Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
fpRoc- 000,4 1"-v sA' (2 -sit S�RECEIVED FEB 262015 .� CITYOFTIGAflU g3 , vv YAT irLDINGDIVISION e°��+Y i� " °-,,,t4 AFIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 MICHAEL KORS 9620 SW WASHINGTON SQ RD W100 TIGARD, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL .. t ,cii Worldwide www.tyco-fire.corn Contacts Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers - Quick & Standard Response, Standard Coverage General stallation or finish. The tip of the Pro- tective Cap can be used to mark the Description center of the ceiling hole into plaster I" board or ceiling tiles by gently push- The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- "Royal Flush II" Concealed Pendent tective Cap. When ceiling installation Sprinklers Quick Response (3-mm is complete, the Protective Cap is re- bulb) and Standard Response (5-mm moved and the Cover Plate/Retainer bulb), are decorative sprinklers featur- Assembly is installed. ing a flat cover plate designed to con- As an option,the Series RFII Standard ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal. • TY35313 mm Bulb) is UL Listed, ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust ( includes a Cover Plate/ Seal is intended for sensitive areas Each sprinklerCUL Listed, VdS Approved (Certif where it is desirable to prevent air and icate No. G4090007), and NYC Ap- Retainer Assembly and a Sprinkler/ dust from the area abovthe ceilingto proved (MEA 353-01-E) as Quick Support Cup Assembly. The separa- through the cover plate. Response. ble, two-piece assembly design pro- passg vides the following benefits: • TY3531 (3-mm Bulb) is FM and NOTICE LPCB Approved (Ref. No. 094a/10) • Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response. and pressure testing of the fire pro- Sprinklers described herein must be Factory Mutual and LPCB do not Lection system prior to installation installed and maintained in comp/i approve any concealed sprinklers of a suspended ceiling or applica- forquick response. tion of the finish coating to a fixed ance with this document and with the ceiling. applicable standards of the National • TY3551 (5-mm Bulb) is UL Listed, Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and ceiling panels for access to building ties having jurisdiction.Failure to do so NYC Approved (MEA 353-01-E) as service equipment without having may impair the performance of these Standard Response. to first shut down the fire protection devices. system and remove sprinklers. Approvals for Air and Dust Seal The owner is responsible for maintain- • Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de UL and C-UL Listed for use with the vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551). length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure sprinkler drops. with any questions. Maximum 250 psi (17,3 bar) by UL, The Series RFII Sprinklers are shipped C-UL,and NYC with a Disposable Protective Cap.The Sprinkler Maximum 175psi (12,1 bar) byFM, Protective Cap is temporarily removed during installation and replaced to help Identification VdS,and LPCB protect the sprinkler during ceiling in- Temperature Rating Number (SIN) IMPORTANT 155`F(68'C)Sprinkler with Always refer to Technical Data TY3531 — 3 mm bulb 139`F(59°C) Plate Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200°F(93'C)Sprinkler with WARNING" that provides cautions 165°F(74°C) Plate with respect to handling and instal- Technical Discharge Coefficient lation of sprinkler systems and cornK=5.6 GPM/psivz(80,6 LPM/bar1i2) - ponents. Improper handling and in- Data stallation can permanently damage Adjustment a sprinkler system or its components Sprinkler Approvals 1/2 inch(12,7 mm) and cause the sprinkler to fail to Approvals apply only to the service operate in a fire situation or cause it conditions indicated in the Design Cri- Finishes to operate prematurely. teria section. See the Ordering Procedure section. Page 1 of 4 MARCH 2013 TFP181 TFP181 Page 2 of 4 J Physical Characteristics 1/2, NPT %, SEALING �' Frame Bronze ASSEMBLY Support Cup Chrome Plated Steel Guide Pins Stainless Steel FRAME r / \ Deflector Bronze � Compression Screw Brass CAP Bulb Glass °�-� .--� Cap Bronze or Copper SUPPORT Sealing Assembly Beryllium CUP WITH Nickel w/TEFLON BULB ROLL FORMED Cover Plate Brass THREADS Retainer Brass _ Ejection Spring Stainless Steel I I COMPRESSION Design SCREW esu n GUIDE Criteria PINS(2) 1 / .ffillr• I- The TYCO Series RFII 5.6 K-factor, DEFLECTOR "Royal Flush II" Concealed Pendent - — (DROPPED Sprinklers are intended for fire protec- DEFLECTOR c L ]/_ POSITION) tion systems designed in accordance r _r with the standard installation rules rec- ognized by the applicable Listing or SPRINKLER/SUPPORT CUP Approval agency;for example,UL List- ASSEMBLY ing is based on NFPA 13 and VdS Ap- i I proval is based on the CEA 4001. THREAD INTO I RETAINER SUPPORT WITH THREAD For more information on LPCB and CUP UNTIL is O Q DIMPLES VdS Approvals,contact Tyco Fire Pro- MOUNTING tection Products at the following office: SURFACE IS EJECTION Enschede, Netherlands FLUSH WITH SPRING - Telephone:31-53-428-4444 CEILING Fax:31-53-428-3377 The Series RFII Concealed Pendentr-i t_.,. .. --- Sprinklers are only listed and approved /—r with the Series RFII Concealed Cover Plates having a factory applied finish. SOLDER -' COVER TABS(3) COVER PLATE/RETAINER PLATE NOTICE ASSEMBLY Do not use the Series RFII in applica- FIGURE 1 tions where the air pressure above MODEL RFII CONCEALED SPRINKLER the ceiling is greater than that be- ASSEMBLY low. Down drafts through the Sprin- kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in- sprinkler operation in a fire situation. sufficient adjustment in the Sprinkler The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- Operation "Royal Flush II" Concealed Pendent kler/Support Cup Assembly.Re-adjust N Sprinklers must be installed in accor- the position of the sprinkler fitting to When exposed to heat from a fire, the dance with this section. suit. Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the Retainer at three points, falls away to Do not install any bulb-type sprinkler if pendent position with the center-line expose the Sprinkler/Support Cup of the sprinkler perpendicular to the Assembly. the bulb is cracked or there is a loss mounting surface. of liquid from the bulb.With the sprin- Step2.Remove the Protective The Deflector — supported by the kler held horizontally, a small air bub- Cap. Guide Pins — then drops down to its ble should be present. The diameter Step 3. With pipe thread sealant ap- operational position. of the air bubble is approximately 1/16 plied to the pipe threads, hand-tighten The glass bulb contains a fluid that ex- inch (1,6 mm)for the 155°F(68°C)and the sprinkler into the sprinkler fitting. pands when exposed to heat. When 3/32 inch(2,4 mm)for the 200°F(93°C) Step 4. Wrench-tighten the sprinkler temperature the rated temperature is reached, the ratings. using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as glass bulb,activating the sprinkler and should be obtained by applying a min- shown in Figure 3. allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap ft:lbs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms of torque can distort the sprinkler In- out against the Support Cup. (Refer let with consequent leakage or impair- to Figure 4.)The Protective Cap helps ment of the sprinkler. prevent damage to the Deflector and TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER - DIAMETER -- HOLE FITTING DIMENSION C J i=i' SPRINKLER SUPPORT CUP —`` .? . .y - ASSEMBLY 1/2'(12.7 mm) i D ADJUSTMTHREADEENT��\ tll — „11141 �i FACE I•I--- OF CEILING. RETAINING RING17,,,i MOUNTING // 1 7 i SURFACE4 i I \ \ I If FIGURE 4 r s DISPOSABLE PROTECTIVE CAP I H Arms during ceiling installation and/or =z r_ J _ / finish.You can also use the Protective i \ T i-r 'V Cap to locate the center of the clear- 3/16”to 11/16" MANUFACTURER DEFLECTOR COVER PLATE ance hole by gently pushing the ceiling (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of REFERENCE 3/32"(2.4 mm) POSITION ASSEMBLY the Protective Cap. COVER PLATE COVER PLATE NOTICE -PROFILE DEPTH - DIAMETER - As long as the Protective Cap remains DIMENSION B DIMENSION A in place, the system is considered A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service". Step 6.After the ceiling has been com- B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) pleted with the 2-1/2 inch(63,5 mm)di- ameter clearance hole and in prepa- FIGURE 2 ration for installing the Cover Plate/ SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis- card the Protective Cap.Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the —, � Deflector does not move up and down X11=1� FRAME jl=/,__ ARM ;"// freely, replace the entire Sprinkler. 1 Do not attempt to modify or repair a - 1 damaged sprinkler. 1 SUPPORT ( Jill �( Step 7. When installing an Air and i CUP I Dust Seal, refer to Figure 5;otherwise, T proceed to Step 8. To attach the AirIBM , and Dust Seal, verify the angle of the���"��A outside edge of the seal is oriented ac- ' Icording to Figure 5. Start the edge of --------- the Retainer in the grooved slot of the , 4117,'8"(23 mm) 0 Air and Dust Seal and continue around SQUARE the retainer until the entire Air and Dust / Seal is engaged. —` Step 8. Screw on the Cover Plate/ ALIGN \ Retainer Assembly until the Retainer ARROWS WITH 1 \ (shown in Figure 2)or the Air and Dust FRAME ARMS — Seal (shown in Figure 5) contacts the `}� ceiling. Do not continue to screw on 1 i the Cover Plate/Retainer Assembly ACCEPTS —r �' so that it lifts a ceiling panel out of its 0 1/2"SOCKET \\ normal position. If you cannot engage - DRIVE the Cover Plate/Retainer Assembly FIGURE 3 with the Support Cup or you cannot SPRINKLER WRENCH engage the Cover Plate/Retainer As- RFIIsembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Care and SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING - `� SEAL Maintenance BEVEL AS 'j�<1/4___ \,• SHOWN The TYCO Series RFII 5.6 K-fac- uI1lIi1i 1 COVER tor, "Royal Flush II" Concealed Pen- PLATE dent Sprinklers must be maintained RETAINER - and serviced in accordance with this )) ;�� ASSEMBLY section. / • Before closing a fire protection system c( -------/.�....sS\ main control valve for maintenance 1 N��1W ` �-, AIR work on the fire protection system that / � ���� �%'IIi. /�="/ AND DUST _ it controls, obtain permission to shut .-_--�- • .= SEAL ___ — ------- �� LIP OF COVER down the affected fire protection sys- RETAINER PLATE tern from the proper authorities and FIGURE 5 notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII TY3551 ed by this action. ( ) Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Assembly can delay sprinkler opera- reinstall it or a replacement without re- tion Ordering in a fire situation, installing the Cover Plate/Retainer As- When properly installed, there is a sembly. If a Cover Plate/Retainer As- Procedure nominal 3/32 inchbe- sembly becomes dislodged during (2,4 mm)air gap nt Co act your local distributor tween the lipof the Cover Plate and the service,replace it immediately. for availability. When placing an order, ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the fullp roduct name. This air gap is necessary for proper spection, testing, and maintenance of Sprinkler/Support their fire protection system and devic Cup Assembly operation of the sprinkler. If the ceil- es in compliance with this document, Specify: Series RFII (specify ing requires repainting after sprinkler p Y ( p Y SIN), installation, ensure that the new paint as well as with the applicable stan- K=5.6, "Royal Flush II" Pendent Sprin- does not sealn, a suany the air gap. dards of the National Fire Protection klers (specify) temperature rating and Association(e.g., NFPA 25), in addition (specify)finish, P/N(specify). Do not pull the Cover Plate relative to to the standards of any other authori- - the Enclosure.Separation may result. ties having jurisdiction.Contact the in- 155°F(68'e) 200`F(93°C) Sprinklers which are found to be leak- stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200 ing or exhibiting visible signs of corro- facturer regarding any questions. TY3551 51-790-1-155 51-790-1-200 sion must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/ Automatic sprinklers must never be inspected,tested,and maintained by a Retainer Assembly: utomaqualified Inspection Service in accor- painted, plated, coated, or other- dance with local requirements and/or Specify: (temperature rating from be- wise altered after leaving the factory. national code. low) Series RFII Concealed Cover Modified sprinklers must be replaced. Plate with(finish), P/N(specify). Sprinklers that have been exposed to 139'F(59°c)(a) 165°F(74 C)(b) corrosive products of combustion,but Grey White have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165 if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165 by wiping the sprinkler with a cloth or Pure White(c) by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165 Signal White Care must be exercised to avoid dam- (RAL9003)., 56-792-4-135 56-792-4-165 age to the sprinklers - before, during, Jet Black and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165 aged by dropping, striking, wrench Brushed twist/slippage, or the like, must be re- Chrome 56-792-8-135 56-792-8-165 placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165 has a cracked bulb or that has lost Custom 56-792-X-135 56-792-X-165 liquid from its bulb. (Ref. Installation (a) For use with 155 F(68 C)sprinklers. . Section.) (b) For use with 200'F(93'C)sprinklers. (c) Eastern Hemisphere sales only. Exercise care to avoid damage to sprinklers before, during, and after in- Sprinkler Wrench stallation.Replace sprinklers damaged Specify:RFII Sprinkler Wrench, by dropping, striking, wrench twisting, P/N 56-000-1-075. wrench slipping, or the like. Also, re- place any sprinkler that has a cracked Air and Dust Seal • bulb or that has lost liquid from its bulb.(Refer to the Installation section.) Specify:Air and Dust Seal, P/N 56-908-1-001. GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright®2013 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. Dyna-Thread® - M-COAT® Submittal Data Sheet Fuii Line Scil-40 Replacement Dyna-Thread—M-COAT Specifications — ; i-11 NPS Nominal LD. Wt. Wt.(H20 Filled) CRR CRR 5, In; pin,--H; In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded Threaded 1" 1.080 1.330 1.75 11.39 1.00 : 25 27.4 2.0 2.60 — -;; 11/4" 1.408 1.870 2.54 9.50 1 00 IT.CFrp?,fiSCil to S '1..11' 40 32 35.8 2.8 3.78 11/2" 1.639 2.290 3.22 9.14 1.00 E.i,€ 0, IOH FC.FIJ 40 41.6 3.4 4.79 L:riiHr„rt.;,)t, 2" 2.104 3.050 4.57 8.41 1.00 — r.po E.0 onion r Lm,H-1HIE--';i1 ti_Jy Hri 50 53.4 4.5 6.80 TiEi .51;-.loil He OC) riEses or-1 11..Trics El rri-:;Le — APPROVED i".:E.,:rt I : Hai;;tiHalict — HCcoe roo.FHJ P. a ;d;,:;';-i, uioLFv F1CF cc2tirli.4 can Made oi PH HE —IF t Fl 111 ,;';:l'il)ImaL in He f en ;Itoijor; rein-,tance (IL n::•;-'11;toi die CHFFTOEterr life eJiii.tetaricy ut EI pnjoikr. This is. lise.tj .ji Jit theI CT first •r- • ihe pipe (hr: cit 1.0'D 'LH' T E (.71-;ie;=1, ::1 IF Ir;-L",..7 31'0 LSI V,01411L.) Comparison to L.VV.T. Pipe E I I TI Hj—IIILit ai[ii HsjedI dr,/ son'IH e.'..-1C-11,S 7,nd FM:_sppro,.ed LC, I Dyna-Tliiifad— „H. Li :II - ; — IJIH,r; , ;T.(IH I F I ',See hist 1,;t: i iL ';; ;1 -p, — .0 FE Hi to 1) Flo;!„ ;:k HO Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: • Locations: Comments: Customer Service: (800)882-5543 Fax: (800)659-7730 www.alliedtube-sprinkler.com allied • 16100 5 Lathrop Ave • 11350 Norcorn Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 tkore ©2013 Atkore International, Inc.All Rights Reserved.STP-S3-4M-1301 Ductile Iron Threaded Fittings ...3.74.,r,„...... ......... _ ..„ . ...,....„,__ ""••••••••••-. ... .......... •'•-•"' 7.••••••••••,.. (-,,ire .. '..: .......„ .1' '.... ..'..• r_ . ...... •. ..•,,,, ,•• .e.: ., •,... . 1 •''. . .'-' -k .. '' I.,. 4.. , - ..."......f --.-- '. ---..... ---'7.-.- .. --..„ -......... 44'•• ...„, ..........._ • :';...., ---....., .-• .... ... , ''.. .14. •.1.1''''2.:`.",'.: s • ........ .. . v , - • .'.. . . .,• • .;.', .•. ..... • . ,l, - - . • "...i.• 4( , 1114 . , . .• if- . . . I . ._ s. I • . 1 • . ., . ... , , . .', .... ... ....— . --.- ,.. . .,-- ... -,...,_ . — - . .., 1-I _ ( . ) OI > I I Ductile Iron Threaded Fittings OltOifications • branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 c th. us LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 :'{' Ductile Iron Fittings - Class 300 UL/FM 1...,,-,,t' 7. c ® us APPROVED Fig. 35E 3-90°Elbow LISTED A Size A . Packing Weight io \ in; Part Number in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 _� i 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 1.11.11111-1/4 35E 3012 1.75 25` 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B , Size Part Number A B Packing Weight �___r_ --� in in in Inner Master lb \ 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 I� 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1x3/4 35RE3010006 1.38 1.45 50 100 0.4 IA1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 v 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 ' 2.39 2.60 6 12 2.5 1,/,' ' Fig. 35F 3-45°Elbow fi 7 Size A Packing Weight } -j Part Number '`A in in Inner Master lb f /\ �, 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 -` 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 I�l IA 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight in in Inner Master lb just.11 IA 1/2 35T 3004 1.13 80 160 60 0.3 3/4 35T 3006 1.31 30 0.5 1 351 3010 1.50 25 50 0.7 -�- 1-1.14 35T3012 1,75 10 - '20 1.1; A `�f A`' 1-1/2 35T 3014 1.94 10 20 1.5 2:- 35T 3020 - ,.225 6 - ...12 _2.4' 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER IN'T'ERNATIONAL® • 'POLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com r - Ductile Iron Fittings - Class 300 UL/FM c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED Size A B C Packing Weight Part Number ,. in in in in inner Master Ib , � C 3/4x 1/235RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 ------ --, 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 B A 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1x 3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1,44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 • 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 ' 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 • 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35RT3-Bull Head Tee Size Part Number A B C Packing Weight ��; in in in in Inner Master lb • Ic 3/4 x 1 35BT3006010 30060 0 1.45 1.45 1.37 30 60 0.6 • 1 1 x 1-1/4 B .1 1 -.`..7.. 1.6 ,. .. Q4. ..8 .- ..:67,. 1.C60..,:„.',.. 20 40 0.9 f--�' 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A B + 1-1/4 x 1 x 1-1/2:.' '35BT3012010014 •1.88 '. -1.80 1.82„ 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 j ,T,„ '114'x 2: 30i O` 2 10. - -,'-'116- 20 1.6' 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 :11-1/2X2a, 4.,-x 3 81301 *i 4t1 :' 4 'z` )3 _,..At. . `1.8.,-< SMITH-COOPER INI'ERNAI'IONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 - `fir }0 Ductile Iron Fittings - Class 300 UL/FM c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED A Packing; . Weight b.�.. Partum Number in' in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 11111 Size Part Number A Packing Weight p in in Inner Master lb 0.3 ® A 1 x 1/2 35R03010004 1.69 80 60 160 1 x 3/4 35RC3010006 1.69 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 'MrIA 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 11 I 1 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 '` • 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 A. Fig. 35SP3 -Square Head Plug 11 ps,: Size A Packing Weight Part Number ,_;_ in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 Irr A 3/4 35SP3006 1.12 350 700 0.1 1 iWilln I I 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat ASize Part Number A Packing Weight ��t��� in in Inner Master lb 1 35U 3010 2.19 20 40 1.0 I:I 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 alls�`.+� 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER IN'TERNA'TIONAL° • 'TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com ". -; "- ; Ductile Iron Fittings- Class 300 UL/FM Itii YF"" '` CIDuS 44110111. APPROVED Fig. 35X 3- Cross LISTED A )'�--' Size A Packing Weight Part Number Ong _ IA 1in in Inner Master lb 35X 3010 1.50 20 40 0.9 - ___�___ 1-1/4 35X 3012 1.75 12 24 1.4 � I A 1-1/2 35X 3014 1.94 8 16 1.8 11.1L2 35X 3020 2.25 6 12 2.8 B B Fig. 35RX3-Reducing Cross Size Part Number A B Packing Weight 6%ji ll� IA11 IN 1 III in in67 1.58 in Inner Master lb 1-1/4 x 1 35RX301 . 15 30 1.2 -i- 1-1/2 x 1 35RX3014012010 0 11.80 1.65 12 24 1.4 I IA 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C3-Cap • Size Part Number A Packing Weight I �\ inin Inner Master lb I IA 1/2 350 3004 0.87 300 600 0.1 . a I I 3/4 35C 3006 0.97 200 400 0.1 I 1 350 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 t: cr, Fig. 35BC3-Beam Clamp Size �� Weight in Part Number in Inner Master A Packing A 11113/8 35B03003 0.75 100 200 b 0.3 II ■' 1/2 35BC3004 0.75 80 160 0.5 • -- a SMI"1'H-COOPER IN'1'ERNA'I'IONAL® • 'POLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 , • pE'd e �"' f ® Fre t vds LPCB RE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical TA Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a"holefinder"locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and �y t size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order.Units are supplied painted with plated bolts.Galvanized hour- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE)pipe.Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic Tap Il®hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating:Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. • • Optional:Hot dipped galvanized Gasket:(Specify choice*) • Grade"E"EPDM • EPDM(Green color code).Temperature range—30`F to+230"F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services.UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30'C and hot+180'F/+82'C.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180'F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range.Not recommended for hot water services over+1507/+66°C or for hot dry air over+140'F/+60°C. `Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaullc Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER • System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com �CtaUi�C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �.._.�.._��... , t 11.02 STYLES 920 AND 920N DIMENSIONS Style Miz.Wok Apprax. Size No. Pre_sureCt Dimensions Weight Etch #eadmiltar . Man*" i" U4 ' ®e- w T Z. Md. iter Y� _� •.. worn :Apt . psi a�1:1 ye11es• i1leFal ladies •�(w• 1�7rdrec. ' 1116. 119dt; :;»..; .,,15:24041111 WR. .+1 - .,. 1:117'-'5514"1' . f1ala; �� 2 x 3k(a)o W N 500 1.50 250} 2.53 4 1.61 5.35 2.75 3.1 •... 1.5_ �- V �� 50 15 3450 381 51 64 41 136 70 1.5 /lit �^ riu ""'I 'T(a). 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 ,� �t - 20 3450 38.1 50 64 41 136 70 1.5 IU, Ir./ 1(a)0 920N 500 150 185 2.53 1,61 5.35 2.75 3.0 - \�7 d Nil 25 3450 38.1 47 64 - 41 136 7i; 1.4 1)/.(a)'° o_,i,N 530 1.75 255 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 ` 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2)a)to 0'0N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y > Z� 21/2 r, 1/2(a)6a 0'ON 500 1.50 2.21 2.74 - 1.82 5.64 2.75 3.0 1 65 15 345C 38.1 56 70 46 143 70 1.4 '/+(a)§n 920N 500 1.50 2.18 2.74 1.82 5.54 2.75 3.0 V V ;6, AI Sit T rig r 2C 3450 38.1 55 70 - 46 143 70 14 y r, 1(a)6025 0 500 1.50 2.06 274 - 182 5.54 2.75 2.97 - ? -I`I� t( 20PJ 50 3450 38.1 2.3052 3.000 46 143.270 1.4 \,/: lyl 1�/, (a)o 92ON 500 1.75 3.25 1.32 6.29 3.00 3.5 3.2 32 3450 44.5 58 75 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 11/2 t(a)a 02ON 500 2.00 2.28 3.00 325 1.82 6.26 325 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 'S(a) O_ 300 1.50 2.22 2.75 - 229 6.46 3.18 39 - 75.1 x 15 ON 2055 38.1 56 70 57 154 81 1.8 • Provides a direct branch connection at 3,4(a) 300 150 2.19 2.75 225 6.45 3.18 3.9 any location where a hole can be cut 20 9L0N 2065 38.1 56 70 - 57 164 81 1.8 - • in the pipe 1(a) -ON 300 1.50 2.07 2.75 - 2.25 646 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1'14(a)❑ 020N 50C 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 16 1.5 11/'..(a)o 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3x 1(a)t1 9';)N 500 1.50 2.52 3.05 2.29 6.15 2 75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.4 • Pressure rated up to 500 psi/3450 kPa 3/4(a). 9'ON 500 1.50 2.49 3.05 2.28 6.15 2.75 34 on steel pipe;also available for use 20 - 3450 38.1 53 78 - 58 156 70 1.6 - with HDPE pipe 1(a) 920N 500 1.511 238 306 _ 228 615 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.5 • Sizes from 2 x 1/2750 x 15mm (a)to 920N 500 1.75 255 3.25 3.56 2.28 6.15 3.00 3 8 3.7 through 8 x 47200 x 100 mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 11/2(a)to mON 500 2.00 2.78 3.5C 356 2.28 6.15 3.25 4.1 3.8 4C(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)❑ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 SO 9'_0N 3450 53.5 70 89 90 58 172 99 2.3 2,1 31/2 x 2 0,11N 500 2.50 3.00 - 3.75 2.44 6.72 3.88 - 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be ""Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. 8 Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT dearly on order. §Vds approved for fire protection services o LPCB approved for fire protection services C Approved for use in China by Tianjin Approvals Company. www.victaulic.com lctaulid VICTAULIC ISA REGISTERED TRADEMARK.OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY,ALL RIGHTS RESERVED. ._.___.. =:E, ; --1-il -1C., ,. 11.02 P T - 2 --. 1- c-,-.-'-.7:-., _ - -. ,...-:>, .-4,, , STYLES 920 AND 920N DIMENSIONS Style M.x.Work Approx. Size No. Pre_sureOO Dimensiens Weight Each _ Z-► am* ' 90 *A27 tecss hs Odin.leee lliie TRd�i tills ,l/is, v• look X11-,.:aek 4 ? TABLE CONTINUED FROM PAGE 2 o. � 4 x k(a). 9201 500 1.50 303 3.562.69 7.01 2.75 3 7 ,1�1 �1 siii t r IGG 15 3450 38.1 77 90 - 68 178 70G 1.8 - a)a 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 -1t�- 20 9'_ON 3450 38.1 76 90 68 178 70 1.8 111.IIIIN jib) / `y 1(a)a 500. 1.50 2.88 3.5o - 2.69 7.01 275 3 5 25 920N 3450 38.1 73 90 68 178 70 1_8 GROOVED OUTLET I Y(a)to 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 920N3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2(a)to9'_GN 500 2.00 3.28 400 4.00 2.69 701 3.25 4.2 3.9 rr y . r, Z 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 1 I SIR ? 2(a)to 920N 500 2.50 3.25 4,00 4.00 2,69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 tilil ^ 151, T til r 2'h(a)t 920 500 2.75 2.88 4.00 4.00 2.69 734 4.63 5.8 5.0 65 3450 699 73 102 102 68 186 118 25 23 V 75.1 mm 920 500 2,75 2,88 - 4.00 2.69 7.34 4,63 - 6.4 WIVO3450 69.9 73 102 68 186 118 29 y 3(a)t c,0 505 3.50 3.31 4.50 4.12 2.69 7.73 5.12 84 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET 1'/a(a)a 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 108.0 x 32 920N3450 44.5 78 96 67 194 78 2.3 11/2(3)0 500 2.00 3.28 4.00 --- 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 920N 3450 50.8 83 102 67 194 83 2.3 - any location where a hole can be cut 2(a) 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 in the pipe 50 92�'N 3450 63.5 83 102 67 194 102 19 76 c2, 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides .1 mm 3450 69.9 73 102 102 67 194 109 3.6 35 the seal 3(a) e,%, 500 3.50 3.31 4.50 4.50 2.53 7.63 4.88 5.8 5.5 80 R' 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 11/2(a)t c„.. 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 74 7.6 Mechanical-T cross assemblies 125 40 3450 50.8 102 121 121 80 245 94 3.4 3.4 2(a)t500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 c� • Pressure rated up to 500 psi/3450 kPa 50 •._v 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe;also available for use 21/2(a)tc 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 2u 3450 69.9 92 121 121 90 246 118 3.8 3.6 76.1 mm a c2i) 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 • Sizes from 2 x 1/2"150 x 15mm 3450 69.9 95 - 121 80 246 118 - 3.6 through 8 x 4"/200 x 100 mm 3(a)t 0,0 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 84 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 133.6 x 2 92C 500 2.50 3.75 4.50 - 3.17 8.00 3.88 80 Si) 3450 63.5 95 114 81 203 99 3.6 3 0,0 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 80 7 3450 88.9 97 127 76 240 135 3b TABLE CONTINUED ON PG.4 IMPORTANT NOTES: "Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved Gr female threaded cutlet.Specify choice on order. mated tc one another # Center of run to end of fitting. to achieve cross connections. V Female threaded cutlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly an order. (b)For 76.1 mm threaded outlet,specify 2W BSPT clearly on order. o Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com N1CtaaUhe VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. _.___._.„, 11.02 STYLES 920 AND 920N DIMENSIONS Stile Max.V✓ork Apr.,. Size No. Pie:surees Dimens on.; Weight Each TT: 1eamitollSW !O Otani*" !' r711t Cr.' W ' Z Tom. .td'R 0 _ k0 ► IPM 441.13IM I.s Odin Whet Ow** i9Ma ra- Um- tib a-1. I I-11-111W-.:-.c., - ..; 101414)'' OM -40I1t=:,-,11110;;•:: .-,..,!..1111L--r, ,,,+, -i MNI TABLE CONTINUED FROM PAGE 3 V11111,4111•00,...„0-- 141 �� 1397 x 11/2'I' 42ON 500 2.00 3.78 4.50 _ 3.30 8.23 3.25 70 _ 141 �1 m, I ri^r / 40 3450 50.8 96 114 84 209 83 3,2 - 4 ��l' 2 t 92ON 500 2.50 3.75 4.50 _ 84 209 3.889.0 1 � u 50 3450 53.5 95 4 84 209 99 4.1 7- \: (4....0 ,� (VI 5 x 1'/a(a) 920N 50C. 1.75 443 5.13 5.13 3.79 9.15 3.25 5,1 4.8 150 32(13) 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 11/2(a)to °''ON 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 420N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 y 1, Z 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2'h °2O 500 2.75 4,01 5.13 5.12 3.69 10.51 4.63 8.3 7.5 1 ^ - 65 3450 6°.9 110 130 130 94 267 118 3.8 3.4 ;Iris •�� nil', T rir 76,1 mm a 920 500 2.75 4.15 - 5.21 369 10-51 4.63 - 8.4 V ._ 3450 59.9 105 132 94 267 118 3.8 1 f y F T + 3(a)t c, 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 W IYI 80 3450, 88.9 110 140 130 94 267 135 4.6 3.8 y 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10-51 6.25 1C1.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 159.0 x 11/2(a) 920N 500 2.00 4.41 5.13 - 3.63 9.40 3.25 7.8 - 40 3450 50.8 112 130 92 239 83 3,5 2(a) 500 2.50 4.38 5.13 _ 3.63 940 3.88 8.0 • Provides a direct branch connection at 50 920N 345C 63.5 111 130 92 239 99 3.6 - any location where a hole can be cut 76.1mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 • in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 3450 88.9 110 14C 130 92 239 135 3.7 6.4 the seal 108.0 mm 920 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 - 10,0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 920 500 4.50 3.81 5.75 3.63 9.4C 6.25 18.0 Mechanical-T cross assemblies 100 3450 114.3 96.80 146 - 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa •f Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe;also available for use t Available with grooved or female threaded outlet.Specify choice on order. with HDPE pipe t Center of run to end of fitting. • Sizes from 2 x W/50 x 15 mm 6 Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4"/200 x 100 mm @ See page%fur Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services n LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cress connections, www.victaulic.com �CtaUliC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY,©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. .- __-_.. .____.,_,. 11.02 STYLES 920 AND 920N DIMENSIONS Slyle Mcx.Worki Apon,x. Size No. Preanec`i Dimensions Weight Each VilirrigYlandr ionamatstze 420 ' pialsoo10 A.• 7114 it 11 i , me. 401 . 0-...- .-Z . .' M ai Pit 3 IC. Was itstimIFMIB 41*i '. tit. UNE.- TABLE CONTINUED FROM PAGE 4 ^� x 1 SOD . 1.50 3.88 4.56 - 3.79 9.34 2.75 8.0 - V 165.1 x 9201 ' 'Iii �1 lil, l Ntr�ll.1 25 3450 38.1 99 116 96 237 70 3.6 ll _i"/_ 1�/0 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 ■ 92014 - 54 ffff v 32 3450 44.5 113 130 96 237 83 3.8 + 1'k(a)to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 84 5.4 40 3450 50.8 112 13C 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 438 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 27 6.1 mm o20 500 2.75 4.01 5.13 5.21 3.o3 10.51 4.63 8.6 76 Y . Z 3450 69.9 110 130 132 92 267 118 3.9 3.4 d' PR 1 3(a)t 0 Q.,0 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 �-.�I 80 3450 88.9 11C 140 130 92 267 135 4.6 3.8 V min �� oils, 7 `bill/ 4(a)to 920 500 4.50 3.81 575 5.38 3.63 10.51 6.25 10.5 84 ,i� + 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 �.f4 u + 8 x 2(a)l- 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.5 \N IMI 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 y 21/2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 500 2.75 5.25 _ 6.25 4.81 12.42 4.56 - 11.6 76.1 mm rs 920 3450 69.9 133 159 122 310 116 5.3 3(a)to020 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)fa 20 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 "Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal t Center cf run to end of fitting. • Request Publication 11.03 for V Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on osier. on steel pipe;also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services o LPCB approved for fire protection services • Sizes from 2 x 12150 x 15 mm ,3 Approved for use in China by Tianjin Approvals Company. through 8 x 4/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to i i to achieve cross connections. www.victaulic.com ICta'IUl1C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. _....--,......- I-,::,/ ._._tee.._....Cv it. = 11.02 STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-T®fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 0 Cv and Kv Values Values for flow of water at+60`F/+16°C are shown in the table below. • Formulas for C51K Values: DP = Q' Where: �P =_Q- /— Where: la /r� C., Q=Flow(GPM) K , —' \1'1/ Q Flow(m/h) DP=Pressure Drop(psi) pP=Pressure Drcp(br) Q = C x 4P =Flew Coefficient Q = K x /4P Where: =Flow Coefficient Exaggerarec for clo,iry Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213,Sec.76; OUTLET SIZE (C=120)t FT C./K,Valuas 2 sn ,',..`i :..'-.. 2 8 aye r . � A. � s ,a Y � e-k ` :-a !- ;� -. , � * e ,:- ., , _ , fi.' 1/2 0.840 11 - 15 21.3 9.4 y 1.050 4 16 20 26.7 13.7 1 1.315 8 21 25 33.7 - 1.8 • 1 Y 1.660 50 48 32 42.7 5 1/2 6 42.9 41.1 1,r5 1.900 53 53 40 98.3 11 11 45.4 45 4 2 2.375 112 1C4 50 60.3 9 10',,2 96 89.1 21/2 2.875 119 150 73.0 2C 2 102 128.5 76.1 mm 3.000 16* 161 76.1 138.1 3 3.500 249 237 80 889 14 15 h 213 4 203.1 4 4.500 421 401 100 114.3 2C �� 360.8 343.6 t Hazen-Williams coefficient,2f friction is 120. *Pipe with a wall thickness cf 0.165in✓4.2mm. www.victaulic.com \i taIUltC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED, _..._....�_....... 11.02 STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication.Listings/Approvals are subject to • change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures-psi/kPa iIIYM& r•" -,-,-.,',,f,„., i..-.Y.�, ,".a s � � �; ams 21/2-6 2.875-6.625 All W 10,40 400 400 400 M1 290 232 362 65-150 73.0-1683 2755 2755 2755 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 302 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3.4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2495 6 6.625 34 30 40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10.40 400 145 200 219.1 2755 — — — 1000 8 8.625 34 10, 300 _ 250 — 145 — 200 219.1 2065 1724 1000 8 8.625 54 �0 40 300 _ 300 — 145 — 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic Tap II Mechanical-T unit, 4-87100-200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II Is capable of tapping Into carbon steel pipe systems under pressures up to 500 psi/3450kPa. T The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100mm, I 57125mm,67150mm and 87200 mm diameterpStyle e.The 931 comes with a 21765mm grooved outlet. d _ The drill motor is an electric motor with ground fault circuit interrupter(GEC!)in accordance with safety codes. --- For more information,refer to publication 24.01. i .N www.victaulic.com �CtaUisC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED, ..»_—.,-_...... ,_CARBON STEEL PIPE-HOLE CUT PRQDUCTS 11.02 STYLES 920 AND 920N INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly Instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.vlctaulic.com 11.02 1480 REV M UPDATED 03/2012 jataUlIC VICTAULIC IS A REGISTERED TRADEMARF:OF VICTAULIC COMPANY.(^2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Pipe Hangers Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) C CO US Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig.2 OOS - "Trimline" Adjustable Band d Hanger with Non-Captured Nut Size Range: Fig, 200 - 11/ (lbmnx'thru 8" I'uorrm)pipe Material: Steel, Pre-Galvanized to G90 specifications 48. litio Function: For fire sprinkler arid other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation, Features: ,,, • (I/z" (15ri,rr;thru 2" (5u ....0mm1) Flared edges ease installation for all pipe types and protect CFVC plastic pipe from abrasion. Captured design -- i keeps adjusting nut from separating with hanger. Hanger is easily \f , B installed around pipe. e A I',. For hanger with non-captured nut order Fig. 200S. l \'� • (2112" (C5r,m( thru 8" (2nnmrn0 Spring tension on nut holds it securely in i hanger before installation.Adjusting nut is easily removed. , Approvals: Underwriters Laboratories listed (1/2" il 5mm)thru 8" (2uomr,i) Fig.200-1/2.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (u/a" (2ornmi thru 8" (200mrrt). Fig.200-1 to 200-2 Fig.zoo-2'hrozoo 200-8 Conforrns to Federal Specifications WW-H-171E&A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650`F(343°ci '�� � Finish: Pre-Galvanized. Stainless Steel ' materials •Hill be supplied with (2) he,nuts "}= ' in place of a knurl nut Order By: Figure number and pipe size: t4iv ; , a Is r- Designed to meet or exceed requirements of FM DS 2-0. •v:. 4 !,. Fig.200 Fig.200C Fig.200E , .=4 Pipe Size Rod Size A B Approx.Wt./100 �. Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) -+ + 200-1/2 I/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 15.01 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.51 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.71 12 (5.51 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) _.? - "r''' 200-3 3" (75) 3/8"-16 57/8" 1149.11 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 116.0) 200-5 5' 11251 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (1501 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (2001 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions In charts and on drawings are in inches.Dimensions shown in paientl.eses are in millimeters unless otherwise specified. Fire Protection Solutions B-Line 21 by E:T•N Threaded Accessories • B3205 - Threaded Rod (right-hand threads - both ends) (ToLCo Ag.103) B3205L - Threaded Rod (right& left hand threads) __.----------T::� �1 Size Range: 3/8"-16 thru 3"-4 rod Specify Length el Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. T\1�1��1��1 Rod is threaded on both ends with right hand threads of the length shown.Also available with left and right hand threads -specify Fig. B3205L when ordering. C' A Thread Size Maximum Temperature: 750`F 1399°C Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/s x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' S/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/0 x'1' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'1' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'1' 11/8"-7 41/2" 014.3) 7450 (33.14) 5830 (25.93) 83205-11/4 x'1' 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) B3205-11/2 x'1' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 83205-2 x'1' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 - All Threaded Rod Cut To Length 4# , Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length ) .1,'�� " ` Material: Steel c 0, )W"/ 0 Maximum Temperature: 750°F(399'C) Finish: Plain. Contact B-Line for alternative finishes and materials. g I aoe Order By: Part number,rod diameter and finish a Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATE 1/4"x 120 991/4"x length ' 20 240 (1.07) 12 (5.44) ATR 3/s"x 120 99-3/s"x length 16 730 (324) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATE s/s"x 120 99-5I8"x length 11 2160 (9.60) 89 (40.37) ATB 3/4"x 120 99-314"z length a 10 3230 (1437) 123 155.79) • ATR 7/s"x 120,' 99ye"x length 9 4480 (19.93) 170 (77.11) ")',ATR 1"lc 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports Rev sea 4 28i'Ota B-Line 236 by EA•N Beam Clamps B3031-318 - Light Duty Malleable C-Clamp 3/4" (19.0) Material: Malleable Iron I C ID US Function: Designed for attaching a 3/8"-16 hanger rod to the top or 1 1 17/a t/2" (47.6) LIISTEO bottom flange of a beam or bar joist when setscrew is in the down position ( .1) ', as shown. Approvals: Underwriters Laboratories Listed for up to 4" pipe. ConformsOA te4• Throat Opening to Federal Specification WW-H-1 71 E&A-A-1192A.Type 19 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58,Type 19. :-- ` r ' Finish: Plain or Electro-Galvanized ��� --- ':-.J Order By: Part number and finish. When retaining strap is required, 0� .7,..- order ' order Fig. 69 separately. See Page 37. Weight: Approx.Wt./100 25 Lbs.(11.3kg) Hanger Rod Set Screw and Not Included locknutIncluded Design Load: 350 Lbs.(1.55kN) Note: See page 27 for recommended setscrew torque. B3033 - Wide Jaw Reversible C-Clamp (TOLCO Fig.68) Size Range: 3/8"-16 thru 3/4"-10 rod c �\ > D Material: Cast Malleable Steel with hardened cup point set screw and jam nut <,,,,,,,,, ___,,,,, iCDi ---Cc' Function: For attachment to structural shapes requiring wider throat 8 E Throat Opening a' especially under roof with bar joist construction. 11/4"(31.7)for 83033-3/8&1/2 V This clamp may be used with the set screw in the up or down position. 15/16°(333)for 83033-5/8&3/4 = E A Approvals: Underwriters Laboratories Listed(cULus)and Factory (Rod Size) Mutual Engineering Approved(FM).Conforms to Federal Specification , -'�� Hanger Rod • WW-H-171 E Type 19&A-A-1192A,Type 19&23 and Manufacturers 1..k :(`R:,1, Not Included Standardization Society ANSI/MSS SP-69&SP-58,Type 19&23. s' Finish: Plain. Contact B-Line for alternative finishes and ., Set Screw and materials. Locknut Included , . Order By: Part number, rod size and finish ' Note: Do not over tighten set screw. CLIS LISTED Top Flange Attachment ■■ Applications P. ill 11111 isu L ® ® e Bottom Flange Attachment o .. ® Applications Part Rod Design Load with Setscrew Maximum Iron Approx. No. Size B C D Up Down Pipe Size Per UL WL/100 A in. (mm) in. (mm) in. (mm) Lbs. (kN) Lbs. (kN) in. (mm) Lbs. (kg) B3033-318 3/8"-16 21/4" (57.1) 2" (50.8) 11/8" (28.6) 610 (2.71) 610 (2.71) 4" (100) 54 (24.5) 83033-1/2 1/2"-13 25/16" (58,7) 23/16" (55.6) 11/4" (31.7) 750 (3,33) 1130 (5.02) 8" (200) ® (23.1) B3033-5/8 5/8 -11 25/8" (66.7) 21/2" (63.5) 12/8" (34.9) 750 (3.3331 1130 (5.02) 8" (200) 70 (31.7) 83033-3/4 3/4"-10 211/16" (68.3) 21/2" (63,5) 17/16" (36.5) 750 (3.33) 1130 (5.02) 10" (250) 98 (44.4) Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 30 by E:T•N Beam Clamps • Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 318"-16 thru 3/4"-10 rod O Component of State of California OSHPD Approved 4"(101.6mm)thru 16"(406.4mm)lengths C 1. US Seismic Restraints System Note: longer lengths are available consult factory LISTED Material: Pre-Galvanized Steel ®TOLCO Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas.Satisfies requirements of NFPA 13. 41111111111111 Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly.Therefore a locking mechanism of some kind. such as a hex nut or the beveled locking slot of the Fig.69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load spacing and placement information relating OSHPD projects. please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized Order By: Part number, length(L),and finish. Note: Minimum return on strap is 1"(25.4mm) i Hole Dia.D For Use With Length - - Part No. in. (mm) 69-3/8-L %/16" (30.1) 63033 3/s,83034-3/s,B3031-3/8, Specify - J 65-3/8,65XT-3/8,66-3/8 E - 69-1/2-L 9/16" (30.1) B3033-112,B3034-1/2,65-1/2,66-1/2 Specify 69-5/8-L 11/16" (50.8) B3033-5/s,65-5/8,66-5/8 Specify 69-3/4-L 13/16" (63.5) 83033-3/4 Specify JJ_ 1 P I' ) . 1 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by E-,i.N 37 Pipe Hangers&Supports