Report (49) 1 c,06-&J 7c1-10 S60 cf)G. SA. <-SC . /5‘---15". 'Carries RECEIVED SEP 2 9 2015 or United Technologies CITY OF TIGARD BUILDING DIVISION SUBMITTAL Project See's Candies Washington Square Submitted To Grey Wolf HVAC Date Monday, September 28, 2015 Submitted By Airefco, Inc. 18755 SW Teton Ave Tualatin OR 97062 (503)692-3210 RTU-1 Project:See's Candies—Washington Square 09/28/201E Prepared By:Airefco, Inc. 11:31 AN RTU-1 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.39s Page 2 of 7 I Unit Report For RTU-1 Project:See's Candies—Washington Square 09/28/201E Prepared By:Airefco, Inc. 11:31 AN, Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model. 50VT-B30---3 Unit Length. 4'0.1875" Unit Size. 30(2-1/2 Tons) Unit Width. 2'8.625" Volts-Phase-Hertz. 208-1-60 Unit Height: 3'8.125" Heating Type. Heat Pump *** Weights and Dimensions are approximateWeight does not include roof Duct Cfg: Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Total Operating Weight. 346 lb Warranty Information 1 year warranty on parts 5 yearwarranty on compressor No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50VT-B30---3 Rooftop Unit 1 Base Unit Accessories CPHEATER052A00 3.8/5.0 kW,208/230-1-60 volt, Electric Heater 1 CPHSTART002A00 Compressor Hard Start Kit 1 MM SPP09-SML-ADBVEC Vertical D/B Economizer 1 MM SPP09-HPRLYKIT01 H/P Relay Kit 1 MM CRB-SDSML-14 14"K.D. Roof Curb—Non-Calculated 1 Packaged Rooftop Builder 1.39s Page 3 of 7 Certified Drawing for RTU-1 Project:See's Candies-Washington Square 09/28/201 Prepared By:Airefco, Inc. 11:31 AN, 311 SHIES EL11101CAL OBIT IT. UNIT EIWFT Dor CERT'OF 6104115 1110. CEI/ACTEOISTIS LI W 'A' 1 ' 7 SOOT-071--- 1 703(233-' 313 Ile a-UI '121 (3-1/2 52' 15117 31A 30-f I? 1110 5]37-830--- 1 7001730-1. 736/230-3-50 310 151 /1-118 'III 71.112 52' 15.1/7 3104 IF-117 110 LI/14 01171 *011011 CORKER KKR .7. .3. .1. 5001-1024---7011233 53 47 15 33' 30 31 IC? li 5001-050---20101130 30 4' TI 3? 19 50 100 43 1-•6141 1'-'111-- 1-17.11" NOTE ILL CARLE DATA RELEIA11 FOR ILL 54[10(21 1111311E1 125/41 [Sn. 7 832.11 SP/0045 EICEFT 11011041141 I-1531 III 31 i 1111- ............10 .OL -711 �WMlik. INPLf INCHES 1,111o7f 71- ❑ 711 I01 OF 01 0 . ,. .... '1 0353 LI [OCT 0150 Oi Mft.. 2 ISO 31 ___��� ' 00010 00SITF INCTS... - - 11(313.11 1 ILICIO OF 14510 _.. A 10 O1 trim . 404 I6 f 1L' 3M1Lif*Moot 1 FLFCTIICAL PI<L. 31[571.1] [101.17 0 , OPfI[R �,' df4IM e� ..... INCHES[MMT OETMEER UMTS 50130 30111 DIE 12 13(11 11 P 1'� : - 1 « 411T IID 316033503(SIIFKES,rou 3110'SIDE S{(011.01 --- -� 11111 IIP 5LOC1 OI COIC5311 MLLS 110 31RE0 (1031033 53551[[3,MIP EwTRT SINN 11[1055.11 030001 CDEL-i,. ;.`----Ti OMAN N R11 U' NC [5(11[5[MI5 IL ...74,„?.,..., -a: -- f. 1410.COR ACCESS SID 01 1114.11 �- iii10101[0110 SIDE 17 11055.00 ID III .3 1'CE'?100 NEC 105071 401101. 0511 101 03 11711.23 10001 wn 1000,COIL SIN OPPOSITE DUCTS.... 35 1911.01 W 010[7•I/EL . . .. ....,. 17[JB1 III TCP NE •111001$(STAOCES:IF MT IS PLACED LESS TRAP 17 1141.41 100*ALL S'S1EM.TIIER 3351110/R7CRMMtt RALE COWPOIISEO. f1!16 * DIRE111011 II[1 ARE(I RILL0ETE11 IM2.77 Of A1 1 ..---_---__ (N-I1 31.91 ti IIIIIIIIII t .. f. . ,.. !IIIIIIII1111! I_hIHiIflhIIIHIIihh' IIIIIIIIIIIIIIIIIIII +:IIIIIIIIIIIIIIIIII • s '-J11 111 51 7V.A.O. 1 d FIT{r IRWII flan1!-r.I05(7030050*6 } 11111 (03.7] OrP115i I 1�7� 114.7]1-511t7-'7116 go" Imraml,/O37.11y'l., - I.' �1 '1 I US II f ML- � 1-f.7 E\ - O ��� IE i6� O [160.1 f�� MM /pop OUTLET-'� 1-15•!0 •1•---- , 47411, .1-7376 I [el13(I 1117 0 0 3 011*! �3a.17 f3M•rF160r -viz _ [11.31 b![77.t1 0[I.x011 7-'531 -tLfcntoL [al 51 N-3!•1 1CC1(0.15CL /-13.16 (OEM Mir 1-711 71-511 1-150 37-0'1 1322 27 [750.12 151.31 1103.111 1470 11 1.271 01 REAR YEW LIFT SCE VIEW RENT VIEW MOST SCE VEY aI 5O'2T50C37C _ ' Packaged Rooftop Builder 1.39s Page 4 of 7 SUBMITTAL MicroMetl Down Discharge Economizer with Filter Rack Part Number: - for Carrier 48/50ES,EZ,VL 024-036,A24-A36; FORM NO. 7859_1p DATE: 6/09 48/50VT 024-030,A24-A30; ECD-SDSML=* SUBMITTED TO: 50GL,JZ 024-036,A24-A36 Units COMPANY: Features: Carrier Equivalent: CPECOMZR007A00 1 DRAWN BY:T. HUBBARD • Economizer for down application only. JOB NAME: • Fully assembled,easy to install. EQUIPMENT: •2"Filter rack and 1"TAW filters provided. FILTER RACK SIZE NOTES: • Rainhood ships assembled, includes a water 1"Filters (2) 12"x 20"x 1" entrainment filter and is constructed of prepaint steel. (1) 10"x 20"x 2" Econo. Part No. Controls •Low leak outside air damper. 2"Filters (1) 12"x 20"x 2" ECD-SDSML-ADB-CD Dry Bulb • Barometric relief damper. ECD-SDSML-ENT-CD Enthalpy NOTES: ECD-SDSML-NC-CD No Controls 1. Relays required for heat pump units can be field supplied or order Carrier Kit CPRLYKIT001A00. 2. Economizer should not be used on XL,XT INFINITY units. Supply air cover 3. Economizer includes harness extensional for older units panel. Shipped on with no economizer harness factory installed. HVAC unit. 4. The"NC"economizer models do not include actuator, controller, sensors, or wiring harness. 4 f ii,,..,...% % IIIIIII �.--_ Coif — IIIIII i IIIIII °° , . IIIIII IIIIII °° , Filters provided IIIIII IIIIII ® Replacement panel °° IIIIII shipped with ,.� •00041 IIIIII economizer some °O IIIIII IIIII0111111111111111111111111 newer units will 00 161,,,si include this panel) 00 \\\ 00 00 °° ® 00 Panel for °O filter and 'll0 °° ;•... I \N Aluminum water controls access °° entrainment � � � filter ��1'$ ,/ Economizer `� ji ��/ outside air %���/I damper Economizer's jj%�� Rainhood with SIDE VIEW relief /� water entrainment Down Discharge damper filter THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT MICROMETL CORP.-3035 NORTH SHADELAND AVENUE,SUITE 300-INDIANAPOLIS,IN 46226-1-800-662-4822-MICROMETL SPARKS-905 SOUTHERN WAY-SPARKS,NV 89431-1-800-884-4662 SUBMITTAL MiC1 oMetI Part Number: CRB-SDSML-14 FORM NO. 7843-1D I 7/21/2014 Submitted To: Company: 10" 111414410. Job Name: Notes: 21 9/1." .4 .°101/011/. Knockdown Curbs NA.,...„ 16 Full Perimeter 2r>g„ 10" �► )74? NOTES: • *Custom Heights Are Available. 14%.:4111111111111Stp" 110. • *Fully Insulated Peruneter Curbs Are Available And Designated With A"CI"Suffix. A • *Hold Down Brackets Are Available For Most Curbs. • Attach Ductwork Directly To Roof Curb.Flanges Of Duct w 4411114444 Rest On Top Of Curb. • Any Posted Weight Is Actual Weight,Not Shipping Weight 6 • All Dividers&Supports If Present,Are Flush With Top Of 26,, IIab, Curb Unless Noted. 4 /O w Please Contact Factory For Pricing and Availability FEATURES: I1" I -f— p 2.75" • Ships Knockdown,Assembly Hardware Provided When �� Needed. : • Deck Pans When Factory Provided,Are Factory Insulated. i___ • Constructed Of Galvanized Steel. .875" • Gasketing Package Provided. MicroMetl Curb No. Carrier Curb No. A Weight • Full Perimeter Wood Nailer Provided. CRB-SDSML-08 -8" 56 lbs 2" CRB-SDSML-11 CPRFCURB010A00 11" 63 lbs CRB-SDSML-14 CPRFCURB011A00 14" 70 lbs CRB-SDSML-18 18" 91 lbs CRB-SDSML-24 24" 108 lbs CU-2D THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada— 1-800-884-4662, Longview Texas— 1-903-248-4800 Performance Summary For RTU-1 Project:See's Candies-Washington Square 09/28/201E. Prepared By:Airefco, Inc. 11:31 Alv Part Number:50VT-B30---3 ARI SEER• 14.20 Application EER(Rooftop Unit only) 11.96 Base Unit Dimensions Unit Length• 48.2 in Unit Width: 32.6 in Unit Height: 44.1 in Total Operating Weight 346 lb Unit Unit Voltage-Phase-Hertz: 208-1-60 Air Discharge. Vertical Fan Drive Type• Direct Actual Airflow: 939 CFM Site Altitude* 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB• 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/Ib Evaporator Leaving Air DB• 59.0 F Evaporator Leaving Air WB• 57.5 F Evaporator Leaving Air Enthalpy. 24.74 BTU/lb Unit Discharge Air DB: 59.0 F Unit Discharge Air WB: 57.5 F Unit Discharge Air Enthalpy: 24.74 BTU/lb Net Cooling Capacity: 28.29 MBH Net Sensible Capacity. 21.27 MBH Total Unit Power Input. 2.37 kW Coil Bypass Factor. 0.035 Heating Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB: 70.0 F Leaving Air Indoor Coil DB• 99.3 F Total Heating Capacity. 29.74 MBH Integrated Heating Capacity. 29.74 MBH Heating Power Input. 2.47 kW High Temperature COP: 3.5 Low Temperature COP: 2.1 HSPF: 8.0 Electric Heating Capacity: 3.80 kW Unit Leaving Air Temp• 112.1 F Supply Fan External Static Pressure. 0.40 in wg Options/Accessories Static Pressure Economiser 0.09 in wg Wet Coil: 0.05 in wg Total Application Static(ESP+Unit Opts/Acc.): 0.54 in wg Fan Power 0.32 BHP • Fan Motor Size, hp. 1/2 NOTE: High Motor Speed,Vert Electrical Data Minimum Voltage: 187 Maximum Voltage: 253 Packaged Rooftop Builder 1.39s Page 5 of 7 Performance Summary For RTU-1 Project:See's Candies-Washington Square 09/28/2015 Prepared By:Airefco, Inc. 11:31 AN Compressor RLA• 14.1 Compressor LRA• 73 Actual Electric Heater kW: 3.8 Electric Heater FLA• 18.1 Outdoor Fan FLA(ea): 1.2 Indoor Fan Motor FLA: 4.1 Power Supply MCA: 45.6 Power Supply MOCP, Fuse or HACR, U.S.A• 50 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating: 75.0 db Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 63.5 250 Hz NA NA 66.0 500 Hz NA NA 71.0 1000 Hz NA NA 69.5 2000 Hz NA NA 66.5 4000 Hz NA NA 61.0 8000 Hz NA NA 54.0 Advanced Acoustics 441 Si (c 0 o Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver. 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 _125.250.500 1k 2k 4k 8k Overall A 0.0 _63.5 66.0 71.0 69.5 66.5 61.0 54.0 75.3 Lw • B -26. 47.4 57.4 67.8 69.5 67.7 62.0 52.9 73.7 LwA 2 C 0.0 31.1 33.6 38.6 37.1 34.1 28.6 21.6 42.9 Lp D -26. 15.0 25.0 35.4 37.1 35.3 29.6 20.5 41.3 LpA 2 Packaged Rooftop Builder 1.39s Page 6 of 7 Performance Summary For RTU-1 Project:See's Candies—Washington Square 091281201E Prepared By:Airefco, Inc. 11:31AN Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.39s Page 7 of 7