Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications (13)
RECEIVED APR 1$ 2016 7650 S.W.Beveland St. CITY Y OF TIGARD 1°..11\A TM RIPPEY Tigard,Oregon 97223 BUILDING DIVISION CONSULTING ENGINEERS F (503)443-3700 Faax:x: (503)443-3700 STRUCTURAL CALCULATIONS PROJECT: 14020 SW 72"AVE TIGARD(UNITED RENTALS)RTU'S LOCATION: 14020 SW 72ND AVE TIGARD TIGARD,OR 97224 CLIENT: WILLAMETTE HVAC DATE: APRIL 7,2016 PROJECT NUMBER: 16091 DESCRIPTION: SUPPORT OF 2 REPLACEMENT RTU'S ON AN EXISTING WOOD FRAMED ROOF. TABLE OF CONTENTS: ITEM SHEET NUMBER GENERAL NOTES N1 DETAIL SK1-SK5 CALCULATIONS Cl-05 CITY OF TIGARD REVIEWED FOR C9 E COMPLIANCE E% FRU44 Approved: [ ¢o w x,5 1' OTC: [ CM 10 r', Permit#: — !( �-tea OREGON . Address• _� 1► 41. ,1111 (9 se,r 19,,�Oob��w, Suit : y�4 kYLEtV By: Date: f .424K) IFYP: Ai/to • OFFICE COPY GENERAL STRUCTURAL NOTES CODE REQUIREMENTS: CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS AMENDED BY THE 2014 OREGON STRUCTURAL SPECIALTY CODE, REFERENCED HEREAFTER AS IBC. DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE IBC. IN ADDITION TO THE DEAD LOADS,THE FOLLOWING LOADS WERE USED FOR DESIGN: NEW 3-TON UNIT WEIGHT(NOT INCLUDING EXISTING CURB):490 LBS NEW 2-TON UNIT WEIGHT WITH REQUIRED CURB ADAPTOR(NOT INCLUDING EXISTING CURB):406 LBS ROOF DEAD LOAD:15 PSE ROOF SNOW LOAD:25 PSF BASIC WIND SPEED(3-SEC GUST,ULTIMATE):120 MPH WIND EXPOSURE:B SITE CLASS:D SDS=0.720 SEISMIC DESIGN CATEGORY:D EXISTING CONDITIONS: THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS,DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES FROM CONDITIONS SHOWN ON TILE DRAWINGS PRIOR TO THE START OF THE WORK. TEMPORARY CONDITIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY OF THE NEW AND EXISTING STRUCTURES AND WALLS DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER TIIE FINAL CONFIGURATION ONLY. CARPENTRY: SA\VN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION,LATEST EDITION. SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. UNLESS NOTED OTHERWISE ALL LUMBER SHALL BE 19%AT TIME OF FABRICATION AND DRIED TO A MAXIMUM OF 15%BEFORE INSTALLATION OF GYP.BOARD AND VERIFIED BY THE GENERAL CONTRACTOR. ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR CMI I SHALL BE PRESSURE TREATED UNLESS AN APPROVED BARRIER IS PROVIDED.FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY(OR ENGINEER APPROVED EQUAL)AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND ATTACHED PER MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS UNLESS NOTED OTHERWISE. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL FRAMING NAILS SHALL BE COMMON NAILS. NO BOX NAILS ALLOWED. FASTENERS AND ACCESSORIES IN CONTACT WITH PRESERVATIVE TREATED WOOD MUST BE HOT DIPPED GALVANIZED OR HAVE ZMAX COATING. MECHANICAL: THE CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF ELECTRICAL EQUIPMENT,MECHANICAL,PLUMBING,FIRE SPRINKLER, MACHINERY,AND ASSOCIATED PIPING WITH THE STRUCTURE. ANY CONNECTIONS TO STRUCTURE NOT CONFORMING TO SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION(SMACNA),OR SPECTFTCAT.LY DETAILED ON THE MECHANICAL ENGINEER'S DRAWINGS,SHALL BE DESIGNED IN ACCORDANCE OF THESE GENERAL NOTES,BY AN ENGINEER REGISTERED IN THE STATE OF OREGON,AND SHALL BE SUBMITTED TO THF.ARCHTTECT/ENGTNEER PRIOR TO FABRICATION. FLASHING AND WATERPROOFING: _a ALL FLASHING AND WATERPROOFING SHALL BE BY OTHERS UNLESS NOTED OTHERWISE ON THE PLANS. -'-- I♦} ' Yr,. dj{ .a. ... .?Y((b.b,.r, %T.'4a.•a4xnn-i•:Yv»s✓'z+zaS ..4t*w'n.,.w+.ryM� I 7f K TM RIPPEY LYl Consulting Engineers By: JH Date: 4/6/16 7650 SW Beveland Street 14020 SW 72N"AVE TIGARD RTU'S , - CI&By: , Date: Suite 100 Tigard,Oregon 97223 Job#: 16091 Phone:(503)443-3900 Sheet: NI OF • t"a?;.,i UIk,T%; „ . . t9vaaw ,a,=. ?�:a§t#w 'i k.; ;b��'r`ass AB9&'` r. AREA OF WORK FOR 3-TON RTU ' REPLACEMENT F,, NO CURB ADAPTOR � ""' SEE 1/SK2 s AREA OF WORK FOR 2-T ON RTU REPLACEM ENT� . � �F'� WITH CURB ADAPTOR PTOR ,.- FSJ"ty 5 SEE 1/SK3 amw r I �'.w. , 2'<. _»,�, n>_ ..--,............,, . . „,..'... .• ..,,.,:'..,,,,,,j.,:''..1:','' ''''''-" ' **,46.:•.,-Ito,K0_,,,,, ....„':::::::::14:::iti.::.''''''''....,.....,!:::::.....,:!i•.,:.::.!,:".111.11.1,?,!!i':-.'.'...,•,,it!'.1.1„,i;•;:,,..:':::.....-.:'....,...... ' .!,!: ' : •-. .'• '. .o- n , ... .r ,. Flak :. ! �` F A j 5... "' ' t sF ; . t ,v 3.:.a,:. e�za, _ l3 f t'�g2,CF ♦F�lay �` � :'� {ev♦ -u � � �� ♦ u ., sd F ♦ � a"R?t_ tk y4Lr irprt .1:��� ��,`s2 ' 4 ..::::::::,.'.1...:',.,,..',,:5,-..,.,:., r ,if �2::tis . .,,: E't?moi Y )4t�Fp ?\b;r; y,2��?:i� 7Yz.. .,&o�� ° '�'�7� �, ADDRESS: 14020 SW 72ND AVE. TIGARD,OR.97224 1 SITE PLAN SKl TM .RIPPEY BY CHK BY DATE 1M?4 .. JH DATE 4/7/16 CONSu[TINGENGINEEas 14020 SW 72ND AVE TIGARD RTU'S 7650 S.W.Beveland St,Suite 100 joB No 16091 • Tigard,Oregon 97223 Phone(503) 443-3900 sHEET OF NEW 4x6 DF#2 HEADER UNDER NEW RTU(BY SUPLLIER) UNIT CURB,NEXT TO DUCT WEIGHT(INCLUDING CURB)=605 LBS. DROPS. SEE DETAIL 1/SK4 FOR EDGE OF UNIT ON EXISTING GLULAM BEAM. CONNECTIONS AT ENDS. FOR EXACT LOCATION SEE MECHANICAL PLANS. EXISTING WOOD I-JOISTS @ 2'-0" 0/C. NNNN 7"....,, EXISTING GLULAM BEAM EXISTING /Y t Ly e I PLYWOOD ROOF ?.: 4 SHEATHING I x SPANNING BETWEEN JOISTS. TYP. 1 K S x K74 NEW 4x6 OF#2 HEADER v ATTACH INSIDE FACE OF(E) UNDER SHORT EDGE OF ATTACH INSIDE FACE METAL CURB TO TOP OF UNIT CURB,TYP. SEE OF METAL CURB TO HEADER WITH SIMPSON DETAIL 1/SK4 FOR INSIDE FACE OF HGAIO CLIP W/(4)1/4 x 3" CONNECTIONS AT ENDS. HEADER WITH PLATE SIMPSON SDS SCREWS TO AS PER 1/SK4 HEADER AND(4) 1/4" SCREWS TO METAL CURB. CENTER CLIP ON WIDTH OF HEADER. NOTES: -INSTALL ALL FRAMING PRIOR TO INSTALLING CURB. -ALL WATERPROOFING IS BY OTHERS. -SEE MECHANICAL PLANS FOR ALL OTHER INFORMATION. cs-i-- FRAMING PLAN AT 3-TON RTU K2) IMI . TM RIPPEY BY JH DATE 4/6/14 CONSULTENGENGINEERS 14020 SW 72ND AVE.TIGARD RTU'S CHK BY DATE 7650 S.W.Beveland St,Suite 100 JOB No 16091 "__ Tigard,Oregon 97223 Phone(503)443-3900 SHEET SK2 OF • NEW RTU(BY SUPLLIER) ATTACH INSIDE FACE OF(E) WEIGHT(INCLUDING CURB)=521 LBS. METAL CURB TO FACE OF EDGE OF UNIT ON EXISTING GLULAM BEAM. JOIST WITH(4)SIMPSON FOR EXACT LOCATION SEE MECHANICAL LTS12 TWIST STRAPS W/(6) PLANS. 10dx1-1/2" NAILS TO JOIST AND(6)#10 SCREWS TO METAL CURB. EXISTING WOOD EXISTING 2x10 JOISTS @ 1'4" GLULAM BEAM 0/C(VERIFY). EXISTING PLYWOOD ROOF SHEATHING ' h SPANNING �� TYP. BETWEEN JOISTS. Anhi atigagatignZ $x s Y y YCHii j h., f N k NOTES: -INSTALL ALL FRAMING PRIOR TO INSTALLING CURB. -ALL WATERPROOFING IS BY OTHERS. -SEE MECHANICAL PLANS FOR ALL OTHER INFORMATION. 4111) FRAMING PLAN AT 2-TON RTU MTM RIPPEYBr JH DATE4/6/14 CONSUITINGENGINEERS 14020 SW 72ND AVE.TIGARD RTU'S CHK BY DATE 7650 S.W.Beveland St,Suite 100 )OB NO 16091 • _ Tigard, Oregon 97223 sHEET�$ 3_OF Phone(503)443-3900 • MECHANICAL UNIT EQ. SPACED BOTH WAYS sz41144 BY OTHERS TYP. 41- 10 GA. CLIPS W/ (8) *10 TEK SCREWS PER Io GA. CLIP CLIP, (4) CLIPS REQ'D. N.T.9. SEE PLAN VIEW FOR via CLIP LOCATION I• I'-(d", TYP. CLIP WOOD BLOCKING � LOCATION REQUIRED (4) TOTAL FLASHING AND INSULATION MEGH. UNIT NOT SHOWN FOR CLARITY OUTLINE PLAN VIEW WATERPROOFING BY OTHERS N.T.6. S/77)r /Ji f..... 7, t # PROVIDE 16GA PLATE x 8"x SIMPSON'LUS44' ' REQD W/(3)#10 SCREWS TO HANGER EACH END. (E)UNIT CURB AND(3)#10 SCREWS x 3-1/2"PENETRATION OF:4x6HEADER TOC WOOD. CUT FOR SHEATHING AS . .- NEN 4 . INSTALLATION. PROVIDE 2x8 D.F.#2 EACH --- SIDE OF WEB AT EACH END OF 4x6 HEADER W/(6) .:.: TOTAL 16d NAILS, (3) - NAILS TO EACH 2x8. ,... .,.4. 1/4"GAP INSTALL TIGHT TO TOP CHORD .. '. .. . (E)ROOF JOIST , . ..: 1 SECTION'AT CURB SK4 SCALE. 1-1/2„ = 114" 1MTM RTPPEY BY 11 DATE � CONSULTING ENGINEERS 14020 SW 72ND AVE TIGARD RTU'S CHK BY DATE 7650 S.W.Beveland St,Suite 100 JOB No 16091 Tigard,Oregon 97223 SHEET SK4 of Phone(503)443-3900 • TYP. 11111 CLIP LOCATION, TYP. EQ. SPAGED ' NEW RTU BOTH WAYS TY . � I�-� PLAN NEW RTU --- Si' i2 N.Tb. 16 GA. CLIP NT.S. 16. GA. CLIP W/ (8) 6I0 x gra" GALVANIZED TEK SCREWS, (4) CLIPS REQ'D. SEE DETAIL 'A' (PLAN VIEW) II FOR CLIP LOCATION A NEW CURB ADAPTOR (DESIGN BY "10 X 1"2" GALVANIZED OTHERS) TEK SCREWS 1' -0" 0/C 4 6" FROM ENDS. (4) MN. PER SIDE, TYP. ,1- FLASHING AND INSULATION TI N EXIST. CURB NOT SNOW FOR CLARITY TO REMAIN 11, (E)RTU CURB TO BE CONNECTED TO JOISTS WITH TWIST STRAPS SEE 1/SK3 FOR -- LOCATION AND INFO ."r NEW OR EXISTING STRUCTURAL MEMBER SECTION AT CURB SKS SCALE: 1-1/2" = 1'-0" TM RIPPEY CONSULTING ENGINEERS 14020 SW 72ND AVE. TIGARD RTU'S CHKBYBY in DATE DATE 7650 SW Beveland,Suite 100 JOB NO 16091 Tigard,Oregon 97223 Phone:(503)443-3900 SHEET SKS OF Fax:(503)443-3700 — 3 1 oT• l�SS�mi. q TJt/3SP �rc�M Tri^S 3oi-SL. MG.c.re\Ll..t_a,n Lo kv14 (l,`i4) (GAsre Orj pal.D n sun. ) M 1v Go5-0 16. '}G �O G.0 I•r"-'!: \/ 1 zpl `tt 12.10 16 ` PV DL-. ICpsF l- ` /19. 25 t GOS t 5/2 (0'`aS-M.I\f1 Y7... L.ieLet+ le CJIt`, ( I 1 i 1,-,1`)- 1710 10 f,,.,:.- a Ti�j.p. lb 4 569 t r r ., :V". 1• 1. 4 i. ,L I. L. C33 tAts,:32 3(13 8I) / S` ,, f k-s (J1 x. ,(1.,,2-,) C o� C e' P.1-1) i�,I;. 8,8 lb ���n��t�, f 3s Ib v(1b) 11111h - AcAeic. $sslb cLeAc reStas / / Le 5S Lk S"/ 1oS� $st L ° �.�t J-i E;s c�nc�l. r� sC,rw-L,r‘ i r •t!-,e Jot 9.3"3 Dere cocc ti ttil tc c..Cxc r�5 �._,C U { (SFS G. SSC f.�..L �„A f�•`,!'� -1 5-6�• Co v S 5 L 20 I 14 Se_C00". 314 U`+ E4) TM RIPPEY BY J I-4 DATE L,/7J J r" CONSULTING ENGINEERS CHK BY DATEe 6 0 ti O 2-0_ a 72.no( Ave_ � T� 1:1 . 7650 S.W.Beveland St,Suite 100 JOB NO 16o O9 Tigard,Oregon 97223 Phone(503) 443-3900 SHEET L IA OF 7_ x Ica P.SShr�Lc-N., OF L 142 • (9a0)(1 Is)( 1.I )( 1. ► 0 iv(0)) 2 E, s L L L L L L L l�,ye 'la 4 ray L : 2_0 �-: a-5"3,31:2ca�t JCI) `^fw 521 bs/� ��,� �. ,` 11 5-411 (io) c 6= 2.3 7 (t2) V(►b) = 6 Qs i /zi.31Ln� 36 Gci t1J I sS6 P ? • NO 0 c L0od s AtvA.(Jsi, 991-1111,14 • t'ICI PA. V Vit!t • T� \ '110• rIC,e4ittlIA$ C.414 Z]G 1TM RIPPEY BY 31 DATE / C ONSULTING ENGINEERS //�� AveLI V 2-V 4�1.-.✓ �2.n el( !-y . � �..C��._(�c� f`i��-)'(' CHK BY DATE I,I 7650 S.W.Beveland St,Suite 100 JOB NO 16 09 ) Tigard,Oregon 97223 Phone(503)443-3900 SHEET 'g OF aro, Rio Wind and Seismic Loads on Mechanical Unit Worksheet Calculates the wind and seismic forces for a rooftop mounted mechanical unit based on the ASCE 7-10. H old down forces are calculated based on 0.6D + (0.6W or 0.7E) load cases. Wind and Seismic Loads on Mechanical Unit Windspeed:= 120mph 7xposure:= "B" Vasd "no11 (Is wind speed ASD?) Seismic Parameters SDS:_ .720 := 2.5 ap := 6.0 RP IE:= 1.0 Building Dimensions Category:= "II" Roof Elevation:= 2011 Building_Width:= 9011 Building_Depth:= 40ft Mechanical Unit Dimensions Displacement "Fan Unit" Weight:= 6051b UnitHeight:= 33.375in Width:= 44in Length:= 74.375in Curb:= 14in Curb_Width:= 40in (Dimension for Calculating Overturning Uplift) SUMMARY(ALL VALUES ARE ASD) Method Used= "ASCE 7-10-Section 29.5.1" D = 605 lb _ - WWindUpliftASD= 435 lb Displacement= "Fan Unit" I (From ACSE 29.5-3) 0E._ EASD= 152 lb hseismic=2.557 ft $ — WWindASD = 593 lb (From ACSE 29.5-2) hWind= ,1.974ft 1 X= 3.333ft� TWindTotalASD= 387 lb Notes: TseismicASD= -651b 1.Positive sign convention shown.Negative values indcate opposite direction 2.X equals the width between attachment points for overturning irVIR.(I11 NVA to -' l' �) 690IbS upA- (i) ft 10 Si.Keli it 1 V/.k -1 ---"/ ) '1, 1- IIJ1 .1,.,_._'-1"(41.'O.) 63 z ► Rft) Wind and Seismic Loads on Mechanical Unit Worksheet Calculates the wind and seismic forces for a rooftop mounted mechanical unit based on the ASCE 7-10. Hold down forces are calculated based on 0.6D + (0.6W or 0.7E) load cases. Wind and Seismic Loads on Mechanical Unit Windspeed:= 120mph 3xposure:= "B" V „ asd'= „no (Is wind speed ASD?) Seismic Parameters SDS:= .720 ap:= 2.5 Rp:= 6.0 IE:= 1.0 Building Dimensions Category:= "II" Roof Elevation:= 20ft Building_Width:= 45ft Building_Depth:= 4511 Mechanical Unit Dimensions Displacement:= "Fan Unit" Weight:= 5211b Unitlleight:= 42.125in Width:= 31.4375in Length:= 44in Curb:= 30in Curb Width:= 36in (Dimension for Calculating Overturning Uplift) Method Used= "ASCE 7-10-Section 29.5.1" SUMMARY(ALL VALUES ARE ASD) Method_ Used = 5211b - WWindUpliftASD= 186 lb Displacement= "Fan Unit" (From ACSE 29.5-3) EASD= 1311b hseismic=4.25511 $ WWindASD= 541 lb (From ACSE 29.5-2) X= 3ft hWd= 3.005 ft TWindTotalASD=479 lb Notes: TseismicASD= 30 lb 1.Positive sign convention shown.Negative values indicate opposite direction 2.X equals the width between attachment points for overturning (2.) LLT. (7. -3 It 60 I'.," cej't!' EE llnYY/lI Pec cot &Cc c.&ec Ur Cenr\e r I:ed, (ca 1 c3° % " ( L,rc. ' fvt 51�trr1R (-{ • 4/7/2016 Design Maps Summary Report MUMS Design Maps Summary Report User-Specified Input Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 45.41873°N, 122.74926°W Site Soil Classification Site Class D - "Stiff Soil" Yr"rtI .a.:ts.. .' .......,5„.,.,,,,,..,,,19 , , F,...suRisk Category I/II/II ' .n .x a-.>' /1 z Yza � '. ` ' 3i ar1f- r � 'x s� S E ' frr' iHyA R-� x . , Z.i igigii � � si' gieffrn ifg.r aVi • • ',` x <r $ t 1 : y ' obyl, s . yasm ' a 4A, Ass I,r ` 44Wf . r " # � y 7-� tIg diFa e �R i , S�M. � � :ir. x�e4Q . .4, sg S s• s£f{ y T yam � " Y at a S . ...-:,:,-,,,iii, va f 4 "y s , 3 �,,.4a1T - 7 � 4 •- r` x '-,� : -� ' r �. ' ;p• ma .,J � ,: a ? & _yY@ • ,D�S �Y' 3LK ., y. s .», k34 .... 4 ,VY A- +, E:i .::£ v , 22,„ ,:,...,t,..,? y y , .. o k ri?o �� i�Cy �ph:Yk } `'a 5 e � ss, a & : N'3 xyy . Y,� , sZs; i0i.a �`Y1 ui z N� � ° ,. ;� , 3 r44. & n f‘.;_:;„0., S. f1 S aezoi �-'',64)0444-',ii-,374'02,10-1:',:' s T � _ c 3 L d1 �.. ' � 6 � .43 .a vq wa ; f. ,'�: 's n wc # t' %' � 6 x :; a h xS ` . s sa-, st"c3 ! rt li • .' r \3 # a u . ....a.w, s ,N� " _»`i °% amR .Y. T ° £.,..�,a.&o -- USGS-Provided Output SS = 0.973 g SMS = 1.081 g Sos = 0,720 g S1 = 0.421 g SMi = 0,665 g SDi = 0,443 gg For information on how the SS and Si values above have been calculated from probabilistic (risk targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP"building code reference document. MCER Response Spectrum Design Response Spectrum 0.22 0.80 1.10 0.95 0.72 0.22 0.64 0.77 0.56 11 0.66 OI 0.49 0.55 0.40 f 0.44 0.32 0.33 0.24 0.22 0.15 0.11 0.02 0.00 0.00 0.00 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.20 2.00 0.00 0.20 0.40 0,60 0.00 1.00 1.20 1.40 1,50 1.20 2.00 Period, T(sec) Period, T(sec) For PGA,, T„ C,„, and CR, values, please view the detailed report. Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, l� as to the accuracy of the data contained therein. This tool is not a substitute: for technical subject matter http://ehpl earthqualm.cr.usgs.goWdeslgnmaps/us/summaryphp?template=minimal&latitude=45.41872647260237&longRude=-122.74925977248488&siteclass=3.. 1/2 (:,1S HEAT/ELECTRIC COOTOP 14 SEE LING b SINGLE PACKAGED ROOFR • 3 TO 5 NOMINAL TONS Heating&Cooling Systems Product Data I ,EGL LIN E f ', " w 31 brE EE . „,:t.,,,.,,,,,,,,, 531'$1 �' ` �� FCS C '" 3 y 33 ; 3 �� N ':ok�`4�, -t14",",',;."-. i off"/ � � t E FNM, o ink n � wa A3 b3 3 fi C08515 (Shown with optional Louvered Hail Guard) (4_F_) SHAT Peron COMPS IANT FEATURES AND BENEFITS • Single cooling stage models • SEER up to 14.1. •EER's up to 12.0. • Up to 28%lighter than similar industry units. Lighter rooftops make easier replacement jobs. • Utility connections are the same because 3 - 5 ton units fit on existing Bryant rooftop curbs.This saves time and money on replacement jobs. • Standardized components and layout. Standardized components and controls make service and stocking parts easier. • Scroll compressors on all units.This makes service,stocking parts,replacement,and troubleshooting easier. •Field convertible airflow.Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. • Standard Direct Drive - ECM indoor motor with optional belt drive system to meet nearly all applications. •Provisions for bottom or side condensate drain. • Capable of thru-the-base or thru-the-curb gas line routing. N CO • Single-point gas/electrical connection. • Sloped,composite drain pan sheds water;and won't rust. • Standardized controls&control box layout. Standardized components&controls make stocking parts&service easier. •Tool-less filter access door. • Clean,large,easy to use control box. • Color-coded wiring. • Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. • Single,central terminal board for test and wiring connections. •Fast-access,handled,panels for easy access on normally accessed service panels. • "No-strip"screw system guides screws into the panel &captures them tightly without stripping the screw,the panel,or the unit. • Mechanical cooling(115°F to 40°F or 46°C to 4°C)standard on all models.Winter Start Kit allows cooling operation down to 25°F(-4°C)and MotorMaster to-20°F(-29°C). • High efficiency,gas heat with induced-draft flue exhaust design. • Induced draft motor ensures no flue gas can escape into the indoor air stream. • Bryant designed naturally draining heat exchanger,unlike positive pressure heat exchangers,do not need to be periodically,manually drained. This saves labor and maintenance expense. • 2-in(51mm)disposable filters on all units. • Refrigerant filter-drier on each circuit. • Each circuit is protected with a high and low pressure switch. • Many factory-installed options ranging from air management economizers,2 position dampers,plus convenience outlets,disconnect switches and smoke detectors. • Standard(parts only)Warranty: 15 yr. Stainless steel, 10 yr.aluminized heat exchanger,5 yr.compressor, 1 yr. parts. • Factory-installed Perfect Humidity'" dehumidification system on all sizes,includes MotorMaster I controller. 3 MODEL NUMBER NOMENCLATURE Position: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Example: 5 8 2 J E 0 6 A 0 7 2 A 0 B 0 A A Unit Type Packaging and Control 582-Gas Heat RTU,Legacy Series A= Standard Packaging,electro mechanical controls that require W7212 EconoMi$er IV Model B= LTL Packaging,electro mechanical J - Puron®(R 410A)Refrigerant controls that require W7212 EconoMi$er IV C= Standard Packaging,electro mechanical controls that require W7220 EconoMi$er X Voltage F = LTL Packaging,electro mechanical E= 460-3-60 controls that require W7220 EconoMi$er X J = 208/230-1-60 P= 208/230-3-60 Factory Installed Options T = 575-3-60 OA =None NOTE:See the 582J 3 to 5 ton Price Pages Cooling Tons for a complete list of factory installed c‘i 04- 3 tons options. 05-4 tons 06- 5 tons Outdoor Air Options A= None Refrig.System/Gas Heat Options B= Temperature Economizer,Barometric Relief, A= Standard One Stage cooling models/Nat.Gas Heat Standard Leak(W7212 or W7220) B= Standard One Stage cooling models/Low NOx Heat E= Temperature Economizer,Barometric Relief, C= Standard One Stage cooling models/SS HX Heat Standard Leak w/CO2(W7212 or W7220) G= One-Stage cooling models/Alum Heat Exchanger H= Enthalpy Economizer,Barometric Relief, with Perfect Humidity M Standard Leak(W7212 or W7220) H= One-Stage cooling models/Low NOx Heat L = Enthalpy Economizer,Barometric Relief, with Perfect Humidity Standard Leak w/CO2(W7212 or W7220) J = One-Stage cooling models/Stainless Steel Exchanger Q= Motorized 2 Position Damper with Perfect Humidity U= Temperature Economizer,Barometric Relief, Ultra Low Leak(W7220) Heat Level Input W= Enthalpy Economizer,Barometric Relief,Ultra Low Leak Standard/Stainless Steel (W7220) 072=72,000 115=115,000 Indoor Fan Options 150=150,000 0 = Direct Drive ECM Low NOx 2 = Medium Static Option 060=60,000 3 = High Static Option 090=90,000 120=120,000 Coil Options(RTPF)(Outdoor-Indoor-Hail Guard) A= Al/Cu-Al/Cu B= Precoat Al/Cu-Al/Cu Note:On single phase(-J)voltage code)models,the C= E-coat Al/Cu-Al/Cu following are not available as a factory installed option: D= E-coat Al/Cu-E-coat Al/Cu -Perfect Humidity E= Cu/Cu-Al/Cu -Coated Coils or Cu Fin Coils F = Cu/Cu-Cu/Cu -Louvered Hail Guards M= Al/Cu-Al/Cu—Louvered Hail Guard -Economizer or 2 Position Damper N= Precoat Al/Cu-Al/Cu—Louvered Hail Guard -Powered 115 Volt Convenience Outlet P= E-coat Al/Cu-Al/Cu—Louvered Hail Guard Q= E-coat Al/Cu-E-coat Al/Cu—Louvered Hail Guard R= Cu/Cu-Al/Cu—Louvered Hail Guard S= Cu/Cu-Cu/Cu—Louvered Hail Guard C14337 4 Table 2-AHRI COOLING RATING TABLE NET NOM. TOTAL UNIT COOLING CAPACITY COOLING POWER SEER EER STAGES (TONS) CAPACITY (MBH) - 582J*04 1 3 35.4 3.0 14.0 12.00 582J*05 1 4 47.5 4.0 14.0 12.00 582J*06 1 5 58.5 4.9 14.1 12.00 LEGEND NOTES: AHRI - Air Conditioning,Heating and Refrigeration 1. Rated in accordance with AHRI Standard 210/240. Institute Test Standard 2. Ratings are based on: ASHRAE - American Society of Heating,Refrigerating Cooling Standard: 80°F (27°C) db, 67°F(19°C) wb indoor and Air Conditioning,Inc. air temp and 95°F(35°C)db outdoor air temp. EER - Energy Efficiency Ratio 3. All 582J units comply with ASHRAE 90.1 Energy Standard for SEER - Seasonal Energy Efficiency Ratio minimum SEER and EER requirements. 4. 582J units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes. N kill �� ti.�i CERTIFIED co co Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the 11$111, �. program For verification of certification for individual �� . products,go to www.ahridirectory.org. COMPLIANT Table 3-HEATING RATING TABLE- NATURAL GAS&PROPANE AL/SS HEAT EXCHANGER THERMAL UNITS GAS HEAT TEMP RISE EFFICIENCY A(%)E INPUT/OUTPUT INPUT/OUTPUT (DEG F) (%) STAGE 1 (MBH) STAGE 2(MBH) LOW - 65/50 25-55 82.0% 81.0% 04 MED - 90/73 45-85 82.0% 81.5% HIGH - - - - - d a LOW - 65/50 20-55 82.0% 81.0% t d 05 MED - 90/73 30-65 82.0% 81.2% c HIGH - 130/105 45-80 82.0% 81.0% In LOW - 65/50 10-55 82.0% 81.0% 06 MED - 90/73 25-65 82.0% 81.2% HIGH - 130/105 35-80 82.0% 81.0% LOW - 72/56 25-55 82.0% N/A 04 MED 82/66 115/89 55-85 80.0% N/A HIGH - - - - - d ie LOW - 72/56 25-55 82.0% N/A t a 05 MED - 115/90 35-65 81.0% N/A N i HIGH 120/96 150/117 50-80 80.0% N/A LOW - 72/56 20-55 82.0% N/A 06 MED - 115/90 30-65 81.0% N/A HIGH 120/96 150/117 40-80 80.0% N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m).For information on propane or altitudes above 2000 ft (610 m),see the Application Data section of this book.Accessory Propane/High Attitude kits are also available. In the USA the input rating for altitudes above 2000 ft(610m)must be derated by 4%for each 1000 ft(305 m)above sea level.In Canada, the input rating must be derated by 10%for altitudes of 2000 ft(610 m)to 4500 ft(1372 m)above sea level. 8 Table 6—MINIMUM-MAXIMUM AIRFLOW RATINGS- NATURAL GAS&PROPANE VOLTAGE UNIT HEAT COOLING AL HX HEATING SS HX HEATING LEVEL MINIMUM MAXIMUM MINIMUM MAXIMUM MINIMUM MAXIMUM LOW 900 1970 900 1970 582J*04 MED 900 1500 800 1520 800 1520 HIGH — — — — LOW 900 2470 900 2470 SINGLE 582J*05 MED 1200 2000 1050 2280 1050 2280 PHASE HIGH 1230 2190 1230 2190 LOW 900 3290 900 3290 582J*06 MED 1500 2500 1050 2730 1050 2730 HIGH 1230 2820 1230 2820 LOW 990 2190 990 2190 582J*04 MED 900 1500 1000 1550 1000 1550 HIGH — — — — LOW 990 2190 990 2190 CV THREE Lc) PHASE 582J*05 MED 1200 2000 1330 2460 1330 2460 � HIGH 1390 2220 1390 2220 LOW 990 2730 990 2730 582J*06 MED 1500 2500 1330 2880 1330 2880 HIGH 1390 2780 1390 2780 10 Table 7-PHYSICAL DATA (COOLING) 3 - 5 TONS 582J*04 582J*05 582J*06 Refrigeration System #Circuits/#Comp./Type 1/1/Scroll 1/1/Scroll 1/1/Scroll Puron©refrig.(R-410A)1 phase (lbs-oz) 7.1 10.5 16.0 Puron®refrig.(R-410A)3 phase (lbs-oz) 7.1 10.5 14.5 Perfect Humidity Puron®refrig.charge(lbs-oz) 10.4 15.3 26.0 Metering Device(A) Acutrol Acutrol Acutrol Perfect Humidity Metering Device(B) Acutrol+TXV Acutrol+TXV Acutrol+TXV High-press.Trip/Reset(psig) 630/505 630/505 630/505 Low-press.Trip/Reset(psig) 54/117 54/117 54/117 Compressor Capacity Staging(%) 100% 100% 100% Evap.Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 3/15 3/15 4/15 Total Face Area(ft2) 5.5 5.5 7.3 Condensate Drain Conn.Size 3/4-in 3/4-in 3/4-in Perfect Humidity Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 3.9 3.9 5.2 Evap.Fan and Motor Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct c0 Max BHP 1 1 1 in Standard RPM Range 600-1200 600-1200 600-1200 Static Motor Frame Size 48 48 48 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.2 1.2 1.2 Medium RPM Range 560-854 560-854 770-1175 Static Motor Frame Size 48 48 48 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.5 1.5 1.5 High HighRPM Range 770-1175 770-1175 1035-1466 Static 1 phase Motor Frame Size 56 56 56 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct Max BHP 1 1 1 Standard RPM Range 600-1200 600-1200 600-1200 Static Motor Frame Size 48 48 48 3 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 11 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Medium Max BHP 1.7 1.7 2.9 diRPM Range 770-1175 920-1303 1035-1466 St3 phase Motor Frame Size 48 56 56 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 2.9 2.9 2.9 High RPM Range 1035-1466 1208-1639 1303-1687 Static Motor Frame Size 56 56 56 3 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Cond.Coil 1 phase Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 16.5 16.5 21.3 3 phase Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows..Fins/in. 1/17 2/17 2/17 Total Face Area(ft2) 16.5 14.6 18.8 Cond.fan/motor Qty/Motor Drive Type 1/Direct 1/Direct 1/Direct Motor HP/RPM 1/8/825 1/4/1100 1/4/1100 Fan diameter(in) 22 22 22 Filters RA Filter#/Size On) 2/16x25x2 2/16 x 25 x 2 4/16 a 25 x 2 OA inlet screen#/Size(in) 1/20x24x 1 1/20x24x 1 1/20 x 24 x 1 11 Table 9—PHYSICAL DATA (HEATING-THREE PHASE UNITS) 3 - 5 TONS 582JE/P/T04 582JE/P/T05 582JE/P/T06 Electrical Three Phase Three Phase Three Phase Gas Connection #of Gas Valves 1 1 1 Nat.gas supply line press(in.w.g.)/(PSIG) 4—13/0.18—0.47 4—13/0.18—0.47 4—13/0.18—0.47 LP supply line press(in.w.g.)/(PSIG) 11 —13/0.40—0.47 11 —13/0.40—0.47 11 —13/0.40—0.47 Heat Anticipator setting(Amps) 1st stage 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 Natural Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 N Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT 00 MED Rollout switch opens/closes 195/115 195/115 195/115In Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Liquid Propane Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Low NOx Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 20—50 20—50 15—50 #of stages/#of burners(total) 1/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 30—60 30—60 25—60 #of stages/#of burners(total) — 1/3 1/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 40—70 35—70 — Not applicable 13 582J • NOTES: UN[fED P.O.BOI.101 DOS DOCUMENT IS THE PROPERTY OR CARRIER CORPORATION SUBMISSION Of THESE DRAWINGS OR DOCUMENTS C TECHNOLOGIES s+AAcu6[.N+ A D IS DELIVERED UPON THE EMPRESS CONDITION THAT THE DOES ROY CONSTITUTE PART I[A[dIMANF M 1 DIMENSIONS ARE IN INCHES. DIMENSIONS UNIT J K It PHASE) K 13 PHASE) CARRIER uDR1 CORgNTS+uL NDT RE DIECLASER ON 55(5 WITHOUT CARNI[R ACCEPTANCE OF CONTRACT. ?ERFO IN I 1 ARE IN MILLIMETERS. 5821 01 77 3/8 11 7/8 11431718 CORPORATION S+AI ITER Cas[n. 2.B CENTER OF GRAVITY 18171 11771 73 3/8 11 7/8 18 5/8 CONNECTION SIZES 582'OS [8171 [3771 11721 A 1 3/8' 1351 DIA FIELD POWER SUPPLY HOLE 3.millin,DIRECTION OF AIR FLOW '11 318 11 118 18 5/8 582J 06 110511 13171 11721 D 2' 1501 DIA POWER SUPPLY KNOCKOUT C 1 3//' 1511 DIA GAUGE ACCESS PLUG D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE 33-3/8 [8481 E 3/1'-I1 NPT CONDENSATE DRAIN F 1/2'-11 NPT GAS CONNECTION • I G 2 1/2' 1611 DIA POWER SUPPLY KNOCK-OUT 32-1/4 - A ECONOMIZER HOOD [8181 (OPTIONAL) I6 14161 �/�7 FILTER ACCESS PANEL I THESE HOLES REOU IAED FOR USE (TOOL-LESS) COMP. CONDENSER CRD HMPWROOEA01, 003A01 CCESS COIL ---_ .. .. _ . PA EL .1" THREADED WIRE REO'D HOLE INDOOR COIL I • • CONDUIT SIZE USE SIZES IMAX.) ACCESS PANEL I • W 1/2' ACC. 7/8' [22.21 1— I'I IIID/,/,./ 16521 ~ 1i _ 25-5/B 10.7/8 ♦ X 1/2' 210 118' [22.21 ~ C� _ ___ y _ LI • RETURN AIR • [2771 RETURNIA2M• (00311002'00Pi POWERS1 3/16'1[230 01 �(�AJ��I!•���:I�1£� 44 111, `�1 � ,. O,. FOR'TNAU-THE-RASEPAN'FACTORY OPTION, I [11171 • \� 2-5/8.J \� �� I FITTINGS FOR ONLY X.Y, 8 Z ARE PROMISED BACK [611 �+ �— `-Ir-- 1til Y9 '�' E ALT. I + SELECT EITHER 3/1'OR I/2' H YCUi;w CONDENSATE ' FOR POWER, DEPENDING ON WIRE SIZE �• WIDTH 1 'F DRAIN OPENING I7 3/1 _ C J •Y [1511 yM 1001)PROVIDES 3/1'FPT iHRU CURB IN BASEPAN SUPPLY 261/2 29-1/8 FLANGE 8 FITTING. Tel0. 18-1/8 , Z AIR EATS [7171 6DPPLY CA !1591 I \ + AIR 16-1/8 11-1/1 12-111 N I 11111 [36I31 [3121 SEE STITRUEC THE 6-111 CI .� 1 1 1 (, BASE CHART .` 1571 + y A.__,1 �//y/. A C ` ..LII— fi 3-3/0 I - ---. 12-1/8 1851 0 25 FLUE [3071 ON 16361 11001 HOOD 18-1/2 H .., X TOP [1701 y fp I o-v2 S 1-5/8 12651 1-111 81 til b+ 321 ELECTRICAL ., I-� __ DISCONNECT L-1 0 i —_ ' LOCATION .-- I CA i.J CONDENSER i== Vl COIL I,P-,---- r �� ACCESSL PANEL ACCCESS BLOWER CONDENSATE IL TER H _ DRAIN IO — • J �_— ® - -. [63818 Z _ OUTSIDE NSTALLED I_ _ , �- 19-1/2 OPTIONAL =.-......___ HANDLE 11-3/8 I. SUPPLr1A IA RETURN AIR (� INSTALLED - FACTORY _1-FFF CONVENIENCE —— 1 f 1191] DISCONNECT -M.—=..._ ; 12891 I' •• 21 1/1 L I OUTLET — = —— — •�� 6-518 ' 0-� [539] 11681 • 6-1/8 8.. �..8 I00 00 11551 I 3-3/1 8-3/8 6-5/8 1 HANDLE6 i 1951 1118/1 30-1/8 12111 f1691 11111 (1521 111871 [1611 26-218 71.318 [18881 16811 31-1/4 BAROMETRIC 17931 RELIEF F LOw LEFT SUPAIRPLY f RETURN FRONT AIR RIGHT SHEET DATE WINCEDES 582J 04-06 SINGLE ZONE ELECTRICAL REN 1 OF 2 08-14-14 - COOLING WITH GAS HEAT 48KC000284 _ o A N V 0 P.O.101.000 Tx D WI[S O0S5 005055(0 1000TYMs saa nE T 5 Ra 1OUEUNITED TECHNOLOGIES SYRACUSE,NI CONTENTSEDISCLOSED a USED nTxoul 05041!4 pA[ xt50Ca<a 5C.4 STD. UNIT CORNER CORNER CORNER CORNER CARRIER 11221 COXRUIOKS WRITTENCCC.G. HEIGHT UNIT WEIGHT WEIGHT(A) WEIGHT IBI WEIGHT IC) WEIGHT IDI • LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. K Y Z 582J 04 490 222 120 54 111 50 125 56 135 61 35 3/4 19081 21 3/4(6281 18 7/8 14791 582J 05 544 216 130 58 126 57 142 64 146 66 36 3/4 19331 24 3/4 16281 18 7/8 14791 582J 06 597 270 141 64 156 70 158 71 142 6/ 39 1/8 19931 23 1/2(5971 20 1/8(5111 A STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B A _ Z 0 1 .let N �/ ril• fso F. 7 0, Ro 14 CORNER D CORNER C tiC lJ c TOP y os 4 S Z W4 0 .1 C O..9 1.4 Z � CA et • °o 2 ,.. -- — 0 E� s......., . .. 1,..,00 �I� I 1 'l: : 00g FRONT SAMDATE SPUMESRRS 582J 04-06 SINGLE ZONE ELECTRICAL R(0 2 OF 2 08-14-14 - COOLING WITH GAS HEAT 48KC000284 _ _o A NO V 582J ROOF CURS NOTES: CONNECTOR PKG.AGC. GAS CONNECTION TYPE GAS FITTING POWER WIRING CONTROL WIRING ACCESSORY CONVENIENCE ACCESSORY p A 1.ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. FITTING FITTING OUTLET WIRING CONNECTOR ' 2.INSULATED PANELS:25.0 01 INK.POLYURETHANE FOAM,44.511-3/4]R DENSITY. CRRFCURB001A01 14 3.DIMENSIONS IN[J ARE IN MILLIMETERS. CRBTMPWR001A01 THRU THE CURB 3/4"[19]NPT [3.56] 4.ROOFCURB:18 GAGE STEEL. - 5.ATTACH DUCTWORK TO CURB.(FLANGES OF DUCT REST ON CURB). 3/4"[19]NPT 1/2"[12.7]NPT 1/2"[12.7]NPT CRRFCURB002A01 [610] 6.SERVICE CLEARANCE 4 FEET ON EACH SIDE. CRBTMPWR003AD1 THRU THE BOTTOM 1/2"[12.71 NPT 7.MO> DIRECTION OF AIR FLOW. B.CONNECTOR PACKAGE CRBTMPW RD01A01 IS FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWRO03A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. 1-3/4' (44.5) 1 Z 1.00" [25.01 11 3/41298.5)WIDE 5.42" 30.98' [137.7) 1303.87 INSULATED DECK PANELS, 21.14" '�1 [552.2] �:1 V, B 9/16'[217.5]WIDE I I INSULATED DECK PANEL .4 � k 1-3/4" TT __� 2\ [44A1 .1 , 1 __ ro* 1'413116' - EE NDTE p2• SECTION E-E SCALE 0.250 TRSTHEICU PLATE I [427]INSIDE III 2-318" 1 OI 70.87' THRU THE CURB [61] [1800.21 DRILL HOLE OZ 12'S0.8]@ I ��� O ASSEMBLY IIF I O REQUIRED) PRY RETURN AIR (SEE NOTE M8) r^ OPENING CA PC'S 355.0] 0 11316'[44.5] ', ./r 20 pr [3es.a1 E E 3,00" 21.86" Cl (76.2] 1554.11CD !"' �.. .� 32.19' ISN J ee.6) VIEW,"B" ti CORNER DETAIL / ` I'� 14.00' SUPPLY AIR 16.03" RETURN AIR -�/��1-316" 4 FA [355.6] OPENING [407 2) � / 14641til cc r441314' FNy `�`�144.51 r C 1.75" 20.41" 3.00' GASKE UNIT "A" II C III A (44.51 1518.3] [76.2) (SUPPLIED WITH CURB) d 13.78' 02. 1950A1 AIL(FIELD SUPPLIED) 5'7-3/8' 40.69" - DEC / TYPICAL(4)SIDES [1711.3] 110-33.51 (FIELD SUPPLIED) /j 7/16" CA 1171 (FIIELD SUPP • OUNTER LILIED)NG 3[904.6) `� A �/ �� ROOFING FELT SEE VIEW"13" OM(FIELD SUPPLIED) CERTIFIED DRAWING !T ANT STRIP • 17 0) '� (FIELD SUPPLIED) DRAWING RELEASE LEVEL 1,551 7 -OOFING MATERIAL PRODUCTION O \ \` (FIELD SUPPLIED) THIRD ANGLE �I UDIMENIOERSINLAES° PROJECTION 1f).-�-Iv °LERANCES ON. rx . II \\\\\\\\ 1 DEC im�a uaxta wrwn,4xnroswR ( I MATERIAL * AUTDTRL 3*EC F� TITro�>>xr wnmrxPNrtwnvR+FrgxouEnnry cannwuTrou. o VATIoN NUMBER AIR\ , / ` RIGID INSULATION - 1041738 CURB ASY,ROOF ///////////// LE % suF w RET VYVTVYY/V/Q\ (FIELD SUPPLIED) - ENGINEERING MANUFACTURING (004-007) j \\\ ENGINEERING REDUIREMENTS - DRAFTER CXECXER SIZE DRAWING MUDDED REV OVERALL DIM.5'.7 3)8'WAS 5-7 7/8,18GA T-005,Y-002 D 48TC400427 B % \ A MATERIAL WA 16 GA..NAIL FIELD SUPPLIED WAS 04/22/13 MMC 1067898 WEIGHT- MMC RA 06/17/11- SHEET 5 of 5 WITH CURB SURFACE FINISH MFGNURCH MODEL(INTERNAL USE ONLY) NEXT DRAWINGE DISTRIBUTION REV REVISION RECORD DATE BY CHKD AFRO ECU NO. - PORCH - N/AMMC n Iv 0 582J 577C--B LEGACY"' 14 SEER SINGLE-PACKAGED AIR CONDITIONER ANI)G:AS FURNACE SYSTEM WITH PURON (IL-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS(SIZES 24-60) Product Data Convertible duct configuration 0(10(T-1--_-- ii ......‘,N........... --- Unit is designed for use in either downflow or horizontal �� applications. Each unit is converted from horizontal to downflow II`.. — = and includes two horizontal duct covers. Downflow operation is I. provided in the field to allow vertical ductwork connections.The 111,111L0 basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design offers SEER (Seasonal Energy Efficiency Ratios)of 14.2 to 14.5, 12.0 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings up to 1 81.0%. 1 Energy-saving,direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit I \ / for propane conversion is available for all units. � Low NOx units are designed for California installations. These pi O O models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped A09034 from the factory and MUST be installed in California Air Quality Fig.1- Unit 577C--B Management Districts and wherever a Low NOx rule exists. Single-Packaged Products with Energy-Saving Features and Durable, dependable components Compressors are designed Puron0O refrigerant. for high efficiency.Each compressor is hermetically sealed against • 14.2 to 14.5 SEER contamination to help promote longer life and dependable • 12.0 EER operation. Each compressor also has vibration isolation to provide quieter operation.All compressors have internal high pressure and • 81.0%AFUE(Single phase models) overcurrent protection. • Factory-Installed TXV Monoport inshot burners produce precise air-to-gas mixture, • ECM Motor-Standard which provides for clean and efficient combustion. The large • Direct Spark Ignition monoport on the inshot(or injection type)burners seldom,if ever, • Low Sound Levels requires cleaning.All gas furnace components are accessible in one • Dehumidification Feature compartment. FEATURES/BENEFITS Turbo-tubular'''' heat exchangers are constructed of aluminized steel for corrosion resistance and optimum heat transfer for One-piece heating and cooling units with low sound levels, easy improved efficiency.The tubular design permits hot gases to make installation,low maintenance,and dependable performance. multiple passes across the path of the supply air. Puron is Bryant's unique refrigerant designed to help protect the In addition,dimples located on the heat exchanger walls force the environment.Puron is an HFC refrigerant which does not contain hot gases to stay in close contact with the walls, improving heat chlorine that can harm the ozone layer. Puron refrigerant is in transfer. service in millions of systems proving highly reliable, environmentally sound performance. ECM Motor is standard on all models. Easy Installation Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and Factory-assembled package is a compact, fully self-contained, provide for cooing operation down to 40°F (4.4°C) outdoor combination gas heating/electric cooling unit that is prewired, temperature. Motormaster® II low ambient kit is available as a pre-piped, and pre-charged for minimum installation expense. field-installed accessory. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet Thermostat control residential and light commercial requirements. Units are Time Guard® II anti-short cycle protection circuitry. If a lightweight and install easily on a rooftop or at ground level.The non-corporate thermostat without anti-short cycle protection is high tech composite base eliminates rust problems associated with used the Time Guard II field-installed anti-short cycle kit is ground level applications. recommended. Innovative Unit Base Design On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold,algae and bacterial growth.On the outside metal base rails provide added stability as well as easier handling and rigging. 1 MODEL NUMBER NOMENCLATURE 577C N W B 24 000 A A -- Variations Type of Unit FE—Economizer(3 Phase Only) 577C—Single Pack- GP—Base unit with tin plated indoor coil hairpins) aged Air Conditioner and Gas Furnace and Stainless SSteel HX (Single Phase Only GS—Stainlesecs Steel HX SE—Economizer and Stainless Steel HX(3 Phase Only) Electrical Supply TF—Filter Rack N—208/230-1-60 TP—Base unit with tin plated indoor coil hairpins (Single P—208/230-3-60 Phase Only E—460-3-60 See Price Page for full list of factory options. Fuel and Controls Only used if ordering an option W—Natural Gas Minor Series Major Series Brand Name A—Common Unit Nominal Cooling Capacity 24—2.0 Tons Heat Input Size(Btuh) 30-2.5 Tons 36—3.0 Tons 040—40,000 m 060—60,000 42—3.5 Tons 48-4.O Tons 11095—gg000 60—5.0 Tons 110—117,000 130—127,000 or 130,000 l!7 GAS-FIRED j a CERTIFIED 11 WDAE Use of the AHRI Coated TM Mara i a Datesatesa manufacturer's c UL r u$ C ma u$ participation in the COMP�IRNT © program Forverdcatun of certification for individual LISTED LISTED products ua s;d,enorv.org. ENERGY STAR 3 AHRI* CAPACITIES Cooling Capacities and Efficiencies UNIT SIZE NOMINAL STANDARD COOLING EER SEER TONS CFM CAPACITY 24 2 800 23600 12.0 14.5 30 2.5 1000 28600 12.0 14.5 36 3 1200 34200 12.0 14.5 42 3.5 1400 41000 12.0 14.5 48 4 1600 47000 12.0 14.2 60 5 1750 57000 12.0 14.2 LEGEND Notes: dB-Sound Levels(decibels) 1. Ratings are net values,reflecting the effects of circulating fan heat. db-Dry Bulb Ratings are based on: SEER-Seasonal Energy Efficiency Ratio Cooling Standard:80°F(26.7°C)db,67°F wb(19.4°C)indoor entering-air wb-Wet Bulb temperature and 95°F db(35°C)outdoor entering-air temperature. COP-Coefficient of Performance 2. Before purchasing this appliance,read important energy cost and effi- *Air Conditioning,Heating&Refrigeration Institute. ciency information available from your retailer. **At"A"conditions-80°F(26.7°C)indoor db/67°F(19.4°C)indoor wb& m 95°F(35°C) outdoor db. I t Rated in accordance with U.S.Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240. U h. Gas Heating Capacities and Efficiencies,Single Phase Models N- u) OUTPUT CAPACITY TEMPERATURE RISE UNIT SIZE HEATING INPUT(Btuh) (Btuh) RANGE°F (°C)24040 25-55 AFUE(%) 30040 40,000 33,000 (14-31) 81.0 24060 30060 25-55 36060 60,000 49,000 (14-31) 81.0 42060 36090 73,000 42090 74,000 35-65 48090 90,000 74,000 (19-36) 81.0 60090 74,000 48115 30-60 60115 115,000 94,000 (17-33) 81.0 48130 35-65 60130 127,000 104,000 (19-36) 81.0 LEGEND AFUE-Annual Fuel Utilization Efficiency NOTE:Before purchasing this appliance,read important energy cost and efficiency information available from your retailer. Gas Heating Capacities and Efficiencies,Three Phase Models UNIT SIZE HEATING INPUT(Btuh) OUTPUT CAPACITY TEMPERATURE RISE AFUE(%) (Btuh) RANGE°F (°C) 24040 30040 40,000 32,000 (30_33) 80.0 24060 48,000 80.0 30060 48,000 25-55 80.0 36060 60,000 48,000 (14-31) 80.0 42060 47,000 78.5 36090 72,000 79.3 42090 73,000 35-65 80.4 48090 90,000 73,000 (19-36) 80.4 60090 73,000 80.4 48115 60115 115,000 93,000 (107 33) 80 .3 48130 . 35-65 60130 _ 130,000 103,000 (19-36) 78.9 LEGEND AFUE-Annual Fuel Utilization Efficiency NOTE:Before purchasing this appliance,read important energy cost and efficiency information available from your retailer. A-Weighted Sound Power Level (dBA) SOUND TYPICAL OCTAVE BAND SPECTRUM(without tone adjustment) UNIT SIZE RATING 1 125 250 500 1000 2000 4000 8000 24 76 58.0 65.5 71.5 71.0 65.5 60.5 53.0 30 ▪ 73 62.0 64.0 67.5 67.5 65.0 60.0 54.5 36 76 64.5 66.5 70.0 70.0 67.5 61.0 54.0 42 77 70.5 68.0 70.5 70.5 68.0 62.5 58.0 48 ▪ 77 71.5 65.0 71.0 67.5 67.5 63.0 57.5 60 ▪ 77 73.5 65.5 68.5 67.5 66.5 62.0 58.0 ' NOTE:Tested in accordance with AHRI Standard 270-1995(not listed in AHRI). 4 , . PHYSICAL DATA UNIT SIZE 24040 24060 i 30040 30060 36060 36090 42060 T 42090 NOMINAL CAPACITY(ton) . • 2 2 2-1/2 2-1/2 3 3 3-1/2 . 3-1/2 SHIPPING WEIGHT**lb. i 337 337 1---349 349 383 383 472 , 472 SHIPPING WEIGHT**(kg) . 153 153 158 158 174 174 214 214 COMPRESSOR/QUANTITY Scroll/1 REFRIGERANT(R-410A) ; i - Quantity lb. . . 6.0 6.0 5.6 5.6 9.5 : 9.5 8.8 ! 8.8 Quantity(kg) 2.7 2.7 2.5 2.5 4.3 : 4.3 4.0 ! 4.0 REFRIGERANT METERING DEVICE TXV OUTDOOR COIL . , Rows...Fins/in. ! 1..21 1...21 1...21 1...21 2..21 2...21 2..21 2...21 Face Area(sq ft) 11.9 11.9 13.6 13.6 15.4 15.4 13.6 : 13.6 OUTDOOR FAN 1 1 Nominal CFM 2500 2500 2700 2700 2800 2800 3000 3000 Diameter in. . 24 24 24 24 24 ' 24 26 26 Diameter(mm) : 609.6 609.6 609.6 609.6 609.6 609.6 660.4 660.4 Motor Hp(Rpm) i 1/10(810) 1/10(810) 1/10(810) 1/10(810) 1/5(810) 1/5(810) 1/5(810 1/5(810) INDOOR COIL Rows...Fins/in. 1 3...17 3...17 3...17 3...17 3...17 i 3...17 3...17 3...17 CO Face Area(sq ft) 3.7 3.7 3.7 3.7 3.7 ! 3.7 4.7 . 4.7 INDOOR BLOWER Nominal Cooling Airflow(Cfm) 800 800 1000 1000 1200 1200 1400 1400 0 Size in. 10x10 10x10 10x10 10x10 11x10 11x10 11x10 11x10 r,.. Size(mm.) 254x254 254x254 254x254 254x254 279.4x254 279.4x254 279.4x254 279.4x254 r-- in Motor HP(RPM) 1/2(1050) 1/2(1050) 1/2(1050) 1/2(1050) 3/4(1000) 3/4(1000) 3/4(1075) 3/4(1075) FURNACE SECTION* 1 , Burner Orifice No.(Qty...Drill Size) 1 Phase Natural Gas(Factory Installed) 2...44 3...44 2...44 3..44 3..44 3...38 3...44 3...38 1 Phase Propane Gas 2...55 3...55 2...55 3...55 3...55 3...53 3...55 3...53 3 Phase Natural Gas(Factory Installed) 2...44 2...38 2...44 2...38 2...38 3...38 2...38 3...38 3 Phase Propane Gas 2...55 2...53 2...55 2...53 2...53 3...53 2...53 3...53 HIGH-PRESSURE SWITCH 650+/-15 (psig)Cut-out Reset(Auto) 420+/-25 LOSS-OF-CHARGE/LOW-PRESSURE 20+/-5 SWITCH(Liquid Line)(ps1g)cut-out Reset 45+/-10 (auto) RETURN-AIR FILTERStt • 1 Throwaway Size in. i 20x20x1 20x24x1 24x30x1 (mm) , 508x508x25 508x610x25 610x762x25 - UNITSIZE 48090 48115 48130 60090 1 60115 1 60130 NOMINAL CAPACITY(ton) , 4 4 4 5 5 , 5 SHIPPING WEIGHT**lb 490 490 490 518 518 518 SHIPPING WEIGHT**kg . 222 222 222 235 235 235 COMPRESSOR/QUANTITY Scroll/1 REFRIGERANT(R-410A) • • Quantity lb :• • . 9.4 9.4 9.4 12.5 12.5 12.5 Quantity(kg.) ! 4.3 4.3 4.3 5.7 5.7 I 5.7 REFRIGERANT METERING DEVICE TXV OUTDOOR COIL Rows...Fins/in. 2...21 2...21 2...21 2...21 2...21 2..21 Face Area(sq ft) 17.5 17.5 17.5 21.4 21.4 21.4 OUTDOOR FAN Nominal Cfm 3200 3200 3200 3600 3600 3600 Diameter in. 26 26 . 26 26 26 26 Diameter(mm) 660.4 660.4 660.4 660.4 660.4 660.4 Motor Hp(Rpm) ! 1/5(810) 1/5(810) 1/5(810) 1/5(810) 1/5(810) 1/5(810) INDOOR COIL Rows...Fins/in. 3...17 3...17 3...17 3...17 3...17 3...17 Face Area(sq ft) 4.7 4.7 4.7 5.7 5.7 5.7 INDOOR BLOWER 1600 1600 1600 1750 1750 Nominal Cooling Airflow(Cfm) 1750 11x10 11x10 11x10 11x10 11x10 Size in. 11x10 279.4x254 279.4x254 279.4x254 279.4x254 279.4x254 Size(mm) Motor HP(RPM) 279.4x254 1.0(1075) 1.0(1075) 1.0(1075) 1.0(1040) 1.0(1040) 1.0(1040) FURNACE SECTION* Burner Orifice No.(Qty...Drill Size) 1&3 Phase Natural Gas(Factory Installed) 3...38 3...33 3...31 3...38 3...33 3...31 1&3 Phase Propane Gas 3...53 3...51 3...49 3...53 3...51 ., 3...49 •' HIGH-PRESSURE SWITCH 650+/-15 (psig)Cut-out Reset(Auto) 420+/-25 LOSS-OF-CHARGE/LOW-PRESSURE 20+/-5 SWITCH(Liquid Line)(psig)cut-out Reset 45+/-10 (auto) RETURN-AIR FILTERS Throwawayll in. 24x36x1 (mm) 610x914x25 *Based on altitude of 0 to 2000 ft(0-610 m). f Required filter sizes shown are based on the larger of the AHRI(Air Conditioning Heating and Refrigeration Institute)rated cooling airflow or the heating air- flow velocity of 300 ft/minute for throwaway type.Air filter pressure drop for non-standard filters must not exceed 0.08 IN.W.C. , $If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity. **For 460 volt units,add 14 lbs(6.35 kg)to the shipping weight. 5 577C--B UNIT ELECTRICAL UNIT WT. UNIT HEIGHT IN/MM CENTER OF GRAVITY IN/MM - CHARACTERISTICS LB KG "A" X Y Z ����-----yyy1 577068824)041/06011A/NIA 208/230-1-60 330 149.6 42-1/8 1070 22-13/16 579 4 15-5/16 388-9 15-11/16 398-5 ^9 577CIN/PIW830(040/060)(A/N)A 208/230-1, 208/230-3-60 342 155.0 44-1/8 1121 22-13/16 579-4 15-5/16 388.9 15-13/16 401.6 577CIN/P19(836(060/090)12/N)A 208/230-1, 208/230-3-60 376 170 4 46-1/8 1172 22-13/16 579 4 15-5/16 388.9 16 5/8 422.3 577CEWB361060/090)(A/N)A 460-3-60 390 116.8 46-1/8 1112 22-13/16 579.4 15-5/16 388.9 16-5/8 422.3 d 4 UNITS VOLTAGE LB/KG z CORNERWEIGHT 1.. ,2.. 3.. .4.. 577CNW824(040/0601(A/610 208/230 49.5 22.5 66.0 29-9 98-9 44.9 115.4 52.4 GI) 577C(N/P)W830(040/06011A/NIA 208/230 51.3 23.3 68-4 31 0 102 5 46 5 119 6 54 3 I"4 5770N/P1 W836)080/09011A/N)A 208/230 56.4 25.6 75.2 34.1 112 7 51.2 131.5 59.7 7 915/16-2t 9n6� 915/16 577CEWB36(060/0901(0/N)0 460 56 4 25.6 75.2 34.1 121 7 55 3 136 5 62 0 1252.4) 1547 1] [25/41 3-'/16-..-"' 11 NOTE ALL TABLE DATA RELEVANT FOR ALL FACTORY INSTALLED . REOUIRED CLEARANCES TO COIUIBUSTIBLE MAIL. OPTIONS EXCEPT ECONOMIZER 2 3r4� INCHES (MMI N N 169 91 RETURN SUPPLY DUCTTOROF SIDEIT OF UNIT 1NC2 150.8] W s ;__-_-p. SIDE OPPOSITE DUCTS 14 1355.61 01 I OPTIONAL �- : OPTIONAL :r BOTTOM OF UNIT 1/2 [12.7] 1 RETURN �� SUPPLY FLUE PANEL. 36 1914.4] 9,54-,,R4"8'7 AIR /� \\ AIR 4, OPENING OPENING I. NEC.REQUIRED CLEARANCES. I' (lll(lllli�f�� 1111u) . I 41 INCHES [MM] '' -11,1;\ BETWEEN UNITS, POWER ENTRY SIDE 42 [1066-8] y��,1��11������ �'i- 3.3/16 UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE 36 [914.0] Z_____\\�� _ it -Y J E 81.01 OUTDOOR COIL UNIT AND BLOCK OR CONCRETE WALLS AND OTHER 'i, \�,�: _ j - i GROUNDED SURFACES, POWER ENTRY SIDE 42 [1066.8] j i^ - __ M 4�-7"6,1 [,52.41 REOURED CLEARANCE FOR OPERATION AND SERVICING ¢�_`� �►�. -7"6,1INCHES (MM] ® } EVAP COIL ACCESS SIDE 36 1914 0] \\�0 POWER ENTRY SIDE .. 42 [1066.8] (EXCEPT FOR NEC REQUIREMENTS) INDOOR COIL UTD00R COIL UNIT TOP ... . _.48 [1219-2] TOP VIEW SIDE OPPOSITE DUCTS 36 1914 01 co DUCT PANEL 12 [304 81* *MINIMUM DISTANCES-IF UNIT IS PLACED LESS THAN 12 [304.8] FROM WALL * SYSTEM,THEN SYSTEM PERFORMANCE MAYBE COMPROMISED. 47 DIMENSIONS IN 11 ARE IN MM 31.7/16 1 [1193 8] 1798 51 f-4.1/2 125 4] [114 3] IIII'II'�I I1IHNIIHNIHO1 AELECTRICAL CCESS PANEL lIIIIIIIIIIIIlL -llllllllle' f28 POWER AENTRY 1111IIIIIIIIIY . __- 4-7/8 7/8' [22 2)DIA. HOLE -- IPAIIN1123 BI CONTROL ENTRY A' • 1.1 81111 SUPPLY RETURN ®� 15-7/R� DUCT • DUCT • 1 urn I - 103116 I [40 .2] J OPENING - OPENING 3-5/8 T43613/1621 "27(950165 '5'5/a 7192.11 . [396 91 1, [258.8] f!I{QYQII 0 A_ ',1 V• •0• W� 1l^!a-_ _ 0.0 16166.76] 0.0 .1-,. 1 I. 0.0 12-13/16 C0476(5509 BLOWER 4-13/16 3/16 f 1325 dl PANEL "4' PANEL [112.11 [4.8] 1l2" 112 11 N.P 3-7/16 F �5/8 2-1/16 N- GAS ENTRY 187 31 828 7 48-3/16 152 41 - . 9-7/8 21-5/8--.- 9-7/8 -.- DRAIN DRAIN OUTLET [1224.01 1-13/16 [250 RI 1549.31 f250 81 }'4. ["11 ) P' LEFT SIDE VIEW 146 01 RIGHT SIDE VIEW REAR VIEW 4 ,/R' [22 21 DEEP FRONT VIEW n A REV 48VL500348 ACCESSORY DIMENSIONS . ,�\ B Damsel tines sFow:toss support �,/ localim tar large Casepan units. HVAC unit - HVACbasepan uCo C /� --- HvAc ifs Znit 1 Sealing -" Gasket ............._ . .... t Roofcurb '� / r' , ll Anchor sorawi � �l Wood nailer" �\ / Flashing field i �� j supplied Roofcurb` / \\, / /1-'-'' Insulation / ` . / // (field supplied) `-------,,...,/ / Roofing material �- / j field supplied �v / E Cant strip D / field supplied " / CO 0 W =_-�A SMALL/COMMON CURB / A09413 'Provided with roofcurb N. A09090 In ROOF CURB DETAIL /'''B — — )— 4 i - C ' ' � SMALL utlPPL1Y BASE / 41111110p.-----..„,,,,...„,,_ .i )17 1 Alp T F A il 41%11pr LARGE j 4 RPYURN BASE ` • E AIR UNIT DI UNIT PLACEMENT ON COMMON CURB A09094 i LARGE CURB A09415 SMALL OR LARGE BASE UNIT A09414 (smallA common Blare C D E F UNIT CATALOG B IN. base) base)aIN. N. IN. IN. G H SIZE NUMBER IN.(mm) IN.(mm) (mm) IN.(mm)* IN.(mm)* (mm) (mm) (mm) (mm) SmalloCPRFCURB010A00 (279) 10(254) 324. 14 (822) 30.6(778) Large CPRFCURB011A00 (356) 16 47.8 11 14(356) (406) (1214) 2.7(69) 46.1 (1170) CPRFCURB012A00 (279) 14 43.9 Large ( )356 42.2(1072) CPRFCURB013A00 14 (1116) (356) *Part Numbers CPRCURB010A00 and CPRCURB011 A00 can be used on both small and large basepan units.The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1. Root curb must be set up for unit being installed. 2. Seal strip must he applied,as required,to unit being installed. 3. Roof curb is made of 16-gauge steel. 4. Attach ductwork to curb(flanges of duct rest on curb). 5. Insulated panels:I-in.(25.4 mm)thick fiberglass I lb.density. 10 COMMERCIAL Model 579F1580.D ILItiyant \ SINGLE PACKAGE ROOFTOP Sizes 036-300° GAS HEATING/ELECTRIC COOLING UNITS 3 to 25 Tons I`— ,______Tr \ __ ____ P II 11.11 � v J ,A T 4111111111111111111111.1111- 58 0 D036-072 580D036-072 579F180,216 , a s _ I — rt. 1 IIU /I ...-------•.......,...........<.... . . • 0 ___..... ........_......:.... 011 N.Jr. IIr 580D090-150 579F240,300 Standard-Efficiency Rooftop Units with: INTEGRATED GAS UNIT CONTROLLER (IGC) (All Models) • Exclusive integrated gas control board with diagnostics — All ignition components are contained in the compact IGC • AlumagardTm heat exchanger coating which is easily accessible for servicing.The IGC control board, • Induced-draft fan for gas combustion designed and manufactured exclusively for Bryant rooftop units, • Tubular, dimpled heat exchangers provides built-in diagnostic capability An LED (light-emitting di- • Pre painted galvanized steel cabinet for long life and quality ode)simplifies troubleshooting by providing visual fault notifica- appearance • Commercial strength baserails with built-in rigging capability tion and system status confirmation. • Convertible design for horizontal supply/return The IGC also contains an exclusive anti-cycle protection for gas • Non-corrosive,sloped condensate drain pan,meets ASHRAE heat operation. After 4 continuous cycles on the unit high- 62-89 (IAQ) temperature limit switch,the gas heat operation is disabled,and • Two-inch return-air filters • A wide assortment of factory-installed options available, in- an error code is issued This feature greatly improves reliability eluding high static drives that provide additional performance of the rooftop unit. range FEATURES/BENEFITS Every compact one-piece unit arrives fully assembled,charged, tested, and ready to run. Form No. PDS 580D.36.8 MODEL NUMBER NOMENCLATURE 580D036-150 MODELS ONLY 580D E V 090 180 C B11111 580D —Packaged Rooftop Evaporator-Fan Motor Options Standard Efficiency A--Standard Motor and Drive Gas/Electric Unit B--Alternate Motor and/or Drive Voltage Designation Facto Installed Outdoor-Air and J --208/230-1-60 Factory- Installed --208/230-3-60 Other Upgrade Options E--460-3-60 A--Standard Unit T--575-3-60 C--Durablade Economizer H--25%Manual Damper Fuel and Control Type M--Durablade Economizer,Controls V--Natural Gas/Direct Spark Ignition Upgrade Package*,arrd Condenser • Coil Grille Nominal Tons N--25%Manual Damper,Controls 036--3 090--7-1/2 Upgrade Package*,and Condenser 048—4 102--8-1/2 Coil Grille 060—5 120--10 T—Controls Upgrade Package*,and 072—6 150-- 12-1/2 Condenser Coil Grille P--Parablade Economizer Gas Heat Input(Btuh) L--Parablade Economizer,and 074--74,000 180--180,000 Controls Upgrade Package 115-- 115,000 224--224,000 K--Parablade Economizer,Controls 125-- 125,000 250--250,000 Upgrade Package,and Condenser 150— 150,000 Coil Grille *Contains high pressure, (loss-of-charge) low-pressure,and freeze protec- tion cutout switches. NOTE:The example model number 580DEV090180CB designates a 7' ton 460-3-60 volt gas/electric rooftop unit with 180,000 !Ruh natural gas heat, Durablade economizer,and alternate drive fill 4 r ARI* CAPACITY RATINGS NOMINAL STANDARD NET COOLING TOTAL SEERt SOUND UNIT 5800 TONS CFM CAPACITY kW Belt Drive ' Direct Drive RATING (Btuh) (Bels) 036 3 1200 35,000 4.0 10.0 9 7 8 210 048 4 1600 47,000 5.5 10 0 9 7 8.2 - 060 5 2000 57,000 6 7 10 0 9 7 8 2 NET COOLING SOUND UNIT NOMINAL STANDARD TOTAL CAPACITY EER RATING IPLV TONS CFM kW (Btuh) (Bela) 5800072 6 2100 72,000 8.0 9.0 8 2 "" 580D090 71 2800 85,000 9.6 8.9 8.6 9.35 5800102 81/2 3000 99,000 _ 11.0 9 0 8.6 9.00 5800120 10 4000 117,000 13 0 9 0 8 8 9 35 580D150 121/2 4500 145,000 16.1 9.0 8 8 9 20 579F180 15 5250 178,000 20 7 8 6 8.8 10.70 579F216 18 6000 190,000 21 3 8 9 9.0 9.20 579F240 20 6200 222,000 25.5 8.6 9 5 8 80 _ - 579F300 25 7200 268,000 31 4 8 5 9 5 8 40 LEGEND Bels — Sound Levels(1 bel=10 decibels) db — Dry Bulb EER — Energy Efficiency Ratio IPLV — Integrated Part-Load Values SEER — Seasonal Energy Efficiency Ratio wb — Wet Bulb *Air Conditioning and Refrigeration Institute tApplies only to units with capacity of 65,000 Btuh or less **The IPLV applies only to two-stage cooling units NOTES: 1MP 1 Rated in accordance with ARI Standards 210/240-89(for sizes 036-120)or 360-89(for sizes 150-240)and 270-89 2 The 579F300 is beyond the scope of the ARI certification program I 3 ARI ratings are net values, reflecting the effects of circulating fan heat 4 Ratings are based on: • I 61 .;iSi ,,, -,,, 9'vl Cooling Standard:80 F db,67 F wb indoor entering-air temperature and 95 F db air entering outdoor unit IPLV Standard: 80 F db,67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature (a I 6 ARI*CAPACITY RATINGS (cont) HEATING CAPACITIES AND EFFICIENCIES-580D036-150 HEATING INPUT TEMPERATURE STEADY-STATE CALIFORNIA UNIT 580D (Btuh) OUTPUT CAPACITY AFUE SEASONAL RISE EFFICIENCY EFFICIENCY Stage 2/Stage 1 (Btuh) (F) (o�) (�*) (%) 036 074 -1 72,000 59,200 25-55 80 0 80 0 77 2 036 115 115,000/ 82,000 92,000 55-85 80 0 80 0 76.7 048 074 -/ 72,000 59,200 25-55 80 0 80 0 77.2 048 115 -/115,000 92,000 35-65 80 0 80 0 77 1 048 150 150,000/120,000 120,000 50-80 80 0 80 0 76 9 060 074 -/ 72,000 59,200 25-55 80 0 BO 0 77 2 060 115 -/115,000 92,000 35-65 80 0 80 0 77 1 060 150 150,000/120,000 120,000 50-80 80 0 80 0 76 9 072 074 -/ 72,000 59,200 25-55 80 0 80 0 77 2 072 115 -/115,000 92,000 35-65 80 0 80 0 77 1 072 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 090 125 -/125,000 100,000 20-50 80.0 80 0 75 8 090 180 180,000/120,000 144,000 35-65 80 0 80 0 77 1 090 224 224,000/180,000 179,200 45-75 80 0 80 0 77 1 102 125 -/125,000 100,000 20-50 80 0 80 0 75 8 102 184 180,000/120,000 144,000 35-65 80 0 80 0 771 102 224 224,000/180,000 179,200 45-75 80 0 80 0 77.1 120 180 180,000/120,000 144,000 35-65 80 0 80.0 771 120 224 224,000/180,000 179,200 35-65 80 0 80 0 77 1 120 250 250,000/200,000 200,000 40-70 80 0 80 0 76 4 150 224 224,000/180,000 179,200 35-65 80 0 80 0 771 150 250 250,000/200,000 200,000 40-70 80 0 80.0 76 4 LEGEND ' AFUE-Annual Fuel Utilization Efficiency NOTE: NOx levels are 40 nanogramsfjoule or less with the accessory NOx reduction kit(sizes 036-060). HEATINGINPUT CAPACITIES AND EFFICIENCIES-579F180-300 TEMPERATURE STEADY-STATE MINIMUM 4111 HEATINGOUTPUT CAPACITY RISE EFFICIENCY HEATING UNIT 579E (Btuh) Btuh ( ) FM Stage 2/Stage 1* (F) (%) C 9 9 180 230 230,000/172,000 186,000 15-45 81 0 3800 180 300 300,000/225,000 243,000 30-60 81.0 3800 216 275 275,000/206,000 223,000 15-45 81.0 4750 216 360 360,000/270,000 292,000 20-50 81.0 5450 240275 275,000/206,000 223,000 15-45 81.0 4750 240 360 360,000/270,000 292,000 20-50 81.0 5450 300 275 275,000/206,000 223,000 15-45 81 0 4750 300 360 360,000/270,000 292,000 20-50 81 0 5450 'All units are 2-stage heat. NOTE: Minimum allowable temperature of mixed-air entering the heat exchanger during first-stage heating is 45 F There is no minimum mixed-air temperature limitation during second-stage heating For entering-air temperatures below 45 F both stages of heat must be energized together to minimize condensation issues and to ensure proper unit operation Iiiil 7 ;, . . , 7 1 PHYSICAL DATA-580D036-072 UNIT SIZE 58013 036 048 060 072 NOMINAL CAPACITY(tons) 3 4 5 6 0 . OPERATING WEIGHT(lb) Unit AI/AI" 460 470 490 565 AI/Cu' 465 476 497 576 Cu/Cu* 468 482 505 587 Economizer Durablade 34 34 34 34 Parablade 42 42 42 42 Roof Curbt 115 115 115 115 COMPRESSOR Hermetic Quantity 1 1 1 1 No.Cylinders(per Circuit) 2 2 2 2 Oil(oz) 50 50 50 54 REFRIGERANT TYPE R-22 Expansion Device AcutrolTM Feed Device Operating Charge(Ib-oz) Circuit 1 3-6 4-11 5-13 7-8 Circuit 2 — — — — CONDENSER COIL Enhanced Copper Tuber,Aluminum Lanced Fins Rows...Fins/in. 1 .17 1 17 1 17 2 17 Total Face Area(sq ft) 7 36 11 39 13 19 10.42 CONDENSER FAN Propellor Type Nominal Cfm 3500 4000 4000 4000 Quantity...Diameter(in.) 1 22 0 1 22.0 1 .22 0 1 22 0 Motor Hp...Rpm 1/4.1100 1/4. 1100 1/4. 1100 1/4 1100 Watts Input(Total) 325 325 325 325 EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double-Wavy Fins Rows...Fins/in. 2 15 2 15 3 15 4 15 Total Face Area(sq ft) 4.17 5 5 5 5 5.5 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) Std 1 10 x 10 1 10 x 10 1 11 x 10 1 10 x 10 Alt 1..10x10 1 .10x10 1 .10x10 — Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt Nominal Cfm 1200 1600 2000 2400 Motor Hp Std — — — — II Alt — — — — Maximum Continuous Bhp Std 34 75 1 20 2 40 Alt 100 100 180 — Motor Frame Size Std 48 48 48 56 Alt 48 48 48 — Nominal Rpm High/Low Std 860/800 1075/970 1075/970 — Alt — — — — Fan Rpm Range Std — — — 1070-1460 Alt 760-1000 835-1185 900-1300 — Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max(in.) Std — — — 2 8/3 8 Alt 1 9/2.9 1 9/2 9 2 4/3 4 — Nominal Motor Shaft Diameter(in.) Std ih y2 1/2 We Alt 1/2 1/2 1/2 — Fan Pulley Pitch Diameter(in.) Std — — — 4 5 Alt 45 40 45 — Nominal Fan Shaft Diameter(in.) — — — — Belt,Quantity...Type...Length(in.) Std — — — 1 .A 40 Alt 1 A 34 1 A 34 1 A 39 — Pulley Center Line Distance(in.) Std — — — 14 7-15 5 Alt 10 0-12 4 10 0-12 4 14 7-15 5 — Speed Change per Full Turn of Std — — — 80 Movable Pulley Flange(rpm) Alt 48 70 80 — Movable Pulley Maximum Full Turns Std — — — 5 From Closed Position Alt 5 5 5 — Factory Setting Std — — — 3 Alt 3 3 3 — Factory Speed Setting(rpm) Std — — — 1225 Alt 856 975 1060 — Fan Shaft Diameter at Pulley(in.) 1/1 1/2 1/2 1/2 LEGEND **Rollout switch lockout is manually reset by interrupting power to unit Al — Aluminum or resetting thermostat. Bhp — Brake Horsepower ttRequires an optional or accessory Controls Upgrade Kit Cu — Copper NOTE: The 580D036-150 units have a loss-of-charge/low-pressure *Evaporator coil fin material/condenser coil fin material Contact your switch(accessory or option)located in the liquid line local representative for details about coated fins tWeight of 14-in roof curb 8 PHYSICAL DATA—580D036-072 (cont) 036 048 060 072 UNIT SIZE 580D MEDIUM/ LOW/MEDIUM/ LOW/MEDIUM/ LOW/MEDIUM/ 110 HIGH HEAT HIGH HEAT HIGH HEAT HIGH HEAT FURNACE SECTION Rollout Switch Cutout Temp(F)** 195 195 195 195 Burner Orifice Diameter (in....drill size) Natural Gas Std 113 33 .113 33/113. 33/.129 30 113 33/113 33/129 .30 113 33/113 33/.129 30 Liquid Propane Alt 089 .43 089 43/089 43/.102.38 089 43/089 43/102.38 089 43/089 43/102.38 Pilot Orifice Diameter (Quantity)in. ...drill size Natural Gas Std — — — — Liquid Propane Alt — — — — Thermostat Heat Anticipator Setting(amps) 0 v and 575 v Stage 1 14 14 14 14 Stage 2 .14 14 14 14 460 v Stage 1 .14 .14 14 t4 Stage 2 14 14 14 14 Gas Input(Btuh) Stage 1 72,000/82,000 72,000/115,000/120,000 72,000/115,000/120,000 72,000/115,000/120,000 Stage 2 —/115,000 —/—/150,000 —/—/150,000 —/—/150,000 Efficiency(Steady State)(%) 80 80 80 80 Temperature Rise Range 25-55/55-85 25-55/35-65/50-80 25-55/35-65/50-80 25-55/35-65/50-80 Manifold Pressure(in.wg) Natural Gas Std 3 5 3 5 3 5 3 5 Liquid Propane Alt 3 5 3 5 3 5 3 5 Gas Valve Quantity 1 1 1 1 Gas Valve Pressure Range Psig 0 180-0 487 0 180-0 487 0 180-0 487 0 180-0 487 in.wg 5 0-13 5 5 0-13.5 5 0-13 5 5 0-13 5 Field Gas Connection Size(in.) 1/2 1/2 1/2 1/ HIGH-PRESSURE SWITCH (psig)tt Standard Compressor 450±50 500±50 Internal Relief(Differential) Cutout 428 428 Reset(Auto.) 320 320 LOW-PRESSURE SWITCH (psig)tt Cutout 7±3 Reset(Auto.) 22±7 FREEZE PROTECTION THERMOSTAT(F)** Opens 30±5 Closes 45±5 OUTDOOR-AIR INLET SCREENS Cleanable Quantity...Size(In.) 1 20 x 24 x 1 RETURN-AIR FILTERS Throwaway Quantity...Size(in.) 2 16 x 25 x 2 LEGEND "Rollout switch lockout is manually reset by interrupting power to unit Al — Aluminum or resetting thermostat Bhp — Brake Horsepower ttRequires an optional or accessory Controls Upgrade Kit Cu — Copper NOTE: The 580D036-150 units have a loss-of-charge/low-pressure *Evaporator coil fin material/condenser coil fin material Contact your switch(accessory or option)located in the liquid line local representative for details about coated fins 1-Weight of 14-in roof curb 9 BASE UNIT DIMENSIONS—580D036-072 40 0'-1 13/16' % D'-1 5/8' 1.-0' CONTROL CORNER WEIGHT' [46 51 [4U 13051 UNIT / A 8 C 0 — 0'-8'---I 030D lb kg lb kg lb kg [203) 036 144 0 63.3.5 105 47.6 159 72.1 56 25 4 ow-Abobismrsi 048 142 64.4 106 48 1 162 73 5 60 27.2 1 060 150 68 0 115 52.2 160 72.6 65 29 5 CONDENSER COIL I 072 165 74 8 136 61 7 200 90 7 64 29 0 2'-9 5/16" [846.5)BOTTOM 3 I IV 2'-fi45/16- "Weights are for unit only(aluminum plate fins)and do not include options or crating OF UNIT I ) I BOTTOM POWER CHART,THESE CONNECTION SIZES HOLES REQUIRED FOR USE WITH A 1Y."Dia.[27)Field Power BTMACCESSORY PACKAGES— CRPWROO1A00('/a" 3/4") a"= mum I Supply Hole CRBTMPWROO2A00(/",1W) :I -IM • :A'' RAIL 1 B 3/n"—14 NPT Condensate 0'-4 •/t6" 3'-5 3/16' FLUE HOOD Drain THREADED REQUIRED TYP Ci tS B] 110461 0'-2 9/16' C W-14 NPT Gas Connection CONDUIT WIRE SIZE HOLE SIZES SIZE (MAX) [651 LEFT SIDE w 24 V Ye"[222 /n" Powe 1/e"[28 4 a t 13/4" Powerf 1 W[44 4 REAR OUTDOOR AIR LED VIEW MOLE (Select either 3/4"or 11/4"for power,depending C V(�V((�/ on wire size N 3'-1 1/2' S 2'-0 15/I6" 5,_0'-4 i/2' CHANNEL FOR 24V 0,-y/4• FILTER ACCESS PANEL [952.51 �['""" [633] �t (1141 CONTROL WIRING I [221 (THROWAWAY FILTERS) CONDENSER COIL 1 --• ABLOCKOFF COMPRESSOR— ECONOMIZER HOOD PANEL I • CORNER ACCE55 COVER 1 -4 3/B" Lai' 31/16" I` A [4161 • • • SEE NOTE •8 -1/CORNER "8' Ell ) r t I 2'-] 11/16" +0"-3 3/16" / I [652) l [BI] L_o'_5/16' • LEFT I 1 ` VIEW A-A SIDE III I RETURN-AIR OPENING 11 0.-10 115/16" RETURN AIR 0 O O EJ II VERTICAL I I [2781 111 © + I .-0'-5 3/8" VIEW 5-5 /�/ III . ' I. � 1 [137) • 3 -9' II) 8 RIGHT SIDE 11144) III /. , I �� 111 '/i/ I Bf I I 29,16 ,. 1�` •/ ,ALT. CONDENSATEppppI 1 I 17[16?/16- „ , 651 2'-1/2' II 1'-B 1/8' //[76 2) IINABASEPAN ING / ISUPPLY-AIR I 1'-5 3/4' ///��, SUPPLY AIR I' 1512 4] / I EVAPORATOR OPENING [451) 16221 II SEE_ ,/ I COIL I VERTICAL I I 11 IEW A -A// L 0-1[491/16' L____1 I Q _ I1, 33._ 0'-3 S/16' _moi / 1105 0” 1jj- [99.4]0 [138]16 26. 11 SEE BOTTOM POWER SUGGESTED ELECTRICAL CORNER 'D" CHART(ELEC ONLY FRONT f DISCONNECT LOCATION I CONTROL BOX ACCESS PANEL O'-3 1/16.1.. '-0 1/1§1. 0'-3 3/16 CORNER 'C" i 2'-I1 11/16" [78] [306] '-(1311 • [9061 6'-1 11/16' 0'-7 1/4- '' (18721 " [184] 1'-5 5/16' 1 -Is 13/16" 0-4 1/16' 0'-0 3/8' 1439.7] I [274 6) [103 2) • 2'-575/16" FILTER ACCESS PANEL ' [ 14) [101 . ���� (THROWAWAY FILTERS) CONTROL BOX ACCESS �' -POWER/CONTROL POACCESS PANE WIRE - PANEL ACCE55 PANEL I �_ 1 I II =A4111111IIIIt- I I I 2'-1 11/16" �,I ) 6 7/16' 1 I HOOD FILTER (467 81 I REAIIRN- 1652 51 / I I AIR I OPENING EVAPORATOR-FAN MOTOR r I MORI il..—Fr.. I" AND I 1 I ZONTAL 1 1 I/4- BLOWER ACCESS PANEL 10•_11 7/0" 1 1 I // � 335 6) I SUPPLY-AIR 7' 1 [301 61 OPENING I [177 81 1 II./ _—I� 91 O1 5/16" I I HORIZONTAL I L- - 1 OUTDOOR AIR I I _J16 I�00 �� 00 I. • i - [20+21 2[746327"/ FORKLIFT TRUCK SLOTS 0'-5 3/4'� j '-1 15/16' /. )0'-5 II/16- 0'-7 3/8" [1461 ./ [658 6] / [144 3] 0'-2 1/4"DIA BURNER ACCESS [188 O] [571 W7 IDE SUPPLY AIR RETURN AIR PANEL FRONT (TYP B PLACES) OF PANEL B SID CONDENSATE DRAIN G H T SIDE NOTES: c Condenser coil,for proper airflow,36 in one side,12 in the other The side get- 1 Dimensions in I J are in millimeters ting the greater clearance is optional d Overhead,60 in to assure proper condenser fan operation. 2 jW, Center of gravity a Between units,control box side,42 in per NEC(National Electrical Code) f Between unit and ungrounded surfaces,control box side,36 in per NEC • 3 C. Direction of airflow g Between unit and block or concrete walls and other grounded surfaces,control I.1(0 box side,42 in per NEC 4 On vertical discharge units,ductwork to be attached to accessory roof curb only h Horizontal supply and return end,0 inches For horizontal discharge units,field-supplied flanges should be attached to horizon- 8 With the exception of the clearance for the condenser coil and combustion side as tat discharge openings,and all ductwork should be attached to the flanges stated in Notes 5a,b,and c,a removable fence or barricade requires no clearance. 5 Minimum clearance(llocal codes or jurisdiction may prevail): 7 Units may be installed on combustible floors made from wood or Class A,B,or C •• a Between unit,flue side and combustible surfaces,36 inches roof covering material if set on basereil. b Bottom of unit to combustible surfaces(when not using curb),1 inch Bottom of 8 The vertical center of gravity is 1'-6"[457]up from the bottom of the base rail Hon- base rail to combustible surfaces(when not using curb)0 inches zontal center of gravity is shown 17 0127 • ACCESSORY DIMENSIONS ROOF CURB UNIT SIZE "0"ALT "A" UNIT SIZE " " CONNECTOR r ACCESSORY 580D 680D „B,. ` "C„ DRAIN HOLE GAS , POWER CONTROL PKG ACY CRRFCESSOR A00 1'-2"[356] CRRFCURBOO2A00 2'-0"[610] 036-072 3/+'NPT 3/a"NPT 1/z"NPT "CRBTMPWROO1A00' 1'-91Y16" 1'-4" (Thru-The-Bottom) 036-072 [551] [406] 13/4"[45] 3/a'NPT 11/a"NPT /z"NPT CRBTMPWR002A00• (Thru-The-Bottom) 1 "Either connector package available for either roof curb C NOTES: f• 1 Roof curb accessory is shipped unassembled ,-———-h 2 Insulated panels 4 / 3 Dimensions in[ ]are in millimeters t s� 4 Roof curb: galvanized steel � tom'A / ' -. 5 Attach ductwork to curb (flanges of duct rest on C i % 3 • curb) r ‘,v:„ ———T 6 Service clearance 4 ft on each side I r ti Iii p� ( ` A, 7 "`[� Direction of airflow ^ 0 06) 1 GASKET 75) B (SUPPLIED 1/1711 CUSS I URN-AIR WIT ENING 2•-7 s/e' OP0'-0 1/,'(71 i 18031 )7/i/ NAIL 1 -1 7/16' I OPENING R C j TYPICAL (4) 510E5 •�- (3,11 I f %� 0'-7/I6' In I- I -- I111 COUNTER FLASHING + 1 Iy 1 — _-- pUC� IFIELD SUPPLIED) f 'I _^ '� f (FIELD SINPLIED) IAO FELT 0'-0 7/16' 1 I (FIELD SUPPLIED) (111 '-7 13/16' El' 1/6' 0-0 7/16' (BOLT HEADS) (504) (334) ' III) \ CANT STRIP SECTION "C-C"O-3' (BOLT HEADS) \ (FIELD SUPPLIED) SCALE 1,, (763 •� ROOFING MATERIAL 0'-O 7/16' 3'-0' 0'-0 7/16' '• (FIELD SUPPLIED) I; 0 A (BOL7 HEADS) (811 (`BOLT HEADS) A \ OPENING FOR BASEPAN ENTRY SERVICE 0-7 3/15 RIGID INSULATION (1831 (FIELD SUPPLIED) 09314' 01011, 033/16' (1I�18 SEE NOTE 42 � a / O [106]6 O. • • • 44/1111100 • / GAS / SERVICE / PLATE 1 -4 13/16' 0.-0 1/4'171 ©1116 • (427) I � r_ _ /• (INSIDE) , • p /01;;;Ifiiiii, ullg ' e lirI; 0 SIPPLY AIR RETURN AIR% / T2P3/0' \N. 611 VIEW `A-A" �� ' 1 MEAD OF BOLI TO BE ON O. INSIDE OF FLANGE 0 O'4 7/e' 11111( 25 ''1k S(1-77051 I/8' f+ \ 1� A ' 3-0 15/16• 1 1400 p 9- [939] ' ' VIEW "B" Y/ (TW ALL CORNERS) SEE VIEW "a"-A-- Roof Curb—580D036-072 21 :.::'k tea:{:i.ii''$i*.ni-v % .v . .,1{:::.. ::0:i::',•:ayy:o-: ?>:{ :::.:ii:i:;i;;^•.i`{•v';�;•:EC A* :{+,••.,�n..'. • Air ConPayneditioning , a < ,< �/ : yV •. . s.. -.,•m,_4•:."*,,,.,...tk =-zmak . W { . • ` . • t .. .:`is:Y ti s :7.MM ,• kN es ;{{ gG ... ,. •."Jr`.:*i;: { : ti eration.Vibration isolation provides quiet operation. Rotary, re- ciprocating,or scroll compressors are used.Compressors have :‘k internal high-pressure and overcurrent protection. DIRECT-DRIVE MULTISPEED,PSC(permanent split capac- itor)BLOWER MOTOR is standard on all models. DIRECT-DRIVE, PSC CONDENSER-FAN MOTORS are de- signed to help reduce energy consumption and provide for cool- =I ing operation down to 40 F. s, REFRIGERANT SYSTEM is designed to provide dependability. �' Liquid refrigerant strainers are used to promote clean, unre- stricted operation. Each unit leaves the factory with a full refrig- erant charge. Refrigerant service connections make checking operating pressures easier. EVAPORATOR AND CONDENSER COILS are computer- DESCRIPTIONdesigned for optimum heat transfer and cooling efficiency.Con- All 588A models feature one piece, compact design and are denser coil is fabricated of copper tube and aluminum fins and fully self-contained units that are prewired, prepiped, and pre- is located inside the unit where it is protected against damage , charged for minimum installation expense. Unit is designed for for long life and reliable operation. easy use in either downflow(vertical)or horizontal applications. Copper fin coils are also available by special order.These coils Models are available in a variety of standard and optional are recommended in applications where aluminum fins are heating/cooling size combinations with voltage options to meet likely to be damaged due to corrosion. Ideal for seacoast residential and light commercial requirements. These units in- applications. stall easily on a rooftop or a ground-level pad. MONOPORT INSHOT BURNERS produce precise air-to-gas III mixture,which provides for clean and efficient combustion.The STANDARD FEATURES large monoport on the inshot(or injection type)burners seldom, FACTORY-ASSEMBLED PACKAGE is a compact, fully self- if ever, needs cleaning. contained,gas heating/electric cooling unit that is prewired,pre- WEATHERIZED CABINETS are constructed of heavy-duty, piped, and precharged for minimum installation expense. phosphated,zinc-coated prepainted steel capable of withstand- 588A units are available in a variety of standard heating and ing 500 hours in salt spray. Interior surfaces of the evaporator cooling sizes with voltage options to meet residential and light compartment are insulated to help keep the conditioned air commercial requirements. Unit installs easily on a rooftop or a from being affected by the outdoor ambient temperature. ground-level pad. LOW SOUND RATINGS ensure a quiet indoor and outdoor en- CONVERTIBLE DUCT CONFIGURATION on the 588A is de- vironment with sound ratings as low as 7.4 bels. signed for easy use in either downflow or horizontal discharge EASY TO SERVICE CABINETS provide easy accessibility to applications. serviceable components during maintenance and installation, HIGH-EFFICIENCY DESIGN with SEERs (Seasonal Energy Rounded corners are an important safety feature, and a high- Efficiency Ratios)of 10.0. quality finish ensures an attractive appearance. _ DURABLE,DEPENDABLE COMPRESSORS are designed for RIGGING BRACKETS are available to facilitate easy lifting and high efficiency. Each compressor is hermetically sealed against placement of the unit. contamination to help promote longer life and dependable op- 0 Form No. PDS 588A.18.3P ARI CAPACITIES UNIT 588A NOMINAL STANDARD NET COOLING* SOUND RATINGS** SEER*t TONS CFM CAPACITIES(Btuh) (Bels) • 018 1' 600 17,000 10 0 7 4 024 2 800 24,000 10.0 7 6 030 21/2 1000 29,200 10 0 8 0 - 036 3 _ 1200 36,000 10 0 8.0 042 31/2 1400 42,500 10 0 8.0 048 4 1600 47,000 10.0 8.2 060 5 1995 59,500 10.0 8.2 LEGEND NOTE: Ratings are net values, reflecting the effects of circulating fan db - dry bulb heat Ratings are based on 80 F db,67 F wb indoor entering-air tern- SEER - Seasonal Energy Efficiency Ratio perature and 95 F db air entering outdoor unit. wb - wet bulb *Rated In accordance with U S.Government DOE(Department of En- ergy)test procedures and/or ARI (Air Conditioning and Refrigeration �� Institute)Standard 210/240-89. ,� time-delayrelay 1 tAll units have factory-installed y **Rated in accordance with ARI Standard 270-84. *"*a"" HEATING CAPACITIES AND EFFICIENCIES HEATING INPUT OUTPUT CAPACITY TEMPERATURE AFUE(%) CSE(%) UNIT 588A (Btuh) (Btuh) RISE RANGE(°F) 018040 20-50 81.0 76.5 024040 40,000 32,800 20-50 81.0 76 5III 030040 20-50 81.0 76.5 024060 25-55 810 77.5 03006060,000 48,600 25-55 81.0 77.5 036060 25-55 81.0 77.5 042060 25-55 81.0 77 5 030080 40-70 81 0 77 5 036080 40-70 81 0 77 5 042080 80,000 64,800 40-70 810 77.5 048080 40-70 810 77.5 060080 40-70 81.0 77.5 036100 50-80 810 78.0 042100100,000 gi 0pp 50-80 81 0 78 0 048100 50-80 810 78.0 060100 50-80 81 0 78.0 036120 60-90 80 0 77.5 042120120,000 97,200 60-90 80.0 77 5 048120 60-90 80.0 77 5 060120 60-90 80.0 77.5 048140136,000 110,160 50-80 80 0 77 5 060140 50-80 80 0 77.5 LEGEND AFUE - Annual Fuel Utilization Efficiency CSE - California Seasonal Efficiency (----: NOTE: Before purchasing this appliance, read important energy cost I and efficiency information available from your retailer. �= T UArrRovro eL • ill..-- 4 DIMENSIONAL DRAWINGS COND COIL I,- (124 0 6) la 43 11/16' / a (1108 BA. ) 9� g 111 , 0 1 H I „ • 1 1305 0) I. \- • EV COIL 1--"`• ' . ../. - • \ A .i a �I IiI:.V „I: - OPTIONAL RETURN AIR OPENING BLOWER ACCESS 1—" '7// /a PANEL BURNER ANO CONTROL BOX 49 9/16' CG/// I RETURN ACCESS PANEL (1259 3) //( 1 14 7/16- RIGHT 510E VIEW I I (365 9) IL___ I I+ I NOTES: X 1 Clearances must be maintained to prevent recirculation of air from outdoor • fan discharge,with the exception of the condenser coil as stated.A remov- I I Ile I t2 7 s> able fence or barricade requires no clearance I 10 9/16 (Ss) 2 Dimensions in()are in mm 1 I iii SUPPLY (268 9) f i A NEC REQ'D CLEARANCES. I, 1 ` i y I'-0 1 13/16' IN.(mm) A LJ (46 2) 6 5/8+ 1 11/16' Between units,control box side . 42(1066 8) 6 5 1) J —11 1/16- (43 2) Unit and ungrounded surfaces,control box side. 36(914 4 (75 7) (281 4) Unit and block or concrete walls and other grounded surfaces,control box side . 42(1066 8) Y j 1(433 1 ~, 9) L OPTIONAL SUPPLY REQ'D CLEARANCES FOR SERVICING REQ'D CLEARANCES TO COMBUSTIBLE MATL. AIR OPENING 1N.(mm) IN.(mm) Duct Panel . . . . . 6152 4 Maximum Extension of Overhangs .48(1219 2) Unit Top . . . 38(914 4) Unit Top . 14(355 6) Side Opposite Ducts . . . 36914 4 Duct Side of Unit . 0 Compressor Access . . . 36(914 4) Side Opposite Ducts . 9(228 6) (Except for NEC Requirements) Bottom of Unit . . . . . .0 Flue Panel . . . 30(762 0) COMPRESSOR ACCESS PANEL 7!8' (22.2) DIA EVAP COIL ACCESS CONTROL ENTRY I 1/B' (28 6) DIA FLUE HOOD POWER ENTRY ' - -_•_ I 'iLl' •113/16 ��IF m =illJ' • 16 9/16" I =(420 9) 4 3!16 18 1/16'(106 2) (45B B) I6(80.91I(�A 2 I� , .- . ..1111•GAS ENTRY. 3) DIA (513 0) y1 1 8 \-3/4' NPT DRAIN OUTLET 10) 1/2' - 14 NPT 13/16++ x-14 1/16'-. GAS CONNECTION (29 6) 17/11 -J FLUE PANEL 10'+ 1357 2) (36 3) 2 3/16' (253 84,6 3/4'� (55 6) (171 7) REAR VIEW LEFT SIDE VIEW FRONT VIEW ELECTRICAL UNIT WEIGHT CORNER WEIGHT(Ib/kg) UNIT HEIGHT(In./mm) UNIT CHARACTERISTICS _ lb kg A B C D E 588A018040 208/230-1-60 272 123 81/37 62/28 76/35 53/24 24 12/612 8 588A024040 208/230-1-60 303 138 97/44 43/20 123/56 40/18 24 12/612 8 588A024060 208/230-1-80 315 143 100/45 46/21 126/57 43/20 24 12/612 8 588A030040 208/230-1-60,208/230-3-60 320 145 100/45 47/21 126/57 47/21 24 12/612 8 588A030060 208/230-1-60,208/230-3-60 324 147 94/43 63/29 115/52 52/24 24 12/612 8 588A030080 208/230-1-60,208/230-3-60 324 147 94/43 63/29 115/52 52/24 24 12/612 8 588A036060 208/230-1-60,208/230-3-60,460.3-60 336 153 86/39 76/35 111/50 63/29 24 12/612 8 588A036080 208/230-1-60,208/230-3-60,460-3-60 336 153 86/39 76/35 111/50 63/29 24 12/612 8 588A038100 208/230-1-60,208/230-3-60,460-3-60 348 158 89/40 79/36 114/52 66/30 24 12/612.8 588A036120 208/230-1-60,208/230-3-60,460-3-60 348 158 89/40 79/36 114/52 66/30 24 12/612 8 588A042060 208/230-1-60,208/230-3-60,460.3-60 375 170 95/43 86/39 119/54 75/34 24.12/6128 588A042080 208/230-1.60,208/230-3-60,460-3-60 375 170 95/43 86/39 119/54 75/34 28.12/714 2 588A042100 208/230-1-60,208/230-3-60,460-3-60 387 176 98/45 89/40 122/55 78/35 28.12/7142 588A042120 208/230-1-60,208/230-3-60,460-3-60 387 176 98/45 89/40 122/55 78/35 28 12/714 2 UNIT CENTER OF GRAVITY(In./mm) UNIT CENTER OF GRAVITY(In./mm) X Y Z X Y Z 588A018040 25 07/637 20 59/523 10.85/276 • 588A036080 27 50/698 22 48/571 10 85/276 588A024040 27.07/688 23 35/593 10.85/276 588A036100 27 40/696 22 44/570 10 85/276 S 588A024060 26.98/685 23 27/591 10 85/276 588A036120 27.40/696 22 44/570 10 85/276 588A030040 26 71/678 23 46/596 10 85/276 588A042060 27 01/686 22.44/570 12 65/321 588A030060 27 15/689 22 36/568 10.85/276 586A042080 27.01/686 22 44/570 12 65/321 588A030080 27.15/689 22 36/568 10 85/276 588A042100 26 94/684 22 44/570 12 65/321 588A036060 27 50/698 22 48/571 10.85/276 588A042120 28.94/684 22.44/570 12 65/321 CG — Center of Gravity Unit 588A, Sizes 018-042 5 SPECIFICATIONS UNIT SIZE 588A 018040 024040 024060 030040 030060 030080 NOMINAL CAPACITY (tons) 1 2 2 2'. 2' 0 OPERATING WEIGHT(Ib) 272 303 315 320 324 324 COMPRESSOR Role y Reciprocatinn Quantity 1 1 REFRIGERANT R-22 Charge(Ib) 2.60 2 75 2.75 3.40 3.40 3.40 Fixed Restrictor CONDENSER COIL Face Area(sq ft) 5 95 5 95 5 95 5.95 5.95 5.95 Rows...Fins/in. 1..17 1. 17 1..17 2..17 2...17 2. 17 CONDENSER FAN Nominal Airflow(cfm) 1700 1700 1700 1900 1900 1900 Nominal Speed(rpm) 850 850 850 850 850 850 Quantity...Diameter(in.) 1..18 1. 18 1 18 1 18 1 .18 1 18 Motor Hp 1/8 1h 1/8 1/4 V4 1/4 EVAPORATOR COIL Face Area(sq ft) 1.83 2 29 2 29 2.29 2 29 2 29 Rows...Fins/In. 3..15 3. 15 3 15 3.15 3 15 3 .15 EVAPORATOR FAN Nominal Airflow(cfm) 600 800 800 1000 1000 1000 Nominal Speed(rpm) 825 1025 1025 1025 1025 1025 Diameter x Width(In.) 10x10 10x10 10x10 10x10 10x10 10x10 Motor Hp(single-phase) 1/4 1/4 1/4 1/4 1/4 1/4 three •hese) - - - 1/4 1/4 1/4 FURNACE SECTION Burner Orifice No. (Qty...drill size) 1...32 • 1. 32 2...38 1 ..32 2 38 2 32 Natural Gas Burner Orifice No. (Qty...drill size) 1 .49 1..49 2...52 1 ..49 2..52 2. 49 Propane Gas RETURN-AIR FILTERS 20 x 20 20 x 20 20 x 20 20 x 24 20 x 24 20 x 24 40 UNIT SIZE 588A 036060 036080 036100 042060 042080 042100 NOMINAL CAPACITY(tons) 3 .. 3 3 3'_ 3 . OPERATING WEIGHT lb 336 336 348 375 375 387 COMPRESSOR Reciprocating Quantity 1 Gitiiiiii RANT R-22 4 30 4.30 4 30 5.20 5 20 5.20 REFRIGERANT METERING DEVICE Fixed Restrictor CONDENSER COIL Face Area(sq ft) 5.95 5 95 5 95 7.04 7.04 704 Rows...Fins/in. 2 .17 2 17 2..17 2..17 2..17 2...17 CONDENSER FAN Nominal Airflow(cfm) 1900 1900 1900 1900 1900 1900 Nominal Speed(rpm) 1050 1050 1050 1050 1050 1050 Quantity...Diameter(In.) 1 18 1 .18 1...18 1 ..18 1..18 1 18 Motor Hp 1/4 1/4 1/4 1/4 1/4 1/4 EVAPORATOR COIL Face Area(sq ft) 3 06 3 06 3.06 3.61 3.61 3.61 Rows...Fins/in. 3. 15 3..15 3..15 3...15 3...15 3. 15 EVAPORATOR FAN ' Nominal Airflow(cfm) 1200 1200 1200 1400 1400 1400 Nominal Speed(rpm) 1100 1100 1100 1100 1100 1100 Diameter x Width(in.) 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 Motor Hp(single-phase) V2 V2 1/2 3/4 3/4 3/4 (three-phase) 1/2 1/2 1/2 3/4 3/4 3/4 FURNACE SECTION Burner Orifice No. (Qty...drllI size) 2..38 2 32 3..35 2..38 2 32 3..35 Natural Gas Burner Orifice No. (Qty...drill size) 2..52 2.49 3...52 2. 52 2 49 3...52 Propane Gas RETURN-AIR FILTERS(In.)' ( Throwaway 20 x 24 20 x 24 20 x 24 24 x 24 24 x 24 24 x 24 *Required field-supplied filter sizes are based on the larger of the ARI-rated(Air Conditioning&Re- frigeration Institute)cooling airflow or the heating airflow at a velocity of 300 ft/min for throwaway type Air filter pressure drop must not exceed 0.08 in wg 9