Y COVER SHEET BRYAN ADAMS JEFFRY JOHNSON N u W503-683-9000 N I C ET LEVEL 111 #121846 FA-001 j GV C' X i O M I I GENERAL MOTES SYSTEM DESCRIPTION SCOPE OF WORK SYMBOL KEY co U'> �Lo � CD � 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF OCCUPANCY TYPE: B BUSINESS GROUP wo CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. SPRINKLER PROTECTION: BUILDING IS NOT SPRINKLED a u 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJORLu c 3 DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AND RELOCATE EXISTING DEVICES AS _U- TO IMPAIR THE CONSTRUCTION SCHEDULE. SHOWN ON DRAWINGS. LEGEND it o 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING FIRE ALARM SYMBOLS L_EG EN D '� oo"o AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY DESIGN IS FOR THE NOTIFICATION OF THE LINCOLN 1 SUITE 200 AREA OF WORK. ooM AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. SYMBOL DESCRIPTION M 0 D E L BAC K B 0 X oo W O �* cn c.�M 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR ALL NEW WIRING TO BE CLASS B. CD INSTALLATION. F- ui NAC EXTENDER PANELo fu 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE co oY� BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NAC DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELL tQ o c�o:5v ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO MANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. SMOKE SENSOR / BASE SIMPLEX 4098-9714 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO ® SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. RI RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8" DEEP W/TWO GANG COVER 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC. FIRE ALARM APPLICABLE CODES & STANDARDS DH DOOR HOLDER EXISTING 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE ® CEILING MOUNT MULTI-CANDELA V/0 WHITE SIMPLEX 4906-9104 HANDY BOX 1 1/2" DEEP FPLP. C # =CANDELA RATING 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN OREGON FIRE CODE, 2010 EDITION VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET OREGON MECHANICAL SPECIALTY CODE, 2010 EDITION EC CEILING MOUNT MULTI-CANDELA A/V WHITE SIMPLEX 4906-9130 4" SQUARE BOX 1 1/2" DEEP LOCATIONS. # =CANDELA RATING 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH OREGON ELECTRICAL SPECIALTY CODE, 2010 EDITION NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. NATIONAL FIRE ALARM CODE (NFPA 72), 2010 EDITION END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. EOLR END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 SUPPLIED BY SIMPLEXGRINNELL 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. NOTE: EXISTING DEVICES SHOWN SHADED FOR REFERENCE. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. WIRE SCHEDULE ABBREVIATIONS LEGEND RISER DIAGRAM AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM - - - RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM GENERAL NOTES: RL = RELOCATED DEVICE N/A = NOT APPLICABLE 1. DEVICES SHOWN ARE TYPICAL SEE FLOOR PLAN FOR RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER QUANTITY AND LOCATION. V WP = WEATHERPROOF NDU = NETWORK DISPLAY UNIT N5 � �® EOLR XP = EXPLOSION PROOF NEC = NATIONAL ELECTRICAL CODE 2. ALL WIRING SHALL COMPLY WITH NFPA 70, ARTICLE 760, C C C FIRE ALARM WIRE LIST (POWER LIMITED) NFPA = NATIONAL FIRE PROTECTION ASSOCIATION POWER LIMITED SYSTEMS. V O AFF = ABOVE FINISHED FLOOR NIC = NOT IN CONTRACT 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. N6 �(� EOLR O V VISUAL/SIGNAL CIRCUIT - 2 CONDUCTOR 14 AWG SOLID AHJ = AUTHORITY HAVING JURISDICTION NPU = NETWORK PROCESSING UNIT NAC2C L `' ' �1 C Q NON-PLENUM RATED: FPLR CONDUIT ONLY: THHN PLENUM RATED: FPLP ALM = ALARM NTS = NOT TO SCALE 4009 V BELDEN 512OUL (2) #14 AWG (RED/BLACK) BELDEN 612OUL ANN = ANNUNCIATOR PAP = PRE-ACTION PANEL C�I AREA=0.0356 SQ. INCH AREA=0.0097 SQ. INCH (EACH) AREA=0.0330 SQ. INCH ********** REFER TO SIGNAL CIRCUIT DISTANCE CHART ********** BMS = BUILDING MANAGEMENT SYSTEM SCC = STATUS COMMAND CENTER N7 SPARE CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA CBC = CALIFORNIA BUILDING CODE SLC = SIGNALING LINE CIRCUIT W 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * CD = (eg. 15CD) CANDELA SMK = SMOKE KEYED NOTES �--- 3�4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * CSFM = CALIFORNIA STATE FIRE MARSHALL SUPV = SUPERVISORY N8 SPARE 1 ' 0.34 SQ INCH * 2" 1.34 SQ INCH * DET = DETECTOR TAC = TRUEALERT ADDRESSABLE CONTROLLER O TIE INTO EXISTING N5 CIRCUIT. SEE FA-101 FOR * 40% FILL PER N.E.C. DGP = DATA GATHERING PANEL TRBL = TROUBLE CIRCUITING. MAINTAIN SUPERVISION. 1201'.AC �^ THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED EOL = END of Ts = TAMPER SWITCH EPO = EMERGENCCYY POWER OFF TYP = TYPICAL ELECTRICAL CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. FACP = FIRE ALARM CONTROL PANEL LION = UNLESS OTHERWISE NOTED 2TH FLOOR W ALTERNATE SUPPLIERS MAY BE SUBSTITUTED PROVIDING EQUIVALENT FATC = FIRE ALARM TERMINAL CABINET VCC = VOICE COMMAND CENTER CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS CAPACITANCE FBO = FURNISHED BY OTHERS VT = VALVE TAMPER U BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL FCC = FIRE COMMAND CENTER WF = WATER FLOW z FAA = FIRE ALARM ANNUNCIATOR W = (eg. 1/2W) WATT 0 TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. FTR = FIRE ALARM TRANSPONDER W/ = WITH Q w FSD = FIRE SMOKE DAMPER W/O = WITH OUT Iv- ry m M W N DEVICE ADDRESSING LEGEND SEQUENCE OF OPERATION z p _ zR�: 0 Up ooW ZrL zo < .j J CD � CONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL 0 O E NOTIFICATION APPLIANCE CIRCUIT DEVICE DESIGNATOR OJQJ` � 5 N2- 15 k. P G J O O �. O �,Q' � �Q� 0CD 19- NOTIFICATION DEVICE Q SYSTEM INPUTSI A I B I C D E F G H I J K L M N 0 P Q R S T U V ' W X Y Z AA AB AC AD AE AF AG AH REMARKS 1 SMOKE SENSOR DETECTOR • • 1 1 2 MANUAL PULL STATION • • • • • • • • • 2 cc 3 DUCT SENSOR DETECTOR • • • • • • . • 3 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • • • • • m 4 0 5 1 ELEVATOR LOBBY SMOKE DETECTORS EXC. MAIN FLR. • • • • • • • • • + • • • • 5 > ADDRESSABLE CARD (IDNET OR MAPNET) 6 ELEVATOR MECH. ROOM HEAT DETECTOR • • • • • • • • • • • • • 6 DEVICE ADDRESS 7 ELEVATOR MECH. ROOM SMOKE DETECTOR 7 z • • • • . • • cn 8 ELEVATOR SHAFT HEAT DETECTOR • • • • • • • • • • • • • g o M2- 1 9 ELEVATOR SHAFT SMOKE DETECTOR g 10 ELEVATOR POWER MONITOR • • • • • • 10 ADDRESSABLE DEVICES NUMBERING 111 FIRE ALARM AC POWER FAILURE • • • • • • 11 w 12 FIRE ALARM SYSTEM LOW BATTERY • • • • 12 13 OPEN CIRCUIT OR GROUND FAULT • • • • 13 14 CLASS B NOTIFICATION CIRCUIT NAC - SHORT • • • 14 15 15 0 16 16 171 17 cli 18 18 W �;, 19 19 q 20 20 0 21 21 r 22 22 D N 231 1 23 co 24 24 25 25 0 26 26 Lu z 27 27 28 28 DRAWN BY: R. HERMANT a29 29 CHECKED BY: J.JOHNSON 30 30 ISSUE DATE: 1/30/14 -' 31 31 JOB#: 32 3 PROJECT#: 448:975653601. A B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH SIMPLEXGRINNELL© 2013 SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION N W Q x FA-002 0 co C:) CD GENERAL NOTES: 1� rn M� 1. EXISTING DEVICES SHOWN SHADED FOR co`l) co Cl) REFERENCE. w z C3O Q O w U ~ U� Oj 15 O0A 0000 LU 0 0C7ch vJ C/)LU L, U w�> N HYD'_' � N25-8 15 t5 EOLR � C N25-2 �( NAC-2 BATTERY CALCULATIONS - 2ND FLOOR Standby Total Alarm Total r ( Module Description Qty Current Standby Current Alarm - _-- Panel Equipment LA rP-- -- 4009-9201 4009 IDNET NAC EXTENDER, 120 VAC 1 0.085 0.085 0.185 0.185 V i°� Total Panel Stby 0.085 Total Panel Alarm 0.185 V Notification A fiance Circuits From NAC Schedule 3.203 75 \V - V Total Periph Stby 0.000 Total Periph Alarm 3.203 F-1 N24-15 V V N24 18 Y P 0.085 P 3.388 OPEN OFFICE C i t5 30 EOLR 30 30 75 Total Standby Ams Total Alarm Am s 201 SUITE i N24-16 C N25-1 x( N25-7 �( SUITE i N24-17 C C C C 70 V 280 DN. SUITE Standby Alarm E� �ii:LD V Qty Current Current ra V 271 Control Panel, Power (Master Power Supply) 0.085 0.185 UP Power For External Peripheral Devices 0.000 3.203 :�� 0.085 <-- Totals --> 3.388 --=- Standby Time = 24 Hrs 1.951 Standby Ah am F 15 15 M2-35 15 `� Alarm Time = 5 Mins. 0.270 Alarm Ah M2-39 N24-12 M2-37 O N24-7 ® N25-3 V ITE Battery Supplied 2081-9272 6.2AH 3.488 Total Ah 30 M2-3$ \ C C V ( C OFFICE N24-14 � - - 15 I F M2-36 \ 201 V 65 OFFICE SUITE II 15 24-6 C V DN 203 V N24-9 C 7 M r31 Q 75 0 I z N25-6 15 OPEN C V } N24-10 30 V M2- M H. ® UP I N24-11 �` V DH D M2-30 I I �._ ---..__.-..- �� OFFICE200 C OPEN OFFICE I M2-41 OFFICE WORKROOM 201 75 V V 15 ; OFFICE NAC-2 NOTIFICATION APPLIANCE CIRCUIT SCHEDULE 204 N24-2 I\ 202 N24-8 15 \ PLAN CKT PANEL CIRCUIT DESCRIPTION # OF DEVICES CURRENT A 205 / V M2-33 N24-1 C SERVER V I I ` C j C LJ` 205 N5 NAC 1 2ND FLOOR WEST NOTIFICATION 13 1.752 ®SUITE � j N6 NAC 2 2ND FLOOR WEST NOTIFICATION 11 1.451 OFFICE '� L \- \ N7 NAC 3 SPARE 0 0.000 L C N8 I NAC 4 ISPARE 0 0.000 207 N24-13 � C I � 0 � � � V N25- 5 OFFICE OFFICE I 0 � OFFICE I 15 203 202 1 O C 15 N24-3 BREAK 203 DECK M2-40 ® M2-34 )Z( , 15 , 204 DECK RI N24-5 C V 24-4 \ C\ VOLTAGE DROP CALCULATIONS - N5 WIRE GAUGE 14 AWG 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDC MINIMUM DEVICE VOLTAGE 16 VDC PERCENTAGE VOLTAGE DROP 12% D DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT Q NUMBER NUMBER FT CURRENT A CURRENT A DROP V DEVICE V N N5-1 4906-9130 15 24 0.086 1.752 0.26 20.14 ( I N5_2 4906_9104 15 36 0.075 1.666 0.37 19.77 Uj N5-3 49b6-9130 110 45 0.320 1.591 0.44 19.33 N5-4 1 4906-9104 15 41 0.075 1.271 0.32 19.01 N5-5 4906-9130 75 31 0.250 1.196 0.23 18.79 N5-6 4906-9104 15 40 0.075 0.946 0.23 18.55 \ N5-7 4906-9130 75 30 0.250 0.871 0.16 18.39 ^ N5-8 4906-9104 15 36 0.075 0.621 0.14 18.26 V, N5-9 1 4906-9130 30 26 0.132 0.546 0.09 18.17 N5-10 4906-9130 30 50 0.132 0.414 0.13 18.04 Uj N5-11 4906-9130 30 35 0.132 0.282 0.06 17.98 U C) N5-12 4906-9104 15 30 0.075 0.150 0.03 17.95 01:� N5-13 4906-9104 15 45 0.075 0.075 0.02 17.93 Cr) m CO LU C-4 W ~ \ i _ VOLTAGE DROP CALCULATIONS - N6 \ U) rn WIRE GAUGE 14 AWG z 0 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS O O STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDC � MINIMUM DEVICE VOLTAGE 16 VDC Q O C:) M PERCENTAGE VOLTAGE DROP 10% Z ° I DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT z «� DECK CONFERENCE ROOM110 � NUMBER NUMBER (FT) CURRENT A CURRENT A DROP V DEVICE V V M1-39 ® � N5-3 N6-1 4906-9104 15 31 0.075 1.451 0.28 20.12 C N6-4 75 N6-2 4906-9130 15 45 0.086 1.376 0.38 19.74 0 AREA OF WORK N5-4 �1 C I N6-3 4906-9130 75 35 0.250 1.290 0.28 19.47 T 75 C V N6-4 4906-9104 75 63 0.233 1.040 0.40 19.06 \ N5-5 ---- -- N6-5 4906-9104 15 41 0.075 0.807 0.20 18.86 7 OFFICE V ® N6-6 4906-9130 30 36 0.132 0.732 0.16 18.70 3 211 \ C M1-38 ELE ORS 75 3 i N6-7 4906-9104 15 40 0.075 0.600 0.15 18.55 L N6-3 N6-8 4906-9130 75 49 0.250 0.525 0.16 18.39 H EDF CSUITE N6-9 4906-9104 15 34 0.075 0.275 0.06 18.34 V i ��0 V N6-10 4906-9104 30 41 0.125 0.200 0.05 18.29 DN. V N6-11 04 4906-9115 25 0.075 0.075 0.01 18.27 SI N5-2 C M1-30 rBREA Q \ X00 202 NM1-34 c, M1 1 W OPENC\\\ 15 F TELE. z 30 N5-6 M1-32 V )c( N6-6 OFFICE 75 RECEPTION HALL 5 N6-1 15 15 N6-5 t5 C 0 210 (RL) N5-7 V 201 203 M1-33 N5-1 V )Z( C V OM1-35 N6-2C M1-36 ® C M C F N � M1-37 75 F� i ORIENTATION UP V o 15 El S V ITE 15 BREAK OPEN V J CN5-8 �`'1'V V SUITE �CN5-i2 EQUIP DN. OFFICE OFFICE o OFFICE 15 OFFICE 212 WORK V 204 30 220 V Ns-s _ 209 ):( N5-10 C i U -- ------- C 30 i U C N5-11 V tw 00 V 5 M �( N6-7 0 O OFFICE (RL) V V c w N 208 �-- 30 U) Q LN5-9 30 OPEN OFFICE 75 M 30 C ,� N6Cn -10 N6-8 o EOLR 15 V C C Uj OFFICE OFFICE CONFERENCE }� N5-13 EOLR 1N6-11 OFFICE OFFICE 207 206 205 �: DRAWN BY: R. HERMANT C CHECKED BY: J.JOHNSON U) DECC INN INN ISSUE DATE: 1/30/14 J JOB#: PROJECT#: 448:975653601 SIMPLEXGRINNELL© 2013 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN PLAN NORTH N DEVICE PLACEMENT PLAN - 2ND FLOOR w SCALE: 1/8"=1'-0' 0 4 8 12 clij FA-101 X (IN FEET) 0 M END—OF—LINE RESISTOR CODES DEVICE MOUNTING HEIGHTS (PER NFPA 72) Q� NFPA 72 2002 EDITION SUPPLY NFPA 722007 EDITION oN NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS OR RETURN (SECTION A.5.6.3.1) �� T fl- INSTRUCTIONS FOR PROPER TERMINATIONS. 1. MIN DISTANCE IN SLEEPING ROOMS IS 24 (610mm) TO TOP OF LENS DIFFUSER THE 4 REQUIREMENT FOR SMOKE DETECTORS HAS FOR 110CD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 �� * USE WITH RETROFIT OR HIGH CURRENT MODULE 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" REFERENCE (61011 MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3' MIN 4" NOTE: MEASUREMENTS o .. MODEL OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. ( ) (102mm) SHOWN ARE TO THE NUMBER (914mm MIN) CEILING DE�ECTOREDGE OF THE � o �_`� 4081-9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) N.O. INITIATING 4004*, 4004R, 4005*, 4006, HEAT, 4100, 4120, 41000, ZAM S FOR CEILING HEIGHTS LESS THAN 86 2180mm , CEILING MOUNTED PULL, SMOKE, ETC " ( ) NFPA 72 AUDIBLE APPLIANCE SMOKE/HEAT 4 y oo 4081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER, THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6" MIN (152.4mm MIN (102mm) 12 �, 002 24 PT. I 0 SWITCH SUPV. 4605-7401 4100 SERIES ) DETECTOR " (MAX) v. Uc0M / WITHIN 6' (150mm) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING OWE 305mm MAX)CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM EOLR ( � w��' 4081-9003 733-896 4.7K YELLOW VIOLET RED GOLD N/A 1/2 HEAT DETECTORS L3 �rn W 90 MIN 2286mm MIN ou NOTIFICATION DACT 2080-9024 ! ACCEPTED HERE NEVER HERE i �W N.O. INITIATING 4004, 4005, ABOVE FINISHED FLOOR oYUj Uj 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, HEAT, 4090-9001 IDNET IAM T AUDIBLE/VISUAL I I (OTHER MOUNTING HEIGHTS SHALL BE �gCf) WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PTI 0 & VISUAL ONLY PERMITTED BY THE AHJ PROVIDING IT NFPA 72 2010 EDITION 4-20MA ZAM TROUBLE APPLIANCES MEETS THE SOUND LEVEL OUTPUT REQUIRED.) WALL MOUNTED (SECTION 17.7.3.2.1) 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM 96" MAX (NFPA) TO ,EXIT DOOR SMOKE/HEAT (IN LINE) SYNCHRONIZE MORE THAN (2440mm MAX) 5 (MAX.) DETECTOR 4081-9006 733-890 560 n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM TWO APPLIANCES IN ANY ABOVE FINISHED FLOOR (1524mm) 4100, 41000 FIELD OF VIEW. DOOR 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 NFPA 72 2002 EDITION WIDTH (SECTION A.7.5.4.2.5 LESS 3 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008 ) (76mm) 4009, 4010, 4100, 41000 NFPA 72 2007 EDITION 4081-9009 733-912 20n RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 (SECTION A.7.5.4.4.5) SIDE WALL N.C. INITIATING ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM I NFPA 72 2010 EDITION • 4081-9010 733-973 1K BROWN BLACK RED GOLD N/A 1 24 PT. 1/0 (ACROSS CONTACTS) 4605-7401, 4100 SERIES I (SECTION 18.5.4.3.2(4)) MANUAL STATION • / CURRENT LIMITED N.O. INITIATING PULL 4090-9001 IDNET IAM (IN SERIES WITH CONTACT) I 5„ 7 4081-9011 733-974 100BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 80" (ADA) (2032mm) FIRE (127mm) 4081-9012 733-985 22K RED RED ORANGE' GOLD N/A 1/2 SPEAKER CIRCUIT 4003 I REF. 80" MIN (IBC) 80 MIN (NFPA) (2032mm MIN) PHONE MAGNETIC 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1/2 (2032mm MIN) NFPA 72 2002 EDITION JACK DOOR N.C. INITIATING REF. 96" MAX (IBC) (SECTION 7.5.4) HOLDER 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM (2440mm MAX) NFPA 72 2007 EDITION o ® ` FINISHED CURRENT LIMITED N.O. INITIATING ABOVE FINISHED FLOOR (SECTION 7.5.4.1) WALL 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM NFPA 72 2010 EDITION (SECTION 18.5.4.1) 48" MAX (ADA) (1219mm) 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 ! 42" MIN/54" MAX (NFPA) (1067mm MIN/1372mm MAX) 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 ` NOTE: REFER TO THE PROPER DEVICE FINISHED NFPA 72 2002 EDITION 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 ( INSTALLATION INSTRUCTIONS FLOOR (SECTION 5.12.4) 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING EOLR 4100, 41000 FOR BACKBOX MOUNTING HEIGHT. NFPA 72 2007 EDITION NFPA 72 2010 EDITION 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 41000 i (SECTION 5.13.4) (SECTION 17.14.4) 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 41000 TrueAlert7NON—ADDRESSABLE MULrt'I—CANDELA AUDIBLE/VISIBLE NOTIFICATION APPLIANCE TrueAlerf` NON—ADDRESSABLE MULTI—CANDELA VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION FEATURES: (CEILING MOUNT) PRODUCT RES;INFORMATION (CEILING MOUNT) • CLASS B (STYLE Y) OPERATION REQUIRES CONNECTION •UL LISTED TO STANDARD 1971 (ERICO NO. 512) T-BAR TO A COMPATIBLE SMARTSYNC NAC OR TO +I+ •ADA COMPATIBLE WITH CLIPS AND SCREWS SMARTSYNC CONTROL MODULE (SCM) 4905-9938 I SUPPLIED BY CONTRACTOR SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE •SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE HANDY BOY„ 1-1/2" DEEP OR 4905-9938 SCM OR 4100 SERIES FIRE ALARM 4' SQUARE BOX, 1-12" DEEP CONTROL PANEL NAC'S / FOR CLASS B OR CLASS A OPERATION SINGLE GANG BOX, 2-1/2" DEEP OPTIONAL 4905-9928 ADAPTER PLATE. ( •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE SUPPUED BY OTHERS SPECIFICATIONS: REQUIRED FOR SURFACE CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS • HOUSING DIMENSIONS (INCLUDING LENS) : 4-3/4'L X 6-7/8' W X 2-5/8'D MOUNTED ELECTRICAL BOX SINGLE GANG BOX( SPECIFICATIONS: (WIREMOLD V5744S) • TEMPERATURE RANGE 32 F TO 122' F (0 2-1/4" (57mm)C7 2 TO 50' C) •HOUSING DIMENSIONS: 4-3/4' L X 2-5/16' W X 2-5/8' D (121mm X 75mm X 67mm) SUPPLIED BY OTHERS • HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100' F (38' C) o I •TEMPERATURE RANGE: 32'F TO 127F (0 TO 50'C) C_ • TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER OPTIONAL 4905-9915/-9916 ADAPTERIr HUMIDITY RANGE 10% TO 93% NON-CONDENSING AT 100'F (38'C) TERMINAL FOR IN/OUT WIRING. _ 4905-9910 ADAPTER PLATE, •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN OUT WIRING. REQUIRED FOR SURFACE MOUNT IN/ WITH HANDY UNLESS WIRING TERMINALS ARE R THE 4905-9926 WIRE GUARD NG STROBE LOCATED BEHIND HOUSING OPTIONAL 4905-9927 - RATED VOLTAGE RANGE: UL 16 VDC TO 33 VDC PER UL 1971 RED FIRE GUARD WIRING NOTES: O - FLASH RATE: 1 Hz ULC: 20VDC TO 30VDC PER ULC S526-M878 STROBE INTENSITY VIEWING`� 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL O 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. - WIRES UNDER TERMINALS. --------------------------1 Strobe ntensity , 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER-UMITED. viewing slot Uj INTENSITY SELECTION PLUG, 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. n o Intensity selection plug, *CURRENT DRAWS REFLECT STROBE FLASHING AND HORN ON. ACCESSIBLE ONLY FROM REAR OF LENS i , accessible only from rear of lens HOUSING LETTERING RMS CURRENT ® HOUSING, FACTORY SETTING IS 15cd ! y housing;factory setting is 75 cd, MODEL NUMBER COLOR COLOR RATING STROBE: ' -------; - c m m m � �------- -- c m m •RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 m • FLASH RATE: 1 Hz OPTIONAL 4905-9926 WIRE GUARD U) c ULC USTED: 20 VDC TO 30 VDC PER ULC S526-M878 CEILING MOUNT WITH MOUNTING PLATE WHITE RED c 76 mA 57 mA •SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. TO ADDITIONAL NOTIFICATION c m 117 mA 88 mA FROM FACP 24VDC NON-CODED + 25U_rn_T_ 222 MA 17 mA NOTIFICATION APPLIANCE CIRCUIT — — C , c 284 mA 26APPLIANCE DEVICE OR RETURN 3 mA * OR PRECEDING DEVICE, OR SIMPLEX 4905-9914, 9922OR + � � —s TO FACP FOR STYLE Z APPLICATION v � CURRENT DRAWS REFLECT STROBE FLASHING i`— —S IF LAST DEVICE ON CIRCUIT IN A , HOUSING LETTERING RMS CURRENT ® STYLE Y APPLICATION PLACE AN MODEL NUMBER 4 COLOR COLOR RATING 16 VDC 18 VDC 24 VDC 9938 SYNC MODULE. END-OF LINE RESISTOR. (RESISTOR HORN 4906-9102 11c VALUE IS FACP DEPENDENT.) - SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 Hz SWEEP, c m m MODULATED AT 120 Hz RATE _.O - o O 0 - c m 281 mAMA 67 mA 50 mA 0 0 IV— z N c 111 mW A 83 mA ZU) Wti- HORN SOUND OUTPUT RATINGS ® 10 FT. (3m) 1 I c 207 mA 155 mA O 0 � � � __ car+car J car+cKr- c m 281 mA 211 mA VOLTAGE 16 VDC 24 VDC 33 VDC �� z !D 0f SOUND TYPE * STEADY CODED STEADY CODED STEADY CODED I ! O 0 REVERBERATE CHAMBER 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA o 0 J -- - o ! o - - _1 co C UL 464 TEST Q) J-® _ o_ z O O Q ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA - _ =- - — - -- END-OF-LINE FROM FACP 24VDC NOTIFICATION + * CODED VALUES ARE TYPICAL OF THE OUTPUT MEASURED WITH A TEMPORAL APPLIANCE CIRCUIT OR SIMPLEX RESISTOR (VALUE z O C� CODED OR A MARCH TIME CODED PULSE AND WITH A SOUND LEVEL METER 4905-9914, 9922 OR 9938 - is DEPENDENT J READING ON A 'FAST" SETTING. UNDER THE SAME TEST CONDITIONS, CODED SYNC MODULE OR PRECEDING DEVICE ON FACP) 0 C� HORN OUTPUT 'PEAK' SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. a E T N t 3 c 3 0 L h C O M �7 rr Z O�/� - - VJ TZ 1 O M W Q W z Q 4 J U U) W _ U U O W H O ti O It J W O1�d O (n O M r p W H DRAWN BY: R. HERMANT CHECKED BY: J. JOHNSON ISSUE DATE: 1/30/14 JOB#: PROJECT#: 448:975653601 SIMPLEXGRINNELL© 2013 SYSTEM: FIRE ALARM SYSTEM SHEET: WIRING TYPICALS N N W L U_ Q C' X FA-701 M