EQUIPMENT SUBMITTAL
CO Worldwide
Contacts www.tyco-fire.com
Series RFII — 5.6 K-factor
"Royal Flush II" Concealed Pendent Sprinklers
Quick & Standard Response, Standard Coverage
General stallation or finish. The tip of the Pro-
tective Cap can be used to mark the
Description center of the ceiling hole into plaster
p board or ceiling tiles by gently push-
The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- <
"Royal Flush II" Concealed Pendent tective Cap. When ceiling installation
Sprinklers Quick Response (3-mm is complete, the Protective Cap is re- . .:
moved and the Cover Plate/Retainer
bulb) and Standard Response (5-mm 1,.. a.,;;
bulb), are decorative sprinklers featur- Assembly is installed.
ing a flat cover plate designed to con- As an option,the Series RFII Standard
ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II"
optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be
eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal.
ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust . TY3531 (3-mmBulb) is UL Listed,
Seal is intended for sensitive areas C-UL Listed, VdS Approved (Certif-
Each sprinkler includes a Cover Plate/ icate No. G4090007), and NYC Ap-
Retainer Assembly and a Sprinkler/ where it is desirable to prevent air and proved (MEA 353-01-E) as Quick
Support Assembly. separa- dust from the area above the ceiling to
PP Cup Y P Response.
ble, two-piece assembly design pro Pass through the cover plate.
• TY3531 (3-mm Bulb) is FM and
vides the following benefits:
NOTICE LPCB Approved (Ref. No. 094a/10)
• Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response.
and pressure testing of the fire pro- FactoryMutual and LPCB do not
tection systemprior to installation Sprinklers described herein must be
y installed and maintained in compli- approve any concealed sprinklers
of a suspended ceiling or applica- for quick response.
ance with this document and with the
tion of the finish coating to a fixed
applicable standards of the National
ceiling. pp TY3551 (5-mm Bulb) is UL Listed,
Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB
• Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and
ceiling panels for access to building ties having jurisdiction. Failure to do so NYC Approved (MEA 353-01-E) as
service equipment without having may impair the performance of these Standard Response.
to first shut down the fire protection devices.
system and remove sprinklers. Approvals for Air and Dust Seal
The owner is responsible for maintain-
• Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de- UL and C-UL Listed for use with the
vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed
sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551).
length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure
sprinkler drops. with any questions. Maximum 250 psi (17,3 bar) by UL,
The Series RFII Sprinklers are shipped C-UL,and NYC
with a Disposable Protective Cap.The Sprinkler
Protective Cap is temporarily removed p Maximum 175 psi (12,1 bar) by FM,
during installation and replaced to help Identification VdS,and LPCB
protect the sprinkler during ceiling in- Temperature Rating
Number (SIN) 155°F(68°C)Sprinkler with
IMPORTANT TY3531 — 3 mm bulb 139°F(59°C) Plate
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200°F(93°C)Sprinkler with
WARNING" that provides cautions 165°F(74°C) Plate
with respect to handling and instal- Technical Discharge Coefficient
lation of sprinkler systems and corn-
K.5.6 GPM/psi1t2(80,6 LPM/bar1I2)
ponents. Improper handling and in- Data
stallation can permanently damage Adjustment
- a sprinkler system or its components Sprinkler Approvals 1/2 inch(12,7 mm)
and cause the sprinkler to fail to Approvals apply only to the service
operate in a fire situation or cause it conditions indicated in the Design Cri- Finishes
to operate prematurely. teria section. See the Ordering Procedure section.
Page 1 of 4 MARCH 2013 TFP181
TFP181
Page 2 of 4
Physical Characteristics 1/2" NPT SEALING
Frame Bronze , ASSEMBLY
Support Cup Chrome
Plated Steel
Guide Pins Stainless SteelFRAME f', `
Deflector Bronze
Compression Screw Brass {� ; ; / ` V - ` I CAP
;�
Bulb Glass 7!'
Cap Bronze or Copper
Sealing Assembly Beryllium SUPPORT
Nickel w/TEFLON CUP WITH I BULB
Cover Plate Brass ROLL FORMED
Retainer Brass THREADS
Ejection Spring Stainless Steel R
I I COMPRESSION
DesignSCREW
Criteria PINS(2) '%
40 AI
The TYCO Series RFII 5.6 K-factor, DEFLECTOR
"Royal Flush II" Concealed Pendent (DROPPED
Sprinklers are intended for fire protec- DEFLECTOR i c _,._
_-I L J_L__,� POSITION)
tion systems designed in accordance � r j_,...,;_=3__._._.___/'
the standard installation rules rec-
ognized by the applicable Listing or SPRINKLER/SUPPORT CUP
Approval agency;for example, UL List- ASSEMBLY
ing is based on NFPA 13 and VdS Ap-
proval is based on the CEA 4001. THREAD INTO P I RETAINER
FFor more information on LPCB and SUPPORT I I WITH THREAD
ForCUP UNTIL k‘ 0 0 k DIMPLES
VdS Approvals, contact Tyco Fire Pro- MOUNTING
tection Products at the following office: SURFACE IS EJECTION
Enschede,Netherlands FLUSH WITH SPRING
Telephone:31-53-428-4444 CEILING
Fax:31-53-428-3377
The Series RFII Concealed Pendent 1 ..---7--
• Sprinklers are only listed and approved !ter -
with the Series RFII Concealed Cover /
Plates having a factory applied finish. SOLDER J COVER
TABS(3) COVER PLATE/RETAINER PLATE
NOTICE ASSEMBLY
Do not use the Series RFII in applica- FIGURE 1
tions where the air pressure above MODEL RFII CONCEALED SPRINKLER
the ceiling is greater than that be- ASSEMBLY
low. Down drafts through the Sprin-
kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in-
sprinkler operation in a fire situation. sufficient adjustment in the Sprinkler
The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin-
Operation "Royal Flush II" Concealed Pendent kler/Support
the Cup Assembly. Re-adjust
p Sprinklers must be installed in accor- position of the sprinkler fitting to
When exposed to heat from a fire, the dance with this section. suit.
Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the
exposeRetlr at theh Sprinkler/Supporteoints, all aao Do not install any bulb-type sprinkler if of thensprinklert perosition pendicular c lar th the center-line
the
Assembly. Cup the bulb is cracked or there is a loss mounting surface.
of liquid from the bulb. With the sprin-
The Deflector — supported by the kler held horizontally, a small air bub-
- Step 2. Remove the Protective Cap.
Guide Pins — then drops down to its ble should be present. The diameter Step 3. With pipe thread sealant ap-
operational position. of the air bubble is approximately 1/16 plied to the pipe threads, hand-tighten
The glass bulb contains a fluid that ex inch (1,6 mm)for the 155°F(68°C)and the sprinkler into the sprinkler fitting.
pands when exposed to heat. When 3/32 inch(2,4 mm)for the 200°F(93°C) Step 4. Wrench-tighten the sprinkler
the rated temperature is reached, the temperature ratings. using only the RFII Sprinkler Wrench.
(Refer to Figure 3.) Apply the RFII
fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as
glass bulb, activating the sprinkler and should be obtained by applying a min- shown in Figure 3.
allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap
ft.-lbs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms
of torque can distort the sprinkler In- out against the Support Cup. (Refer
let with consequent leakage or impair- to Figure 4.)The Protective Cap helps
ment of the sprinkler. prevent damage to the Deflector and
TFP181
Page 3 of 4
FACE OF CLEARANCE HOLE CLEARANCE
SPRINKLER DIAMETER - HOLE
FITTING DIMENSION C
SPRINKLER J ��
SUPPORT CUP —
ASSEMBLY I l ' '
t
1/2"(12,7 mm) I
D ADJUSTMENT \i „' immi 1/
FACE — —
OF CEILING, y o
RETAINING RING -----•-/ A
MOUNTING / 'I
SURFACE j ,a II /
\ 111 / FIGURE 4
DISPOSABLE PROTECTIVE CAP
I
•—
Arms during ceiling installation and/or
I R
finish. You can also use the Protective
Cap to locate the center of the clear-
3/16"to 11/16" MANUFACTURER DEFLECTOCOVER PLATE clear-
ance hole by gently pushing the ceiling
(4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of
REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY the Protective Cap.
COVER PLATE COVER PLATE NOTICE
PROFILE DEPTH DIAMETER As long as the Protective Cap remains
DIMENSION B DIMENSION A in place, the system is considered
A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service".
B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) Step 6.After the ceiling has been com-
pleted with the 2-1/2 inch(63,5 mm)di-
ameter clearance hole and in prepa-
FIGURE 2 ration for installing the Cover Plate/
SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis-
card the Protective Cap.Verify that the
Deflector moves up and down freely.
If the Sprinkler is damaged and the
Deflector does not move up and down
l=i' - FRAME l _ _� freely, replace the entire Sprinkler.
ARM �% r1 Do not attempt to modify or repair a
pi
— — 1, damaged sprinkler.
SUPPORT �: Step7. Wheninstalling an Air and
s,
CUP I - ' ( Dust Seal, refer to Figure 5; otherwise,
i proceed to Step 8. To attach the Air
I R1I ��������� and Dust Seal, verify the angle of the
I■I ���& A outside edge of the seal is oriented�i ac-
cording to Figure 5. Start the edge of
—— — —— the Retainer in the grooved slot of the
0
7/8"(23 mm) Air and Dust Seal and continue around
- SQUARE the retainer until the entire Air and Dust
Seal is engaged.
// — Step 8. Screw on the Cover Plate/
ALIGN �J ��� Retainer Assembly until the Retainer
FRAME ARMS �1- (shown in Figure 2)or the Air and Dust
Seal (shown in Figure 5) contacts the
1 �i1 r ceiling. Do not continue to screw on
ACCEPTS i i the Cover Plate/Retainer Assembly
\�—��' so that it lifts a ceiling panel out of its
0 1/2"SOCKET normal position. If you cannot engage
DRIVE the Cover Plate/Retainer Assembly
FIGURE 3 with the Support Cup or you cannot
SPRINKLER WRENCH engage the Cover Plate/Retainer As-
RFIIsembly sufficiently to contact the ceil-
ing, you must reposition the Sprinkler
Fitting.
TFP181
Page 4 of 4
Care and SUPPORT SPRINKLER FACE OF ORIENT
Maintenance CUP CEILING SEAL
BEVEL AS
- j=l,____ > SHOWN
The TYCO Series RFII 5.6 K facCOVER
PLATE j� '
tor, "Royal Flush II" Concealed Pen RETAINER -dent Sprinklers must be maintained ASSEMBLY '
and serviced in accordance with this
section.
1& 1
�>Before closing a fire protection system : )
/�main control valve for maintenance
1' �� AIR
work on the fire protection system that ��� AND DUST
1- .... LIP OF COVER
• down the affected fire protection sys- RETAINER PLATE
tern from the proper authorities and FIGURE 5
notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551)
ed by this action.
Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Ordering
Assembly can delay sprinkler opera- reinstall it or a replacement without re-
tion in a fire situation. installing the Cover Plate/Retainer As- Procedure
When properly installed, there is a As-
sembly. If a Cover Plate/Retainer As- YY
nominal 3/32 inch (2,4 mm)air gap be- sembly becomes dislodged during Contact your local distributor for
tween the lip of the Cover Plate and the service,replace it immediately. availability. When placing an order,
ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the full product name.
This air gap is necessary for proper spection, testing, and maintenance of Sprinkler/Support Cup Assembly
operation of the sprinkler. If the ceil- their fire protection system and devic-
op requires the sprininting after. thespr
ler es in compliance with this document, Specify: Series RFII (specify SIN),
ingas well as with the applicable stan- K=5.6, "Royal Flush II" Pendent Sprin-
installation, ensure that the new paint dards of the National Fire Protection klers (specify) temperature rating and
does not seal off any of the air gap. Association(e.g., NFPA 25), in addition (specify)finish, P/N(specify).
Do not pull the Cover Plate relative to to the standards of any other authori-
the Enclosure.Separation may result. ties having jurisdiction.Contact the in- 155°F(68°C) 200°F(93°C)
S rinklers which are found to be leak- stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200
pfacturer regarding any questions. TY3551 51-790-1-155 51-790-1-200
ing or exhibiting visible signs of corro-
. sion must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/
inspected,tested,and maintained by a Retainer Assembly:
Automatic sprinklers must never be qualified Inspection Service in accor-
painted, plated, coated, or other- dance with local requirements and/or Specify: (temperature rating from be-
wise altered after leaving the factory. national code. low) Series RFII Concealed Cover
Modified sprinklers must be replaced. Plate with(finish),P/N(specify).
Sprinklers that have been exposed to 139°F(59°C)(a) 165°F(74°C)(b)
corrosive products of combustion, but Grey White
have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165
if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165
by wiping the sprinkler with a cloth or Pure White(c)
by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165
Care must be exercised to avoid dam- Signal White
(RAL9003) 56-792-4-135 56-792-4-165
age to the sprinklers - before, during, Jet Black
and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165
aged by dropping, striking, wrench Brushed
twist/slippage, or the like, must be re- Chrome 56-792-8-135 56-752-8-165
placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165
- has a cracked bulb or that has lost Custom 56-792-X-135 56-792-X-165
liquid from its bulb. (Ref. Installation (a) For use with 155°F(68°C)sprinklers.
Section.) (b) For use with 200°F(93°C)sprinklers.
Exercise care to avoid damage to (c) Eastern Hemisphere sales only.
sprinklers before, during, and after in- Sprinkler Wrench
stallation. Replace sprinklers damaged Specify: RFII Sprinkler Wrench,
by dropping, striking, wrench twisting, P/N 56-000-1-075.
wrench slipping, or the like. Also, re-
place any sprinkler that has a cracked Air and Dust Seal
bulb or that has lost liquid from its Specify:Air and Dust Seal,
bulb. (Refer to the Installation section.) P/N 56-908-1-001.
GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700
Copyright®2013 Tyco Fire Products,LP. All rights reserved. Vico
TEFLON is trademark of The DuPont Corporation.
Eddythread 40
A Lightweight Schedule 40 Replacement Pipe
That Has a Corrosion Resistance Ratio of 1.0
Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe
products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our
customers have an option to buy a carefully designed replacement for Schedule 40 that:
• Has a Corrosion Resistance Ratio of 1.0
• Has a Pressure Rating of 300 psi
• Is Lighter Weight Than Schedule 40
• Is Approved by Factory Mutual and Listed by Underwriters Laboratories
• Is Produced in Accordance to ASTM A-135 and A-795
• Can be Used With Standard Schedule 40 Threaded Fittings,
Couplings and Valves
• Is Produced From Steel With Excellent Properties of
Strength and Threadability
• Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems*
• Offers Lower Freight Costs
EDDYTHREAD 40 SPECIFICATIONS
• NOMINAL PIPE SIZE(in) WEIGHT(lbs/ft) I.D. (in) BUNDLE SIZE
1 1.461 1.083 70
1 1/4 2.070 1.418 51
1 1/2 2.547 1.654 44
2 3.308 2.123 30
CORROSION RESISTANCE RATIOS
NOMINAL PIPE SIZE(in) SCHEDULE 40 EDDYTHREAD 40
1 1.00 1.00
1 1/4 1.00 1.00
1 1/2 1.00 1.00
2 1.00 1.00
*Eddythread 40 can be hot dippedgalvanized to meet FM's requirement fordrYsystems
Y PP 4
e();t6
1819 Clarkson Road For additional information, C uL us
Chesterfield,MO 63017 contact your salesperson today at O ,
BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED
FAX:(636)537-2645 in the USA,or from Canada
www.bullmoosetube.com call(800)882-4666
A C1010 company e-mail:sales r bullmoosetube.com
APPROVED
All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation.
8/08
4!..1,
�.
; - Ductile Iron Fittings - Class 300 UL/FM
I QuAfirr Puls‘
c01us
APPROVED
LISTED
A Fig. 35E 3- 90°Elbow
• Size A Packing Weight
�r_,.,� Part Number
in in Inner Master lb
___+� 1/2 35E 3004 1.13 100 200 0.2
' 3/4 35E 3006 131 70 140 03
II A 1 35E 3010 1.50 40 80 0.5
�i��, 1-1/4 35E 3012 1.75 25 50 0.8
_ ilk
1-1/2 35E 3014 1.94 18 36 1.1
2 350 3020 . 2.25 10 201.8
2-1/2 35E 3024 2.70 4 8 3.2
Fig. 35RE3-90°Reducing Elbow
1111 B Size A B PackingWeight
E Part Number 9
in in in Inner Master lb`� 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3
I� 1 x 1/2 35RE3010004 1.26, 1.36 70 140 0.4
1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4
n A 1-1/4 X1/2 35RE3012004',; 1.34 153, ' 35. , 70 ,.0.5
1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6
1-1/4 x 1 359E302,410., 1.58 1.67y,. .30 60 *, 0.7
1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6
1-1/2 x 3/4 35RE3014006rr;.; 1.52 1.75. 25, ,,'50 _ 0.7
1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8
1-1/2 X,1-114 3503014012 ' 1.82 1,88 l',..-:18 .. 36 1.0=
2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0
2 X 314 35RE3020006_ , ,1,60 1 97'.,„ ..;..1k..-: :36 n. '..'..1.,P
2 x 1 35RE3020010 1.73 2.02 16 32 1.2
2 x;1-1/4 359.004004, 1.90 ..r.. . ,. 2.10_ .. .,.12. 24 .. .,,,;1,3
D 2 x 1-1/2 35RE3020014 2.02 2 16 10 20 1.5
U _,.
2-1/2 it 1-1/2 35RE3024�i4,_` • 2.16' 2.51 6
12 4 2.2
C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5
T
Fig. 35F 3-45°Elbow
ESize Part NUmher A- - Packing Weight
N A in' ' ins Inner Master •• Ib
,
1/2 35F 3004 0.88 150 300 0,2
3/4 ' 35F 3006 0 J3 80 ,160, 0.3,
4\ 1 35F 3010 1.13 40 80 0.5
1-1/4 35F 30(2 1. 0.i 25 ,;,50 i0.7
l'
�A 1-1/2 35F 3014 1.44 20 40 1.0
•2 .:35F 3020 s.. 1.69. 10 20. 1.6
2-1/2 35F 3024 1.95 4 8 2.7
Fig. 35T 3- Tee
Size A Packing ' Weight
Part Number-
in in Inner ° Master 'ib'
>�'�� A 1/2 351'3004 1.13 80 160 0.3
.11 1911 3/4 351'3006. . . 1.31 30 1 150 0.5
101/ 1 35T 3010 1.50 25 50 0.7
1-1/4 35T 3012 1.75 10 _ ', 20, 1.1
A A 1-1/2 35T 3014 1.94 10 20 15
• 2. 3513020 2.25 6 ' 12 2.4
2-1/2 35T 3024 2.70 4 8 4.3
111 SMITH-COOPER INTERNATIONAL`) • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com
4.i.,
b.
Ductile Iron Fittings - Class 300 UL/FM
Man PLUt
c00us 41>
APPROVED
A
Fig. 35CP3 -Straight Coupling with Ribs LISTED
Size Part Number A Packing Weight
``� in in inner Master Ib
1/2 35CP3004 1.38 200 400 0.1
3/4 35CP3006 1.63 100 200 02
- " 1 35CP3010 1.75 60 120 0.4
1-1/4 35CP3012 2.00 35 70 05
1-1/2 35CP3014 2.19 25 50 0.7
2 35CP3020 2.62 15 30 12
2-1/2 35CP3024 3.00 9 18 2.2
Fig. 35RC3 -Hex Reducing Coupling
111 Size A
art Number Packing Weight
in P
1 x 1/2 in' Inner Master Ib
35RC3010004 1.69
®' A 1 x 3/4 35RC3010006 1.69 80
60 120 0.4
1-1/4 x 3/4 35RC3012006 2.06 40 160
80 0.3
0.6
2 x 1(not hex) 35RC3020010' 2.81 20 40 1.0
Fig. 35HB3 -Hex Bushing
Size A Packing , ' Weight
Part Number
B in in Inner Master lb
? 1 x 1/2 35HB3010004 1.06 180 360 0.2
7711 I
IA 1 x 3/4 35HB3010006 , 1.06 180 - 360 0.1
i 11 1-1/4 x 1 35HB3012010 1.19 90 180 0.2
1-1/2 x 1 35HB3014010 1.25 75 ; 150 0.4
`r s.rt, -..r`7r.f 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3
Q 2 x 1, 35HB3020010,., e1.3$ .. .40 80 0.6
V 2 x 1-1/4 35HB3020012 1.38 40 80 0.6
r- �C 2x.1-1/2 35H83020014
1.38 40 80 0.6
T
Fig. 35SP3 -Square Head Plug
IL
E Size Part Number ` ,' A Packing Weight
in , in Inner Master lb
1/2 35SP3004 0.94 600 1200 0.07
i i A
Ill 3/4 35SP3006 ; 1.12 350 ' 700 0.1
I
1 1 35SP3010 1.25 200 400 0.1
ile , 1-1/4 35SP3012 1.37 100 200 0.3
1-1/2 35SP3014 1.44 80 160 0.4
2 35SP3020 ,' 1.50 45 90 0.6
Fig. 35U 3- Union with Brass Seat
A Size A Packing Weight
Part Number"
t in in Inner Master Ib
1 35U 3010 2.19 20 40 1.0
ifiv
���) 1-1/4 35U 3012 2.50 15 30, 12
1-1/2 35U 3014 2.62 10 20 1.7
70fl°'ac" 2 35U 3020 3.12 6 12 2.4
kago
•
113 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com
Pipe Hangers
Fig. 200- "Trimline"Adjustable Band Hanger (B-Line Fig.B3170NF) ®TOLCo
Fig. 200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) VL
US
Fig. 200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC)
MED
. Fig. 200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut
41>
Size Range:
Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe
Material: Steel, Pre-Galvanized to G90 specifications
Function: For fire sprinkler and other general piping purposes. Knurled --- �v
swivel nut design permits hanger adjustment after installation.
Features: ® __
• • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe moi `,1
types and protect CPVC plastic pipe from abrasion. Captured design ��
keeps adjusting nut from separating with hanger. Hanger is easily g
installed around pipe. A
For hanger with non-captured nut order Fig. 200S.
• (21/2" (65mm)thru 8" (2oomm))Spring tension on nut holds it securely in �_
hanger before installation.Adjusting nut is easily removed.
Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) = Fig.Z00t/z.20a3/4
in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and
Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (2o0mm)). Fig.268-1 to 200-2 Fig.200-21/z to 200-E
Conforms to Federal Specifications WW-H-171 E&A-A-1192A, Type 10
and Manufacturers Standardization Society ANSI/MSS SP-69& SP-58, .s„
Type 10.
Maximum Temperature: 650°F(343°C)
Finish: Pre-Galvanized. Stainless Steel �, y
materials will be supplied with (2) hex nuts `
in place of a knurl nut.
1.
Order By: Figure number and pipe size / „
i ,
Designed to meet or exceed requirements of
FM DS 2-0. `t
g
Fig.200 l•
Fig.200C Fig.200E
Pipe Size Rod Size A B Approx.Wt./100
Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) j
0-0/2
20 1/2" (15) 3/8-16 31/8 (79.4) 25/8" (66.7) 11 (5.0) 71110LN 200-3/4 3/4" 1201 3/8"-16 31/8" 179.41 21/2" (63.5) 11 15.01
200-1 1" (25) 3/e"-16 33/8" (85.7) 25/s" (66.7) 12 (5.5)
. 200-11/4 11/4" 1321 3/8"-16 33/4" (94.0) 21/8" (73.0) 13 15.91
200-13/4 11/2" (40) 3/s"-16 37/8 (98.4) 27/8 (73.0) 14 (6.4) . F
200-2 2" (50) 3/8--16 41/2" (114.3) 3" (76.3) 15 (6.9)
200-2'/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) ±}
200-3 3" (751 3/a"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S
200-31h 31/2' (90) 3/8"-16 73/8 (187.3) 51/4 (133.3) 34 (15.6)
200-4 4" (100) 3/8"-16 13/6" (187.3) 5" (121.0) 35 (16.0)
200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4 (158.7) 66 (30.2)
200-6 6" (1501 1/2"-13 101/8" (257.21 63/4" 1171.41 73 (33.41
200-8 8" (200) W-13 131/e" (333.4) 83/4" (222.2) 136 (62.3)
All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. -Line
Fire Protection Solutions 21 V
by E.T•N
Threaded Accessories
B3205 - Threaded Rod (right-hand threads - both ends) (Tosco Fig.103)
• B3205L -Threaded Rod (right&left hand threads) f n 1110
Size Range: 3/8"-16 thru 3"-4 rod Specify Length \11\\l��\l\
• Material: Steel
Function: Recommended for use as a hanger support in hanger assemblies. n
on� Dohasd tsIso �\ 1
\
A
aailable d is withft and right hand threadsPecfy Fig. B3205L of the wen ordering. �
Thread Size
Maximum Temperature:
°
u 750 F(399°C)
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Part number,rod size,length and finish
Standard Design Load
Thread Size Thread Length TL 650°F(343°C) 750°F(399°C)
Part No. A in. (mm) Lbs. (kN) Lbs. (kN)
83205-3/8x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54)
83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70)
133205-5/8 x'1.' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52)
133205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25)
B3205.7/8x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60)
B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55)
B3205-11/8X'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93)
B3205-11/4 x112 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09)
113205-11/2 x11.1 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07)
83206-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79)
83205-2x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29)
B3205-21/4x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51)
B3205-21/2 x11.' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64)
B3205-23/4 x11.' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08)
- 83205-3 x112 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35)
ATR -All Threaded Rod 120" (3.05m)Lengths (TOLCO Fig.100)
Fig. 99-All Threaded Rod Cut To Length
1111 „�111`��''
Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length ���l��llll`�»1����
Material: Steel J •)!*� v m
Maximum Temperature: 750°F(399°C) v `o
RI Finish: Plain. Contact B-Line for alternative finishes and materials. ' m
Order By: Part number,rod diameter and finish Q
- Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft.
ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg)
AIR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44)
ATR 3/h"x 120 99-3/e"x length 16 730 (3.24) 29 (13.15)
ATR 1/2".x 120 99-1/2'x length 13 1350 (6.00) 53 (24.04)
ATR 5/e x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37)
ATR 14"X 120 '' /4"x length 10 3230 (14.37) 123 (55.79)
ATR h"x 120 99-7/a",x length 9 4480 (19.93) 170 (77.11)
ATR 1"x 120 99.1"x length 8 5900 (26.24) 225 (102.06)
All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. R
ine
Pipe Hangers&Supports 236 Revised 4/28/2014 by E T.N
by L
SAMMY X-PRESS® SAMMYS
Sammy X Press°
PFeures
•Theroduct Sammy atX-Press expands to provide •Installs in seconds,saving time&
(XP) lir direct vertical attachment in: installation costs.
,°; ° Patent N°. • Metal Deck(22-16 gauge)
8,935,821 —' , i._y
i -Z-Purlin(18-16 gauge) •Use in applications where access
to the back of the installed fastener is
II
•Ttohe Sammy
hangplumbiXPressextreme Swivelroofallowsoprohibited.ie.metal roof dek,tubular
n pitches:
u
steel,or vapor barrier fabric.c
(SWXP) -89°in Z-Purlin
-45°in metal deck for 12/12 pitch •Less jobsite material needed.
Patenl •
Pending
for •The Sammy X-Press Sidewinder expands •No retaining nut required.
(S�) extreme to provide horizontal attachment in:
-16 ga-3/16°steel-purlin,tubular •Provides design flexibility.
or
steel.
Patent Pending Variant
roof Pitches
Approvals Rod Part Model Description
Ultimate UL Test FM Test Min Max Box Case" ,PBcalfon
Size Number Pullout(lbs) Load(lbs) Load(lbs) Thick Thick Qty_WYQty
• 1/4' 8181922 XP 200 X-Press 200 1146(22 ga) 185(Luminaire)
250(Luminaire) .027'
.056' 125' 25 125 Metal Deck
850(234 Pipe) 940(7 Pipe) .027
185(Luminake)
• JP318' 8150922: XP 20 X Press 20 1146(22 pa) 1475(4'Pipe) .027',; .125'
. 25 125 Metal Deck
250(Llmhaire) 056"
283(Condut&Cable) 056
•
1500(4'Pipe) .060'
•
til." , 3/8' 8153922 XP 35 X-Press 35 1783(16 ga) 85(Luminaire) 940 (2'Pipe) 105' .125' 25 125 Purlin
250(Luminaire) 1475(4'PO) .027'
416(Conduit&Cable) .056'
750(7 Pipe) : , r
1061 in ga Vertical) 170 verticil(Lumineke)
Q 3/8' 8294922 SXP 20 Swirl X-Press 20 829(45•C8 Yedice- ,80 45 (Luminaire) -635(7 Pipe) . .027'x. .125' 25 125 Metal Deck
' ` 233045•(Conduk&Cable) °
1500(4'Pipe)
<a> 1675(16gaVert•cal)2250 rtic(I(Luminaij) ( P
318' 8295922 SXP 35 Swivel X-Press 35 1558(89'Off Vertical) 80 90' Luminaire 635 2 Pipe) .060' .125' 25 125 Purlin
500 vertical(Conduit&Cable)
333 Q 89•(Conduit&Cable)
. Pre-Pwr Structural Concrete/3000 peiMetal Deck
— , Q.• 3/8' 8150922' XP 20 SemmyX-Press 20 1146(22 pa) k"' 850(2)S Pte) 't • ,_ 25 125 :' 0're-Pwr)
'- , , It'
-':Poet-Pair Rungs►1 LYVCs 35 PCF(lbdR') Metal Deck
HGR'ZOr',--,%.' INT
1250(3'A"Pipe)
a 3/8' 8293957 SWXP 35 Sidewinder X-Press 35 1798(16 ga) 80(Luminaire) .060' .125' 25 125 Pu din
416(Conduit&Cable)
Pre-Pour Structural Concrete*3000 psi Post-Pour Range II LWCS 35 PCF gbsi k')
--/—‘--r‘— —rki!r\— '"' ' 4 ,wrici,,wayi.,I
Sammy X Press It° INSTALLATION TOOL
,
Yw +
UXPIT r 'f 1 + :.
.ie
Patent Pending �` T')a 'a
Part Number Model Description Each Qty `,, a
8194910 UXPIT•; UnipersalX-PressltTool 1 ► )
8195910 RXPIT Retro Socket for 8151910 1 t` --
8152910 ?0'Oe 25164•DrMBit 1 To watch a video demonstration of the SammyX-Press,visit httpl/Wwwsammysuperscrew.corn'ammyxpress.htm
'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64'Drill Bit. ®f
For the most up to date information visit www sammyseperscrew corn 8 9 \�/ eU