Report f1502\a s--000_ 2_ RECEIVED 7 ue, (t2c,s 3- FEB 12 2015 CITY OF TIGARD BUILDING DIVISION • . • � ,�- W yrAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 KIEHL' S 9585 SW WASHINGTON SQUARE RD SPACE F09 TIGARD, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL CO Worldwiderntacts Cowww.tyco-fire.com Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General stallation or finish. The tip of the Pro- tective Cap can be used to mark the OgiIft' Descry tion center of the ceiling hole into plaster p board or ceiling tiles by gently push- `__ The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- v "Royal Flush II" Concealed Pendent tective Cap. When ceiling installation _—�» - Sprinklers Quick Response (3-mm is complete, the Protective Cap is re- --, bulb) and Standard Response (5-mm moved and the Cover Plate/Retainer 0 bulb), are decorative sprinklers featur- Assembly is installed. ing a flat cover plate designed to con- As an option,the Series RFII Standard ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal. • TY35313 mm Bulb) is UL Listed, ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust ( Each sprinkler includes a Cover Plate/ Seal is intended for sensitive areas C-UL Listed, VdS Approved {Certif- y where it is desirable toprevent air and icate No. G4090007), and NYC Ap- Retainer Assembly and aSprinkler/ proved (MEA 353-01-E) as Quick Support Cup Assembly. The separa- dust from the area above the ceiling to Response. ble, two-piece assembly design pro- pass through the cover plate. vides the following benefits: • TY3531 (3-mm Bulb) is FM and NOTICE LPCB Approved (Ref. No. 094a/10) • Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response. and pressure testing of the fire pro- Factory Mutual and LPCB do not tection system prior to installation Sprinklers described herein must be y installed and maintained in compli- approve any concealed sprinklers of a suspended ceiling or applica- for quick response. ance with this document and with the tion of the finish coating to a fixed applicable standards of the National • TY3551 (5-mm Bulb) is UL Listed, ceiling. Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and ceiling panels for access to building ties having jurisdiction. Failure to do so NYC Approved (MEA 353-01-E) as service equipment without having may impair the performance of these Standard Response. to first shut down the fire protection devices. Approvals for Air and Dust Seal system and remove sprinklers. The owner is responsible for maintain- UL• Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de- , and C-UL Listed for use with the vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551). length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure sprinkler drops. with any questions. Maximum 250psi (17,3 bar) byUL, The Series RFII Sprinklers are shipped - C-UL,and NYC withProtective a Disposable Cap.The Sprinkler Protective Cap is temporarily removed p Maximum 175 psi (12,1 bar) by FM, during installation and replaced to help Identification VdS,and LPCB protect the sprinkler during ceiling in- Temperature Rating Number (SIN) 155 F(68`C)Sprinkler with IMPORTANT TY3531 — 3 mm bulb 139`F(59"C) Plate Always refer to Technical Data Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200`F(93'C)Sprinkler with WARNING" that provides cautions 165`F(74cC) Plate with respect to handling and instal- Technical Discharge Coefficient lation of sprinkler systems and com- K=5.6 GPM/psiii2(80,6 LPM/barvz ) ponents. Improper handling and in- Data stallation can permanently damage Adjustment a sprinkler system or its components Sprinkler Approvals 1/2 inch(12,7 mm) and cause the sprinkler to fail to Approvals apply only to the service • operate in a fire situation or cause it conditions indicated in the Design Cri- Finishes to operate prematurely. teria section. See the Ordering Procedure section. Page 1 of 4 MARCH 2013 TFP181 TFP181 Page 2 of 4 Physical Characteristics 1/2"NPTI. Frame Bronze ASSEMBLY Support Cup Chrome Plated Steel Guide Pins Stainless Steel FRAME I ; `' Of Deflector Bronze � Compression Screw Brass r � CAP Bulb Glass ' t--, Cap Bronze or Copper SUPPORT 1 , • Sealing Assembly Beryllium CUP WITH BULB Nickel w/TEFLON ROLL FORMED Cover Plate Brass THREADS Retainer Brass Ejection Spring Stainless Steel Design I 1 COMPRESSION SCREW GUIDE �/�. Criteria PINS!2) i , I- The TYCO Series RFII 5.6 K-factor, f, DEFLECTOR "Royal Flush II" Concealed Pendent �— `S� (DROPPED Sprinklers are intended for fire protec- DEFLECTOR , j_ / POSITION) tion systems designed in accordance -s with the standard installation rules rec- ognized by the applicable Listing or SPRINKLER/SUPPORT CUP Approval agency;for example,UL List- ASSEMBLY ing is based on NFPA 13 and VdS Ap- 1 proval is based on the CEA 4001. THREAD INTO ) I RETAINER For more information on LPCB and SUPPOTT ; WITH THREAD CUP UNTIL O DIMPLES VdS Approvals,contact Tyco Fire Pro- MOUNTING tection Products at the following office: SURFACE IS EJECTION Enschede, Netherlands FLUSH WITH SPRING Telephone:31-53-428-4444 CEILING Fax:31-53-428-3377 The Series RFII Concealed Pendent �J i■ � Sprinklers are only listed and approved `--/— with the Series RFII Concealed Cover Plates having a factory applied finish. SOLDER / '-----_ COVER TABS(3) COVER PLATE/RETAINER PLATE NOTICE ASSEMBLY Do not use the Series RFII in applica- FIGURE 1 tions where the air pressure above MODEL RFII CONCEALED SPRINKLER the ceiling is greater than that be- ASSEMBLY low. Down drafts through the Sprin- kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in- sprinkler operation in a fire situation. sufficient adjustment in the Sprinkler The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- Operation "Royal Flush II" Concealed Pendent kler/Support Cup Assembly.Re-adjust Sprinklers must be installed in accor- the position of the sprinkler fitting to When exposed to heat from a fire, the dance with this section. suit. Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the Retainer at three points, falls away to Do not install anybulb-type s sprinkler if pendent position with the center-line expose the Sprinkler/Support Cup p of the sprinkler perpendicular to the Assembly. the bulb is cracked or there is a loss mounting surface. y of liquid from the bulb.With the sprin- The Deflector — supported by the kler held horizontally, a small air bub- Step 2.Remove the Protective Cap. Guide Pins — then drops down to its ble should be present. The diameter Step 3. With pipe thread sealant ap- operational position. of the air bubble is approximately 1/16 plied to the pipe threads, hand-tighten The glass bulb contains a fluid that ex inch (1,6 mm)for the 155°F(68°C) and the sprinkler into the sprinkler fitting. pands when exposed to heat. When 3/32 inch(2,4 mm)for the 200°F(93°C) Step 4. Wrench-tighten the sprinkler the rated temperature is reached, the temperature ratings. using only the RFII Sprinkler Wrench. p (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as glass bulb,activating the sprinkler and should be obtained by applying a min- shown in Figure 3. allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap ft.-lbs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms of torque can distort the sprinkler In- out against the Support Cup. (Refer let with consequent leakage or impair- to Figure 4.)The Protective Cap helps ment of the sprinkler. prevent damage to the Deflector and TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE - --SPRINKLER DIAMETER - ' HOLE FITTING DIMENSION C SPRINKLERri lel'• i. SUPPORT CUP ASSEMBLY I a 1I2"(12.7 mm) 1 THREADED e1 �"IT" i D ADJUSTMENT ��I FACE `► —_�__.. __MI__ OF CEILING. RETAINING RING ! I ""'�/ MOUNTING SURFACE j ill �,- >]��► � FIGURE 4 r ,�, 'Mi.- 1 `• /, DISPOSABLE PROTECTIVE CAP .__J1-------• t l �. Arms during ceiling installation and/or Jfinish.You can also use the Protective I \\ c T i \v Cap to locate the center of the clear- 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE ance hole by gently pushing the ceiling (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of REFERENCE 3/32"(2.4 mm) POSITION ASSEMBLY the Protective Cap. COVER PLATE COVER PLATE NOTICE -PROFILE DEPTH DIAMETER As long as the Protective Cap remains DIMENSION B DIMENSION A in place, the system is considered A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service". Step 6.After the ceiling has been com- B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) pleted with the 2-1/2 inch(63,5 mm)di- ameter clearance hole and in prepa- FIGURE 2 ration for installing the Cover Plate/ SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis- card the Protective Cap.Verify that the Deflector moves up and down freely. -- If the Sprinkler is damaged and the =l FRAME �` Deflector does not move up and down r. Iu �/ ARM �� i% lfro n replace toe odify repair a Do not attempt to modify or repair adamaged sprinkler. SUPPORT 1 ( Step 7. When installing an Air and CUP - I Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air yand Dust Seal, verify the angle of the C• —�� outside edge of the seal is oriented ac- I■' �4 cording to Figure 5. Start the edge of --_-------- Retainer d of Annink 8° (23 mm) Ell Airthe andRtainDust Seal inthe andgroovecontinueslot around SQUARE —`, the retainer until the entire Air and Dust N Seal is engaged. �J-`\ Step 8. Screw on the Cover Plate/ ALIGN Retainer Assembly until the Retainer ARROWS WITH 6(17.- i 1 (shown in Figure 2)or the Air and Dust FRAME ARMSSeal (shown in Figure 5) contacts the ', 7ceiling. Do not continue to screw on ( the Cover Plate/Retainer Assembly 1111 ACCEPTSso that it lifts a ceiling panel out of its 1/2" SOCKET-_ \� normal position. If you cannot engage DRIVE ` the Cover Plate/Retainer Assembly FIGURE 3 with the Support Cup or you cannot RFI/SPRINKLER WRENCH engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Care and SUPPORT -------.- SPRINKLER FACE OF ORIENT CUP / CEILING �1 SEAL Maintenance �/ BEVEL AS ij_iii. t___ / ,, / SHOWN The TYCO Series RFII 5.6 K-fac_ I IPTE /tor, "Royal Flush II" Concealed Pen , RETAINER dent Sprinklers must be maintained ASSEMBLY ii�u�rar and serviced in accordance with this Cl % section. _ - Before closing a fire protection system 'Ilk ' ,..) AIR main control valve for maintenance A �'■'� �I 'i \�work on the fire protection system that AND DUST it controls, obtain permission to shut =._•--_ —. LIP OF COVER SEAL down the affected fire protection sys- RETAINER PLATE tern from the proper authorities and FIGURE 5 notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) ed by this action. Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Ordering Assembly can delay sprinkler opera- reinstall it or a replacement without re- tion in a fire situation. installing the Cover Plate/Retainer As- Procedure ur•e When properly installed, there is a sembly. If a Cover Plate/Retainer As- �l nominal 3/32 inch(2,4 mm)air gap be- sembly becomes dislodged during Contact your local distributor for tween the lip of the Cover Plate and the service,replace it immediately. availability. When placing an order, ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the full product name. sectimaintenance o This air gap is necessary for proper their fire protection s, anystem and devicf Sprinkler/Support Cup Assembly operation of the sprinkler. If the ceil- es in compliance with this document, Specify: Series RFII (specify SIN), ing requires repainting after sprinkler as well as with the applicable stan- K=5.6, "Royal Flush II" Pendent Sprin- installation, ensure that the new paint dards of the National Fire Protection klers (specify) temperature rating and does not seal off any of the air gap. Association(e.g., 25), in addition NFPA (specify)finish, P/N(specify). Do not pull the Cover Plate relative to to the standards of any other authori- the Enclosure.Separation may result. ties having jurisdiction.Contact the in- 155`F 168'0) 200`F 193°C) stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200 Sprinklers which are found to be leak- facturer regarding any questions. TY3551 51-790-1-155 51-790-1-200 ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/ inspected,tested,and maintained by a Retainer Assembly: Automatic sprinklers must never be qualified Inspection Service in accor- painted, plated, coated, or other- dance with local requirements and/or Specify: (temperature rating from be- wise altered after leaving the factory. national code. low) Series RFII Concealed Cover Modified sprinklers must be replaced. Plate with(finish),P/N(specify). Sprinklers that have been exposed to 139'F(59`C)(a) 165'F(74°°C)(b) corrosive products of combustion, but Gray White have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165 if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165 by wiping the sprinkler with a cloth or Pure White(c' by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165 Signal White Care must be exercised to avoid dam- (RAL9003) 56-792-4-135 56-792-4-165 age to the sprinklers - before, during, Jet Black and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165 aged by dropping, striking, wrench Brushed twist/slippage,or the like, must be re- Chrome 56 92-8-135 56-,92-8-165 placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165 has a cracked bulb or that has lost Custom 56-792-x-135 5,6-792-x-1e5 liquid from its bulb. (Ref. Installation (a) For use with 155 F(68'C)sprinklers. Section.) (b) For use with 200'F(93'C)sprinklers. Exercise care to avoid damage to (CI Eastern Hemisphere sales only. sprinklers before, during, and after in- Sprinkler Wrench stallation.Replace sprinklers damaged Specify:RFII Sprinkler Wrench, by dropping, striking, wrench twisting, P/N 56-000-1-075. wrench slipping, or the like. Also, re- place any sprinkler that has a cracked Air and Dust Seal bulb or that has lost liquid from its Specify:Air and Dust Seal, bulb.(Refer to the Installation section.) P/N 56-908-1-001. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright®2013 Tyco Fire Products,LP. All rights reserved. NCO TEFLON is trademark of The DuPont Corporation. VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers " { Description described herein must be installed and maintained in compliance with this doc- . The TYCO Series TY-FRB,5.6 K-factor, ument,as well as with the applicable Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- ` `It are quick response,standard coverage, dards of any other authorities having - 4 • decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so mayoverageMin sprinklers designed for use in light or the performance of these devices. .--__-:r' = "''"`' ordinary hazard,commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and .`f - devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with _;_..;< ble,is intended for use in areas with a any questions. finished ceiling.This recessed pendent I sprinkler uses one of the following: �, • A two-piece Style 15 Recessed Sprinkler . Escutcheon with recessed adjust- Identification '° ment up to 5/8 inch (15,9 mm)from 1.., e , the flush pendent position. - �:•- , ,-„v„,, ”` Number (SIN) - „ • A two-piece Style 20 Recessed • Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT Li: ...• the flush pendent position. -`0" The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175°F(79°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(1141 C)) Technical Data Sheet TFP357.Sprin- FM,LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)° Button Brass/Copper 'The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories.Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM;psi1t2(80.6 LPM/bart12) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and corn- - ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. .111 Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11.1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 5 /`1 7;'16" / (11.1 mm) I \'■fes 4 _ NOMINAL 2" 0 \ (i 2 It MAKE-IN (7/ (50.8 mm) / L_ 2 p. a 9. 2, \H (1/ 1-3/8" �/ IP (50.8 mm) $ - (34.9 mm) /1 lir 3 "= WRENCH 1 � f i � FLATS 1/2" NPT** DEFLECTOR* 2-7/8"(73.0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, , ...y.° WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally,a small air CH bub- Criteria ble should be present. The diameter WREN RECESS of the air bubble is approximately 1/16 The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and / Upright(TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. /� �1 tion systems designed in accordance wsstaoules eA leak-tight 1/2 inch NPT sprinkler joint ognizedith by thetandard applicableinListingrrop Approvalthe agency (such as,n UL Listingc-r imumshould tobe maximumobtained by torqaueplying of 7a tomin 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels �/ is based on the requirementsllatiof NFPA %Ye 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH of the sprinkler. Data Sheets).Only the Style 15 or Style IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the uptight position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 2-7i8"DIA. _ 6 Sprinkler Wrench(Figure 2).With ref- (73.0 mm) erence to Figure 1, apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15.9 mm) Recessed Pendent Sprinklers 1 • FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" -- ----11 l I Sprinklers must be installed in accor- (9.5±7.9 mm) IN dance with the following instructions. 'C' I ' t Step A.After installing the Style 15 or MOUNTING // –� 1/$ 1 Style 20 Mounting Plate over the sprin- SURFACE -/ (3,2 mm) kler threads, and with pipe-thread sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34.9 mm) hand-tighten the sprinkler into the TY-FRB PLATE sprinkler fitting. 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the into Wthe SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7spriRecessed Sprinkler Wrench(Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73.0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER f_2-1/4"DIA. ishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) . Closure over the Series TY-FRB Sprin- 5/16±1/4" 7 12. kler and push the Closure over the (7.9±6.4 mm) 1/2"( mm) Mounting Plate until its flange comes in - FLUSH contact with the ceiling. T/ / _--.,-1 I ,, ,7 j j ,% Care and I MOUNTING Ili 1/8„ J Maintenance SURFACE // (3,2 mm) / The TYCO Series TY-FRB,5.6 K-factor, " I I Upright(TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned by wiping the sprinkler with a cloth or Automatic sprinkler systems are rec- escutcheon, which is used to cover by brushing it with a soft bristle brush. ommended to be inspected, tested, a clearance hole, can delay sprinkler and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation.Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like,must be replaced. with a feather duster;otherwise,non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the • ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document,as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 g PURE WHITE(RAL9010)" 155 155'F(680C) POLYESTER SIGNAL WHITE(RAL9003) 371 5.6K PENDENT(1/2"NPT) TY323 4 POLYESTER 175 175°F(79'C) •Use suffix"I"for ISO 7-1 connection: 9 CHROME PLATED 200 200`F(93'C) foi a/ample.77-670-1-175-I Eastern Hemisphere sales silly 286 286'F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish,P/N(specify*) ' Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 • GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright 0 2014 Tyco Fire Products,LP. All rights reserved. t co TEFLON is trademark of The DuPont Corporation. ��''ff Fire Protection Products Dyna-Thread® - M-COAT® Submittal Data Sheet Full Line Sch-40 Replacement Dyna-Thread-M-COAT Specifications r T" „,,-IE NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR 1 _i,, • - In;mm In;mm Lbs/Ft;kg/m Lbs/Ft kg/m Unthreaded Threaded 1" 1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 -11/4" 1.408 1.870 2.54 9 50 1.00 Comparison to Sc.heclule 40 32 35.8 2.8 3.78 -11/2" 1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 4.79 2" 2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 Dyna-ThRad :;;; cC) Lhi.k e s_S [ii,t 1 dead— 11PopgYEq -`_ r:,1:413(11 .I' C r I,' I- D., tled�—1American Made lidaIfn li_, is f`_ Iciaa.I t0I let -til :.i�`i•il, t_rC .5i I h.a l I T`?,' �; LCL �ct,l -.I rC_'Jt!'11ei L h��1'i:.1� ri til 1,e tar ct _iiia inlhi. Tills is L I II:7 �� tlr t t)lbc 1 tIile3TI ti r,-.-i I ',I•` v 1 tHa —i ='li [nna-TIMI Irlt f' `_ �'�- ��- �� 1�.t�li� ':111t vf�a T� 7i— _lji` l - -_'I -t:'• :FF 1 T-,iEEI I t ',a' — ' Comparison to L.W,T. Pips -f. 1 -- ri _-i - -.I dry;nI�!t �,IG-`ter. Niuo I ��I n h� TI„r. ��'ii �� q rl Ind GIt,�I I _ 1 I re � -� �tl _ �`— __, _ I' {,_ n _Tli Laa _ _ -_ JI ii th'G.c�ie - ',I i -E. Ii �." -_ hrsSr _ 1 n —l'l-. . 1;:;',";."4;" .'I p Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: • Locations: Comments: a Customer Service:(800)882-5543 Fax: (800)659-7730 www.alliedtube-sprinkler.com n allied • 16100 5 Latl�roN Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT- Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 °P"p'°`Aatkore ©2013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1 301 40-j_. Ductile Iron Fittings - Class 300 UL/FM c ® us APPROVED Fig. 35E 3-90°Elbow LISTED A °,- Size yf - A. _- Packing Weight „�.� Part Numuer \ in in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 r 140 0.3 I1i.1j1i.11- A 1 35E 3010 1.50 40 80 0.5 1/4 35E 3012 ' 1.75 25- „ 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 ;.,•. :' 2:25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B Packing Weight i ) in Part Number in in Inner Master Ib 11111 -irk 3/4 x1/2 35RE30060041.20 1.22 80160 0.3 1 x 1/2 35RE3010004 - 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1 45 50 100 0.4 7�' �A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1,0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 Ay, '.-,' 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 tt; 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2,2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size A Packing Weight Part Number OA A in in Inner Master lb�, 1/2 35F 3004 0.88 150 300 0.2 %#%\ 3/4 35F 3006 0.98 80 160 0.3 -` 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1 0 ��� A 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size part Number A Packing Weight in in Inner Master Ib 1/2 35T 3004 1.13 80 160 0.3 gib ,.., A 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1 � 1-1/4 _ 35T:3012 1151;., w,.,.s: 10 29, 1.1 a A A 1-1/2 35T3014 1.94 10 20 1.5 2 ,' ':- -'-':'41:4020.- -,.,2. 4 f ,t 12 ,•' .:-- 2-1/2 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com mss. Ductile Iron Fittings - Class 300 UL/FM c ® us 44> APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size ., A -: Packing - Weight -�• Part Number in in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200_ 02 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 -2.00 35 70 05 1-1/2 35CP3014 219 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 1111 Size Part Number A Packing Weight /Aim in inInner Master Ib A 1 x 1/2 35R03010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight 1 ' T B in in Inner Master lb i 1 , 1 x 1/2 35H63010004 1.06 180 360 0.2 �A 1 x 3/4 35HB3010006 1.06 180 360 0.1 , 1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 0.4 1-1/2 x 1 35HB3014010 1:25 75 150 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35H,83020010 138 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 "' •v 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 4.fa� i Fig. 35SP3 -Square Head Plug Size A Packing Weight :4 in Part Number in Inner Master lb Mi 1/2 35SP3004 0.94 600 1200 0.07 II VA 3/4 35SP3006 1.12 350 700 0.1 Ili1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 - Fig. 35U 3- Union with Brass Seat A Size A Packing Weight Pail Number in in inner Master lb --. 1 35U 3010 2,19 20 40 1.0 1-1/4 351.1 3012 2.50 • 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 ..2. .. 35U 3020 , - 3.12 ,..,: `6 . 12 _„,:., ..2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • ww.wsmithcooper.com Pipe Hangers Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ® roLco Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) " c 0 US Fig.200C "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Line Fig.B311ONFC) urn Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/1" ilbmmi thru 8" !7OOmmi pipe Material: Steel, Pre-Galvanized to 590 specifications e W. Function: For fire sprinkler and other general piping purposes. Knurled �,____. swivel null design permits hanger adjrlstment after installation. Features: i • (1/2" (15r,rri thru 2" innmmr) Flared edges ease installation for all pipe ''"'' 6 types and protect CPVC plastic pipe from abrasion. Captured design - ) keeps adjusting nut from separating with hanger. Hanger is easily 'k, A B installed around pipe. ,. A 1. For hanger with non-captured nut order Fig. 200S. • 12'/2" !s5r,m1 thru 8" zoon,m;; Spring tension on nut holds it securely in ( , 1 `„.: ,,,, ,,/ hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed(1/2" 1 5mn-o thru 8" (2uomru) Fig 200-1/2.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and t Factory Mutual Engineering Approved(FM) (q4" 12ornn l thru 8" (20omrr1). Fig.zoo-tmzoo-z Fig.zg0-21lztozoos Curfornis to Federal Specifications WW-H-171 E&A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, ....- Type _Type 10. Maximum Temperature: 650"F(51:=•ci Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) he.. nuts in place of a knurl nut. Order By: Figure number and pipe size f Designed to meet or exceed requirements of FM DS 2-0. Fig.200 ;: . Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 I/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3I4 3/4" (20) 3'8"-16 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" 185.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4" (321 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.41 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) . 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) -4- 200-3 3' (75) 3/8"-16 57/8" (149.1) 4" 1101.6) 29 (13.31 Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (1333) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8' (187.3) 5" (127.01 35 (16.0) 200-5 5" (1251 1/2'-13 91/8" (231.8) 61/4" (158.71 66 (30.2) 200-6 6' (150) 1/2-13 101/8" (257.2) 63/4" (171.41 73 (33.4) 200-8 8' (200) 1/2"-13 131/8" (333.41 83/4" (222.2) 136 (62.3) All dimens ons in...naris aha on d dA ings die in inches.Dirnensions shown n pe'entheses are in millimeteis unless othe'wn,e specified. B-Line Fire Protection Solutions 21 by E:?•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCo Fig.103) B3205L - Threaded Rod (right& left hand threads) TL ,) Range: 3/e" 16 thru 3" 4 rod Specify Length Size �� r - Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL ,�1 Rod is threaded on both ends with right hand threads of the length shown.Also ���V�' A available with left and right hand threads -specify Fig. B3205L when ordering. Thread Size Maximum Temperature: 750°F 399°Ci Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number. rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 x'L' 3/t'-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-51e x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/8x'L' 7/e"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x'L' 11/s"-7 41/2" 114.31 7450 (33.14) 5830 (25.93) 83205-11/4 x'1' 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) 83205-11/2 x'L' 1112"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'1' 13/4"-5 7" (177.8) 18600 >82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"41/2 9" (228.6) 32300 (143.67) 25295 (112.51) • B3205-21/2 x'1' 21/2"-4 10" +,254.0) 39800 (177.03) 31169 (138.64) 83205-23/4 x'1' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 83205-3 x 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 - All Threaded Rod Cut To Length 11; n Size Range: 3,18"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length C� , Material: Steel m Maximum Temperature: 750°F(399 C) . o` . Finish: Plain. Contact B-Line for alternative finishes and materials. P.'5 L V Order By: Part number, rod diameter and finish I-Q Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (RN) Lbs. (kg) ATRIA"x 120 99-1/4"X length 20 240 (1.07) 12 (5.44) ATR 3/8"X120 99-3/8"x length 16 730 (324) 29 (13.15) ATR!/"x 120. ,99-112".x length 13 1350 (6.00) 53 (24.04) 99.$,F" lenge:: 11 2160 (9.60) 89 (40.37) WA "1t g1l.. 10 3230 (14.37) 123 (55.79) a a ® 9 4480 (19.93) 170 (77.11) D.3717.7E. e. I 8 5900 >26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ......-Line■ Pipe Hangers&Supports 236 Rev sed 4 28/201i by E:T"N Beam Clamps B3031-3/8 - Light Duty Malleable C-Clamp 3/4" (19.0) Material: Malleable Iron \ C® us • Function: Designed for attaching a 3/8"-16 hanger rod to the top or i 171.6 11/2" 147.6) USTED bottom flange of a beam or bar joist when setscrew is in the down position (38.1) =_• as shown. Approvals: Underwriters Laboratories Listed for up to 4" pipe. Conforms ��� %bits Throat Opening to Federal Specification WW-H-171E&A-A-1192A.Type 19 and \=` 11/16"(17.5) Manufacturers Standardization Society ANSI/MSS SP-69&SP-58,Type 19. ',",rr>� Finish: Plain or Electro-Galvanized /0 =) Order By: Part number and finish. When retaining strap is required, --- .411, order Fig. 69 separately. See Page 37. Weight: Approx.Wt./100 25 Lbs.(11.3kg) Hanger Rod Set Screw and Not Included Locknut Included Design Load: 350 Lbs.(1.55kN) Note: See page 27 for recommended setscrew torque. B3033 -Wide Jaw Reversible C-Clamp (TOLCO Fig.68) Size Range: 3/8"-16 thru 3/4"-10 rod c 1''•� > D Material: Cast Malleable Steel with hardened cup point set screw and jam nut Function: For attachment to structural shapes requiring wider throat B E Throat Opening a especially under roof with bar joist construction. we(31.7)for B3033-31a&1/2 (.4! L 0 This clamp may be used with the set screw in the up or down position. 15/16"(33.3)for B3033-5/s&3/4 _ /L CIA Approvals: Underwriters Laboratories Listed(cULus)and Factory (Rod Size) Mutual Engineering Approved(FM).Conforms to Federal Specification -� V,�i Hanger Rod WW-H-171 E Type 19&A-A-1192A,Type 19&23 and Manufacturers .• Not Included 111100 Standardization Society ANSI/MSS SP-69&SP-58,Type 19&23. a. 4 .1 Finish: Plain. Contact B-Line for alternative finishes and i 5 ',�, set screw and 1". Locknut Included • materials. Order By: Part number, rod size and finish .a cST us Note: Do not over tighten set screw. .' LISTED ....opo Top Flange Attachment IL Applications EN I .M11 I ri:.: 1.2- Bottom Flange Attachment e IN a Applications Part Rod Design Load with Setscrew Maximum Iron Approx. No. Size B C D Up Down Pipe Size Per UL WtJ100 A in. (mm) in. (mm) in. (mm) Lbs. (kN) Lbs. (kN) in. (mm) Lbs. (kg) B3033-318 3/8 -16 21/4" (57.1) 2" (50.8) 11/8' (28.6) 610 (2.71) 610 (2.71) 4" (100) 54 (24.5) 83033-1/2 1/2"-13 25/16" (58.7) 23/16" (55.6) 11/4" (31.7) 750 (3.33) 1130 (5.02) 8" (200) ® (23.1) 5 /8 5 83033-. i8" 11 25/8" (66.7) 21/2" (63.5) 1"/8' (34.9) 750 (3.33) 1130 (5.02) 8" (200) 70 (31.7) • B3033-314 3/4"-10 211/16" (68.3) 21/2" (63.5) 17/16" (36 5) 750 (3.33) 1130 (5.02) 10" (250) 98 (44.4) Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 30 by EA-IPA Beam Clamps Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3/8"-16 thru 3/4"-10 rod Component of State of California OSHPD Approved • 4"(101,6mm)thru 16"(406.4mm) lengths CC)US Seismic Restraints System Note: longer lengths are available consult factory LISTED Material: Pre-Galvanized Steel ®TOLCO Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. 41114111111 Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly.Therefore a locking mechanism of some kind. such as a hex nut or the beveled locking slot of the Fig.69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD), For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized Order By: Part number, length(L),and finish, Note: Minimum return on strap is 1"(25.4rnm) Hole Dia.D For Use With Length il Part No. in. (mm) f_ 69-�/s-L 'hs" (30.1) B3033-3/5,B3034-315.83031-3/s. Specify = um 65-3/s,65XT-3/s,66-3/8 M ii 69-1/2-L 9/16" (30.1) B3033-112,B3034-112,65-1/2,66-1/2 Specify 69-518-L 11/16" (50.8) B3033-5/8,65-5/8.66-5/8 Specify 69-3/4-L 13/i6" (63.5) B3033-3/4 Specify I ii = All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by E:T•N 37 Pipe Hangers&Supports