Loading...
Report (31) kSozo1S----- Uv 1II (2o s sw ii-ki k itZ, • INDEX 111 PROJECT: TIGARD DISTRIBUTION CENTER Number Description Manufacturer Model No. 1 Sprinkler Head, TY7126 Tyco ESFR-17 2 Pipe Nap Steel Sch. 10/40 3 Couplings Victaulic Style 009 4 Fittings Victaulic Firelock 5 Butterfly Valve Tyco BFV-N 6 Alarm Switch Potter VSR 7 Beam Clamp Afcon 100 8 Restraining Strap Afcon 162 9 Hanger Ring Afcon 300 10 Sway Brace Fitting Afcon 001/020 11 Attachment Fitting Afcon Locking 077 12 Sway Brace Adapter Afcon Style 086 13 Sway Brace Fitting Afcon Style 410 • S 1 is ! - coWorldwide Fire Protection Contacts www.tyco-fire.com • Products Model ESFR-17 16.8 K-factor Upright Sprinkler Early Suppression, Fast Response General when sizing system piping and posi- tioning the system piping with respect 0-.,'.'' ,''. Description to the ceiling. Applications for the TYCO ESFR Sprin- ., TYCO Model ESFR-17 Upright Sprin- klers are expanding beyond currently ` t klers are Early Suppression, Fast recognized installation standards. For Response (ESFR) sprinklers having a information on research fire tests that nominal K-factor of 16.8(Ref. Figure 1). may be acceptable to an authority They are suppression mode sprinklers having jurisdiction, contact Tyco Fire that are especially advantageous as a Protection Products (TFPP) Technical means of eliminating in-rack sprinklers Services. when protecting high-piled storage. ( �� NOTICE ,� Model ESFR-17 Sprinklers are primarily used for ceiling-only sprinkler protec- The Model ESFR-17 Upright Sprinklers tion of(but not limited to)the following described herein must be installed and storage applications: maintained in compliance with this doc- • most encapsulated or non-encapument, as well as with the applicable sulated common materials including standards of the National Fire Protec- cartoned, unexpanded plastics tion Association (NFPA), in addition to the standards of any authorities having • • cartoned, expanded plastics jurisdiction(e.g., FM Global). Failure to Technical • some storage arrangements of do so may impair the performance of rubber tires and roll paper these devices. Data For more specific criteria,refer to Table The owner is responsible for main- is royals A in this technical data sheet as well as taming their fire protection system PP the applicable design standard. and devices in proper operating con- FM Approved dition. Contact the installing contrac- CE Certified(Certificate of Conformity The Model ESFR-17 Upright Sprin- tor or product manufacturer with any 1725-CPD-H0012) klers provide the system designer with questions. Maximum Working Pressure an upright option to the traditional In all cases, the appropriate NFPA or 175 psi (12,1 bar) pendent ESFR Sprinklers.With a K FM Global installation standard must Pipe Thread Connections tor of 16.8, Model ESFR 17 Sprinklers be referenced to ensure applicabil- 3/ Inch NPT or ISO 7-R 3/4 provide system designers with hydrau ity and to obtain complete installs lic and sprinkler placement options not tion guidelines. The generalguidelines Discharge Coefficient presently available to traditional ESFR in thisdata sheet arnot intended to K=16.8 gpm/psi1/2(241,9 Ipm/bar1/2) Sprinklers having a K-factor of 14.0. In provide complete installation criteria. Temperature Ratings particular, the Model ESFR-17 Upright 165°F(74°C)and 212°F(100°C) Sprinklers are designed to operate at t+sprinkler er substantially lower-end head pressures S Finish compared to ESFR Sprinklers with 14.0 Natural Brass K-factors. This feature offers flexibility Identification Physical Characteristics Number (SIN) Frame Brass Deflector Copper Compression Screw Stainless Steel IMPORTANT TY7126 Hook MONEL Always refer to Technical Data Strut MONEL y Link Assembly Solder,Nickel Sheet TFP700 for the "INSTALLER Button Brass WARNING" that provides cautions Sealing Assembly..Beryllium Nickel w/TEFLON with respect to handling and instal- Ejection Spring INCONEL lation of sprinkler systems and com- Nut Brass ponents. Improper handling and • installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to cpo,lite prematurely. Page 1 of 4 APRIL 2015 TFP316 TFP316 Page 2 of 4 2-9/16"DIA. (65,0 • i (65,0 mm) 10m TEMPERATURE �� ���� RATING cnIm Components: 2 ../"''''#'"--00103111111"--,(( 1 - Frame (�� 1 ••••1 „��. ii I x, 2 - Deflector 3 d=� 3 - Compression WRENCH iiiii Screw FLATS i' 4 - Hook 4 THERMAL 5 - Strut 3-5/8" SENSING 6 - Link Assembly 5 (92,1 mm) ELEMENT 7 - Button 8 - Sealin Assembly 6 �• III 1 9 (1217 mm)ilt /2" ���� 9 - Ejection Spring . 1 NOMINAL Ili10 Deflector Nut8yiMAKE IN �� (411-5/8 ) 41,3 mm i niii.main7 3/4" NPT S 1 f FIGURE 1 MODEL ESFR-17 UPRIGHT SPRINKLER, 16.8K EARLY SUPPRESSION, FAST RESPONSE Desin System Type FM Global g Wet Pipe Centerline of Thermal Sensing Element-to-Ceiling Distance Criteria Roof Construction Refer to FM Global 2-0 for Storage • Unobstructed or obstructed construc- Sprinklers. The following general guidelines pro- tion (e.g., smooth ceiling, bar joists, Obstructions below Upright ESFR vided for the TYCO Model ESFR-17 beam and girder, and so forth) Sprinklers, Is below Branchlines Upright Sprinklers may be used for Where the depths of the solid struc- p g obstruc- quick reference. pPer the requirements of FM,tural members (e.g., beams and stem) tions below upright ESFR Sprinklers The National Fire Protection Associa- exceed 12 inches (302 mm), install can be ignored as follows tion(NFPA)and FM Global(FM Approv- ESFR Sprinklers in each channel als) provide installation standards that formed by the structural members. • open-web bar joists or trusses must be used to properly design an having chords no more than 4 automatic sprinkler system utilizing Ceiling Slope inches(102 mm)wide Early Suppression, Fast Response Maximum 2 inch rise for 12 inch run • bridging or wind bracing no more (ESFR) Sprinklers.The guidelines pro- (16.7/0) than 4 inches(102 mm)wide vided by NFPA and FM Global may Maximum Coverage Area . individuali es and conduit 4 inches differ; consequently, the appropriate 100 ft.2 (9,3 m2) p p standard must be used for a given (102 mm) diameter or less 3 inch installation. In some cases, the installation stan- [DN80] pipe size or less will not dards permit a greater coverage area. require sprigs) In all cases, the appropriate NFPA or Minimum Coverage Area • individual groups of smaller pipe FM Global installation standard must 64 ft.2(5,8 )per or conduit having a total width of 4 be referenced to ensure applicabil- ity and to obtain complete installation NFPA 13/FM Global 2-0 inches or less guidelines, since the following general Maximum Spacing guidelines are not intended to provide 12 feet (3,7 m) for building heights Operation complete installation criteria. up to 30 feet(9,1 m) The fusible link assembly is com- In addition to this technical data sheet, 10 feet (3,1 m) for building heights prised of two link halves that are joined the following data sheets describe greater than 30 feet(9,1 m) together by a thin layer of solder.When other TYCO ESFR Sprinklers: the rated temperature is reached, the - • TFP312 Minimum Spacing 8 feet(2,4 m) solder melts and the two link halves Model ESFR-25 (TY9226) separate, activating the sprinkler and K=25.2 Pendent Sprinkler Minimum Clearance to Commodity flowing water. • TFP315 36 inches(914 mm) Model ESFR-17 (TY7226) NFPA 13 • K=16.8 Pendent Sprinkler Deflector-to-Ceiling Distance 3 to 12 inches(76,2 to 304 mm) • TFP318 Model E.-TR-1 (TY6226) K=14.0 Pendent Sprinkler 1 1 ' TFP316 Page 3 of 4 • Storage Type NFPA FM Global Open Frame(i.e.,no solid shelves) Refer to NFPA 13 Sngle, Double,Multiple-Row,or Portable Rack Storage of Chapters 16 and 17 Refer to FM 2-0 and 8-9 Class I-IV and Group A or B Plastics Solid Pile or Palletized Storage of Refer to NFPA 13 Refer to FM 2-0 and 8-9 Class I-IV and Group A or B Plastics Chapters 14 and 15 Idle Pallet Storage Refer to NFPA 13 Refer to FM 2-0,8-9,and 8-24 Chapter 12 Rubber Tire Storage Refer to NFPA 13 Refer to FM 2-0 and 8-9 Chapter 18 Roll Paper Storage Refer to Chapter 13 (Refer to the standard) Chapter 19 Refer to FM 8 21 Flammable/Ignitable Liquid Storage N/A Refer to FM 7-29 (Refer to the standard) Aerosol Storage N/A N/A (Refer to the standard) Automotive Components in Portable Racks N/A N/A (Control mode only;refer to the standard) N/A—Not Applicable • TABLE A MODEL ESFR-17 UPRIGHT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW Installation Note: Install the Model ESFR-17 Upright Sprinkler in the Upright posi- WRENCH TYCO Model ESFR-17 Early Suppres- tion(Ref. Figure 2). RECESS sion, Fast Response 16.8K Upright Step 1. With pipe thread sealant Sprinklers must be installed in accor- applied,hand-tighten the sprinkler into `AA 44, dance with this section. the sprinkler fitting. Do not apply pres- ) sure to the Link Assembly, and handle 111 General Instructions Avoid damage to the fusible Link the Model ESFR-17 Sprinkler only by Assembly during installation by using the Frame arms. the Frame arms only to handle the Step 2. Wrench-tighten the Model "FITTING SIDE" sprinkler (i.e., do not apply pressure ESFR-17 Upright Sprinkler using only TOWARDS SPRINKLER to the fusible Link Assembly) and by the W-Type 21 Sprinkler Wrench (Ref. FITTING using the appropriate sprinkler wrench. Figure 2)and by fully engaging(seating) FIGURE 2 Failure to do so can lead to an unstable the wrench on the sprinkler wrench W-TYPE 21 link assembly and premature activation flats(Ref. Figure 1). SPRINKLER WRENCH of the sprinkler. Damaged sprinklers Step 3. After installation, inspect the must be replaced. Link Assembly of each Model ESFR-17 A leak-tight 3/4 inch NPT sprinkler Sprinkler for damage. In particular, joint should be obtained by apply- verify that the Link Assembly and Hook ing a minimum-to-maximum torque of are positioned as illustrated in Figure 10 to 20 lbs.-ft. (13,4 to 26,8 Nm). 1, and that the Link Assembly is not Higher levels of torque can distort the bent, creased, or forced out of normal sprinkler inlet with consequent leakage position in any way. Replace damaged or impairment of the sprinkler. sprinklers. • TFP316 Page 4 of 4 Care and Limited Ordering • Maintenance Warranty Procedure TYCO Model ESFR-17 Early Suppres- For warranty terms and conditions,visit Contact your local distributor for avail- sion, Fast Response 16.8K Upright www.tyco-fire.com. ability.When placing an order,indicate Sprinklers must be maintained and ser- the full product name and part number viced in accordance with this section. (P/N). Before closing a fire protection system Sprinkler Assemblies main control valve for maintenance Specify: Model ESFR-17 Early Sup- work on the fire protection system that pression,Fast Response 16.8K Upright it controls,permission to shut down the Sprinklers(TY7126), (specify tempera- affected fire protection system must be ture rating), with Natural Brass finish, obtained from the proper authorities P/N (specify): and notify all personnel who may be 165°F(74°C) P/N 58-447-1-165 affected by this action. 212°F(100°C) P/N 58-447-1-214 Sprinklers which are found to be leaking or exhibiting visible signs of Special Order corrosion must be replaced. Sprinkler Assemblies with Automatic sprinklers must never be ISO 7-1 Thread Connection painted, plated, coated, or other- Specify: Model ESFR-17 Early Sup- wise altered after leaving the factory. pression,Fast Response 16.8K Upright Sprinklers(TY7126)with ISO 7-1 thread Modified sprinklers must be replaced. Sprinklers that have been exposed to connection, (specify temperature corrosive products of combustion, but rating), with Natural Brass finish, P/N (specify): have not operated,should be replaced if they cannot be completely cleaned 165°F(74°C) P/N 58-448-1-165 by wiping the sprinkler with a cloth or 212°F(100°C) P/N 58-448-1-214 by brushing it with a soft bristle brush. Sprinkler Wrench Care must be exercised to avoid Specify: W-Type 21 Sprinkler Wrench, damage to the sprinklers before, P/N 56-001-0-686 during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage,or the like,must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion Section). The owner is responsible for the inspection,testing,and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction.Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. • GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. VICO INCONEL and MONEL are trademark of Special Metals Corporation. VI Fire Protection Products TEFLON is trademark of the DuPont Corporation. Nr:',Ipstarl . • IIII . • ,....,,' •". •....„,,,,,,,,...,..,, EN STOCK: HEAVY WALL, SEAMLESS, STANDARD WALL PIPE, FITTINGS AND FLANGES STEEL PIPE 1 GENERAL DATA s,,,hod,10 10 schock,k,,21.1 di.00 30 Sir.,lizard 0),E,) Sci-m11,03 41) Sct•pciGIJki ei) , :.xtra Strum,' Uroccluf,o 00 Schodukt 100 Salt:104u 120 Sc00,14.00 140 Sr..froG‘io 100 XX St-000 Nifitii ' on 'WT b-....ft WT t...81 WT ., 104.111 1,41T' i#4.ati 'or' f 'toil) Vir ktlft wr / 1011 WT **114 'INT I'..c.ii.111 Vier R*11 WT 1;4ift WI! 1000 VII f •i 1,1,..." 0,405 0.00 4-0 0.r 0.24 1 0.0.3.5; 0',I': il 0;6 0,01 1 1.4 0.5410 ci.o.0 0.33 0,11,.,; 0,43 0401 I 0.43 0.110 i', af<=4 (1,1-.R Q,54 0.8.6 0.055 0.42 11.031 05.- acai 1 05_, 1 0.1116./ a r4 11,126 1004 S ' 1,7 11,8.40 4:418:i 0.67 11.1 CO 065 O.106 1 0,f'.F., 0,14ji 1,4) 0.14U 1,09 4108 1,31 4204 1,132 1'47 •,fif,c.. 0.083 0.88 011 1 1:1 11.11 3 1 1,1S ;6.121 1.48 11.124 1,48 ck-21c, 1.95 0.= 244 1' 7...312 0.1 irJ 1.41 1 0/.1ra 1,60 0138 I 1,f6. 11.1112; 2,1E1 11,10 2.1.17) 0,250 235 .0,35 3,16 1 141'1 -. :6•:.0 0103 1.81 0.1-40 2:2; 0140 2.2.,' ',0.101., 300 0.191 3,00 0263 3,a.-J 0.3,,,"4" 8.22 I iri'l -a.1):•:1 coo1) ,. , ' .14* 2, 2 0,145 2,L2 0.21%1, 30 0,7% 3.63 Lk201 4000,40) ka,,41 ----a 7' 2.n,F, coo •2•..s.a a 0.1 FA 366 01641 3A6 1 0.2161 5.00 0,213 603 O.:144 1.',47, 0,43 404 ?1t2"I 2,1$ 0,1 2.3 3,5,3 ., ._ 1 , - 0..kr,1 540 42(13 I 5,513 0.2E.61 063 0208 Llefil 43105 "0= 4552 13,01 , ..,..' 3.530 4120 4.34 $ 1 0.216 7;t7.,a 02"61 r-.&4.,` 1 0-3001 0.26 0.,":9:4) 10,2,6 '148 -4:34 U')) 1U 3 1,2*I 4,(K)) Cul$5 4.041 0 6•::';',1 14 12 (L22,6 I 8.12 11,3101 12-52 0,310 12,52 0,636 :mho 4' 1 4.500 0.120 .5,52 0.:).1,3 100') 9 20.,.;In * ':1,3j 1200 033;1 1$.00 0.4fc$ 10,0? 4631 72-8.S 07,4 2a5U ,.. 1111 5453 0.134 c..-,13 ' 8.2'48 1443 0250 3443 0 3L5i1.13,60 0:2-5 20,60 0,500 21005 0,625 3240 0,050 30,5g 6" 6.626 0.14 9.30 , 0.2.:',3 16.0f1 02e.(1 1 lii opI - - 1 a.4z24,11 .„7- ; 0 0.432 2640 456? 36.42. 0,r1g 4.54-0 4064 5.3.21 6." 5 8.610 4140 13.41 0250 22.38 0:t00;24Z2 8.322 28.58 4322 20.53 4406 354', 0.6301 43i,43 0400 .1343 0,504 51,00 0,7119 e•Ozo 47,012 672.62 400 E14.E.t. 0.8D5 C2A 10" 110.150 0.165 12.62 0,250 28.05 0.751:.'.'342.. 0.355 40.52 0.265 40.52 asap 54.C.3 1 0.5,30 54.22 0.204 64.40 0.219 cc:10 0.84 4 20.38 1.500 104.23 1.125 1161'..5 1.500 101.23 12' 12.1:20 0.123 24.10 0.250 33.41 0.3364361 0.3.6 40.61 0,405 53.53 0.082 3.22 0.5001 66.42 0ker.0 8.."01 0.344 10242 1.600120.61 1.125 129.21 1.312 160.42 1.030 126,61 14' 1'4.0150 0.223 28..':2; 0.3'2 45.65 0.35l 54.62 0.3.6 54.62 0438 63.50 0.504. 65.13 0.209 czt0 5360 166.23 0.032 130.92 1.061 150.93 1.250 1.10.3'.3 1.409 1105 16' 16.000 '1250 42.00 0312 52.32 0.3-21 62.64 0.3.7s 62.64 0508 22.a.6 0.552 10223 0.2"...0 82.85 1L844 126.844 1.031 164.98 1.219 122.61 1.43B 223.85 1.504 245.42 ... a 12' a ta.cicd) 0260 4,/.44 0.312 58.09 0.428 182.23 0.3.6 .0.65 0.56,2•104.26 0.2,50 100,3,31 0.1.3-)3 e.3.54 0032, lot.03 1.1.02 208.15 1.355 242.:".4 1.552 2,1"4.48 1.2111 30B.E.E.' . .33" 120.003 1125e.:1 62.11a ci3:70 28.5.", 0.5001 04.23 0.3.6 .r.s.fin '1a413232,1 0.212 1104.23.1,031E1.06 1.281 256.34 1.503 206.65 1.C.-Jr0 341.41 1.259 3C.9.52, , ... 22' 22.0136 0250 56.13 013.0 86.59 0.906 "14.02 0.3.6 22.60 02r5 ico.r,3 a.rixi 11.1.02 1.126 221.05 1.2.5 222.48 1.625 253.94 1.8211 403.38 2125 451.49 24' 124/0130 0.250 614:', 0.325 5451 0.562'1.40.61 0.3,6 94.E11 0.6813 gl.C.1.46 0000 1)3IS.. 0.67012.6.61 1213 256.86 1.531 3611CA 1.531 3V,.:44 2.052 433.513 2.344 542.64 t 1 26' :26.0CCi 0312 '8'_,.'''68 0000 136.10 0.3.6 102..2 22' !2a.o3o 0.312 92.35 0.500 146.0-3 8.626122.00 1.1.3.112... a.o214..._6.20 ..0 ',31:1)X0 0.312 04.3.02 fascia 10:.28 0.620 16 .6 0.3.6 118..61 68 i ----:111-4--. - .---- I -4 J ----; ; I 1 32' 1,32.CCO 0312 166.09 0500 16a.31, 0.6:15 20062 0.3.6 1a1./".i 0.208;230.29 0.5.301i166.3C1 _4„.„.. i, I 4 34" i 34.00 0.312 1'2.X. 0550 18.ci8 0i623 222ca 0.3.6 134./0 0.620,240.c0 i 0.0X1/110.08 , .. -14 1"---, 6.000 0.312 110.91 0.600 1202)5 0.625 123622 13.3.6 142ci .21 .c50 2822 a0 1E23.LT 1., t. •.., FireLock EZTM Rigid Coupling ds FM LPCB (Vds) • SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009(UL, FM) STYLE 009V(UL, FM,VdS, LPCB) u EZ Style 009 and Style 009V couplings are rigid, installation-ready couplings for fire protection pipe joining.The couplings unique design eliminates loose parts,insures consis- tent installation and provides substantial gains in productivity. "'" IMPORTANT ''0, 1 FireLock EZ Style 009 and Style 009V couplings are recommended for use ONLY on fire s1'zs`r protection systems. PATENTED STYLE 009 LISTINGS/APPROVALS tt§ The information provided below is based on the latest listing and approval data at the time of publication.Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Pipe Size Pressure Rating psi Pipe Size Pressure Rating-psi Pipe Size Pressure Rating-psi fid.;; tnc73es Ut €,M.,.a Itis.. .Ulx.: f .?:145;!;:!..a44.11 5 11/4-2 175 175 175 EZT 1'/a-2 300 300 300 MT 1'/a-2 300 300 300 10,40 11/4-4 300 300 300 FF 1 1/4 4 300 300 300 MLT 1 1/4 2 300 300 300 BLT 11/4 2 300 300 . 300 FLF 1'/a-4 N/A N/A 300 ST 1'/a 2 N/A N/A 300 DF 11/4 4 300 300 300 FLT 1'/a-2 N/A N/A 300 STF 1'/a-4 N/A N/A 300 DT 11/4 2 300 300 300 FLTL I 1 1/4-2 N/A N/A 300 TF 2%a-4 N/A N/A 300 EF 11/4-4 175 175 175 GL 11/4-2 300 300 300 WLS' 1'/a-2 300 300 300 EL 11/4-2 300 300 300 G5 1%-2 175 175 175 WST! 1'/a-2 : 175 175 175 ET40 11/4 2 300 300 300 G7 j 11/4-2 300 300 300 XL 1%a-2 300 300 300 EZF 3 4 300 300 300 MF 1'/a-4 300 300 300 • STYLE 009V LISTINGS/APPROVALS tt§ Pipe Schedule Size Pressure Rating • mm VdS• LPG: °.:F/6 b. �.F►€ 76.1 mm 16Bar 16 Bar 232 psi 232 psi 11/4-4,76.1mm 16Bar 16Bar 32-100 232 psi 232 psi 1'4 16Bar 20.7 Bar 32 232psi 300 psi 11/2 16Bar 20.7Bar 40 232 psi 300 psi SO 232psi 300psi 3 16Bar 20.7 Bar 80 232psi 300psi 4 16 Bar 20.7Bar 100 232psi 300psi i Listed/Approved for wet and dry pipe systems(>-401/-40"C).For rigid pipe connections in systems operating below 0"F/ 18''C Victaulic recommends Style 005 FireLock rigid couplings with Grade"L"silicone gaskets. 7 Please refer to the Victaulic Field Installation Handbook(I-100)for details concerning when supplemental lubrication is required. §Style 009V couplings are VdS and LPC approved to 16 Bar/232 psi for wet and dry fire protection systems. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved • Date www.vlctaulic.com 1 HF GIC?t.RED TRAftl MARK Of VICTAULIC COMPANY.©2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ,CtaVl1C R E'J H 10.60_1 7111 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.60 FireLock EZTM Rigid Coupling • STYLE 009(UL, FM) STYLE 009V(UL, FM,VdS, LPCB) STYLE 009 DIMENSIONS Max. Max. Allow. Work. End Pipe End @ Bolt/Nut Aprx. Size Press.* Load* Sep.t No.-Size g Dimensions-Inches/1nm Wgt.Ea. . Y 0 t Z Nominal �Outsidk , i, :1-,-". �� a�a� 3A �� �c` Old � L yr` �A -..:I.'-',,,, .4...-::' � 1 � 1: a - ,■ :-------N.1, a`',t.!1 ., ?� ,�.. . . . w�. ... iaa.._ .mss:. > Ti ►'-P° 1' 1.660 300 649 0.10 3.13 4.93 2.89 4.83 1.93 15 _k - _ illIC 42.4 2068 2888 2.54 2-'/s x 2 80 125 73 123 49 0.7 - 1 1/2 _-< 1.900 300 851 0.10 2-'/x 2 3.38 5.16 3.11 5.07 1.86 1.7 40 48.3 2068 3787 2.54 86 131 79 129 47 0.8 STYLE 009 PRE-ASSEMBLED 2 2.375 300 1329 0.12 2-'/e x 2 Y 3.88 5.81 3.59 5.68 1.86 1.9 (STAB IN CONDITION) 50 60.3 2068 5914 3.05 99 148 91 144 47 0.9 2' 1 2.875 300 1948 0.122-/e x 2%: 4.38 6.21 4.08 6.10 1.87 2.0 4-----y > .-Z->I 65 : 73.0 2068 8668 3.05 r 111 158 104 155 48 0.9 3 1 3.500 300 2886 0.12 „ 5.06 6.68 4.73 6.43 1.90 4.3 ��\ 80 88.9 2068 12842 3.05 2 / x 2/z 129 170 120 163 48 2.0 kI up �j. x lr� 4 4.500 300 4771 0.17 2-V, x 2 7 6.46 8.64 6.00 8.34 2.10 2.3 - 100 114.3 2068 21230 4.32 164 220 152 212 53 1.0 /. '@ t Refer to notes below. STYLE 009 JOINT ASSEMBLED STYLE 009V DIMENSIONS Max. Max. Allow. Work. End Pipe End Cv Bolt/Nut Aprx. Size Press.* Load* Sep.t No.-Size Dimensions-Inches/mm Wgt.Ea. Aet dt L ...l...,:!...^ tltiiYe n, Y 0I ',,7 0 E47!„,64.14t,„,mow.siortioiialitar ,,,,, ,,,,,,.:44.4c.:iiim,.., ,, ,,,,,,3e.,i4,.;: n„.!,,,,,,,,,..„,„,t,„2„..t.tf,,,,,... 4* .....aza,;.,46mte,14.....,..4 Iii, "-\ .:, � .. - *0"` �F h C ry .... F �Y 1k .ems mm ' m a ixmv "leis:s � �S - "J� 1'14 1.660 300 649 0.10 3.14 4.84 2.85 4.65 - 1.91 1.6 - 0 a /.-. pll� 32 42.4 2068 - 2888 2.54 2-M10 x 57 80 123 72 118 49 0.7 ��✓ � 11/2 I 1.900 300 851 0.10 2-M10 x 57 3.34 5.06 3.13 4.85 1.92 1.7 40 i 48.3 2068 3787 2.54 85 129 80 123 49 0.8 STYLE 009 PRE-ASSEMBLED 2 I 2.375 300 1329 0.12 2-M10 x 64 3.91 5.66 3.61 5.47 1.94 2.1 (STAB IN CONDITION) 50 E 60.3 2068 5914 3.05 99 144 92 139 49 0.9 761mm 3.000 300 1948 0.12 4.57 6.46 4.17 6.18 1.96 2.3 _ _Y__ r 2-M10 x64 .-Z-> 76.1 2068 8668 3.05 116 164 106 157 50 1.1 3 . 3.500 300 2886 0.12 5.15 712 4.73 6.67 1.94 2.6 7; / ':, \ 2-M10 x64 el 80 88.9 2068 12842 3.05 131 181 120 169 49 2 _ �ii J .,I 4 4500 300 4771 0.17 6.39 8.74 6.05 846 2.11 4.6 - c _ 100 114.3 2068 21230 4.322-M1064 162 222 154 215 54 2.1 • . * Working Pressure and End Load are total,from all internal and external loads, based on STYLE 009 JOINT ASSEMBLED standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See pages 3 and 4 of this document for Listed/Approved ratings on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. Q Number of bolts required equals number of housing segments. • www.victaulic.com ictauLc" . , , ,",1 FRED TRADEMARK 01 VICTAULIC COMPANY.©2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. -„,>, 10.60_2 REV_H p. IPS CARBON STEEL PIPE—FIRE PROTECTION PRODUCTS 10.60 FireLock EZTM Rigid Coupling • STYLE 009(UL, FM) STYLE 009V(UL, FM,VdS, LPCB) MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Housing Coating: • Orange enamel(North America) • Red enamel(Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade"E"EPDM(Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. • www..,ictaulic.com TRADEMARK OF VICTAULIC COMPANY.©2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. .Ctaullc REV H 10.603 Ct,. «_. _ .. xf;, FireLock EZTM Rigid Coupling STYLE 009(UL, FM) • STYLE 009V(UL, FM,VdS, LPCB) GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.corn. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • 11111111111111111111111011111111 WCAS-78KHHG • For complete contact information,visit www.victaulic.com / 10.60 3999 REV H UPDATED 11/2007 V ictaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA 10.60 FireLock® Fittings O FM ® LPCB VdSIVNIIPO • I See Victaulic publ�catron 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services.FireLock full-flow elbows and tees feature CAD-developed,hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services.Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. [ MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-I. • • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved • Date www.victaulic.com \iCtauluc V ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. -..N REVI 10.03_1 '"nl , • IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings • DIMENSIONS CtoE I -9 i to_,,i Il CtoE 0 _ 0- toE .= I J '° L t L o o l j I-� \1J NO.001 NO.003 NO.002 NO.006 No.001 No.003 No.002 No.006 i. �% '-Size 90°Elbow 45°Elbow Straight Tee Cap lii II i u . l ,,, g a t v., 1.660 0.8 0.3 32 42.421 0.1 11/2 1.900 - -..... .........082 04_ 40 48.3 - - - - - 21 0.2 2 2.375. ... 2.75 1.7 ......._200 1.8....... 2.75 2.4.. 0.88 0.6............ 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2' 2.875 3.00 . 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000....._ ........3.00 3.30...... ........225 2.4....... _.... _._.... 76.1 76 1.5 57 1.1 _.__ 3 3.500...... ......3.38 40......... ......_250 31........ .........338 5.3__. .........088 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7....... .........300 5.1.. . .........400 7.5.... 108.0 102 2.6 76 2.3 102 3.4 4 4500 4D0 60 32.5 4.00 8.7 00 24 100 114.3 102 3.0 76 2.5 102 3.9 25 i.' 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 • 125 141.3 124 5.7 83 - 3.8 124 7.1 25 1.9 159 mm 6.250 5.50 12.6 3.50 - 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625...... ...550 18.3....... ..._._350 11.7_. ._._..550 22.7..._ .._.._100 5.9.... 150 168.3 140 8.3 89 - 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 - 20.4 6.94 38.7 113 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 ' . • www.victaulic.com vctVIC IAi,11C ISA RI"I ST ER ED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. -„- __ ,, REV_I II IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA Frictional Resistance Size Equivalent Feet/meters of Straight Pipe t Nominal a Outs[de Elbows • �€4k min inches- 4e a Ni)::001' a • : z_Elbor ... Run 1'/4 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 h '. 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2' 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 - 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159 mm 6.250 9.4 _....... 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 2191 4.0 1.5 10.1 4.0 • T The flow data listed is based upon the pressure drop of Schedule 40 pipe. • www.vict3ulic.com • 41-'1ERtD TRADEMARK CO VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.AIL RIGHTS RESERVED. Icit.aull..' 001 ; 10.03_3 J 8 FireLock® Fittings • GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. .................. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • • • a For complete contact information,visit www.victaulic.com _ / 10.03 1539 REV I UPDATED 2/2010 V 1ctaullc vC IAEA Ir; A III'TITTERED TRADEMARK OF VICIAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED -- - -- 10.03 0 ,I . tyro Worldwide • Fire Protection Contacts www.tyco-fire.com Products Model BFV-N Butterfly Valve Grooved End 2-1/2 to 10 Inch (DN65 to DN250) General Technical Description Data The Model BFV-N Grooved End But- Approvals _t: o terfly Valves(Ref. Figure 1)are indicat- UL and C-UL Listed ing type valves designed for use in fire FM Approved protection systems where a visual in- dication is required as to whether the Listed by California State Fire Marshall valve is open or closed.They are used, under Listing No.7770-1670:100 for example, as system,sectional,and All laboratory listings and approvals are + ` pump water control valves.They have for indoor and outdoor use. ' cut groove inlet and outlet connections that are suitable for use with grooved Maximum Working Pressure end pipe couplings that are listed and 2-1/2 to 8 Inch(DN65 to DN200) approved for fire protection systems. 300 psi(20,7)bar For applications requiring supervision 10 Inch(DN250) of the open position of the valve, the 175 psi(12,0 bar) Gear Operators for the Model BFV-N Materials of Construction Butterfly Valves are provided with • two sets of factory installed inter- Body nal switches each having SPDT con- Ductile iron conforming to ASTM A395 tacts (Ref. Figure 3). The supervisory Body Coating switches transfer their electrical con- Polyamide tacts when there is movement from the valve's normal open position dur- Disc ing the first two revolutions of the Ductile iron conforming to ASTM A395 handwheel. Disc Seal NOTICE Grade EPDM "E" encapsulated rubber conforming to ASTM D2000 The Model BFV-N Grooved End But Upper&Lower Stem terfly Valves described herein must Type 416 Stainless Steel conforming to be installed and maintained in corn- ASTM 582 pliance with this document, as well as with the applicable standards of the Lower Plug National Fire Protection Association,in PVC addition to the standards of any other Operator authorities having jurisdiction. Failure to do so may impair the performance Gear operator with iron housing of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. • Page 1 of 4 JANUARY 2015 TFP151O 7 TFP1510 Page 2 of 4 • Nominal Nominal Installation Dimensions Valve OD Inches(mm) Weight Sizes Inches Lbs. Inches (mm) A B C D E F G H (kg) (DN) 2-1/2 2.88 3.85 11.94 3.25 5.67 5.90 5.82 2.13 0 22 (65) (73,0) (98,0) (303,3) (83,0) (144,0) (149,9) (147,8) (54,1) (10,0) 3 3.50 3.85 12.48 3.54 5.94 5.90 5.82 2.13 0 23 (80) (88,9) (98,0) (317,0) (90,0) (150,9) (149,9) (147,8) (54,1) (10,4) 4 4.50 4.56 14.18 4.35 6.31 5.90 7.64 2.13 28 (100) (114,3) (116,0) (360,2) (110,0) (160,3) (149,9) (194,1) (54,1) 0 (12,7) 5 5.56 5.86 15.17 4.84 7.32 5.90 7.64 2.13 0 31 (125) (141,3) (149,0) (385,3) (123,0) (185,9) (149,9) (194,1) (54,1) (14,1) 6 6.63 5.86 17.54 5.93 8.62 5.90 7.64 2.13 0.67 41 (150) (168,3) (149,0) (445,5) (151,0) (218,9) (149,9) (194,1) (54,1) (17,0) (18,6) 8 8.63 5.26 19.42 6.87 9.80 9.80 7.91 2.13 5.86 53 (200) (219,1) (134,0) (493,3) (174,0) (248,9) (248,9) (200,9) (54,1) (148,8) (24,1) 10 10.75 6.29 24.03 9.17 11.61 18.00 9.49 3.03 7.41 88 (250) (273,1) (160,0) (610,4) (233,0) (294,9) (457,2) (241,0) (77,0) (188,2) (40,0) INDICATOR G F 1 HANDWHEEL FLAG / 1/2"NPT CONDUIT CONNECTION GEAR 1 OPERATOR ^ • E O I BODY BJ / , D,: )___DISC • H ( , — —A— FIGURE 1 MODEL BFV-N GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS Installation switch is intended for connection to the supervisory circuit of a fire alarm The Model BFV-N Grooved End But- control panel in accordance with NFPA terfly Valves may be installed with flow 72.The auxiliary switch is intended for *11 in either direction and can be posi- the unsupervised connection to aux- � tioned either horizontally or vertically. iliary equipment in accordance with 'ttl NFPA 70,National Electric Code. A C / The grooved end pipe couplings used \/_..„„,,, with the Model BFV-N must be listed NOTE: For outdoor applications with A P or approved for fire protection service internal supervisory switches, it is rec- OPEN B - -- and and installed in accordance with the ommended that wiring connections manufacturers instructions. be made at a temperature above 15°F (-9°C),in order to insure sufficient flex- A SHUT The Model BFV-N Butterfly Valve may ibility of the wire lead insulation. be installed with any schedule of pres- FIGURE 2 sure class of pipe or tubing that is list- Stop Adjustment MODEL BFV-N GROOVED END ed or approved for fire protection. Procedure BUTTERFLY VALVE . As applicable, refer to Figure 3 for the The gear operator's OPEN and SHUT OPERATOR ADJUSTMENT internal switch wiring diagram. position have been factory set. The Step 2. Remove two lockscrews (A) following procedure should be used if from the gear operator body. Conduit and electrical connections slight adjustments are needed. Refer are to be made in accordance with to Figure 2. Step 3. Turn the Shut Stop Screw (B) • the authority having jurisdiction and/ Step 1. Turn the Handwheel until the clockwise until snug. or the National Electrical Code. With valve is fully closed. Step 4. Turn the Handwheel until the reference to Figure 3, the supervisory valve is fully open. LL r ' TFP151O Page 3 of 4 • FLOW RATE IN LITRES PER MINUTE(LPM) (1 GPM=3,785 LPM) 300 400 600 1000 2000 4000 6000 10000 20000 40000 5.0 I Ill! mu' 4i11LJ!mu u1)1/U 1 111 illlll UUI I11 J111 I 11„1 J 1 ll 1 lilil Ilii_ 4.0 —0,30 3.0 -0,20 2.0 1n a a m o1 . . =0,10 Z fr U - 0? =0,08 OQ w w 1.0 I4--o / o 0 0 - CC CO n ;; 0/ i, . ?U�� gyp/ `O `O. p= ,c0 ?G =V� �V� SVT. " a h 0• a� z2' 0.4 - 003 <a CI- 0.3 ' / 7// zyy, =0,02 O 0.2 / =0,01 0.1 _ 60 100 200 400 600 1000 2000 4000 6000 10000 15000 • FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A DN65 THROUGH DN250 MODEL BFV-N BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW r -, r 1 1- SUPERVISORY 41 I— AUXILIARY CONTACT RATING: SWITCH GND SWITCH 1,2','i 12.7,VDC • 114A cs,1 250 VDC SWITCH SHOWN SWITCH SHOWN 15.1A/12HP Q 125,250 VAC WITH VALVE WITH VALVE 5A @ 125 VAC"L" `- --- -- --- -J FULL OPEN J FULL OPEN WW z C7 C7 F Q W Z z 0 w J J J Q Q CC Q = J W W CC CD 5 m >- >- o O O 1 • +_____(--\__, BELL END OF LINE PANEL RESISTOR POWER • + FIGURE 3 MODEL BFV-N BUTTERFLY VALVE INTERNAL SWITCH WIRING DIAGRAM WITH VALVE IN OPEN POSITION Step 5.Turn the Open Stop Screw(C) Step 7. Replace two lockscrews (A) clockwise until snug. into the gear Operator body locking Step 6. Close the valve by turning the the stops into position. Handwheel until the valve is fully in the closed position. Ensure the disc has returned to the fully closed position and the disc is centered in the seat ID area. Readjust the Shut Stop Screw if necessary. TFP1510 Page 4 of 4 Care and Limited • Maintenance Warranty Before closing a fire protection sys- For warranty terms and conditions, tern control valve for maintenance or visit www.tyco-fire.com. inspection work on either the valve or fire protection system which it con- Ordering trols, permission to shut down the af- fected fire protection systems must be Procedure obtained from the proper authorities and all personnel who may be affected Grooved End Butterfly Valves by this decision must be notified. Specify:(specify inch size)Model BFV- The owner is responsible for the in- N Grooved End Butterfly Valve with spection, testing, and maintenance internal supervisory switches, P/N of their fire protection system and de- (specify) vices in accordance with the appli- Valve Size Valve Part Number cable standards of the National Fire Protection Association (e.g., NFPA 2-1/2 59-300-F-025N 25), in addition to the standards of 3 59-300-F-030N 59-300-F-040N any authority having jurisdiction. 5 59-300-F-050N Contact the installing contractor or 6 59-300-F-060N product manufacturer with any ques a 59-300-F-080N tions.Any impairment must be imme- diately corrected. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified in- spection service. • • GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. fico `f Fire Protection Products VSR P POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,CUL and CSFM Listed,FM Approved,LPCBApproved,For CE Marked(EN12259-5)/VdS Approved model use VSR-EU Service Pressure: 450 PSI(31 BAR)-UL Flow Sensitivity Range for Signal: 4-IOGPM(15-38LPM)-UL Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250VAC 2.0 Amps at30VDC Resistive 10 mAmps min.at 24VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-I 3R Nominal Pipe Size Model Part Number National Fire Alarm Code NFPA-72 2" DN50 VSR-2 1144402• 2 I/,.. DN65 VSR-2 1/21144425 3" DN80 VSR-3 1144403 • Installation must be performed by qualified personnel and in 3 1/2" VSR-3 1/2 1144435 accordance with all national and local codes and ordinances. • Shock hazard.Disconnect power source before servicing. Serious 4" DN100 VSR-4 1144404 injury or death could result. 5" - VSR-5 1144405 • Risk of explosion.Not for use in hazardous locations. Serious 6" DNI50 VSR-6 1144406 injury or death could result. 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit,stock no.0090148 CAUTION Replaceable Components:Retard/Switch Assembly,stock no. 1029030 Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air,or short retard times. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed and FM Approved for use on steel pipe; die-cast housing. The cover is held in place with two tamper resistant schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 mm). LPC screws which require a special key for removal. A field installable approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering cover tamper switch is available as an option which may be used Information chart. to indicate unauthorized removal of the cover. See bulletin number The VSR may also be used as a sectional waterllow detector on large 5401103 for installation instructions of this switch. systems.The VSR contains two single pole,double throw,snap action switches and an adjustable,instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. . Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV L PAGE I OF 4 3/09 791Ir VSR P J VANE TYPE WATERFLOW . -'® The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. I) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6"(15 cm)of a fitting which changes the direction of the waterflow or within 24" (60 cm)of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole.Roll the vane so that it may be inserted into the hole;do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfow.Take care not to damage the non-corrosive bushing in the saddle.The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. I).The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty. Fig.1 Retard Adjustment DO NOT LEAVE COVER OFF FOR I i/� AN EATENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 11. -t % ✓ 0 to the max setting(60-90 seconds).The time delay should be set at <11.1*- , Ii•i'= ! the minimum required to prevent false alarms (� �� TIGHTEN NUTS \\�) f'0 ill /1 ,;-0 ALTERNATELY �,. 0, u - / CAUTION �,rl'' ' Hole must be drilled perpendicular to the pipe and vertically centered. 11,14401...47-40011kRefer to the Compatible Pipe/Installation Requirements chart for size. � Correct Incorrect Ili MOUNT ON PIPE SO ARROW SADDLE iN IPOINTS IN DIRECTION •IWO_ OF WATERFLOW ONLOW III\\\ 0 1 _ - \\\ ,...,......_j e ...mg... ROLL PADDLE IN1 ........... 9. g 911 TEOPPOSITE DIRECTION ADAPR DIRECTION OF OF WATERFLOW WATERFLOW \ (Dw& tig hater aeti rates 20111111*21111 MAX. device in one direction only) DNS()ONLY iV USE 1215 IR016'-ADAPTERS AS SHOWN ABOVE DWG lld6-Il Compatible Pipe/Installation Requirements Model Nominal Pipe Nominal Pipe Pipe Wall Thickness I tote Size U-Bolt Nuts Size O.D. Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch mm inch mm inch mm inch mm inch inm inch mm fl-lb min VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - 125+.125/-.062 33.0+2.0 VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - 20 27 - VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 2.00+.125 50.8+2.0 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 • NOTE:For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MEG.#5401146-REV I. PAGE 2 OF 4 3/09 .4. if - PVSR • . PO VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping To remove knockouts:Place screwdriver at Break out thin section of cover when Plate Terminal inside edge of knockouts,not in the center. wiring both switches from one conduit entrance. ,/ ed �Si NG�� U DWG #1146-16 I ��� �•� h 0:,>t, An uninsulated section of a single conductor should not be looped 1 / \ ��1�.I�`I� around the terminal and serve as two separate connections. The ,`� �� ��� wire must be severed,thereby providing supervision of the �� •�:' ` connection in the event that the wire become dislodged from under NOTICE \ /, the terminal. Failure to sever the wire may render the device Do not drill into the base as this creates t`. oda 1146-13 inoperable risking severe property damage and loss of life. 45 metal shavings which can create Do not strip wire beyond 3/8"of length or expose an uninsulated electrical hazards and damage the . conductor beyond the edge of the terminal block.When using device.Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. Fig.5 Typical Electrical Connections 111.111 r • NI Notes: ® Ii i 1.2-4POWER SOURCE1. The Model VSR has two switches,one can be used to operate a central r III SUITABLE FOR BELL _,ratio❑ ,aopnetary or remote signaling unit,while the other contact — I ■i' _ '%+'', NIk i • is used tooperate a local audible or visual annunciator. / _ Cll ' hili■--.,_ �� 111 Win. It �u iii 2. A condition of LPC Approval of this product is that the electrical 1_ - �■I 'i • • • entry must be sealed to exclude moisture. _ '±', ��� WATERFLOW ZONE 3. For supervised circuits,see"Switch Terminal Connections" _ _ �`� �±;,, IDEOLR ON FIRE PANEL i -, drawingand warningnote(Fig.4). ® +, ODA.114432 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve shall always be used for test purposes.If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR is not recommended or advisable. A minimum flow of 10 GPM(38 LPM)is required to activate this device. NOTICE Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig.7 Mounting Dimensions 51 2 2m Fig. 3.50 in (141. mm)—' (89.0 mm)-*: 2.00 in GREEN GROUND 14- (508 mm) k SCREWS 2.34 in r i III ° A (59.4 mm) � Q1 ilN PIPE DIA. U-BOLT NUT NMI +5.25 in �� ��� 133.4 mm) ff]I/ri` ISI I I Ira .m• U-BOLT WASHER �� �� ( PIPE SADDLEiff IN 1'4. j©�(17LTlti,- C)I R �." key PIPE �� }�'�il�Inl�j!� Q 010, .../ El DWG IH6-It , .�. Y I PLASTIC PADDLE1,1 i,i i,i � `� • U-BOLT NOMINAL PIPE DIA.+1.75 in(+44.5 MM)FOR DN 50-DN 65 2-2.5 inovc 1146-13NOMINAL PIPE DIA.+2.125 in(+54.0 MM)FOR DN 80-DN 200 3-8 in PRINTED IN USA MFG.#5401146-REV L PAGE 3 OF 4 3/09 .N" it VSR VANE TYPE WATERFLOW • The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig.6).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig.6) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell(if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the(2)mounting screws holding retard/switch assembly to the base.Do not remove the(2)retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig.6 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE i i BREAKOUTTHIN SECTION OFCOVER WHEN WIRING BOTH SWI'I CHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING I CREWS RETARD,SWITCH ASSEMBLY 1111111116110;- • .11 , armI l;;h SiIr (2)LOCATING PINS F � -� (2)LOCATING PIN DO NOT REMOVE I .��:, BOSSES IN BASE (2)RETARD HOUSING qI _ SCREWS rI• � �II MI= III� 1II1 _- dip Jr 7 .o. ,. IIV ,, BAS Nallao pc)" � ,v,. DWG#1146-10 Removal of Waterflow Switch • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. • Lift detector clear of pipe. • PRINTED IN USA MFG.#5401146-REV L PAGE 4 OF 4 3/09 I • gg P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH 3111k. 44. • SIZE-ROD: 3/8" SIZE-SYSTEM PIPE: 4"max. SIZE-ROD: 1/2" SIZE-SYSTEM PIPE: 8"max. MATERIAL-Ductile iron. FINISH-Plain,E.G. and H.D.G. LISTING/APPROVAL- `®"s203-EX 2551 FM FM Approved NE FUNCTION-Attachment component of an AFCON hanger. 1.4To support horizontal piping.INSTALLATION- Per NFPA 13 and these instructions. Install on steel flange-thickness less than 3/4". Set bolt up or down. ASSEMBLY/ATTACHMENT-See drawing. Torque-3/8"=60 inch lbs.or 1/2"= 125 inch lbs. In the absence of a torque wrench,engage set bolt finger tight then additionally tighten 1/4 turn. Caution-Do not over tighten set bolt. _ FEATURES * Maintains CONSTANT HANGER CENTER-LINE,with set bolt up or down. * Flat throat back to prevent twisting on structure during installation. ORDERING-Part#,rod size and finish. • 11/09 • 9OZ7 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 UNIVERSAL RESTRAINING STRAP Nut optional, if insufficient rod dimension / il, L F2.. ,t IA • I SIZE-One size fits both 3/8"and 1/2"rod or set screw. Available lengths 4"and longer. MATERIAL-Carbon Steel. i !NISI I -N111. Galvanized. LISTINGS- cus 203-EX 2551 PATENT-No.5,897,088 = '_' FUNCTION-To enhance hanger attachment in areas subject to ��� Earthquakes. INSTALLATION-Install tight to structure and component parts Minimum return on strap: I" L-dimension is measured from hanger rod center a to the strap end. FEATURES *Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings _„�_, provided) - ORDERING-Part#and L-dimension. ! • la. J 1/08 • P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER • 1 thru 4 inch pipe 1/2&3/4 inch pipe LISTED FOR STEEL/CPVC 5 thru 8 inch pipe NFPA 13 UL 1 WT. 5 WT.*250 TEST PIPE ROD LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 SIZE-ROD-3/8"or 1/2" 2 3/8 76.95 634.75 750 SIZE-SYSTEM PIPE- 1/2" thru 8" 21/2 3/8 118.35 841.75 850 MATERIAL-Carbon Steel,Mil.Galvanized to G-90 spec. 3 3/8 162.30 1061.50 1050 LISTING/APPROVAL- 4 3/8 246.00 1480.00 1500 cOes 5 1/2 349.45 1996.75 2000 LISTED 203-EX 2551 1"-8" 6 1/2 476 35 2631 75 2650 O n 8 1/2 711.00 3805.00 4050 FM Approval guide-1"-8" PP OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E,Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe hanger component of an AFCON hanger. To support steel,CPVC or copper pipe. INSTALLATION-Per NFPA 13, 13R, 13D,these instructions and PIPE A 8 the CPVC or copper pipe manufacturers instructions. ir1 1.8793 2.5259 FEATURES = "'° 2,382 27650 * 1112 22673 29140 • Sized and listed exclusively for use with#310 Surge Restrainer. 13 2 26048 32516 * Band edge is offset for EASY pipe insertion. / A 21/2 34520 41150 * Custom fit swivel nut for better retention in ring. V<. -3 . 97845 4431 ORDERING-Part#,pipe size. + ` 4958Y 49992 6 6.0668 6.8180 • 8 75768 83290 11/09 • �00� P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 001/020 SWAY BRACE FITTING MODEL E Part#077 C3:41,11 IN"• 1"min. ik, Horizontal Load Ratings • SIZE-SYSTEM PIPE: Nominal Size " Sch.10 Sch.40 Steel 1"thru 4" Sch. 10 and Sch.40 1 250 1000 SIZE-BRACE PIPE: 1"or 1 1/4"Sch.40 1 1/2 250 1000 MATERIAL-Carbon Steel or S.S.(Type 304). 2 1noo 1300 FINISH 21/2 800 1300 Plain or E.G. 3 Boo 1-inn LISTING/APPROVAL- 4 800 1500 <>FM Approved-1950 OSHPD OPA-0601-07 See Website. FUNCTION- Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION-Per these instructions including NFPA 13 and 13R. Load rating-see chart. Align brace pipe perpendicular to system pipe. ASSEMBLY-See drawing. Combine with proper AFCON components-see disclaimer below. Insert brace pipe through rod bend and under channel bracket to achieve minimum 1"extension. Tighten hex nuts until gage spring lays flat and torque to 165 in.-lbs. FEATURES *Visual inspection,verifies proper installation. ORDERING-Part#,size-system pipe,size-brace pipe and finish. S Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners.resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by.IFCO.N.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect.incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-.4FCO:N products have been.or are used. 5/12 • .g000 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32" 17/32" I 111%11111Tmoi error• SIZE-BRACE PIPE: I" and 1 1/4" Sch.40 MATERIAL-Carbon Steel,Ductile Iron or S.S.(Type 304). FINISH-Plain or E.G. LISTING/APPROVAL- c QL N usno 203A-EX2625 .C>FM Approved- 1950 OSHPD OPA-0601-07 See Website. Horizontal Load Ratings Base eq FUNCTION-Structure attachment fitting of an AFCON sway brace assembly. Material Ffn LISTED Sway brace assemblies are intended to be installed in accordance with Ductile 1500 2015 NFPA 13 and the manufacturer's installation instructions. Steel --- 2015 INSTALLATION-Per these instructions including NFPA 13 and 13R. Load rating-see chart. Install fasteners in accordance with NFPA 13. ASSEMBLY Combine with proper AFCON components-see disclaimer below. Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * Swivel allows attachment at any angle. *Visual inspection,verifies proper installation. * Larger fastener hole available.-Consult factory. • ORDERING-Part#,pipe size and finish. Specific IFCON products are exclusively designed to be compatible ONLY with other.1FCO.Y produce.including parts and fasteners,resulting in a listed sway brag,restrainer or hanger assembly. • Be advised the following warranty restriction will apply. DISCLAIMER-,IFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by FCO,V AFCON shall NOT be liable under ally circumstances whatsoever for any direct or indirect.incidental or consequential damages of any kind.including but not limited to loss of business or profit,when non-AFCON products have been,or are used. I I/1 I ts;.•''ate. i ..4e47grig 00 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 086 SWAY BRACE ADAPTER ,l •e ,s9SIZE-SYSTEM PIPE: See Chart. �L 0' MATERIAL-Carbon Steel. FINNlt - f H': nr E.G. • I'.-\I E:\f- No.6,334,285 LISTING/APPROVAL- cam 203A-EX 2625,203-EX 2551 ror LISTED <>. FM Approved-1950 OSHPD See Website FUNCTION-Sway brace adapter for an AFCON sway brace assembly. %mom 'a_ ; AN Designed to attach to the horizontal flanges of a steel structural member. Sway brace assemblies are intended to be installed in accordance with =_ 4 NFPA 13 and the manufacturer's installation instructions. Additionally listed as an 8"hanger attachment. PaiM07 INSTALLATION-Per NFPA 13 and these instructions. Load rating-see chart. Combine with proper A FCON components-see disclaimer below. The stnictural members design will dictate specific attachment criteria. `11 ASSEMBLY- See drawing. Ili II IlI1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII �VIII pip Insert 1/2"x 1 1/4"attachment bolt in 086 bracket.Install 1/2" studs that both cm 0, brackets and engage on steel flange. Install nuts on studs linger tight,then additionally tighten 1 1/2 turns or torque to 40 lb-ft. Part0O77 Attach AFCON sway brace assembly on 1/2"bolt. ', *Studs,fasteners and bolt Jurnished by customer Load Ratings E UL 0r Max.Pipe MED FEATURES Parallel 300 thru 90° 1265 4" * Fits 1/4" thru 1 1/4" flange thickness. Perpendicular 30°thru 90° 2015 8" • * Studs capture head of bolt,providing hold back. *Alternative to center loading beam clamp. Load Ratings FM ORDERING-Part#and finish. Parallel 30°thru 90° CLICK Perpendicular 30°thru 90° HERE • Speci tic A FCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be ads ised the following warranty restriction will apply. DISCLAIMER-AFCOY will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCO.Y.A FCO\'shall NOT he liable under any circumstances whalsoeeer tot any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit-when non,I FCO Y products hate been.or are used. 2/13 • • '� • gg P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING Part#077 INA...till ifiliiMr Air 0 `� \ Part#078 4 ri-1 r - Part#410 — 1116. J I ° . `' all SIZE-SYSTEM PIPE:Nominal Pipe Size Sch.40 Steel 1" thru 8" Sch.10 Steel 1 1/4"thru 8" MATERIAL-Carbon Steel Horizontal Load Ratings FINISH-Plain or E.G. LISTING/APPROVAL- Size UL 1"-4" 1000 c4� u 203A-EX 2625 6"-8" 2015 `"E° 203-EX 2551 (4"-8"Only) Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION-Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION- Per NFPA 13 and these instructions. Load rating-see chart. Align brace pipe parallel to system pipe. ASSEMBLY-See drawing. Combine with proper A FCON components. Tighten bolts to minimum required torque of 40 ft. lbs. 078 is a preferred assembly component. ORDERING-Part#,pipe size and finish. • , , , , . Specific AFCON products arc exclusively designed to be compatible ONLY with other,IFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be ads is,d the following warranty restriction will apply. DISCLAIMER-.JFCON will NOT warrant againstfothe failure of its products when used in combination with other products.parts or systems dn ::_' r:d or sold by.AFCON..4 FCON shall NOT be liable under any circumstances whatsoever r any direct or indirect.incidental or consequential damages of any kind.including but not I..w:rim ........ .........t profit,when non-.-I FCON products have been,or are used. 7/11