Report Technical Data
- "K"Factor Sprinkler Identification
Sprinkler Number(SIN)
Sprinkler Type US Metric Height Approvals SSU SSP
Standard-Upright(SSU)and Pendent(SSP)
Deflectors Marked to Indicate Position
y"(15 mm)Standard Orifice with y2"NPT(RX)Thread 5.62 81.0 2%" (73 mm) 1,2,3,4,5,6,7 R1025 R1015
%6"(11 mm)Small Orifice with}Z"NPT(Ry)Thread 4.24 61.0 2%," (73 mm) 1,3,7 R1023 R1013
X"(10 mm)Small Orifice with y2"NPT(R}2)Thread 2.82 40.6 2'/e" (73 mm) 1,2,3,7 R1021 R1011
%6'(8 mm)Small Orifice with y"NPT(RX)Thread 1.98 28.5 2'/e" (73 mm) 1,3,7 R1022 R1012
"/32"(20 mm)Large Orifice with y"NPT(R}9 Thread 7.96 114.7 2'/e" (73 mm) 1,2,3,7 R1026 R1016
'%2"(20 mm)Large Orifice with%"NPT(RY)Thread 8.20 118.2 2'916" (75 mm) 1,2,3,7 R1027 R1017
20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5,6 R1027 R1017
10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4,5,6 R1024 R1014
Conventional—Installed in Upright or Pendent Position
10mm XLH with 10mm Thread 4.10 59.1 73 mm 5 R1074
15mm Standard Orifice with(R,3) Thread 5.62 81.0 73 mm 4,5,6 R1075
20mm XHH with(R3/,)Thread 8.20 118.2 75.4 mm 4,5 R1077
Temperature Ratings Maintenance
Maximum Model G Sprinklers should be inspected quarterly and the
Sprinkler Ambient sprinkler system maintained in accordance with NFPA 25. Do
Rating Temperature Frame(1) not clean sprinklers with soap and water,ammonia or any other
Classification °F °C °F °C Color cleaning fluids. Remove any sprinkler that has been painted
Ordinary 135 57 100 38 Black (other than factory applied)or damaged in any way.A stock of
Ordinary 165 74 100 38 Uncolored spare sprinklers should be maintained to allow quick replace-
Intermediate 212 100 150 66 White ment of damaged or operated sprinklers. Prior to installation,
High 286 141 225 107 Blue sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
(1)Frame color does not apply to painted or plated sprinklers sprinklers that would cause improper operation or
-Use sprinkler rating as identified on operating parts. non-operation. Use only the Model D Sprinkler Wrench for
sprinkler removal and installation.Any other type of wrench may
damage the sprinkler.
Finishes(1)
Standard Finishes Approval Organizations
Bronze —All Temperature Ratings 1. Underwriters Laboratories, Inc.
Chro —All Temperature Ratings 2. Factory Mutual Research Corporation
Whited ) —All Temperature Ratings 3. Underwriters' Laboratories of Canada
Only Frame and Deflector are Painted 4. Loss Prevention Council
Special Application Finishes 5. Pleniere Assemblee
ung
Bright Brass Plated —Only frame,deflector and cap are plated. 135°F(57°C),165°F 6. N.Y.C.VS SBS&A No. 5 7-7
(74°C),212°F(100°C)Temp.Rating. 7. N . MEA 83-E-75-SA or
N.Y.C. MEA 258-93-E
Black Plated —Only frame,deflector and cap are plated.All Temp.Ratings.
Polyester Coated(2) —Only frame and deflector are coated.
Lead Plated —165°F(74°C),212°F(100°C)and 286°F(141°C)Temp.Ratings. Ordering Information
Wax-Coated(3) —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. Specify
Wax-Coated Over 1. Model G
Lead Plated(3) —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. 2. Deflector
•Upright
(1) Other colors and finishes are available.Consult factory for details. •Pendent
(2) UL listed and NYC MEA Approved only. •Conventional
(3) 212°F(100°C)brown wax may be used on 286°F(141°C) 3. Nominal Orifice
sprinklers when maximum ambient temperatures do not exceed 150°F 4. Inlet Thread
(66°C).UL Listed,FM Approved,NYC MEA 258-93-E. 5. Temperature Rating
6. Finish
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual
Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States,Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co.,Inc.
e
,;Rabid
(800)(800)431848--6051 Paper
1588 Sales Fax
Rimed
Sales Fax
(914)829-2042 Corporate Offices Revision lines indicate updated or new data.
www.reliablesprinkler.corn Internet Address EG.Parted in U.S.A 11/04 PM 9999970005
Bulletin 172 Rev. E
Model JL112&J112-Pendent co
® ECLH-Extended Coverage Light Hazard `�
ECOH-Exte� ded Coverage Ordinary Hazard N
• ECOH-Extended Coverage Ordinary
Hazard-Quick Response rn
Model JL112 & J112 ECLH/ECOH SIN RA7216 is Corrosion Resistant with White
Pendent & Recessed Pendent Polyester Coating.
(SIN R7216- Link and RA7216- Bulb) „ -- �: .� .a
• Quick Response for Light Hazard F ...
(16'x16'(4.9mx4.9m),18'x18'(5.5mx5.5m)and . ' 4,
20'x 20'(6.1m x 6.1m) spacing) 1;,
• Quick Response for Ordinary Hazard �; .�= y �
(12'x 12' (3.7m x 3.7m)and 14'x 14' (4.3m x 4.3m) �. 1!? '
spacing) 4,,
• Standard Response for Ordinary Hazard ' ”�' . "�,��
(16'x16'(4.9mx4.9m),18'x18'(5.5mx5.5m)and �*
iat
20'x 20' (6.1m x 6.1m)spacing) *.
- '
Features .: • ,t. .y ,.
1. Extended Coverage Ordinary Hazard and Light Hazard '`
protection to 400 ft2(37.2 m2)per sprinkler. > Model JL112 Pendent Model J112 Pendent
2. Nominal K= 11.2(160). (R7216)- Link (RA7216)- Bulb
3. Available in Pendent or Recessed Pendent styles.
4. Recessed pendent version provides 3/4"(19mm)adjust- This ECLH/ECOH sprinkler is available in various finishes,
ment to flush pendent position(see adjustment table). which includes a white polyester corrosion resistant finish.
5. Available in brass, chrome and polyester coated ECLH/ECOH sprinklers are available in a pendent or an
finishes. attractive recessed pendent type which provides up to 3A"
6. For applications as per NFPA 13. (19mm)of escutcheon adjustment.
Approvals Organizations Design Criteria
1. Underwriters Laboratories, Inc.(UL) Reliable Model JL112 & J112 ECLH/ECOH sprinklers
2. Underwriters Laboratories of Canada(cULus) shall only be used in systems designed and installed in
UL Listing Category accordance with NFPA 13 and all other local codes and
Sprinklers,Automatic and Open Extended Coverage Sprin- ordinances.The following design criteria also apply:
klers-Ordinary Hazard Occupancy UL Guide Number—VNIV. •
Minimum sprinkler spacing is 8 ft(2.44m).
The Reliable Model JL112 and J112 sprinkler are Extended • Sprinklers have a minimum flow requirement for each
Coverage Sprinklers for use in both Light and Ordinary Hazard spacing as shown in the Flow Requirements Table on
1 and 2 occupancies with a coverage area of up to 400 square the reverse side.
feet(37.2m2)per sprinkler. For ordinary hazard applications it • Sprinklers are only to be used in systems hydraulically
is a Standard Response Sprinkler. designed per NFPA 13.
For all light hazard applications it is a Quick Response sprin- •
Deflector to commodity clearance shall be a minimum
kler. For ordinary hazard applications, it is a Standard Re- of 18 inches(457mm).
sponse sprinkler when the spacing is 16'x 16'(4.9m x 4.9m) •
ECOH sprinklers shall be installed in unobstructed
and larger.When the spacing is 12'x 12'(3.7m x 3.7m)or 14'x constructions as defined in NFPA 13. For open web
14'(4.3m x 4.3m),the sprinkler is Quick Response for ordinary truss construction web thickness is not to exceed 1
hazard applications. inch (25.4mm).
The use of ECLH/ECOH sprinklers can provide lower instal- • ECOH sprinklers which are installed above the bottom
lation costs by requiring fewer sprinklers, less piping and re- of a horizontal obstruction, shall have their deflectors
duced labor. located as shown in the Obstruction Table on page 3.
ECLH/ECOH sprinklers are to be installed according to the • Sprinklers can be installed under a sloping ceiling
design criteria shown in this bulletin,NFPA 13,and all other lo- not exceeding 2 inches(50.8mm)of rise in 12 inches
' cal codes and ordinances. Flows and pressures as shown on (304.5mm).
pages 2 and 3 of this bulletin,must be used for the appropriate • Maximum working pressure is 175 psi(12.1 bar)at the
spacing and for the designated hazard classifications. sprinkler.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Sprinkler Model Specifications
Temperature Max. Maximum Maximum
RatingCeiling Sprinkler Coverage THD
Sprinkler Model Type Temp. Spacing Area Size Approvals
'F °C °F `C ft(m) ft2(m2)
JL112 ECLH/ECOH-R7216 Link/Pendent 165 74 100 38
212 100 150 66 20(6.1) 400(37.2)
JL112 ECLH/ECOH-R7216 Link/Recessed 3/."NPT
J112 ECLH/ECOH-RA7216 Bulb/Pendent 155 68 100 38 (19mm) 1,2
J112 ECLH/ECOH-RA7216 Bulb/Recessed 200 93 150 66 20(6.1) 400(37.2)
Flow Requirements-Light Hazard-Quick Response
Spacing Coverage Area Flow Pressure "K"Factor
ft(m) ft2(m2) gpm(Ipm) psi(bar) US Metric
16 x 16(4.9 x 4.9) 256(23.8) 30(113.6) 7.2(0.5)
18 x 18(5.5 x 5.5) 324(30.1) 33(124.9) 8.7(0.6) 11.2 160.0
20 x 20(6.1 x 6.1) 400(37.2) 40(151.4) 12.8(0.9)
Flow Requirements-Ordinary Hazard-Standard Response
Ordinary Hazard 1 Ordinary Hazard 2
Coverage 0.15 gpm/ft2(6.1 Umin/m2) 0.20 gpm/ft2 (8.1 Umin/m2) "K"Factor
Spacing Area Density Density
ft(m) ft2(m2) Flow Pressure Flow Pressure US Metric
gpm(Lpm) psi(bar) gpm(Ipm) psi(bar)
16 x 16(4.9 x 4.9) 256(23.8) 39(147.6) 12.1 (0.8) 51 (193.0) 20.7(1.4)
18 x 18(5.5 x 5.5) 324(30.1) 49(185.5) 19.1 (1.3) 65(246.0) 33.7(2.3) 11.2 160.0
20 x 20(6.1 x 6.1) 400(37.2) 60(227.1) 28.7(2.0) 80(302.8) 51.0(3.5)
Flow Requirements-Ordinary Hazard-Quick Response
Ordinary Hazard 1 Ordinary Hazard 2
Coverage 0.15 gpm/ft2(6.1 Umin/m2) 0.20 gpm/ft2 (8.1 Umin/m2) "K"Factor
Spacing Area Density Density
ft(m) ft2(m2)
Flow Pressure Flow Pressure
gpm(Lpm) psi(bar) gpm(Lpm) psi(bar) US Metric
14 x 14(4.3x4.3) 196(18.2)
30(113.6) 7.2(0.5) 39(147.6) 12.1 (0.8) 11.2 160.0
12 x 12(3.7 x 3.7) 144(13.4)
2.
Recess Escutcheons Recessed Pendent ECLH/ECOH Adjustments 0)
• ECLH ECOH
Escutcheon
F1/F2 FP R7216 RA7216 R7216 RA7216
FP 3/4(19.0) 3/4(19.0) 3/4(19.0) 3/4(19.0)
F1 (2) (2) 3/a(19.0) 3/a(19.0)
- F2 'h(12.7) Y2(12.7) Y2(12.7) 1/2(12.7)
.Cri-7....''''71..,� •+, (1)Adjustments in inches(mm).
'-1%...,-;.,,,„:. --'-t� t�- �r J (2)Not listed by UL or cULus.
lr -.
- , t.
Finishes
"` Sprinkler Finishes
Sprinkler Escutcheon
Model J1 Bronze Brass
Sprinkler Wrench Model RJ Chrome Chrome
Use Model J1 Wrench for Sprinkler Wrench White Polyester Coated White Painted
JL112&J112 ECLH/ECOH Use Model RJ Wrench for JL112
Pendent Sprinkler Removal &J112 ECLH/ECOH Recessed
and Installation Sprinkler Removal and Installation
Ordering Information
J1 Wrench RJ Wrench 1. Sprinkler Model
2. Temperature Rating
ynf 3. Finish
' ,,.ea" N1 I 4. Escutcheon and finish (where applicable)
r
,....r''''- Corrosion Resistant
Bulb
e °F °C
4 J112 ECLH/ECOH
1,, 4_,`" 155 68
200 93
Minimum Flow Requirements For Earlier Editions of NFPA 13- FOR REFERENCE ONLY
NFPA13-1991 Requirements NFPA13-1989 Requirements "K"Factor
Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 3
0.15 gpm/ft2 0.20 gpm/ft2 0.16 gpm/ft2 0.19 gpm/ft2 0.21 gpm/ft2
Spacing Coverage (6.1 Umin/m2) (8.1 Umin/m2) (6.5 Umin/m2) (7.7 Umin/m2) (8.6 Umin/m2)
ft(m) ft Area Density Density Density Density Density US Metric
( ) Flow Pressure Flow Pressure Flow Pressure Flow Pressure Flow Pressure
gpm psiL psi gpm psi gpm psi gpm
( Pm) psi(bar)
(Lpm) (bar) (bar) (Lpm) (bar) (Lpm) (bar) (Lpm)
14 x 14 30.2 7.0 39.2 11.9 31.4 7.6 37.3 10.7 41.2 13.0
(4.3 x 4.3) 196(18.2) (114.3) (0.48) (148.3) (0.82) (118.8) (0.52) (141.2) (0.74) (155.9) (0.90)
and less
16 x 16 256(23.8) 38.4 11.4 51.2 20.2 41.0 12.9 48.7 18.2 53.8 22.3
(4.9 x 4.9) (145.3) (0.79) (193.8) (1.39) (155.2) (0.89) (184.3) (1.26) (203.6) (1.54) 11.4 164.4
18 x 18 324(30.1) 48.6 18.2 64.8 32.3 51.9 20.7 61.6 29.2 68.0 35.7
(5.5 x 5.5) (184.0) (1.24) (258.9) (2.23) (196.4) (1.43) (233.2) (2.01) (257.4) (2.46)
20 x 20 400(37.2) 60.0 27.7 80.0 49.3 64.0 31.5 76.0 44.5 84.0 54.3
(6.1 x 6.1) (227.1) (1.91) (302.8) (3.40) (242.2) (2.17) (287.7) (3.07) (317.9) (3.75)
3.
Installation Requirements for Under Concrete Tees - cULus
• The stems of the concrete tee construction must be spaced at less than 7.5 feet (2.3m) on center but more than
3 feet (0.9m) on center. The depth of the concrete tees must not exceed 30 inches (762mm). The maximum
• permitted concrete tee length is 32 feet (9.8m); however, where the concrete tee length exceeds 32 feet (9.8m),
non-combustible baffles, equal in height to the depth of the tees, can be installed so that the longitudinal space
between the tees does not exceed 32 feet(9.8m) in length.
• The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch(25.4mm)below the bottom of the
concrete tee stems.
• When the sprinkler deflectors are located higher than a horizontal plane 1 inch(25.4mm)beneath the bottom of the
concrete tee stems,the obstruction to sprinkler discharge criteria requirements of NFPA13 for extended coverage
upright sprinkler applies.
Location of Deflector to Horizontal Obstruction , t3/16'DA-�
r.9.Im"J
Distance from S rinkler Maximum Allowable Distance r- J __ ,
P Deflector Above Bottom of '=__�__ _=�_ „
to Side of Obstruction
Obstruction TURN couwa UNTIL 1 I
WRENCH BOSS.
I
Less than 1' 0" r`I`"'"`"`°"'� I ,`' __
y :J/d r6o.J mo�,.
(Less than 0.305m Omm) i i -1 ti I I a.
•
1'to less than 1'-6" 0" t%%'T% _=
(0.305m to less than 0.305m-152.4mm 0mm) T-r'."`4-- =_ "L 5/,6"(3J.6 m)
1'-6"to less than 2' 1" �,o,Solrwrl 0.11: 111i11 '., `"o a
(0.305m-152.4mm to less than 0.61m 25.4mm) 1� ,�� p �l� ,//i r�'Jr-�
11x1;7 t -rt;
2'to less than 2'-6" 1" v�_=I'l
(0.61m to less than 061m-152.4mm 25.4mm) /a- ..,„-
,..,,r, j�
2'-6"toless than 3' 1" `--
(0.61m
-inkL
(0.61 m-152.4mm to less than 0.915m 25.4mm)
_.,
3'to less than 3'-6" 3"
(0.915m to less than 0.915m-152.4mm 76.2mm) ..7__]
--1.65 ien
3'-6"to less than 4' 4"
(0.915m-152.4mm to less than 1.22m 101.6mm) - 2(iilmmj�
4'to less than 4'-6" 5"
(1.22m to less than 1.22m-152.4mm 127mm) Fig. 1 - F1 Escutcheon
4'-6"to less than 5' 7"
(1.22m-152.4mm to less than 1.525m 177.8mm)
5'to less than 5'-6" 7"
(1.525m to less than 1.525m-152.4mm 177.8mm)
5'-6"to less than 6' 7"
(1.525m-152.4mm to less than 1.83m 177.8mm)
6'to less than 6'-6" 9"
(1.83m to less than 1.83m-152.4mm 228.6mm)
6'-6"to less than 7' 11"
(1.83m-152.4mm to less than 2.135m 279.4mm)
7'and greater 14"
(2.135m and greater 355.6mm)
Solder Link Bulb
Classification °F °C Link Color Classification °F °C Bulb Color
Ordinary 165 74 Black* Ordinary 155 68 Red
Intermediate 212 100 White Intermediate 200 93 Green
* 165°F chrome plated and white painted sprinklers will contain a white painted solder link.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory
Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries.
• Manufactured by
The Reliable Automatic Sprinkler Co.,Inc. ® Recycled
® (800)484381---61508581 Sales Offices Paper
eli
d (800) Sales Fax Revision lines indicate updated or new data.
(914)8292042 Corporate Offices
www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.08/12 PN 9999970310
Bulletin 014 Rev.J
co
'tell- ® Model Fl FR Series (17
Quick Response
V.
Standard Sprayai
o
Model Fl FR56 Sprinkler Types
I Standard Upright Ititail -•
Standard Pendent f Z"'
Conventional ^' ;' 1 . g
"11Vertical Sidewall /
Horizontal Sidewall ,. 1/ tt 411
Model Fl FR56 Recessed Sprinkler Types
I Standard Panrl nt/F1/F2/FP I Upright Pendent Conventional
Horizontal Sidewall ` `
Model Fl FR56 Concealed Sprinkler Types _ , J.
Standard Pendent r `r "`r • ( `t, ` '*
Model Fl FR42, F1 FRXLH & Fl FR28 Sprinkler .` za -
Types Vertical Sidewall Horizontal Sidewall Recessed
Standard Upright Pendent/Fl/F2
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Recessed � �. : _,� �
Sprinkler Types ' ���kkk� ,4 i " _w,,61)t
Standard Pendent I. 'ir-
t
. Model Fl FR56LL&F1FR42LL Low Lead Sprinkler .., .
Types* Recessed Concealed Recessed
Standard Pendent Horizontal Sidewall Pendent Pendent/FP
• Less than 0.25%Lead Content
Listing & Approvals t ;
1. Underwriters Laboratories Inc. and Certified for ■`' _
Canada(cULus). `
2. Factory Mutual Approvals(FM) n
3. Loss Prevention Council(LPCB, UK) XLH Upright XLH Pendent XLH Recessed
4. VdS Schadenverhutung GmbH Pendent F1/F2
5. *NSF Certified to NSF/ANSi Standard 61 Annex G to apply water to a fire much faster than
UL Listing Category --standard sprinklers of the same tem- .- :.
Sprinklers,Automatic&Open(VNIV) perature rating.
Quick Response Sprinkler The glass bulb consists of an accu-
rately controlled amount of special fluid
Product Description hermetically sealed inside a precisely
Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, manufactured glass capsule.This glass XLH Recessed
F1 FRXLH & F1 FR28 Series Sprinklers are quick response bulb is specially constructed to provide Pendent FP
sprinklers which combine the durability of a standard sprin- fast thermal response.
kler with the attractive low profile of a decorative sprinkler. At normal temperatures, the glass bulb contains the fluid
The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, in both the liquid and vapor phases. The vapor phase can
F1 FRXLH & F1 FR28 Series Recessed automatic sprinklers be seen as a small bubble. As heat is applied, the liquid
utilize a 3.0 mm frangible glass bulb.These sprinklers have expands, forcing the bubble smaller and smaller as the liq-
demonstrated response times in laboratory tests which are uid pressure increases. Continued heating forces the liquid
. five to ten times faster than standard response sprinklers. to push out against the bulb, causing the glass to shatter,
This quick response enables the Model Fl FR56,F1FR56LL, opening the waterway and allowing the deflector to distrib-
Fl FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Series sprinklers ute the discharging water.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
•
Application
Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick
• response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
*Pin tle
(XLH Only)
Deflector
‘ -1'
Load Screw
Washer Bulb
Frame / Cup
t_
1a1 �
014FGO6A
Model F1FR42,F1FRXLH Upright
Technical data:
Max. Min.
Thread Temperature
Models Discharge Coefficient Response hrSiee Working Working Rating Finish
Pressure Pressure
F1FR56 K 5.6
"F1 FR56LLt')
F1FR42 Quick 1/2"NPT See See
"F1FR42LL!'► K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table"
F1FRXLH Ratings"Table.
F1FR28 K 2.8
(1)Low Lead Sprinklers available only with Temperature Rating 200°F/93°C
Material Data:
Frame Deflector Load Screw *Pintle Cup Washer Bulb
DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360
CDA Alloy 220
QM Brass or or or coated with PTFE Adhesive Glass
Or
**Low Lead Brass CDA AlIoy510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
•
2.
Model Fl FR56, Upright, Pendent & Conventional Sprinklers
Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Thread Nominal K Factor Sprinkler Approval
Sprinkler Identification Number
Nominal P (SIN)
Orifice
Size US Metric Height Organization Upright Pendent
Standard-Upright(SSU)and Pendent Deflectors Marked to Indicate Position
1/2"(15mm)0) 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,2,3,4 RA14250)(2)(3) RA14140x2x3)
7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) 1 RA14230) RA1413
3/8"(10mm) 1/2"NPT(R1/2) 2.8 40 2.25"(57mm) 1 RA14210) RA1411
Conventional-Install in Upright or Pendent Position
15mm 0) 1/2"NPT(R1/2) 5.6 80 57mm 3,4 RA1475(3)
(')cULus listed corrosion resistant(Polyester coated)sprinkler.
(2)Polyester coated FM approved sprinkler.
(3)Polyester coated LPCB&VdS approved sprinkler RA1425,RA1414&RA1475.
Or, , . .. ,
•
Upright Pendent Conventional
Model Fl FR56LL & Fl FR42LL Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number
(SIN)
Orifice
Size US Metric Height Organization Pendent
Standard-Pendent Deflectors Marked to Indicate Position
1/2"(15mm)0) 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,5 RA1414
7/16"(11mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) 1,5 RA1413
0)cULus listed corrosion resistant(Polyester coated)sprinkler.
Ca
• 4 µ
t.
3.
•
Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(')
- Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Sprinkler Identification Number
Orifice Size US Metric Height (SIN)
1/2"(15mm) 1/2"NPT(R'h) 5.6 80 2.25"(57mm) RA1414
7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) RA1413
3/8"(10mm) 1/2"NPT(R1/2) 2.8 40 2.25"(57mm) RA1411
")Refer to escutcheon data table for approvals&dimensions
Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(')
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Sprinkler Identification Number
Orifice Size US Metric Height (SIN)
1/2"(15mm) 1/2"NPT(RY) 5.6 80 2.25"(57mm) RA1414
7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) RA1413
(1)Refer to escutcheon data table for approvals&dimensions
_ I I I-X v2-REDUCER
�' 2 a/a'D,a(azhrvn] -----r-----
r----T AW
i, MOI'AV C[587
.yr Am x,
lUlfx Kim C01ma'`R -- I e/ra'da[saw]
FACE a MaeCUPII
Po FACE a'Mw oAlvacw
I I - I ;,Fenndrev "" J
I { I A KKK*,RECESS.r71SImnJ 1FACE
ACE OF
FRYING
1YIll1 t,. .LIM. AIK,.wArarr.r/,T,a.., �:..II.
YI or, . Al -3/•,jr,••47 ( II u uArRIDIIR 7g- r-F/1'r ri
AOASRIEM AT Flamm.AraA-VII"AK) AI IANYRAI RECESS- I ]S.Imm
1111 AT Kow Aran.r T.Is.,,.] -I*ml4
AT
LL4YMN RECESS-9/16714.Jm
"J
y7xa.r •e• Al AYiIA7 RECESS-1j2544,,],41.24:744,24
_
NAIaKawAI Bag::r-sA2so) }
24._
[82 84n481
F
Model F1FR56,F1FR56LL,F1FR42,F1FR42LL,F1FRXLH& Model F1FR56,F1FR56LL,F1FR42,F1FR42LL,F1FRXLH&
F1FR28 F1 or F2 F1FR28 FP
Model Fl FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal K Factor Sprinkler
Nominal Thread Size Sprinkler Approval Identification
Orifice US Metric Height Organizations
Numbers(SIN)
'/z"(15mm) '/z"NPT(R1/2) 5.6 8.0 2.25"(57mm) 1,2,3,4 RA1485(2)
15mm 1/2"NPT(R1/2) 5.6 8.0 2.25"(57mm) 40)
(1)LPC Approval is for pendent position only.
(2)cULus Listed corrosion resistant(Polyester coated)sprinkler.
Sprinkler Type Deflector to Ceiling Distance
4sr k (Min.-Max.)
Upright 4"(102mm)- 12"(305mm)
tF .:.
AO.' r Pendent 4"(102mm)- 12"(305mm)
• i
Vertical Sidewall
4.
Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler
• Deflector:HSW
Installation Wrench:Model D Sprinkler Wrench
Installation Data: Horizontal Sidewall
Nominal K Factor Sprinkler Approval Organizations Sprinkler
Height and Type of Approval
Nominal Orifice Thread Size Identification
Ordinary SIN
US Metric Light Hazard Numbers Hazard (SIN)
1/2"(15mm) 'h"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435(1x2)
(1)cULus Listed corrosion resistant(Polyester coated)sprinkler.
I cn Polyester coated FM approved sprinkler.
FACE OF FITTING
TO FACE OF CEILING DIMENSION
Fl ESCUTCHEON A
AT MAXIMUM RECESS 1725.4mm]
AT MINIMUM RECESS = 3/879 5mmj / El ESCUTCHEON
F2 ESCUTCHEON / AT MAXIMUM RECESS = 1-.3/8734 9mm1
", AT MINIMUM RECESS = 2-1/16752 4mm]
1,.:4''. AT MAXIMUM RECESS = 3/4[19mm]
; AT MINIMUM RECESS = 3/8 79.5rom] F2 ESCUTCHEON
Y AT MAXIMUM RECESS = 1-5/8741 3mm]
'' �.. ..m 4...::9$ , -2 1/4"HOLE DL4. 1/8" AT MINIMUM RECESS = 2-1/16752 4mmj
VG f '' 7 st [572mmJ
" '' "*' ... 1"X 1/2"REDUCER
r r
A _
1Gr
-'',� (I)
Horizontal Sidewall 1 15/16"DLA. 1 'IIS- 4 'Z
i .�_ (101.6mm-.3O4.8mm]
[49.2mm] �dl 2 27/32"DL4. CEILING TO
1 L-r °) [72.2mm] DEFLECTOR
L_
TURN COLLAR UNTIL
III !
TIGHT AGAINST SPRINKLER
WRENCH BOSS. �, F1 ESCUTCHEON
3/4719mm]ADJUSTMENT
—_• 12 ESCUTCHEON
1/2[12.7mm]ADJUSTMENT
.,....A.RECESSED HSW W/F1 OR F2 ESCUTCHEON
(1) FM APPROVED FOR 4"- 6"[101.6MM - 152.4MM]CEILING TO DEFLECTOR.
Note: For Recessed HSW Sprinklers use installation wrench GFR2.
Model Fl FR56 Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
"K"Factor Temp.Rating Max. Sprinkler
Nominal Thread Model Ambient Bulb Approvals Identification
Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN)
1/2"(15mm) 5.6 80 'h"NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414
1/2"(15mm) 5.6 80 1/2"NPT F1FR 155°F/68°C 135F/57°C 100°F/38°C Red 1,40> RA1414
1/2 (15mm) 5.6 80 1/2"NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1 RA1414
'//"(15mm) 5.6 80 1/2"NPT F1FR 200°F/93°C 165°F/74°C 150°F/65°C Green 1 RA1414
I'1 For VdS only= 155°F/68°C Norbulb and 1/2"[12,7mm]adjustment.
Model Fl FR56LL Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
"K" Factor Temp.Rating Max. Sprinkler
Nominal Thread Model Ambient Bulb Approvals Identification
Orifice US Metric Size Sprinkler CoverTemp Color Number(SIN)
1/2"(15mm) 5.6 80 1/2"NPT F1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1,5 RA1414
•
5.
•
1"x 1/2"REDUCING• 1"x 1/2"REDUCING
TEE OR ELBOW `.__ TEE OR ELBOW ''�
ii .il1-
llI
11._ ll I W._.._..J
�-, I r-` 2 5/8"DIA. 1-� —Iy r-� 2 5/8' DIA.
2 5/16" DIA — HOLE IN CEILING 2 5/16""0/A — HOLE IN CEILING
CUP ��_=�� _
I(.rjLl 1 1/2"MAX. CUP 1114 — 1 1/2"MAX.
o .,;:I- k FACE OF FITTING
�,"I ��'�"' -�� FACE OF FITTING 7� NryO '��
J „Itie---
15/16"
l TO FACE OF CEILING
ilii i �r.-
TO FACE OF CEILING I
Jji,,;��: ISI III „,,:,,, „� T—,—��% DIMENSION
� �7- — —._ DIMENSION „t�. 1'�':.:5555JCEILING \� "CEILING t \1/2" MAX. � 5/16"MA3/4"'COVER ADJUSTMENT COVER ADJUSTMENT 11
COVER PLATE— I I
COVER PLATE— 1 ASSEMBLY 3 5/16"DIA.ASSEMBLY 3 5/16" DIA. I /
/ SPRINKLER
SPRINKLER
CONCEALED. 1/2" ADJUSTMENT n nm. CONCEALED. 5/16" ADJUSTMENT mnoou
Figure 1 Figure 2
Installation Aid
A protective cap is included for use during installation. gagement.A choice of two cover plate assemblies provide
Jmportant:The Fl FR56 Sprinkler with Model CCP cover either 1/2"(13mm)or 5/8"(8mm)of cover adjustment,
plate is not an FM Approved combination. Do not install these sprinklers in ceiling which have positive
Installation pressure in the space above.
Quick response sprinklers are intended for installation as After a 25/8"(67mm)diameter hole is cut in the ceiling,the
specified in NFPA 13. Quick response sprinklers and stan- sprinkler is easily installed with the Model RC1 Wrench. A
dard response sprinklers should not be intermixed. Teflon*based thread sealant should be applied to the sprin-
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, kler threads only. The Model RC1 Wrench is then used to
F1FRXLH & F1FR28 Recessed Quick Response Sprin- engage the sprinkler wrenching surfaces and to install
klers are to be installed as shown. The Model Fl or F2 Es- the sprinkler in the fitting. When inserting or removing the
- cutcheons illustrated are the only recessed escutcheons wrench from the sprinkler/cup assembly,care should be tak-
to be used with the Model F1FR56, F1FR56LL, F1FR42, en to prevent damage to the sprinkler. DO NOT WRENCH
F1FR42LL, F1FRXLH&F1FR28 Sprinklers. The use of any ON ANY OTHER PART OF THE SPRINKLER. The cover
' other recessed escutcheon will void all approvals and ne- plate is then pushed onto the cup. Final adjustment is made
gate all warranties. by hand turning the cover plate until the skirt flange makes
When installing Model F1FR56, F1FR56LL, Fl FR42, full contact with the ceiling. Cover plate removal requires
F1FR42LL, Fl FRXLH & F1FR28 Sprinklers, use the Model turning in the counter clockwise direction.
D Sprinkler Wrench.Use the Model GFR2 Wrench for install- After installation, inspect all sprinklers to ensure that there
ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & is a gap between the cover plate and ceiling and that the
F1FR28 Recessed Pendent Sprinklers. Any other type of four cup slots are open and free from any air flow impedi-
wrench may damage these sprinklers. ment to the space above.
NOTE: A leak tight' " NPT (R1/2) sprinkler joint can be Concealed cover plate/cup assemblies are listed only for
obtained with a torque of 8-18 ft-lbs(10,8- 24,4 N-m). Do use with specific sprinklers. The use of any other concealed
not tighten sprinklers over maximum recommended torque. cover plate/cup assembly with the Model F1FR56 Pendent
It may cause leakage or impairment of the sprinklers. Sprinkler or the use of the Model CCP Concealed cover
The Models F1 FR56/CCP & F1 FR56LUCCP Concealed plate assembly on any sprinkler with which it is not specifi-
Sprinkler use the 1/2" orifice, 1/2" NPT(R1/2), Model F1FR56 cally listed my prevent good fire protection and will void all
&F1FR56LL Pendent Sprinkler with a threaded Model CCP guarantees,warranties,listings and approvals.
cup which is factory attached to the sprinklers. The Model Glass bulb sprinklers have orange bulb protectors to
F1FR56 Pndent is available in temperature rating of 135°F minimize bulb damage during shipping, handling and in-
57°C , 155°F 68°C , 175°F (79°C) or 200°F (93°C). The
stallation. REMOVE THIS PROTECTION AT THE TIME THE
Model F1FR56LL Pendent is available only in a rating of SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE
200°F(93°C).The concealed sprinkler assemblies are corn- PROTECTION. Removal of the protectors before this time
pleted by the installation of the attractive low profile Model may leave the bulb vulnerable to damage. RASCO wrench-
CCP push on cover plate assembly, rated 135°F(57°C) or es are designed to install sprinklers when covers are in
165°F(74°C)for the Fl FR56 and 165°F(74°C)for the FIFR56 place. REMOVE PROTECTORS BY UNDOING THE CLASP
LL.The cover plate and sprinkler cup assemblies are joined BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO-
using a cover plate skirt with flexible tabs for threaded en- TECTORS.
*DuPont Registered Trade Mark
6.
Temperature Ratings Finishes (1)
- Sprinkler Max.Ambient Standard Finishes
Classification Temperature Bulb Color Sprinkler Escutcheon Cover plater')
°C °F Temp. Bronze Brass
• Ordinary 57 135 100°F(38°C) Orange Chrome Plated Chrome Chrome
Ordinary 68 155 100°F(38°C) Red Polyester Plated White
Intermediate 79 175 150°F(66°C) Yellow Coated(4)(5)(6) White Painted
Intermediate 93 200 150°F(66°C) Green Special Application Finishes
High i" 141 286 225°F(107°C) Blue Sprinkler Escutcheon Cover plate")
i"Not available for recessed sprinklers. Bright Brass(3) Bright Brass Bright Brass
Black Plated Black Plated Satin
Escutcheon Data(1) Black Paint(2)(6) Black Paint Off White
i"SIN RA1435—cULus permits use with Fl,F2 or FP escutcheons for"light Off White(2)(6) Off White Black Paint
hazard"only,while FM limits use for same hazard with F2 escutcheon only. Satin Chrome Satin Chrome Black Plated
i"Other finishes and colors are available on special order.Consult the
Maintenance factory for details.Custom color painted sprinklers may not retain their
The Model Fl FR56, F1 FR56LL, Fl FR42, F1 FR42LL, UL Corrosion resistance listing.Coverplate custom paint is semi-gloss,
unless specified otherwise.
Fl FRXLH and Model F1FR56, Fl FR56LL, Fl FR42, (2) cULus Listed only.
Fl FR42LL,Fl FRXLH&Fl FR28 Recessed Sprinklers should '3' 200°F(93°C)maximum.
be inspected quarterly and the sprinkler system maintained (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435
in accordance with NFPA 25. Do not cleans sprinklers with (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and
P RA1415(Pendent) in standard black or white. Corrosion resistance in
soap and water, ammonia or any other cleaning fluids. other polyester colors is available upon request.
Remove dust by using a soft brush or gentle vacuuming. '5) FM Approvals finish as"Polyester coated"applies to SIN Number
Remove any sprinkler which has been painted (other than RA1414,RA1435 and RA1425 in standard black or white.
factory applied) or damaged in any way. A stock of spare LPCBandVdSApprovedlinishappliesonytoRA1425,RA1414andRA1475.
Ordering Information
sprinklers should be maintained to allow quick replacement Specify:
of damaged or operated sprinklers. Prior to installation, 1. Sprinkler Model
sprinklers should be maintained in the original cartons and 2. Sprinkler Type
packaging to minimize the potential for damage to sprinklers 3. Orifice Size
that would cause improper operation or non-operation. 4. Deflector Type
Sprinkler Types 5. Temperature Rating
Standard Upright 6. Sprinkler Finish
Standard Pendent 7. Escutcheon Type
Conventional 8. Escutcheon Finish (where applicable)
Recessed Pendent 9. Cover plate Model
Vertical Sidewall 10. Cover plate Thread size
Horizontal Sidewall 11. Cover plate Temperature
Recessed Horizontal sidewall 12. Cover plate Adjustment
Concealed pendent 13. Cover plate Finish
Maximum Working Pressure Note:When Model F1FR56 Recessed sprinklers are ordered,the sprinklers
175 psi(12 bar) and escutcheons are packaged separately.
100% Factory tested hydrostatically to 500 psi(34.5 bar)
7.
Reliable. . . For Complete Protection
• Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers • Deluge valves
• Flush automatic sprinklers • Detector check valves
• Recessed automatic sprinklers • Check valves
• Concealed automatic sprinklers • Electrical system
• Adjustable automatic sprinklers • Sprinkler emergency cabinets
• Dry automatic sprinklers • Sprinkler wrenches
• Intermediate level sprinklers • Sprinkler escutcheons and guards
• Open sprinklers • Inspectors test connections
• Spray nozzles • Sight drains
• Alarm valves • Ball drips and drum drips
• Retarding chambers • Control valve seals
• Dry pipe valves • Air maintenance devices
• • Accelerators for dry pipe valves • Air compressors
• Mechanical sprinkler alarms • Pressure gauges
• Electrical sprinkler alarm switches • Identification signs
• Water flow detectors • Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory
Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries.
• Manufactured by
The Reliable Automatic Sprinkler Co.,Inc. ®
Recycled
(8 ) Sales Offices Paper
- Relable
IIWIdUII
(800)848-6051 Sales Fax Revision lines indicate updated or new data.
(914)829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.02/13 P/N 9999970300