Loading...
Report (32) s1 S= poi/L/ ZOOS Sw tfz n2/kr, s.44x; -06 TIGARD .)c‘" DISTRIBUTION1' CETNER 8005 SW HUNZINKER RD TIGARD, OR 97223 FIRE ALARM DATASHEETS Prepared by Fire Systems West, Inc. Phone 360.693.9906 For Jet Industries 503.363.2334 lg. 1. • r, R • r U amj • { �. ° ::.ark - Nt' ......_ IE ,, SANNunne�erSt ` •::: P ik:i .F t� . '< 0.•'�` ' ::201 5 Gocg'.e _ *ii,,„ (;()()((isl�' ,a.t1 ! ice, „:, SCOPE OF WORK: New spriknler monitor panel with cellular DACT. 101 SILENT Intelliknight® Model 5820XL KNIGHT Addressable Fire Alarm Control System by Honeywell Y The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface -- ::: ,r, module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • • Built-in synchronization for appliances from AMSECO®, 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging capacity of 35 amp hours (An additional cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel • Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure (PN RBB) is required programming.You u can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows®_ supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs,or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non- digital communicator for remote alarm, trouble or supervisory condition twisted, unshielded cable when wired reporting of system activity and system has been silenced but not yet cleared in compliance with standard wiring programming.The communicator has System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility.The communicator cables. No special wiring is required. supervises two phone lines and will System Application 5820XL provides 13 preset notification activate a trouble signal if a line failure cadencepatterns (includingANSI 3.41) is sustained for more than 45 seconds. 5820XL has one built-in signalling line Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used. Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco The 5820XL SLC loops support Additionally, the IntelliKnight system Contact ID. The format is selectable by features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector User Interface - -." • Addressable heat sensor The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large ,...., I S 4 6 • Contact module easy-to-use tactile touchpad can be M '0 '0 Q rn, Io • Relay output module used for system operation, r ri ,; programming and maintenance. It has . ,, r • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history protocol• only) Signalling; Local Protective Signalling buffer stores 1000 events for viewing Systems;Auxiliary Protected Premises The following advanced sensor from the built-in or remote annunciator. Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual, waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. P supervisory(DACT non-coded) • Maintenance alert signalling Programming 9 9 services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed requirements P P fY P up CSFM 7170 0559: 135; programming. The JumpStart®feature MEA 429-92-E Vol. VI; FM Approved minimizes programming 1 IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL Wedelns sed Facility Addressable Fire Alarm System Management Software SK(System Sensor) Protocol Devices V\Indows Based UptOownload Software iI 2 I vts Compatible CS r C. Receiver r:....a utomat on 0Software t . Internet • iiiw 5820XL SK-2I2Uc Connection VisorAlarm i 1. IP Communicator 5895XL ► Irralipslt Paw Module 3 Form C Relays i 4 3 Fn" C Rdaya I ' 1111 &eSFt PdrlI . Parallel a.e 5815XLen -8 Rsx32 �� SLC Exomder 5860 5824 - ' ti Remote/+ and etor PrrterfGaeway Module ,' 12Ieats Mxt_S190F) _`-- 6 Flexput" �� • i I/O Circuits5815XL can be inputs ' SIr Fartander F or outputs FQ c 6 Flasputii — 4LO ClrnrBs B F can be Inpt N ' - or output d T R \Eel2 op. IIs.9trobea.E a.and NAi-t � PASS.. Cu-emcee. Sue nee Srrae DeteeCTa 4 SK-Ion SK-Nkrn tar SK-Iso SIC-Control-8 SK-Control B200SR SK-Acclimate SK-Zone-6 Addesseele Addesseele Fault Isolator Addressable S pen+sed Sounds Muttentene Zone ,. Frua rel II Monitor Module Nu'ledion otlrot Baa enyJke Intalyaee 5860 Detector Module module Module detector More.Je Rarrro[e/1flnunClelrr --1 0e SK-Photo SK-Monkor-2 SK-Relaymon-2 Sic-Heat B224RB B224131 B27OLP - 6K-Photo-T Cud Monitor Ade...able SK-Heat-ROR Relay Isoaa cetecrer - 5880 AdrCessale Module DU al Monitor ease ease ", LEO Drker& Riotceuctec Wlrwo RAays AddresaLe ase Input Module Detects wxesable Fleet detectors ../ II, Amamifrill f I I I I I 5883 4 Relay Interims Modsle SK-Beam SK-Mon-1O SK-Pull-DA SK-Duct SK-Mnimon SK-Relay-6 5K-Zone SK-Relay 5K-Beam-T Addw;atle SK-Pull-6A Adorasaae Mmlor Pe6y Comm' Addessa4e Adterzalo AGdessacee Monitor Addessoce Duct Module Module Interface Relay Beam Detector Module Purl Staoon Daeclor Module Module 11Ell 5865-4 or 5865-3 I uncer I Use Ole 5880 to control up to 4 , _J (5885D `4' awl) 1 5883 Relay Interface Modules i - IntelliKnight Model 5820XL . Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/lO Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X(two required) reports, and event history. Interfaces with building control system. SILENT This document is not intended to be used for installation purposes.We try to keep our Made in America Its KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSOR SILENT SK-Photo, SK-Photo-T KNIGHT and ° SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor®PN RA100Z) SK-Photo and SK-Photo-T are plug-in • Plug-in mounting provides ease of type smoke sensors that combine a installation photoelectric sensing chamber with addressable analog communications. ' Tamper-proof feature available on Point ID capability allows each mounting bases • Listed for use in duct applications o detector's address to be set with rotary address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable • FM Approved , y levels. e : SK-Photo and SK-Photo-T have a Specifications unique optical sensing chamber that is Physical engineered to sense smoke produced Height:2.0"(5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1" (10.4 cm)installed in sources. In the SK-Photo-T, dual B501 base electronic thermistors add 135°F(57°C) Installation thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base. The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR (W) duct included) (with LED on) smoke detector. Environmental Operating Temperature Compatibility Features SK-Photo: 32°— 120°F ° 0°C—49C (0°C 49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°— 100°F (0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analog communications for Other Ratings B210LP 6" base (included) trouble-free operation SK-Photo-T Thermal: Fixed B501 2 wire base temperature set point 135°F (57°C) 224RB Relay base • Age resistant polymer housing B224BI Isolator base • Dual electronic thermistor design on Velocity:0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 • Dual LED indicators for 360°visibility 5700 5600(Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. e a a v: i>!,,-,",, ,: Compatible FACP RA100Z(Optional) ,711., II -tit% ir 7111‘ . _IP it"..- ,,, i:. t 111#111111‘ ‘iiiriv \a,____,,ly Class A Optional Wiring Wiring SK-Series Detector Mounting Bases SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all le specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E a subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com SILENT SK-Pull-SA and SK-Pull-DA KNIGHT Intelligent Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dualI I E action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight PULL DOWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm conditionti SIIENT' KNIGHT • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms PUSHIN I guidelines (Section 4.1.3[13]) PULLDOWN • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® L,HKtir `. • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS - . - R' Model SK-Pull-DA and SK-Pull-SA • Intelligent Pull Stations • Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. )� ------------------- class A Class B � •,r Compatible FACP n 3 1 2 2 4 ,g, • 1 2 1 3 4 a: Class A Wiring: Class B Wiring: Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5" (14 cm) Average Operating Current(LED flashing): 300 pA Width: 4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST) normally open (N/O) BG-TR Optional trim ring. • switch which closes upon activation of the pull station SB-I/O Surface backbox ' it SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover IQVIGI IT all specific applications or anticipate all requirements.All specifications are • subject to change without notice. For more information,contact Silent FORM#350135 Rev C by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com SILENT SK-Monitor KNIGHT by Honeywell Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control ., panels (FACPs). The SK-Monitor is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. ;� • 4 The SK-Monitor supports Class A supervised or Class B ; � supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. * � Features ,b • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in ,� normal state and is solid red in alarm • Attractive ivory cover plate SK-Monitor • Rotary address switches for fast installation • SEMS screws for easy wiring Specifications • UL Listed Physical Installation Height: 4.5" (11.4 cm) The SK-Monitor mounts directly into a 4" square electrical Width: 4" (10.2 cm) box. The box must have a minimum depth of 2-1/8".A Depth: 1.25" (3 cm) surface mount electrical box (System Sensor®PN Shipping Weight: 6.3 oz (196 g) SMB500) is available from Silent Knight. • Electrical Compatibility Operating Voltage: 15—32 VDC The SK-Monitor is compatible with the following Current Draw (LED on): 5.0 mA max IntelliKnight FACP's: Operating Current (LED flashing): 375 pA 5700 5808 5820XL 5820XL-EVS Model SK-Monitor Intelligent Monitor Module ToNEXT - FROM FARELCR BICE f Ef04ar:ss yr w+ems+ �. �.,� + PREVIOUS DEVICE 0 r MONITOR • ANT AMBER CF LL USTEO CONSII.OT ® MODULE C-1 .! # i CWWBLRE DEVICES MAYBE Ute.DO MDT iii COIiitELT MOOLLE:gTO LISTED DOJPAIIELE FRE ALARM MOWING;SLFEW SIfW.CA 6Q + } 1 + CONTROL FMAREL8 014YB&LFU YOBICE3ONT}ESAYEYDOL E _ 0 ! n / ATIE IDL i SIGNAL IDE CFtCLFT pugFiES113TOR ffi4UCMAX i— YIlEO t3R 4M M•♦ #_ ISTFEODIBT4DEDPIdR BATWING DEVICE CF IIUT QOC,-NFPA STYLE B RENNER UIiTETI:45L01 MAX.0 iI VDC MAX I►i1877AtL(�DFtPCTCLDt Ifs DEVICES PER ALLWFUM3 BHONW S St EFiI18E0 AAEI POWER LASTED YAFttE CTURERBINSTALLATIONNBTF JCfOFW. 2-Wire Initiating Circuit Configuration, NFPA Style B TO NEXT - FROM PANEL OR DEVICE ,. .. '•'-a•s—- ` 0.:.- s..... PREVIOUS DEVICE MONITOR ``I ANY NUMBER OF ITL LISTED CONTACT MODULE I CLOSURE DEVICES MAY BE USED.DO NOT MIX Q r] 0 f CORRECT MODULES TO LISTED COINVITTBLE FIRE ALARM INnATINO,SUPERVISORY,OR 0 to p Co I I NOTIFIER CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. • I �, v 1 _Apo N.' MAN I INE CIRCUM(SLC, s2 VDC MAX. SHIELDED-TWISTED EOL RESISTOR E w••w I PAIRIirEANALAT �.♦ F., ISS TERMINALS 9&S INSTALL CONTACT CLOSURE DEVICES PER AU.WIRING SHOWN 18 SUPERVISED ANY)POWER LASTED MANUFACTUREFFS INUTALIATION INSTRUCTIION& 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 pA max @ 24 VDC (one communication every 5 Operating Temperature: 32°F — 120°F (0°C—49°C) sec with 47K EOL) Humidity: 10% —93% non-condensing 550 pA max @ 24 VDC (one communication every 5 sec with EOL <1K) Ordering Information 5.5 mA(with LED latched on) SK-Monitor Monitoring Module LED Current: 5.5 mA(with LED latched on)End-of-Line • Resistance: 47K S2 Accessories Initiating Device Circuit Wiring Resistance: 1,500 SZ max SMB500 4" Square Surface Mount Electrical . SLC Loop Resistance: 40 0 max. Box SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA iti KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight FORM#350131 Rev D by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, ©2013 Honeywell International Inc. Fax:(203)484-7118.For Technical Support, Please call 8200-446-6444. www.silentknight.com EINIIIIINgl Werke ': Sealed Lead Acid Absorbed Glass Mat Technical Specifications WKAl2-7.5F y Discharge Characteristics Duration of Discharge @ 77°F MN ttuv ta6v ) I 1 t t6zv ._ $ ` '1 "'i' 'fi all id" 1±11-_ I swryti I 6 N -t � � 1 4 as16m so 60 : 6 soma I min 1 hr { K,02.7 a d,,, dh° p Discharge Time ,�;0''' Fad -. G Discharge Duration vs.Discharge Current Duration of Discharge @ Various Temperatures 2oA Itoll �`,,, -----1-,„"1 -f, t 5A 74.:. It ssi +.`p io4F "_l 7 U �* �t rn 77F Specifications 2 to : ,. - 4 i All Specifications Are Rated at 77°F Unless Otherwise Noted 4,... ` '� - 1,1 - worm r.,. :1,...,14. 5 F . Nominal Voltage 12V worm _15 • }. t w_ P�. � t Ampere Hour Capacity(20hr Rate to 1.75VPC) 7.5Ah 1oomA 7t ; [yt ! t 3 ''' inches millimeters 3 5 10 20 40 60 2 4 6 10 15 20.30 Length 5.95" 151±1mm I min { hr I Dimensions Width 2.56" 65±1 mm Discharge Time Height 3.70" 94±1 mm Height w/Term. 3.94" 100±1 mm Weight 5.51bs Capacity Ratings Case Plastic ABS Resin 20 hour rate 7.50AH Maximum Charge Current 0.3C or 2.25A _ Capacity 10 hour rate 7.00AH Float Use Voltage 2.28V/Cell @ 77°F 5 hour rate Recommended Float Use Current <1.1A 6.40AH 1 hour rate 4.65AH Charging Cycle Use Voltage 2.45V/Cell Cycle Use Current <2A 1 Month 97% Wattage Ratings Shelf Life 2 Months 91% End Voltage 3 Months 83% Discharge Rate 1.75V/Cell 1.67V/Cell Charge 32°F to 104°F 5 min.rate 54.1 55.9 Temperature Discharge 5°F to 122°F 10 min.rate 36.5 37.7 Range Storage 5°F to 104°F 15 min.rate 27.8 28.7 Capacity Affected 104°F 103% 30 min.rate 16.9 17.4 by Temperature 77°F 100% 45 min.rate 10.9 10.4 (20hr rate) 32°F 86% 60 min.rate 9.8 10.2 The information contained on this specifrcation is generally descriptive only and is not intended Ascent Battery Supply tic to make or imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive batteries.Cell and battery design/specification are subject to modification without notice. Hartland,WI 53029 rr page 1 of2 Vie rk er. Sealed Lead Acid Absorbed Glass Mat Technical Specifications . WKAl2-7.5F Cycle Life vs.Depth of Discharge Physical Dimensions 120% i i i A B itao% I1at I 0 100% 50%Dptol Vt d c Did_.,.. 4096- Df €'_.,,.._„_.....I_..._..„...Discharge 20% I 0 200 400 600 800 1000 1200 1400 mm Charge/Discharge Cycles A 5.90 151 EillI1 9 256 95 C 3.70 95 0 3.99 101 Effect of Temperature on Float Life 10 Terminal 5 •A in I mm 3 r 11 A 0.185 4.70L. B 0.250 6.35 tnco C 0.031 0.79 } B C j 1 d U Open Circuit Voltage vs.Capacity 0.5 Estimated Residual Capacity @ 77°F 0.3 ' 14.0V 1111111_11111 13.5V al 13.0V O 0.1 > 12.5V _ 50° 68° 86° 104° 122° 140° 158° 12.0V E k° _. .--- ✓ goa ���� Temperature (F°) 11.5V t 11.0V Eno. o IIM- ' '— 10.5V - - • 10.0V 4111i16 igui 0% 20% 40% 60% 80% 100% 11110 Approximate Capacity(%) 111114 WIPS• MH 20720 The information contained on this specification is generally descriptive only and is not intended Ascent Battery Supply LLC to make or imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive Seebatteries. Cell and battery design/specification are subject to modification without notice. Hartland,WI 53029 mr page 2 012 DSC A Tyco International Company HSPA Universal Wireless Commercial Fire Alarm Communicator 1 '� 3G3O7OCF Features That Maket a Difference: • Uses HSPA( G)network for hth sped,reliable analogy; cat commgnlcations t # receiver Automatically switches to 2� (EC GF/QpRS) if 3G service is not available s R 3G technology from DSC! • Compatible with control panels The 3G3070CF connects the alarm path shall be annunciated at the that communicate using the control panel to the HSPA network supervising station and at the Contact ID format and reports alarm signals directly to a protected premises within not more • Full overit reporting monitoring station receiver(Sur-Gard than 24 hours of the failure. System I/ll/III/IV).The 3G3070CF uses • 4:on board Inputs the HSPA network to ensure low- How it Works !.. 4 onboard outputs(open cost, high-speed and reliable alarm The 3G3070CF can be used as collector) communications and is compatible either a Sole Communicator or as a • with control panels that communicate j card (included Backup Communicator.When being using the Contact ID format. •" Activationand initialization via used as a Sole Communicator the automatedtelephone it n The 3G3070CF is compliant 3G3070CF will replace the phone tel neacts or " with the latest requirements for line connection on the panel and systeMmobile interlace web-userprovidby Communications Methods as as soon as it detects that an alarm C24 Communications per UL864 and NFPA72 2010 needs to be transmitted it will send Edition. It can be used in Fire the alarm across the HSPA network • PTM(Panel Transmission Monitoring applications as a single immediately.When being used as a Monitor)switches from PSTN communications technology, backup the communicator assesses to cellular on unsuccessful in which case any failure of the the connection to the PSTN phone communication attempts communications path shall be line, and only in the event of a phone • Compatible with Sur Garde annunciated at the supervising station line failure will it send all alarm traffic System ible 1/IV monitoring within 5 minutes of the failure, or it across the HSPA network to the station receivers' can be used as part of a multiple monitoring station. communications technologies(for In instances where the control panel •• Includes UL listed power example in conjunction with a DACT). does not support Contact ID, the supply, transformer and 7 Ah When used as a back-up provision 3G3070CF has inputs pre-set to rechargeable battery shall be made to monitor the integrity transmit fire alarm,fire supervisory or • UL 864 listed of each communication path and system trouble. failure of any communications • CSFM listed communications Contact your DSC distributor. www.dsc.com 1 1-888-888-7838 . DBD A Tyco International Company Alarm signals are transmitted directly without the need of Specifications �a clearinghouse to the IP linecard of the monitoring station receiver(Sur-Gard®System I/II/IIVIV). Dimensions 11-1/2"x 10"x 3" (29.2 cm x 25.4 cm x 7.62 cm) Activating & initializing the unit Input Voltage 120 VAC Activating and initializing the 3G3070 can be done using Current Draw 300 mA the automated telephone activation system(VRU), mobile Operating Environment 0°to 48°C(32°to 120° F) interface or web-user interface provided by CONNECT 24. No special tools are required. Weight 12.8 lbs(5.8 kg) UL Listing The 3G3070CF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations.When used as a sole communicator the 3G3070CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window.When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT)and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. Ordering Information: 3G3070CF-USA Universal Wireless Commercial Fire Alarm Communicator(U.S. ModeVSIM Card Included) • 0 s 0 0 communications For product information www.dsc.com Product cpeciticatlons and availability subject to change without notice.Certain product names mentioned herein may he trade name,and,'or rod otrred trenenraren of other companies. X2012 2012-06