Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
Zle 5 -- G.c� ` • • 1 rc,c' 90 74,i + + m�+ 72.00 �n n 49.00�n _Iffe_�,�Iyp� i 2.50 e 4 .375 DIA. I CONSTRUCTION:9WITCNBOAR018 BUILT AND LABELED PER UL BBt IN EFFECT. /S6 T INCOMING :ANPERE9:1200 2000 2300 • I I SERVICE :SYSTEM VOLTAGE:480Y/277 304W Wye AC 1-re„:.//I 23.00 28.00 I-2.1B I �j��� INTERRUPTING :THE SHORT CIRCUIT INTERRUPTING CAPABILITY IS 18,000 i Y t?� RESTRICE METRICAL AMPERES AT 440 VOLTS BASED ON THE LOWEST SHORT CIRCUIT TYPICAL BOLTDOWN RATING URRENT RAT NG OF THE NDIVID AL OR SERIES RA ED COMBINATION DEVICES NSTAI YYY _....1 AREA, 1 HOLE PROVISION FOR AT TIME OF MANUFACTURE OF BUSSING STRUCTURE.THE BUSSING STRUCTURE IS 2-$0 -•B• e k'• CUBICLE BOTTOM EACH CONSTRUCTED TO WITHSTAND FAULTS OF 86,000 RM8 SYMMETRICAL AMPERES. 4 CONDUIT CONDUIT SECTION ENCLOSURE ENCLOSURE 19 TYPE NEMA 3R FOR OUTDOOR APPLICATION. 11 25 11.125 Y LUG8 NG SEISMICENCLOSURE SHALL BE CONSTRUCTED TO MEET SEISMIC REQUIREMENTS Y 1 EXTERIOR ANSI 81 LIGHT GREY PAINT. -j LOAD LUGS TERMINATIONS :TERMINATIONS ARE ACCESSIBLE FROM THE FRONT. --BARRIER BUS BARS :TIN PLATED ALUMINUM BUS BARS SIZED ON BASIS OF 86•C MAXIMUM •- TEMPERATURE RISE. I, NEUTRAL BUS BARS :THE GROUND BUS IN THIS SWITCHBOARD IS Aluminum SIZED PER UL 881 OR CUBICLE DEPTH DISCONNECT GREATER. 11.125 ¢- - 7 LINK UTILITY :PORTLAND GEN ELEC Supply.1200 Supply.1200 (NOMINAL)Section.- Set0on.1200 �' SEE PLAN VIEW 4—i BONDING STRAP NAMEPLATE :NAMEPLATES ATTACHED WITH ADHESIVE. Neutral+- N.u4L.1200 I- UL_SUSE UL n CONCEALED 90.00'- � I" u HINGES a a a 7.5 ® a ® I I I 10.0 I I I I ROV SION CK 1.5 80.00'_ C I I 0 SEALING DEVICE RECEIVED CT COMPARTMENT NEUTRAL I I ®SEMS METER - 0 (PROVISION) 7.5 STANNDEVICE I 70.00'- 15.0 ®SEMI METER CV ©Et I FEB 12 2015 60.00'_ i -OCKE I I I I 17.5 I I I '15.0 SEE TABLE 10.0® 91.00 I WD0 CITY OF TIGARD 8.75 7 I I BUILDING DIVISION - 56 O 171] 70.00'- 250 UNUS. I I I D e SPACED I I ABBREVIATIONS 10.0 20.00'- SPACEUNUS. D I I I • 75.0 1.25 10A C I I I 10.00-- j.5 'UL'INDICATES 7MAT THE MARKED SWITCHBOARD SECTION COMPLIES WITH ALLAPPLICABLE 0.00 25.0 ® ® ® p 7.5 ® ® ® I UNDERWRITERS LABORATORIES STANARDS AND IS IDENTIFIED WITH A UL LABEL. 'SUS.INDICATES THAT THE MARKED SWITCHBOARD SECTION IS SUITABLE ONLY FOR USE SEC 35 00 1 I SECTIONS 2 I FRONT REAR AS SERVICE NCE EQUIPMENT. 'PROV'INDICATES TATT A PROVISION IS MADE FOR A FUTURE DEVICE. ALL REQUIRED MOUNTING HARDWARE IS PROVIDED. 'ONUS.SPACE INDICATES UNUSABLE SPACE NOT INTENDED FOR FUTURE USE. 'B'INDICATES A SERVICE BARRIER. BR o N LUGSANCH S 'P'INDICATES PADLOCK PROVISION. 1200 A AL UTILITY CO. INSTALLATION NOTE PER B&N PORTLAND GEN ELEC Caution;N switchboard Is Men In.blNd on•hou..Y..ping 1,200 A AL slab 8008185 Man 2.112' PER B l N _._ - - _ N.metro may be ever the .. •3'ma•Imum allowabI. __ DESCRIPTION--__T�---PO NO motor 1WOh1.Consult utility CT COMPARTMENT P322 II You need mere Information. OOPS 345 CT 1,200 A/3 r UNE TERMINATION PROVSION SOLID STATE 1\ N7 NN LSIG METER PLATES 332 SMM METERING 308 HO AD NN SUPPORT 310 NNYUI I ..mDS [ n o.ROGERS MACHINERY WHSE 3 Se-w 1,200 AAL • 5 PER08N r NORTH COAST ELECTRIC COMPANY 8 croyn•100 sxo,Loc MDP • Lv d °T0.018 M-No DED LUNN) J 1 0 0oyn8001 2+2015 Siemens Industry,Inc. � oe.nu croynX00c_02051501 01_00 000.20000.1 SECT( .er Loc OI BARRIER NO. REVISIONS DRAWN DATE BY: Nrocro..,080501. arum 1 002 CIRCUIT SCHEDULE !NUMBER DEVICE TRIP INTERRUPT METE 1 CT DESCRIPTION AMPERAGE(A) RATING(AIC) (POLES ACC !RATING LOAD LUG SIZE PER PHASE 1 NN 1,200 35000 3 _ _ _ I. 2 NN 900 25000 3 _ _ (3)500-750 KCMIL AUCU 3 JXD6 400 35000 r 3 _ _ _ 4 FXD6 250 35000 3 _ _ _ 5 6 FXD6 250 35000 3 1 1 I I I I ROGERS MACHINERY WHSE 3 -_ NORTH COAST ELECTRIC COMPANY SY c2Yns00c[K LOC otw.m .. MDP ` MDP I 34]015 Lac YANCLISUAKU NU 1 CO SECTION :1 OF 1I. PANEL TYPE :P5 4 CATALOG NUMBER :P5E75ML101ATS ENCLOSURE :1 Indoor • SYSTEM VOLTAGE :480Y/277 30 4W Wye AC IR RATING :18 K AIC MAIN BUS :1,000 A BUS MATERIAL Aluminum Tin FEED :Top MOUNTING :Surface SE LABEL :No SERIES RATED :No CONDUIT AREA :36.0 x 10.75 INDICATES POSITIONING NUMBERS TO HELP WITH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW PANELBOARD COMPONENTS I Main 1-1000A MAIN LUG MLO 1-(4)3/0.750Kcmil 1000A Branches: 1-70A/3P-NGB 1•100A/3P-NGB 1-150A/3P-FXD6 1-3P-FXD6-PROV T13 I : 2* 1-JD PROVISION 70A/3P 100A/3P 1-3PJXD6-PROV 41•900A/3P-NNX s ° 6 1-Non-Interchangeable Trip r Is 8 150A/3P Options: NM 9PROV 3P 10 F711410 1-Certification-UL s 12 1-Master NP Secured-Adhesive 11 u 14 1-NP Location•Trim 15 16 1-Card Holder-Std Plastic Sleeve 1-Std StI/AI Gnd Connector 17 13 18 19 20 21 nae 1s PROV 3P PROV 14 22 23 r 24 25 17 26 35.0 27 _ 28 29 30 31 19 32 75.0 33 34 35 900A/3P = 36 37 ,T38 39 40 41 11 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 12.75 Deep 38.0 ' ROGERS MACHINERY WHSE 3 • - NORTH COAST ELECTRIC COMPANY - R • 4400000Nwe euou.e 44. 0414 1000A MLO 244015 ' 1 0 croynx00c 2-6-2015 gyp croynx00c 02051501_01_00_000-21000-1 • • Portland General Electric Company 12/08/14 PG E CONTACT: Rogers Machinery Company Inc PHONE: 509-639-0808 CUSTOMER NAME: Frank Wiering ADDRESS: 14650 SW 72nd Ave SDPM/ENGR: Lee Martinez WR: M1457948 PHONE: 503-672-5483 3-PHASE SECONDARY LINE-LINE FAULT CURRENT (RMS) TRANSFORMER DATA PAD MOUNT? YES XFMR Impedance(%): 5.32 % 3-PH SUBMERS YES TRANSFORMER SIZE: 750 KVA XFMR? NO Secondary VOLTAGE(L to L): 480 v WYE OH BANK? NO VAULT--> VAULT ( or Pole --> Pole) SECONDARY Secondary Wire LENGTH: 20 Feet WIRE SIZE Number of SECONDARY RUNS: 3 Run(s)of: 350 OX UG Secondary WIRE Resistance R: 0.0600 Ohms/1000' Secondary WIRE Reactance X: 0.0330 Ohms/1000' VAULT ( or Pole) --> PANEL SECONDARY (or Svc Drop) Service Wire LENGTH: 1 Feet WIRE SIZE Number of Service RUNS: 1 Run(s)of: M Service WIRE Resistance R: 0.0180 Ohms/1000' • Service WIRE Reactance X: 0.0258 Ohms/1000' MAXIMUM FAULT CURRENT*: 16,468 Amps *Maximum fault current based upon transformers/conductors sized for 100% of electrical panel rating. Based on a panel size of: 800 Amps f , To Print This Page:"Ctrl M"and choose"Print 3-Phase Data" ' • • FRONT VIEW SIDE VIEW 23.9 25.0 •8.50 0.50" KEYHOLE SLOT(4) 8 17.00 8.00 2.00 X 3.00 28.75 TYPICAL PER SIDE 8 n `wJ 2.00 �--- 22.75 —� �--- 9.00 ---••1 0.56 DIA. (4) All Dimensions in inches ENCLOSURE COLOR : ANSI 61 GREY — OUTDOOR H.V.1. TERMINAL DETAIL L.V.1. TERMINAL DETAIL SUITABLE FOR 194-2 CU/AL SUITABLE FOR 250MCM-6 CU/AL CONDUCTORS CONDUCTORS 1 CONDUCTOR PER PHASE 1 CONDUCTOR PER PHASE CUSTOMER NOTES: — HV1 TERMINATED AT TOP FRONT — LV1 TERMINATED AT BOTTOM FRONT 0 0 0 REVISION DATE BY DATE BY CUSTOMER DRAWN 06/06/05 JW CHEK'D SIEMENS ORDER NO. DWG. NO. f VERIF'D 3F1 Y045TP1 SH 2 OF2 ° a , A m 5 1n P SIEMENS °< CATALOG NO. 3F1 Y045TP1 X2 A 2 A SERIAL NO. SERIES H H2 7J P1 > __, A 45 kVA 60 Hz 3 PHASE 6.6 % IMP AT 170 °C H, ,' 0mn _ 150 °C RISE °C AVG. AMBIENT H3 X1 X6 X3 HAM3008 N 220 °C TEMP CLASS °C MAX. AMBIENT VOLTS CONNECT PRIMARY ( H 1 H2 H3 ) 480V V 504 1 4 SECONDARY( X1 X2 X3 ) 240V V :i 492 2 480 3 g WINDING MATERIAL AL '' 468456 4 z ENCLOSURE TYPE NEMA-3R WEIGHT 370 LBS 444 5 6 ENERGY EFFICENCY NEMA TP 1-2002 432 7 0 vci SPACINGS BETWEEN ENCLOSURE AND ANY ADJACENT TYPE K 7, o WALL SHALL BE A MINIMUM OF 6 INCHES Z m X6 = 120V CT, 5% OF KVA RATING MAXIMUM da USTED O x1 'OSA*Eneryy CII) Rend nent° TRY TYPERendement TRANSFORMER LR 3902 En�s�°U�° liallPf E112313 77U5 r SUITABLE FOR INDOOR OR OUTDOOR LOCATIONS VEItIFIE BEFORE HANDLING, INSTALLING AND OPERATING, SEE INSTRUCTION MANUAL ! ' t w Z LNEIAA Class ANN Dry Type Transformer Siemens Energy & Automation, Inc Atlanta, GA U.S.A 0 -< 0 -a v VI- I 0 •', N 0.1 root 2007/09/06 10:04