Loading...
Report (51) 0,Q0 6/A) u7x-c{ .RECEIVEll MAY 2 7 2C!,; (11Y'0 � rt BoNAVENTUELDINGDIITivr,1 TIGARD 8325 SW Ross ST TIGARD OR FIRE ALARM DATASHEETS .. Prepared by Fire Systems West, Inc. Phone 360.693.9906 For Jet Industries 503.363.2334 4 Cm ! • - ? F e f • • _ Sa 8:25,SW Ross S: EE rot • .p.. T .A ' (. • _ _ .c` ica / `^ ,__ :,i - EEE • SCOPE OF WORK:New fire alarm system for assisted living facility. _ • SILENT ' KNIGHT IntelliKnight® Model 5820XL Addressable Fire Alarm Control System by Honeywell The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system,or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling • line circuit expander, 5824 serial/parallel printer interface I module (for printing system reports), and 5895XL intelligent • • power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum An Gentex®, Faraday, System Sensor, and Wheelock® charging capacity of c5 amp sours ( additional cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4)and Class A(Style 6)configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time f • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK(System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. P . . • - - •.•- • 1 • -V • . M IntelliKnight Model 5820XL • Addressable Fire Alarm Control Panel 1 . I I Indicator Lights 5820XL features a 6 amp power supply required to start a new system.The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure(PN RBB)is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite,which is Windows®- supervisory silenced be individually programmed to function based software. System Troubles(Yellow): Flashes as notification circuits,auxiliary power when a trouble condition exists;solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non- digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system has been silenced but not yet cleared twisted, unshielded cable when wired programming.The communicator has in compliance with standard wiring the ability to seize two telephone lines System Power(Green): Flashes for AC practices as called out in the National to report alarms and troubles to a • failure;solid when power systems are Electric Code 760-51 specifications for monitoring facility.The communicator • normal power-limited fire protective signalling supervises two phone lines and will cables. No special wiring is required. activate a trouble signal if a line failure System Application 5820XL provides 13 preset notification is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns(including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails,two phone devices dependent on protocol being for fire alarm notification. number capability,download phone used.Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing.The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally,the IntelliKnight system Contact ID.The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- multiple device types, including: programming. Its innovative, dead-front account number. • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector User Interface • Addressable heat sensor The 5820XL built-in annunciator with a _ _ . • Addressable duct smoke detector 80 character LCD display and large .-.r " '" 0 • Contact module easy-to-use tactile touchpad can be " '' It 't "4 G • Relay output module used for system operation, a �� programming and maintenance. It has R .0 • Addressable notification module five LEDs for alarm,supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power.System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, - alarm troubles and memory.The NFPA 72:Central Station; Remote • • Addressable multi modules(SK system's non-volatile event history protocol only) buffer stores 1000 events for viewing Signalling; Local Protective Signalling from the built-in or remote annunciator. Systems;Auxiliary Protected Premises The following advanced sensor Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual,waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; ' NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming.The JumpStart®feature MEA 429-92-E Vol.VI; FM Approved minimizes programming e • t - .w•- , IP • -. . . I I . M IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL """Fad A'' Addressable Fire Alarm System tAoneyemmlt so4wer` SK(System Sensor) Protocol Devices Wndnvs Based Uprpovtnload Sc to 1 _.......,... M Conlpatbt'CS p'�" - Receival AutomaCOn SOflvere • WM A Internet 5820XL SK-212UD Connection VicorAlarm IP Commuricator I 5615XL I. ------IP Inueoe Po.wrlruauR i 4 !Rya C away. 4 • • Pale _ _ 5115XL 4I R&M st e,oa+arr 5860 5824 kemok?mur,eeor Ara4Ga.ra,•Mitua a Reoccur" 0Mac Srseml �..e - 5 6 Rur" ��. \ . BO drub5315XL f can be inputs SIC>'.srsmY_- W Qmtpm n e Flexpee y I IOChWts i 6 6I can ba Inputs oto ; Ed ri ,1 -, 1 4 ,]..,,,,,I:/:.nllanfirm asap': { 111* Fla® [vFttaona %. nM sows oaenan TV zi: ....,__::: . 8K4on SK4i n tor SK4so SK•Cont ol•6 Se Control 13200SR Bit Acclimate SKZone-a Fdtr.srarte AMe<4e&]e Fard lsr&Lr A]soaooMc 'U,..enceat I.lultnl.wa Zone G'xa'H02. M ntu M_Nlxu II.f4rgfei 0.4W Bzse .IIAV in«teru 5880 Dxta.YS t:Mie ...We M.vuW alert.- Motto Remote/a-alnuelr. 1111111'. Of r'f- 77 iii SK-Photo 8K•INoN[or-2 Skitdaymon-2 OLtreat 822488 822481 B210LP i CK-Photo-T Du/Monier tnaraae pC.Kea1ROR ..rani wax ctn.,- 3880 rWdeultie hbL1W pae %Aar SKa1nt•MT He1:15,tRuffse e e, LEO 00rerS thaoJYLm i is Fear hW.NsaNs �Millumim I:dModule Dolttla ex ai ue cm$ -I * t * I 1 I# Oar 7 '': • I I 1_ ilii &JAI Pri.iir 1 l I I I 5883 I Rehm ln191fs2 Molds 4 8K-Buell SKRl00.10 BKArU.DA 6K Puc1 SK411nlmon 13KRelay-8 SK-Zane fes-n BKaeem•T Mkt,,,,,", oC Pull-6A Amessatla uKnlo, Pay-Control Add%iatlo Ad*cc... .o hdr,m,.. Monter Adder abe Dun KAule Mniuk imertrc-e Fiioy Baan Daleaci Abdo% Ful Sta)on DReW w,.va WWI. EU- . I -. 5865-4 or 5865-3 I Use ale 5860 to control up to 4 I _, 1`ID�.05a yluxnj `5803 Relay Interface Modules i 111,' 411 • • • i• - •.•- r . • . . • IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite • Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz,2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using !� and 5860R is red. a PC.Upload and view panel account Total Accessory Load: 6A @ 27.4 VDC, power-limited 5815XL Signal Line Circuit Expander information, event history,and detector Standby Current:215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system.5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power,6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/IO Module 16"W x 10"H x 6"D 14.5'W x 24.75"H x 3.9"D Features 40 LED outputs,8 normally (406 mm W x 254 mm H x 152 mm D) • (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR.Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED(15 of detector alarm. red and 15 yellow)outputs,and a piezo SD and SK Devices • Weight:28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events,detector status Type of Jack: RJ31X(two required) reports,and event history. Interfaces with building control system. c This document is not intended to be used for installation purposes.We try to keep our SILENT product information up-lobate and accurate.We cannot cover all specific applications Made in America KNIGHT or anticipate all requirements.All specifications aresubject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight •- yr SILENT 5499 Distributed KNIGHT Power Module , 00 by Honeywell The NAC expander that packs quite a . combination punch, a whopping nine amps . and built-in synchronization for appliances The 5499 Distributed Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 9 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,AMSECO, Faraday, Gentex®, and Wheelock®—what you need to drive power-hungry components like ADA notification appliances.The 5499's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5499 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5499. Call Silent Knight today for more information at 1-800-328-0103. • Description • Ground fault detector/indicator The 5499 is a 9 amp notification power •• Independent trouble relay expander that provides its own AC • AC loss delay option shuts off power power connection, battery charging to non-essential high-current circuit,and backup battery for use with accessories like magnetic door holders fire and security controls that have 9-32 , Stand alone operation. VDC outputs, such as the Silent Knight Model 5208 Fire Control/Communicator. • Lightweight design adds to ease of installation and reduces shipping The 5499 is the cost-effective solution costs for powering notification appliances • Operates with most polarized, UL required by the Americans with Listed notification devices Disabilities Act(ADA).The 5499 has • ANSI Cadence pattern output built-in ANSI cadence pattern,which capability built-in can upgrade older control panels that Connection to Local Fire Control ` ;I;�,.'� lack cadence capability. Firepower 5499 may be connected to a Features local fire control which utilizes Class A 5499 • UL Listed for 9 amps of notification or Class B type notification circuits Supervision power operating between 9 and 32 VDC.The The 5499 supervises a variety of • Built-in synchronization for appliances control panel's notification circuit is functions including: from System Sensor®,AMSECO, connected to one of the inputs on the • Low AC power. Faraday, Gentex®, and Wheelock® 5499.The controlanel's notification • Power supply's advanced switch p • Low battery condition. circuit end-of-line resistor is also mode design reduces damaging heat • Earth ground fault. and manages power up to 50%more connected across two terminals on the • Auxiliary output power limit condition. efficiently than other systems Firepower 5499,which provides • Dip switches allow for easy supervision between the 5499 and the ' EOL supervision trouble or power reconfiguration fire control panel. Polarized audible limited condition at an output. • • 24 VDC filtered output voltage and/or visual notification devices are When a trouble condition occurs, • F• Four power-limited notification then connected to the 5499 signal condition on on5the hostcreacontroles a troubleig outputs; 2 Class A(Style Z)or 4 condition host signal P ( Y circuits using the 4.7kW end-of-line circuits to which it is connected. Class B(Style Y), resistorsprovided.Since the 5499 or 1 Class A and 2 Class B Firepower 5499 still maintains the • Additional continuous auxiliary output draws very little power from the control, ability to be activated by the host it is possible to connect one Firepower control.In addition,the 5499 provides a • 3 amps per output circuit 5499 to each notification circuit on the Form C trouble relay output as an • 2 inputs;2 Class B Style B) control panel and still provide full alternative to using the notification or 2 Class A(Style ) supervision of the notification circuits all circuit trouble. the way back to the control panel. Model 5499 Distributed Power Module Model 5499 Block Diagram Signal Circuit Output Signal 1 Signal 1 • nput Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Signal 3 Module 5499 (Optional) Signal 4 120 VAC Aux. Power • I Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Electrical Specifications Mechanical Specifications Ordering Information AC Input: 120 VAC at 3.0A Dimensions: 12.25"W x 16"H x 3" D 5499 Distributed Power Module Output:24 VDC at 9 A 30.88 cm W x 40.64 cm H x 7.62 D cm Accessories: Current Operating Temp: SK-SCK Seismic Compliance Kit Standby: 75 mA 32°to 120°F(0°to 49°C) Alarm: 205 mA Humidity:93% non-condensing max. Auxiliary Power Circuit: 1 Indicator Lights Notification Circuits:4 AC power on: Green Output Configuration: Battery trouble: Yellow 2 Class A(Style Z) Ground fault: Yellow • 4 Class B(Style Y) Aux Trouble: Yellow (1 Class A&2 Class B) Amps Per Output: 3.0(9.0 amps total) Output troubles(1-4): Yellow Notification Circuit Output: 20.4 to 27.3 VDC @ 3.0 amps each,4.7 kCl EOL Installation resistor required on each Class B Surface mount • circuit Approvals - No. of Inputs: 2 • NFPA 72 Input Configuration:2 Class B (Style Y) • UL Listed or 2 Class A(Style Z) • CSFM 7300-0559: 123 Input Voltage Range:9-32 VDC ' MEA 429-92-E Vol.XII • OSHPD(CA)OSP-0065-10 Battery charging Capacity:35.0 AH (see accessories) • SILElENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350396 Rev F ® subject to change without notice.For more Information,contact Silent ®2013 Honeywell International Inc by Honeywell Knight 7550 Meridian Circle Suite 100,Maple Grove,Mn 55369-4927. Phone:(800)328-0103 or(203)484-7161,Fax:(203)484-7118.For Techinicat Support,Please call 800-446-6444. www.silentknight.com tSILENT 5860 Remote Annunciator rIII KNIGHT o by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. • Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator.The 80-character display and ergonomically designed keypad allow for simple and • error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions.The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call • 1-800-328-0103. • Description multiple 5860s Features include an 80-character • RS-485 interface to panel backlit LCD providing easy-to- • Operation and appearance is _ � : understand system messages.The identical to 5860 built-in �'�`�'"` annunciator is ergonomically annunciator designed with over-sized buttons • On-board piezo sounder audibly .... . for the most frequently used indicates alarms, troubles, and l; features, like Reset and Silence. supervisones , , • In addition to status messages ' Five status LEDs for alarm, '.,--7- __ , supervisory, trouble, silence and displayed on the LCD, there are AC power conditions - five LEDs for alarm, supervisory, • Wiring lengths up to 6000 ft.from trouble, silence, and AC power the FACP(depending on wire status. gauge and number of devices on 5860 The annunciator is available in gray SBUS) Environmental to match virtuall anydecor and • UL listed, complies with NFPA 72 Operating Temperature: 32°F– y120°F (0°C–49°C red for applications where the • CSFM approved 49°C) annunciator must stand out.The Electrical Specifications Humidity: 10%–93% non- annunciator enclosure can be Operating Voltage: 24 VDC condensing surface or flush mounted.A trim Standby Current: 20 mA max Compatibility ring kit is available for surface with the mounting. The 5860 is Alarm Current: 25 mAcompatible following FACP's: Wiring Distance:6,000 max. from Features FACP(depending on wire gauge • 5820XL Addressable Fire Control - • 80-character backlit LCD display and number of devices on the Panel (4 lines with 20 characters on SBUS) • 5820XL-EVS FACP with each line) Emergency Voice System • Tactile and audible feedback Max Per System: 8 • 5808 Addressable Fire Control • Accepts user codes or fire Mechanical Specifications Panel fighter's key Physical 9.1"W x 7.4" H x 1.5"D . 5700 Addressable Fire Control • • Larger keypad buttons for system (23.1 W x 18.8 H x 3.8 D cm) Panel reset and silence Shipping Weight: 2.8 lbs (1.3 kg) Listings • Install up to eight 5860s per FACP Color NFPA 72; UL Listed; • Available in red or light gray 5860R: Red CSFM 7170-0559: 135; • Support for simultaneous use of 5860: Gray MEA 429-92-E Vol. IX; FM Approved 419 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of.040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator - keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals.The control panel must allow all annunciators to accommodate multiple user input simultaneously. • Wire*gni.0 t hem MCP IOU VW sPer Syst re leltioluilible OM FAgP Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. It SILENTThis document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350224 Rev F subject to change without notice.For more information,contact Silent Knight ®2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610.Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. www.silentknight.com iNTELLIKNIGHT ACCESSOR SILENT SK-Photo, SK-Photo-T NI KNIGHT and SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor®PN RA100Z) SK-Photo and SK-Photo-T are plug-in • Plug-in mounting provides ease of type smoke sensors that combine a installation ...--.-.-z.-_-,, -- photoelectric sensing chamber with • Tamper-proof feature available on - addressable analog communications. mounting bases 'WAIL Point ID capability allows each � 1 detector's address to be set with rotary • Listed for use in duct applications ti - 1. I address switches, providing exact • Rotary address switches for fast detector locations for selective installation J , maintenance when chamber • UL Listed � - contamination reaches unacceptable • FM Approved .`rr�� - i? levels. .° r 4 r• Specifications � : `' SK-Photo and SK-Photo-T have a -' ` unique optical sensing chamber that is Physical engineered to sense smoke produced Height:2.0"(5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1"(10.4 cm)installed in sources.In the SK-Photo-T, dual B501 base electronic thermistors add 135°F(57°C) • Installation thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300µA @ 24 VDC Maximum P remote test capable detector head DNR/DNRW duct smoke detector.(not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct • included) (with LED on) smoke detector. Environmental Operating Temperature Compatibility Features SK-Photo:32°-120°F ° 0°C-49C (0°C 49°C) SK-Photo,and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°-100°F(0°C-38°C) compatible with the following detector • Base included Humidity: 10%-93% non-condensing bases: • Reliable analog communications for Other Ratings B210LP 6"base(included) B501 2 wire base trouble-free operation SK-Photo-T Thermal: Fixed B224RB Relay base • Age resistant polymer housing temperature set point 135°F(57°C) B224B1 Isolator base • Dual electronic thermistor design on Velocity:0-4000#pm(0-20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS • • any application 5808 _ 5700 • Dual LED indicators for 360°visibility 5600(Rev 2.0 or higher) • • Detector transmits signal to indicate maintenance is required - Model SK-Photo, SK-Photo-T and SK-PhotoR - Intelligent Photoelectric Smoke Sensors Engineering Specifications . The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal.The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W)duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision.When the detector is actuated, the flashing LED will latch on steady.The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector.The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. •-. ',. ., � ,50.74"-: Compatible FACP �I..Y'•�1:.- ` yyam�..,, RA100Z(Optional) + - (--------1:77iiiii ,,74. I. :el w. • -ram �� I �".. - LIIHIN 2 . IF(1- Y1/41:0i ; %.0 10 1 ? i ! -..i ...___Class A Optional Meng Wiring SK-Series Detector Mounting Bases • it SILENT This document is not intended to be used for Installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E a subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. . www.silentknight.com SILENT SK-Pull-SA and SK-Pull-DA KNIGHT Intelligent Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only I R one motion to activate the station.The SK-Pull-DA is a dual E action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight 1 PULL 4 Uo Intelliknight series fire-alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition ,,,I,T1.1 • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locksF 1 „I-1i'. Fe.• • • Meets the Americans with Disabilities Act Accessibility . Guidelines (ADAAG) controls and operating mechanisms # PUSH IN guidelines (Section 4.1.3[13]) • PULL DOWN • Meets ADA requirement for 5 lbs maximum pull force to `�-��--a.. �r active • Shell, door, and handle molded from durable LEXAN® ° i;f-; '!La\ {p6 h..1(.11: ^3 k • Reliable analog communications for trouble-free operation ._ „ ; • Braille text on station handle SK-Pull-DA .. • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • • Rotary address switches for fast installation with the following IntelliKnight FACP's: • 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS r\ Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. - TT massA...-_-._.....__._ • -_. Cass B Compatible FACP i- =r'`i c ";1: l21i � Lar '� 5'lk J 'JAY }`' 9 4 r{• FyG��yr -q ..`� r=xf ;474,7, R. t 1. Class A NArM9:."—"_. Class B NAdnp: Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4"(10.2 cm) Wire Gauge: Up to 12 AWG(3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°--120°F(0°C—49°C) Bi-Colored LED: Humidity: 10%—93%non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/0) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox • SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent FORM#350135 Rev C • Knight 12 Clintonville Road,Northford,CT 06472-1610 ®2013 Honeywell International Inc. by Honeywell Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com l SILENT SK-Monitor KNIGHT by Honeywell Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs).The SK-Monitor is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. . jw The SK-Monitor supports Class A supervised or Class B `^► supervised wiring to the load device. Conventional 4-wire • _ smoke detectors can be monitored for alarm and trouble conditions. r a� * n `�_ Features E-P � , • Single contact monitor • Support for Class A and Class B wiring , ` ' 5 • Fully supervised14-„� t i • Panel controlled status LED that flashes green in � r zT normal state and is solid red in alarm • Attractive ivory cover plate SK-Monitor • Rotary address switches for fast installation • SEMS screws for easy wiring Specifications • UL Listed Physical Installation Height:4.5" (11.4 cm) The SK-Monitor mounts directly into a 4"square electrical Width: 4" (10.2 cm) box.The box must have a minimum depth of 2-1/8".A Depth: 1.25" (3 cm) surface mount electrical box(System Sensor®PN Shipping Weight: 6.3 oz(196 g) SMB500) is available from Silent Knight. Electrical Compatibility Operating Voltage: 15—32 VDC The SK-Monitor is compatible with the following Current Draw(LED on): 5.0 mA max IntelliKnight FACP's: Operating Current(LED flashing): 375 pA 5700 5808 5820XL 5820XL-EVS •-• SILENT SK-Relay KNIGHT Intelligent RelayModule by Honeywell 9 The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command.The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. , • The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the Installation SK-Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square Features electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2-1/8".A surface mount electrical box (System Sensors PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility • • Panel controlled status LED that flashes green in normal The SK-Relay is compatible with the following IntelliKnight FACP's: ▪ state and is solid red in alarm 5820XL • Relay programming is completely flexible-can be mapped 5820XL-EVS to zone conditions 5808 5700 • Polling LED visible through the cover plate 5600 (Rev 2.0 or higher) • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed Model SK-Relay Intelligent Relay Module To Next Device 1 If Any Wiring to Terminals 3—9 is Not Power + Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, n n Which Must Be Placed Over the Power Limited . '0 D c O 1_Dt_i Terminal Information on the Name Plate Label. Relay Common 2 1 ;,! ..o. 0 ■I Normally Closed 2 €:i a 1 •6 + Normally Open 2 ' 2'7 2 1=t; I Relay Common 1 i • of-, a — From Compatible FACP Normally Closed 1 ;: a , j 4 + or Previous Device _ Module Does Not Supervise n1 lrJ� Normally Open 1 _ Controlled Circuits v o v U U Wiring the SK-Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA(with LED latched on) Depth: 1.1" SLC Loop Resistance:4052 max. Shipping Weight: 6.3 oz(196 g) Relay Contact Ratings Electrical 3.0A @ 30 VDC resistive • Operating Voltage: 15—32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current: 0.5A @ 125 VAC inductive (PF = .35) 230 pA(LED flashing) direct poll 0.7A @ 75 VAC inductive (PF = .35) - 255 pA(LED flashing)group poll SILENTEl This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350127 Rev D ® subject to change without notice.For more information,contactr Silent • by Honeywell Knight 12 Clintonville Road,Northford,CT 06472-1610 Phone: ®2013 Honeywell International Inc. • (800)328-0103,Fax:(203)484-7118.For Technical Support,Please Call 800-446-6444. www.silentknight.com - INTELLIKNIGHT ACCESSORY ftSILENT SK-Heat, SK-Heat-HT 4KNIGHT and SK-Heat-ROR by Honeywell Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors,with integral communication,that provide features that surpass conventional detectors.These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels(FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation.The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description visibility SK-Heat, SK-Heat-HT and SK- • Detector transmits signal to Heat-ROR are intelligent sensors indicate maintenance is requiredj,.:_ that utilize a state-of-the art • Plug-in mounting provides ease .. thermistor sensing circuit for fast of installation .- _ response. Sensitivity is • Optional remote LED annunciator • continuously monitored and (System Sensor®PN RA100Z) reported to the FACP. Point ID capability allows each detector's • Tamper-proof feature available on - address to be set with rotary mounting bases address switches, providing exact • Rotary address switches for fast SK-Heat(base included) detector locations for selective installation SK-Heat-HT: High temperature heat maintenance when chamber • UL Listed sensor 135°F- 190°F(57°C-88°C) • contamination reaches unacceptable levels. Specifications SK-Heat-ROR: Rate-of-rise SK-Heat is a fixed temperature Physical detection 15°F/min (8.3°C/min) sensor that uses a thermistor Height 2.0" (51 mm) Compatibility . • sensing circuit to produce 135°F Diameter:6.1" (155 mm)installed (57°C)fixed temperature alarm. in B210LP base The SK-Heat-HT and SK-Heat- Shipping Weight: 4.8 oz(137 g) ROR are compatible with the SK-Heat-HT is a variable high following IntelliKnight FACP's: temperature detector that provides Electrical high temperature detection at Operating Voltage: 5820XL • 135°F- 190°F. (57°C-88°C) 15 to 32 Volts DC Peak 5808 SK-Heat-ROR is a rate-of-rise Standby Current: 5700 • temperature sensor with 135°F 300pA @ 24 VDC The SK-Heat is compatible with the (57°C)fixed temperature alarm. LED Current: 6.5 mA@ 24 VDC following IntelliKnight FACP's: Features Environmental 5820XL 5808 • Reliable analog communications Operating Temperature 5700 for trouble-free operation SK-Heat&SK-Heat-ROR: 5600 (Rev 2.0 or higher) -4°— 100°F (-20°C—38°C) - • Age resistant polymer housing The SK-Heat, SK-Heat-HT and SK- • innovative thermistor sensing SK-Heat-HT -4°—150°F Heat-ROR are compatible with the circuit (-20°C—66°C) following detector bases: • Superior EMI resistance for Humidity: 10%—93% B210LP 6"base (included) reliability noncondensing B501 2 wire base • Variety of mounting options to Thermal Ratings 622461 Isolator base meet any application SK-Heat: Fixed temperature alarm B224RB Relay base • Dual LED indicators for 360° 135°F(57°C) B200SR Sounder base . - INTELLIKNIGHTACCESSORY w r Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR.The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated,the flashing LED will latch on steady at full brilliance.The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing.The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. •1 - oke = .i. - t: ek_.,ir + �t M'..0 e d C•n v°'4 .;?', 1,1Compatible FACP RA100Z(Optional) t _.IMIM .. i 3 ! , i I rIN isi. /IN ? -;,-; pi � �r = \NJ" �J i ii M ■ / i Y—......_._..�....... ClauA OptionalWiring ...i .....................»...... Wiring SK-Serlea Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle. RA1002-Remote LED Annunciator. XP-4-Extension Pole for XR2B.Extends from 5—15 ft. RMK400-Recessed Mounting Kit.Provides low profile for use with T55-127-000-Detector Removal Head. B501. XR2B-Detector Removal Tool.A removal and re-placement tool BCK-2008-Black Detector Kit.For SK series detectors. for SK plug-in detectors.Includes the T55-127-000. 'Unless otherwise noted,specifications apply to all SK thermal . M02-04-01-Replacement Test Magnet. detectors. 0 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject FORM#350120 Rev.D1 to change without notice.For more information,contact Silent Knight 12 p 2013 Honeywell International Inc. by Honeywell Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support call 800-446-6444. www.slientknight.com INTELLIKNIGHT ACCESSORY i• SILENT SK-Fire-CO KNIGHT fo Advanced Combination by Honeywell Fire and CO Detector SK-Fire-CO offers world-class fire and carbon monoxide(CO)detection combined in a single addressable device to provide a practical and cost-effective solution for today's market. For more information about the SK-Fire-CO,or to locate you nearest source, please call-800-328-0103. SK-FIRE-CO The SK-Fire-CO is a plug-in,addressable device that provides both fire and carbon monoxide (CO)detection. For • fire, the detector combines four separate sensing elements in one unit(smoke, CO, light/flame, and heat)to sense • ry�' E`� multiple components of a fire.This approach enables ^=_ enhanced sensitivity to real fire with heightened immunity to • nuisance particulate. For CO,the detector's electrochemical • sensing cell creates a separate signal for life safety CO detection. - - -Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses.Because the S potential exists for dangerous levels of CO to accumulate in - almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada.The SK-Fire-CO is listed to SK-Fire-CO installed in a the UL 2075 standard for system-connected life safety B200S Sounder Base(sold separately) carbon monoxide monitoring. The SK-Fire-CO should be used in conjunction with the • RealTest®CO testing capability B200S intelligent sounder base(sold separately),which can • UL 268 and UL 2075 listed generate either a Temp 3 pattern for fire or a Temp 4 •Separates audible signal for fire or CO alarm • pattern for CO alarm indication.With each sounder base when used with the B200S base learning the address of the detector connected, the FACP • CO cell end-of-life warning and fault can then command an individual sounder,or a group of sounders, to activate.The command set from the panel can Compatibility be tailored to the specific event, allowing selection of tone, The SK-Fire-CO is compatible with the following and group. For more information on the B200S refer to Data IntelliKnight FACP's programmed for System Sheet P/N 351183. Sensor protocol: (Firmware version 13.0 or SK-Fire-CO can also be used with the B21OLP 6•standard higher). base,the B200SR sounder base or the B224RB relay base. • 5700 ' Features • 5808 • 5820XL • Unique ability to detect all four major elements of a fire: • 5820XL-EVS -Smoke -Carbon Monoxide(CO) -Light/flame -Heat • •Separate CO detection signal • Highest nuisance alarm immunity •Automatic drift compensation of smoke sensor and CO cell • Uses only one address on the SLC e Model SK-Fire-CO Combination Fire and CO Detector Specifications Ordering Information Physical SK-Fire-CO Combination Fire and CO Detector Diameter: 6.875" (17.46 cm)installed in a (base not included) B200S base Height: 3.46"(8.79 cm)installed in Optional Accessories B200S base B200S Intelligent sounder base Shipping Weight: 4.6 oz B210LP 6"mounting base Color: Ivory B200SR Sounder base B224RB Relay base Operating M02-04-01 Detector test magnet Temperature Range: 32° F to 100° F(0° C to 38° C) M02-09-01 Telescoping test magnet Humidity: 15 to 90% relative humidity (non-condensing) - Air Velocity: 0 to 4,000 ft/min(0 to 20 m/sec) Electrical . Operating Voltage: 15 to 32 VDC Maximum Standby: 300pA at 24 VDC(no communication every 5 seconds with LED blink enabled) Maximum Alarm Current(LED on): 7.2 mA at 24 VDC CO Monitoring UL Standard Reference-Alarm Thresholds are as follows: Parts Per Million - Detector Response Time . 70±5 ppm 60-240 min. 150±5 ppm 10-50 min. 400± 10 ppm 4-15 min. Note: Per UL Standard 2075,the SK-Fire-CO has been tested to the sensitivity limits defined in UL Standard • 2034. SILENTN itik This document is not intended to be used for installation purposes.We try to Assembled In America keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#351181 Rev D • subject to change without notice.For more information,contact Silent Knight 2014 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford.CT 06 472-1 61 0 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. www.silentknlghtcom