Loading...
Report OPP SAO/ 6002._ S-75—z SCJ Ktirrs, V/2-w, %TM' 30, 2 9 7015 . 41 • • • • • • No W YAT , FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 SOUTHVIEW HEIGHTS LOT 6 15152 SW HARVEY'S VIEW AVENUE TIGARD, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL tqcoWorldwide Fire Protection Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has Description been designed with heat sensitivity and water distribution characteristics : TYCO RAPID RESPONSE Series LFII proven to help in the control of residen- Residential 4.9K Concealed Pendent tial fires and to improve the chance for Sprinklers (TY3596) are decorative, occupants to escape or be evacuated. fast response,fusible solder sprinklers The Series LFII Residential Con- designed for use in residential occu- cealed Pendent Sprinklers (TY3596) .. pancies such as homes, apartments, are shipped with a Disposable Pro- 00°'. „,,,,,.:;,:n...77.,:17:-..---, dormitories,and hotels. tective Cap. The Protective Cap is a =_ v The cover plate assembly conceals temporarily removed for installation, the sprinkler operating components and then it can be replaced to help above the ceiling.The flat profile of the Protect the sprinkler while the ceiling NOTICE cover plate provides the optimum aes- is being installed or finished.The tip of thetically appealing sprinkler design. the Protective Cap can also be used The Series LFII Residential Concealed In addition, the concealed design of to mark the center of the ceiling hole Pendent Sprinklers(TY3596)described the Series LFII Residential Concealed into plaster board, ceiling tiles, etc. herein must be installed and main- Pendent Sprinklers(TY3596) provides by gently pushing the ceiling product tained in compliance with this docu- 1/2 inch(12,7 mm)vertical adjustment. against the Protective Cap.When the ment and with the applicable standards This adjustment provides a measure of ceiling installation is complete the Pro- of the National Fire Protection Associa- flexibility when cutting fixed sprinkler tective Cap is removed and the Cover tion(NFPA),in addition to the standards drops. Plate Assembly installed. of any authorities having jurisdiction. The Series LFII Residential Concealed Dry Pipe System Application Failuso may impair the perfor- mance mancce e of tth ohese devices. Sprinklers are intended for use in the The Series LFII Residential Concealed following scenarios: Pendent Sprinklers offers a laboratory The owner is responsible for main- approved option for designing dry pipe taming their fire protection system • wet and dry pipe residential sprin- residential sprinkler systems,whereas, and devices in proper operating con- kler systems for one-and two-fam- most residential sprinklers are labora- dition. Contact the installing contrar- ily dwellings and mobile homes per tory approved for wet systems only. tor or product manufacturer with any NFPA 13D Through extensive testing, it has been questions. • wet and dry pipe residential sprinkler determined that the number of design' systems for residential occupancies sprinklers (hydraulic design area) for Sprinkler up to and including four stories in the Series LFII Residential Concealed height per NFPA 13R Pendent Sprinklers (TY3596) need Identification • wet and dry pipe sprinkler systems not be increased over the number of for the residential portions of any design sprinklers (hydraulic design Number (SIN) occupancy per NFPA 13 area)as specified for wet pipe sprinkler systems,as is accustomed for density/ TY3596 area sprinkler systems designed per NFPA 13. Consequently,the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in . IMPORTANT addition to not having to increase the Always refer to Technical Data number of design sprinklers(hydraulic Sheet TFP700 for the "INSTALLER design area) for systems designed to WARNING”that provides cautions NFPA 13, 13D, or 13R. with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 FEBRUARY 2015 TFP442 TFP442 Page 2 of 6 BODY l p SEALING WRENCH (1/2" NPT) ASSEMBLY RECESS CAP 1 ����''\ //' �� l� /� SPRINKLER It I /`���� WRENCHING SADDLE i - \� „ AREA 1 I COMPRESSIONPUSH WRENCH SUPPORT I- IN ENGORENSURE GEMENT CUP WITH ( I SCREW ROLL FORMED i WITH SPRINKLER THREADS - IL__ -iia LEVER WRENCHING AREA FIGURE 2 DDI) W-TYPE 18 GUIDE 1I SPRINKLER WRENCH PIN ' m SOLDER LINK ELEMENT GUIDE PIN HOUSING DEFLECTOR 1 � (OPERATED DEFLECTOR - r POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO I I RETAINER SUPPORT I i WITH THREAD CUP UNTIL J IDIMPLES MOUNTING �� 0 0 ) SURFACE IS FLUSH WITH CEILING EJECTION SPRING SOLDER 7-J COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) 2-1/2" DIA. SPRINKLER- + (63,5 mm) 1 1/2"(12,7 mm) FACE OF SUPPORT CUP 1/2" / THREADED SPRINKLER ASSEMBLY NPT 1--- -71-1 ---Ill' ADJUSTMENT FITTING ' OPERATED SPRINKLER 1 7/8"±1/4" COVER lif. - (47,6 mm vimlik PLATE 1/8"GAP ±6,4 mm) RETAINER lulu (3,2 mm) Ii---- _p_a -lr. * \ .. ..lams . , -- COVER- SPRINKLER- 7/8 (22,2 mm) RETAINER SUPPORT CUP MOUNTING 1-1/8"(28,6 mm)ASSEMBLY ASSEMBLY 3/16" SURFACE Oil _ _� (4,8 mm) \ 1 3-3/16" DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) -� TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Design Criteria Dry Pipe System Water Delivery When using the Series LFII Residen- Data TYCO RAPID RESPONSE Series LFII tial Concealed Pendent Sprinklers - Residential Concealed Pendent Sprin- (TY3596)in dry pipe sprinkler systems, Sprin- the time for water deliverymust not Approvals klers(TY3596)are UL and C-UL Listed exceed 15 seconds for the ost remote UL and C-UL Listed for installation in accordance with this NYC Approved under MEA 44-03-E-2NSF section, operating sprinkler. Certified to NSF/ANSI 61 Obstruction to The TYCO RAPID RESPONSE Series LFII Note: When conditions exist that are Water Distribution Residential Concealed Pendent Sprinklers outside the scope of the provided cri- S rinklers are to be located in accor- are only Listed with the Series LFII Con- teria, refer to the Residential Sprinkler dance with the obstruction rules of cealed Cover Plates having a factory-ap- Design Guide TFP490 for the manu- plied finish. facturer's recommendations that may NFPA 13D, 13R, and 13 as applicable Cover Plates can be ordered by following be acceptable to the authority having for residential sprinklers as well as with the instructions in the Ordering Procedure jurisdiction. the obstruction criteria described within section. the Technical Data Sheet TFP490. Maximum Working Pressure System Types Operational Sensitivity 175 psi(12,1 bar) Per the UL Listing, wet pipe and dry y pipe systems may be utilized. Per the The sprinklers are to be installed rela- Discharge C fficient C-UL Listing, only wet pipe systems tive to the ceiling mounting surface as K=4.9 gpm/psi"`(70,6 Ipm/bar112) may be utilized. shown in Figure 3. Temperature Rating Refer to Technical Data Sheet TFP485 Sprinkler Spacing 160°F(71°C)Sprinkler with about the use of residential sprinklers in The minimum spacing between sprin- 139'F(59°C)Cover Plate residential dry pipe systems. klers is 8 feet (2,4 m). The maximum Vertical Adjustment spacing between sprinklers cannot 1/2 inch(12,7 mm) Ceiling Types Smooth flat horizontal, or beamed, or exceed the length of the coverage area Finishes sloped, in accordance with the 2013 (Ref. Table A or B) being hydraulically Refer to Ordering Procedure section. Edition of NFPA 13D, 13R, or 13 as calculated(e.g.,maximum 12 feet for a Physical Characteristics applicable. 12 ft.x 12 ft.coverage area,or 20 feet Body Brass for a 20 ft.x 20 ft.coverage area). Cap Bronze Hydraulic Design The Series LFII must not be used Saddle Brass (NFPA 13D and 13R) in applications where the air pres- Sealing Assembly Beryllium Nickel For systems designed to NFPA 13D sure above the ceiling is greater than w/TEFLON or NFPA 13R, the minimum required that below. Down drafts through the Soldered Link Halves Nickel sprinkler flow rates are given in g Lever Bronze Tables A and B as a function of tern- Support Cup could delay sprinkler Compression Screw Brass perature rating and the maximum operation in a fire situation. Deflector Copper or allowable coverage areas. The Brass sprinkler flow rate is the minimum Guide Pin Housing Bronze required discharge from each of the Guide Pins Stainless Steel total number of"design sprinklers" as or Bronze specified in NFPA 13D or NFPA 13R. Support Cup Steel The number of "design sprinklers" Cover Plate Copper specified in NFPA 13D and 13R for wet . Retainer Brass pipe systems is to be applied when Cover Plate designing dry pipe systems. Ejection Spring Stainless Steel Hydraulic Design Operation (NFPA 13) For systems designed to NFPA 13,the When exposed to heat from a fire,the number of design sprinklers is to be Cover Plate, normally soldered the four which is I r most hydraulically demanding required The minimum rinklersre to the Support Cup at three points,falls sprinklers. q ed dis- away to expose the sprinkler assembly. charge from each of the four sprinklers At this point the Deflector supported by is to be the greater of the following: the Arms drops down to its operated • the flow rates given in Tables A and position. The fusible link of the sprin- B as a function of temperature rat- . kler assembly is comprised of two link ing and the maximum allowable cov- halves that are soldered together with erage area a thin layer of solder. When the rated • a minimum discharge of temperature is reached, the solder 0.1 gpm/ft.2 over the design area melts and the two link halves separate comprised of the four (4) most allowing the sprinkler to activate and hydraulically demanding sprinklers flow water, for actual coverage areas protected by the four(4)sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. 1 TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2'3 Maximum Maximum • Coverage Spacing Ordinary Temp.Rating Minimum Area ac160°F(71°C) Ft.x Ft. FtFlow Pressure Deflector to Installation Spacing (m x m) (m) Ceiling Type Ft. gpm Psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed 16 x 16 16 13 7.0 Ceilings per 8 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2,4) 13R,or 13. Installed in 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2,3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area Ft. 160°F(71°C) Ft,x Ft. (m) Flow Pressure Deflector to Installation Spacing (m x m) Ceiling Type Ft. 9Pm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0.48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed 16 x 16 16 15 9.4 Ceilings per 8 NFPA 13D or Concealed (4,9 x 4,9) (4,9) (56,8) (0,65) 13R,or 13. (2,4) Installed in 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage - area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications.the greater of 0.1 gpm/ft.'over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation Step 6. Screw on the Cover Plate Care must be exercised to avoid Assembly until its flange comes in damage before,during,and after instal- TYCO RAPID RESPONSE Series LFII contact with the ceiling. lation. Sprinklers damaged by drop- Residential Concealed Pendent Sprin- Do not continue to screw on the Cover ping, striking, wrench twist/slippage, klers (TY3596) must be installed in Plate Assembly such that it lifts a or the like, must be replaced. accordance with this section. ceiling panel out of its normal position. The owner is responsible for the General Instructions If the Cover Plate Assembly cannot inspection,testing,and maintenance of Damage to the fusible Link Assembly be engaged with the Mounting Cup their fire protection system and devices during installation can be avoided by or the Cover Plate Assembly cannot in compliance with this document, as handling the sprinkler by the support be engaged sufficiently to contact the well as with the applicable standards cup only(i.e., do not apply pressure to ceiling, the Sprinkler Fitting must be of the National Fire Protection Asso- the fusible Link Assembly). repositioned. ciation (e.g., NFPA 25), in addition to the standards of any other authorities A 1/2 inch NPT sprinkler joint should be Care and having jurisdiction.Contact the install- obtained with a minimum to maximum ing contractor or product manufacturer torque of 7 to 14 lbs.-ft.(9,5 to 19,0 Nm). with any questions. Higher levels of torque may distort the Maintenance The owner must assure that the sprin- sprinkler inlet with consequent leakage TYCO RAPID RESPONSE Series LFII klers are not used for hanging any or impairment of the sprinkler. Residential Concealed Pendent Sprin- objects and that the sprinklers are only Do not attempt to compensate for klers (TY3596) must be maintained cleaned by means of gently dusting insufficient adjustment in the Cover and serviced in accordance with this with a feather duster; otherwise, non- Plate / Retainer Assembly by under- section. operation in the event of a fire or inad- or over-tightening the Sprinkler. Read- vertent operation may result. just the position of the sprinkler fitting Before closing a fire protection system to suit. main control valve for maintenance Automatic sprinkler systems should be work on the fire protection system inspected,tested,and maintained by a Step 1. The sprinkler must only be which it controls, permission to shut qualified Inspection Service in accor- installed in the pendent position and down the affected fire protection dance with local requirements and/or with the centerline of the sprinkler per- system must be obtained from the national codes. pendicular to the mounting surface. proper authorities and all personnel Step 2. Remove the Protective Cap. who may be affected by this action must be notified. Step 3. With pipe thread sealant applied to the pipe threads, and using Absence of a Cover Plate may delay the the W-Type 18 Wrench shown in Figure sprinkler operation in a fire situation. 2, install and tighten the Sprinkler / When properly installed, there is a Support Cup Assembly into the fitting. nominal 1/8 inch (3,2 mm) air gap The W-Type 18 Wrench will accept a between the lip of the Cover Plate and 1/2 inch ratchet drive. the ceiling, as shown in Figure 3.This Step 4.Replace the Protective Cap by air gap is necessary for proper opera- pushing it upwards until it bottoms out tion of the sprinkler by allowing heat against the Support Cup.The Protec- flow from a fire to pass below and tive Cap helps prevent damage to the above the Cover Plate to help assure Deflector and Guide Pins during ceiling appropriate release of the Cover Plate installation and/or during application of in a fire situation. If the ceiling is to be the finish coating of the ceiling. It may repainted after the installation of the also be used to locate the center of the Sprinkler, care must be exercised to clearance hole by gently pushing the ensure that the new paint does not seal ceiling material against the center point off any of the air gap. of the Cap. Factory painted Cover Plates must not Note:As long as the protective Cap be repainted.They should be replaced, remains in place,the system is consid- if necessary, by factory painted ered to be"Out Of Service." units. Non-factory applied paint may adversely delay or prevent sprinkler Step 5. After the ceiling has been operation in the event of a fire. _ completed with the 2-1/2 inch(63 mm) Do not pull the Cover Plate relative to diameter clearance hole and in prep- the Enclosure.Separation may result. aration for installing the Cover Plate Assembly,remove and discard the Pro- Sprinklers which are found to be tective Cap,and verify that the Deflec- leaking or exhibiting visible signs of tor moves up and down freely. corrosion must be replaced. If the sprinkler has been damaged and Automatic sprinklers must never be the Deflector does not move up and painted, plated, coated, or otherwise down freely,replace the entire sprinkler altered after leaving the factory.Modi- assembly. Do not attempt to modify or fied or over heated sprinklers must be repair a damaged sprinkler. replaced. TFP442 Page 6 of 6 Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and part number(P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprinkler, P/N(specify): Ivory(RAL1015) P/N 56-202-0-135 Beige(RAL1001) P/N 56-202-2-135 Pure White*(RAL9010) P/N 56-202-3-135 Signal White**(RAL9003) P/N 56-202-4-135 Grey White(RAL9002) P/N 56-202-5-135 Brown(RAL8028) P/N 56-202-6-135 Black(RAL9005) P/N 56-202-7-135 Brushed Brass P/N 56-202-8-135 Brushed Chrome P/N 56-202-9-135 Custom Paint P/N 56-202-X-135 Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify:W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright®2015 Tyco Fire Products,LP. All rights reserved. t C TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqccs I Fire & Building Products rapid response HOME FIRE SPRINKLER SYSTEM Technical Services:Tel:(800)381-9312/Fax: (800)791-5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Data Description D4 p Tyco Fire & Building Products (TFBP) Sizes '- BlazeMaster CPVC Pipe and Fittings 3/4"to 3" are designed exclusively for use in wet Maximum Working Pressure a pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound corn- Approvals posed of post chlorinated polyvinyl UL, FM, CUL, NSF, Dade County, , chloride(CPVC) resin and state of the LPCB,MEA,and the City of Los Ange . art additives. TFBP BlazeMaster les. (Refer to IH-1900, Rev. 0, Janu- CPVC products are easier to install ary 2005 "Installation Instruction & than traditional steel pipe systems, Technical Handbook" for exact list- and at the same time,provide superior ing/approval information) !41, heat resistance and strength as corn- Manufacture Source pared to traditional CPVC and PVC U.S.A. piping materials used in the plumbing trade. Various adapters are available Material to connect CPVC pipe to metallic pip- • pipe:ASTM F442, SDR 13.5 ing. All female pipe thread adapters have brass inserts for durability. • Fittings: ASTM F438 (Sch. 40) and Grooved adapters connect directly to ASTM F439(Sch.80),ASTM F1970 grooved end valves and metallic pipe, Color with flexible grooved end couplings. Orange WARNING Tyco Fire& Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. BlazeMaster®is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFP1915 Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT.OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. lbs./ft. lbs./ft. PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 FIGURE 1—PIPE DIMENSIONS Installation Care and Tyco Fire and Building Products Maintenance (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- The owner is responsible for the fin- ance with IH-1900, Rev. 0, January spection, testing, and maintenance of 2005"Installation Instruction&Techni- their fire protection system and de- cal Handbook". vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls,permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. 1 TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (TIO) (lb.) ' TEE 80000 3/4" 5/8" 40 0.11 1/0 80001 1" 11/16" 40 0.19 J J- 80002 1-1/4" 7/8" 40 026 -ii. 80003 1-1/2" 1-1/16" 80 0.51 ammo ) 80004 2" 1-3/8" 80 0.90 mwAw80005 2-1/2" 1-9/16" 80 1.59 T/0 111111T/0 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 80132 3/4"x3/4"x 1" 3/4" 3/4" 5/8" 40 0.14 80133 1"x 314"x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1"x 3/4"x 1" 3/4" 11/16" 3/4" 40 0.17 80260 1"x 1"x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4"x 1"x 3/4" 5/8" 5/8" 15/16" 40 021 80136 1-1/4"x 1"x 1" 3/4" 3/4" 15/16" 40 022 80137 1-1/4"x 1"x 1-1/4" 15/16" 15/16" 7/8" 40 026 REDUCING TEE 80261 1-1/4"x 1-1/4"x 3/4" 5/8" 5/8" 7/8" 40 023 80262 1-1/4"x 1-1/4"x 1" 3/4" 314" 7/8" 40 026 Z 80138 1-1/4"x 1-1/4"x 1-1/2" 1" 1" 1" 80 0.43 JITIO 80140 1-1/2"x 1-1/4"x 3/4" 9/16" 9/16" 1" 80 0.36 -- 80141 1-1/2"x1-1/4"x1" 9/16" 9/16" 1-1/16" 80 0.38 m 80263 1-1/2"x 1-1/2"x 3/4" 9/16" 9/16" 1" 80 0.36 X..•-Y I 80264 1-1/2"x 1-112"x 1" 9/16" 9/16" 1-1/16" 80 0.38 T/O •11 80275 1-1/2"x 1-1/2"x 1-1/4" 7/8" 7/8" 1" 80 0.45 T/O 80265 2"x 2"x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2"x 2"x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2"x 2"x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74 80267 2"x 2"x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2"x 2-1/2"x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2"x 2-1/2"x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2"x 2-1/2"x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-1/2"x 2-1/2"x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3"x 3"x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 228 80268 3"x 3"x 2" 1-13/16" 1-13/16" 1-3/4" 80 225 80269 3"x 3"x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44 CROSS&REDUCING CROSS 80009 3/4" 9/16" 40 0.13 80010 1" 11/16" 40 023 JL. T/O 80011 1-1/4" 15/16" 40 0.34 80012 1-1/2" 1-1/16" 80 0.67 .11111-■ 80013 2" 1-5/16" 80 1.00 X11 1. 80014 2-1/2" 1-9/16" 80 1.91 i..il TIO 80008 3" 1-13/16" 80 2.89 T/0 ■■ T/0 80015 1"x 1"x 3/4"x 3/4" 7/8" 40 028 90°ELBOW& 80025 3/4" 5/8" 40 0.09 REDUCING ELBOW 80026 1" 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 - X 80028 1-1/2" 1-1/16" 80 0.40 It T/0 80029 2" 1-5/16" 80 0.79 " ..� ) 80030 2-1/2" 1-9/16" 80 1.14 MIMI80031 3" 1-13/16" 80 1.82 •in im� Y XzY X Y - -T/0 80032 1"x 3/4" 11/16" 13/16" 40 0.16 FIGURE 2-FITTING DIMENSIONS(Part 1 of 4) Page Pay4of6 TFP1915 I FITTING PART NOMINAL TAKE-OUT WEIGHT NOMINAL SIZE SCHD. TYPE NUMBER (TIO) (Ib.) 45°ELBOW 80050 3/4" 3/8" 40 0.08 T/080051 1" 3/8" 40 0.11 480052 1-1/4" 3/4" 40 020 T/O* h• 80053 1-1/2" 1/2" 80 0.31 All. 80054 80055 2" 2112" 3/4" 13/1 " 80 0.56 . p� 6 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING& 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 C ' ' 80078 1-1/2" 3/16" 80 0.25 80079 2" 3/16" 80 0.38 80080 2-1/2" 1/4" 80 0.67 -� T/0 80081 3" 3/16" 80 0.91 80220 1"x 3/4" 1/8" 40 0.08 80200 1"x 3/4" 7/16" 40 0.04 80201 1-1/4"x 3/4" 1/2" 40 0.11 80202 1-1/4"x 1" 5/16" 40 0.12 80203 1-1/2"x 3/4" 5/8" 80 0.16 80204 1-1/2"x1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2"x 1-1/4" 3/8" 80 0.17 80206 2"x 3/4" 13/16" 80 0.27 ', 80207 2"x 1" 11/16" 80 026 80208 2"x 1-1/4" 9/16" 80 024 �(',L 80209 2"x 1-1/2" 7/16" 80 0.19 -I f-T/O 80215 2-1/2"x 1" 15/16" 80 0.42 80214 2-1/2"x1-1/4" 13/16" 80 0.45 80213 2-1/2"x 1-1/2" 11/16" 80 0.46 80211 2-1/2"x 2" 5/8" 80 029 80210 3"x 2" 3/4" 80 0.72 80212 3"x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 �``� 80102 1-1/4" 7/16" 40 0.10 s, /fin/ 80103 1-1/2" 11/11/16" 80 0.20 80104 2" 5/8" 80 0.31 T/0-1 L 80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER rt..........�� 80160 1-1/4"x 1-1/4"Groove 2-5/16" 1-1/4"(1.660") 40 0.78 80161 1-1/2"x 1-1/2"Groove 1-1/2"(1.900") 80 0.95 1%.-7,-.... ` PIPE 80162 2"x 2"Groove 2 5/16" 2-5/16" 2"(2.375") 80 '1.42 O.D. 80163 2-1/2"x 2-1/2"Groove 2-5/16" 2-1/2"(2.875") 80 2.28 80164 3"x 3"Groove 2-1/4" 3"(3.500") 80 3.00 -T/0-I 80169 2-1/2"x 76,1 mm Groove 2-5/16" 76,1 mm(3.000") 80 2.28 FIGURE 2-FITTING DIMENSIONS(Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (TIO) (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4"x 1/2"NPT 7/16" 80 0.20 80176E 1"x 1/2"NPT 7/16" 80 022 p......., 80175WL 3/4"x 1/2"NPT 7/16" 40 0.16 80179 1"x 3/4"NPT 13/16" 40 0.43 - T/o SPRINKLER HEAD ADAPTER 80175W 3/4"x 1/2"NPT 1/2" 40 0.19 80176W 1"x 1/2"NPT 1/2" 40 0.18 T/O SPRINKLER HEAD ADAPTER(SPIGOT) ..re,„l 80177L 3/4"x 1/2"NPT 1/2" 40 0.16 -��g80178 1"x 1/2"NPT 9/16" 40 020 r 80180 1"x 3/4"NPT 7/8" 40 0.40 -I T/O FEMALE ADAPTER ,,q77 80142 3/4"x 3/4"NPT 13/16" 40 0.41 180145 1'x 1"NPT 7/8" 40 0.63 80146 1-1/4"x 1-1/4"NPT 1-1/8" 40 1.03 ��`�����` 80147 1-1/2"x 1-1/2"NPT 1-3/8" 80 1,42 80148 2"x 2"NPT 1-11/16" 80 2.66 - -T/O MALE ADAPTER IIiug 80157 3/4"x 3/4"NPT 1-5/16" 40 0.33 wwwwwal 80158 1'x 1"NPT 1-3/8" 40 0.56 T/O XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4"x 3/4"x 1/2"NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1"x 1"x 1/2"NPT 11/16" 11/16" 1-3/16" 40 029 ;_=`� T/0 80249 1"x 1"x 1"NPT 15/16" 15/16" 1-9/16" 40 0.73 Ikl) 80256 1-1/4"x 1"x 1/2"NPT 7/16" 9/16" 1-5/16" 40 0.30 -`.- 80252 1-1/4"x 1-114"x 1/2"NPT 7/16" 7/16" 1-5/16" 40 0.31 X -..-Y80257 1-1/2"x 1-114"x 1/2"NPT 1/2" 11/16" 1-7/16" 80 0.43 NIIIIIIIIIIIIMMI M, .4 80254 1-1/2"x 1-1/2"x 1/2"NPT 1/2" 1/2" 1-7/16" 80 0.46 T/O •• T/O 80258 2"x 1-1/2"x 1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2"x 2"x 1/2"NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2—FITTING DIMENSIONS(Part 3 of 4) Page 9 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) BACK-TO-BACK TEE X x Y x Z X y Z X , T/0 I Y` 07:=-Zx"•A � - 80459 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.48 \��� Z I 80460 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 ....ter' T/0 T/O BACK-TO-BACK CROSS X x Y x Z x W X,Y Z,W X � t T/O z.:...i ; .. IIIII 'Wi111111 80462 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 1• I 7 ♦'"— 80463 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.47 T/0 1 T/O TIO SPRINKLER HEAD X x Y X Y ADAPTER 90°ELBOW Y ,"qI T/0 Itw, 80199 3/4"x 1/2"NPT 9/16" 1" 40 0.20 TIMM ` 80198 1"x 1/2"NPT 3/4" 1-1/4" 40 0.26 .'-X 80196 1"x3/4"NPT 1-1/16" 1-7/16" 40 0.26 oma` T/0 FIGURE 2—FITTING DIMENSIONS(Part 4 of 4) Limited by TFBP to be defective shall be either of merchantability and fitness for a par- repaired or replaced, at TFBP's sole ticular purpose. option. TFBP neither assumes, nor Warrant This limited warranty sets forth the ex- clusive remedy for claims based on Products manufactured b T Fire& any other obligation in connection with failure of or defect in products, materi- Y Y co the sale of products or parts of prod- als or components, Building Products (TFBP) are war- ucts.TFBP shall not be responsible for whether the claim is made in contract, tort, strict liability ranted solely to the original Buyer for sprinkler system design errors or inac- • ten(10)years against defects in mate- curate or incomplete information sup or any other legal theory. rial and workmanship when paid for plied by Buyer or Buyer's repre- This warranty will apply to the full ex- and properly installed and maintained sentatives. tent permitted by law.The invalidity, in under normal use and service. This In no event shall TFBP be liable, in whole or part, of any portion of this warranty will expire ten (10) years warranty will not affect the remainder. , from date of shipment by TFBP. No contract, tort, strict liability or under warranty is given for products or corn- any other legal theory, for incidental, ponents manufactured by companies indirect,special or consequential dam- not affiliated by ownership with TFBP ages, including but not limited to labor - or for products and components which charges, regardless of whether TFBP have been subject to misuse,improper was informed about the possibility of installation, corrosion, or which have such damages, and in no event shall not been installed, maintained, modi- TFBP's liability exceed an amount fled or repaired in accordance with ap- equal to the sales price. plicable Standards of the National Fire The foregoing warranty is made in lieu Protection Association, and/or the of any and all other warranties. ex- standards of any other Authorities press or implied. including warranties Having Jurisdiction. Materials found TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Dyna-Thread® - M-COAT® Submittal Data Sheet ® Full Line Sch-40 Replacement Dyna-Thread—Ni-COAT Specifications Dyna-Thread®—M-Coat sprinkler pipe represents an engineering NPs Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded Threaded, and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — — 11/4" 1.408 1.870 2.54 9.50 1.00 O Comparison to Schedule 40 32 35.8 2.8 3.78 - 11/2" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread°—M-Coat"inside diameter is up to 3.6% larger than Sch-40 40 41.6 3.4 4.79 giving it superior hydraulics.Also,when used in combination with Dyne- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe, down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall UL c(2) 40/ thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— APPR,YE, M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for O American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S. Facilities and is available and lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada, Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR) is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed ®Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints. Dyna-Thread— use in wet systems. Dyna Thread—M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.O.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. .Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com 9- allied • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE &CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix,AZ 85009 gPART Or L,atkore rc»nn &tknra Intarnatinnal In,- ill Rinhtc Racan,arl CTP-c A-12n1 ES-A-2000B A. Series 2000B AMES Double Check Valve Assemblies FIRE&WATERWORKS Sizes: 121" —2" (15—50mm) Features f - • Ease of maintenance with only one cover 2"2000B HC • Top entry (50mm) • Replaceable seats and seat discs - • Modular construction • Compact design • 12"-2" (15-50mm)Cast bronze body construction a/e"2000B • Top mounted ball valve test cocks (20mm) • Low pressure drop • No special tools required Series 2000B Double Check Valve Assemblies are designed to protect drinkingwater sup • /2"-1" (15-25 mm)have plies for dangerous cross-connections in accordance with natioal plumbing cdes and tee handles water authority requirements for non-health-hazard non-potable service applications such as irrigation,fire line,or industrial processing. Available Models These valves meet the requirements of ASSE Std. 1015 and AWWA Std.C510 and are Suffix: approved by the Foundation for Cross-Connection Control and Hydraulic Research at the B- Quarter turn ball valves University of Southern California. LBV- less ball valves Specifications SH- stainless steel ball valve handles A Double Check Valve Assembly shall be installed at each noted location.The assembly HC- 21/2" inlet/outlet fire hydrant fitting shall consist of two positive seating check modules with captured springs and rubber seat (2"valve) discs.The check module seats and seat discs shall be replaceable.Service of all internal components shall be through a single access cover secured with stainless steel bolts. Pressure —Temperature The assembly shall also include two resilient seated isolation valves and four top mounted, Temperature Range:33°F-140°F resilient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 (0.5°C-60°C) and AWWA Std.C510.Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California.Assembly shall be an Ames Maximum Working Pressure: 175psi Company Series 2000B. (12.1 bar) Approvals Standards AWWA Std.C510, IAPMO PS31 0 c011/ O C ® US us 1015 B64.5 W-2" A WARNING (LBV Models Only) It is illegal to use this product in any plumbing Approved by the Foundation for Cross-Connection Control and Hydraulic Research at system providing water for human consumption, the University of Southern California. such as drinking or dishwashing,in the United LBV models not listed. States.Before installing standard material prod- ' Horizontal and vertical"flow up"approval on all sizes. uct,consult your local water authority,building and plumbing codes. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com I Dimensions -Weights )' �� in is • T 1 �_ aMM�MM�� B ®.l.- • 1 ■�.iiiimi ®a. )110"M���I�' N '---•i■ iliaF Suffix HC - Fire Hydrant Fittings dimension"A" =23' "(594mm) 4 H -i -► g G- SIZE(DN) DIMENSIONS WEIGHT A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 1/2 15 10 254 4% 117 2%6 62 5 127 3% 85 25/6 59 2'/e 52 4.5 2 3/4 20 111/8 282 4 102 31/6 79 63/6 157 3'/%6 87 2'/6 54 1566 33 5 2.3 1 25 1314 337 51/8 130 4 102 71/2 191 3% 85 11'/s 43 11/6 43 12 5.4 11/4 32 16% 416 5 127 35/6 84 91/2 241 5 127 3 76 2 50 15 6.8 112 40 16% 425 4'/6 124 312 89 9% 248 513/6 148 3% 79 2'1A6 68 15.86 72 2 50 1912 495 61/4 159 4 102 13% 340 61/e 156 3'/6 87 21/6 68 25.75 11.7 Strainer sold separately Capacities kPa psi n 11/4" (32mm) As compiled from documented Foundation for Cross-Connection Control 96 14 and Hydraulic Research at the University of Southern California lab tests. " 83 12 aTypical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) vi 69 10 55 8 kPa psi 1/2° (15mm) 3 41 6 n 83 12 �� 0 69 10 2 24 2 J 55 8 B. i- 41 6 r~� 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 7 r^ d 2 AP 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm L. 0 5 7.5 10 15 fps 3. 0 2 4 6 8 10 12 gpm 1.5 2.3 3.0 4.6 mps AP 0 7.6 152 22.8 30.4 38 45.6 pm Flow Rate 5 7.5 10 fps 1.5 2.3 3.0 mps kPa psi 11/2"(40mm) Flow Rate 83 12 a kPa psi 3/4"(20mm) y 69 10 H 152 22 055 8 J 124 18 ` 41 6 96 14 H 14 2 o 0 69 10 i 0 0 d a pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0. 41 6 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 14 2 �~� 5 7.5 10 15 fps 0 5 10 15 26 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps AP 0 19 38 57 76 95 114 133 152 171 190 1pm Flow Rate 7.5 15 fps 2.3 4.6 mps kPa psi e 2" (50mm) Flow Rate 0 83 12 kPa psi a 1"(25mm) 0 69 10 "i 55 8 J 69 10 41 6 . _��• 0 55 8 H 28 4 1,+� •� to 41 6 14 2 rr L 28 4 0 0 0. 14 2 ' 0 25 50 75 100 125 150 175 200 gpm • AP 0 95 190 285 380 475 570 665 760 Ipm 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 5 7.5 10 15 fps nP 0 19 38 57 76 95 114 133 152 171 190 209 228 pm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps Flow Rate . 1.5 2.3 3.0 4.6 mps AFlow Rate AMES FIRE&WATERWORKS A Watts Water Technologies Company USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•Fax:(52)81-8000-7091 •AmesFireWater.com ES-A-2000B 1410 ©2014 Ames Fire&Waterworks Sprinkler Gauge F P P I� Description loo FPPI pressure gauges feature an impact and corrosion resistant case made from ABS(plastic). Features phosphor bronze bourdon tube movement with white °° enameled brass dial face with large numbers for easy reading. Dual scale to 300 ' o0 PSI/2000Kpa. UL/ULc Listed (Sprinkler Gauge Model 111.10SP, UL Listed file °° 4, • EX5232) and FM Approved. u°° e o'"a4'•� Jui G% ' Applications Standard Features Specifications • Fire sprinkler systems Design • Suitable for all media that will not EN 837-1 &ASME B40.100 Bourdon Tube obstruct the pressure system or Sizes Material:copper alloy C-type attack copper alloy parts 4" (100 mm) Pressure Connection Accuracy class Material:copper alloy Special Features 1/4 NPT lower mount(LM) p ±32/3% of span • UL-listed (UL-393), United States (ASME B40.100 Grade B) Movement and Canada(Sprinkler Gauge Ranges Copper alloy Model 111.10SP, UL Listed file 0/80 psi, retard to 250 psi (air) Dial EX5232) 0/300 psi (air, water, air/water) White aluminum with stop pin; • Factory Mutual (FM)approved Working Pressure black and red lettering • Reliable and economical Steady: 3/4 of full scale value Pointer Fluctuating: 2/3 of full scale value Black aluminum Short time: full scale value Operating Temperature Case Black polycarbonate Ambient: -40°F to 140°F (-40°C to 60°C) Window, Media: 140°F (+60°C) maximum Snap-in clear polycarbonate Temperature Error • Additional error when temperature changes from reference temperature of 68°F(20°C) +0.4% for every 18°F • (10°C) rising or falling. Percentage of span. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 ©2012 Fire Protection Products.Inc. 111111. . . • l Model 1000 .. A la TESTAN D RAI N Sectional Floor Control Test and Drain Valve® c (1) us 11> APPROVED 3/4" 1" 114" 1� " 2" ,:�s: � tF yds; TEST ' v2°a o . . ICE, PUSH 4, r-,-,TTESTANDRAiN MOREL MO .". DRAIN FITTING SPECIAL TYPE <> p AGF 411"'""'". fg.Ipc..Malrarn.PA. a t } }vvco).,„4 b ,xC f y, ,,, 6 .` .py §i'TxR4 f t ::,:,,,,,f,-,,,,,,,- 13 Sr - I V T ., C. -L;,-,i "f fit, r ' ,,2 t •The AGF Manufacturing Inc. Model 1000 TESTANDRAIN MODEL 1000- FRONT VIEW,VERTICAL INSTALLATION provides both the test function and the express drain function for a wet fire sprinkler system. • The Model 1000 complies with the requirements of FROM BRANCH NFPA-13, NFPA-13R, and NFPA-13D. 111•The Model 1000 TESTANDRAIN®is a compact single SYSTEAIM ACCESS PORT handle ball valve which includes a tamper resistant test ��� orifice and integral tamper resistant sight glasses, and is . 1 300 PSI rated. �� •Available in a full range of sizes from 3/a" to 2" NPT and �' IlEcium �I BSPT,with all specifiable orifice sizes 3/a" (2.8K), 7/16" (4.2K), STREET EL I . '/2" (5.6K), 17/32" (8.0K), MI" (11.2K, ELO), 34" (14.0K, ESFR), O, and K25 as required by NFPA 13, 2007 Edition (see reverse). i11111.1 •The orifice size is noted on the indicator plate and the valve � features a tapped and plugged port for system access. STREET EL liiimp„� TO DRAIN •A locking kit is available and can be ordered with the valve OR PIPE I • t I toprovide vandal resistance or prevent unintentional alarm TO DRAIN li activation. • • Repair kits including (1)adaptergasket, (1) ball, (2)valve seats, (1) stem packing, and (1) stem washer are available for all TESTANDRAINe.valves.Valve and orifice size must RIGHT HAND/STRAIGHT INSTALLATION be specified when ordering. Reliability, VersatilitY� Code Compatibility Y TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS7 000 10/09 Model 1000 i Ala c CI) us mTESTAN DRAIN® APPROVED 300 PSI Bronze Ball Valve MODEL 1000 - PLAN VIEW FRONT VIEW - HORIZONTAL INSTALL I A - E---b-I • 1/2"NPT SYSTEM F ej 1.., , ACCESS PORT B $1104 it • TO RAIN 1 PEI r�� : TO DRAIN .%1111°--- F" ' l J 1 J . i • ,. _ _ 1 0 - 1 ,MINI El DIMENSIONS MATERIALS Orifice Size Available:3/s",7/16",1/2", 17/32", ELO(5/8")*, ESFR(3/4")*, &K25** Handle: Steel Stem: Rod Brass SIZE A B C D E F G H Ball:C.P. Brass 3/4,, 51/16" 11/2" 23/16" 35/8" 33/8" 11346" 49/16" 63/8" Body: Bronze (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) Valve Seat: Impregnated Teflon`" 51/16" 11/2" 23/16" 3W' 33/8" 11346" 49/16" 63/8" Indicator Plate:Steel 1 (128 mm Handle Stop:Steel (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) p' 11/4" 57A6" 111/16" 29/16" 41/4" 3546" 115/16" 59/16" 51/2" APPROVALS (163 mm) (43 mm) (65 mm) (108 mm) (83 mm) (51 mm) (141 mm) (192 mm) UL and ULC Listed (EX4019) 11/2" 67/1x" 113/16" 31/4" 5146" 37/s" 25/8" 81/4" 107/8" FM Approved (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) NYC-BSA No.720-87-SM 2" 6746" 113/6" 31/4" 51A6" 37/8" 25/8" 81/4" 107/8" (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) x,* rrr*i *Available on 11/4" to 2" size units only «7;;*; 00.1.111 **Available on 11/2" and 2" size units only r«'`** THE MODEL 1000 PROVIDES ALL OF THE FOLLOWING... ^�� MADE IN U.S.A. From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)-shall be provided with a drain &8.16.2.4.3 connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore 1 corrosion-resistant orifice,to provide a flow equivalent to one sprinkler... .Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1", at least one of which shall be brass. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: Ala100 Quaker Lane,Malvern, PA 19355 Phone:610-240-4900 Architect: Fax:610-240-4906 Engineer: www.testandrain.com Contractor: P PYrrEJ FOR SMALL PIPE 1TSR-S • VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC,CSFM Listed and NYMEA Accepted Service Pressure: Up to 300 PSI(20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)UL Maximum Surge: 18 FPS(5,5 m/s) Enclosure: Die-cast,red enamel finish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Resistive l OmAmps min.at 24 VDC Conduit Entrances:Two openings provided for 1/2"conduit. individual switch compartments suitable for I dissimilar voltages. Usage: Listed plastic,copper and schedule 40 iron pipe. Fits pipe sizes- 1"(25mm), 1 1/4"(32mm), 1 1/2"(38mm) and 2"(50mm) Stock No. 1144440 Note: 12 paddles are furnished with each unit,one for each pipe size of threaded and sweat TEE,one for 1"(25mm)CPVC, one for 1"(25mm)CPVC(Central),one for 1"threaded Nibco } u CPVC,and one for 1 1/2"(38mm)threaded(Japan). Environmental Specifications: •""" �' "°"" �_ • NEMA-4/IP54 Rated enclosure suitable for indoor or outdoor Installation must be perfomed by qualified personnel and in use with factory installed gasket and die-cast housing when used accordance with all national and local codes and ordinances. with appropriate conduit fitting. Shock hazard. Disconnect ower source before servicing. • Temperature range:40°F to 120°F,(4,5°C to 49°C)UL Serious injury or death could result. Service Use: Risk of explosion. Not for use in hazardous locations. Serious Automatic Sprinkler NFPA-13 injury or death could result. One or two family dwelling NEPA-13D Residential occupancy up to four stories NEPA-13R National Fire Alarm Code NFPA-72 Optional:Cover Tamper Switch Kit,Stock No.0090148 (See Fig.7 for terminations) Replaceable Components:Retard/Switch Assembly,stock no. 1029030 The Model VSR-S is a vane type waterflow switch for use on wet Installation sprinkler systems that use 1"(25mm),11/4"(32mm),11/4"(38mm)or 2" These devices may be mounted in horizontal or vertical pipe. On (50mm)pipe size.The unit may also be used as a sectional waterflow horizontal pipe they should be installed on the top side of the pipe where detector on large systems. they will be accessible.The units should not be installed within 6"(15cm) of a valve,drain or fitting which changes the direction of the waterflow. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are Select the proper paddle for the pipe size and type of TEE used see Fig. actuated when a flow of 10 gallons per minute(38 LPM)or more occurs 1 for instructions on changing paddle. The unit has a 1"NPT bushing downstream of the device.The flow condition must exist for a period of for threading into a non-corrosive TEE.See Fig.2 for proper TEE size, time necessary to overcome the selected retard period. type and installation. Use no more than three wraps of teflon tape. Enclosure Screw the device into the TEE fitting as shown in Fig.2.Care must be The VSR-S sw itches and retard device are enclosed in a general purpose, taken to properly orient the device for the direction of waterflow. die-cast housing.The cover is held in place with two tamper resistant The vane must not rub the inside of the TEE or bind in any way. The screws which require a special key for removal.Afield installable cover stein should move freely when operated by hand. • tamper switch is available as an option which may be used to indicate The device can also be used in copper or plastic pipe installations with unauthorized removal of the cover. See bulletin number 5401103 for the proper adapters so that the specified TEE fitting may be installed installation instructions of this switch. on the pipe run. Note:Do not leave cover off for an extended period of time. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG 454012206-REV G PAGE t OF 3 12/08 FOR SMALL PIPE VSR—S • P POTTER VANE TYPE WATERFLOW e The Symbol of Protection ALARM SWITCH WITH RETARD • Fig. 1 Fig.2 I Retard Adjustment 170 Nt/11 EAVE COvER of FFLRE'X1ENDE.PE1.40005FlOE FL/3w e.37.iN ,,,,,,,_„t—.... 1 11/1 K'/ The t ime delay is factory set at 30±10 seconds. co\ERTSDiPERS\\ITCH t The delay can be adjusted by rotating the retard �t adjustment knob from 0 to the max setting(60- �' .�}ui I ` DEPre ) 90 seconds).The time delay should be set at the �,�I.j4 minimum required to prevent false alarms. �� �'IS♦'j J + fr. „r i!•\�`;-,I ado" Screw the device into the tee fitting as shown. a:d` �/ Care must be taken to properly orient the DIRECTION OF / MOUNT 50 ��^'�jy^ . • w_„ERF Ow \_Apo. device for the direction of waterflow.On sweat ARROW ON IN DIRECTION OF � tees,no threaded bushings,inserts,or adapters / IN DIRECTION UE Ng J� WATERFLOW are permitted,unless they comply with the ,`_ dimensions listed in the chart below. DW6THR A oN Important-The depth to the inside bottom of ATING OS the tee should have the following dimensions: '•��` •”' Rl7N OF Tt '1'EE /--,,„„.-:----,t,, � Approximate Depth Regt�iremem MAY BE ^Q There are 12 paddles furnished with each unit 1!TREADED OR �) Tee Size Threaded Sweat CPVC SRE4T PIPE One for each size of threaded,sweat or plastic 1"x r'x 1" 2 1,16" 1 3/4" 2 7/16 utR-='1',oF (`(-�I,,, TEE as described in Fig.2.These paddles have ,x:ATEttrl,)ty 1\� 11,x^x 1 lra^x 1^ 2 7n6^ 2-/16° NrA raised lettering that shows the pipe size and type �\ GW,au,m,. 1 1 2"x 1 1/2"x 1" 2 11/16" 2 1/4" Ni A of 1 EE that they are to be used with.The proper 2"x 2"x 1" 3 3/16" 2 3u" N/A pddlemustbeused.Thepracldlemustbeproperly Shown with optional Cover Tamper Switch Kit. attached(see drawing)and the screw that ::',10AriNti6'.177 Nlt6' the paddle must be securely tightened. Do not use more than three wraps of teflon tape. Fig.3 Switch Terminal Connections Clamping Plate Terminal Fig.7 Cover Tamper Switch Wiring (Shown with cover in place) .�.. ,,;L3:�1 a.....,,.A. 2°.�x.., ��-LI.,u smu6.Ls-.'iicb,. _,.. , i'' An uninsulated section of a single conductor should not be looped s around the terminal and serve as two separate connections.The wire .,'� DW„ o2/0 must be severed,thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. C N.O. N.C. Failure to sever the wire may render the device inoperable risking (WHT) (RED) (BLK) severe property damage and loss of life. DWG=wows, Fig.4 Typical Electrical Connections Fig.5 Fig.6 To remove knockouts: Breakout thin sectionofcoverwhenwiring t NEh.ATIAE Di:OR +; .� NEu1xal.Ac Place screwdriver at edge of both switches from one conduit enri�unce. t 3 knockouts,not in the center. +' POSITIVE DO OR •— 0 0 0 HOT AC I Ill_ �I .-- i •—• -11 /- 1_ - —i-� 000, ` jr �"�� �'\\ �10 �� , . 1 nrft: ft ZONE ON • ® ® FIRE P/NFL 1/1 �-.7.:- \^... ♦ ,Fates: /1 •1. The Model VSR-S has two switches,one can he used to operate a w—' central station,proprietary or remote signaling unit,while the other '� is used to operate a local audible or visual annunciator. u 2. For supervised circuits see"Switch Terminal Connections"drawing v n" and caution note(Fig. 3). PRINTED IN USA MFG#5101206-REV(3 PAGE 2 OF 3 12,08 P PYFFFR FOR SMALL PIPE vJSR_S • VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD • Testing Removal The frequency of inspection and testing for the Model VSR-S and its • To prevent accidental water damage,all control valves should associated protective monitoring system should be in accordance with be shut tight and the system completely drained before waterflow applicable NFPA Codes and Standards and/or the authority having detectors are removed or replaced. jurisdiction(manufacturer recommends quarterly or more frequently.) • Turn off electrical power to the detector,then disconnect wiring. An inspectol'stestvalve(usually located at the end ofthemost remote branch • Use a wench on the flats of the bushing.Turn the switch line)should always be used for test purposes.If there are no provisions for counterclockwise to disengage the pipe threads. testing the operation of the flow detection device on the system,application • Gently lift w ith your fingers,roll the vane so it will fit through the of the VSR-S is not recommended or advisable. hole while continuing to lift the waterflow detector. A minimum flow of 10 gpm(38 Lpm)is required to activate this device. • Lift detector clear of pipe. NOTICE Please advise the person responsible for testing of the a CAUTION CAI fire protection system that this system must be tested in accordance with V lJ X11 the testing instructions. Waterflow switches that are monitoring wet pipe sprinkler systems Maintenance shall not he used as the sole initiating device to discharge AFFF, Inspect detectors monthly for leaks. If leaks are found, replace the deluge,orchemical suppression systems.Waterflowswitches used detector.The VSR-S waterflow switch should provide years of trouble- for this application may result in unintended discharges caused free service.The retard and switch assembly are easily field replaceable. by surges,trapped air,or short retard times. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock 41029030.There is no maintenance required,only periodic testing and inspection. Mounting Dimensions 3.50" ► 5.56" GROUND SCREWS (89.0 mm) (141,2 mm) A I43 �i�,l�� (502. 0" ILI_I_.:I_I 1 JH) 2.34., Ii. (59.4mm)- 1 f--ii 4.89" ■ ��(il1ttiI� TC� _- l._il �VI ''' ., (52.3 mm) iEI = w� III �ro 1"-11 1/2 NPT DWG#1206-5 • • • PRINTED IN USA MFG 45.101206-REV G PAGE 3 OF 3 12/08 .47./ Ig • P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER t7 50 Fastener SIZE Dim. Q-rt 3/4 2.125 0 1 2.312 1 1/4 3.170 1 1/2 3.400 B 2 4.010 2 1/2 4.320 3 5.320 SIZE-SYSTEM PIPE: 3/4" thru 3" MATERIAL-Carbon Steel. FINISH-Mil. Galvanized. LISTING/APPROVAL- `, E,'"203-EX 4231,EX 2551 FUNCTION-Support horizontal piping: CPVC,Copper or Steel. Size 3/4" -2"Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION- Per these instructions ' including NFPA 13, 13R. 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS- UL Listed per NFPA 13 in WOOD: 3'4"-3"CPVC pipe-#905 screw -no pre-drill. 3/4"-3"Steel and Copper pipe-#14 x 1 1/2" SMS or Restraint 1/4"x11/2"lag bolt-no pre-drill. in STEEL-min. 18 GA. 3/4"-3"CPVC,Copper and Steel pipe- 1/4" or#14 Tek Screw. f I• FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. 1� * Required AFCON#905 screw included-5'16"hex head. Hanger - Stabilize ORDERING-Part#and pipe size. \ • • f• CAN ALSO BE USED TO REPLACE-#500 Pipe Strap #520 Tin Strap Specific AFCO,\products are exclusively designed to be compatible ONLY with other.iFCOY'products including pacts and fasteners.resulting in a listed sway brace.restrainer or hanger assembly. Be advised the fallowing warrano restriction will apply. DISCLAISEER-AFCO''will NOT wan-ant against the tailure of its products when used in combination with other products,pans or systems not manufactured or sold by AFCO,Y.AFCO.\'shall NOT he liable under any circmnstances whatsoever for an direct or indirect.incidental or consequential damages of any kind.including but not limited to loss of business of profit.when non-.4FCON products have been.or are used.